<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-9957</journal-id>
<journal-title><![CDATA[Revista colombiana de Gastroenterología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Col Gastroenterol]]></abbrev-journal-title>
<issn>0120-9957</issn>
<publisher>
<publisher-name><![CDATA[Asociación Colombiana de Gastroenterología  ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-99572015000200006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Stents autoexpandibles biodegradables en endoscopia intervencionista gastrointestinal y pancreatobiliar: Estado actual]]></article-title>
<article-title xml:lang="en"><![CDATA[The Current State of Biodegradable Self-expanding Stents in Interventional Gastrointestinal and Pancreatobiliary Endoscopy]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Álvarez B]]></surname>
<given-names><![CDATA[Óscar A]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castaño Llano]]></surname>
<given-names><![CDATA[Rodrigo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[David]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Texas  ]]></institution>
<addr-line><![CDATA[Harlingen Texas]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Grupo de Gastrohepatología ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad CES Medicina ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>30</day>
<month>06</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>30</day>
<month>06</month>
<year>2015</year>
</pub-date>
<volume>30</volume>
<numero>2</numero>
<fpage>178</fpage>
<lpage>186</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-99572015000200006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-99572015000200006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-99572015000200006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los stents biodegradables son una opción muy atractiva para utilizar en pacientes con estenosis benignas recurrentes/recalcitrantes del tracto digestivo y biliar. En teoría, utilizando estos stents biodegradables, se pueden evitar dilataciones repetitivas de estenosis digestivas o biliares refractarias al manejo convencional, como también se podrían evitar resecciones quirúrgicas, principalmente en pacientes de alto riesgo quirúrgico, y se minimiza el número de procedimientos endoscópicos intervencionistas]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Biodegradable stents are a very attractive option for use in patients with benign but recurrent and recalcitrant digestive tract and biliary strictures. In theory, use of these biodegradable stents mitigates the need for repetitive expansion of digestive or biliary strictures which are refractory to conventional management and avoids the need of surgical resection. This is especially true for patients at high surgical risk. Stents can also minimize the number of interventional endoscopic procedures performed on a patient]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Stent reabsorbible]]></kwd>
<kwd lng="es"><![CDATA[estenosis biliares benignas]]></kwd>
<kwd lng="es"><![CDATA[estenosis colónicas benignas]]></kwd>
<kwd lng="es"><![CDATA[estenosis gastroduodenales benignas]]></kwd>
<kwd lng="en"><![CDATA[Reabsorbable stent]]></kwd>
<kwd lng="en"><![CDATA[benign biliary stenoses]]></kwd>
<kwd lng="en"><![CDATA[benign colon stenoses]]></kwd>
<kwd lng="en"><![CDATA[benign gastroduodenal stenoses]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <FONT FACE="Verdana" SIZE=4>    <p align="center"><b>Stents autoexpandibles biodegradables en endoscopia   intervencionista gastrointestinal y pancreatobiliar. Estado actual</b></p></FONT> <FONT FACE="Verdana" SIZE=2>    <p align="center">&Oacute;scar A. &Aacute;lvarez B. MD. (1), Rodrigo Casta&ntilde;o Llano MD. (2),   David Restrepo (3)</p>     <p>(1) Radi&oacute;logo. Internista. Gastroenter&oacute;logo. Profesor,   Universidad de Texas, Campo Regional, San Antonio. Director, Gastroenterolog&iacute;a,   VA Texas Valley Coastal Bend. Harlingen, Texas.</p>     <p>(2) Cirug&iacute;a Gastrointestinal y Endoscopia. Jefe, Posgrado de   Cirug&iacute;a General, UPB. Grupo de Gastrohepatolog&iacute;a, Universidad de Antioquia.   Instituto de Cancerolog&iacute;a Cl&iacute;nica las Am&eacute;ricas. Medell&iacute;n, Colombia.</p>     <p>(3) Estudiante de Medicina, Universidad CES. Medell&iacute;n,   Colombia.</p>     <p>Fecha recibido:    08-07-14  Fecha aceptado:  06-04-15</p>     <p><b>Resumen</b></p>     <p>Los stents biodegradables son una opci&oacute;n muy atractiva para   utilizar en pacientes con estenosis benignas recurrentes/recalcitrantes del   tracto digestivo y biliar. En teor&iacute;a, utilizando estos stents biodegradables,   se pueden evitar dilataciones repetitivas de estenosis digestivas o biliares   refractarias al manejo convencional, como tambi&eacute;n se podr&iacute;an evitar resecciones   quir&uacute;rgicas, principalmente en pacientes de alto riesgo quir&uacute;rgico, y se   minimiza el n&uacute;mero de procedimientos endosc&oacute;picos intervencionistas.</p>     <p><b>Palabras clave</b></p>     ]]></body>
<body><![CDATA[<p>Stent reabsorbible, estenosis biliares benignas, estenosis   col&oacute;nicas benignas, estenosis gastroduodenales benignas.</p>     <p><b>INTRODUCCI&Oacute;N</b></p>     <p>El uso de stents met&aacute;licos autoexpandibles ha demostrado ser   un tratamiento efectivo para manejar las estenosis benignas refractarias y   malignas del tracto digestivo. Sin embargo, el uso de estos stents,   principalmente en el escenario de las patolog&iacute;as benignas, est&aacute; asociado con   varios tipos de complicaciones como son las dificultades al momento de la   extracci&oacute;n, la migraci&oacute;n y la hiperplasia y tambi&eacute;n est&aacute; relacionado con los   costos inherentes de procedimientos endosc&oacute;picos repetitivos (1-3). Los stents   pl&aacute;sticos se asocian con una mayor tasa de migraci&oacute;n, una menor flexibilidad y   una menor fuerza radial expansiva (4, 5).</p>     <p>En las &uacute;ltimas dos d&eacute;cadas se han hecho avances muy   significativos en el desarrollo de materiales biocompatibles y biodegradables   para la aplicaci&oacute;n m&eacute;dica. Es as&iacute; como se han logrado desarrollar los stents   biodegradables con el fin de intentar remediar los problemas ya mencionados   (6). El presente art&iacute;culo revisa la experiencia acumulada hasta la fecha, que   no es mucha y es poco conocida, y se hace &eacute;nfasis en los aspectos biomec&aacute;nicos   con la intenci&oacute;n de considerar una futura implementaci&oacute;n local.</p>     <p><b>BIOMATERIALES</b></p>     <p>Un biomaterial es un compuesto inerte dise&ntilde;ado para ser   implantado o incorporado dentro de un sistema biol&oacute;gico vivo. Los biomateriales   son sometidos a situaciones adversas, dado que est&aacute;n expuestos de modo temporal   o permanente a fluidos del cuerpo, donde se da la corrosi&oacute;n de los componentes   del implante. Los biomateriales pueden restituir funciones de tejidos vivos y   &oacute;rganos en el cuerpo. Por tanto, es esencial entender las relaciones existentes   entre las propiedades, funciones y estructuras de los materiales biol&oacute;gicos,   dado que las propiedades requeridas de un material var&iacute;an de acuerdo con la   aplicaci&oacute;n particular. Los biomateriales pueden ser: 1) inertes, ya que no   desencadenan ninguna reacci&oacute;n en el hu&eacute;sped; 2) bioactivos, asegurando as&iacute; un desempe&ntilde;o   estable y duradero; y 3) biodegradables, que pueden ser degradados qu&iacute;micamente   o descompuestos por factores naturales como las bacterias. Es de vital   importancia que estos materiales biodegradables de uso m&eacute;dico no tengan riesgo   de carcinog&eacute;nesis, inmunogenicidad, teratogenicidad y toxicidad (7).</p>     <p>Los biomateriales m&aacute;s usados son las aleaciones a base de   magnesio y pol&iacute;meros sint&eacute;ticos tales como: &aacute;cido polil&aacute;ctico, &aacute;cido poliglic&oacute;lico, policaprolactona, polidioxanona y   polil&aacute;ctico coglic&oacute;lido (8-10). Los biomateriales hechos de aleaciones a base   de magnesio son de alta biocompatibilidad y tienen la propiedad de disolverse   en el cuerpo humano durante el proceso de degradaci&oacute;n. Sin embargo, debido a su   alta corrosi&oacute;n, la degradaci&oacute;n ocurre antes de culminar su objetivo.</p>     <p>Los biomateriales de naturaleza polim&eacute;rica tienen la ventaja   de ser el&aacute;sticos, de baja densidad y relativamente f&aacute;ciles de fabricar. Los   pol&iacute;meros que se utilizan en los implementos m&eacute;dicos se degradan m&aacute;s lentamente   que las aleaciones de magnesio y su degradaci&oacute;n es hidrol&iacute;tica. Este proceso de   hidr&oacute;lisis degrada los pol&iacute;meros en mol&eacute;culas de bajo peso molecular, las   cuales pueden ser metabolizadas por el organismo.