<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-6230</journal-id>
<journal-title><![CDATA[Revista Facultad de Ingeniería Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev.fac.ing.univ. Antioquia]]></abbrev-journal-title>
<issn>0120-6230</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería, Universidad de Antioquia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-62302013000200015</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Remoción de fósforo de diferentes aguas residuales en reactores aeróbios de lecho fluidizado trifásico con circulación interna]]></article-title>
<article-title xml:lang="en"><![CDATA[Phosphorus removal in different wastewater by fluidized bed airlift reactors with internal circulation]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Teixeira Correia]]></surname>
<given-names><![CDATA[Gleyce]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sánchez Ortiz]]></surname>
<given-names><![CDATA[Iván Andrés]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gebara]]></surname>
<given-names><![CDATA[Dib]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Dall'Aglio Sobrinho]]></surname>
<given-names><![CDATA[Milton]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Matsumoto]]></surname>
<given-names><![CDATA[Tsunao]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,UNESP Faculdade de Engenharia de Ilha Solteira Departamento de Engenharia Civil]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Brasil</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Nariño Departamento de Recursos Hidrobiológicos ]]></institution>
<addr-line><![CDATA[Pasto ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2013</year>
</pub-date>
<numero>67</numero>
<fpage>172</fpage>
<lpage>182</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-62302013000200015&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-62302013000200015&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-62302013000200015&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El vertimiento de aguas residuales (AR) produce impactos sobre los cuerpos de agua receptores. Nutrientes como P generan implicaciones en los sistemas lénticos pues aceleran los procesos de eutrofización. Se han utilizado diversas tecnologías para la remoción de P de las AR: sistemas de tratamiento físico químico con importantes efectos por adición de productos coagulantes; procesos biológicos basados en alternancia de condiciones anaerobias y aerobias con importantes implicaciones de volumen necesario; sistemas como lagunas de estabilización e irrigación requieren de áreas muy considerables y procesos de postratamiento. Los reactores aerobios de lecho fluidizado con circulación interna (RALFCI) son opciones compactas que utilizan gran concentración de biomasa activa que han demostrado su capacidad para remover materia orgánica y N. Para AR domésticas provenientes de la estación de bombeo de Ilha Solteira y para los efluentes de un sistema de recirculación acuícola (SRA) de cultivo semi-intensivo de tilapia se evaluó la eficiencia de remoción de P reactivo y P total en tres tipos de RALFCI con diámetro externo de 250 mm y diferentes diámetros de tubo interno (DTI), con dos medios de soporte y diferentes concentraciones en dos de los reactores. Las eficiencias medias de remoción de P reactivo en AR domésticas para un tiempo de retención hidráulica (TRH) de 3 horas en el reactor con DTI 125 mm variaron entre 25,6 y 38,4% y en el reactor con DTI 150 mm entre 27,5 y 32,5%; la remoción de P total en el SRA para un TRH de 0,19 h y DTI 100 mm fue de 32,7%.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Remoción biológica de fósforo]]></kwd>
<kwd lng="es"><![CDATA[reactor aerobio]]></kwd>
<kwd lng="es"><![CDATA[lecho fluidizado]]></kwd>
<kwd lng="es"><![CDATA[circulación]]></kwd>
<kwd lng="en"><![CDATA[Biological phosphorus removal]]></kwd>
<kwd lng="en"><![CDATA[aerobic reactor]]></kwd>
<kwd lng="en"><![CDATA[fluidized bed]]></kwd>
<kwd lng="en"><![CDATA[internal circulation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><b>ART&Iacute;CULO ORIGINAL</b></p>     <p align="right">&nbsp;</p>     <p align="center"><font size="4"> <b>Remoci&oacute;n de f&oacute;sforo de diferentes aguas residuales en reactores aer&oacute;bios de lecho fluidizado trif&aacute;sico con circulaci&oacute;n interna</b></font></p>     <p align="center">&nbsp;</p>     <p align="center"><font size="3"> <b>Phosphorus removal in different wastewater by fluidized bed airlift reactors with internal circulation</b></font></p>     <p align="center">&nbsp;</p>     <p align="center">&nbsp;</p>     <p> <i><b>Gleyce Teixeira Correia<sup>1</sup>, Iv&aacute;n Andr&eacute;s S&aacute;nchez Ortiz<sup>2*</sup>, Dib Gebara<sup>1</sup>, Milton Dall'Aglio Sobrinho<sup>1</sup>, Tsunao Matsumoto<sup>1</sup></b></i></p>       <p><sup>1</sup>UNESP, Faculdade de Engenharia de  Ilha Solteira - Departamento de Engenharia Civil. Alameda Bahia, 550 - Ilha  Solteira - SP - CEP: 15385-000, Brasil.</p>      <p><sup>2</sup>Departamento de Recursos  Hidrobiol&oacute;gicos. Universidad de Nari&ntilde;o, Cll 18 Cra 50. Ciudad Universitaria,  Torobajo. Pasto, Colombia.</p>      ]]></body>
<body><![CDATA[<p><sup>*</sup>Autor de correspondencia:  tel&eacute;fono: + 57 + 2 + 731 14 49 ext. 239, fax + 57 + 2 + 731 44 82, correo  electr&oacute;nico: <a href="mailto:iaso@udenar.edu.co">iaso@udenar.edu.co</a> (I. S&aacute;nchez)</p>      <p>&nbsp;</p>     <p align="center">(Recibido el 24 de  Septiembre de 2012. Aceptado el 26 de abril de 2013)</p>     <p align="center">&nbsp;</p>     <p align="center">&nbsp;</p> <hr noshade size="1">      <p><font size="3"><b>Resumen</b></font></p>      <p>El vertimiento de aguas residuales  (AR) produce impactos sobre los cuerpos de agua receptores. Nutrientes como P  generan implicaciones en los sistemas l&eacute;nticos pues aceleran los procesos de  eutrofizaci&oacute;n. Se han utilizado diversas tecnolog&iacute;as para la remoci&oacute;n de P de  las AR: sistemas de tratamiento f&iacute;sico qu&iacute;mico con importantes efectos por  adici&oacute;n de productos coagulantes; procesos biol&oacute;gicos basados en alternancia de  condiciones anaerobias y aerobias con importantes implicaciones de volumen  necesario; sistemas como lagunas de estabilizaci&oacute;n e irrigaci&oacute;n requieren de  &aacute;reas muy considerables y procesos de postratamiento. Los reactores aerobios de  lecho fluidizado con circulaci&oacute;n interna (RALFCI) son opciones compactas que  utilizan gran concentraci&oacute;n de biomasa activa que han demostrado su capacidad  para remover materia org&aacute;nica y N. Para AR dom&eacute;sticas provenientes de la  estaci&oacute;n de bombeo de Ilha Solteira y para los efluentes de un sistema de  recirculaci&oacute;n acu&iacute;cola (SRA) de cultivo semi-intensivo de tilapia se evalu&oacute; la  eficiencia de remoci&oacute;n de P reactivo y P total en tres tipos de RALFCI con  di&aacute;metro externo de 250 mm y diferentes di&aacute;metros de tubo interno (DTI), con  dos medios de soporte y diferentes concentraciones en dos de los reactores. Las  eficiencias medias de remoci&oacute;n de P reactivo en AR dom&eacute;sticas para un tiempo de  retenci&oacute;n hidr&aacute;ulica (TRH) de 3 horas en el reactor con DTI 125 mm variaron  entre 25,6 y 38,4% y en el reactor con DTI 150 mm entre 27,5 y 32,5%; la  remoci&oacute;n de P total en el SRA para un TRH de 0,19 h y DTI 100 mm fue de 32,7%.</p>       <p><i>Palabras clave: </i>Remoci&oacute;n biol&oacute;gica de f&oacute;sforo, reactor aerobio, lecho fluidizado, circulaci&oacute;n </p>  <hr noshade size="1">      <p><font size="3"><b>Abstract</b></font></p>     <p>The wastewater discharge  produces impacts on receiving water bodies. Nutrients as P produce implications  on lentic systems because they accelerate the eutrophication processes. Several  technologies for P removal from the wastewater have been used: physic chemical  treatment systems with important effects by coagulant products addition;  biological processes based on anaerobic and aerobic conditions with great  implications on the required volume; natural systems as stabilization ponds and  irrigation require bigger areas and post-treatment processes. The aerobic  fluidized bed reactors with internal circulation (AFBRIC) are compact options  with high concentrations of active biomass that have demonstrated their  capacity for organic matter and N removal. For sewage from the wastewater  pumping station of Ilha Solteira city and effluents of a recirculation  aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and  total P removal efficiency in three AFBRIC with 250 mm external tube diameter  and different internal tube diameter (ITD), for two different support media at  different concentrations was evaluated. The average reactive P removal  efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours  and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor  varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater  at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.</p>      ]]></body>
