<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2012000100005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Evaluación no lineal de dos postes diferentes]]></article-title>
<article-title xml:lang="en"><![CDATA[Nonlinear evaluation of two different posts]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lopera Builes]]></surname>
<given-names><![CDATA[Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Latorre Correa]]></surname>
<given-names><![CDATA[Federico]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Villarraga Ossa]]></surname>
<given-names><![CDATA[Junes Abdul]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad de Antioquia Facultad de Ingeniería Mecánica ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<volume>23</volume>
<numero>2</numero>
<fpage>240</fpage>
<lpage>255</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2012000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2012000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2012000100005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: los dientes tratados endodóncicamente que van a ser rehabilitados con coronas y que han perdido parte de su estructura dental, necesitan de un poste prefabricado o colado para que ayude a la retención de la restauración final y así el diente pueda recuperar la funcionalidad y la estética. La literatura reporta cuándo utilizar un poste colado o prefabricado, pero no es contundente cuál distribuye mejor los esfuerzos, cuál material o forma de poste es mejor y si el módulo de elasticidad tiene o no relación con la distribución de las cargas a lo largo del eje axial del diente. MÉTODOS: se hicieron dos modelos en SolidWorks de un incisivo central superior con todas sus estructuras de soporte, uno con un poste colado y otro con un poste prefabricado, además de una corona completamente cerámica. Mediante un análisis de elementos finitos se cargaron dichos dientes a 200, 400, 600 y 800 N para llevarlos hasta la plasticidad. RESULTADOS: a 200 y 400 N ambos postes mostraron diferente distribución de esfuerzos sin afectar la restauración o la raíz dental. CONCLUSIONES: a cargas masticatorias normales, ambos postes son predecibles para rehabilitar un diente que necesita de la incorporación de un poste.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction: endodontically treated teeth that will be restored with crowns and which have lost part of their dental structure need a cast post or a prefabricated post to improve final restoration retention and therefore to be able to regain their functionality and aesthetics. The literature suggests when to use a cast or prefabricated post, but it is not conclusive in terms of which one has a better stress distribution, which post material or shape is better, or whether their modulus of elasticity is related to load distribution along the tooth's axis. Methods: by using Solid Works, two models of a maxillary central incisor with all its supporting structures were made, one with a cast post and another one with a prefabricated post plus an all-ceramic crown. By means of finite element analysis both teeth were subjected to loads of 200, 400, 600 and 800 N up to reaching their plasticity. Results: at 200 and 400 N, both posts showed different stress distribution patterns without altering the restoration or the tooth's root. Conclusions: at normal masticatory loads, both posts are likely to restore a tooth that needs addition of a post.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[poste colado]]></kwd>
<kwd lng="es"><![CDATA[poste prefabricado]]></kwd>
<kwd lng="es"><![CDATA[distribución de los esfuerzos]]></kwd>
<kwd lng="es"><![CDATA[mótodo de elementos finitos]]></kwd>
<kwd lng="en"><![CDATA[cast post]]></kwd>
<kwd lng="en"><![CDATA[prefabricated post]]></kwd>
<kwd lng="en"><![CDATA[stress distribution]]></kwd>
<kwd lng="en"><![CDATA[finite elements method]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Evaluaci&oacute;n no lineal de dos postes diferentes<sup>1</sup></b></font></p>          <p>&nbsp;</p>             <p>&nbsp;</p>          <p><b> Patricia Lopera Builes<sup>2</sup>; Federico Latorre Correa<sup>3</sup>; Junes Abdul Villarraga Ossa<sup>4</sup> </b></p>      <p>&nbsp;</p>     <p><sup>1</sup> Art&iacute;culo derivado de una investigaci&oacute;n hecha por el Grupo de   investigaci&oacute;n Biomateriales en Odontolog&iacute;a, Facultad de Odontolog&iacute;a   y el Grupo de Dise&ntilde;o Mec&aacute;nico, Facultad de Ingenier&iacute;a Mec&aacute;nica,   Universidad de Antioquia    <br>      <sup>2</sup> Odont&oacute;loga, especialista en Odontolog&iacute;a Integral del Adulto con &eacute;nfasis   en Prostodoncia, Facultad de Odontolog&iacute;a, Universidad de Antioquia    ]]></body>