</p>     <p>El pol&iacute;mero ideal para ser utilizado en los stents   biodegradables debe: 1) mantener una fuerza expansiva suficiente hasta que la   estenosis quede resuelta; 2) ser no t&oacute;xicos; 3) que no induzca una respuesta   inflamatoria en el tejido vecino; 4) metabolizarse en el cuerpo despu&eacute;s de   cumplir su funci&oacute;n; 4) ser f&aacute;cilmente procesado y que no deje trazas; y 5) ser   f&aacute;cil de esterilizar. Teniendo en cuenta estas caracter&iacute;sticas, las principales   ventajas de un pol&iacute;mero sint&eacute;tico son: 1) adecuada biocompatibilidad; 2) la   posibilidad de cambiar en composici&oacute;n y en las propiedades fisicomec&aacute;nicas; 3)   tener un coeficiente de baja fricci&oacute;n; 4) facilidad de ser procesado y   viabilidad; 5) alternativa de cambio qu&iacute;mico y f&iacute;sico en la superficie; y 6)   habilidad de inmovilizar c&eacute;lulas o biomol&eacute;culas dentro de ellos o en su   superficie (esta &uacute;ltima caracter&iacute;stica llev&oacute; al descubrimiento de los stents   con liberaci&oacute;n de f&aacute;rmacos, como lo son algunos stents coronarios). Los   pol&iacute;meros biodegradables usados para la liberaci&oacute;n de f&aacute;rmacos representan un   gran avance tecnol&oacute;gico y se vienen utilizando principalmente en el sistema   vascular con el uso de stents coronarios (11).</p>     <p>La necesidad generada por el desarrollo de f&aacute;rmacos que no   pueden ser administrados por las v&iacute;as tradicionales, intramuscular, subcut&aacute;nea   o endovenosa, y la frecuente conveniencia de suministrar un f&aacute;rmaco de manera   localizada y controlada en el lugar donde debe ejercer su acci&oacute;n, han promovido   un &aacute;rea de investigaci&oacute;n y desarrollo de biomateriales dentro del campo de la   farmacia. Por ejemplo, en la elaboraci&oacute;n de dispositivos que incorporan un   f&aacute;rmaco en una matriz bioabsorbible, la liberaci&oacute;n y consiguiente   disponibilidad del f&aacute;rmaco est&aacute; determinada por la velocidad con que se degrada   el pol&iacute;mero que la contiene (12). Los stents coronarios son un gran ejemplo. Se   han implementado diferentes compuestos en la matriz del stent biodegradable,   con el objeto de evitar la reacci&oacute;n intimal, tales como el tacrolimus, el   sirolimus, el paclitaxel, la aspirina, la dexametasona (13, 14) e incluso   material radioactivo para prevenir la reestenosis e inflamaci&oacute;n (15). Hasta la   fecha, no hay ninguna aplicaci&oacute;n similar en el &aacute;rea gastroenterol&oacute;gica en   humanos (<a href="#figura1">figura 1</a>).</p>     ]]></body>
<body><![CDATA[<p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f1.jpg" width="430" height="202"><a name="figura1"></a></p>     <p>El mecanismo de acci&oacute;n de los pol&iacute;meros var&iacute;a seg&uacute;n sean o   no biodegradables. Aunque toda la materia se degrada con el paso del tiempo, el   t&eacute;rmino biodegradable aplicado a los pol&iacute;meros implica que este se elimina en   un corto per&iacute;odo. Los poli&eacute;steres son los pol&iacute;meros sint&eacute;ticos biodegradables   de uso comercial que tienen mayor aplicaci&oacute;n en el campo m&eacute;dico. Se   caracterizan por la presencia de enlaces &eacute;ster en la cadena principal, lo cual   permite que sean degradados hidrol&iacute;ticamente. Los procesos de hidr&oacute;lisis   degradan los pol&iacute;meros en mol&eacute;culas de bajo peso molecular que pueden ser   metabolizadas por el organismo. El medio fisiol&oacute;gico humano re&uacute;ne las   condiciones apropiadas para que estos procesos se produzcan en condiciones   normales a un pH entre 7 y 7,4 (16).</p>     <p>Como se describi&oacute;, los stents biodegradables son hechos de   varios pol&iacute;meros sint&eacute;ticos tales como &aacute;cido polil&aacute;ctico, poliglicolato o &aacute;cido poliglic&oacute;lico, poli-L- l&aacute;ctico (<a href="#figura2">figura 2</a>) y copol&iacute;meros   de &aacute;cido polil&aacute;ctico-coglic&oacute;lico y polidioxanona (<a href="#figura3">figura 3</a>) (17). Los stents   biodegradables han sido utilizados en el tratamiento de estenosis benignas   refractarias tales como ureterales, uretrales, traqueales, biliares,   pancre&aacute;ticas, intestino delgado, colon y estenosis esof&aacute;gicas (18).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f2.jpg" width="430" height="183"><a name="figura2"></a></p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f3.jpg" width="430" height="305"><a name="figura3"></a></p>     <p><b>EXPERIENCIA CL&Iacute;NICA CON LOS STENTS GASTROINTESTINALES Y   PANCREATOBILIARES BIODEGRADABLES</b></p>     <p>La idea de utilizar stents biodegradables no es nueva; ya   entre 1991 y 1992 hab&iacute;a prototipos experimentales. No obstante, solo en los   &uacute;ltimos a&ntilde;os se dispuso de modelos que superaron la fase experimental en   animales y comenzaron a ser tan seguros como para ser probados en seres   humanos.</p>     <p>En 1993, Kemppainen public&oacute; el primer estudio de stents   biodegradables, en el que utiliz&oacute; un modelo experimental de estenosis uretral   en conejos tratados con un stent biodegradable hecho de &aacute;cido poli-L-l&aacute;ctico.   En este estudio, los autores concluyeron que este tipo de stent ten&iacute;a un gran   futuro para prevenir la reestenosis de las estrecheces uretrales (19).</p>     <p>En el tracto gastrointestinal los primeros stents   biodegradables fueron hechos de &aacute;cido polil&aacute;ctico y desarrollados por Goldin   (20), quien reporto la experiencia con 5 pacientes que ten&iacute;an estenosis   esof&aacute;gica benigna refractaria al tratamiento endosc&oacute;pico (<a href="#figura4">figura 4</a>). Los   autores concluyeron que este prototipo de stent no fue capaz de mantener una   fuerza radial significativa y sostenida por m&aacute;s de 3 semanas. El stent se   desintegr&oacute; en un lapso de 6 semanas despu&eacute;s de la colocaci&oacute;n e indujo la   obstrucci&oacute;n del lumen esof&aacute;gico. Estos hallazgos fueron confirmados en otro   estudio realizado por Fry &amp; Fleisher (21).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f4.jpg" width="430" height="292"><a name="figura4"></a></p>     ]]></body>
<body><![CDATA[<p>Los stents biodegradables hechos de polidioxanona han   mejorado los resultados ostensiblemente (<a href="#figura5">figura 5</a>).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f5.jpg" width="580" height="156"><a name="figura5"></a></p>     <p>Este tipo de stent tiene una mayor integridad y conserva una   fuerza radial que es mantenida durante 6 a 8 semanas despu&eacute;s de la colocaci&oacute;n,   como lo pudo demostrar Rejchrt (22). En este estudio piloto de tres pacientes   con estenosis benigna del intestino delgado y del colon, los autores   confirmaron que la degradaci&oacute;n y fragmentaci&oacute;n del stent ocurre entre las 11-12   semana despu&eacute;s de colocado el stent. Parece ser que la degradaci&oacute;n del stent es   dependiente del pH y es m&aacute;s r&aacute;pida la degradaci&oacute;n cuando el pH es m&aacute;s bajo. Es   posible que estas observaciones preliminares donde se present&oacute; una dilataci&oacute;n   prolongada antes de la degradaci&oacute;n y absorci&oacute;n del stent puedan representar una   soluci&oacute;n para pacientes con estenosis benignas refractarias a la dilataci&oacute;n   convencional. Este nuevo tipo de stent biodegradable permite una dilataci&oacute;n   radial constante que es similar a la que se logra con los stents met&aacute;licos   expandibles, con la salvedad que el stent biodegradable no necesita ser   removido. El stent biodegradable de polidioxanona puede ser una alternativa de   tratamiento para las estenosis benignas refractarias del tracto digestivo.</p>     <p>Parviainen manej&oacute; dos anastomosis pancreatoyeyunales en   forma profil&aacute;ctica con stents biodegradables de polilactida. Ninguno de estos   pacientes desarroll&oacute; complicaciones en el posoperatorio. Dichos stents se   degradan m&aacute;s f&aacute;cilmente en el medio pancre&aacute;tico que en el biliar (23).</p>     <p><b>Es&oacute;fago</b></p>     <p>La colocaci&oacute;n de stents biodegradables es una alternativa   para el tratamiento de las estenosis esof&aacute;gicas benignas refractarias al   tratamiento convencional con dilataci&oacute;n. Tambi&eacute;n podr&iacute;a ser una alternativa a   considerar en pacientes con acalasia. Dichas estenosis esof&aacute;gicas generalmente   est&aacute;n relacionadas con el reflujo gastroesof&aacute;gico, la ingesti&oacute;n de c&aacute;usticos,   el posoperatorio de cirug&iacute;a esof&aacute;gica, y son secundarias a la radiaci&oacute;n (18).   El tratamiento convencional de estas estenosis es con dilataciones utilizando   los dilatadores tipo buj&iacute;a o con balones hidrost&aacute;ticos. Este tipo de tratamiento   est&aacute; asociado con una mejor&iacute;a cl&iacute;nica inmediata de la disfagia en un 80%-90% de   los casos. Sin embargo, un 30% a 60% de las estenosis benignas puede recurrir a   corto y largo plazo. Este tipo de pacientes con estenosis benignas recurrentes   y recalcitrantes al tratamiento convencional son los que se pueden beneficiar   de un tratamiento alternativo y los stents biodegradables fueron desarrollados   para ser considerados en este grupo especial de pacientes (24). Saito report&oacute;   los resultados de dos series de pacientes los cuales fueron tratados con stents   hechos de &aacute;cido polil&aacute;ctico (<a href="#figura6">figura 6</a>). El 77% de estos stents migr&oacute; en un per&iacute;odo   de 10 a 21 d&iacute;as despu&eacute;s de colocados. Sin embargo, se observ&oacute; un &eacute;xito cl&iacute;nico   en todos los pacientes por un per&iacute;odo de 7 meses a 2 a&ntilde;os (10).