<body><![CDATA[<p><i>Keywords: </i>Biological phosphorus removal, aerobic reactor, fluidized bed, internal circulation</p>  <hr noshade size="1">      <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3"><b>Introducci&oacute;n</b></font></p>      <p>El vertimiento  de efluentes dom&eacute;sticos, pecuarios e industriales, crudos o con tratamiento  insuficiente; las aguas pluviales urbanas; las aguas de escorrent&iacute;a superficial  directa de zonas agr&iacute;colas con excesivo uso de agrot&oacute;xicos o de fertilizantes  qu&iacute;micos; la lixiviaci&oacute;n no controlada de l&iacute;quidos provenientes de cementerios,  rellenos sanitarios o dep&oacute;sitos de residuos s&oacute;lidos a cielo abierto son algunas  de las causas que generan la cada vez mayor contaminaci&oacute;n de las fuentes de  agua superficial y subterr&aacute;nea.</p>       <p>Los elementos  contaminantes presentes en las Aguas Residuales (AR) pueden ser de tipo f&iacute;sico,  qu&iacute;micoo biol&oacute;gico y algunos de los constituyentes de mayor importancia en el  tratamiento de tales aguas son: s&oacute;lidos suspendidos, elementos org&aacute;nicos biodegradables,  elementos inorg&aacute;nicos disueltos, metales pesados, nutrientes y pat&oacute;genos &#91;1&#93;.</p>       <p>Elementos en  el agua tales como carbono, nitr&oacute;geno, f&oacute;sforo, calcio, hierro, entre otros  esenciales para el crecimiento y reproducci&oacute;n de plantas y animales se denominan  nutrientes o bioestimulantes. En particular, el f&oacute;sforo que puede presentarse  en combinaci&oacute;n con la materia org&aacute;nica, en prote&iacute;nas y amino&aacute;cidos o en la  forma inorg&aacute;nica, como ortofosfato y polifosfato, es un nutriente esencial que  contribuye al crecimiento de algas y en ciertas condiciones causa la  eutrofizaci&oacute;n de lagos. En ambientes acu&aacute;ticos, el f&oacute;sforo se encuentra en la  forma de fosfato y es un nutriente limitante pues si todo el f&oacute;sforo es  utilizado, el crecimiento de las plantas se detiene, sin importar la cantidad  de nitr&oacute;geno disponible &#91;2&#93;.</p>       <p>Las aguas residuales  dom&eacute;sticas est&aacute;n compuestas en m&aacute;s del 98% por agua que contiene contaminantes  como s&oacute;lidos suspendidos, compuestos org&aacute;nicos, (40-60% prote&iacute;nas, 25-50%  carbohidratos, 10% aceites y grasas), nutrientes (nitr&oacute;geno y f&oacute;sforo),  metales, s&oacute;lidos disueltos inorg&aacute;nicos, s&oacute;lidos inertes, s&oacute;lidos gruesos,  compuestos no biodegradables, organismos pat&oacute;genos y algunas veces, presentan  tambi&eacute;n contaminantes t&oacute;xicos provenientes de actividades industriales o  accidentes &#91;3&#93;.</p>       <p>El f&oacute;sforo se encuentra  presente en las aguas residuales dom&eacute;sticas principalmente como fruto de su uso  en detergentes o como parte de las excreciones humanas. Las heces y la orina  humanas est&aacute;n compuestas entre el 3,0 y el 5,4% y entre el 2,5 y el 5,0%  respectivamente por f&oacute;sforo, en la forma de P<sub>2</sub>O<sub>5</sub> &#91;4&#93;. Las  concentraciones t&iacute;picas del nutriente en las AR dom&eacute;sticas suele oscilar entre  6 y 20mg/L en la forma de f&oacute;sforo total &#91;5&#93;.</p>       <p>Las AR de actividades  acu&iacute;colas incluyen principalmente como contaminantes el alimento no consumido y  las excretas producidas por los animales, residuos qu&iacute;micos y terap&eacute;uticos,  peces muertos o moribundos, espec&iacute;menes que escapan de la instalaci&oacute;n y  pat&oacute;genos &#91;6&#93;.</p>       ]]></body>
<body><![CDATA[<p>La producci&oacute;n acu&iacute;cola puede  ejecutarse en sistemas abiertos (con un &uacute;nico pase del agua), semicerrados (con  el reuso de una cierta fracci&oacute;n del l&iacute;quido) o cerrados (con reuso del 100% del  agua) tales como los sistemas de recirculaci&oacute;n para acuacultura (SRA). Las  concentraciones de s&oacute;lidos suspendidos totales, f&oacute;sforo total, nitr&oacute;geno total  y demanda bioqu&iacute;mica de ox&iacute;geno en efluentes de acuacultura en sistemas  abiertos suelen ser del orden del 3% o menores que las presentadas por aguas  residuales dom&eacute;sticas &#91;7&#93;.</p>       <p>En la medida en que las  densidades de siembra se incrementan se hace necesaria la aplicaci&oacute;n de buenas  pr&aacute;cticas de manejo en los sistemas abiertos &#91;8&#93; adem&aacute;s de la implementaci&oacute;n de  sistemas de tratamiento de los efluentes &#91;9&#93;.</p>       <p>En los sistemas acu&iacute;colas el  f&oacute;sforo proviene fundamentalmente de las heces, orina, restos de alimento y son  descargados en forma particulada (fase s&oacute;lida) o en forma disuelta &#91;10&#93;.</p>       <p>La cantidad de contaminaci&oacute;n  generada diariamente -en t&eacute;rminos de DQO- por una estaci&oacute;n pisc&iacute;cola que  produzca 180 toneladas de peces es comparable a la contaminaci&oacute;n producida por  una poblaci&oacute;n con 10.000 habitantes &#91;11&#93;. Una de las razones por las que se  justifica la intensificaci&oacute;n de los proyectos productivos acu&iacute;colas son las  reglamentaciones ambientales que proh&iacute;ben o limitan el vertimiento de efluentes  y la escasez o altos costos del agua.</p>       <p>Los SRA son una opci&oacute;n para la  producci&oacute;n intensiva de peces donde se garantiza tanto la seguridad como la  calidad de las especies producidas a lo largo del a&ntilde;o ya que en ellos existe un  total control del ambiente de cultivo, son sistemas ambientalmente sostenibles  pues usan entre 90 y 99% menos agua que los sistemas acu&iacute;colas convencionales.  Por el re&uacute;so constante del agua, los lodos producidos en SRA's suelen presentar  concentraciones de N y P superiores a las reportadas en s&oacute;lidos dom&eacute;sticos, con  un valor promedio de 1,3% de f&oacute;sforo total de la masa s&oacute;lida seca en lodos de  SRA &#91;12&#93;.</p>       <p>Como alternativas a la  eliminaci&oacute;n del f&oacute;sforo junto con el nitr&oacute;geno en aguas residuales se  encuentran las lagunas de estabilizaci&oacute;n, los sistemas de disposici&oacute;n  controlada en el suelo; los lodos activados y reactores aerobios con  biopel&iacute;cula y la remoci&oacute;n por procesos f&iacute;sico- qu&iacute;micos o la combinaci&oacute;n de  algunos de los anteriores &#91;13&#93;.</p>       <p>Los estudios sobre la remoci&oacute;n  biol&oacute;gica de f&oacute;sforo en plantas de tratamiento de aguas residuales por sistemas  de lodos activados iniciaron desde la d&eacute;cada de 1940; sin embargo, las  investigaciones desarrolladas en la d&eacute;cada de 1960 por Levin y Shapiro &#91;14&#93;  dinamizaron el entendimiento de la asimilaci&oacute;n metab&oacute;lica de este nutriente por  los microorganismos mediante un proceso que denominaron ''luxury  uptake''. En el contexto mundial es com&uacute;n el uso de sistemas de tratamiento  secundario conocidos como ''enhanced biological phosphorus removal (EBPR)''  &#91;15&#93;, en los que las AR pasan por etapas con diferentes condiciones de ox&iacute;geno  disuelto que propician altas remociones de f&oacute;sforo por parte de los  microorganismos involucrados en el proceso.