<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2012000100002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Comparación de la resistencia al deslizamiento en brackets de autoligado y brackets convencionales ligados con ligadura elastomérica convencional y ligaduras de baja fricción]]></article-title>
<article-title xml:lang="en"><![CDATA[Comparison of resistance to sliding produced by self-ligating Brackets and conventional brackets ligated with conventional Elastomeric ligature and low-friction ligatures]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nieto Uribe]]></surname>
<given-names><![CDATA[Mileny]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Barrera Chaparro]]></surname>
<given-names><![CDATA[Judith Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González Cáceres]]></surname>
<given-names><![CDATA[Ernesto José]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Parra Mazo]]></surname>
<given-names><![CDATA[Ivón Lilian]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Quijada]]></surname>
<given-names><![CDATA[Aleida Cristina]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Fundación Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Fundación Universitaria San Martín Facultad de Posgrados de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Fundación Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<volume>23</volume>
<numero>2</numero>
<fpage>192</fpage>
<lpage>206</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2012000100002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2012000100002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2012000100002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: es importante para el ortodoncista conocer la resistencia al deslizamiento (RD) generada por el método de ligado usado durante la fase de cierre de espacio con mecánica de deslizamiento. El objetivo es comparar in vitro la RD de un tipo de bracket de autoligado con un tipo de bracket convencional combinado con ligaduras elastoméricas de baja fricción y ligadura elastomérica convencional. MÉTODOS: se utilizaronbrackets de autoligado SmartClip (3M®) ybrackets convencionales Gemini (3M®), dos tipos de ligadura elastomérica de baja fricción Slide (Leone®), Synergy (RMO®) y un tipo de ligadura elastomérica convencional Sani-Tie (GAC®). Los sistemas de ligación de los brackets fueron probados con alambre de acero inoxidable calibre 0,019 &times; 0,025?. La resistencia al deslizamiento de la combinación bracket/alambre/ligadura fue medida con un modelo experimental de tres brackets cementados en una placa acrílica, montada en una máquina Instron. Cada combinación fue probada 9 veces consecutivas en estado seco. RESULTADOS: losbrackets Gemini (3M®) con ligadura convencional Sani-tie (GAC®), reportaron valores promedio de 67,3 g y los brackets Gemini (3M®) con ligadura de baja fricción siliconada Synergy (RMO®) de 84,6 g. Losbrackets SmartClip (3M®) y Gemini (3M®) con ligadura elastomérica de baja fricción Slide (Leone®) tuvieron valores promedio similares de 5,0 y 5,4 g, respectivamente, sin diferencias significativas (p = 0,999). CONCLUSIONES: las ligaduras elastoméricas de baja fricción Slide (Leone®), mostraron fuerzas de resistencia al deslizamiento similares a los brackets de autoligado Smartclip (3M®).]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: It is important for the orthodontist to be familiar with the sliding resistance (SR) generated by the ligation method used during the space closure phase with sliding mechanics. The objective of this article is to make an in vitro comparison of the SR produced by a self-ligating bracket and a conventional bracket in combination with low-friction and conventional elastomeric ligatures. METHODS:SmartClip (3M®) self-ligatingbrackets and Gemini (3M®) conventional brackets were used, as well as two types of low-friction elastomeric ligature: Slide (Leone®) and Synergy (RMO®), and one type of conventional elastomeric ligature: Sani-Tie (GAC®).The brackets ligation systems were tested with stainless steel wire of 0.019 &times; 0.025'' caliber. Sliding resistance of the bracketwire- ligature combination was measured with an experimental model of three brackets bonded in an acrylic plate mounted on an Instron machine. Each combination was tested nine consecutive times in dry state. RESULTS: The Gemini (3M®)brackets with a conventional Sani-Tie (GAC®) ligature reported mean values of 67.3 g, while the Gemini (3M®)brackets with low-friction Synergy (RMO®) silicone ligature obtained mean values of 84.6 g. The SmartClip (3M®) and Gemini (3M®)brackets with low-friction Slide (Leone®) elastomeric ligature had similar mean values of 5.0 and 5.4 g respectively, with no significant differences (p = 0.999). CONCLUSIONS: The Slide (Leone®) low-friction elastomeric ligatures showed sliding resistance forces similar to the SmartClip (3M®) self-ligatingbrackets.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[fricción]]></kwd>
<kwd lng="es"><![CDATA[ligadura elastomérica]]></kwd>
<kwd lng="es"><![CDATA[brackets de autoligado]]></kwd>
<kwd lng="en"><![CDATA[friction]]></kwd>
<kwd lng="en"><![CDATA[elastomeric ligature]]></kwd>
<kwd lng="en"><![CDATA[self-ligating brackets]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Comparaci&oacute;n de la resistencia al deslizamiento en <i>brackets</i> de autoligado y <i>brackets</i> convencionales ligados con ligadura elastom&eacute;rica convencional y ligaduras de baja fricci&oacute;n </b></font></p>          <p>&nbsp;</p>           <p>&nbsp;</p>         <p><b>Mileny Nieto Uribe<sup>1</sup>; Judith Patricia Barrera Chaparro<sup>2</sup>; Ernesto Jos&eacute; Gonz&aacute;lez C&aacute;ceres<sup>3</sup>; Iv&oacute;n Lilian Parra Mazo<sup>3</sup>; Aleida Cristina Rodr&iacute;guez Quijada<sup>3</sup> </b></p>         <p>&nbsp;</p>        <p><sup>1</sup> Odont&oacute;loga. Especialista en Ortodoncia, docente de Posgrado de Ortodoncia. Fundaci&oacute;n Universitaria San Mart&iacute;n</p>      <p><sup>2</sup> Odont&oacute;loga. Especialista en Epidemiolog&iacute;a. Docente de Investigaci&oacute;n. Facultad de Posgrados de Odontolog&iacute;a. Fundaci&oacute;n Universitaria San Mart&iacute;n</p>       ]]></body>
<body><![CDATA[<p><sup>3</sup> Ortodoncistas. Posgrado de Ortodoncia. Fundaci&oacute;n Universitaria San Mart&iacute;n</p>      <p>&nbsp;</p>      <p><b>RECIBIDO: MAYO 3/2011-ACEPTADO: NOVIEMBRE 22/2011</b></p>     <p>&nbsp;</p> </font>     <p><font size="2" face="Verdana">Nieto M, Barrera JP, Gonz&aacute;lez EJ, Parra IL, Rodr&iacute;guez AC. Comparaci&oacute;n de la resistencia al deslizamiento en <i>brackets</i> de autoligado y <i>brakets</i> convencionales ligados con la ligadura elastom&eacute;trica convencional y ligaduras de baja fricci&oacute;n. Rev Fac Odontol Univ Antioq 2012; 23(2): 192-206.</font></p>  <font size="2" face="Verdana">    <p>&nbsp;</p>  <hr noshade>       <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> es importante para el ortodoncista conocer la resistencia al deslizamiento (RD) generada por el m&eacute;todo de ligado usado durante la fase de cierre de espacio con mec&aacute;nica de deslizamiento. El objetivo es comparar in vitro la RD de un tipo de bracket de autoligado con un tipo de bracket convencional combinado con ligaduras elastom&eacute;ricas de baja fricci&oacute;n y ligadura elastom&eacute;rica convencional.    <br>  <b>M&Eacute;TODOS:</b> se utilizaronbrackets de autoligado SmartClip (3M<sup>&reg;</sup>) ybrackets convencionales Gemini (3M<sup>&reg;</sup>), dos tipos de ligadura elastom&eacute;rica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>), Synergy (RMO<sup>&reg;</sup>) y un tipo de ligadura elastom&eacute;rica convencional Sani-Tie (GAC<sup>&reg;</sup>). Los sistemas de ligaci&oacute;n de los<i> brackets</i> fueron probados con alambre de acero inoxidable calibre 0,019 &times; 0,025?. La resistencia al deslizamiento de la combinaci&oacute;n bracket/alambre/ligadura fue medida con un modelo experimental de tres <i>brackets</i> cementados en una placa acr&iacute;lica, montada en una m&aacute;quina Instron. Cada combinaci&oacute;n fue probada 9 veces consecutivas en estado seco.    <br>  <b>RESULTADOS:</b> losbrackets Gemini (3M<sup>&reg;</sup>) con ligadura convencional Sani-tie (GAC<sup>&reg;</sup></sub>), reportaron valores promedio de 67,3 g y los brackets Gemini (3M<sup>&reg;</sup>) con ligadura de baja fricci&oacute;n siliconada Synergy (RMO<sup>&reg;</sup>) de 84,6 g. Losbrackets SmartClip (3M<sup>&reg;</sup>) y Gemini (3M<sup>&reg;</sup>) con ligadura elastom&eacute;rica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>) tuvieron valores promedio similares de 5,0 y 5,4 g, respectivamente, sin diferencias significativas (p = 0,999).    ]]></body>