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f6.jpg" width="580" height="192"><a name="figura6"></a></p>     <p>En el 2007 se comenz&oacute; a utilizar el stent de ELLA (ELLA-Cs,   Hradec Kralove, Rep&uacute;blica Checa). Dicho stent biodegradable es hecho del   pol&iacute;mero polidioxanona y es en la actualidad el &uacute;nico stent biodegradable   utilizado en el tracto digestivo. El stent est&aacute; ensamblado en un introductor   28F y viene en diferentes tama&ntilde;os entre 18 y 25 mm. Es manufacturado para uso   comercial y est&aacute; hecho de polidioxanona, que es un pol&iacute;mero biodegradable   semicristalino y se degrada por hidr&oacute;lisis. Los productos de biodegradaci&oacute;n no   son t&oacute;xicos. El stent es radiotransparente y tiene marcas radiopacas en el   extremo proximal y distal (<a href="#figura7">figura 7</a>) (25).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f7.jpg" width="580" height="215"><a name="figura7"></a></p>     <p>El estudio publicado por Rejchrt (25) en 2009 con el stent   de polidioxanona demostr&oacute; que la fuerza radial e integridad del stent fueron   mantenidas de una forma continua al menos por 6 semanas despu&eacute;s de la   colocaci&oacute;n. Esto es mucho mejor que la experiencia publicada anteriormente con   otros stents biodegradables. El 60% de la degradaci&oacute;n del stent ocurre entre   las semanas 7 y 9 despu&eacute;s de colocado y un 90% de degradaci&oacute;n a las 9 semanas.   Se recomienda tratamiento supresor del &aacute;cido ya que se ha demostrado que la   degradaci&oacute;n de este tipo de stent es m&aacute;s r&aacute;pida con la exposici&oacute;n al &aacute;cido. El   tiempo promedio de degradaci&oacute;n de este tipo de stent ocurre entre las 11 y 12   semanas (<a href="#figura8">figura 8</a>).</p>     ]]></body>
<body><![CDATA[<p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f8.jpg" width="580" height="245"><a name="figura8"></a></p>     <p>Se ha publicado en varios estudios la experiencia con los stents   biodegradables de polidioxanona SX-ELLA en el tratamiento de pacientes con   estenosis benignas refractarias del es&oacute;fago (16, 18, 25-31) as&iacute; como en la   acalasia (32). El &eacute;xito t&eacute;cnico, la respuesta cl&iacute;nica y las complicaciones   var&iacute;an de acuerdo con el estudio. La colocaci&oacute;n del stent no fue un problema   para todos los casos reportados. El &eacute;xito cl&iacute;nico var&iacute;a desde un 0% hasta un   100%, con un promedio del 40% (33-35). Repici (31) public&oacute; en el 2010 un   estudio prospectivo de dos centros europeos. En este estudio se utilizaron stents   biodegradables en 21 pacientes con estenosis esof&aacute;gicas refractarias al   tratamiento endosc&oacute;pico. Todos los pacientes fueron tratados con el stent ELLA   (ELLA-CS, Hradec Kralove, Rep&uacute;blica Checa) La colocaci&oacute;n de los stents fue   exitosa en el 100% de los casos. La migraci&oacute;n del stent ocurri&oacute; en solo 2   pacientes despu&eacute;s de varias semanas de la colocaci&oacute;n. La biodegradaci&oacute;n del stent   ocurri&oacute; en 3 a 6 meses. La endoscopia de seguimiento a los 3 meses mostr&oacute; que   todos los stents estaban fragmentados y la endoscopia de seguimiento a los 6   meses demostr&oacute; que todos los stents se hab&iacute;an disuelto. Al final del   seguimiento, 9 pacientes de 20 (45%) tuvieron resoluci&oacute;n de la disfagia. Para   tener en consideraci&oacute;n, la frecuencia de dilataciones endosc&oacute;picas fue menor en   los pacientes en quienes fall&oacute; el tratamiento con el stent. La serie con el   mayor seguimiento a largo plazo con el uso de este tipo de stent fue reportada   por Hirdes. En esta serie de 28 pacientes se alcanz&oacute; un &eacute;xito cl&iacute;nico del 25%   (28).</p>     <p>Los stents biodegradables te&oacute;ricamente ser&iacute;an el tratamiento   ideal para las estenosis benignas refractarias al tratamiento endosc&oacute;pico.   Dichos stents pueden proporcionar una permeabilidad temporal conjuntamente con   una remodelaci&oacute;n de la zona de estenosis. La eficacia temporal de los stents   biodegradables parte de un concepto simple en el cual una estenosis que   necesita dilataci&oacute;n repetitiva responder&aacute; a una dilataci&oacute;n prolongada con el   uso de una endopr&oacute;tesis que se dejar&aacute; in situ por varias semanas o meses. El   principio fundamental es obtener una remodelaci&oacute;n de la estenosis fibr&oacute;tica   utilizando un stent hecho de materiales altamente biocompatibles que no   induzcan un da&ntilde;o mec&aacute;nico o irritativo que pueda resultar en crecimiento   anormal del tejido de granulaci&oacute;n o en la formaci&oacute;n de una nueva estenosis o de   un tracto fistuloso.</p>     <p>Tres tipos diferentes de stents expandibles se han utilizado   para el tratamiento de las estenosis esof&aacute;gicas refractarias, tales como el stent   autoexpandible de pl&aacute;stico, los stents met&aacute;licos cubiertos autoexpandibles y   los stents biodegradables. Hasta la fecha, solo se ha publicado un solo estudio   que compar&oacute; la eficacia de estos tres tipos de stents. Canena (36) demostr&oacute; que   la colocaci&oacute;n temporal de un stent met&aacute;lico autoexpandible o un stent   biodegradable tiene una utilidad similar en el tratamiento de las estenosis   esof&aacute;gicas refractarias con resoluci&oacute;n de la disfagia a largo plazo, de un 40%   y un 30%, respectivamente. La colocaci&oacute;n de los stents de pl&aacute;stico   autoexpandibles estuvo asociada con el menor &eacute;xito cl&iacute;nico de los tres, de solo   un 10%. Dichos stents de pl&aacute;stico autoexpandibles tambi&eacute;n estuvieron asociados   con una incidencia mayor de migraci&oacute;n y reintervenci&oacute;n. La migraci&oacute;n con los stents   met&aacute;licos expandibles fue del 30% comparado con los stents biodegradables, del   20%. La implementaci&oacute;n de dilataci&oacute;n con bal&oacute;n del stent biodegradable despu&eacute;s   de la colocaci&oacute;n disminuy&oacute; la incidencia de migraci&oacute;n.</p>     <p>El dolor tor&aacute;cico fue la complicaci&oacute;n m&aacute;s frecuente que se   ha reportado en los diferentes estudios. La hiperplasia de tejido ocurre en   conjunto con la degradaci&oacute;n del stent. Casos de hiperplasia severa con recurrencia   de disfagia han sido reportados (29, 32-35). Para solucionar este problema, se   ha reportado tratamiento con arg&oacute;n plasma (29, 32) o dilataci&oacute;n con bal&oacute;n (35).   Otras complicaciones potenciales de los stents biodegradables son el colapso   del stent en el lumen esof&aacute;gico y la f&iacute;stula traqueoesof&aacute;gica (37).</p>     <p>Se puede concluir que despu&eacute;s de revisar las series   publicadas hasta la fecha, parece que un subgrupo de pacientes con este tipo de   estenosis esof&aacute;gica refractaria al tratamiento endosc&oacute;pico est&aacute; destinado a un   tratamiento prolongado con dilataciones, lo que incrementa el riesgo de   complicaciones, los costos inherentes al tratamiento y reduce   significativamente la calidad de vida. Este subgrupo de pacientes ser&iacute;an   candidatos al tratamiento con stents biodegradables. Los estudios que se han   publicado hasta la fecha tienen limitaciones en el dise&ntilde;o; sin embargo, han   demostrado que los stents biodegradables son efectivos, seguros y representan   una alternativa muy atractiva en este subgrupo de pacientes.</p>     <p><b>Intestino delgado y colon</b></p>     <p>Los stents biodegradables pueden ser una opci&oacute;n terap&eacute;utica   promisoria en pacientes con estenosis del intestino delgado y del colon. La   primera descripci&oacute;n de un stent biodegradable en esta ubicaci&oacute;n se le atribuye   al grupo checo de Rejchrt (22). Las estenosis posquir&uacute;rgicas, principalmente   despu&eacute;s de cirug&iacute;a de colon y recto, son las m&aacute;s frecuentes y ocurren entre el   1,5% y el 8% de los pacientes. Las estenosis tambi&eacute;n pueden ocurrir despu&eacute;s de   la resecci&oacute;n de c&aacute;ncer de colon (38-41) en casos de resecci&oacute;n de f&iacute;stulas   col&oacute;nicas (35) y tambi&eacute;n en casos de enfermedad de Crohn con estenosis (22,   42). La colocaci&oacute;n a nivel intestinal es posible y es relativamente simple   excepto en casos de estenosis proximales, cuando hay una deformidad o   angulaci&oacute;n marcada. El introductor tiene una longitud aproximada de 75 cm, lo   cual es una limitante. En la mayor&iacute;a de los casos, es dif&iacute;cil colocar un stent   a m&aacute;s de 30 cm del ano. Para esto, se ha sugerido el uso de un sobretubo (22).   La migraci&oacute;n del stent es una de las grandes limitantes y es la raz&oacute;n principal   de falla en la respuesta cl&iacute;nica. Se han utilizado diferentes t&eacute;cnicas para   evitar la migraci&oacute;n. Hasta la fecha no se ha documentado hiperplasia de la   mucosa en casos de estenosis intestinales tratadas con stents biodegradables   (<a href="#figura9">figura 9</a>).</p>     <p align="center"><img src="img/revistas/rcg/v30n2/v30n2a06f9.jpg" width="580" height="291"><a name="figura9"></a></p>     <p>Se puede decir que los stents biodegradables son una nueva   opci&oacute;n para el tratamiento de estenosis del intestino delgado y del colon   posquir&uacute;rgico y secundario a enfermedad de Crohn. El uso de este tipo de stents   disminuye la necesidad de repetir endoscopias y dilataciones. Consecuentemente   disminuye el riesgo de perforaciones y procedimientos quir&uacute;rgicos. La alta   incidencia de migraci&oacute;n temprana se puede solucionar con mejor&iacute;as en el dise&ntilde;o   del stent. Se necesitan m&aacute;s estudios para determinar la eficacia y seguridad de   estos stents a largo plazo.</p>     ]]></body>