</p>       <p>En el entorno latinoamericano  se han reportado experiencias de tratamiento como por ejemplo mediante  adaptaciones al sistema de lodos activado s donde tanque s indi viduale s  trabaj an baj o condiciones de un reactor discontinuo secuencial convencional  -llenado, mezcla anaer&oacute;bica, aireaci&oacute;n, mezcla an&oacute;xica, sedimentaci&oacute;n, vaciado-  &#91;16-19&#93;; mediante un reactor h&iacute;brido &#91;20, 21&#93;; por medio de sistemas  conformados por dos reactores, el primero en condiciones anaerobias y el  siguiente en condiciones aerobias/an&oacute;xicas &#91;22&#93; o por reactores independientes  para cada una de las fases de tratamiento &#91;23, 24&#93;.</p>       <p>En los sistemas anteriormente  mencionados se pretende que durante los cambios de las condiciones de ox&iacute;geno  disuelto los microorganismos acumulen el f&oacute;sforo m&aacute;s all&aacute; de sus necesidades  metab&oacute;licas de crecimiento para que dicho nutriente sea finalmente retirado  mediante la remoci&oacute;n de la biomasa rica en f&oacute;sforo. Bajo condiciones  operacionales espec&iacute;ficas, es posible desarrollar un lodo con un contenido de  f&oacute;sforo mucho m&aacute;s elevado que el 2,5% normalmente encontrado en lodos de  sistemas convencionales &#91;25&#93;.</p>       <p>Los reactores con biomasa  adherida han presentado gran potencial en la remoci&oacute;n de nutrientes como  nitr&oacute;geno y f&oacute;sforo &#91;26&#93;, de ah&iacute; la importancia del desarrollo de  investigaciones orientadas a evaluar la eficiencia de remoci&oacute;n de nutrientes en  ese tipo de reactores sometidos a diferentes condiciones operacionales.</p>       ]]></body>
<body><![CDATA[<p>En la presente investigaci&oacute;n  se reporta las eficiencias de remoci&oacute;n de f&oacute;sforo por parte de reactores de  lecho fluidizado trif&aacute;sico con circulaci&oacute;n interna en tubos conc&eacute;ntricos en  aguas residuales dom&eacute;sticas y provenientes de un SRA, con dos diferentes medios  soporte, evaluados para dos tiempos de retenci&oacute;n hidr&aacute;ulica y diferentes  concentraciones de medio soporte.</p>        <p>&nbsp;</p>     <p><font size="3"><b>Experimentaci&oacute;n</b></font></p>      <p><b><i>Reactores utilizados</i></b></p>      <p>Se utilizaron tres reactores de  lecho fluidizado con circulaci&oacute;n, construidos en tubos de PVC conc&eacute;ntricos con  altura nominal de 2,6 m y di&aacute;metro externo de 250 mm. La diferencia  constructiva entre los reactores se bas&oacute; en el di&aacute;metro del tubo interno, con  valores de 125 mm para el R1, 150 mm para el R2 y 100 mm para el R3, tales  configuraciones geom&eacute;tricas definen relaciones entre el &aacute;rea del tubo externo y  las del tubo interno (Ae/Ai) de 4,00; 2,78 y 6,25 para los reactores R1, R2 y  R3, respectivamente. Las caracter&iacute;sticas hidrodin&aacute;micas del funcionamiento de  los reactores en cuanto a sus velocidades de circulaci&oacute;n, fracci&oacute;n volum&eacute;trica  de aire y transferencia de ox&iacute;geno se basan en una experiencia previamente  reportada por este medio de divulgaci&oacute;n cient&iacute;fica &#91;27&#93;.</p>      <p><b><i>Sistemas de tratamiento evaluados y tipos de aguas residuales</i></b></p>      <p><i>Para las  aguas residuales dom&eacute;sticas</i>. El agua  residual urbana sometida al tratamiento por parte de los reactores R1 y R2 fue  tomada desde el pozo de succi&oacute;n de la estaci&oacute;n de bombeo de la ciudad de Ilha  Solteira - Sao Paulo. El agua residual era sometida a un tamizado est&aacute;tico con  aberturas de 1 mm, a trav&eacute;s del cual efectuaba la remoci&oacute;n de los s&oacute;lidos m&aacute;s  gruesos que ser&iacute;an indeseables al interior del reactor. En seguida, el agua  residual pasaba hacia una caja de nivel constante, desde la que por medio de  una bomba perist&aacute;ltica, se transportaba el caudal requerido hacia la parte  superior del reactor para entrar por gravedad hacia la parte inferior interna  del mismo. El esquema de flujo puede ser observado en la <a href="#Figura1">figura 1</a>.</p>      <p align="center"><a name="Figura1"></a><img src="img/revistas/rfiua/n67/n67a15i01.gif"></p>     <p align="center">&nbsp;</p>     <p><i>Para el agua residual del sistema  de recirculaci&oacute;n acu&iacute;cola (SRA)</i>.  El reactor R3 form&oacute; parte de la secuencia de tratamiento f&iacute;sico y biol&oacute;gico de  un sistema de recirculaci&oacute;n para el cultivo semi&shy;intensivo de tilapia nil&oacute;tica  cuya densidad de biomasa fue aproximadamente de 30 kg/m<sup>3</sup>. El SRA fue  instalado en el Laboratorio de Hidrolog&iacute;a e Hidrometr&iacute;a de la Facultad de  Ingenier&iacute;a de la Universidad Estadual Paulista campus de Ilha Solteira  (FEIS-UNESP).</p>       ]]></body>
<body><![CDATA[<p>El SRA para piscicultura estuvo  compuesto por una caja de nivel constante desde la que por medio de un sistema  de tuber&iacute;as de PVC se distribuy&oacute; el agua hacia tres tanques de cultivo, cada  uno con capacidad de 250 L; un decantador convencional de flujo horizontal; el  reactor aerobio de lecho fluidizado con circulaci&oacute;n y di&aacute;metro interno de 100  mm; un reactor para transferencia de ox&iacute;geno y remoci&oacute;n de CO<sub>2</sub>; un  tanque de succi&oacute;n y un sistema de bombeo del efluente final, como se puede  apreciar en la <a href="#Figura2">figura 2</a>.</p>      <p align="center"><a name="Figura2"></a><img src="img/revistas/rfiua/n67/n67a15i02.gif"></p>     <p align="center">&nbsp;</p>     <p><b><i>Medios soporte</i></b></p>      <p>Los medios soporte utilizados para  el desarrollo de la biopel&iacute;cula fueron: granos de arena para los reactores R1 y  R2 y carb&oacute;n activado granular (CAG) para el reactor R3. La caracterizaci&oacute;n de  los materiales en cuanto a su granulometr&iacute;a y masa espec&iacute;fica se realiz&oacute; seg&uacute;n  las metodolog&iacute;as descritas por la Asociaci&oacute;n Brasilera de Normas T&eacute;cnicas &#91;28,  29&#93;.</p>      <p><b><i>Operaci&oacute;n y partida de los reactores</i></b></p>      <p>Los reactores R1 y R2 se operaron  en diferentes fases, establecidas en funci&oacute;n de la cantidad de medio soporte  (arena) utilizada, dichas fases fueron: Para R1 se utilizaron 100, 125 y 150  g/L en las fases 1, 2 y 3 respectivamente; para R2 se utilizaron 100 y 125 g/L  en las fases 1 y 2 respectivamente. Desde el arranque de los reactores se garantiz&oacute;  una concentraci&oacute;n de 100 g/L de arena, el per&iacute;odo de partida fue de 15 d&iacute;as,  tiempo en el cual ocurri&oacute; el desarrollo de la biopel&iacute;cula. Despu&eacute;s de dos meses  de funcionamiento en la fase 1 se adicion&oacute; m&aacute;s arena al reactor, hasta alcanzar  los 125 g/L, iniciando as&iacute; la fase 2 en los reactores R1 y R2; despu&eacute;s de un  periodo de tiempo similar se realiz&oacute; el mismo procedimiento para comenzar la  fase 3 en el R1.</p>       <p>Para iniciar la fase 1 se  inyectaron cantidades de aire del orden de 2700 y 2900 L/h durante los primeros  15 d&iacute;as para mantener en suspensi&oacute;n el medio soporte en los reactores R1 y R2,  con el desarrollo de la biopel&iacute;cula la masa espec&iacute;fica de la part&iacute;cula (arena +  biopel&iacute;cula) disminuye y requiere de un menor caudal de aire; por ello en la  tercera semana se redujeron los caudales a 2300 y 2700 L/h en dichas unidades.  Para la fase 2 fue necesario aumentar el caudal de aire especialmente en el R1,  los valores medios en la fase fueron de 3200 y 2700 L/h para R1 y R2  respectivamente. En la tercera fase el caudal de aire proporcionado al R1 fue  del orden de 3300 L/h.</p>       <p>El caudal de agua residual que se  aplic&oacute; en los reactores fue de 41 L/h en el R1 y de 46 L/h en el R2, lo que  garantiz&oacute; un TRH del orden de aproximadamente 3 horas.