<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2009000100007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Evaluación de la fricción en arcos ortodóncicos de acero inoxidable con y sin recubrimiento vítreo aplicado por el método Sol-Gel]]></article-title>
<article-title xml:lang="en"><![CDATA[Friction evaluation in stainless steel arches with and withouth glass coating using the Sol-Gel method]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valencia Álvarez]]></surname>
<given-names><![CDATA[José A]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Montoya Goez]]></surname>
<given-names><![CDATA[Yesid]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Peláez Vargas]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Jaramillo Vallejo]]></surname>
<given-names><![CDATA[Pedro M]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[Claudia García]]></given-names>
</name>
<xref ref-type="aff" rid="A05"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad CES Escuela de Ingeniería de Antioquia ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Nacional de Colombia-Sede Medellín Escuela de Física ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología Grupo POPCAD]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A05">
<institution><![CDATA[,Universidad Nacional de Colombia, Sede Medellín Escuela de Física Grupo de Cerámicos y Vítreos]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2009</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2009</year>
</pub-date>
<volume>20</volume>
<numero>2</numero>
<fpage>161</fpage>
<lpage>170</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2009000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2009000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2009000100007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: el propósito de este estudio in vitro fue comparar la fuerza de fricción estática y dinámica generada entre brackets y alambres de acero inoxidable con y sin recubrimiento vítreo aplicado por el método Sol-Gel. MÉTODOS: en todas las pruebas de fricción fueron utilizados brackets (0,018 x 0,025&rdquo;), alambres de acero inoxidable (0,016 x 0,016&rdquo;) y ligaduras elásticas. Se realizó una caracterización con microscopia óptica y microscopia electrónica de barrido (SEM). La fuerza friccional fue evaluada utilizando una máquina de pruebas Testresources® en medio seco. RESULTADOS: los resultados mostraron que el grupo de alambres de acero inoxidable sin modificación (grupo control) presentaron los valores más bajos de fuerza de fricción estática, seguido del grupo de alambres recubiertos por el método Sol-Gel (grupo Sol-Gel) y el grupo de alambres con tratamiento térmico (grupo térmico). Para la fricción dinámica, el grupo Sol-Gel mostró los valores más bajos, seguido del grupo control y el grupo térmico. CONCLUSIÓN: los recubrimientos evaluados no mostraron mejor comportamiento friccional sobre brackets de acero inoxidable cuando son comparados con el grupo control.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: the aim of this in vitro study was to compare the static and dynamic frictional force generated between surfaces of metallic brackets and glass coated applied by the Sol-Gel method, and non coated wires. METHODS: metallic brackets (0,018 x 0,025&rdquo;), stainless steel wires (0,016 x 0,016&rdquo;) and elastic ligatures were used in all frictional tests. All components were characterized using SE M and optical microscopy. The frictional force was evaluated using a machine of tests Testresources® in dry environment. RESULTS: the results showed that the stainless steel wires without modification (control group) showed the lowest values of static friction force followed by the stainless steel wires group coated by Sol-Gel method and the wires group with thermic treatment (thermic group). For dynamic friction force, the Sol-Gel group showed the smallest values, followed by the control group and the thermal group. CONCLUSIONS: the evaluated coating did not show a better frictional performance applied on stainless steel brackets in comparison with the control group.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[fricción]]></kwd>
<kwd lng="es"><![CDATA[brackets]]></kwd>
<kwd lng="es"><![CDATA[alambres de acero]]></kwd>
<kwd lng="es"><![CDATA[recubrimientos]]></kwd>
<kwd lng="es"><![CDATA[Sol-Gel]]></kwd>
<kwd lng="en"><![CDATA[Friction]]></kwd>
<kwd lng="en"><![CDATA[brackets]]></kwd>
<kwd lng="en"><![CDATA[steel wires]]></kwd>
<kwd lng="en"><![CDATA[coatings]]></kwd>
<kwd lng="en"><![CDATA[Sol-Gel]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Evaluaci&oacute;n de la fricci&oacute;n en arcos ortod&oacute;ncicos de acero inoxidable con y sin recubrimiento v&iacute;treo aplicado por el m&eacute;todo Sol-Gel<sup>1</sup></b></font></p>          <p>&nbsp;</p>           <p align="center"><font size="3" face="Verdana"><b>Friction evaluation in stainless steel arches with and withouth glass coating using the Sol-Gel method</b></font></p>           <p>&nbsp;</p>          <p>&nbsp;</p>           <p><b>Jos&eacute; A. Valencia &Aacute;lvarez<sup>2</sup>; Yesid Montoya Goez<sup>3</sup>; Alejandro Pel&aacute;ez Vargas<sup>4</sup>; Pedro M. Jaramillo Vallejo<sup>5</sup>; Claudia Garc&iacute;a Garc&iacute;a<sup>6</sup></b></p>      <p><sup>1</sup> Investigaci&oacute;n realizada como requisito parcial para optar al t&iacute;tulo de especialista en Odontolog&iacute;a Integral del Adolescente y Ortodoncia. Proyecto Interinstitucional desarrollado por el Grupo POPCAD de la Universidad de Antioquia, el Grupo de Cer&aacute;micos y V&iacute;treos de la Universidad Nacional de Colombia, Sede Medell&iacute;n, el Grupo de Investigaci&oacute;n CES-LPH de la Universidad CES y la Facultad de Ingenier&iacute;a Biom&eacute;dica de la Escuela de Ingenier&iacute;a de Antioquia-Universidad CES</a>    ]]></body>