<body><![CDATA[<p><b>Tracto biliar y pancre&aacute;tico</b></p>     <p>La endoscopia es el tratamiento de elecci&oacute;n para las   estenosis biliares benignas. El papel de los stents biodegradables en la   pr&aacute;ctica cl&iacute;nica no est&aacute; bien establecido y es una de las &aacute;reas de   investigaci&oacute;n actual en diferentes modelos animales (43, 44). Las causas de   estenosis biliares son m&uacute;ltiples pero las dos m&aacute;s comunes son las estenosis   posquir&uacute;rgicas y las estenosis secundarias a pancreatitis cr&oacute;nica (45). Los stents   disponibles actualmente en el mercado para los conductos biliares y el conducto   pancre&aacute;tico son de pl&aacute;stico o met&aacute;licos. Dichos stents tienen sus limitaciones   aun en los estudios animales (46). Laukkarinen (47, 48) public&oacute; diferentes   estudios con modelos animales en los que us&oacute; stents biodegradables en los   conductos biliares y en el conducto pancre&aacute;tico. Este grupo de autores ha   investigado la degradaci&oacute;n, permeabilidad y toxicidad de los stents   biodegradables hechos de &aacute;cido polil&aacute;ctico. Estos stents han sido usados en   cerdos y despu&eacute;s de 6 meses de colocados no se han observado cambios   histol&oacute;gicos o anat&oacute;micos.</p>     <p>Petrtyl (49) y Mauri (50) han publicado su experiencia con   el uso de stents biodegradables de polidioxanona colocados por v&iacute;a percut&aacute;nea   en el conducto biliar. En estos dos estudios se trataron 12 pacientes con   estenosis biliar posquir&uacute;rgica y se demostr&oacute; un buen &eacute;xito cl&iacute;nico a 2 a&ntilde;os de seguimiento.</p>     <p><b>CONCLUSIONES</b></p>     <p>Aunque no existen en el mercado nacional los stents   biodegradables, sus costos en el momento son prohibitivos. La experiencia   acumulada hasta la fecha en otras latitudes, en donde utiliz&oacute; el &uacute;nico stent   biodegradable de uso endosc&oacute;pico y hecho del pol&iacute;mero de polidioxanona, ha   demostrado resultados promisorios. La revisi&oacute;n de la literatura permite decir   que los stents biodegradables son una nueva opci&oacute;n para el tratamiento de   estenosis refractarias del es&oacute;fago, estenosis biliar, del intestino delgado y   del colon, como tambi&eacute;n estenosis secundarias a enfermedad de Crohn. El uso de   este tipo de stents disminuye la necesidad de repetir endoscopias y   dilataciones. Consecuentemente disminuye el riesgo de perforaciones y   procedimientos quir&uacute;rgicos. La alta incidencia de migraci&oacute;n temprana se puede   solucionar con mejor&iacute;as en el dise&ntilde;o del stent. Se necesitan m&aacute;s estudios para   determinar la eficacia y seguridad de estos stents a largo plazo. Se debe   mejorar la p&eacute;rdida de la fuerza radial con el tiempo debido a la degradaci&oacute;n.</p>     <p>Sin duda se necesitan estudios donde se pueda comparar el   uso de estos stents biodegradables versus stents expandibles totalmente   cubiertos. Los seguimientos de los estudios deben ser a largo plazo para   evaluar la remisi&oacute;n de los s&iacute;ntomas con el uso de estos stents. Tambi&eacute;n ser&iacute;a   de gran importancia evaluar el uso de estos stents biodegradables en pacientes   con c&aacute;ncer esof&aacute;gico o disfagia maligna antes de la quimioterapia o la   radioterapia. Por &uacute;ltimo, el stent ideal para las estenosis benignas deber&iacute;a   ser de di&aacute;metro amplio, alta expansi&oacute;n, alta flexibilidad, que mantenga la   integridad luminal, que no cause hiperplasia epitelial o da&ntilde;o del tejido y que   no se necesite repetir la endoscopia para la extracci&oacute;n del stent. Es muy   probable que los stents biodegradables sean el stent ideal para lograr estas   metas en un futuro.</p>     <p><b>REFERENCIAS</b></p>     <!-- ref --><p>1. Tringali A, Blero D, Boskoski I, et al. Difficult removal   of fully covered self expandable metal stents (SEMS) for benign biliary   strictures: The "SEMS in SEMS" technique. Dig Liver Dis. 2014;46(6):568-71.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000060&pid=S0120-9957201500020000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>2. Sharaiha RZ, Kim KJ, Singh VK, et al. Endoscopic   stenting for benign upper gastrointestinal strictures and leaks. Surg Endosc.   2014;28:178-84.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000062&pid=S0120-9957201500020000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>3. Almadi MA, Azzam N, Alharbi O, Mohammed   AH, Sadaf N, Aljebreen AM. Complications and survival in patients   undergoing colonic stenting for malignant obstruction. World J Gastroenterol.   2013;19:7138-45.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000064&pid=S0120-9957201500020000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>4. van Boeckel PG, Dua KS, Weusten BL, et al. Fully covered   self-expandable metal stents (SEMS), partially covered SEMS and self-expandable   plastic stents for the treatment of benign esophageal ruptures and anastomotic   leaks. BMC Gastroenterology. 2012;12:19.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000066&pid=S0120-9957201500020000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>5. Gutierrez-Salmean G, Pelaez-Luna M, Gonzalez-Galeote E,   Lozoya-Gonzalez D, Fuchs-Tarlovsky V, Farca-Belsaguy A. Outcomes of temporary   self-expanding plastic stents (SEPS) use for gastrointestinal leaks. A case   series. Rev Gastroenterol M&eacute;x. 2009;74:181-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000068&pid=S0120-9957201500020000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>6. Committee AT, Tokar JL, Banerjee S, et   al. Drug-eluting/biodegradable stents. Gastrointest Endosc.   2011;74:954-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000070&pid=S0120-9957201500020000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>7. Lorenzo-Zuniga V, Moreno-de-Vega V,   Marin I, Boix J. Biodegradable stents in gastrointestinal endoscopy. World J   Gastroenter. 2014;20:2212-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000072&pid=S0120-9957201500020000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>8. Guo Q, Knight PT, Mather PT. Tailored   drug release from biodegradable stent coatings based on hybrid polyurethanes. J Control Release. 2009;137:224-33.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-9957201500020000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>9. Hermawan H, Dube D, Mantovani D.   Degradable metallic biomaterials: design and development of Fe-Mn alloys for   stents. J Biomed Mater Res A. 2010;93:1-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-9957201500020000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>10. Saito Y, Tanaka T, Andoh A, et al. Usefulness of   biodegradable stents constructed of poly-l-lactic acid monofilaments in   patients with benign esophageal stenosis. World J Gastroenter. 2007;13:3977-80.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-9957201500020000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>11. Neamtu I, Chiriac AP, Diaconu A, Nita LE, Balan V,   Nistor MT. Current concepts on cardiovascular stent devices. Mini Rev Med Chem.   2014;14(6):505-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-9957201500020000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>12. Austin AS, Khan Z, Cole AT, Freeman JG. Placement of esophageal self-expanding metallic stents without   fluoroscopy. Gastrointest Endosc. 2001;54:357-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-9957201500020000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>13. Han Y, Jing Q, Xu B, et al. Safety and efficacy of   biodegradable polymer-coated sirolimus-eluting stents in «real-world» practice:   18-month clinical and 9-month angiographic outcomes. JACC. 2009;2:303-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-9957201500020000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>14. Onuma Y, Serruys P, den Heijer P, et al. MAHOROBA,   first-in-man study: 6-month results of a biodegradable polymer sustained   release tacrolimus-eluting stent in de novo coronary stenoses. Eur Heart J.   2009;30:1477-85.