<body><![CDATA[<br>  <b>CONCLUSIONES:</b> las ligaduras elastom&eacute;ricas de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>), mostraron fuerzas de resistencia al deslizamiento similares a los <i>brackets</i> de autoligado Smartclip (3M<sup>&reg;</sup>).</p>      <p><b>Palabras clave:</b> fricci&oacute;n, ligadura elastom&eacute;rica,brackets de autoligado.</p>   <hr noshade>             <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>     <p>El tratamiento ortod&oacute;ncico con extracciones requiere una fase de cierre de espacios, dicha fase se puede realizar de dos maneras; haciendo la retracci&oacute;n inicialmente de los caninos y luego retraer los cuatro dientes anteriores o con la mec&aacute;nica de retracci&oacute;n en masa, retrayendo los seis dientes anteriores en un &uacute;nico momento.<sup>1</sup> Usualmente el cierre en masa se realiza con mec&aacute;nica de deslizamiento, en la cual el alambre se desliza por los <i>brackets</i> posteriores para guiar el movimiento dental, esto requiere el menor grado de fricci&oacute;n posible para permitir el cierre del espacio de manera efectiva.<sup>2,3</sup> La fuerza tangencial que se produce entre dos cuerpos que se encuentran en contacto cuando uno de estos se resiste al movimiento sobre el otro se denomina fricci&oacute;n,<sup>4</sup> por lo tanto, un t&eacute;rmino m&aacute;s preciso para la fricci&oacute;n en ortodoncia es la resistencia al deslizamiento (RD), que se conoce como la oposici&oacute;n al movimiento encontrado por el <i>bracket</i> a medida que trata de deslizarse a lo largo del alambre o viceversa.<sup>5</sup> Por consiguiente, la fuerza que debe aplicarse sobre los dientes tiene que superar la resistencia al deslizamiento para lograr el movimiento ortod&oacute;ncico deseado.<sup>6</sup></p>       <p>La cantidad de fricci&oacute;n generada es proporcional a la fuerza con la que el <i>bracket</i> y el alambre se deben presionar simult&aacute;neamente y depende de factores como: el m&eacute;todo de ligado,<sup>6-12-14</sup> la composici&oacute;n del alambre<sup>11,15,16</sup> la deflexi&oacute;n del alambre,<sup>17</sup> el calibre del arco,<sup>11,15,16</sup> la distancia<i> interbracket</i>,<sup>18</sup> el material del <i>slot</i> del <i>bracket</i>,<sup>19</sup> la lubricaci&oacute;n de la ligadura, entre otros.<sup>6,10,20-22</sup></p>      <p>En la pr&aacute;ctica ortod&oacute;ncica actual, el m&eacute;todo de ligado de mayor uso son las ligaduras elastom&eacute;ricas, porque facilitan la ligaci&oacute;n del arco al <i>bracket</i>, resultando m&aacute;s c&oacute;modo para el paciente; sin embargo, producen mayor fricci&oacute;n que la ligadura met&aacute;lica.<sup>6,7,23</sup> En respuesta a este hecho, surgen nuevos materiales que favorecen la disminuci&oacute;n de la RD, brindan mayor comodidad al paciente y reducen el tiempo de tratamiento y de consulta, tales como los <i>brackets</i> de autoligado y las ligaduras elastom&eacute;ricas de baja fricci&oacute;n.<sup>11,24,21</sup></p>      <p>Los <i>brackets</i> de autoligado han ganado popularidad, debido a que su dise&ntilde;o se caracteriza por presentar un clip que sujeta el arco al <i>bracket</i> o una cubierta que act&uacute;a como una cuarta pared m&oacute;vil que convierte la ranura en un tubo, lo que permite el paso del arco sobre el <i>slot</i> con menor resistencia al deslizamiento;<sup>13</sup> sin embargo, los sistemas de autoligado tienen varias limitaciones, como son la dificultad para lograr la expresi&oacute;n completa de la prescripci&oacute;n del <i>bracket</i>, el manejo cl&iacute;nico en ocasiones es m&aacute;s problem&aacute;tico que con los soportes convencionales, debido a los frecuentes fracasos de los clips, los <i>brackets</i> son m&aacute;s voluminosos y m&aacute;s costosos, y la higiene oral es m&aacute;s dif&iacute;cil debido a la compleja geometr&iacute;a de los mismos.<sup>24</sup> Por tal motivo en la &uacute;ltima d&eacute;cada se han introducido al mercado las ligaduras elastom&eacute;ricas de baja fricci&oacute;n, algunas de estas act&uacute;an como una cubierta pasiva sobre el <i>bracket</i> convencional, permitiendo el libre deslizamiento del alambre sobre el <i>slot</i>,<sup>11</sup> otras presentan en su composici&oacute;n, una adici&oacute;n de silicona con la finalidad de disminuir la RD,<sup>20, 21</sup> por lo cual son altamente resistentes a la pigmentaci&oacute;n, muy suaves y con un excelente estiramiento y recuperaci&oacute;n. Adicionalmente, se debe considerar la relaci&oacute;n existente entre la forma de colocaci&oacute;n de la ligadura elastom&eacute;rica y el dise&ntilde;o mismo del <i>bracket</i>.</p>      <p> Pocos estudios han evaluado la RD proporcionada por las nuevas ligaduras de baja fricci&oacute;n en comparaci&oacute;n con los <i>brackets</i> de autoligado; el objetivo de este estudio fue comparar la RD de un tipo de <i>bracket</i> de autoligado con <i>brackets</i> convencionales combinados con ligaduras elastom&eacute;ricas de baja fricci&oacute;n y ligadura convencional.</p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>M&Eacute;TODOS</b></font></p> Se utiliz&oacute; un modelo experimental que simulaba el segmento bucal posterior derecho del arco superior para determinar la RD producida por un tipo de <i>bracket</i> de autoligado y un tipo de <i>bracket</i> convencional ligado con tres mecanismos diferentes: una ligadura convencional y dos ligaduras de baja fricci&oacute;n.</p>       <p>El modelo consisti&oacute; en una placa de acr&iacute;lico rectangular (12 cm de largo x 4 de ancho x 5 mm de grosor), en la que se cement&oacute; un <i>bracket</i> del segundo premolar superior derecho, un tubo del primer molar superior derecho y un tubo del segundo molar superior derecho <i>slot</i> 0,022 x 0,028'' de la casa comercial 3M<sup>&reg;</sup> (Unitek Monrovia California, USA) a una distancia <i>interbracket</i> de 8 mm entre cada uno, fueron cementados con resina fotocurable (Prime-Dent VLC Orthodontic, Chicago, USA), mediante la utilizaci&oacute;n de un dispositivo creado para la alineaci&oacute;n de los aditamentos a evaluar, el cual elimina toda informaci&oacute;n activa que se pudiera expresar; este dispositivo fue tomado del estudio de Plaza (2010)<sup>23</sup> dise&ntilde;ado especialmente para este fin. Est&aacute; compuesto por un cuerpo hecho en acero inoxidable y un segmento de alambre 0,021 x 0,025'' tambi&eacute;n de acero inoxidable paralelo a la placa de acr&iacute;lico, el cual fue insertado a trav&eacute;s del <i>slot</i> de todos los aditamentos cementados en cada placa, con la finalidad de controlar la exactitud del cementado y expresar la prescripci&oacute;n de los <i>brackets</i>, permitiendo de esta manera en todos los grupos, que el deslizamiento del arco presentara la menor RD posible al momento de la medici&oacute;n (<a href="file:///C|/Users/usuario/Desktop/f1">figuras 1</a>, <a href="#f2">2</a>, <a href="#f3">3</a>).