<body><![CDATA[<br>  <sup>2</sup> Estudiante, posgrado Odontolog&iacute;a Integral del Adolescente y Ortodoncia, Facultad de Odontolog&iacute;a. Universidad de Antioquia, Medell&iacute;n, Colombia. <a href="mailto: orthos@epm.net.co">orthos@epm.net.co</a>    <br>      <sup>3</sup> Ingeniero civil, M.Sc., profesor de Ingenier&iacute;a Biom&eacute;dica. Escuela de Ingenier&iacute;a de Antioquia-Universidad CES. Medell&iacute;n, Colombia. <a href="mailto: pfyemon@eia.edu.co">pfyemon@eia.edu.co</a>    <br>  <sup>4</sup> Odont&oacute;logo, BMES, M.Sc. profesor asistente. Grupo de Investigaci&oacute;n CES-LPH. Facultad de Odontolog&iacute;a, Universidad CES. Grupo de Cer&aacute;micos y V&iacute;treos. Escuela de F&iacute;sica. Universidad Nacional de Colombia-Sede Medell&iacute;n. <a href="mailto: alejandropelaezvargas@yahoo.com">alejandropelaezvargas@yahoo.com</a>    <br>  <sup>5</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adolescente. Grupo POPCAD, profesor asociado. Facultad de Odontolog&iacute;a. Universidad de Antioquia. Medell&iacute;n, Colombia. <a href="mailto: orthoclinic@une.net.co">orthoclinic@une.net.co</a>    <br>  <sup>6</sup> Ingeniera Ge&oacute;loga. Ph.D. profesor asociado. Grupo de Cer&aacute;micos y V&iacute;treos. Escuela de F&iacute;sica. Universidad Nacional de Colombia, Sede Medell&iacute;n. <a href="mailto: cpgarcia@unalmed.edu.co">cpgarcia@unalmed.edu.co</a></p> </p>      <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> el prop&oacute;sito de este estudio in vitro fue comparar la fuerza de fricci&oacute;n est&aacute;tica y din&aacute;mica generada entre brackets y alambres de acero inoxidable con y sin recubrimiento v&iacute;treo aplicado por el m&eacute;todo Sol-Gel.    <br>  <b>M&Eacute;TODOS:</b> en todas las pruebas de fricci&oacute;n fueron utilizados brackets (0,018 x 0,025&rdquo;), alambres de acero inoxidable (0,016 x 0,016&rdquo;) y ligaduras el&aacute;sticas. Se realiz&oacute; una caracterizaci&oacute;n con microscopia &oacute;ptica y microscopia electr&oacute;nica de barrido (SEM). La fuerza friccional fue evaluada utilizando una m&aacute;quina de pruebas Testresources<sup>&reg;</sup> en medio seco.    ]]></body>
<body><![CDATA[<br>  <b>RESULTADOS:</b> los resultados mostraron que el grupo de alambres de acero inoxidable sin modificaci&oacute;n (grupo control) presentaron los valores m&aacute;s bajos de fuerza de fricci&oacute;n est&aacute;tica, seguido del grupo de alambres recubiertos por el m&eacute;todo Sol-Gel (grupo Sol-Gel) y el grupo de alambres con tratamiento t&eacute;rmico (grupo t&eacute;rmico). Para la fricci&oacute;n din&aacute;mica, el grupo Sol-Gel mostr&oacute; los valores m&aacute;s bajos, seguido del grupo control y el grupo t&eacute;rmico.    <br>   <b>CONCLUSI&Oacute;N:</b> los recubrimientos evaluados no mostraron mejor comportamiento friccional sobre brackets de acero inoxidable cuando son comparados con el grupo control.</p>      <p><b>Palabras clave:</b> fricci&oacute;n, brackets, alambres de acero, recubrimientos, Sol-Gel.</p>   <hr noshade>           <p><b>ABSTRACT</b></p>           <p><b>INTRODUCTION:</b> the aim of this in vitro study was to compare the static and dynamic frictional force generated between surfaces of metallic brackets and glass coated applied by the Sol-Gel method, and non coated wires.    <br>  <b>METHODS:</b> metallic brackets (0,018 x 0,025&rdquo;), stainless steel wires (0,016 x 0,016&rdquo;) and elastic ligatures were used in all frictional tests. All components were characterized using SE M and optical microscopy. The frictional force was evaluated using a machine of tests Testresources<sup>&reg;</sup> in dry environment.    <br>  <b>RESULTS:</b> the results showed that the stainless steel wires without modification (control group) showed the lowest values of static friction force followed by the stainless steel wires group coated by Sol-Gel method and the wires group with thermic treatment (thermic group). For dynamic friction force, the Sol-Gel group showed the smallest values, followed by the control group and the thermal group.    <br>  <b>CONCLUSIONS:</b> the evaluated coating did not show a better frictional performance applied on stainless steel brackets in comparison with the control group.</p>      <p><b>Key words:</b>Friction, brackets, steel wires, coatings, Sol-Gel.</p>  <hr noshade>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      <p>La t&eacute;cnica de deslizamiento en ortodoncia es afectada por variables que influyen en el comportamiento de la dupla alambre-bracket como la composici&oacute;n de los arcos<sup>1, 2</sup> y los brackets,<sup>3-5</sup> el ancho y el tama&ntilde;o de la ranura del brackets,<sup>6</sup> la forma y el espesor de los arcos,<sup>7</sup> angulaciones del arco<sup>8, 9</sup>, el tipo de ligado<sup>10</sup> y el material de la ligadura,<sup>11</sup> medio h&uacute;medo o seco,<sup>12</sup> materiales esterilizados.</p>      <p>Estudios previos han evaluado el &aacute;ngulo de contacto cr&iacute;tico entre la ranura y el bracket, donde se dan los fen&oacute;menos mec&aacute;nicos conocidos como binding y notching, que contribuyen a la resistencia al deslizamiento en ortodoncia. Se ha mostrado que a mayor &aacute;ngulo de contacto de binding mayor es la fricci&oacute;n y a mayor &aacute;ngulo existente entre el eje del alambre y el eje de la ranura, mayor es la fuerza de fricci&oacute;n.<sup>13-15</sup></p>      <p>Actualmente se busca disminuir la resistencia al deslizamiento, y una de las alternativas es modificar la topograf&iacute;a superficial de brackets, alambres o ambos. Teniendo en cuenta que la fricci&oacute;n depende del coeficiente de fricci&oacute;n de las superficies puestas en contacto, y es mayor cuando uno o ambos de los materiales presentan mayor rugosidad en su topograf&iacute;a superficial,<sup>16</sup> cualquier tratamiento que afecte la superficie de arcos y brackets de acero inoxidable pueden incidir sobre la fuerza de fricci&oacute;n del sistema. Entre los tratamientos superficiales reportados en la literatura se cuentan la implantaci&oacute;n de iones dentro del sustrato, la carburizaci&oacute;n, y la nitruraci&oacute;n.<sup>17</sup> Otra alternativa es el revestimiento de la superficie, que puede llevarse a cabo por varios m&eacute;todos incluyendo el recubrimiento con una capa met&aacute;lica, el dep&oacute;sito de vapores qu&iacute;micos (CVD), los recubrimientos asistidos por plasma (PVD), la deposici&oacute;n de pol&iacute;meros, los revestimientos con carbono y los recubrimientos inorg&aacute;nicos no met&aacute;licos.<sup>18</sup></p>      <p>Los recubrimientos inorg&aacute;nicos no met&aacute;licos se pueden depositar por m&eacute;todos mim&eacute;ticos, electroformado, inmersi&oacute;n en soluciones, suspensiones o geles (m&eacute;todo Sol-Gel) y la deposici&oacute;n por plasma (PVD)<sup>18</sup>. Los recubrimientos realizados por el m&eacute;todo Sol-Gel tienen la ventaja de requerir menores temperaturas para su aplicaci&oacute;n y alcanzan buena adherencia a la superficie del sustrato. Adicionalmente, sirven de barrera contra la humedad, pueden aumentar la resistencia a la fractura, la resistencia al desgaste, sirven como aislantes t&eacute;rmicos y el&eacute;ctricos, pueden aumentar la resistencia a la corrosi&oacute;n y no presentan efectos genot&oacute;xicos.<sup>19-23</sup></p>      <p>El prop&oacute;sito de este estudio in vitro fue comparar la fuerza de fricci&oacute;n est&aacute;tica y din&aacute;mica generada entre brackets de acero inoxidable y alambres de acero inoxidable con y sin recubrimiento v&iacute;treo aplicado por el m&eacute;todo Sol-Gel.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>MATERIALES Y M&Eacute;TODOS</b></font></p>      <p>Para este estudio de tipo experimental, se utilizaron alambres (n = 60) de acero inoxidable AISI 303 de uso ortod&oacute;ncico (0,016 x 0,016&rdquo;, Ormco<sup>&reg;</sup>) con 10 cm de longitud. Los alambres se dividieron en: Un grupo Sol-Gel que incluy&oacute; alambres recubiertos con una capa v&iacute;trea por inmersi&oacute;n-extracci&oacute;n. Un grupo control que incluy&oacute; alambres sin modificaci&oacute;n. Y un grupo t&eacute;rmico donde alambres desnudos fueron sometidos al mismo tratamiento t&eacute;rmico necesario para la sinterizaci&oacute;n del recubrimiento v&iacute;treo.</p>      ]]></body>