</p>      <p> Por su parte, el reactor R3 se  oper&oacute; en una &uacute;nica fase en la que el medio soporte (CAG) se mantuvo en una  concentraci&oacute;n de 80 g/L, para lo cual se adicion&oacute; de manera progresiva  cantidades de material hasta cumplir con el valor de concentraci&oacute;n deseada. Con  el prop&oacute;sito de mantener en suspensi&oacute;n y circulaci&oacute;n el medio soporte se  inyect&oacute; un caudal de 2000 L/h, valor que se redujo hasta 1000 L/h una vez se  mantuvo estable la circulaci&oacute;n con los 80 g/L de CAG. Para efectos de favorecer  el crecimiento de la biopel&iacute;cula, en la primera semana de inoculaci&oacute;n se llen&oacute;  la mitad de su volumen con agua potable desclorada y la otra mitad con agua del  lago del barrio Ipe (Ilha Solteira); en la segunda semana se practic&oacute; un  recambio del 50% del volumen con agua del lago y se permiti&oacute; circular el agua  por todo el SRA (aun sin la siembra de los peces); cada d&iacute;a de la tercera  semana se practic&oacute; un recambio parcial del SRA mediante la adici&oacute;n de 200 L de  agua proveniente de la sustituci&oacute;n del l&iacute;quido de fondo de un tanque de cultivo  de peces ornamentales.</p>       ]]></body>
<body><![CDATA[<p>El caudal de agua residual  inyectado durante el experimento fue del orden de 577 L/h lo que se tradujo en  un TRH de 0,198 horas.</p>        <p><b><i>Puntos de muestreo y ensayos f&iacute;sico-qu&iacute;micos</i></b></p>        <p>Durante siete semanas del per&iacute;odo  de operaci&oacute;n de los reactores R1 y R2 se realizaron dos veces por semana los  an&aacute;lisis de f&oacute;sforo reactivo (P<sub>Reac</sub>) ortofosfato por el m&eacute;todo de  &aacute;cido asc&oacute;rbico, las muestras de agua fueron tomadas en el l&iacute;quido efluente a  los reactores (posterior a su tamizado por la malla de 1mm) y en el efluente de  R1 y R2.</p>      <p> En el caso del R3 se realizaron  an&aacute;lisis de f&oacute;sforo total (PT) dos veces por semana durante dos meses por el  m&eacute;todo de digesti&oacute;n con persulfato &aacute;cido, las muestras de agua fueron tomadas  en el afluente al sedimentador convencional y en el efluente del reactor R3.</p>       <p>Los m&eacute;todos utilizados para la  realizaci&oacute;n de los an&aacute;lisis se rigieron por las metodolog&iacute;as estandarizadas  &#91;30&#93;. Para medir las concentraciones de f&oacute;sforo en las muestras de los tres  reactores se utiliz&oacute; un espectrofot&oacute;metro Hach DR/2500 instalado en el  Laboratorio de Saneamiento de la FEIS-UNESP. De igual manera, en los tres  reactores se registraron diariamente <i>in situ</i> los valores de ox&iacute;geno disuelto,  pH y temperatura de los l&iacute;quidos afluentes y efluentes por medio de una sonda  YSI Inc. 6920.</p>        <p>&nbsp;</p>     <p><font size="3"><b>Resultados</b></font></p>        <p><b><i>Caracterizaci&oacute;n del medio soporte de los reactores</i></b></p>       <p>A partir de los ensayos practicados  a los medios granulares se obtuvieron los siguientes resultados: la arena, cuya  humedad natural fue de 0,13%, present&oacute; una densidad aparente de 2,57 g/ cm<sup>3</sup>;  por su parte, el CAG registr&oacute; una humedad natural de 13,9% y una densidad  aparente de 1,64 g/cm<sup>3</sup>. Con relaci&oacute;n a los datos granulom&eacute;tricos de  la arena, se obtuvieron D10 de 0,16 mm, D30 de 0,24 mm, D50 de 0,31 mm, D60 de  0,34 mm y D90 de 0,54 mm. De la curva granulom&eacute;trica del CAG, se obtuvieron D10  de 0,34 mm, D30 de 0,46 mm, D50 de 0,52 mm, D60 de 0,57 mm y D90 de 0,75 mm.</p>       <p>Con base en las dimensiones de  abertura de tamiz anteriormente descritas se calcularon los coeficientes de  uniformidad, cuyos valores fueron para la arena de 2,13 y para el CAG de 1,68;  de igual manera, se calcularon los coeficientes de curvatura con valores de  1,06 y 1,09 para arena y CAG respectivamente.</p>        ]]></body>
<body><![CDATA[<p><b><i>Ox&iacute;geno disuelto (OD), pH y temperatura</i></b></p>       <p>Durante los experimentos, las  concentraciones de OD medidas en el efluente de los R1 y R2 oscilaron entre 2,0  y 3,5 mg/L, tales valores se debieron a la cantidad de aire necesaria para  mantener en circulaci&oacute;n el medio soporte y al TRH de los reactores. En el R3  las concentraciones efluentes oscilaron entre 5,4 y 10,7 mg/L pues pese al  menor TRH proporcionado, los efluentes de tanques de cultivo poseen bajas  concentraciones de materia org&aacute;nica y valores de OD mayores a 3 mg/L.</p>       <p>Los efluentes de los reactores R1 y  R2 registraron durante los experimentos valores de pH entre 6,7 y 8,2. Por su  parte, en el efluente del R3 los valores medidos variaron entre 7,2 y 8,1.</p>       <p>De acuerdo a la variaci&oacute;n clim&aacute;tica  de las fechas en las que se realizaron los experimentos, las temperaturas  medidas en el R1 y R2 oscilaron entre 19 y 28 &deg;C, y en el R3 entre 16,1 y 24,9  &deg;C.</p>        <p><b><i>F&oacute;sforo Reactivo</i></b></p>      <p><i>Reactor 1</i>. Las concentraciones de f&oacute;sforo  reactivo registradas en el afluente durante las tres fases oscilaron entre 9,3  y 43,2 mg/L y las concentraciones en el efluente variaron entre 7,6 y 26,8 mg/L  tal como puede apreciarse en la <a href="#Figura3">figura 3</a>.</p>      <p align="center"><a name="Figura3"></a><img src="img/revistas/rfiua/n67/n67a15i03.gif"></p>     <p align="center">&nbsp;</p>     <p>En t&eacute;rminos generales, en la  nomenclatura de los reactores de las <a href="#Figura3">figuras 3</a> a <a href="#Figura5">5</a> la letra A representa  valores del afluente; la letra E los valores del efluente; la letra R y el  n&uacute;mero asociado a ella, el reactor utilizado y la letra F y su respectivo  n&uacute;mero se refieren a la fase de estudio reportada por el gr&aacute;fico.</p>      <p align="center"><a name="Figura4"></a><img src="img/revistas/rfiua/n67/n67a15i04.gif"></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="Figura5"></a><img src="img/revistas/rfiua/n67/n67a15i05.gif"></p>     <p align="center">&nbsp;</p>     <p>Las eficiencias medias de remoci&oacute;n  del f&oacute;sforo reactivo por parte del reactor R1, determinadas como el promedio de  las eficiencias registradas en cada uno de los muestreos para cada fase fueron  de 32,6% para la fase 1, 25,6% para la fase 2 y 38,4% para la fase 3. Pese a  que la mayor eficiencia media se obtuvo para la concentraci&oacute;n de medio soporte  de 150 g/L, los resultados muestran que no necesariamente el incremento de  concentraciones se refleje en un incremento de la eficiencia de remoci&oacute;n.</p>       <p><i>Reactor 2</i>. Las concentraciones de P<sub>Reac</sub> en el afluente durante las dos  fases oscilaron entre 14,2 y 43,2 mg/L y las concentraciones en el efluente  variaron entre 9,5 y 22,6 mg/L seg&uacute;n lo ilustra la <a href="#Figura4">figuras 4</a>. Los valores  registrados en el agua residual afluente tanto para el R1 como para el R2  corresponden a las condiciones t&iacute;picas de AR dom&eacute;sticas con alta concentraci&oacute;n  de f&oacute;sforo &#91;31&#93;.</p>       <p>El promedio de las eficiencias de  remoci&oacute;n de P<sub>Reac</sub> en el reactor R2, obtenidas a partir de los datos  de desempe&ntilde;o calculados para los diferentes muestreos de cada fase fueron de  27,5% para la fase 1 y 32,5% para la fase 2. Tales valores sugieren que para la  configuraci&oacute;n geom&eacute;trica del reactor R2, el incremento en la concentraci&oacute;n del  medio soporte se puede ver reflejado en un aumento en la eficiencia de remoci&oacute;n  del f&oacute;sforo.</p>       <p>Tanto las temperaturas como los  valores de pH medidos en los dos reactores se encontraron dentro de los rangos  recomendados para favorecer la remoci&oacute;n biol&oacute;gica de f&oacute;sforo &#91;32&#93;, situaci&oacute;n  similar ocurri&oacute; con las concentraciones de OD, las cuales oscilaron en los  rangos establecidos para zonas aerobias de sistemas EBPR &#91;33&#93;.