</p>        <p align="center"><a name="f1"><img src=/img/revistas/rfoua/v23n2/v23n2a02f1.jpg></a> </p>      <p align="center"><a name="f2"><img src=/img/revistas/rfoua/v23n2/v23n2a02f2.jpg></a> </p>      <p align="center"><a name="f3"><img src=/img/revistas/rfoua/v23n2/v23n2a02f3.jpg></a> </p>      <p>Se calcul&oacute; una muestra probabil&iacute;stica de 9 modelos para cada combinaci&oacute;n <i>bracket</i>-alambre-ligadura fueron en total 36 modelos de los cuales: 27 modelos correspond&iacute;an abrackets convencionales Gemini (3M<sup>&reg;</sup>), clasificados de la siguiente manera: 9 modelos ligados con ligadura elastom&eacute;rica convencional Sani- Tie GAC<sup>&reg;</sup>, 9 con ligadura elastom&eacute;rica de baja fricci&oacute;n Slide<sup>&reg;</sup> (Leone Orthodontic Products) y 9 con ligadura siliconada de baja fricci&oacute;n Synergy (RMO<sup>&reg;</sup>). Los 9 modelos restantes correspond&iacute;an abrackets de autoligado Smartclip (3M<sup>&reg;</sup>).</p>      <p>Las placas acr&iacute;licas fueron marcadas al respaldo con un c&oacute;digo para cada tipo de combinaci&oacute;n <i>bracket</i>/ligadura, de manera que el evaluador de resultados desconociera el tipo de combinaci&oacute;n medida: A1) Bracket Smartclip (3M<sup>&reg;</sup>); B1) <i>bracket</i> Gemini (3M<sup>&reg;</sup>) ligado con ligadura elastom&eacute;rica (GAC<sup>&reg;</sup>); B2) <i>bracket</i> Gemini (3M<sup>&reg;</sup>), ligado con ligadura siliconada de baja fricci&oacute;n Synergy (RMO<sup>&reg;</sup>); B3) <i>bracket</i> Gemini (3M<sup>&reg;</sup>) con ligadura elastom&eacute;rica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>). Cada combinaci&oacute;n de <i>bracket</i>-ligadura fue medida con un alambre de calibre 0,019'' x 0,025'' de acero inoxidable.</p>      <p>La RD generada por cada modelo de prueba (alambre,brackets y ligaduras elastom&eacute;ricas) fue obtenida utilizando una m&aacute;quina de medici&oacute;n Instron 3344 (Instron Corp, cant&oacute;n, Mass) modelo 2519-106 con capacidad de 2.000 N, con nivel de error de 0,1% y el dispositivo dise&ntilde;ado con base en el estudio de Plaza (2010)<sup>23</sup> elaborado en acero inoxidable, que fue pintado al horno para evitar imantaci&oacute;n, a este dispositivo se le adaptaron los arcos sujetados con tornillos en la parte superior e inferior (<a href="#f4">figuras 4</a>, <a href="#f5">5</a>).</p>     <p>Este dispositivo fue sujetado a la prensa inferior del equipo Instron, la cual es fija, y la placa acr&iacute;lica fue asegurada en la prensa superior del Instron, la cual es m&oacute;vil y se desliza en sentido vertical sobre el dispositivo de medici&oacute;n. Para cada modelo se hizo un desplazamiento de 8 mm, con una velocidad de 5 mm/min (<a href="#f6">figura 6</a>).</p>       ]]></body>
<body><![CDATA[<p align="center"><a name="f4"><img src=/img/revistas/rfoua/v23n2/v23n2a02f4.jpg></a> </p>      <p align="center"><a name="f5"><img src=/img/revistas/rfoua/v23n2/v23n2a02f5.jpg></a> </p>      <p align="center"><a name="f6"><img src=/img/revistas/rfoua/v23n2/v23n2a02f6.jpg></a> </p>      <p>Se registraron los niveles de RD en gramos necesarios para mover el arco a lo largo de los tresbrackets alineados y esos niveles fueron transmitidos a un computador.</p>      <p>Para cada tipo de combinaci&oacute;n <i>bracket</i>-alambre-ligadura, se tom&oacute; una serie de nueve registros de la RD, bajo condiciones secas con temperatura ambiente de 20 &plusmn; 2 &deg;C.</p>      <p>Despu&eacute;s de cada prueba, se retir&oacute; el modelo y se coloc&oacute; otro con un nuevo alambre y nueva ligadura, previa limpieza del <i>bracket</i> con etanol, para disminuir errores durante la medici&oacute;n de cada una de las combinaciones <i>bracket</i>-alambre-ligadura.</p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>AN&Aacute;LISIS ESTAD&Iacute;STICO</b></font></p>      <p>Se digit&oacute; y depur&oacute; la informaci&oacute;n en Excel versi&oacute;n 2007, el procesamiento se realiz&oacute; en el programa para ciencias sociales SPSS versi&oacute;n 15.0.</p>      <p>Para el an&aacute;lisis descriptivo se utiliz&oacute; el promedio aritm&eacute;tico, el m&iacute;nimo, el m&aacute;ximo y la desviaci&oacute;n est&aacute;ndar; para determinar el grado de variabilidad se utiliz&oacute; el coeficiente de variaci&oacute;n (0-10% homog&eacute;neo, 10,1-20% medianamente homog&eacute;neo, &gt; 20% heterog&eacute;neo).</p>      ]]></body>
<body><![CDATA[<p>El intervalo de confianza se determin&oacute; con nivel de confiabilidad al 95%; para determinar el supuesto de normalidad se utiliz&oacute; la prueba Kolgomorov-Smirnov y para la homogeneidad de las varianzas se utiliz&oacute; la prueba de Levene.</p>      <p>Para determinar diferencias en promedios de fricci&oacute;n se utiliz&oacute; el an&aacute;lisis de varianza (ANOVA) y posteriormente la prueba post-Hoc de Dunnet no asumiendo varianzas iguales.</p>      <p>El nivel de significancia fue a = 0,05, para normalidad y heterogeneidad fue de a = 0,10.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>      <p>Se midi&oacute; la resistencia al deslizamiento en 36 <i>brackets</i> y 72 tubos divididos en cuatro grupos de 9 <i>brackets</i> y 18 tubos: Gemini (3M<sup>&reg;</sup>) con ligadura convencional Sani-Tie (GAC<sup>&reg;</sup>), Gemini (3M<sup>&reg;</sup>) con ligadura siliconada de baja fricci&oacute;n Synergy (RMO<sup>&reg;</sup>), Gemini (3M<sup>&reg;</sup>) con ligadura elastom&eacute;rica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>) y SmartClip (3M<sup>&reg;</sup>) utilizando un alambre de calibre 0,019 x 0,025'' de acero inoxidable (Dentaurum <sup>&reg;</sup>). Se observ&oacute; que los <i>brackets</i> con mayor resistencia al deslizamiento fueron los convencionales Gemini (3M<sup>&reg;</sup>) ligados con ligadura convencional Sani-Tie (GAC<sup>&reg;</sup>) con promedio de 67,3 g y Gemini (3M<sup>&reg;</sup>) ligados con ligadura siliconada de baja fricci&oacute;n Synergy (RMO<sup>&reg;</sup>) con un promedio de 84,6 g. Los <i>brackets</i> SmartClip (3M<sup>&reg;</sup>) y Gemini (3M<sup>&reg;</sup>) con ligadura elast&oacute;merica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>), tuvieron valores promedio similares de 5,0 y 5,4 g, respectivamente y mayor coeficiente de variabilidad. Todas las referencias de los <i>brackets</i> cumplieron con el supuesto de una distribuci&oacute;n de normalidad (prueba Kolgomorov-Smirnov) (<a href="#t1e">tabla 1</a> y <a href="#f7">figura 7</a>).     <p align="center"><a name="t1e"><img src=/img/revistas/rfoua/v23n2/v23n2a02t1e.jpg></a> </p>       <p align="center"><a name="f7"><img src=/img/revistas/rfoua/v23n2/v23n2a02f7.jpg></a> </p>      <p>Al aplicar la prueba ANOVA se encontr&oacute; que las varianzas no fueron iguales en todas las combinaciones de resistencia al deslizamiento de losbrackets (prueba de Levene, p = 0,003) (<a href="#t1">tabla 1</a>). Se hicieron pruebas post-Hoc de Dunnet, en las que al comparar los promedios de RD, se encontraron diferencias entre todos los grupos de combinaciones <i>bracket</i>s-alambre-ligadura, excepto cuando se compararon los <i>brackets</i> SmartClip (3M<sup>&reg;</sup>) y los Gemini (3M<sup>&reg;</sup>) con ligadura elastom&eacute;rica de baja fricci&oacute;n Slide (Leone<sup>&reg;</sup>) (p = 0,99) (<a href="#t2e">tabla 2</a>).