<body><![CDATA[<p>Se utilizaron seis brackets est&aacute;ndar para caninos superiores de acero inoxidable AISI 303 con ranura (0,018 x 0,025&rdquo;) de acero inoxidable (Ormco Diamond&rdquo;). Para evaluar la resistencia a la fricci&oacute;n entre los brackets y los tres grupos de alambres, se ubic&oacute; un bracket nuevo cada veinte pruebas de forma aleatoria. Los alambres y los brackets fueron ligados con anillos el&aacute;sticos (poliuretano-libre de l&aacute;tex) de color negro (di&aacute;metro interno 0,045&rdquo; y externo 0,115&rdquo;, American Orthodontics<sup>&reg;</sup>).</p>      <p>El m&oacute;dulo de elasticidad de las ligaduras fue determinado con una m&aacute;quina de ensayos universales (Test resources &ndash; 650R<sup>&reg;</sup>, celda de carga de 10 lb &plusmn; 0,00043 lb), acoplado a un software para adquisici&oacute;n y an&aacute;lisis de datos (MtestWR).</p>      <p>Se realiz&oacute; un an&aacute;lisis de topograf&iacute;a superficial de los brackets, alambres y ligaduras por microscopia &oacute;ptica (Olympus PME 3-ADL<sup>&reg;</sup> con un analizador de imagen Leyca Q5001W) y microscopia electr&oacute;nica de barrido (SEM, JEOL JSM&ndash;5910LV<sup>&reg;</sup>) a 15 kV a distancia de trabajo de 13 mm.</p>      <p><b>Recubrimiento v&iacute;treo</b></p>      <p>Los alambres utilizados como sustrato para aplicar los recubrimientos (grupo Sol-Gel) fueron lavados por un m&eacute;todo est&aacute;ndar y sumergidos en un ba&ntilde;o de ultrasonido durante 10 min.</p>      <p>Los recubrimientos fueron aplicados por una metodolog&iacute;a previamente reportada<sup>19, 21, 23-25</sup> que incluye la mezcla de reactivos precursores de s&iacute;lice como TEOS (trietilortosilicato) y MTES (metiltrietoxisilano), etanol como solvente y acido ac&eacute;tico como catalizador. Para la aplicaci&oacute;n de los recubrimientos se us&oacute; el m&eacute;todo de inmersi&oacute;n-extracci&oacute;n a una velocidad constante de 4 cm/min y posteriormente se realiz&oacute; un tratamiento t&eacute;rmico a 450 &deg;C durante media hora.</p>      <p>Para el control de calidad de los recubrimientos, se hizo una inspecci&oacute;n visual por microscopia &oacute;ptica y fueron descartados los recubrimientos con discontinuidades. Los alambres seleccionados fueron analizados por microscopia electr&oacute;nica de barrido antes y despu&eacute;s de ser incorporados en las pruebas.</p>      <p><b>Pruebas de fricci&oacute;n</b></p>      <p>Para las pruebas de fricci&oacute;n se dise&ntilde;&oacute; un adaptador acr&iacute;lico como soporte para los brackets y los alambres, el cual fue acoplado a una m&aacute;quina de pruebas Test resources &ndash; 650R<sup>&reg;</sup>.</p>      <p>Despu&eacute;s de posicionar el bracket, alambre y ligadura se aplic&oacute; la carga a una velocidad constante de cinco mm/min durante dos minutos<sup>26</sup> a temperatura ambiente (21 &plusmn; 2 &deg;C) siguiendo el diagrama de fuerzas de la <a href="#f1">figura 1</a>. Se obtuvieron gr&aacute;ficas de la relaci&oacute;n carga posici&oacute;n (N/mm), y el punto m&aacute;s alto de la gr&aacute;fica (momento en el cual se vence la fuerza de fricci&oacute;n est&aacute;tica entre las superficies) fue tomado como el valor de la fuerza de fricci&oacute;n est&aacute;tica para el an&aacute;lisis estad&iacute;stico (<a href="#f2">figura 2</a>).</p>      ]]></body>
<body><![CDATA[<p align="center"><a name="f1"><img src=img/revistas/rfoua/v20n2/v20n2a07f1.jpg></a> </p>      <p align="center"><a name="f2"><img src=img/revistas/rfoua/v20n2/v20n2a07f2.jpg></a> </p>      <p><b>Pruebas de flexi&oacute;n de los alambres</b></p>      <p>Se evaluaron las propiedades el&aacute;sticas de cada uno de los alambres, por medio de una prueba de flexi&oacute;n de tres puntos, utilizando la m&aacute;quina de pruebas Test resources<sup>TM</sup> &ndash; 650R con una celda de carga de 250 lb.</p>      <p><b>An&aacute;lisis estad&iacute;stico</b></p>      <p>Para el an&aacute;lisis de la fricci&oacute;n est&aacute;tica y din&aacute;mica se utiliz&oacute; el paquete estad&iacute;stico SPSS versi&oacute;n 14.0, con el cual se hicieron an&aacute;lisis univariados y bivariados para las variables en cada tratamiento, material y resistencia friccional, resultante de las pruebas en los tres tipos de arcos. Para cada grupo de arcos probados se calcularon estad&iacute;sticas descriptivas como promedios, desviaci&oacute;n est&aacute;ndar, medianas y rangos. Se compararon las medias de los valores de resistencia friccional entre las diferentes combinaciones arco-bracket para determinar si exist&iacute;a una diferencia significativa con un nivel de significaci&oacute;n estad&iacute;stica del 5%, previamente se verific&oacute; si los datos segu&iacute;an una distribuci&oacute;n de probabilidad normal por medio de la prueba de normalidad de Shapiro-Wilk para cada una de las combinaciones. La anterior prueba mostr&oacute; que la significaci&oacute;n para los tres tipos de arcos era menor de 0,05, descartando as&iacute; la posibilidad de aceptar que los datos siguen un comportamiento normal.</p>      <p>Posteriormente se hizo la prueba U de Mann-Whitney en la cual se compararon las medias por parejas de grupos con el fin de determinar cu&aacute;l o cu&aacute;les de los grupos en comparaci&oacute;n fueron los que presentaron diferencias.</p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>      <p><b>Fricci&oacute;n est&aacute;tica</b></p>      ]]></body>