<body><![CDATA[<br>      <sup>3</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto con   &eacute;nfasis en Prostodoncia, profesor asociado, Facultad de Odontolog&iacute;a,   Universidad de Antioquia. Correo electr&oacute;nico: <a href="flatorre@une.net.co">flatorre@une.net.co</a>    <br>      <sup>4</sup> Ingeniero mec&aacute;nico, Universidad Nacional de Colombia, sede Medell&iacute;n,   mag&iacute;ster en Ingenier&iacute;a Mec&aacute;nica, Universidad Sim&oacute;n Bol&iacute;var, Caracas,   Venezuela. Profesor asociado, Facultad de Ingenier&iacute;a Mec&aacute;nica,   Universidad de Antioquia. Correo electr&oacute;nico: <a href="junes@udea.edu.co">junes@udea.edu.co</a>    <br> </p> <b>RECIBIDO: ABRIL 12/2011-APROBADO: ENERO 31/2012</b>     <p>&nbsp;</p>     <p>Lopera P, Latorre F, Villaraga JA. Evaluaci&oacute;n no lineal de dos postes diferentes. Rev Fac Odontol Univ Antioq 2012; 23(2): 240-255.</p>     <p>&nbsp;</p>       <hr noshade>      <p><b>RESUMEN</b></p>     <p><b>INTRODUCCI&Oacute;N:</b> los dientes tratados endod&oacute;ncicamente que van a ser rehabilitados con coronas y que han perdido parte de su   estructura dental, necesitan de un poste prefabricado o colado para que ayude a la retenci&oacute;n de la restauraci&oacute;n final y as&iacute; el diente pueda   recuperar la funcionalidad y la est&eacute;tica. La literatura reporta cu&aacute;ndo utilizar un poste colado o prefabricado, pero no es contundente cu&aacute;l   distribuye mejor los esfuerzos, cu&aacute;l material o forma de poste es mejor y si el m&oacute;dulo de elasticidad tiene o no relaci&oacute;n con la distribuci&oacute;n   de las cargas a lo largo del eje axial del diente.    <br>   <b>M&Eacute;TODOS:</b> se hicieron dos modelos en SolidWorks de un incisivo central superior con todas   sus estructuras de soporte, uno con un poste colado y otro con un poste prefabricado, adem&aacute;s de una corona completamente cer&aacute;mica.   Mediante un an&aacute;lisis de elementos finitos se cargaron dichos dientes a 200, 400, 600 y 800 N para llevarlos hasta la plasticidad.    <br>   <b>RESULTADOS:</b> a 200 y 400 N ambos postes mostraron diferente distribuci&oacute;n de esfuerzos sin afectar la restauraci&oacute;n o la ra&iacute;z dental.    ]]></body>
<body><![CDATA[<br>   <b>CONCLUSIONES:</b> a   cargas masticatorias normales, ambos postes son predecibles para rehabilitar un diente que necesita de la incorporaci&oacute;n de un poste.</p>      <p><b>Palabras clave:</b> poste colado, poste prefabricado, distribuci&oacute;n de los esfuerzos, m&oacute;todo de elementos finitos. </p> <hr noshade>       <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>     <p>La odontolog&iacute;a restauradora se ve enfrentada a diario al   problema de rehabilitar los dientes tratados endod&oacute;ncicamente   y debilitados estructuralmente en su porci&oacute;n   coronal y radicular. Un problema en discusi&oacute;n ha sido   el pron&oacute;stico de estos dientes que requieren elementos   intrarradiculares cuando no hay posibilidades de hacer   odontolog&iacute;a adhesiva, debido a la p&eacute;rdida de estructura   significativa y lograr proveer retenci&oacute;n a la restauraci&oacute;n,1   influenciado por una variedad de par&aacute;metros: el n&uacute;mero   de los dientes adyacentes, los contactos oclusales, la   posici&oacute;n del diente en el arco, el estado apical de la ra&iacute;z,   la degradaci&oacute;n del col&aacute;geno radicular, las relaciones   intermoleculares en la dentina radicular, la cantidad del   tejido duro perdido, el grosor de la pared de la dentina   coronal remanente, el tipo de restauraci&oacute;n definitiva, la   presencia de un m&iacute;nimo de dentina remanente de 1,5 a   2 mm para tener el efecto de f&eacute;rula y el tipo de poste y material del mu&ntilde;&oacute;n utilizados.<sup>1, 2</sup></p>     <p>Algunos estudios informan que los postes no refuerzan   estructuralmente la ra&iacute;z dental ni previenen futuras   fracturas, ya que esto depende en mayor porcentaje del   remanente dentinario y la resistencia del diente depende   del correcto manejo que se haga de los diversos procedimientos posendod&oacute;ncicos.