</p>      <p align="center"><a name="t2e"><img src=/img/revistas/rfoua/v23n2/v23n2a02t2e.jpg></a> </p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      <p>En el presente estudio se compar&oacute; la resistencia al deslizamiento (RD), generada por los <i>brackets</i> de autoligado pasivo (SmartClip 3M<sup>&reg;</sup>) con la RD producida por los <i>brackets</i> convencionales (Gemini 3M<sup>&reg;</sup>) combinados con tres tipos de ligaduras: ligadura elastom&eacute;rica convencional</p>      <p>(Sani-Tie GAC<sup>&reg;</sup>) , ligadura elastom&eacute;rica de baja fricci&oacute;n (Slide Leone<sup>&reg;</sup>) y ligadura elastom&eacute;rica de baja fricci&oacute;n (Synergy RMO<sup>&reg;</sup>); para esto, se utiliz&oacute; un dispositivo dise&ntilde;ado y fabricado espec&iacute;ficamente para simular las condiciones cl&iacute;nicas del segmento posterosuperior derecho de la arcada dental, tomando como referencia un modelo experimental previo.<sup>23</sup></p>      <p>Los resultados de esta investigaci&oacute;n indicaron que los <i>brackets</i> SmartClip 3M<sup>&reg;</sup> y las ligaduras Slide Leone<sup>&reg;</sup> en los <i>brackets</i> Gemini 3M<sup>&reg;</sup> produjeron fuerzas de fricci&oacute;n significativamente inferiores comparadas con las ligaduras Sani-Tie GAC<sup>&reg;</sup> y Synergy RMO<sup>&reg;</sup> en los <i>brackets</i> Gemini 3M<sup>&reg;</sup>, utilizando un arco de acero inoxidable de calibre 0,019 &times; 0,025''.</p>      <p>Similares hallazgos reportan estudios anteriores <sup>9-11, 13, 16, 26</sup> en los que los <i>brackets</i> de autoligado generaron fuerzas de fricci&oacute;n menores que las ligaduras convencionales en <i>brackets</i> convencionales. Adicionalmente, en otros estudios <sup>11, 13, 14, 27 </sup> se hall&oacute; que las ligaduras Slide Leone<sup>&reg;</sup> en <i>brackets</i> convencionales, generaron fuerzas de RD significativamente menores que las ligaduras convencionales en <i>brackets</i> convencionales, debido a que este tipo de ligaduras una vez colocadas en el <i>bracket</i> crean una ligadura pasiva en el <i>slot</i> que hace que el arco quede libre para deslizarse, lo cual brinda capacidad para controlar adecuadamente la fricci&oacute;n durante las diferentes fases del tratamiento, semejando los <i>brackets</i> convencionales a tubos como lo reporta Baccetti.<sup>14</sup></p>      <p>El comportamiento de la RD en este estudio muestra diferencias significativas para los <i>brackets</i> SmartClip 3M<sup>&reg;</sup> (5,0 g) y para las ligaduras Slide Leone<sup>&reg;</sup> en <i>brackets</i> Gemini 3M<sup>&reg;</sup> (5,4 g) comparadas con las ligaduras Sani- Tie GAC<sup>&reg;</sup> enbrackets Gemini 3M<sup>&reg;</sup> (67,3 g), similares a lo reportado por Gandini y colaboradores,<sup>13</sup> quienes utilizaron un modelo experimental de un bracket y cuyos resultados oscilan entre 0,6 g para <i>brackets</i> SmartClip 3M<sup>&reg;</sup>, 0,5 gr para ligaduras Slide Leone<sup>&reg;</sup> y 153,3 g para una ligadura convencional en un <i>bracket</i> convencional. Por su parte, Plaza y colaboradores,<sup>23</sup> utilizando tambi&eacute;n un modelo de un <i>bracket</i> en medio seco reportaron valores de 0,2 N para <i>brackets</i> SmartClip 3M<sup>&reg;</sup> y 2,2 N para ligaduras elastom&eacute;ricas Sani-Tie GAC<sup>&reg;</sup> en <i>brackets</i> Gemini 3M<sup>&reg;</sup>. En otro estudio, Orsi y colaboradores<sup>26</sup> utilizando un modelo experimental de un <i>bracket</i> en medio h&uacute;medo, reportan valores de RD que oscilan entre 0,002 N para <i>brackets </i> SmartClip 3M<sup>&reg;</sup>, 0,004 N para ligaduras Slide Leone<sup>&reg;</sup> y 2,796 N para una ligadura convencional en un <i>bracket</i> convencional. Aunque la RD, reportada en el presente estudio, es a diferente escala, se comporta de manera similar a los estudios presentados en la literatura.</p> </font>     <p><font size="2" face="Verdana">Franchi y colaboradores<sup>27</sup> evaluaron la RD con un modelo de cinco <i>brackets</i> que reproduc&iacute;a el segmento bucal derecho, utilizando una ligadura elastom&eacute;rica no convencional Slide Leone<sup>&reg;</sup>en <i>brackets</i> convencionales y cuatro tipos de <i>bracket</i> de autoligado y encontraron diferencias no significativas entre la fricci&oacute;n producida por los <i>brackets</i> de autoligado y aquellos ligados con ligaduras Slide Leone<sup>&reg;</sup> . De otro lado, Gandini y colaboradores<sup>13</sup> reportaron valores promedio desde 0,1 a 1,2 g, utilizando un modelo de un <i>bracket</i> del incisivo central superior, de autoligado SmartClip 3M<sup>&reg;</sup> y un tipo de <i>bracket</i> convencional (STEP<sup>&reg;</sup> Leone Orthodontic Products), los cuales fueron ligados con una ligadura elastom&eacute;rica no convencional (Slide Leone<sup>&reg;</sup>) y una ligadura convencional (silver minim&oacute;dulos, Leone Orthodontic Products<sup>&reg;</sup>) en arcos NiTi superel&aacute;stico 0,01'' </font><font size="2" face="Verdana"> y acero inoxidable 0,019 x 0,025''. Estos resultados   coinciden con los obtenidos en este estudio donde se   presentaron diferencias no significativas de RD entre <i>brackets</i> SmartClip 3M<sup>&reg;</sup> y <i>brackets</i> convencionales   ligados con ligaduras Slide Leone<sup>&reg;</sup>. Las diferencias en   los valores de RD entre los estudios pueden atribuirse   al modelo intr&iacute;nseco de cada estudio. Ahora bien, diferentes   autores<sup>7, 23, 28-32</sup> han reportado que la ligadura   met&aacute;lica genera menor RD en comparaci&oacute;n con ligaduras   elastom&eacute;ricas convencionales; en este estudio se   descart&oacute; el uso de la ligadura met&aacute;lica como m&eacute;todo de   ligado del arco, debido a la dificultad para estandarizar   la fuerza producida al momento de colocarlas; aunque   existen estudios en los que se han reportado modelos   de estandarizaci&oacute;n, para la utilizaci&oacute;n de las ligaduras   met&aacute;licas.<sup>23</sup></font></p> <font size="2" face="Verdana">    <p>En este estudio se us&oacute; un modelo experimental en medio seco, como lo han descrito otros autores.<sup>6, 8, 9, 11-14, 20, 21, 23, 27, 28</sup> Chimenti y colaboradores,<sup>21</sup> indican que los m&oacute;dulos el&aacute;sticos siliconados reducen la resistencia friccional est&aacute;tica en 23 a 43%, comparados con las ligaduras no siliconadas, aduciendo este comportamiento a que la concentraci&oacute;n de silicona en la superficie permanece m&aacute;s alta en la condici&oacute;n seca y puede ser removida o ablandada por la saliva en la condici&oacute;n h&uacute;meda.</p>      <p>Otros autores<sup>10</sup> reportan que la inmersi&oacute;n en saliva no genera efectos negativos sobre las ligaduras recubiertas de silicona. En contraste, Bortoly y colaboradores<sup>20</sup> no encontraron diferencias significativas en los valores de RD, entre ligaduras siliconadas sometidas a un medio h&uacute;medo y ligaduras siliconadas en medio seco.</p>      ]]></body>