</p>       <p>Los resultados obtenidos en los  reactores R1 y R2 son consistentes con la eficiencia media de 40% determinada  en la evaluaci&oacute;n del desempe&ntilde;o de reactores similares con di&aacute;metros externo e  interno de 0,25 m y 0,20 m respectivamente; alturas de 6 y 12 metros y TRH's de  4, 6 y 8 horas &#91;34&#93;. Sin embargo, las eficiencias calculadas fueron menores a  las recientemente reportadas para sistemas de tratamiento por reactores <i>airlift</i> loop, que disponen de compartimientos  para generaci&oacute;n de zonas an&oacute;xicas-anaerobias y aerobias as&iacute; como TRH mayores  &#91;35&#93;.</p>        <p><b><i>F&oacute;sforo Total</i></b></p>       <p><i>Reactor 3</i>. Las concentraciones de PT  registradas en el afluente del sedimentador convencional durante la fase  experimental oscilaron entre 0,57 y 3,84 mg/L y las concentraciones medidas en  el efluente del reactor R3 variaron entre 0,48 y 1,53 mg/L tal como puede  apreciarse en la <a href="#Figura5">figura 5</a>.</p>      <p>Los valores de pH y temperatura  medidos en el R3 estuvieron dentro de los rangos recomendados para la remoci&oacute;n  biol&oacute;gica del nutriente; sin embargo, las concentraciones de OD fueron  superiores a las recomendadas para zonas aerobias de sistemas EBPR &#91;36&#93;.</p>       ]]></body>
<body><![CDATA[<p>La eficiencia media de remoci&oacute;n del  f&oacute;sforo total en el reactor R3 asociado al sedimentador convencional, calculada  como el promedio de las eficiencias registradas en los muestreos fue de 32,7%.  La eficiencia obtenida se enmarca dentro de los valores reportados para  reactores de lecho fluidizado bif&aacute;sico (fluidizaci&oacute;n del medio producida por el  flujo del l&iacute;quido a tratar) cuyas eficiencias oscilan entre el 15 y el 41% para  condiciones de TRH entre 11 y 4,75 minutos &#91;37&#93;.</p>       <p>Las eficiencias obtenidas indican  que pudo haber condiciones aerobias y anaerobias en la biopel&iacute;cula formada  alrededor es del medio soporte. Es probable que al evaluar este tipo de  reactores durante periodos de tiempo m&aacute;s extensos se logre un mayor desarrollo  del biofilm que propicie las condiciones que generan competencia por la  utilizaci&oacute;n del sustrato y selecci&oacute;n de los microorganismos acumuladores de  f&oacute;sforo expresadas por la USEPA &#91;38&#93;.</p>       <p>&nbsp;</p>     <p><font size="3"><b>Conclusiones</b> </font></p>        <p>Al tratar efluente dom&eacute;stico en el  reactor con relaci&oacute;n Ae/Ai de 4,0 utilizando arena como medio soporte la  remoci&oacute;n media de f&oacute;sforo reactivo oscil&oacute; entre 25,6 y 38,4%, con mejores  resultados para concentraci&oacute;n de medio soporte de 150 g/L.</p>       <p>En el reactor con relaci&oacute;n Ae/Ai de  2,78 las eficiencias de remoci&oacute;n del f&oacute;sforo activo variaron entre 27,5 y  32,5%, el mejor desempe&ntilde;o se obtuvo para la concentraci&oacute;n 125 g/L de medio  soporte.</p>       <p>El reactor que trat&oacute; efluentes de  producci&oacute;n semi&shy;intensiva de tilapia en un sistema de recirculaci&oacute;n acu&iacute;cola  con relaci&oacute;n Ae/Ai de 6,25 y trabajando con 80 g/L de CAG report&oacute; una  eficiencia media de remoci&oacute;n de f&oacute;sforo total de 32,7%.</p>       <p>Debido a la configuraci&oacute;n compacta,  los bajos TRH requeridos y las eficiencias obtenidas se recomienda el uso de  este tipo de reactores para la remoci&oacute;n de f&oacute;sforo en los tipos de AR estudiadas.</p>       <p>La cantidad de aire necesaria para  fluidizaci&oacute;n y circulaci&oacute;n del medio soporte en los reactores depende de la  densidad del medio soporte y de la concentraci&oacute;n en medio l&iacute;quido, cuanto  mayores sean sus valores, mayores caudales de aire se requieren en el proceso.</p>        <p>&nbsp;</p>       ]]></body>
<body><![CDATA[<p><font size="3"><b>Referencias</b> </font></p>      <!-- ref --><p>1. R. Crites, G.  Tchobanoglous. <i>Small and Decentralized Wastewater Management Systems</i>. Ed. McGraw-Hill. New York. 1998.  pp. 1084.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0120-6230201300020001500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>2. F. Spellman. <i>Handbook of Water  and Wastewater Treatment Plant Operations</i>. 2<sup>nd</sup>  ed. Ed. CRC Press. Boca Raton, FL. 2009. pp. 825.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0120-6230201300020001500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>3. C. Neto, J. Campos. <i>Tratamento de esgotos  sanitarios por processo anaerobio e disposi&ccedil;&agrave;o controlada no solo</i>. In: J. R. Campos (Coord.). Programa de  Pesquisas em  Saneamento B&aacute;sico -  PROSAB. Ed. ABES. Rio de Janeiro. 1999. pp. 1-28.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0120-6230201300020001500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>4. D. Mara. <i>Domestic  Wastewater Treatment in Developing Countries</i>. Ed. Earthscan. London.  Sterling. 2004. pp. 292.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0120-6230201300020001500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>5. F. Spellman. <i>Handbook of Water  and Wastewater Treatment Plant Operations</i>. 2<sup>nd</sup> ed. Ed. CRC  Press. Boca Raton, FL. 2009. pp. 825.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0120-6230201300020001500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>6. S. Cripps, A. Bergheim.  ''Solids management and removal for intensive land-based aquaculture  production systems''. <i>Aquacultural Engineering</i>. Vol. 22. 2000. pp. 33-56.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0120-6230201300020001500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>7. B. True, W. Johnson, S.  Chen. ''Reducing phosphorus discharge from flow-through aquaculture III:  assessing high- rate filtration media for effluent solids and phosphorus  removal''. <i>Aquacultural Engineering</i>. Vol. 32. 2004. pp. 161-170.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0120-6230201300020001500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>8. J. MacMillan, T.  Huddleston, M. Woolley, K. Fothergill. ''Best management practice  development to minimize environmental impact from large flow- through trout  farms''.  <i>Aquaculture</i>.  Vol. 226. 2003. pp. 91-99.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0120-6230201300020001500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>9. A. Bergheim, A. Brinker.  ''Effluent treatment for flow through systems and European Environmental Regulations''. <i>Aquacultural  Engineering</i>.  Vol. 27. 2003. pp. 61-77.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0120-6230201300020001500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>10. B. True, W. Johnson, S.  Chen. ''Reducing phosphorus discharge from flow-through aquaculture III:  assessing high- rate filtration media for effluent solids and phosphorus  removal''. <i>Aquacultural Engineering</i>. Vol. 32. 2004. pp. 161-170.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0120-6230201300020001500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>11. Y. Avnimelech.  ''Bio-filters: The need for a new comprehensive approach''. <i>Aquacultural  Engineering</i>. Vol.  34. 2006. pp. 172-178.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0120-6230201300020001500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>12. M. Timmons, J. Ebeling. <i>Recirculating  Aquaculture. Northeastern  Regional Aquaculture Center</i>. Ithaca. NY. 2010. pp.  948.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0120-6230201300020001500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>13. M. von Sperling. <i>Principios del Tratamiento  Biol&oacute;gico de Aguas Residuales</i>. ''Introducci&oacute;n a la calidad del agua y al  tratamiento de aguas residuales''. 1a edici&oacute;n en espa&ntilde;ol. Vol 1. Editorial  Universitaria, Universidad de Nari&ntilde;o. San Juan de Pasto, Colombia. 2012.  pp. 468.