<sup>3, 4</sup></p>     <p>La literatura reporta cu&aacute;ndo debe utilizarse un poste   colado, el cual es recomendado generalmente cuando   hay p&eacute;rdida de m&aacute;s del 50% de la estructura dentaria y   se necesitar&iacute;a un m&iacute;nimo de remanente dentinal de 2 mm   para poder lograr el efecto de f&eacute;rula y contrarrestar los   esfuerzos laterales, que generar&iacute;an inestabilidad del poste.   Igualmente reporta que en estructuras dentinales mayores   al 50% y con un m&iacute;nimo de remanente de 2 mm se podr&iacute;an indicar tambi&eacute;n los postes prefabricados.<sup>5, 6</sup></p>     <p>Aunque existe claridad sobre el papel, no hay estudios   concluyentes acerca de cu&aacute;l de los dos tipos de postes   distribuye mejor las fuerzas masticatorias a trav&eacute;s de la   ra&iacute;z para que la estructura dentaria reciba los esfuerzos   masticatorios de manera adecuada, sin afectar la estructura dental o poner en riesgo la futura restauraci&oacute;n.<sup>7, 8</sup></p>     <p>Estos estudios no clarifican cu&aacute;l ser&iacute;a el mejor material,   forma y propiedades mec&aacute;nicas de los diferentes postes<sup>9, 10</sup>   y existe controversia entre los reportes, ya que unos   presentan evidencia a favor de un poste r&iacute;gido y otros   sugieren que estos mismos ser&iacute;an catastr&oacute;ficos para la estructura dentaria.<sup>11</sup></p>     ]]></body>
<body><![CDATA[<p>Estudios <i>in vitro</i> en an&aacute;lisis de elementos finitos se   han hecho en 2D y 3D, pero no han logrado dar una   explicaci&oacute;n clara, debido a algunas limitaciones computacionales   y a que se han hecho lineales, lo que   no muestra la realidad completa del sistema y ante   cargas solamente est&aacute;ticas<sup>12</sup> y los estudios cl&iacute;nicos   no logran demostrar ni explicar la superioridad de un   sistema sobre otro, debido a las variables biol&oacute;gicas   inherentes a las diferencias en las personas y a no   poder evaluar c&oacute;mo se distribuyen los esfuerzos<sup>13, 14</sup> y   los estudios <i>in vitro</i> sometidos a cargas con m&aacute;quinas   Instron, muestran dientes sometidos a cargas que no   se dan normalmente en la cavidad oral y presentan una   realidad diferente, ya que generalmente el diente no est&aacute; restaurado completo.<sup>15, 16</sup></p>     <p>A pesar de la controversia, se encuentra un consenso de la   importancia de conservar el m&aacute;ximo de estructura dentaria para disminuir los riesgos de fractura de los dientes.<sup>17, 18</sup></p>     <p>El m&eacute;todo de elementos finitos (MEF) envuelve una   serie de procedimientos computacionales y es muy   utilizado en odontolog&iacute;a porque permite encontrar soluciones   simples a problemas complejos, dividiendo una   estructura en un n&uacute;mero limitado o finito de elementos   los cuales son conectados entre s&iacute; por nodos, que se   comportan individualmente ante determinadas cargas.   Por lo tanto el m&eacute;todo no toma la estructura como una   sola unidad sino como una estructura con m&uacute;ltiples   partes donde se pueden identificar desplazamientos,   deformaciones, esfuerzos y valores de resistencia a la   fractura de la estructura. El m&eacute;todo es &uacute;til para determinar   propiedades biomec&aacute;nicas en tejidos humanos que dif&iacute;cilmente ser&iacute;an mensurables <i>in vivo</i>.<sup>19</sup></p>     <p>Entre los elementos finitos hay modelos est&aacute;ticos   lineales donde se cumple una relaci&oacute;n directa entre   un esfuerzo y una deformaci&oacute;n y unos no lineales que   tienen en cuenta la no linealidad del material, grandes   desplazamientos del modelo o condiciones de contacto   deslizantes. Por ejemplo, en el ligamento periodontal,   los estudios no lineales son m&aacute;s veraces en cuanto   al comportamiento de este ya que un estudio lineal   mostrar&iacute;a una deformaci&oacute;n exagerada ante grandes cargas.<sup>20, 21</sup></p>     <p>Por todo lo anterior el an&aacute;lisis no lineal ha llegado a ser   cada vez m&aacute;s una poderosa herramienta de aproximaci&oacute;n   para el c&aacute;lculo de esfuerzos en modelos que involucren   alguna no linealidad; estos estudios demandan m&aacute;s tiempo   computacional y costos, por lo que son m&aacute;s escasos,   pero dan mayor certeza del comportamiento completo del modelo.<sup>21</sup></p>     <p>El prop&oacute;sito de esta investigaci&oacute;n fue evaluar el comportamiento   no lineal de dos postes a diferentes cargas a   trav&eacute;s de la simulaci&oacute;n mediante el an&aacute;lisis de elementos   finitos, para determinar si realmente hay una ventaja de uno de los sistemas de restauraci&oacute;n sobre el otro.