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-9957201500020000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>15. Wykrzykowska JJ, Onuma Y, Serruys PW. Advances in stent   drug delivery: the future is in bioabsorbable stents. Expert   Opin Drug Deliv. 2009;6:113-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0120-9957201500020000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>16. Basha J, Appasani S, Vaiphei K, Gupta   V, Singh K, Kochhar R. Biodegradable stents: truly biodegradable with good   tissue harmony. Endoscopy. 2013;45(Suppl 2):E116-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-9957201500020000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>17. Athanasiou KA, Niederauer GG, Agrawal   CM. Sterilization, toxicity, biocompatibility and clinical applications of   polylactic acid/polyglycolic acid copolymers. Biomaterials.   1996;17:93-102.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-9957201500020000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>18. Griffiths EA, Gregory CJ, Pursnani KG,   Ward JB, Stockwell RC. The use of biodegradable (SX-ELLA) oesophageal   stents to treat dysphagia due to benign and malignant oesophageal disease. Surg   Endosc. 2012;26:2367-75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0120-9957201500020000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>19. Kemppainen E, Talja M, Riihela M, Pohjonen T, Tormala P,   Alfthan O. A bioresorbable urethral stent. An experimental study. Urol Res.   1993;21:235-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0120-9957201500020000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>20. Goldin E, Fiorini A, Ratan Y, et al. A new biodegradable   and self-expandable stent for benign esophageal strictures. Gastrointest   Endosc. 1996;43:294.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0120-9957201500020000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>21. Fry SW, Fleischer DE. Management of a refractory benign   esophageal stricture with a new biodegradable stent. Gastrointest   Endosc. 1997;45:179-82.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0120-9957201500020000600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>22. Rejchrt S, Kopacova M, Brozik J, Bures   J. Biodegradable stents for the treatment of benign stenoses of the small and   large intestines. Endoscopy. 2011;43:911-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0120-9957201500020000600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>23. Parviainen M, Sand J, Harmoinen A, et al. A new   biodegradable stent for the pancreaticojejunal anastomosis after   pancreaticoduodenal resection: in vitro examination and pilot experiences in   humans. Pancreas. 2000;21:14-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0120-9957201500020000600023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>24. Tanaka T, Takahashi M, Nitta N, et al. Newly developed   biodegradable stents for benign gastrointestinal tract stenoses: a preliminary   clinical trial. Digestion. 2006;74:199-205.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0120-9957201500020000600024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>25. Rejchrt S, Kopacova M, Bartova J, Bures   J. Intestinal biodegradable stents. initial experience in the czech republic. Folia   Gastroenterol Hepatol. 2009;7:7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0120-9957201500020000600025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>26. Vandenplas Y, Hauser B, Devreker T,   Urbain D, Reynaert H. A biodegradable esophageal stent in the treatment of a   corrosive esophageal stenosis in a child. J Pediatr Gastroenterol Nutr.   2009;49:254-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0120-9957201500020000600026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>27. van Hooft JE, van Berge Henegouwen MI,   Rauws EA, Bergman JJ, Busch OR, Fockens P. Endoscopic treatment of benign   anastomotic esophagogastric strictures with a biodegradable stent. Gastrointest   Endosc. 2011;73:1043-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0120-9957201500020000600027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>28. Hirdes MM, Siersema PD, van Boeckel PG, Vleggaar FP. Single   and sequential biodegradable stent placement for refractory benign esophageal   strictures: a prospective follow-up study. Endoscopy. 2012;44:649-54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0120-9957201500020000600028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>29. Karakan T, Utku OG, Dorukoz O, et al. Biodegradable   stents for caustic esophageal strictures: a new therapeutic approach. Dis   Esophagus. 2013;26:319-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0120-9957201500020000600029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>30. Stivaros SM, Williams LR, Senger C,   Wilbraham L, Laasch HU. Woven polydioxanone biodegradable stents: a new   treatment option for benign and malignant oesophageal strictures. Eur Radiol.   2010;20:1069-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0120-9957201500020000600030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>31. Repici A, Vleggaar FP, Hassan C, et al. Efficacy and   safety of biodegradable stents for refractory benign esophageal strictures: the   BEST (Biodegradable Esophageal Stent) study. Gastrointest Endosc.   2010;72:927-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0120-9957201500020000600031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>32. Hair CS, Devonshire DA. Severe hyperplastic tissue   stenosis of a novel biodegradable esophageal stent and subsequent successful   management with high-pressure balloon dilation. Endoscopy. 2010;(42 Suppl   2):E132-3.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0120-9957201500020000600032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>33. Orive-Calzada A, Alvarez-Rubio M, Romero-Izquierdo S, et   al. Severe epithelial hyperplasia as a complication of a novel biodegradable   stent. Endoscopy. 2009;41(Suppl 2):E137-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0120-9957201500020000600033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>34. Fischer A, Bausch D, Baier P, Braun A,   Richter-Schrag H. Risk of biodegradable stent-induced hypergranulation causing   re-stenosis of a gastric conduit after esophageal resection. Endoscopy.   2012;44(Suppl 2):E125-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0120-9957201500020000600034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>35. Dumoulin FL, Plassmann D. Tissue   hyperplasia following placement of a biodegradable stent for a refractory   esophageal stricture: treatment with argon plasma coagulation. Endoscopy.   2012;44(Suppl 2):E356-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0120-9957201500020000600035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>36. Canena JM, Liberato MJ, Rio-Tinto RA, et al. A   comparison of the temporary placement of 3 different self-expanding stents for   the treatment of refractory benign esophageal strictures: a prospective   multicentre study. BMC. 2012;12:70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0120-9957201500020000600036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>37. Jung GE, Sauer P, Schaible A.   Tracheoesophageal fistula following implantation of a biodegradable stent for a   refractory benign esophageal stricture. Endoscopy. 2010;42(Suppl   2):E338-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0120-9957201500020000600037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>38. Repici A, Pagano N, Rando G, et al. A retrospective   analysis of early and late outcome of biodegradable stent placement in the management   of refractory anastomotic colorectal strictures. Surg Endosc. 2013;27:2487-91.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0120-9957201500020000600038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>39. Perez Roldan F, Gonzalez Carro P, Villafanez Garcia MC,   et al. Usefulness of biodegradable polydioxanone stents in the treatment of   postsurgical colorectal strictures and fistulas. Endoscopy. 2012;44:297-300.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0120-9957201500020000600039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>40. Toth E, Nielsen J, Nemeth A, et al. Treatment of a   benign colorectal anastomotic stricture with a biodegradable stent. Endoscopy.   2011;43(Suppl 2):E252-3.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0120-9957201500020000600040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>41. Janik V, Horak L, Hnanicek J, Malek J,   Laasch HU. Biodegradable polydioxanone stents: a new option for   therapy-resistant anastomotic strictures of the colon. Eur Radiol.   2011;21:1956-61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0120-9957201500020000600041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>42. Rodrigues C, Oliveira A, Santos L,   Pires E, Deus J. Biodegradable stent for the treatment of a colonic stricture   in Crohn’s disease. World J Gastrointest Endosc. 