<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-6230</journal-id>
<journal-title><![CDATA[Revista Facultad de Ingeniería Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev.fac.ing.univ. Antioquia]]></abbrev-journal-title>
<issn>0120-6230</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería, Universidad de Antioquia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-62302008000100009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseño de un sistema piloto para el estudio de la corrosión del material de tubería y su contribución en el deterioro de la calidad del agua potable]]></article-title>
<article-title xml:lang="en"><![CDATA[Design of a model system for the study of corrosion of pipe material and its contribution in deterioration of drinking water quality]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rios]]></surname>
<given-names><![CDATA[John Fredy]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Calderón]]></surname>
<given-names><![CDATA[Jorge Andrés]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[Félix]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Peñuela]]></surname>
<given-names><![CDATA[Gustavo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Grupo de Corrosión y Protección ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Grupo de Diagnóstico y Control de la Contaminación ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2008</year>
</pub-date>
<numero>43</numero>
<fpage>102</fpage>
<lpage>113</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-62302008000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-62302008000100009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-62302008000100009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los sistemas de distribución pueden afectar la calidad del agua potable debido a las condiciones de la tubería y a la operación del sistema. Algunos parámetros son sensibles a la variación durante la distribución como: el cloro residual, pH, color y turbiedad, debido a que el material de la tubería puede presentar deterioro en estos sistemas a causa de la corrosividad del agua. Los diversos estudios realizados sobre el tema han empleado tanto sistemas reales como dispositivos de laboratorio para la realización de los ensayos. Entre los dispositivos más empleados actualmente, se reporta el uso del sistema piloto de distribución por las ventajas que ofrece y su flexibilidad en el diseño. Para definir las características de diseño de un sistema piloto de distribución se hizo una revisión de la literatura. El sistema se empleará en el estudio de la interacción entre el líquido y la pared de tubería. Se utilizarán materiales metálicos usados en sistemas de distribución secundarios, con el fin de determinar el ataque a la superficie interna de las tuberías y las causas de formación de depósitos sobre ellas, así como identificar los efectos de esta interacción en la calidad del agua.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Distribution systems can affect drinking water quality because pipe conditions and system operation. Some parameters like residual chlorine, pH, color and turbidity can be modified during the distribution, because pipe material can show deterioration in these systems by the water corrosivity. Several studies about this topic had used both real system and laboratory equipment for performing of tests. The most used apparatus nowadays is the model distribution system; it has several advantages like flexibility and easiness for design. A revision in journals is used for defining the design characteristics of model distribution system. It will be used for studying the interaction between the water and the pipe wall. Metallic materials used in secondary distribution system will be used in this study with the purpose of determining the attack to the inner surface of pipes and the causes of deposits formed on them; such as identifying the effects of this interaction in water quality.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[sistema piloto de distribución]]></kwd>
<kwd lng="es"><![CDATA[agua potable]]></kwd>
<kwd lng="es"><![CDATA[corrosión en tubería]]></kwd>
<kwd lng="es"><![CDATA[biopelícula]]></kwd>
<kwd lng="en"><![CDATA[model distribution system]]></kwd>
<kwd lng="en"><![CDATA[drinking water]]></kwd>
<kwd lng="en"><![CDATA[pipe corrosion]]></kwd>
<kwd lng="en"><![CDATA[biofilm]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="center"><font face="Verdana" size="4"><b>Dise&ntilde;o de un sistema piloto para el estudio de la corrosi&oacute;n del material de tuber&iacute;a y su contribuci&oacute;n en el deterioro de la calidad del agua potable</b> </font> </p>     <p align="center">&nbsp;</p>     <p align="center"><font face="Verdana" size="4"><b>Design of a model system for the study of corrosion of pipe material and its contribution in deterioration of drinking water quality </b> </font></p> <font face="Verdana" size="2">  </font>    <p><font face="Verdana" size="2"><i>John Fredy Rios<sup>a</sup>, Jorge Andr&eacute;s Calder&oacute;n<sup>a*</sup>, F&eacute;lix Echeverr&iacute;a<sup>a</sup>, Gustavo Pe&ntilde;uela<sup>b</sup></i> </font> </p>     <p><font face="Verdana" size="2">a Grupo de Corrosi&oacute;n y Protecci&oacute;n, Universidad de Antioquia, Lab 330, Torre 2, SIU, Calle 62 N&ordm; 52-59, Medell&iacute;n, Colombia. </font> </p>     <p><font face="Verdana" size="2">b Grupo de Diagn&oacute;stico y Control de la Contaminaci&oacute;n, Universidad de Antioquia, Lab 232, Torre 2, SIU, Calle 62 N&ordm; 52-59, Medell&iacute;n, Colombia.</font></p>     <p><font face="Verdana" size="2">&nbsp;</font></p>     <p><font face="Verdana" size="2">&nbsp;</font></p> <hr noshade size="1">     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Resumen</b></font></font>  </p>     <p><font face="Verdana" size="2">Los sistemas de distribuci&oacute;n pueden afectar la calidad del agua potable debido a las condiciones de la tuber&iacute;a y a la operaci&oacute;n del sistema. Algunos par&aacute;metros son sensibles a la variaci&oacute;n durante la distribuci&oacute;n como: el cloro residual, pH, color y turbiedad, debido a  que el material de la tuber&iacute;a puede presentar deterioro en estos sistemas a causa de la corrosividad del agua. Los diversos estudios realizados sobre el tema han empleado tanto sistemas reales como dispositivos de laboratorio para la realizaci&oacute;n de los ensayos. Entre los dispositivos m&aacute;s empleados actualmente, se reporta el uso del sistema piloto de distribuci&oacute;n por las ventajas que ofrece y su flexibilidad en el dise&ntilde;o. Para  definir las caracter&iacute;sticas de dise&ntilde;o de un sistema piloto de distribuci&oacute;n se hizo una revisi&oacute;n de la literatura.       El sistema se emplear&aacute; en el estudio de la interacci&oacute;n entre el l&iacute;quido y la pared de tuber&iacute;a. Se utilizar&aacute;n materiales met&aacute;licos usados en sistemas de distribuci&oacute;n secundarios, con el fin de determinar el ataque a la superficie interna de las tuber&iacute;as y las    causas de formaci&oacute;n de dep&oacute;sitos sobre ellas, as&iacute; como identificar los efectos de esta interacci&oacute;n en la calidad del agua. </font> </p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2"><strong>Palabras clave</strong>: sistema piloto de distribuci&oacute;n, agua potable, corrosi&oacute;n en tuber&iacute;a, biopel&iacute;cula.</font>  </p> <font face="Verdana" size="2">    <br> </font><hr noshade size="1">     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Abstract</b></font></font>  </p>     <p><font face="Verdana" size="2">Distribution systems can affect drinking water quality because pipe conditions   and system operation. Some parameters like residual chlorine, pH, color and turbidity can be modified during the distribution, because pipe material can show deterioration in these systems by the water corrosivity. Several studies about this topic had used both real system and laboratory equipment for performing of tests. The most used apparatus nowadays is the model distribution system; it has several advantages like flexibility and easiness for design. A revision in journals is used for defining the design characteristics of model distribution system. It will be used for studying the interaction between the water and the pipe wall. Metallic materials used in secondary distribution system will be used in this study with the purpose of determining the attack to the inner surface of pipes and the causes of deposits formed on them; such as identifying the effects of this interaction in water quality.  </font></p>     <p><font face="Verdana" size="2"><strong>Keywords</strong>: model distribution system, drinking water, pipe corrosion, biofilm.     <br></font> </p> <hr noshade size="1">     <p><font face="Verdana" size="2">&nbsp;</font></p>     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Introducci&oacute;n</b>  </font></font></p>     <p><font face="Verdana" size="2">Las empresas que prestan el servicio de agua potable son concientes de la variaci&oacute;n que puede sufrir la calidad del agua luego de abandonar la planta de tratamiento, principalmente ocasionado por las condiciones f&iacute;sicas del sistema de distribuci&oacute;n debido al tiempo de funcionamiento de la infraestructura y las condiciones de operaci&oacute;n hidr&aacute;ulicas. Son grandes los esfuerzos y los estudios realizados para dar soluci&oacute;n a los problemas presentados en la distribuci&oacute;n del agua que permitan disminuir el efecto negativo ocasionado a la calidad del agua. Las investigaciones realizadas al respecto son diversas y se enfocan en estudiar los cambios en la calidad del agua [1], las variables que favorecen o inhiben el deterioro de la tuber&iacute;a del sistema de distribuci&oacute;n y su correlaci&oacute;n con la p&eacute;rdida de material [2, 3, 4], la formaci&oacute;n de biopel&iacute;cula en la superficie de la tuber&iacute;a [5,6], la presencia de microorganismos en el agua potable [7], entre otros. Entre los dispositivos   empleados en los estudios se puede mencionar: el dispositivo de Robbins, de f&aacute;cil uso, empleado con algunas modificaciones para analizar el crecimiento de microorganismos [8,9] y monitorear el desarrollo en biopel&iacute;culas de bacterias causantes de problemas de corrosi&oacute;n en l&iacute;neas de tuber&iacute;a [10]; el dispositivo Pederson empleado con ligeras modificaciones por Momba para estudiar la formaci&oacute;n de biopel&iacute;cula en diferentes materiales met&aacute;licos y no met&aacute;licos [11,12]; el sistema de rototorque o reactor anular, el cual se compone de dos cilindros, uno exterior estacionario y uno interno rotatorio que permite variar la velocidad de rotaci&oacute;n para obtener el esfuerzo cortante en la pared m&aacute;s externa, correspondiente a la condici&oacute;n de flujo que se desea simular. Este sistema es bastante usado en investigaciones para estudiar la biopel&iacute;cula en las cuales se ubican l&aacute;minas del material de estudio en la cara externa del cilindro interno [13] o probetas del material en el cilindro externo [14]. Adicionalmente se han analizado los cambios en los par&aacute;metros del agua tomando muestras del agua a la salida [15]. Sin embargo, la relaci&oacute;n &aacute;rea superficial-volumen en el sistema rototorque es mayor que en las tuber&iacute;as por lo cual el tiempo de retenci&oacute;n en estos sistemas corresponde a mayores tiempos en un sistema de distribuci&oacute;n real [16]. Por &uacute;ltimo, se tiene el sistema piloto de distribuci&oacute;n, muy empleado en las investigaciones recientes debido a que permite obtener condiciones m&aacute;s reales de una red de distribuci&oacute;n de agua potable, debido a que la hidr&aacute;ulica y la relaci&oacute;n  superficie/volumen son m&aacute;s similares [17].</font>  </p>     <p><font face="Verdana" size="2"><b>Sistema piloto de distribuci&oacute;n</b> </font> </p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Los sistemas pilotos de distribuci&oacute;n tienen varias caracter&iacute;sticas que permiten su utilizaci&oacute;n en los estudios actuales y son los reactores m&aacute;s com&uacute;nmente usados para estudios de corrosi&oacute;n. Los mismos se han empleado para simular sistemas de distribuci&oacute;n de agua, ya sea s&oacute;los o en conjunto con cupones de ensayo o acoplados con investigaciones de planta piloto. Entre sus ventajas se tienen: las variables que afectan la corrosi&oacute;n pueden ser sistem&aacute;ticamente controladas y evaluadas; suministran datos acerca de la velocidad de corrosi&oacute;n del material, efectos de fluctuaciones o modificaciones de calidad del agua o tratamientos alternativos. Igualmente, se pueden emplear para estudios de recrecimiento microbiol&oacute;gico, an&aacute;lisis de biopel&iacute;cula, problemas de calidad de agua, entre otros. Eisnor [18] ha presentado una amplia revisi&oacute;n bibliogr&aacute;fica de sistemas pilotos de distribuci&oacute;n,   en la cual se especifican las variables del sistema en tres grupos, a saber: las caracter&iacute;sticas   f&iacute;sicas (material, di&aacute;metro y longitud de la secci&oacute;n de ensayo), las hidrodin&aacute;micas (configuraci&oacute;n de flujo, tiempo de retenci&oacute;n, velocidad de flujo y tiempo de estancaci&oacute;n) y las t&eacute;cnicas que aseguren la calidad (medici&oacute;n de la calidad del agua y duraci&oacute;n del estudio). Adicionalmente, se presenta una compilaci&oacute;n y discusi&oacute;n de los valores  empleados en diferentes estudios, lo cual permite una buena orientaci&oacute;n para el dise&ntilde;o y montaje de un futuro sistema. En los sistemas pilotos de distribuci&oacute;n es importante tener como base los objetivos del estudio para la definici&oacute;n de las caracter&iacute;sticas f&iacute;sicas, las condiciones hidr&aacute;ulicas, la duraci&oacute;n del ensayo, los an&aacute;lisis del agua y el material de tuber&iacute;a.   A continuaci&oacute;n se presentan algunos aspectos a tener en cuenta en sistemas pilotos utilizados en diferentes estudios, clasific&aacute;ndolos en las tres categor&iacute;as mencionadas. </font> </p>     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Caracter&iacute;sticas f&iacute;sicas</b> </font></font> </p>     <p><font face="Verdana" size="2">Considera esencialmente las variables relacionadas con la secci&oacute;n de ensayo empleada en el estudio como: el material, la longitud, el di&aacute;metro y el tramo de tuber&iacute;a. Los materiales seleccionados en los estudios normalmente son los utilizados en el sistema de distribuci&oacute;n hacia el cual va dirigido, pueden ser tuber&iacute;as de PVC, polietileno, hierro d&uacute;ctil con recubrimiento interno de cemento, fundici&oacute;n de hierro, acero al carbono, acero galvanizado o cobre. En varios casos las tuber&iacute;as utilizadas en el piloto provienen de un sistema de distribuci&oacute;n real [19]. La longitud de la tuber&iacute;a no  presenta un valor est&aacute;ndar. Cuando se tiene flujo de agua a trav&eacute;s del sistema con un solo paso, se emplean sistemas que tienen una longitud de tuber&iacute;a de varios metros, con el fin de incrementar el tiempo de contacto entre el agua y la pared de tuber&iacute;a. Para sistemas donde la velocidad de flujo utilizada es muy baja, la longitud de tuber&iacute;a es aproximadamente de 30 m [19,20], aunque se han reportado sistemas con longitudes de hasta 100 m [21]. Para sistemas en los cuales se tiene   recirculaci&oacute;n del agua, la longitud de tuber&iacute;a empleada normalmente es de 1,5 m [22,23], pero se han empleado sistemas con longitudes de hasta 27 m [24]. Adicionalmente, se han utilizado tramos cortos de tuber&iacute;a para analizar la formaci&oacute;n de dep&oacute;sitos [25] o la acumulaci&oacute;n de biopel&iacute;cula a lo largo del ensayo [26], los cuales presentan una longitud menor a 0,30 m.</font>  </p>     <p><font face="Verdana" size="2">El di&aacute;metro de la tuber&iacute;a empleado en los estudios no presenta un valor &uacute;nico, sin embargo reportes de la literatura presentan l&iacute;neas de tuber&iacute;a con di&aacute;metros inferiores a 0,15 m e incluso aun menores a 0,025 m de di&aacute;metro para sistemas que eval&uacute;an materiales empleados en redes de edificaciones. Algunos estudios han empleado sistemas que se componen de varios materiales provenientes de l&iacute;neas de sistemas de distribuci&oacute;n, empleando tuber&iacute;as de 0,15 m de di&aacute;metro, excepto en el caso del acero galvanizado con 0,05 m de di&aacute;metro [19,20]. Para el caso de tuber&iacute;a de cobre, el di&aacute;metro reportado ha sido menor, alrededor de 0,001 m [21]. La tuber&iacute;a evaluada puede conformarse de varios tramos cortos unidos continuamente o la exposici&oacute;n de tramos largos.   Los tramos cortos de tuber&iacute;a han sido empleados cuando se desea evaluar la superficie interna del material de tuber&iacute;a, especialmente deterioro y formaci&oacute;n de biopel&iacute;cula. Percival [27] evalu&oacute; el desarrollo de biopel&iacute;cula en la superficie de aceroinoxidable. En este estudio la secci&oacute;n de ensayo se compone de peque&ntilde;os tramos de tuber&iacute;a unidos continuamente, permitiendo insertar y evaluar el material de estudio. Por otro lado, los tramos largos se emplean para evaluar las variaciones en los par&aacute;metros del agua y la disoluci&oacute;n de especies   desde la superficie interna del material de tuber&iacute;a, mediante un frecuente muestreo del agua.  </font></p>     <p><font face="Verdana" size="2"><b>Condiciones hidr&aacute;ulicas</b> </font> </p>     <p><font face="Verdana" size="2">Dentro de las condiciones hidr&aacute;ulicas del sistema se consideran: la velocidad de flujo, el tiempo de retenci&oacute;n y la configuraci&oacute;n de flujo del fluido en la secci&oacute;n de ensayo. La velocidad de flujo empleada en los estudios se elige seg&uacute;n las condiciones a simular. Cuando el objetivo del estudio contempla condiciones de flujo normal, la velocidad de flujo es 0,3 m/s. Si se trata del an&aacute;lisis en zonas con estancamiento o en puntos terminales, normalmente la velocidad de flujo empleada es  muy inferior a este valor, alrededor de 0,042 m/s [22,28] o menor.  </font></p>     <p><font face="Verdana" size="2">El tiempo de retenci&oacute;n es bastante importante ya que algunos par&aacute;metros del agua cambian apreciablemente con pocas horas de retenci&oacute;n como es el caso del ox&iacute;geno disuelto y del cloro residual. Sin embargo, para simular condiciones de puntos muertos algunos estudios han empleado tiempos de retenci&oacute;n de varios d&iacute;as [29]. Se ha reportado que en sistemas reales la disminuci&oacute;n de estos es demasiado alta luego de 1,5 d&iacute;as; no obstante, en sistemas con recirculaci&oacute;n se ha reportado una disminuci&oacute;n en el oxigeno disuelto bastante elevada luego de 8 horas [22]. Espec&iacute;ficamente el tiempo debe ser elegido basado en el mayor tiempo de retenci&oacute;n del agua en el sistema de estudio. Para la recirculaci&oacute;n de flujo de agua   que presente una velocidad espec&iacute;fica, se ha reportado el tiempo de retenci&oacute;n a su equivalente en longitud de tuber&iacute;a [24].</font></p>     <p> <font face="Verdana" size="2">La configuraci&oacute;n de flujo del sistema presenta dos opciones, flujo de agua con un solo paso o con recirculaci&oacute;n. El tiempo de retenci&oacute;n en un sistema piloto de distribuci&oacute;n depende directamente de la velocidad del agua cuando opera con un solo paso del fluido a trav&eacute;s de este, es decir una renovaci&oacute;n continua de agua. Las dos variables se logran independizar cuando el sistema se opera con recirculaci&oacute;n del agua. En diferentes investigaciones se han empleado ambas configuraciones de flujo. Tang [20] utiliz&oacute; un sistema piloto para evaluar el efecto de la mezcla de aguas de diferentes fuentes sobre la calidad del agua en un sistema de distribuci&oacute;n. El sistema empleado present&oacute; un solo paso del flujo a trav&eacute;s de &eacute;ste, por lo cual la velocidad de flujo empleada fue muy baja para permitir un tiempo de retenci&oacute;n suficiente. Eisnor [23] evalu&oacute; el impacto de desinfectantes secundarios en el deterioro interno de la tuber&iacute;a y en la variaci&oacute;n de la calidad del agua, el sistema utilizado funciona mediante recirculaci&oacute;n con una velocidad de flujo de 0,3 m/s, considerada como la velocidad t&iacute;pica en los sistemas de distribuci&oacute;n. </font> </p>     <p><font face="Verdana" size="2"><b>Evaluaci&oacute;n del agua y el material</b></font>  </p>     <p><font face="Verdana" size="2">En general los sistemas pilotos empleados en las investigaciones no presentan un dise&ntilde;o est&aacute;ndar, estos permiten tomar muestras de agua a la entrada y salida del sistema, y en algunos casos en diferentes puntos cuando son sistemas abiertos [28, 30]. Por otro lado poseen generalmente un solo punto de muestreo cuando el sistema presenta recirculaci&oacute;n [23]. Los muestreos del agua se realizan generalmente con una frecuencia comprendida entre 1 y 3 veces por semana [19, 21, 30], aunque se han empleado toma de muestras mensualmente [26]. Los par&aacute;metros del agua generalmente evaluados en los muestreos son: la temperatura, pH, acidez, alcalinidad, dureza, turbiedad, color, ox&iacute;geno disuelto, conductividad, desinfectante residual, s&oacute;lidos totales, carb&oacute;n org&aacute;nico disuelto, heter&oacute;trofos totales, absorbancia 254 nm, sulfatos, cloruros, hierro, manganeso, entre otros. Estos par&aacute;metros se eval&uacute;an para determinar la agresividad del agua sobre los materiales met&aacute;licos empleados en las tuber&iacute;as y para analizar la calidad del agua en un sistema de distribuci&oacute;n. Adicionalmente, se han utilizado tiempos de muestreo del agua de pocas horas cuando el objetivo es evaluar el decaimiento del desinfectante [24] y el oxigeno disuelto en el agua [22] o incluso minutos para determinar las variaciones en los par&aacute;metros del agua cuando se efect&uacute;a un incremento en la velocidad de flujo [30]. </font> </p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">El muestreo de la biopel&iacute;cula formada en la superficie de la tuber&iacute;a se ha realizado en periodos ligeramente mayores, se ha reportado su ejecuci&oacute;n semanalmente [31] o mensualmente [32]. La biopel&iacute;cula formada en el interior del sistema se estudia mediante la remoci&oacute;n de peque&ntilde;as secciones de tuber&iacute;a. La evaluaci&oacute;n se realiza mediante el raspado y lavado de la superficie interior de la tuber&iacute;a o mediante la remoci&oacute;n por sonicaci&oacute;n, mientras su an&aacute;lisis generalmente se lleva a cabo empleando conteo de heter&oacute;trofos. </font> </p>     <p><font face="Verdana" size="2">Con relaci&oacute;n al tiempo del ensayo, el estudio normalmente se efect&uacute;a con una duraci&oacute;n cercana a 1 a&ntilde;o, o a&uacute;n mayor para el caso de evaluaci&oacute;n de la corrosi&oacute;n de los materiales met&aacute;licos y la formaci&oacute;n de biopel&iacute;cula en el sistema de distribuci&oacute;n, como es el caso del an&aacute;lisis de diferentes procesos de desinfecci&oacute;n en la formaci&oacute;n de biopel&iacute;cula [26] y la caracterizaci&oacute;n de los productos de corrosi&oacute;n formados [33]. Por otro lado, se han empleado unas pocas semanas cuando el objetivo del estudio ha sido valorar los cambios en la calidad del agua como respuesta a la variaci&oacute;n de velocidad de flujo [30]. </font> </p>     <p><font face="Verdana" size="2"><b>Adecuaci&oacute;n del sistema piloto</b></font>  </p>     <p><font face="Verdana" size="2">Antes de iniciar los estudios en el sistema piloto de distribuci&oacute;n, cuando se utilizan materiales que han estado previamente en operaci&oacute;n en sistemas de distribuci&oacute;n, es necesario destinar un tiempo adecuado para que los materiales de tuber&iacute;a puedan establecer un equilibrio con el agua empleada en el estudio; en caso de emplear materiales nuevos,   se debe realizar un proceso de desinfecci&oacute;n mediante una soluci&oacute;n de hipoclorito [34]. Por   otro lado, se efect&uacute;a peri&oacute;dicamente la operaci&oacute;n de lavado al sistema cuando se usan velocidades muy bajas o cuando opera con recirculaci&oacute;n del agua, para lo cual se emplean una velocidad y una cantidad especifica de agua cada vez que se renueva. El lavado es tambi&eacute;n necesario cuando el estudio comprende un desarrollo en varias fases en las cuales se presentan cambios en el tratamiento o desinfecci&oacute;n del agua.  </font></p>     <p><font face="Verdana" size="2">El tiempo requerido para que el sistema alcance condiciones estables antes de realizar las evaluaciones puede ser de varios meses, seg&uacute;n lo reportado en la literatura, como es el caso de 5 meses para un sistema compuesto de diferentes materiales de tuber&iacute;a [29], o tiempos aun superiores de hasta un a&ntilde;o para ensayos de desinfecci&oacute;n [21]. Por otro lado, el lavado de la tuber&iacute;a en un sistema piloto de distribuci&oacute;n se realiza con una velocidad de flujo mayor a la empleada en el estudio. Estudios que utilizan una velocidad de flujo relativamente baja, realizan el proceso de lavado generalmente a una velocidad de flujo de   0.3 m/s, con una cantidad de agua que comprende al menos entre 3 y 5 veces el volumen de la tuber&iacute;a. [20, 24,29].  </font></p>     <p><font face="Verdana" size="2">Como puede observarse, son numerosas las variables y especificaciones de dise&ntilde;o a tener en cuenta en la selecci&oacute;n de un sistema piloto para el estudio del deterioro de las tuber&iacute;as y de la calidad del agua potable que circula por las mismas. El objetivo del presente trabajo es exponer los par&aacute;metros m&aacute;s relevantes y recientemente reportados en la literatura, relacionados con la utilizaci&oacute;n de pilotos para simular condiciones de sistemas de distribuci&oacute;n de agua potable. Adicionalmente, sentar las bases para la selecci&oacute;n de las caracter&iacute;sticas de dise&ntilde;o de un sistema piloto de distribuci&oacute;n que permita estudiar la interacci&oacute;n entre el agua potable y el material de tuber&iacute;a. As&iacute; mismo, que permita evaluar el deterioro del material de tuber&iacute;a y su incidencia en el detrimento de la calidad del agua.  </font></p>     <p><font face="Verdana" size="2"><b>Dise&ntilde;o del sistema piloto</b> </font> </p>     <p><font face="Verdana" size="2">Un sistema piloto de distribuci&oacute;n es una herramienta &uacute;til para simular las condiciones en un sistema de distribuci&oacute;n de agua real, debido a que permite definir las condiciones hidr&aacute;ulicas en el sistema y obtener informaci&oacute;n de la calidad del agua, velocidad de corrosi&oacute;n y condiciones microbiol&oacute;gicas al interior de una tuber&iacute;a, bajo unas condiciones controladas. La configuraci&oacute;n de estos dispositivos var&iacute;a en los diferentes trabajos y no existe un dise&ntilde;o est&aacute;ndar, debido a la flexibilidad que permite su dise&ntilde;o. Sin embargo, su clasificaci&oacute;n se puede realizar por la configuraci&oacute;n de flujo, la cual puede ser a trav&eacute;s del sistema con un solo paso del fluido o por recirculaci&oacute;n, las cuales se presentan en la <a href="#tabla1">tabla 1</a>.   Dentro de la configuraci&oacute;n del montaje con recirculaci&oacute;n, se dispone de un tramo lineal de la tuber&iacute;a del material a evaluar, acoplado en ambos extremos a una l&iacute;nea de material inerte en la cual est&aacute; instalada una bomba de recirculaci&oacute;n. En el montaje pueden existir dos dise&ntilde;os diferentes, uno es el sistema completamente cerrado mientras el otro incluye adicionalmente un tanque de dep&oacute;sito, el cual permite una operaci&oacute;n m&aacute;s f&aacute;cil, pero le proporciona un tiempo de estancaci&oacute;n al agua.   Caracter&iacute;sticas principales de un sistema piloto   En el dise&ntilde;o del sistema piloto es necesario definir las caracter&iacute;sticas del material, las condiciones de operaci&oacute;n, los muestreos y la adecuaci&oacute;n del sistema a realizar. Por esto, es necesario establecer los materiales a evaluar, la longitud expuesta, el di&aacute;metro de la tuber&iacute;a, la velocidad de flujo, el tiempo de retenci&oacute;n, los muestreos y el an&aacute;lisis a realizar, con el fin de obtener el sistema m&aacute;s adecuado a los requerimientos del estudio espec&iacute;fico. Un resumen de las caracter&iacute;sticas de un sistema se presenta en la <a href="#tabla2">tabla 2</a>.  </font></p>     <p><font face="Verdana" size="2"><b>Tabla 1</b> Configuraciones de flujo en un sistema piloto  </font></p>     <p align="center"><font face="Verdana" size="2"><img src="/img/revistas/rfiua/n43/n43a09i01.gif"><a name="tabla1"></a></font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2"><b>Tabla 2</b> Caracter&iacute;sticas de un sistema piloto</font>  </p>     <p align="center"><font face="Verdana" size="2"><img src="/img/revistas/rfiua/n43/n43a09i02.gif"><a name="tabla2"></a> <img src="/img/revistas/rfiua/n43/n43a09i03.gif"><a name="tabla2"></a></font></p>     <p><font face="Verdana" size="2"><b>Sistema piloto de distribuci&oacute;n</b></font>  </p>     <p><font face="Verdana" size="2">Un sistema piloto de distribuci&oacute;n se considera importante para la ejecuci&oacute;n de un estudio orientado a la interacci&oacute;n del agua potable con la tuber&iacute;a en sistemas de distribuci&oacute;n, ya que posibilita evaluar el deterioro del material de tuber&iacute;a, la variaci&oacute;n en la calidad del agua y la generaci&oacute;n de dep&oacute;sitos y biopel&iacute;cula en la tuber&iacute;a. Lo anterior se logra debido a las bondades que ofrecen estos dispositivos, ya que permiten determinar la velocidad de corrosi&oacute;n de los materiales met&aacute;licos de tuber&iacute;a, realizar muestreos del agua y analizar los productos formados en la tuber&iacute;a. Las caracter&iacute;sticas del sistema se presentan en la <a href="#tabla3">tabla 3</a>, donde se resumen y sustentan las variables consideradas en el dise&ntilde;o del sistema, siguiendo las recomendaciones y los valores reportados en la literatura. A continuaci&oacute;n se presentan las principales caracter&iacute;sticas de un sistema piloto seleccionado para estudiar los efectos de la interacci&oacute;n del agua y materiales de tuber&iacute;a en el deterioro de las tuber&iacute;as y en la calidad del agua potable en la ciudad de Medell&iacute;n.  </font></p>     <p><font face="Verdana" size="2">Para cada material met&aacute;lico propuesto a evaluar en el proyecto se dispondr&aacute; de un sistema piloto. La configuraci&oacute;n de estos sistemas es similar, la &uacute;nica variaci&oacute;n es el material de ensayo expuesto en estos. La presi&oacute;n del piloto es de 276 KPa similar a lo reportado en otros estudios [21], la cual se encuentra dentro del rango establecido de operaci&oacute;n en sistemas de distribuci&oacute;n, se reporta que la presi&oacute;n m&iacute;nima debe ser de 98,1 a 147,2 KPa seg&uacute;n el nivel de complejidad del sistema de distribuci&oacute;n, sin sobrepasar los 588,6 KPa [35].  </font></p>     <p><font face="Verdana" size="2"><b>Descripci&oacute;n del Sistema Piloto</b> </font> </p>     <p><font face="Verdana" size="2">El sistema est&aacute; compuesto del tramo de la tuber&iacute;a de ensayo con una longitud total de 3 m, incluyendo siete tramos de 0,05 m acoplados mediante uniones universales. En ambos extremos del material de tuber&iacute;a se acopla un arreglo en tuber&iacute;a de PVC, el cual presenta una apariencia de tres eses continuas para ubicar cupones de corrosi&oacute;n que presentan un tama&ntilde;o de 0,013 por 0,076 por 0,0016 m [36]. Finalmente el circuito se cierra con un arreglo de tuber&iacute;a en PVC, el cual permite la entrada y salida del agua continuamente o la recirculaci&oacute;n del fluido con una bomba mediante un arreglo de v&aacute;lvulas. Un esquema del sistema piloto que se utilizar&aacute; en el desarrollo de las pruebas se ilustra en la <a href="#figura1">figura 1</a>.  </font></p>     <p><font face="Verdana" size="2">Las caracter&iacute;sticas que presenta el sistema piloto son asignadas para tener en contacto la tuber&iacute;a con el agua potable en todo momento, realizar muestreos del agua, exponer tramos de tuber&iacute;a para inspeccionar la superficie y ubicar cupones del material para determinar la velocidad de corrosi&oacute;n. Como se observa, el sistema piloto presenta la posibilidad de trabajar con flujo a trav&eacute;s o con recirculaci&oacute;n del fluido, la cual se logra mediante    un conjunto de v&aacute;lvulas que permiten realizar las adecuaciones. El sistema se ubica en un sistema de distribuci&oacute;n, por tanto un solo paso del fluido es la operaci&oacute;n normal en la cual se tiene en contacto la superficie interna de la tuber&iacute;a con el agua.   Por otro lado, la recirculaci&oacute;n permite brindar un tiempo adecuado de contacto entre la tuber&iacute;a y el agua, proceso en el cual se realiza el muestreo del agua antes y despu&eacute;s de la operaci&oacute;n para evaluar las variaciones en los par&aacute;metros del agua. Los tramos de tuber&iacute;a se retiran a lo largo de la exposici&oacute;n para analizar el ataque al material y la formaci&oacute;n de dep&oacute;sitos y biopel&iacute;cula. Adicionalmente, para determinar la velocidad de corrosi&oacute;n del material de tuber&iacute;a en el estudio, se ubican cupones de corrosi&oacute;n por triplicado para cada tiempo de an&aacute;lisis, en las dos l&iacute;neas de tuber&iacute;a de PVC que presentan forma de eses.  </font></p>     <p><font face="Verdana" size="2"><b>Tabla 3</b> Especificaciones del sistema piloto elegido</font>  </p>     <p align="center"><font face="Verdana" size="2"><img src="/img/revistas/rfiua/n43/n43a09i04.gif"><a name="tabla3"></a></font></p>     ]]></body>
<body><![CDATA[<p align="center"><font face="Verdana" size="2"><img src="/img/revistas/rfiua/n43/n43a09i05.gif"><a name="figura1"></a></font></p>     <p><font face="Verdana" size="2"><b>Figura 1</b> Esquema del sistema piloto</font>  </p>     <p><font face="Verdana" size="2">La variaci&oacute;n de la calidad del agua y el deterioro de la tuber&iacute;a de ensayo se realizar&aacute; evaluando los par&aacute;metros fisicoqu&iacute;micos y microbiol&oacute;gicos del agua, que de acuerdo a lo reportado en la literatura pueden presentar cambios apreciables a lo largo de un sistema de distribuci&oacute;n y que est&aacute;n asociados con el deterioro del material de tuber&iacute;a. Los par&aacute;metros elegidos que podr&aacute;n informar sobre el deterioro de la calidad del agua se listan en la <a href="#tabla4">tabla 4</a>, especificando los sistemas pilotos en los cuales se evaluar&aacute;n.</font></p>     <p> <font face="Verdana" size="2">El muestreo del agua se realizar&aacute; con una frecuencia semanal durante los primeros tres meses del estudio en el sistema piloto (tiempo en el cual se espera la formaci&oacute;n de una capa de &oacute;xidos y dep&oacute;sitos en la superficie, ligeramente estable) y posteriormente su frecuencia ser&aacute; quincenal, para un buen uso de los recursos. Las muestras se tomar&aacute;n en el piloto al inicio y al final de la operaci&oacute;n del sistema en condiciones de recirculaci&oacute;n, en las cuales se determinar&aacute;n los par&aacute;metros definidos. Est&aacute;s muestras se realizar&aacute;n por el tiempo propuesto para el estudio en el piloto, el cual es 1 a&ntilde;o.  </font></p>     <p><font face="Verdana" size="2"><b>Tabla 4</b> Par&aacute;metros a evaluar para determinaci&oacute;n de la calidad del agua en el estudio  </font></p>     <p align="center"><font face="Verdana" size="2"><img src="/img/revistas/rfiua/n43/n43a09i06.gif"><a name="tabla4"></a></font></p>     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Conclusi&oacute;n</b></font></font>  </p>     <p><font face="Verdana" size="2">La revisi&oacute;n de literatura especializada posibilit&oacute; establecer las caracter&iacute;sticas de dise&ntilde;o de los sistemas pilotos de distribuci&oacute;n y simult&aacute;neamente permiti&oacute; definir los valores de las variables f&iacute;sicas e hidr&aacute;ulicas empleadas para el montaje de estos sistemas, as&iacute; como la frecuencia de muestreo del agua y de la biopel&iacute;cula, lo cual se aplic&oacute; para dise&ntilde;ar un sistema piloto. La implementaci&oacute;n de &eacute;ste permitir&aacute; estudiar la interacci&oacute;n entre el agua   potable y la tuber&iacute;a con el objeto de evaluar la formaci&oacute;n de dep&oacute;sitos y biopel&iacute;cula en las superficies internas de tuber&iacute;as, el deterioro de la calidad del agua y la degradaci&oacute;n de los materiales de tuber&iacute;a. Lo anterior permitir&aacute; establecer el posible mecanismo de corrosi&oacute;n de cada material met&aacute;lico de tuber&iacute;a, as&iacute; como determinar el deterioro de la calidad del agua, en funci&oacute;n del tipo de material y el tiempo de operaci&oacute;n del sistema, con el prop&oacute;sito de plantear soluciones a los problemas que se presentan en los sistemas de distribuci&oacute;n y adicionalmente, brindando bienestar al usuario final.  </font></p>     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Agradecimientos</b></font></font></p>     <p> <font face="Verdana" size="2">Los autores quieren expresar sus agradecimientos a COLCIENCIAS por el apoyo brindado a trav&eacute;s del Programa Grupo Red de Cooperaci&oacute;n en Investigaci&oacute;n sobre el Agua - GRECIA. Adem&aacute;s, John Fredy Rios R. desea agradecer a la misma entidad la beca doctoral. </font> </p>     ]]></body>
<body><![CDATA[<p></p>     <p><font face="Verdana" size="2"><font face="Verdana" size="3"><b>Referencias</b></font></font>  </p>     <!-- ref --><p><font face="Verdana" size="2">1. M. J. Lehtola, I. T. Miettinen, M. M. Kein&auml;nen, T. K. Kekki, O. Laine, A. Hirvonen, T. Vartiainen. P. J. Martikainen. 'Microbiology, chemistry and biofilm development in a pilot drinking water distribution system with copper and plastic pipes'. <i>Water research</i>. Vol. 38. 2004. pp. 3769-3779.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000065&pid=S0120-6230200800010000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2"> 2. N. Boulay, M. Edwards. 'Role of temperature, chlorine, and organic matter in copper corrosion byproduct release in soft water'. <i>Water research</i>. Vol. 35. 2001. pp. 683-690.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000066&pid=S0120-6230200800010000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">3. S. Takasaki, Y. Yamada. 'Effects of temperature and aggresive anions on corrosion of carbon steel in potable water'. <i>Corrosion Science</i>. Vol.49. 2007. pp. 240-247. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000067&pid=S0120-6230200800010000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">4. Z. Tang, S. Hong, W. Xiao, J. Taylor. 'Impacts of blending ground, surface, and saline waters on lead release in drinking water distribution systems'.<i> Water research</i>. Vol. 40. 2006. pp. 943-950. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000068&pid=S0120-6230200800010000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">5. M. Momba, R. Kfir, S. N. Venter, T.E. Cloete. 'An overview of biofilm formation in distribution systems and its impact on the deterioration of water quality'.<i> Water S.A.</i> Vol. 26. 2000. pp. 59-66. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000069&pid=S0120-6230200800010000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">6. D. Kooij, H. R Veenendaal, C. Baars-Lorist, D. W. Klift, Y. C. Drost. 'Biofilm formation on surfaces of glass and teflon exposed to treated water'. <i>Water research</i>. Vol. 29. 1995. pp. 1655-1662. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000070&pid=S0120-6230200800010000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">7. E. Torvinen, S. Suomalainen, M. J. Lehtola, I. T. Miettinen, O. Zacheus, L. Paulin, M. L. Katila, P. J. Martikainen. 'Mycobacteria in water and loose deposits of drinking water distribucion systems in Finland'. <i>Applied and Environmental Microbiology</i>. Vol. 70. 2004. pp. 1973-1981.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000071&pid=S0120-6230200800010000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">8. T. Schwartz, S. Hoffmann, U. Obst. 'Formation and bacterial composition of young, natural biofilms obtained from public bank-filtered drinking water systems'. <i>Water research</i>. Vol. 32. 1998. pp. 2787- 2797. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000072&pid=S0120-6230200800010000900008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">9. J. C. Nickel, I. Ruseska, J. B. Wright, J. W. Costerton. 'Tobramycin Resistance of Pseudomonas aeruginosa Cells Growing as a Biofilm on Urinary Catheter Material'.<i> Antimicrobial agents and chemotherapy</i>. Vol. 27. 1985. pp. 619-624.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000073&pid=S0120-6230200800010000900009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">10. J. W. Costerton, E. S. Lashen. 'Influence of biofilm on efficacy of biocides on corrosion-causing bacteria'.<i> Material Performance</i>. Vol. 23. 1984. pp. 13-17.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-6230200800010000900010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2"> 11. M. N. B. Momba, N. Makala. 'Comparing the effect of various pipe materials on biofilm formation in chlorinated and combined chlorine-chloraminated water systems'. <i>Water S.A.</i> Vol. 30. 2004. pp. 175- 182.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000075&pid=S0120-6230200800010000900011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">12. M. N. B. Momba, N. Makala. 'Combining chlorination and chloramination processes for the inhibition of biofilm formation in drinking surface water system models'. <i>Journal of Applied Microbiology.</i> Vol. 92. 2002. pp. 641-648.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-6230200800010000900012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">13. G. A. Gagnon, J. L. Rand, K. C. O'Leary, A. C. Rygel, C. Chauret, R. C. Andrews. 'Disinfectant efficacy of chlorite and chlorine dioxide in drinking water biofilms'.<i> Water Research</i>. Vol. 39. 2005. pp. 1809- 1817.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000077&pid=S0120-6230200800010000900013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">14. G. A. Gagnon, P. M. Huck. 'Removal of easily biodegradable organic compounds by drinking water biofilms: analysis of kinetics and mass transfer'. <i>Water Research</i>. Vol. 35. 2001. pp. 2554-2564. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-6230200800010000900014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">15. C. Volk, E. Dundore, J. Schiermann, M. Lechevallier. 'Practical evaluation of iron corrosion control in a drinking water distribution system'.<i> Water Research</i>. Vol. 34. 2000. pp. 1967-1974. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000079&pid=S0120-6230200800010000900015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">16. S. Ndiongue, P. M. Huck, R. M. Slawson. 'Effects of temperature and biodegradable organic matter on control of biofilms by free chlorine in a model drinking water distribution system.'<i> Water Research</i>. Vol. 39. 2005. pp. 953-964.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-6230200800010000900016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">17. R. Boe-Hansen. 'Microbial growth in drinking water distribution systems'. Ph.D. Thesis. Environment &amp; Resources DTU, Technical University of Denmark. 2001. <a href="http://www.er.dtu.dk/publications/fulltext/2001/ MR2001-075.pdf " target="_blank">http://www.er.dtu.dk/publications/fulltext/2001/ MR2001-075.pdf </a>Consultada el 4 de agosto de 2006.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000081&pid=S0120-6230200800010000900017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">18. J. D. Eisnor, G. A. Gagnon. 'A framework for the implementation and design of pilot-scale distribution systems'.