<body><![CDATA[<p>Cuando se compararon los resultados de la RD obtenidos en este estudio para la ligadura Synergy RMO<sup>&reg;</sup> con las ligaduras Sani-Tie GAC<sup>&reg;</sup> en <i>brackets</i> Gemini 3M<sup>&reg;</sup>, se observaron diferencias significativas con valores de 84,6 y de 67,3 g respectivamente, respecto a otra investigaci&oacute;n<sup>21</sup> en la que se encontraron valores menores de RD con las ligaduras siliconadas comparadas con las ligaduras elastom&eacute;ricas no siliconadas debido a los diferentes m&eacute;todos empleados en la cuantificaci&oacute;n de los valores y las condiciones intr&iacute;nsecas de cada estudio. Por su parte Hain y colaboradores<sup>10</sup> reportan diferencias no significativas de RD entre la ligadura siliconada y la ligadura elastom&eacute;rica convencional con 1,8 y 2 N, respectivamente. Aunque existe variabilidad en los resultados de los estudios mencionados, estos no son comparables entre s&iacute;, debido a las diferencias en las caracter&iacute;sticas de los materiales y m&eacute;todos utilizados.</p>      <p>En otros estudios<sup>33, 34 </sup> utilizando ligaduras Sinergy en <i>brackets</i> Synergy RMO<sup>&reg;</sup>, demostraron fuerzas significativamente menores de RD, comparadas con ligaduras convencionales en <i>brackets</i> convencionales. El comportamiento variable de la ligadura Synergy RMO<sup>&reg;</sup> en esta investigaci&oacute;n se atribuye a que esta se dise&ntilde;&oacute; principalmente para el sistema Synergy RMO<sup>&reg;</sup>, dicha ligadura se coloca en las dos aletas centrales de las seis aletas que posee el <i>bracket</i> Synergy<sup>&reg;</sup>, contactando en un solo punto del arco, proporcionando as&iacute; menor RD; estas ligaduras al ser colocadas en las cuatro aletas del <i>bracket</i> Gemini 3M<sup>&reg;</sup> como una ligadura convencional, contacta el arco en dos puntos, generando niveles m&aacute;s altos de RD. Por otra parte, las dimensiones de las ligaduras elastom&eacute;ricas pueden influir de manera significativa sobre la RD, como lo reportan Chimenti y colaboradores.<sup>21</sup> En el presente estudio la ligadura Synergy RMO<sup>&reg;</sup>, por presentar menor tama&ntilde;o con 0,110 en comparaci&oacute;n con la ligadura Sani-tie GAC<sup>&reg;</sup> con 0,120'', podr&iacute;a ejercer mayor presi&oacute;n sobre el arco al colocarlas en el <i>bracket</i> Gemini 3M<sup>&reg;</sup> aumentando los niveles de resistencia al deslizamiento.</p>      <p>Por esto se recomienda a las casas comerciales suministrar informaci&oacute;n precisa acerca de las aplicaciones de las nuevas ligaduras de baja fricci&oacute;n para que el cl&iacute;nico tenga control sobre las caracter&iacute;sticas del material.</p>      <p>Los resultados de este estudio son una gu&iacute;a &uacute;til para el desarrollo de nuevos criterios y herramientas de trabajo para el ortodoncista, que pueden ser aplicadas en la pr&aacute;ctica diaria, de manera que el cl&iacute;nico pueda ofrecer beneficios en cuanto a la efectividad de las biomec&aacute;nicas aplicadas habitualmente en los tratamientos ortod&oacute;ncicos. Estos resultados deben ser utilizados solo para las comparaciones, ya que un estudio <i>in vitro</i> no puede reflejar completamente el modo de resistencia a la fricci&oacute;n que se produce realmente <i>in vivo</i>, pues pueden influir la saliva, la acumulaci&oacute;n de placa bacteriana y la temperatura de la cavidad oral como agentes coadyuvantes en el aumento de los valores de RD.</p>       <p>Con base en los resultados obtenidos en este estudio, las ligaduras Slide Leone<sup>&reg;</sup> en<i>brackets</i> convencionales Gemini 3M<sup>&reg;</sup> producen niveles significativamente m&aacute;s bajos de RD que las ligaduras Sani- tie GAC<sup>&reg;</sup> en<i> brackets</i> convencionales Gemini 3M<sup>&reg;</sup>, de modo que se puede sugerir el uso de la ligadura Slide Leone<sup>&reg;</sup> en <i>brackets</i> convencionales en la fase de cierre de espacio con mec&aacute;nica de deslizamiento, con la expectativa que el alambre en el sector posterior se deslice de manera f&aacute;cil y r&aacute;pida, a trav&eacute;s, del slot de los <i>brackets</i> posteriores. De ser as&iacute;, este tipo de ligaduras representar&iacute;a una alternativa a los <i>brackets</i> de autoligado una vez comprobada su eficacia en estudios <i>in vivo</i>, por sus niveles de RD similares demostrados en estudios <i>in vitro</i>.</p>      <p>Se encontr&oacute; que el uso de las ligaduras elastom&eacute;ricas de baja fricci&oacute;n Synergy RMO<sup>&reg;</sup> proporcionan valores altos de RD cuando son utilizadas en<i> brackets</i> convencionales, por lo cual se recomienda su uso exclusivo con los<i> brackets</i> Synergy<sup>&reg;</sup> o cuando se requiera aumentar la RD, controlando con esto la p&eacute;rdida de torque o tip que se pueda generar en la fase de cierre de espacios con <i>brackets</i> convencionales. De igual manera se puede plantear la necesidad de realizar la comparaci&oacute;n entre los diferentes tipos de ligado que presentan los <i>brackets</i> Synergy <sup>&reg;</sup> debido a la versatilidad de su dise&ntilde;o de seis aletas.</p>      <p>Esta investigaci&oacute;n proporciona evidencia cient&iacute;fica como apoyo para futuras investigaciones, de manera que estos hallazgos orienten la toma de decisiones en la pr&aacute;ctica al momento de escoger el m&eacute;todo de ligado de los<i>brackets</i>.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>1. Los <i>brackets</i> de autoligado Smartclip 3M<sup>&reg;</sup>, presentaron el comportamiento esperado, con la menor RD durante la fase de movimiento evaluado en el presente estudio.</p>      ]]></body>
<body><![CDATA[<p>2. Las ligaduras elastom&eacute;ricas de baja fricci&oacute;n Slide Leone<sup>&reg;</sup> en <i>brackets</i> convencionales Gemini 3M<sup>&reg;</sup>, presentaron fuerzas de RD similares a los <i>brackets</i> de autoligado Smartclip 3M<sup>&reg;</sup>, utilizando alambre de acero inoxidable de calibre 0,019'' x 0,025''.</p>      <p>3. Las ligaduras Synergy RMO<sup>&reg;</sup> de baja fricci&oacute;n utilizadas en <i>brackets</i> convencionales Gemini 3M<sup>&reg;</sup> presentan mayor RD que las ligaduras elastom&eacute;ricas convencionales Sani-Tie GAG<sup>&reg;</sup> en <i>brackets</i> convencionales Gemini 3M<sup>&reg;</sup>, utilizando alambre de acero inoxidable de calibre 0,019 x 0,025''.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>      <!-- ref --><p>1. Miles PG. Self&#8212;ligating vs. conventional twin brackets during en-masse space closure with sliding mechanics. Am J Orthod Dentofacial Orthop 2007; 132(2): 223-225.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0121-246X201200010000200001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>2. Drescher D, Bourauel C, Schumacher HA. Frictional forces between bracket and arch wire. Am J Orthod Dentofacial Orthop 1989; 96(5): 397-404.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0121-246X201200010000200002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>3. Kapila S, Angolkar PV, Duncanson MG Jr, Nanda RS. Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys. Am J Orthod Dentofacial Orthop 1990; 98(2): 117-126.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0121-246X201200010000200003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<p>4. Dowling PA, Jones WB, Lagerstrom L, Sandham JA. An investigation into the behavioural characteristics of orthodontic elastomeric modules. Br J Orthod 1998; 25(3): 197-202.</p>      <!-- ref --><p>5. Thorstenson G, Kusy R. Influence of stainless steel inserts on the resistance to sliding of esthetic brackets with secondorder angulation in the dry and wet states. Angle Orthod 2003; 73(2): 167-175.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0121-246X201200010000200005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>6. Hain M, Dhopatkar A, Rock P. The effect of ligation method on friction in sliding mechanics. Am J Orthod Dentofacial Orthop 2003; 123(4): 416-242.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0121-246X201200010000200006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>7. Thorstenson GA, Kusy RP. Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states. Angle Orthod 2003; 73(4): 418-430.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0121-246X201200010000200007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>8. Baccetti T, Franchi L, Camporesi M, Defraia E, Barbato E. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth. Angle Orthod 2009; 79(3): 533-539.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0121-246X201200010000200008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>9. Griffiths HS, Sherriff M, Ireland AJ. Resistance to sliding with 3 types of elastomeric modules. Am J Orthod Dentofacial Orthop 2005; 127(6): 670-675.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0121-246X201200010000200009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>10. Hain M, Dhopatkar A, Rock P. A comparison of different ligation methods on friction. Am J Orthod Dentofacial Orthop 2006;130(5): 666-670.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0121-246X201200010000200010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>11. Tecco S, Di Iorio D, Cordasco G, Verrocchi I, Festa F. An in vitro investigation of the influence of self-ligating brackets, low-friction ligatures, and archwire on frictional resistance. Eur J Orthod 2007; 29(4): 390-397.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0121-246X201200010000200011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>12. Camporesi M, Baccetti T, Franchi L. Forces released by esthetic preadjusted appliances with low-friction and conventional elastomeric ligatures. Am J Orthod Dentofacial Orthop 2007; 131(6): 772-725.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0121-246X201200010000200012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>13. Gandini P, Orsi L, Bertoncini C, Massironi S, Franchi L. In vitro frictional forces generated by three different ligation methods. Angle Orthod 2008; 78(5): 917-921.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0121-246X201200010000200013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>14. Baccetti T, Franchi L. Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance. Angle Orthod 2006; 76(2): 211-216.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0121-246X201200010000200014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>15. Thorstenson GA, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop 2002; 122(3): 295-305.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X201200010000200015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>16. Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F. Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracketarchwire combinations. Am J Orthod Dentofacial Orthop 2003; 124(4): 395-402.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0121-246X201200010000200016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>17. Thorstenson GA, Kusy RP. Comparison of resistance to sliding between different self-ligating brackets with secondorder angulation in the dry and saliva states. Am J Orthod Dentofacial Orthop 2002; 121(5): 472-482.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0121-246X201200010000200017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>18. Whitley JQ, Kusy RP. Influence of interbracket distances on the resistance to sliding of orthodontic appliances. Am J Orthod Dentofacial Orthop 2007; 132(3): 360-372.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0121-246X201200010000200018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>19. Kusy RP, Whitley JQ. Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots. I. The dry state. Am J Orthod Dentofacial Orthop 1990; 98(4): 300-312.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0121-246X201200010000200019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>20. Bortoly TG, Guerrero AP, Rached RN, Tanaka O, Guariza- Filho O, Rosa EA. Sliding resistance with esthetic ligatures: an in-vitro study. Am J Orthod Dentofacial Orthop 2008; 133(3): 340.e1-340.e7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0121-246X201200010000200020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>21. Chimenti C, Franchi L, Di Giuseppe MG, Lucci M. Friction of orthodontic elastomeric ligatures with different dimensions. Angle Orthod 2005; 75(3): 421-425.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0121-246X201200010000200021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>22. Thorstenson GA, Kusy RP. Resistance to sliding of selfligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states. Am J Orthod Dentofacial Orthop 2001; 120(4): 361-370.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0121-246X201200010000200022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>23. Plaza SP, Nieto M, Barrera JP, Trivi&ntilde;o AL, Valencia A. Comparaci&oacute;n de la resistencia al deslizamiento en brackets de autoligado y un bracket convencional. Rev Venez Ortod 2010; 27(1): 29-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0121-246X201200010000200023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>24. Fortini A, Lupoli M, Cacciafesta V. A new low-friction ligation system. J Clin Orthod 2005; 39(8): 464-470.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0121-246X201200010000200024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>25. Thomas S, Sherriff M, Birnie D. A comparative in vitro study of the frictional characteristics of two types of selfligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures. Eur J Orthod 1998; 20(5): 589-596.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0121-246X201200010000200025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>26. Orsi L, Giuntoli F, Gandini P. Dati sperimental e conforme cliniche sulla biomec&aacute;nica a bassa frizione. Bolletino di Informaci&oacute;n Leone 2008; 81: 4-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0121-246X201200010000200026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>27. Franchi L, Baccetti T, Camporesi M, Barbato E. Forces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures. Am J Orthod Dentofacial Orthop 2008; 133(1): 87-90.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0121-246X201200010000200027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>28. Tecco S, Festa F, Caputi S, Traini T, Di Iorio D, D'Attilio M. Friction of conventional and self-ligating brackets using a 10 bracket model. Angle Orthod 2005; 75(6): 1041-1045.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0121-246X201200010000200028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>29. Bednar JR, Gruendeman GW, Sandrik JL. A comparative study of frictional forces between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop 1991; 100(6): 513-522.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0121-246X201200010000200029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>30. Shivapuja PK, Berger J. A comparative study of conventional ligation and self-ligation bracket systems. Am J Orthod Dentofacial Orthop 1994; 106(5): 472-480.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0121-246X201200010000200030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>31. Khambay B, Millett D, McHugh S. Evaluation of methods of archwire ligation on frictional resistance. Eur J Orthod 2004; 26(3): 327-332.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0121-246X201200010000200031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>32. Taylor NG, Ison K. Frictional resistance between orthodontic brackets and archwires in the buccal segments. Angle Orthod 1996; 66(3): 215-222.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0121-246X201200010000200032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>33. Demicheli M, Migliorati M, Balboni C, Silvestrini Biavati A. Confronto tra differenti sistemi bracket/filo/legature misurazione in vitro dell'attrito su un'intera arcata. Mondo Ortod&oacute;ncico N 2006; 4: 273-280.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0121-246X201200010000200033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>34. Franchi L, Baccetti T, Camporesi M, Giuntini V. Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth. Am J Orthod Dentofacial Orthop 2009; 136(3): 316-317.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0121-246X201200010000200034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>   </font>    <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>CORRESPONDENCIA</b></font></p>  <font size="2" face="Verdana">    <p>Judith Patricia Barrera Chaparro    <br> Carrera 18 N.&deg; 80-94. Bogot&aacute; D. C.     <br> Fundaci&oacute;n Universitaria San Mart&iacute;n     <br> Facultad de Posgrados de Odontolog&iacute;a     <br> Posgrado de Ortodoncia     <br> Correo electr&oacute;nico: <a href="mailto:barrerajudith@gmail.com">barrerajudith@gmail.com</a></p> </font>      ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miles]]></surname>