<body><![CDATA[<p>Los resultados de las pruebas de fricci&oacute;n est&aacute;tica muestran que el grupo control present&oacute; la menor fricci&oacute;n promedio (0,215 &plusmn; 0,06 N) seguido del grupo Sol-Gel (0,256 &plusmn; 0,07 N) y el grupo t&eacute;rmico (0,353 &plusmn; 0,12 N), el cual mostr&oacute; la mayor fricci&oacute;n est&aacute;tica. Seg&uacute;n la prueba U de Mann-Whitney se encontraron diferencias entre las medianas de los grupos comparados por parejas, grupo control: 0,20 N, grupo Sol-Gel: 0,25 N y grupo t&eacute;rmico 0,33 N.</p>      <p><b>Fricci&oacute;n din&aacute;mica</b></p>      <p>Los resultados de las pruebas de fricci&oacute;n din&aacute;mica muestran que el grupo Sol-Gel present&oacute; la menor fricci&oacute;n promedio (0,109 &plusmn; 0,06 N) seguido del grupo control (0,135 &plusmn; 0,04 N) y el grupo t&eacute;rmico (0,215 &plusmn; 0,09 N), el cual mostr&oacute; la mayor fricci&oacute;n din&aacute;mica.</p>      <p>La prueba U de Mann-Whitney utilizada para comparar los grupos control y Sol-Gel t&eacute;rmico-Sol-Gel, mostr&oacute; diferencias entre las medianas de los grupos comparados. Igualmente la prueba t-Student utilizada para determinar la diferencia entre las medias de los grupos control y t&eacute;rmico mostr&oacute; diferencias entre estos.</p>      <p><b>An&aacute;lisis de la topograf&iacute;a superficial</b></p>      <p>Las im&aacute;genes de microscopia &oacute;ptica mostraron superficies lisas tanto en el grupo control como en el grupo Sol-Gel, mientras que en el grupo t&eacute;rmico se presentaron superficies irregulares con &aacute;reas oscuras  compatibles con oxidaci&oacute;n del alambre. En algunos casos se desecharon alambres del grupo Sol-Gel, ya que en algunos alambres se obtuvo un recubrimiento con defectos tales como grietas, poros y presencia de puntos negros.</p>      <p>Las im&aacute;genes de microscopia electr&oacute;nica de barrido (SEM) a 1.000 y 2.500X antes y despu&eacute;s de las pruebas, mostraron diferencias entre los tres grupos evaluados. Los grupos de control y Sol- Gel presentaron marcas de desgaste despu&eacute;s de la prueba de deslizamiento, mientras que el grupo t&eacute;rmico exhibi&oacute; una superficie pulida con ligeros rasgos de desgaste y eliminaci&oacute;n de &oacute;xido superficial producido en el tratamiento t&eacute;rmico. El grupo Sol-Gel mostr&oacute; trazas de remoci&oacute;n del cer&aacute;mico en direcci&oacute;n del deslizamiento, debido en algunos casos a desprendimiento del recubrimiento y a una adherencia insuficiente para resistir la fuerza aplicada desde el bracket (<a href="#f3">figura 3</a>).</p>      <p align="center"><a name="f3"><img src=img/revistas/rfoua/v20n2/v20n2a07f3.jpg></a> </p>      <p>Los alambres del grupo control antes de la prueba de deslizamiento mostraron una superficie m&aacute;s pulida en comparaci&oacute;n con los alambres despu&eacute;s de la prueba, debido al desgaste cuando se desliz&oacute; sobre la ranura. Igual sucedi&oacute; con los alambres del grupo Sol-Gel antes de la prueba, los cuales presentaron una superficie m&aacute;s homog&eacute;nea y lisa que los alambres usados del mismo grupo y los alambres de los dem&aacute;s grupos (control y t&eacute;rmico).</p>      <p>Los alambres usados del grupo Sol-Gel mostraron l&iacute;neas horizontales de abrasi&oacute;n (desprendimiento del material) en la misma direcci&oacute;n del deslizamiento. Los alambres nuevos del grupo t&eacute;rmico mostraron una superficie irregular (con &aacute;reas de oxidaci&oacute;n) frente a los usados del mismo grupo y todos los dem&aacute;s alambres (<a href="#f3">figura 3</a>).</p>      ]]></body>
<body><![CDATA[<p>Sobre el bracket tambi&eacute;n se evidenci&oacute; desgaste en la superficie de la ranura, al igual que remoci&oacute;n de part&iacute;culas c&uacute;bicas (2,5 &micro;m), con gran concentraci&oacute;n de calcio seg&uacute;n an&aacute;lisis qu&iacute;mico; las cuales estaban incrustadas en la superficie, posiblemente procedentes del abrasivo del proceso de fabricaci&oacute;n (<a href="#f4">figura 4</a>). </p>      <p align="center"><a name="f4"><img src=img/revistas/rfoua/v20n2/v20n2a07f4.jpg></a> </p>      <p>La evaluaci&oacute;n superficial de los brackets nuevos tambi&eacute;n mostr&oacute; que los bordes de las ranuras de los brackets presentan una superficie muy irregular, mientras que la regi&oacute;n central de la ranura del bracket present&oacute; una superficie lisa y homog&eacute;nea. En cuanto a las ligaduras el&aacute;sticas usadas, mostraron deformaci&oacute;n pl&aacute;stica cuando fueron comparadas con las ligaduras nuevas (<a href="#f5">figura 5</a>).</p>      <p align="center"><a name="f5"><img src=img/revistas/rfoua/v20n2/v20n2a07f5.jpg></a> </p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      <p>Los alambres de acero (grupo control) mostraron la menor fuerza de fricci&oacute;n est&aacute;tica en las mec&aacute;nicas de deslizamiento con respecto a los grupos Sol-Gel y t&eacute;rmico, lo cual concuerda con lo reportado por estudios previos<sup>27</sup> en los cuales los aceros han mostrado din&aacute;micas friccionales predominantemente m&aacute;s bajas que otros materiales. Sin embargo, frente a la fuerza de fricci&oacute;n din&aacute;mica, el grupo Sol-Gel present&oacute; la menor fuerza de fricci&oacute;n (0,109 N), seguida por el grupo control (0,135 N) y finalmente el grupo t&eacute;rmico (0,215 N).</p>      <p>En este estudio se evidenciaron diferencias estad&iacute;sticamente significativas para la fricci&oacute;n est&aacute;tica entre el grupo control y el grupo Sol-Gel, mientras que el comportamiento de la fricci&oacute;n din&aacute;mica mostr&oacute; tendencia a la disminuci&oacute;n progresiva en el grupo Sol-Gel. En el grupo control la fricci&oacute;n din&aacute;mica no presenta variaciones muy bruscas a medida que se desliza el alambre. Para el grupo control con un valor medio 0,135 N, se encontr&oacute; que la fuerza de fricci&oacute;n din&aacute;mica representa el 63% de la fuerza de fricci&oacute;n est&aacute;tica. La fricci&oacute;n din&aacute;mica para el grupo Sol-Gel se ubic&oacute; aproximadamente en 0,109 N, que representa el 43% de la fricci&oacute;n est&aacute;tica para este grupo (<a href="#f2">figura 2</a>).</p>      <p>El grupo t&eacute;rmico present&oacute; una gr&aacute;fica m&aacute;s irregular, y la fricci&oacute;n din&aacute;mica fue en promedio de 0,215 N, representando el 61% de la fuerza de fricci&oacute;n est&aacute;tica. Las im&aacute;genes SEM de la figura 3 (columna derecha) permiten deducir que este comportamiento mec&aacute;nico es debido a la remoci&oacute;n del &oacute;xido de hierro a medida que se realiz&oacute; el deslizamiento sobre el bracket. En este caso la capa de &oacute;xido de hierro presente sobre la superficie del alambre no favoreci&oacute; la disminuci&oacute;n de la fuerza de fricci&oacute;n ni est&aacute;tica ni din&aacute;mica ya que la fuerza normal fue relativamente grande (entre 3,9 y 4,2 N).<sup>3, 28</sup></p>      <p>El grupo t&eacute;rmico sufri&oacute; una velocidad de enfriamiento que probablemente modific&oacute; sus propiedades f&iacute;sicas, ya que como es sabido, si el enfriamiento del acero se da de una forma m&aacute;s r&aacute;pida los &aacute;tomos de cromo presentes en la aleaci&oacute;n se ubicar&aacute;n alrededor de los granos en donde con frecuencia se ubican los &aacute;tomos de carbono, generando una superficie del grano vulnerable a la oxidaci&oacute;n, lo cual se pueden apreciar en las im&aacute;genes de SEM en los alambres nuevos del grupo t&eacute;rmico (<a href="#f3">figura 3</a>).</p>      ]]></body>