2013;5:265-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0120-9957201500020000600042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>43. Ginsberg G, Cope C, Shah J, et al. In   vivo evaluation of a new bioabsorbable self-expanding biliary stent.   Gastrointest Endosc. 2003;58:777-84.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0120-9957201500020000600043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>44. Meng B, Wang J, Zhu N, Meng QY, Cui FZ, Xu YX. Study of   biodegradable and self-expandable PLLA helical biliary stent in vivo and in   vitro. J Mater Sci Mater Med. 2006;17:611-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0120-9957201500020000600044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>45. Kaffes AJ, Liu K. Fully covered   self-expandable metal stents for treatment of benign biliary strictures. Gastrointest   Endosc. 2013;78:13-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0120-9957201500020000600045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>46. Itoi T, Kasuya K, Abe Y, Isayama H.   Endoscopic placement of a new short-term biodegradable pancreatic and biliary   stent in an animal model: a preliminary feasibility study (with videos). J   Hepatobiliary Pancreat Sci. 2011;18:463-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0120-9957201500020000600046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>47. Lamsa T, Jin H, Mikkonen J, Laukkarinen   J, Sand J, Nordback I. Biocompatibility of a new bioabsorbable radiopaque stent   material (BaSO4 containing poly-L,D-lactide) in the rat pancreas. Pancreatology.   2006;6:301-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0120-9957201500020000600047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>48. Laukkarinen JM, Sand JA, Chow P, et al. A novel biodegradable biliary stent in the normal duct hepaticojejunal   anastomosis: an 18-month follow-up in a large animal model. J Gastrointest   Surgery. 2007;11:750-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S0120-9957201500020000600048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>49. Petrtyl J, Bruha R, Horak L, Zadorova Z, Dosedel J,   Laasch HU. Management of benign intrahepatic bile duct strictures: initial   experience with polydioxanone biodegradable stents. Endoscopy. 2010;42(Suppl   2):E89-90.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S0120-9957201500020000600049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>50. Mauri G, Michelozzi C, Melchiorre F, et   al. Biodegradable biliary stent implantation in the treatment of benign   bilioplastic-refractory biliary strictures: preliminary experience. Eur Radiol.   2013;23:3304-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S0120-9957201500020000600050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p></FONT>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tringali]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Blero]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Boskoski]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Difficult removal of fully covered self expandable metal stents (SEMS) for benign biliary strictures: The “SEMS in SEMS” technique]]></article-title>
<source><![CDATA[Dig Liver Dis]]></source>
<year>2014</year>
<volume>46</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>568-71</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sharaiha]]></surname>
<given-names><![CDATA[RZ]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[VK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Endoscopic stenting for benign upper gastrointestinal strictures and leaks]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2014</year>
<volume>28</volume>
<page-range>178-84</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Almadi]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Azzam]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Alharbi]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Mohammed]]></surname>
<given-names><![CDATA[AH]]></given-names>
</name>
<name>
<surname><![CDATA[Sadaf]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Aljebreen]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications and survival in patients undergoing colonic stenting for malignant obstruction]]></article-title>
<source><![CDATA[World J Gastroenterol]]></source>
<year>2013</year>
<volume>19</volume>
<page-range>7138-45</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Boeckel]]></surname>
<given-names><![CDATA[PG]]></given-names>
</name>
<name>
<surname><![CDATA[Dua]]></surname>
<given-names><![CDATA[KS]]></given-names>
</name>
<name>
<surname><![CDATA[Weusten]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks]]></article-title>
<source><![CDATA[BMC Gastroenterology]]></source>
<year>2012</year>
<volume>12</volume>
<numero>19</numero>
<issue>19</issue>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gutierrez-Salmean]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Pelaez-Luna]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzalez-Galeote]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Lozoya-Gonzalez]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Fuchs-Tarlovsky]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Farca-Belsaguy]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Outcomes of temporary self-expanding plastic stents (SEPS) use for gastrointestinal leaks]]></article-title>
<source><![CDATA[Rev Gastroenterol Méx]]></source>
<year>2009</year>
<volume>74</volume>
<page-range>181-6</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Committee]]></surname>
<given-names><![CDATA[AT]]></given-names>
</name>
<name>
<surname><![CDATA[Tokar]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Banerjee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Drug-eluting/biodegradable stents]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2011</year>
<volume>74</volume>
<page-range>954-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lorenzo-Zuniga]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno-de-Vega]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Marin]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Boix]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable stents in gastrointestinal endoscopy]]></article-title>
<source><![CDATA[World J Gastroenter]]></source>
<year>2014</year>
<volume>20</volume>
<page-range>2212-7</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guo]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Knight]]></surname>
<given-names><![CDATA[PT]]></given-names>
</name>
<name>
<surname><![CDATA[Mather]]></surname>
<given-names><![CDATA[PT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tailored drug release from biodegradable stent coatings based on hybrid polyurethanes]]></article-title>
<source><![CDATA[J Control Release]]></source>
<year>2009</year>
<volume>137</volume>
<page-range>224-33</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hermawan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Dube]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mantovani]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Degradable metallic biomaterials: design and development of Fe-Mn alloys for stents]]></article-title>
<source><![CDATA[J Biomed Mater Res A]]></source>
<year>2010</year>
<volume>93</volume>
<page-range>1-11</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saito]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Andoh]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Usefulness of biodegradable stents constructed of poly-l-lactic acid monofilaments in patients with benign esophageal stenosis]]></article-title>
<source><![CDATA[World J Gastroenter]]></source>
<year>2007</year>
<volume>13</volume>
<page-range>3977-80</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neamtu]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Chiriac]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Diaconu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Nita]]></surname>
<given-names><![CDATA[LE]]></given-names>
</name>
<name>
<surname><![CDATA[Balan]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nistor]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Current concepts on cardiovascular stent devices]]></article-title>
<source><![CDATA[Mini Rev Med Chem]]></source>
<year>2014</year>
<volume>14</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>505-36</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Austin]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Cole]]></surname>
<given-names><![CDATA[AT]]></given-names>
</name>
<name>
<surname><![CDATA[Freeman]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Placement of esophageal self-expanding metallic stents without fluoroscopy]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2001</year>
<volume>54</volume>
<page-range>357-9</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Jing]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Safety and efficacy of biodegradable polymer-coated sirolimus-eluting stents in «real-world» practice: 18-month clinical and 9-month angiographic outcomes]]></article-title>
<source><![CDATA[JACC]]></source>
<year>2009</year>
<volume>2</volume>