<given-names><![CDATA[PG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Self-ligating vs. conventional twin brackets during en-masse space closure with sliding mechanics]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2007</year>
<volume>132</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>223-225</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Drescher]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bourauel]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Schumacher]]></surname>
<given-names><![CDATA[HA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Frictional forces between bracket and arch wire]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1989</year>
<volume>96</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>397-404</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kapila]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Angolkar]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
<name>
<surname><![CDATA[Duncanson]]></surname>
<given-names><![CDATA[MG Jr]]></given-names>
</name>
<name>
<surname><![CDATA[Nanda]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1990</year>
<volume>98</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>117-126</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dowling]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Jones]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Lagerstrom]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Sandham]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An investigation into the behavioural characteristics of orthodontic elastomeric modules]]></article-title>
<source><![CDATA[Br J Orthodm]]></source>
<year>1998</year>
<volume>25</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>197-202</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thorstenson]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of stainless steel inserts on the resistance to sliding of esthetic brackets with secondorder angulation in the dry and wet states]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2003</year>
<volume>73</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>167-175</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hain]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dhopatkar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rock]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of ligation method on friction in sliding mechanics]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2003</year>
<volume>123</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>416-242</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thorstenson]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2003</year>
<volume>73</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>418-430</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baccetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Camporesi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Defraia]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Barbato]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2009</year>
<volume>79</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>533-539</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Griffiths]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ireland]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to sliding with 3 types of elastomeric modules]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2005</year>
<volume>127</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>670-675</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hain]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dhopatkar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rock]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of different ligation methods on friction]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2006</year>
<volume>130</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>666-670</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tecco]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Di]]></surname>
<given-names><![CDATA[Iorio D]]></given-names>
</name>
<name>
<surname><![CDATA[Cordasco]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Verrocchi]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Festa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro investigation of the influence of self-ligating brackets, low-friction ligatures, and archwire on frictional resistance]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2007</year>
<volume>29</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>390-397</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camporesi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Baccetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Forces released by esthetic preadjusted appliances with low-friction and conventional elastomeric ligatures]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2007</year>
<volume>131</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>772-725</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gandini]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Orsi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bertoncini]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Massironi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro frictional forces generated by three different ligation methods]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2008</year>
<volume>78</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>917-921</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baccetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2006</year>
<volume>76</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>211-216</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thorstenson]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2002</year>
<volume>122</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>295-305</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cacciafesta]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Sfondrini]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Ricciardi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Scribante]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Klersy]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Auricchio]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracketarchwire combinations]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2003</year>
<volume>124</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>395-402</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thorstenson]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of resistance to sliding between different self-ligating brackets with secondorder angulation in the dry and saliva states]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2002</year>