<body><![CDATA[<p>Las im&aacute;genes SEM del grupo Sol-Gel (figura 3) mostraron que la superficie de este es m&aacute;s homog&eacute;nea que la de los otros dos grupos evaluados antes del deslizamiento, lo cual supondr&iacute;a mejora en la topograf&iacute;a superficial de los alambres de este grupo, generando unas caracter&iacute;sticas m&aacute;s adecuadas para la mec&aacute;nica de deslizamiento. Sin embargo, las im&aacute;genes posteriores al deslizamiento dejan ver alto grado de da&ntilde;o en el recubrimiento, por desprendimiento debido a las fallas en la adherencia al sustrato y el rayado como consecuencia de la diferencia de dureza con respecto al acero AISI 303 del bracket. Este rayado se supone debido a que la fuerza normal es aplicada en los bordes de la ranura del bracket, en donde la ligadura genera mayor presi&oacute;n contra el alambre y el bracket. La concentraci&oacute;n de fuerzas en estos puntos aumenta la penetraci&oacute;n del borde del bracket sobre el alambre y as&iacute; se generan los da&ntilde;os en el alambre. Recubrimientos cer&aacute;micos r&iacute;gidos tienden a ser m&aacute;s vulnerables a la fractura conforme aumenta el espesor de la pel&iacute;cula.</p>      <p><b>Comportamiento de la curva fricci&oacute;n</b></p>      <p>Se presentaron curvas representativas de cargadeslizamiento medidas para los grupos control, Sol-Gel y t&eacute;rmico, respectivamente (<a href="#f2">figura 2</a>). En las tres curvas se puede distinguir aumento r&aacute;pido en la fuerza est&aacute;tica y luego una zona de descenso r&aacute;pido que se interpreta como el inicio del movimiento del alambre pasando a la fuerza din&aacute;mica, esta zona corresponde a un acomodamiento de las superficies en el nuevo estado de movimiento.</p>      <p>Resulta dif&iacute;cil determinar si la naturaleza de la fuerza de la ligadura es el&aacute;stica o si ya se ha entrado en la zona pl&aacute;stica del pol&iacute;mero; sin embargo, las im&aacute;genes en SEM que comparan una ligadura antes y despu&eacute;s de su uso, permiten comprobar que las ligaduras al montarlas en el bracket y deslizar sobre ellas los alambres sobrepasan el l&iacute;mite el&aacute;stico (<a href="#f5">figura 5</a>).</p>      <p>La siguiente zona en los diagramas de fuerza de fricci&oacute;n corresponde a la transici&oacute;n donde se presenta fuerza de fricci&oacute;n estable durante todo el movimiento, que se caracteriza por presentar concavidad positiva durante toda esta zona. Finalmente, la curva toma una tendencia relativamente estable; es decir, sin tendencia predominantemente creciente ni decreciente. Despu&eacute;s del primer pico, todos los gr&aacute;ficos presentan comportamiento de aumento y descenso en la fuerza de fricci&oacute;n din&aacute;mica, este fen&oacute;meno se conoce como stick-slip (comportamiento alternativo de movimiento y parada entre el alambre y el bracket en el deslizamiento); en este caso se puede inferir que la fuerza de fricci&oacute;n din&aacute;mica corresponde al valor intermedio entre picos consecutivos ascendentes y descendentes. Aunque las mismas zonas pueden ser observadas en gr&aacute;ficos de fricci&oacute;n presentados por Michelberger,<sup>29</sup> los valores y el comportamiento de las curvas difiere bastante con respecto a las medidas en esta investigaci&oacute;n (<a href="#f2">figura 2</a>).</p>      <p>El sistema de deslizamiento que se est&aacute; presentando en este modelo de pruebas relaciona tres superficies en contacto (ligadura el&aacute;stica-alambre-bracket), por lo tanto es importante tener en cuenta que los resultados y el comportamiento de la dupla alambrebracket est&aacute; influenciada por el sistema de ligado.</p>      <p><b>Vibraci&oacute;n friccional</b></p>      <p>En el fen&oacute;meno de stick-slip se debe tener en cuenta que el alambre est&aacute; en contacto con dos superficies totalmente diferentes. Por una parte est&aacute; un acero inoxidable AISI 303 (bracket) y por otra poliuretano libre de l&aacute;tex (ligadura), para el primero, la interacci&oacute;n de dos materiales r&iacute;gidos met&aacute;licos, la fuerza friccional es m&aacute;s de car&aacute;cter topogr&aacute;fico en t&eacute;rminos de los defectos superficiales de ambos materiales (bracket-alambre), en el segundo caso, la ligadura no requiere fuerzas normales muy grandes para presentar deformaciones pl&aacute;sticas entre los defectos del acero del alambre aumentando el &aacute;rea de contacto entre superficies. Como ha sido reportado, el tipo de ligado puede variar el comportamiento de la fricci&oacute;n tanto est&aacute;tica como din&aacute;mica.<sup>10, 30</sup> Estos dos fen&oacute;menos contribuyen a generar un bloqueo mec&aacute;nico entre superficies que aumenta la fuerza de fricci&oacute;n din&aacute;mica.</p>      <p><b>Pruebas de flexi&oacute;n en los alambres</b></p>      <p>Las pruebas de flexi&oacute;n de los alambres mostraron que el grupo Sol-Gel present&oacute; mayor rigidez al ser comparado con los dem&aacute;s grupos. Lo anterior, aunque confirma lo reportado en investigaciones previas, no corresponde a este caso ya que estos autores concluyen que al aumentar el espesor del alambre igualmente aumenta su rigidez.<sup>16, 31</sup> En este caso, los espesores de las capas delgadas (2,5 &micro;m) no son un aporte significativo en el espesor del alambre pero puede interpretarse como la aplicaci&oacute;n de un refuerzo con mayor m&oacute;dulo de rigidez sobre la periferia del alambre que mejora su resistencia a la flexi&oacute;n.</p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>Los valores m&aacute;s bajos de fuerza de fricci&oacute;n est&aacute;tica fueron obtenidos con los alambres del grupo control, seguidos del grupo Sol-Gel y el grupo t&eacute;rmico. Para la fricci&oacute;n din&aacute;mica, los menores valores de fuerza de fricci&oacute;n fueron obtenidos con el grupo Sol-Gel, seguido del grupo control y el grupo t&eacute;rmico. En este estudio in vitro los recubrimientos v&iacute;treos aplicados por Sol-Gel no presentaron una adherencia compatible con la fricci&oacute;n en mec&aacute;nica de ortodoncia.</p>      <p>Estudios futuros podr&iacute;an enfocarse a evaluar modificaciones en el tama&ntilde;o de la ranura del bracket, en el uso de alambres m&aacute;s r&iacute;gidos y en el uso de otras t&eacute;cnicas de recubrimiento para intentar encontrar una disminuci&oacute;n en la resistencia friccional.</p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>REFERENCIAS BIBLIOGR&Aacute;FICAS</b></font></p>      <!-- ref --><p>1. Kusy RP. Orthodontic biomechanics: vistas from the top of a new century. Am J Orthod Dentofacial Orthop 2000; 117: 589-591.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0121-246X200900010000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Kusy RP. Ongoing innovations in biomechanics and materials for the new millennium. Angle Orthod 2000; 70: 366-376.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0121-246X200900010000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Kusy RP, Whitley JQ. Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots. I. The dry state. Am J Orthod Dentofacial Orthop 1990; 98: 300-312.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0121-246X200900010000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Drescher D, Bourauel C, Schumacher HA. Frictional forces between bracket and arch wire. Am J Orthod Dentofacial Orthop 1989; 96: 397-404.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0121-246X200900010000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Rendon L, Cano G, Pel&aacute;ez A, Jaramillo P, Garc&iacute;a C, Montoya Y. Evaluaci&oacute;n in vitro de la resistencia friccional entre brackets cer&aacute;micos y arcos de acero inoxidable con y sin recubrimiento v&iacute;treo aplicado por el m&eacute;todo Sol-Gel. Rev Fac Odontol Univ Antioq 2008; 20: 58-71.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0121-246X200900010000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. T horstenson GA, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop 2002; 122: 295-305.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0121-246X200900010000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Angolkar PV, Kapila S, Duncanson MG, Jr., Nanda RS. Evaluation of friction between ceramic brackets and orthodontic wires of four alloys. Am J Orthod Dentofacial Orthop 1990; 98: 499-506.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0121-246X200900010000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Kusy RP. Influence on binding of third-order torque to second-order angulation. Am J Orthod Dentofacial Orthop 2004; 125: 726-732.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0121-246X200900010000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Kusy RP, Whitley JQ. Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding. Angle Orthod 1999; 69: 71-80.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X200900010000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Shivapuja PK, Berger J. A comparative study of conventional ligation and self-ligation bracket systems. Am J Orthod Dentofacial Orthop 1994; 106: 472-480.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0121-246X200900010000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Griffiths HS, Sherriff M, Ireland AJ. Resistance to sliding with 3 types of elastomeric modules. Am J Orthod Dentofacial Orthop 2005; 127: 670-675; 754.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X200900010000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Stannard JG, Gau JM, Hanna MA. Comparative friction of orthodontic wires under dry and wet conditions. Am J Orthod 1986; 89: 485-491.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0121-246X200900010000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Articolo LC, Kusy K, Saunders CR, Kusy RP. Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment. Eur J Orthod 2000; 22: 409-425.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X200900010000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Articolo LC, Kusy RP. Influence of angulation on the resistance to sliding in fixed appliances. Am J Orthod Dentofacial Orthop 1999; 115: 39-51.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0121-246X200900010000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Bobadilla M, Montoya Y. Medicion in vitro de la fuerza de friccion en duplas arco-brackets con angulacion. Rev Ing Biomed 2008; 2: 84-90.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X200900010000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Tidy DC. Frictional forces in fixed appliances. Am J Orthod Dentofacial Orthop 1989; 96: 249-254.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X200900010000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Kusy RP, Tobin EJ, Whitley JQ, Sioshansi P. Frictional coefficients of ion-implanted alumina against ion-implanted beta-titanium in the low load, low velocity, single pass regime. Dent Mater 1992; 8: 167-172.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X200900010000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Abad P. Tratamientos superficiales y recubrimientos. Cuad Ceram y Vit 1999; 8: 11-18.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0121-246X200900010000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. Garc&iacute;a C. Bioactivaci&oacute;n de metales de uso ortop&eacute;dico mediante recubrimientos producidos por Sol-Gel. Madrid: Universidad Aut&oacute;noma de Madrid; 2004.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X200900010000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Dur&aacute;n A, Conde A, G&oacute;mez Coedo A, Dorado T, Garc&iacute;a C, Cer&eacute; S. Sol-Gel coatings for protection and bioactivation of metals used in orthopaedic devices. J Mater Chem 2004; 14: 2282-2290.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0121-246X200900010000700020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Pel&aacute;ez A, Pareja A, Garc&iacute;a C, M&aacute;rquez M, Toro A, Casta&ntilde;eda R et al. Genotoxicity Effects of ceramic coating applied on metallic substrates using single cell gel electrophoresis Assay in vitro. Key Eng Mater 2005; 284-285: 593-596.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X200900010000700021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Haddow DB, James PF, VanNoort R. Characterization of Sol-Gel surfaces for biomedical applications. J Mater Sci Mater Med 1996; 7: 255-260.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0121-246X200900010000700022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23. Garc&iacute;a C, Galliano P, Cere S. Electrochemical evaluation of resistance to localised corrosion of vitreous coatings containing particles applied on metallic substrates for biomedical applications. Mater Letters 2003; 57: 1810-1814.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0121-246X200900010000700023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24. Garc&iacute;a C, Cere S, Dur&aacute;n A. Bioactive coatings prepared by Sol-Gel on stainless steel 316L. J Non-Crystal Solids 2004; 348: 218-224.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0121-246X200900010000700024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25. Pel&aacute;ez A, Garc&iacute;a C, Correa J, Abad P. Reliability weibull analysis for structural evaluation of bioactive films obtained by Sol-Gel process. Key Eng Mater 2004; 254-256: 431-434.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0121-246X200900010000700025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Ireland AJ, Sherriff M, McDonald F. Effect of bracket and wire composition on frictional forces. Eur J Orthod 1991; 13: 322-328.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0121-246X200900010000700026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>27. Kusy RP, Whitley JQ. Effects of sliding velocity on the coefficients of friction in a model orthodontic system. Dent Mater 1989; 5: 235-240.