<i> Journal of Water Supply: Research and Technology-AQUA</i>. Vol. 52. 2003. pp. 501-519.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-6230200800010000900018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">19. S. A. Imran, J. D. Dietz, G. Mutoti, J. S. Taylor, A.  A. Randall. 'Modified Larsons Ratio Incorporating Temperature, Water Age, and Electroneutrality Effects on Red Water Release'. <i>Journal of Environmental Engineering</i>. Vol. 131. 2005. pp. 1514-1520.</font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S0120-6230200800010000900019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">20. Z. Tang, S. Hong, W. Xiao, J. Taylor. 'Characteristics of iron corrosion scales established under blending of ground, surface, and saline waters and their impacts on iron release in the pipe distribution system'. <i>Corrosion Science</i>. Vol. 48. 2006. pp. 322-342. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-6230200800010000900020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">21. M. J. Lehtola, I. T. Miettinen, T. Lampola, A. Hirvonen, T. Vartiainen, P. J. Martikainen. 'Pipeline materials modify the effectiveness of disinfectants in drinking water distribution systems'.<i> Water Research</i>. Vol. 39. 2005. pp. 1962-1971.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0120-6230200800010000900021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">22. P. Sarin, V. L. Snoeyink, J. Bebee, K. K. Jim, M. A. Beckett, W. M. Kriven, J. A. Clement. 'Iron release from corroded iron pipes in drinking water distribution systems: effect of dissolved oxygen'. <i>Water Research</i>. Vol. 38. 2004. pp. 1259-1269. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-6230200800010000900022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">23. J. D. Eisnor, G. A. Gagnon. 'Impact of secondary disinfection on corrosion in a model water distribution system'.<i> Journal of Water Supply: Research and Technology-AQUA</i>. Vol. 53. 2004. pp. 441-452.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0120-6230200800010000900023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">24. L. A. Rossman. 'The effect of advanced treatment on chlorine decay in metallic pipes'.<i> Water Research</i>. Vol. 40. 2006. pp. 2493-2502.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0120-6230200800010000900024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">25. T. H. Merkel, H. J. Gro&szlig;, W. Werner, T. Dahlke, S. Reicherter, G. Beuchle, S. H. Eberle. 'Copper corrosion by-product release in long-term stagnation experiments'.<i> Water Research</i>. Vol. 36. 2002. pp. 1547-1555. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0120-6230200800010000900025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">26. V. Lund, K. Osmerod. 'The influence of disinfection processes on biofilm formation in water distribution systems'. <i>Water Research</i>. Vol. 29. 1995. pp. 1013- 1021.</font>  &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-6230200800010000900026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">27. S. L. Percival, J. S. Knapp, R. Edyvean, D. S.Wales. 'Biofilm Development on Stainless Steel in Mains Water'. <i>Water Research</i>. Vol. 32. 1998. pp. 243-253. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0120-6230200800010000900027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">28. M. W. LeChevallier, C. D. Lowry, R. G. Lee. 'Disinfecting biofilms in a model distribution system'. <i>Journal AWWA.ssoc</i>. Vol. 82. 1990. pp. 87-99.</font>  &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-6230200800010000900028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">29. S. A. Imran, J. D. Dietz, G. Mutoti, J. S. Taylor, A. A. Randall, C. D. Cooper. 'Red Water Release in Drinking Water Distribution Systems'. <i>Journal AWWA</i>. Vol. 97. 2005. pp. 93-100.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0120-6230200800010000900029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">30. M. J. Lehtola, M. Laxander, I. T. Miettinen, A. Hirvonen, T. Vartiainen, P. J. Martikainen. 'The effects of changing water flow velocity on the formation of biofilms and water quality in pilot distribution system consisting of copper or polyethylene pipes'. <i>Water Research</i>. Vol. 40. 2006. pp. 2151-2160.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0120-6230200800010000900030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p> <font face="Verdana" size="2">31. C. D. Norton, M. W. Lechevallier. 'A Pilot Study of Bacteriological Population Changes through Potable Water Treatment and Distribution'.<i> Applied and Environmental Microbiology</i>. Vol. 66. 2000. pp. 268- 276. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0120-6230200800010000900031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">32. B. Holden, M. Greetham, B. T. Croll, J. Scutt. 'The Effect of changing inter process and final disinfection reagents on corrosion and biofilm growth in distribution pipes'.<i> Water Science and Technology</i>. Vol. 32. 1995. pp. 213-220. </font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0120-6230200800010000900032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">33. P. Sarin, V. L. Snoeyink, J. Bebee, W. M. Kriven, J. A. Clement. 'Physico-chemical characteristics of corrosion scales in old iron pipes'. <i>Water Research</i>. Vol. 35. 2001. pp. 2961-2969.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0120-6230200800010000900033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">34. ANSI/AWWA C651-92. 'Standard for disinfecting water mains'. <i>AWWA</i>. 1992. pp. 8-13.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0120-6230200800010000900034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2"> 35. Ministerio de Desarrollo Econ&oacute;mico. Rep&uacute;blica de Colombia. <i>Reglamento T&eacute;cnico del sector de Agua Potable y Saneamiento B&aacute;sico RAS-2000. Secci&oacute;n II, Titulo B, Sistemas de Acueducto</i>. <a href="http://www.minambiente.gov.co/viceministerios/ambiente/dir_agua_potable_saneam_basico/direccion/TituloBOct2. pdf " target="_blank">http://www.minambiente.gov.co/viceministerios/ambiente/dir_agua_potable_saneam_basico/direccion/TituloBOct2. pdf </a>Consultada el 18 de enero de 2007.  </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0120-6230200800010000900035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana" size="2">36. Designation ASTM D2688. 'Standard Test Methods for Corrosivity of Water in the Absence of Heat Transfer (Weight Loss Methods)'. ASTM International. 2005. pp. 1-7.</font> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0120-6230200800010000900036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p></p>      <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">(Recibido el 28 de marzo de 2007. Aceptado el 9 de noviembre de 2007) </font><font face="Verdana" size="2"></font>    <br>       <br> </p>      <p><font face="Verdana" size="2">* Autor de correspondencia: tel&eacute;fono: + 57 + 4 + 219 66 16, fax: + 57 + 4 + 219 64 02, correo electr&oacute;nico: <a href="mailto:jacalder@udea.edu.co">jacalder@udea.edu.co</a> (J. Calder&oacute;n).</font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lehtola]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Miettinen]]></surname>
<given-names><![CDATA[I. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Keinänen]]></surname>
<given-names><![CDATA[M. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Kekki]]></surname>
<given-names><![CDATA[T. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Laine]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Hirvonen]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vartiainen]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Martikainen]]></surname>
<given-names><![CDATA[P. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microbiology, chemistry and biofilm development in a pilot drinking water distribution system with copper and plastic pipes]]></article-title>
<source><![CDATA[Water research]]></source>
<year>2004</year>
<volume>38</volume>
<page-range>3769-3779</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boulay]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Edwards]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Role of temperature, chlorine, and organic matter in copper corrosion byproduct release in soft water]]></article-title>
<source><![CDATA[Water research]]></source>
<year>2001</year>
<volume>35</volume>
<page-range>683-690</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Takasaki]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Yamada]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of temperature and aggresive anions on corrosion of carbon steel in potable water]]></article-title>
<source><![CDATA[Corrosion Science]]></source>
<year>2007</year>
<volume>49</volume>