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0120-6230201300020001500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>14. G.V. Levin, J. Shapiro J.  ''Metabolic uptake of phosphorus by wastewater organisms''. <i>Journal of Water  Pollution Control Federation</i>. Vol. 37. 1965. pp. 800-821.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0120-6230201300020001500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>15. L.E. de-Bashan, Y. Bashan.  ''Recent advances in removing phosphorus from wastewater and its future use  as fertilizer (1997-2003)''. <i>Water Research</i>. Vol. 38.  2004. pp. 4222-4246.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0120-6230201300020001500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>16. C. C&aacute;rdenas, T. Perruolo, Y. Tarre, K. Flores, A. Trujillo, L. Saules, I. Araujo, S. Yabroudi. ''Remoci&oacute;n  de nutrientes en un reactor discontinuo secuencial''. <i>Interciencia</i>. Vol. 31. 2006. pp. 787-793.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0120-6230201300020001500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>17. M. Perez, R. Dautant, A.  Contreras, H. Gonzales. <i>Remoci&oacute;n de f&oacute;sforo y nitr&oacute;geno en aguas residuales  utilizando un reactor discontinuo secuencial (SBR)</i>. In: Memorias  XXVIII Congreso Interamericano de Ingenier&iacute;a Sanitaria y Ambiental. Canc&uacute;n.  M&eacute;xico. 27  al 31  de octubre. 2002.  pp. 8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0120-6230201300020001500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>18. M. von Sperling. <i>Principios do  Tratamento Biol&oacute;gico de Aguas Residu&aacute;rias</i>. 'Lodos  ativados''. 2<sup>a</sup> ed. Vol 4. Universidade Federal de Minas Gerais. Belo Horizonte,  Brasil. 2002.  pp. 428.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0120-6230201300020001500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>19. H. Nunes,  J. Tavares de Sousa, B. Ovruski de Ceballos, B. Patricio. ''Remojao  biol&oacute;gica de f&oacute;sforo em reatores em bateladas seq&uuml;enciais com diferentes tempos de retenjao de  s&oacute;lidos''. <i>Eng Sanit Ambient</i>. Vol. 15. 2010. pp. 197-204.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0120-6230201300020001500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>20. L. Lamego,  R Ribeiro da Costa. ''Tratamento de esgoto sanit&aacute;rio em reator h&iacute;brido em  bateladas sequenciais: efici&ecirc;ncia e estabilidade na remo&ccedil;&acirc;o de mat&eacute;ria org&agrave;nica  e nutrientes (N, P)''. <i>Eng. Sanit. Ambient</i>. Vol. 16. 2011. pp. 411-420.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0120-6230201300020001500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>21. D. Patr&iacute;cio. <i>Remo&ccedil;&acirc;o  biol&oacute;gica de mat&eacute;ria org&agrave;nica e nutrientes de esgotos sanit&aacute;rios utilizando  reatores em bateladas seq&uuml;enciais</i>. Disserta&ccedil;ao de Mestrado de Ci&ecirc;ncia e Tecnologia  Ambiental da Universidade Estadual da Para&iacute;ba. 2010. pp. 42-46.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0120-6230201300020001500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>22. C. Henriques, E. Foresti. <i>Remo&ccedil;&acirc;o biol&oacute;gica de f&oacute;sforo em  reator seq&uuml;encial em batelada tratando esgoto sanit&aacute;rio sint&eacute;tico utilizando  acetato de s&oacute;dio como fonte ex&oacute;gena de carbono</i>. In: Memorias XXVIII Congreso  Interamericano de Ingenier&iacute;a Sanitaria y Ambiental. Canc&uacute;n. M&eacute;xico. 2002. pp. 7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0120-6230201300020001500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>23. S. M.  Gonz&aacute;lez, J. Saldarriaga. ''Remoci&oacute;n biol&oacute;gica de materia org&aacute;nica,  nitr&oacute;geno y f&oacute;sforo en un sistema tipo anaerobio-an&oacute;xico-aerobio''. <i>Revista EIA</i>. N&deg;10. 2008. pp. 45-53.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0120-6230201300020001500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>24. J.  Saldarriaga, D. Hoyos, M. Correa. ''Evaluaci&oacute;n de procesos biol&oacute;gicos  unitarios en la remoci&oacute;n simult&aacute;nea de nutrientes para minimizar la  eutrofizaci&oacute;n''. <i>Revista EIA</i>. N&deg; 15. 2011. pp. 129-140.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0120-6230201300020001500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>25. F. Bastos,  M. von Sperling. <i>Nutrientes de esgoto sanit&aacute;rio: utiliza&ccedil;&acirc;o e remo&ccedil;&acirc;o</i>. Projeto PROSAB Ed. ABES. Rio  de Janeiro. Brasil. 2009. pp. 425.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0120-6230201300020001500025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>26. A. Gieseke, P. Arnz, R.  Amann, A. Schramm. ''Simultaneous P and N removal in a sequencing batch  biofilm reactor: insights from reactor and microscale investigations''. <i>Water Research</i>. Vol. 36. 2002. pp. 501-509.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S0120-6230201300020001500026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>       <!-- ref --><p>27. I. S&aacute;nchez, G. Teixeira,  L. Santos, D. Gebara, M. Dall'Aglio S, T. Matsumoto. ''Reactores aer&oacute;bios de lecho fluidizado trif&aacute;sico con  circulaci&oacute;n interna:  caracterizaci&oacute;n hidrodin&aacute;mica y del soporte''. <i>Rev. Fac. Ing.  Univ. Antioquia</i>. N&deg; 56. 2010. pp. 68-77.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S0120-6230201300020001500027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>28. Associa&ccedil;ao  Brasileira  de Normas T&eacute;cnicas- ABNT. <i>NBR 7J8J/84: an&aacute;lise  granulom&eacute;trica: solo</i>. Rio de Janeiro, Brasil. 1984. pp. 13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S0120-6230201300020001500028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>29. Associa&ccedil;ao Brasileira de Normas  T&eacute;cnicas- ABNT. <i>NBR  6508: Determina&ccedil;ao da Massa Espec&iacute;fica: Graos de Solos que Passam na Peneira de  4,9mm</i>.  Rio de Janeiro, Brasil. 1984. pp. 8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000160&pid=S0120-6230201300020001500029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>30. American Public Health  Association (APHA), American Water Works Association (AWWA), Water Environment  Federation (WEF). <i>Standard Methods for the Examination of Water and  Wastewater</i>.  20 Ed. APHA. Washington. 1998. pp. 1325.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000162&pid=S0120-6230201300020001500030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>31. A. Mansur. <i>Sistemas  Econ&oacute;micos de Tratamento de Esgotos Sanit&aacute;rios</i>. Associalo Brasileira  de Engenharia Sanit&agrave;ria e Ambiental - ABES. Rio de  Janeiro, Brasil. 2000.  pp. 192.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000164&pid=S0120-6230201300020001500031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>32. D. Mulkerrins, A.D.W.  Dobson, E. Colleran. ''Parameters affecting biological phosphate removal  from wastewaters''. <i>Environment International</i>. Vol. 30.  2004. pp. 249-259.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000166&pid=S0120-6230201300020001500032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>33. M. von Sperling. <i>Principios do Tratamento Biol&oacute;gico de  Aguas Residu&aacute;rias</i>. 'Lodos ativados''. 2<sup>a</sup> ed. Vol 4. Universidade  Federal de Minas Gerais. Belo Horizonte, Brasil. 2002. pp. 428.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000168&pid=S0120-6230201300020001500033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <p>34. D. Gebara. <i>Desempenho de um reator aer&oacute;bio  de leito fluidizado no tratamento de esgoto sanit&agrave;rio</i>. Tese de  Doutorado em Engenharia. Escola Polit&eacute;cnica, Universidade de Sao Paulo (USP). Sao Paulo, Brasil. 2006. pp. 402.</p>       <!-- ref --><p>35. M. Jiang,  Y. Zhang, X. Zhou, Y. Su, M. Zhang, K. Zhang. ''Simultaneous carbon and  nutrient removal in an airlift loop reactor under a limited filamentous bulking  state''.  <i>Bioresource Technology</i>. Vol. 130. 2013. pp. 406-411.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000171&pid=S0120-6230201300020001500034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       ]]></body>