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0121-246X200900010000700027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>28. Kusy RP, Mims L, Whitley JQ. Mechanical characteristics of various tempers of as-received cobalt-chromium archwires. Am J Orthod Dentofacial Orthop 2001; 119: 274-291.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0121-246X200900010000700028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>29. Michelberger DJ, Eadie RL, Faulkner MG, Glover KE, Prasad NG, Major PW. The friction and wear patterns of orthodontic brackets and archwires in the dry state. Am J Orthod Dentofacial Orthop 2000; 118: 662-674.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0121-246X200900010000700029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30. T homas S, Sherriff M, Birnie D. A comparative in vitro study of the frictional characteristics of two types of selfligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures. Eur J Orthod 1998; 20: 589-596.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0121-246X200900010000700030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>31. Frank CA, Nikolai RJ. A comparative study of frictional resistances between orthodontic bracket and arch wire. Am J Orthod 1980; 78: 593-609.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0121-246X200900010000700031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>     <p>&nbsp;</p>      <p><b>RECIBIDO: SEPTIEMBRE 9/2008 - ACEPTADO: MARZO 17/2009</b></p>       ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CORRESPONDENCIA</b></font></p>      <p>Claudia Patricia Garc&iacute;a Garc&iacute;a Ph.D.    <br> Universidad Nacional de Colombia    <br> Sede Medell&iacute;n. Departamento de F&iacute;sica    <br> Apartado 38 40. Medell&iacute;n    <br> Correo electr&oacute;nico: <a href="mailto: cpgarcia@unalmed.edu.co">cpgarcia@unalmed.edu.co</a></p>      <p><b>C&oacute;mo citar este art&iacute;culo:</b></p>       <p>Valencia JA, Montoya Y, Pel&aacute;ez A, Jaramillo PM, Garc&iacute;a G. Evaluaci&oacute;n de la fricci&oacute;n en arcos ortod&oacute;ncicos de acero inoxidable con y sin recubrimiento v&iacute;treo aplicado por el m&eacute;todo Sol-Gel. Rev Fac Odontol Univ Antioq 2009; 20(2): 161-170.</p>      ]]></body>
<body><![CDATA[<p>Valencia JA, Montoya Y, Pel&aacute;ez A, Jaramillo PM, Garc&iacute;a G. Friction evaluation in stainless steel arches with and withouth glass coating using the Sol-Gel method. Rev Fac Odontol Univ Antioq 2009; 20(2): 161-170.</p>  </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Orthodontic biomechanics: vistas from the top of a new century]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2000</year>
<volume>117</volume>
<page-range>589-591</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ongoing innovations in biomechanics and materials for the new millennium]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2000</year>
<volume>70</volume>
<page-range>366-376</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots: I. The dry state]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1990</year>
<volume>98</volume>
<page-range>300-312</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Drescher]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bourauel]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Schumacher]]></surname>
<given-names><![CDATA[HA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Frictional forces between bracket and arch wire]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1989</year>
<volume>96</volume>
<page-range>397-404</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rendon]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cano]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Peláez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Jaramillo]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación in vitro de la resistencia friccional entre brackets cerámicos y arcos de acero inoxidable con y sin recubrimiento vítreo aplicado por el método Sol-Gel]]></article-title>
<source><![CDATA[Rev Fac Odontol Univ Antioq]]></source>
<year>2008</year>
<volume>20</volume>
<page-range>58-71</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[T]]></surname>
<given-names><![CDATA[horstenson GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2002</year>
<volume>122</volume>
<page-range>295-305</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Angolkar]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
<name>
<surname><![CDATA[Kapila]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Duncanson]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[Nanda]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of friction between ceramic brackets and orthodontic wires of four alloys]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1990</year>
<volume>98</volume>
<page-range>499-506</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence on binding of third-order torque to second-order angulation]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2004</year>
<volume>125</volume>
<page-range>726-732</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>1999</year>
<volume>69</volume>
<page-range>71-80</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shivapuja]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative study of conventional ligation and self-ligation bracket systems]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1994</year>
<volume>106</volume>
<page-range>472-480</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Griffiths]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ireland]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to sliding with 3 types of elastomeric modules]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2005</year>
<volume>127</volume>
<page-range>670-675; 754</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stannard]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Gau]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Hanna]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative friction of orthodontic wires under dry and wet conditions]]></article-title>
<source><![CDATA[Am J Orthod]]></source>
<year>1986</year>
<volume>89</volume>
<page-range>485-491</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Articolo]]></surname>
<given-names><![CDATA[LC]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Saunders]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2000</year>
<volume>22</volume>
<page-range>409-425</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Articolo]]></surname>
<given-names><![CDATA[LC]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of angulation on the resistance to sliding in fixed appliances]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1999</year>