<page-range>240-247</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Hong]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Xiao]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impacts of blending ground, surface, and saline waters on lead release in drinking water distribution systems]]></article-title>
<source><![CDATA[Water research]]></source>
<year>2006</year>
<volume>40</volume>
<page-range>943-950</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Momba]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Kfir]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Venter]]></surname>
<given-names><![CDATA[S. N.]]></given-names>
</name>
<name>
<surname><![CDATA[Cloete]]></surname>
<given-names><![CDATA[T.E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An overview of biofilm formation in distribution systems and its impact on the deterioration of water quality]]></article-title>
<source><![CDATA[Water S.A]]></source>
<year>2000</year>
<volume>26</volume>
<page-range>59-66</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kooij]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Veenendaal]]></surname>
<given-names><![CDATA[H. R]]></given-names>
</name>
<name>
<surname><![CDATA[Baars-Lorist]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Klift]]></surname>
<given-names><![CDATA[D. W.]]></given-names>
</name>
<name>
<surname><![CDATA[Drost]]></surname>
<given-names><![CDATA[Y. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biofilm formation on surfaces of glass and teflon exposed to treated water]]></article-title>
<source><![CDATA[Water research]]></source>
<year>1995</year>
<volume>29</volume>
<page-range>1655-1662</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torvinen]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Suomalainen]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Lehtola]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Miettinen]]></surname>
<given-names><![CDATA[I. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Zacheus]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Paulin]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Katila]]></surname>
<given-names><![CDATA[M. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Martikainen]]></surname>
<given-names><![CDATA[P. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mycobacteria in water and loose deposits of drinking water distribucion systems in Finland]]></article-title>
<source><![CDATA[Applied and Environmental Microbiology]]></source>
<year>2004</year>
<volume>70</volume>
<page-range>1973-1981</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schwartz]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffmann]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Obst]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Formation and bacterial composition of young, natural biofilms obtained from public bank-filtered drinking water systems]]></article-title>
<source><![CDATA[Water research]]></source>
<year>1998</year>
<volume>32</volume>
<page-range>2787- 2797</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nickel]]></surname>
<given-names><![CDATA[J. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ruseska]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Wright]]></surname>
<given-names><![CDATA[J. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Costerton]]></surname>
<given-names><![CDATA[J. W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tobramycin Resistance of Pseudomonas aeruginosa Cells Growing as a Biofilm on Urinary Catheter Material]]></article-title>
<source><![CDATA[Antimicrobial agents and chemotherapy]]></source>
<year>1985</year>
<volume>27</volume>
<page-range>619-624</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costerton]]></surname>
<given-names><![CDATA[J. W.]]></given-names>
</name>
<name>
<surname><![CDATA[Lashen]]></surname>
<given-names><![CDATA[E. S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of biofilm on efficacy of biocides on corrosion-causing bacteria]]></article-title>
<source><![CDATA[Material Performance]]></source>
<year>1984</year>
<volume>23</volume>
<page-range>13-17</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Momba]]></surname>
<given-names><![CDATA[M. N. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Makala]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparing the effect of various pipe materials on biofilm formation in chlorinated and combined chlorine-chloraminated water systems]]></article-title>
<source><![CDATA[Water S.A.]]></source>
<year>2004</year>
<volume>30</volume>
<page-range>175- 182</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Momba]]></surname>
<given-names><![CDATA[M. N. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Makala]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Combining chlorination and chloramination processes for the inhibition of biofilm formation in drinking surface water system models]]></article-title>
<source><![CDATA[Journal of Applied Microbiology]]></source>
<year>2002</year>
<volume>92</volume>
<page-range>641-648</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gagnon]]></surname>
<given-names><![CDATA[G. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rand]]></surname>
<given-names><![CDATA[J. L.]]></given-names>
</name>
<name>
<surname><![CDATA[O'Leary]]></surname>
<given-names><![CDATA[K. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Rygel]]></surname>
<given-names><![CDATA[A. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Chauret]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Andrews]]></surname>
<given-names><![CDATA[R. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Disinfectant efficacy of chlorite and chlorine dioxide in drinking water biofilms]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2005</year>
<volume>39</volume>
<page-range>1809- 1817</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gagnon]]></surname>
<given-names><![CDATA[G. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Huck]]></surname>
<given-names><![CDATA[P. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of easily biodegradable organic compounds by drinking water biofilms: analysis of kinetics and mass transfer]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2001</year>
<volume>35</volume>
<page-range>2554-2564</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Volk]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Dundore]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Schiermann]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Lechevallier]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Practical evaluation of iron corrosion control in a drinking water distribution system]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2000</year>
<volume>34</volume>
<page-range>1967-1974</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ndiongue]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Huck]]></surname>
<given-names><![CDATA[P. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Slawson]]></surname>
<given-names><![CDATA[R. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of temperature and biodegradable organic matter on control of biofilms by free chlorine in a model drinking water distribution system]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2005</year>
<volume>39</volume>
<page-range>953-964</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boe-Hansen]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Microbial growth in drinking water distribution systems]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eisnor]]></surname>
<given-names><![CDATA[J. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Gagnon]]></surname>
<given-names><![CDATA[G. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A framework for the implementation and design of pilot-scale distribution systems]]></article-title>
<source><![CDATA[Journal of Water Supply: Research and Technology-AQUA]]></source>
<year>2003</year>
<volume>52</volume>
<page-range>501-519</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Imran]]></surname>
<given-names><![CDATA[S. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Dietz]]></surname>
<given-names><![CDATA[J. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Mutoti]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[J. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Randall]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modified Larsons Ratio Incorporating Temperature, Water Age, and Electroneutrality Effects on Red Water Release]]></article-title>
<source><![CDATA[Journal of Environmental Engineering]]></source>
<year>2005</year>
<volume>131</volume>
<page-range>1514-1520</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Hong]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Xiao]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[J.]]></surname>