<page-range>303-9</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Onuma]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Serruys]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[den Heijer]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[MAHOROBA, first-in-man study: 6-month results of a biodegradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses]]></article-title>
<source><![CDATA[Eur Heart J]]></source>
<year>2009</year>
<volume>30</volume>
<page-range>1477-85</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wykrzykowska]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Onuma]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Serruys]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advances in stent drug delivery: the future is in bioabsorbable stents]]></article-title>
<source><![CDATA[Expert Opin Drug Deliv]]></source>
<year>2009</year>
<volume>6</volume>
<page-range>113-26</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Basha]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Appasani]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Vaiphei]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Kochhar]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable stents: truly biodegradable with good tissue harmony]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2013</year>
<volume>45</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E116-7</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Athanasiou]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Niederauer]]></surname>
<given-names><![CDATA[GG]]></given-names>
</name>
<name>
<surname><![CDATA[Agrawal]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1996</year>
<volume>17</volume>
<page-range>93-102</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Griffiths]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Gregory]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Pursnani]]></surname>
<given-names><![CDATA[KG]]></given-names>
</name>
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Stockwell]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of biodegradable (SX-ELLA) oesophageal stents to treat dysphagia due to benign and malignant oesophageal disease]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2012</year>
<volume>26</volume>
<page-range>2367-75</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kemppainen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Talja]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Riihela]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Pohjonen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Tormala]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Alfthan]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A bioresorbable urethral stent: An experimental study]]></article-title>
<source><![CDATA[Urol Res]]></source>
<year>1993</year>
<volume>21</volume>
<page-range>235-8</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Fiorini]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ratan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new biodegradable and self-expandable stent for benign esophageal strictures]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>1996</year>
<volume>43</volume>
<page-range>294</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fry]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Fleischer]]></surname>
<given-names><![CDATA[DE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Management of a refractory benign esophageal stricture with a new biodegradable stent]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>1997</year>
<volume>45</volume>
<page-range>179-82</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rejchrt]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kopacova]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Brozik]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bures]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable stents for the treatment of benign stenoses of the small and large intestines]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2011</year>
<volume>43</volume>
<page-range>911-7</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Parviainen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sand]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Harmoinen]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new biodegradable stent for the pancreaticojejunal anastomosis after pancreaticoduodenal resection: in vitro examination and pilot experiences in humans]]></article-title>
<source><![CDATA[Pancreas]]></source>
<year>2000</year>
<volume>21</volume>
<page-range>14-21</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Takahashi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Nitta]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Newly developed biodegradable stents for benign gastrointestinal tract stenoses: a preliminary clinical trial]]></article-title>
<source><![CDATA[Digestion]]></source>
<year>2006</year>
<volume>74</volume>
<page-range>199-205</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rejchrt]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kopacova]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bartova]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bures]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intestinal biodegradable stents: initial experience in the czech republic]]></article-title>
<source><![CDATA[Folia Gastroenterol Hepatol]]></source>
<year>2009</year>
<volume>7</volume>
<numero>7</numero>
<issue>7</issue>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vandenplas]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hauser]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Devreker]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Urbain]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Reynaert]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A biodegradable esophageal stent in the treatment of a corrosive esophageal stenosis in a child]]></article-title>
<source><![CDATA[J Pediatr Gastroenterol Nutr]]></source>
<year>2009</year>
<volume>49</volume>
<page-range>254-7</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Hooft]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[van Berge Henegouwen]]></surname>
<given-names><![CDATA[MI]]></given-names>
</name>
<name>
<surname><![CDATA[Rauws]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Bergman]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Busch]]></surname>
<given-names><![CDATA[OR]]></given-names>
</name>
<name>
<surname><![CDATA[Fockens]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Endoscopic treatment of benign anastomotic esophagogastric strictures with a biodegradable stent]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2011</year>
<volume>73</volume>
<page-range>1043-7</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hirdes]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Siersema]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[van Boeckel]]></surname>
<given-names><![CDATA[PG]]></given-names>
</name>
<name>
<surname><![CDATA[Vleggaar]]></surname>
<given-names><![CDATA[FP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Single and sequential biodegradable stent placement for refractory benign esophageal strictures]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2012</year>
<volume>44</volume>
<page-range>649-54</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karakan]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Utku]]></surname>
<given-names><![CDATA[OG]]></given-names>
</name>
<name>
<surname><![CDATA[Dorukoz]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable stents for caustic esophageal strictures]]></article-title>
<source><![CDATA[Dis Esophagus]]></source>
<year>2013</year>
<volume>26</volume>
<page-range>319-22</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stivaros]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[LR]]></given-names>
</name>
<name>
<surname><![CDATA[Senger]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Wilbraham]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Laasch]]></surname>
<given-names><![CDATA[HU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Woven polydioxanone biodegradable stents: a new treatment option for benign and malignant oesophageal strictures]]></article-title>
<source><![CDATA[Eur Radiol]]></source>
<year>2010</year>
<volume>20</volume>
<page-range>1069-72</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Repici]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vleggaar]]></surname>
<given-names><![CDATA[FP]]></given-names>
</name>
<name>
<surname><![CDATA[Hassan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Efficacy and safety of biodegradable stents for refractory benign esophageal strictures: the BEST (Biodegradable Esophageal Stent) study]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2010</year>
<volume>72</volume>
<page-range>927-34</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hair]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Devonshire]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Severe hyperplastic tissue stenosis of a novel biodegradable esophageal stent and subsequent successful management with high-pressure balloon dilation]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2010</year>