<volume>115</volume>
<page-range>39-51</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bobadilla]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Medicion in vitro de la fuerza de friccion en duplas arco-brackets con angulacion]]></article-title>
<source><![CDATA[Rev Ing Biomed]]></source>
<year>2008</year>
<volume>2</volume>
<page-range>84-90</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tidy]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Frictional forces in fixed appliances]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1989</year>
<volume>96</volume>
<page-range>249-254</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Tobin]]></surname>
<given-names><![CDATA[EJ]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
<name>
<surname><![CDATA[Sioshansi]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Frictional coefficients of ion-implanted alumina against ion-implanted beta-titanium in the low load, low velocity, single pass regime]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>1992</year>
<volume>8</volume>
<page-range>167-172</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abad]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Tratamientos superficiales y recubrimientos]]></article-title>
<source><![CDATA[Cuad Ceram y Vit]]></source>
<year>1999</year>
<volume>8</volume>
<page-range>11-18</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<source><![CDATA[Bioactivación de metales de uso ortopédico mediante recubrimientos producidos por Sol-Gel]]></source>
<year>2004</year>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Universidad Autónoma de Madrid]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Durán]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Conde]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[Coedo A]]></given-names>
</name>
<name>
<surname><![CDATA[Dorado]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ceré]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sol-Gel coatings for protection and bioactivation of metals used in orthopaedic devices]]></article-title>
<source><![CDATA[J Mater Chem]]></source>
<year>2004</year>
<volume>14</volume>
<page-range>2282-2290</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peláez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pareja]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Márquez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Toro]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Castañeda]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Genotoxicity Effects of ceramic coating applied on metallic substrates using single cell gel electrophoresis Assay in vitro]]></article-title>
<source><![CDATA[Key Eng Mater]]></source>
<year>2005</year>
<volume>284-285</volume>
<page-range>593-596</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haddow]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
<name>
<surname><![CDATA[James]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
<name>
<surname><![CDATA[VanNoort]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of Sol-Gel surfaces for biomedical applications]]></article-title>
<source><![CDATA[J Mater Sci Mater Med]]></source>
<year>1996</year>
<volume>7</volume>
<page-range>255-260</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Galliano]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Cere]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrochemical evaluation of resistance to localised corrosion of vitreous coatings containing particles applied on metallic substrates for biomedical applications]]></article-title>
<source><![CDATA[Mater Letters]]></source>
<year>2003</year>
<volume>57</volume>
<page-range>1810-1814</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Cere]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Durán]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bioactive coatings prepared by Sol-Gel on stainless steel 316L]]></article-title>
<source><![CDATA[J Non-Crystal Solids]]></source>
<year>2004</year>
<volume>348</volume>
<page-range>218-224</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peláez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Abad]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability weibull analysis for structural evaluation of bioactive films obtained by Sol-Gel process]]></article-title>
<source><![CDATA[Key Eng Mater]]></source>
<year>2004</year>
<volume>254-256</volume>
<page-range>431-434</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ireland]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[McDonald]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of bracket and wire composition on frictional forces]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>1991</year>
<volume>13</volume>
<page-range>322-328</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of sliding velocity on the coefficients of friction in a model orthodontic system]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>1989</year>
<volume>5</volume>
<page-range>235-240</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Mims]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical characteristics of various tempers of as-received cobalt-chromium archwires]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2001</year>
<volume>119</volume>
<page-range>274-291</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Michelberger]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Eadie]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Faulkner]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[Glover]]></surname>
<given-names><![CDATA[KE]]></given-names>
</name>
<name>
<surname><![CDATA[Prasad]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
<name>
<surname><![CDATA[Major]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The friction and wear patterns of orthodontic brackets and archwires in the dry state]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2000</year>
<volume>118</volume>
<page-range>662-674</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[T]]></surname>
<given-names><![CDATA[homas S]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Birnie]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative in vitro study of the frictional characteristics of two types of selfligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>1998</year>
<volume>20</volume>
<page-range>589-596</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frank]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Nikolai]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative study of frictional resistances between orthodontic bracket and arch wire]]></article-title>
<source><![CDATA[Am J Orthod]]></source>
<year>1980</year>
<volume>78</volume>
<page-range>593-609</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>