<volume>121</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>472-482</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of interbracket distances on the resistance to sliding of orthodontic appliances]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2007</year>
<volume>132</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>360-372</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Whitley]]></surname>
<given-names><![CDATA[JQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots. I. The dry state]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1990</year>
<volume>98</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>300-312</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bortoly]]></surname>
<given-names><![CDATA[TG]]></given-names>
</name>
<name>
<surname><![CDATA[Guerrero]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Rached]]></surname>
<given-names><![CDATA[RN]]></given-names>
</name>
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Guariza-]]></surname>
<given-names><![CDATA[Filho O]]></given-names>
</name>
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sliding resistance with esthetic ligatures: an in-vitro study]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2008</year>
<volume>133</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>340.e1-340.e7</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chimenti]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Di]]></surname>
<given-names><![CDATA[Giuseppe MG]]></given-names>
</name>
<name>
<surname><![CDATA[Lucci]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Friction of orthodontic elastomeric ligatures with different dimensions]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2005</year>
<volume>75</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>421-425</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thorstenson]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kusy]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to sliding of selfligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2001</year>
<volume>120</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>361-370</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Plaza]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Nieto]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Barrera]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Triviño]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Valencia]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Comparación de la resistencia al deslizamiento en brackets de autoligado y un bracket convencional]]></article-title>
<source><![CDATA[Rev Venez Ortod]]></source>
<year>2010</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-34</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fortini]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lupoli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cacciafesta]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new low-friction ligation system]]></article-title>
<source><![CDATA[J Clin Orthod]]></source>
<year>2005</year>
<volume>39</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>464-470</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thomas]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sherriff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Birnie]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative in vitro study of the frictional characteristics of two types of selfligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>1998</year>
<volume>20</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>589-596</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orsi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Giuntoli]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gandini]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="it"><![CDATA[Dati sperimental e conforme cliniche sulla biomecánica a bassa frizione]]></article-title>
<source><![CDATA[Bolletino di Información Leone]]></source>
<year>2008</year>
<volume>81</volume>
<page-range>4-7</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Baccetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Camporesi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Barbato]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Forces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2008</year>
<volume>133</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>87-90</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tecco]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Festa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Caputi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Traini]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Di]]></surname>
<given-names><![CDATA[Iorio D]]></given-names>
</name>
<name>
<surname><![CDATA[D'Attilio]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Friction of conventional and self-ligating brackets using a 10 bracket model]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2005</year>
<volume>75</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1041-1045</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bednar]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Gruendeman]]></surname>
<given-names><![CDATA[GW]]></given-names>
</name>
<name>
<surname><![CDATA[Sandrik]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative study of frictional forces between orthodontic brackets and arch wires]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1991</year>
<volume>100</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>513-522</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shivapuja]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative study of conventional ligation and self-ligation bracket systems]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>1994</year>
<volume>106</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>472-480</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khambay]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Millett]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[McHugh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of methods of archwire ligation on frictional resistance]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2004</year>
<volume>26</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>327-332</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
<name>
<surname><![CDATA[Ison]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Frictional resistance between orthodontic brackets and archwires in the buccal segments]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>1996</year>
<volume>66</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>215-222</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Demicheli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Migliorati]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Balboni]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Silvestrini Biavati]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="it"><![CDATA[Confronto tra differenti sistemi bracket/filo/legature misurazione in vitro dell'attrito su un'intera arcata]]></article-title>
<source><![CDATA[Mondo Ortodóncico N]]></source>
<year>2006</year>
<volume>4</volume>
<page-range>273-280</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franchi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Baccetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Camporesi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Giuntini]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2009</year>
<volume>136</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>316-317</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