<volume>42</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E132-3</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orive-Calzada]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Alvarez-Rubio]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Romero-Izquierdo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Severe epithelial hyperplasia as a complication of a novel biodegradable stent]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2009</year>
<volume>41</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E137-8</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fischer]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bausch]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Baier]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Braun]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Richter-Schrag]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Risk of biodegradable stent-induced hypergranulation causing re-stenosis of a gastric conduit after esophageal resection]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2012</year>
<volume>44</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dumoulin]]></surname>
<given-names><![CDATA[FL]]></given-names>
</name>
<name>
<surname><![CDATA[Plassmann]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tissue hyperplasia following placement of a biodegradable stent for a refractory esophageal stricture: treatment with argon plasma coagulation]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2012</year>
<volume>44</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E356-7</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Canena]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Liberato]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Rio-Tinto]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study]]></article-title>
<source><![CDATA[BMC]]></source>
<year>2012</year>
<volume>12</volume>
<page-range>70</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jung]]></surname>
<given-names><![CDATA[GE]]></given-names>
</name>
<name>
<surname><![CDATA[Sauer]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Schaible]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tracheoesophageal fistula following implantation of a biodegradable stent for a refractory benign esophageal stricture]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2010</year>
<volume>42</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E338-9</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Repici]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pagano]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Rando]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A retrospective analysis of early and late outcome of biodegradable stent placement in the management of refractory anastomotic colorectal strictures]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2013</year>
<volume>27</volume>
<page-range>2487-9</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Perez Roldan]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzalez Carro]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Villafanez Garcia]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Usefulness of biodegradable polydioxanone stents in the treatment of postsurgical colorectal strictures and fistulas]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2012</year>
<volume>44</volume>
<page-range>297-300</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Toth]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Nielsen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nemeth]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of a benign colorectal anastomotic stricture with a biodegradable stent]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2011</year>
<volume>43</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E252-3</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Janik]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Horak]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hnanicek]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Malek]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Laasch]]></surname>
<given-names><![CDATA[HU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable polydioxanone stents: a new option for therapy-resistant anastomotic strictures of the colon]]></article-title>
<source><![CDATA[Eur Radiol]]></source>
<year>2011</year>
<volume>21</volume>
<page-range>1956-61</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodrigues]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Pires]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Deus]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable stent for the treatment of a colonic stricture in Crohn's disease]]></article-title>
<source><![CDATA[World J Gastrointest Endosc]]></source>
<year>2013</year>
<volume>5</volume>
<page-range>265-9</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ginsberg]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cope]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo evaluation of a new bioabsorbable self-expanding biliary stent]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2003</year>
<volume>58</volume>
<page-range>777-84</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Meng]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Meng]]></surname>
<given-names><![CDATA[QY]]></given-names>
</name>
<name>
<surname><![CDATA[Cui]]></surname>
<given-names><![CDATA[FZ]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[YX]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study of biodegradable and self-expandable PLLA helical biliary stent in vivo and in vitro]]></article-title>
<source><![CDATA[J Mater Sci Mater Med]]></source>
<year>2006</year>
<volume>17</volume>
<page-range>611-7</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaffes]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fully covered self-expandable metal stents for treatment of benign biliary strictures]]></article-title>
<source><![CDATA[Gastrointest Endosc]]></source>
<year>2013</year>
<volume>78</volume>
<page-range>13-21</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Itoi]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kasuya]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Abe]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Isayama]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Endoscopic placement of a new short-term biodegradable pancreatic and biliary stent in an animal model: a preliminary feasibility study (with videos)]]></article-title>
<source><![CDATA[J Hepatobiliary Pancreat Sci]]></source>
<year>2011</year>
<volume>18</volume>
<page-range>463-7</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lamsa]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Jin]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Mikkonen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Laukkarinen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sand]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nordback]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biocompatibility of a new bioabsorbable radiopaque stent material (BaSO4 containing poly-L,D-lactide) in the rat pancreas]]></article-title>
<source><![CDATA[Pancreatology]]></source>
<year>2006</year>
<volume>6</volume>
<page-range>301-5</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Laukkarinen]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Sand]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Chow]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A novel biodegradable biliary stent in the normal duct hepaticojejunal anastomosis: an 18-month follow-up in a large animal model]]></article-title>
<source><![CDATA[J Gastrointest Surgery]]></source>
<year>2007</year>
<volume>11</volume>
<page-range>750-7</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Petrtyl]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bruha]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Horak]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Zadorova]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Dosedel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Laasch]]></surname>
<given-names><![CDATA[HU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Management of benign intrahepatic bile duct strictures: initial experience with polydioxanone biodegradable stents]]></article-title>
<source><![CDATA[Endoscopy]]></source>
<year>2010</year>
<volume>42</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>E89-90</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mauri]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Michelozzi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Melchiorre]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biodegradable biliary stent implantation in the treatment of benign bilioplastic-refractory biliary strictures: preliminary experience]]></article-title>
<source><![CDATA[Eur Radiol]]></source>
<year>2013</year>
<volume>23</volume>
<page-range>3304-10</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