<body><![CDATA[<p>36. S. Rybicki. <i>Advanced  Wastewater Treatment Report No 1</i>. ''Phosphorus Removal From Wastewater A Literature  Review''. Division of Water Resources Engineering, Department of Civil and  Environmental Engineering, Royal Institute of Technology. Stockholm, Sweden. 1997.  pp. 106.</p>       <!-- ref --><p>37. J. Davidson, N. Helwig, S.  Summerfelt. ''Fluidized sand biofilters used to remove ammonia, biochemical  oxygen demand, total coliform bacteria, and suspended solids from an intensive  aquaculture effluent''. <i>Aquacultural Engineering</i>. Vol. 39. 2008. pp. 6-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000174&pid=S0120-6230201300020001500035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>38. United States Environmental  Protection Agency (USEPA). <i>Design Manual, Phosphorus Removal</i>. Ed. Office of research and  development. Cincinatti, USA. 1987. pp.1-116.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000176&pid=S0120-6230201300020001500036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>        <p>&nbsp;</p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Crites]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Tchobanoglous]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[Small and Decentralized Wastewater Management Systems]]></source>
<year>1998</year>
<page-range>1084</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Ed. McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Spellman]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<source><![CDATA[Handbook of Water and Wastewater Treatment Plant Operations]]></source>
<year>2009</year>
<edition>2</edition>
<page-range>825</page-range><publisher-loc><![CDATA[Boca Raton^eFL FL]]></publisher-loc>
<publisher-name><![CDATA[Ed. CRC Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neto]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Campos]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Tratamento de esgotos sanitarios por processo anaerobio e disposiçào controlada no solo]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Campos]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Programa de Pesquisas em Saneamento Básico - PROSAB]]></source>
<year>1999</year>
<page-range>1-28</page-range><publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
<publisher-name><![CDATA[Ed. ABES]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mara]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[Domestic Wastewater Treatment in Developing Countries]]></source>
<year>2004</year>
<page-range>292</page-range><publisher-loc><![CDATA[London^eSterling Sterling]]></publisher-loc>
<publisher-name><![CDATA[Ed. Earthscan]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Spellman]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<source><![CDATA[Handbook of Water and Wastewater Treatment Plant Operations]]></source>
<year>2009</year>
<edition>2</edition>
<page-range>825</page-range><publisher-loc><![CDATA[Boca Raton^eFL FL]]></publisher-loc>
<publisher-name><![CDATA[Ed. CRC Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cripps]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bergheim]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solids management and removal for intensive land-based aquaculture production systems]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2000</year>
<volume>22</volume>
<page-range>33-56</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[True]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reducing phosphorus discharge from flow-through aquaculture III: assessing high- rate filtration media for effluent solids and phosphorus removal]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2004</year>
<volume>32</volume>
<page-range>161-170</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MacMillan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Huddleston]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Woolley]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fothergill]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Best management practice development to minimize environmental impact from large flow- through trout farms]]></article-title>
<source><![CDATA[Aquaculture]]></source>
<year>2003</year>
<volume>226</volume>
<page-range>91-99</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergheim]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brinker]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effluent treatment for flow through systems and European Environmental Regulations]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2003</year>
<volume>27</volume>
<page-range>61-77</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[True]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reducing phosphorus discharge from flow-through aquaculture III: assessing high- rate filtration media for effluent solids and phosphorus removal]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2004</year>
<volume>32</volume>
<page-range>161-170</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Avnimelech]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bio-filters: The need for a new comprehensive approach]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2006</year>
<volume>34</volume>
<page-range>172-178</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Timmons]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ebeling]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Recirculating Aquaculture. Northeastern Regional Aquaculture Center]]></source>
<year>2010</year>
<page-range>948</page-range><publisher-loc><![CDATA[Ithaca^eNY NY]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Principios del Tratamiento Biológico de Aguas Residuales. ''Introducción a la calidad del agua y al tratamiento de aguas residuales'']]></source>
<year>2012</year>
<volume>1</volume>
<edition>1</edition>
<page-range>468</page-range><publisher-loc><![CDATA[San Juan de Pasto ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Universitaria, Universidad de Nariño]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Levin]]></surname>
<given-names><![CDATA[G.V]]></given-names>
</name>
<name>
<surname><![CDATA[Shapiro J]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metabolic uptake of phosphorus by wastewater organisms]]></article-title>
<source><![CDATA[Journal of Water Pollution Control Federation]]></source>
<year>1965</year>
<volume>37</volume>
<page-range>800-821</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[de-Bashan]]></surname>
<given-names><![CDATA[L.E]]></given-names>
</name>
<name>
<surname><![CDATA[Bashan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recent advances in removing phosphorus from wastewater and its future use as fertilizer (1997-2003)]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2004</year>
<volume>38</volume>
<page-range>4222-4246</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Perruolo]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Tarre]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Trujillo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Saules]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Araujo]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Yabroudi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Remoción de nutrientes en un reactor discontinuo secuencial]]></article-title>
<source><![CDATA[Interciencia]]></source>
<year>2006</year>
<volume>31</volume>
<page-range>787-793</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Perez]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Dautant]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Contreras]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzales]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<source><![CDATA[Remoción de fósforo y nitrógeno en aguas residuales utilizando un reactor discontinuo secuencial (SBR)]]></source>