<given-names><![CDATA[Taylor]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characteristics of iron corrosion scales established under blending of ground, surface, and saline waters and their impacts on iron release in the pipe distribution system]]></article-title>
<source><![CDATA[Corrosion Science]]></source>
<year>2006</year>
<volume>48</volume>
<page-range>322-342</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lehtola]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Miettinen]]></surname>
<given-names><![CDATA[I. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lampola]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hirvonen]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vartiainen]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Martikainen]]></surname>
<given-names><![CDATA[P. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pipeline materials modify the effectiveness of disinfectants in drinking water distribution systems]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2005</year>
<volume>39</volume>
<page-range>1962-1971</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarin]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Snoeyink]]></surname>
<given-names><![CDATA[V. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Bebee]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Jim]]></surname>
<given-names><![CDATA[K. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Beckett]]></surname>
<given-names><![CDATA[M. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Kriven]]></surname>
<given-names><![CDATA[W. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Clement]]></surname>
<given-names><![CDATA[J. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Iron release from corroded iron pipes in drinking water distribution systems: effect of dissolved oxygen]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2004</year>
<volume>38</volume>
<page-range>1259-1269</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eisnor]]></surname>
<given-names><![CDATA[J. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Gagnon]]></surname>
<given-names><![CDATA[G. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impact of secondary disinfection on corrosion in a model water distribution system]]></article-title>
<source><![CDATA[Journal of Water Supply: Research and Technology-AQUA]]></source>
<year>2004</year>
<volume>53</volume>
<page-range>441-452</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rossman]]></surname>
<given-names><![CDATA[L. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of advanced treatment on chlorine decay in metallic pipes]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2006</year>
<volume>40</volume>
<page-range>2493-2502</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Merkel]]></surname>
<given-names><![CDATA[T. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Groß]]></surname>
<given-names><![CDATA[H. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Werner]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Dahlke]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Reicherter]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Beuchle]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Eberle]]></surname>
<given-names><![CDATA[S. H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Copper corrosion by-product release in long-term stagnation experiments]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2002</year>
<volume>36</volume>
<page-range>1547-1555</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lund]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Osmerod]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of disinfection processes on biofilm formation in water distribution systems]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>1995</year>
<volume>29</volume>
<page-range>1013- 1021</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Percival]]></surname>
<given-names><![CDATA[S. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Knapp]]></surname>
<given-names><![CDATA[J. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Edyvean]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Wales]]></surname>
<given-names><![CDATA[D. S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biofilm Development on Stainless Steel in Mains Water]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>1998</year>
<volume>32</volume>
<page-range>243-253</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[LeChevallier]]></surname>
<given-names><![CDATA[M. W.]]></given-names>
</name>
<name>
<surname><![CDATA[Lowry]]></surname>
<given-names><![CDATA[C. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[R. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Disinfecting biofilms in a model distribution system]]></article-title>
<source><![CDATA[Journal AWWA.ssoc.]]></source>
<year>1990</year>
<volume>82</volume>
<page-range>87-99</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Imran]]></surname>
<given-names><![CDATA[S. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Dietz]]></surname>
<given-names><![CDATA[J. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Mutoti]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[J. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Randall]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[C. D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Red Water Release in Drinking Water Distribution Systems]]></article-title>
<source><![CDATA[Journal AWWA]]></source>
<year>2005</year>
<volume>97</volume>
<page-range>93-100</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lehtola]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Laxander]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Miettinen]]></surname>
<given-names><![CDATA[I. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hirvonen]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vartiainen]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Martikainen]]></surname>
<given-names><![CDATA[P. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effects of changing water flow velocity on the formation of biofilms and water quality in pilot distribution system consisting of copper or polyethylene pipes]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2006</year>
<volume>40</volume>
<page-range>2151-2160</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[C. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Lechevallier]]></surname>
<given-names><![CDATA[M. W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Pilot Study of Bacteriological Population Changes through Potable Water Treatment and Distribution]]></article-title>
<source><![CDATA[Applied and Environmental Microbiology]]></source>
<year>2000</year>
<volume>66</volume>
<page-range>268- 276</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holden]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Greetham]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Croll]]></surname>
<given-names><![CDATA[B. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Scutt]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Effect of changing inter process and final disinfection reagents on corrosion and biofilm growth in distribution pipes]]></article-title>
<source><![CDATA[Water Science and Technology]]></source>
<year>1995</year>
<volume>32</volume>
<page-range>213-220</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarin]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Snoeyink]]></surname>
<given-names><![CDATA[V. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Bebee]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Kriven]]></surname>
<given-names><![CDATA[W. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Clement]]></surname>
<given-names><![CDATA[J. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Physico-chemical characteristics of corrosion scales in old iron pipes]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2001</year>
<volume>35</volume>
<page-range>2961-2969</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="book">
<collab>ANSI/AWWA C651-92</collab>
<source><![CDATA[Standard for disinfecting water mains]]></source>
<year>1992</year>
<page-range>8-13</page-range><publisher-name><![CDATA[AWWA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="">
<collab>República de Colombia^dMinisterio de Desarrollo Económico</collab>
<source><![CDATA[Reglamento Técnico del sector de Agua Potable y Saneamiento Básico RAS-2000: Sección II, Titulo B, Sistemas de Acueducto]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="book">
<collab>Designation ASTM D2688</collab>
<source><![CDATA[Standard Test Methods for Corrosivity of Water in the Absence of Heat Transfer (Weight Loss Methods)]]></source>
<year>2005</year>
<page-range>1-7</page-range><publisher-name><![CDATA[ASTM International]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>