<year></year>
<conf-name><![CDATA[XXVIII Congreso Interamericano de Ingeniería Sanitaria y Ambiental]]></conf-name>
<conf-date>27 al 31 de octubre. 2002</conf-date>
<conf-loc>Cancún </conf-loc>
<page-range>8</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Principios do Tratamento Biológico de Aguas Residuárias. 'Lodos ativados'']]></source>
<year>2002</year>
<volume>4</volume>
<edition>2</edition>
<page-range>428</page-range><publisher-loc><![CDATA[Belo Horizonte ]]></publisher-loc>
<publisher-name><![CDATA[Universidade Federal de Minas Gerais]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nunes]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tavares de Sousa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ovruski de Ceballos]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Patricio]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Remojao biológica de fósforo em reatores em bateladas seqüenciais com diferentes tempos de retenjao de sólidos]]></article-title>
<source><![CDATA[Eng Sanit Ambient]]></source>
<year>2010</year>
<volume>15</volume>
<page-range>197-204</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lamego]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ribeiro da Costa]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Tratamento de esgoto sanitário em reator híbrido em bateladas sequenciais: eficiência e estabilidade na remoçâo de matéria orgànica e nutrientes (N, P)]]></article-title>
<source><![CDATA[Eng. Sanit. Ambient]]></source>
<year>2011</year>
<volume>16</volume>
<page-range>411-420</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Patrício]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[Remoçâo biológica de matéria orgànica e nutrientes de esgotos sanitários utilizando reatores em bateladas seqüenciais]]></source>
<year>2010</year>
<page-range>42-46</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henriques]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Foresti]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Remoçâo biológica de fósforo em reator seqüencial em batelada tratando esgoto sanitário sintético utilizando acetato de sódio como fonte exógena de carbono]]></source>
<year>2002</year>
<conf-name><![CDATA[XXVIII Congreso Interamericano de Ingeniería Sanitaria y Ambiental]]></conf-name>
<conf-loc> </conf-loc>
<page-range>7</page-range><publisher-loc><![CDATA[Cancún ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[S. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Saldarriaga]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[''Remoción biológica de materia orgánica, nitrógeno y fósforo en un sistema tipo anaerobio-anóxico-aerobio'']]></article-title>
<source><![CDATA[Revista EIA]]></source>
<year>2008</year>
<volume>10</volume>
<page-range>45-53</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saldarriaga]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Hoyos]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[''Evaluación de procesos biológicos unitarios en la remoción simultánea de nutrientes para minimizar la eutrofización'']]></article-title>
<source><![CDATA[Revista EIA.]]></source>
<year>2011</year>
<volume>15</volume>
<page-range>129-140</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bastos]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Nutrientes de esgoto sanitário: utilizaçâo e remoçâo]]></source>
<year>2009</year>
<page-range>425</page-range><publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gieseke]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Arnz]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Amann]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Schramm]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simultaneous P and N removal in a sequencing batch biofilm reactor: insights from reactor and microscale investigations]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2002</year>
<volume>36</volume>
<page-range>501-509</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Teixeira]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Gebara]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Dall'Aglio S]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Matsumoto]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[''Reactores aeróbios de lecho fluidizado trifásico con circulación interna: caracterización hidrodinámica y del soporte'']]></article-title>
<source><![CDATA[Rev. Fac. Ing. Univ. Antioquia.]]></source>
<year>2010</year>
<volume>56</volume>
<page-range>68-77</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="">
<collab>Associaçao Brasileira de Normas Técnicas- ABNT</collab>
<source><![CDATA[NBR 7J8J/84: análise granulométrica: solo]]></source>
<year>1984</year>
<page-range>13</page-range><publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="">
<collab>Associaçao Brasileira de Normas Técnicas- ABNT</collab>
<source><![CDATA[NBR 6508: Determinaçao da Massa Específica: Graos de Solos que Passam na Peneira de 4,9mm]]></source>
<year>1984</year>
<page-range>8</page-range><publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="book">
<collab>American Public Health Association (APHA), American Water Works Association (AWWA), Water Environment Federation (WEF)</collab>
<source><![CDATA[Standard Methods for the Examination of Water and Wastewater]]></source>
<year>1998</year>
<edition>20</edition>
<page-range>1325</page-range><publisher-loc><![CDATA[^eWashington Washington]]></publisher-loc>
<publisher-name><![CDATA[APHA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mansur]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Sistemas Económicos de Tratamento de Esgotos Sanitários]]></source>
<year>2000</year>
<page-range>192</page-range><publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
<publisher-name><![CDATA[Associalo Brasileira de Engenharia Sanitària e Ambiental - ABES]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mulkerrins]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[A.D.W]]></given-names>
</name>
<name>
<surname><![CDATA[Colleran]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Parameters affecting biological phosphate removal from wastewaters]]></article-title>
<source><![CDATA[Environment International]]></source>
<year>2004</year>
<volume>30</volume>
<page-range>249-259</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Principios do Tratamento Biológico de Aguas Residuárias. 'Lodos ativados''.]]></source>
<year>2002</year>
<volume>4</volume>
<edition>2ª</edition>
<page-range>428</page-range><publisher-loc><![CDATA[Belo Horizonte ]]></publisher-loc>
<publisher-name><![CDATA[Universidade Federal de Minas Gerais]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B34">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simultaneous carbon and nutrient removal in an airlift loop reactor under a limited filamentous bulking state]]></article-title>
<source><![CDATA[Bioresource Technology]]></source>
<year>2013</year>
<volume>130</volume>
<page-range>406-411</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Davidson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Helwig]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Summerfelt]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fluidized sand biofilters used to remove ammonia, biochemical oxygen demand, total coliform bacteria, and suspended solids from an intensive aquaculture effluent]]></article-title>
<source><![CDATA[Aquacultural Engineering]]></source>
<year>2008</year>
<volume>39</volume>
<page-range>6-15</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>38</label><nlm-citation citation-type="book">
<collab>United States Environmental Protection Agency (USEPA)</collab>
<source><![CDATA[Design Manual, Phosphorus Removal]]></source>
<year>1987</year>
<page-range>1-116</page-range><publisher-loc><![CDATA[Cincinatti ]]></publisher-loc>
<publisher-name><![CDATA[Ed. Office of research and development]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>