</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>M&Eacute;TODOS</b></font></p>     <p>Se hicieron dos modelos en SolidWorks (Dassault syst&eacute;mes,   Suresnes, Francia), que representaran la estructura   dentaria de un incisivo central superior con sus tejidos de   soporte, uno con un poste prefabricado en fibra de vidrio,   Parapost (Coltene, Whaledent International, Altstatten,   Switzerland) y otro con un poste colado en metal base   (4all, Ivoclar Vivadent, Shaan, Liechtenstein) y una corona   completamente cer&aacute;mica (emax press, emax ceram Ivoclar Vivadent) (<a href="#f1">figura 1</a>).</p>     <p>Se hizo un modelo no lineal.<sup>21</sup> En los materiales de los   postes se utilizaron elementos tetra&eacute;dricos de orden   superior (diez nodos por elemento) con el fin de obtener   mejor aproximaci&oacute;n de la geometr&iacute;a de las partes (<a href="#f2">figura 2</a>).</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f1"><img src=/img/revistas/rfoua/v23n2/v23n2a05f1.jpg></a> </p>     <p align="center"><a name="f2"><img src=/img/revistas/rfoua/v23n2/v23n2a05f2.jpg></a> </p>     <p align="center"><a name="t1e"><img src=/img/revistas/rfoua/v23n2/v23n2a05t1e.jpg></a> </p>     <p>Las propiedades mec&aacute;nicas de los elementos que se   asumen como lineales en el modelo, se obtuvieron   de estudios previos reportados en la literatura.<sup>22-26</sup>   El modelo cont&oacute; con propiedades isotr&oacute;picas para la   cer&aacute;mica feldesp&aacute;tica, la cofia de disilicato de litio, el   mu&ntilde;&oacute;n en resina, la gutapercha, la dentina, el ligamento   periodontal y el cemento; como propiedades no lineales   de la estructura, se tomaron las de ambos postes ya   que la literatura no reporta valores no lineales para   las dem&aacute;s estructuras<sup>5, 27</sup> y propiedades ortotr&oacute;picas   tanto para el hueso cortical como para el esponjoso28 (<a href="#t2e">tabla 2</a>).</p>     <p>La carga aplicada a los modelos se hizo a 45&deg; y   uniformemente distribuida a lo largo de la superficie   palatina, las cargas fueron de 200 hasta 800 N con intervalos   de 200 N, con el objetivo de llevar el modelo a la deformaci&oacute;n pl&aacute;stica y ver en cu&aacute;l rango se llegaba a ella.</p>     <p>Para este prop&oacute;sito, se hizo el diagrama esfuerzodeformaci&oacute;n   (<a href="#f3">figura 3</a>), donde se observa la diferencia   entre los l&iacute;mites de fluencia del material colado en metal   y del material prefabricado en fibra de vidrio. Para la convergencia   del modelo se utiliz&oacute; una soluci&oacute;n adaptativa empleando el m&eacute;todo h, con el 98% de precisi&oacute;n.</p>     <p align="center"><a name="t2e"><img src=/img/revistas/rfoua/v23n2/v23n2a05t2e.jpg></a> </p>     <p align="center"><a name="f3"><img src=/img/revistas/rfoua/v23n2/v23n2a05f3.jpg></a> </p>     <p><font size="3" face="Verdana"><b>Geometr&iacute;a</b></font></p>     <p>Se model&oacute; la ra&iacute;z del incisivo central superior con un   mu&ntilde;&oacute;n de 2 mm de estructura coronal remanente llevando   un bisel de 1 mm en su periferia para obtener el efecto de   abrazadera (de f&eacute;rula) de acuerdo con la literatura, tanto en postes colados como prefabricados.</p>     ]]></body>
<body><![CDATA[<p>La ra&iacute;z se dise&ntilde;&oacute; de forma c&oacute;nica, con di&aacute;metro de 5 mm   para todos los modelos para no afectar los resultados   debido a la gran variabilidad que existe en la anatom&iacute;a y en las dimensiones radiculares de un individuo a otro.</p>     <p>Para el modelo del conducto radicular se tuvo en cuenta   que la amplitud del canal pulpar no superara un tercio de   la amplitud radicular en su parte m&aacute;s estrecha; teniendo   como m&iacute;nimo 1 mm de dentina sana a su alrededor, sobre todo en la regi&oacute;n del &aacute;pice.</p>     <p>Los 4 mm apicales del conducto radicular se modelaron   con las propiedades de la gutapercha (material de obturaci&oacute;n   para endodoncia) conservando as&iacute; la cantidad   m&iacute;nima de obturaci&oacute;n remanente que se describe en la   literatura para evitar la filtraci&oacute;n. Para el resto del conducto   radicular y su porci&oacute;n coronal se model&oacute; un poste con   los diferentes tipos de materiales que se van a estudiar.   El poste se model&oacute; con di&aacute;metro coronal de 1,6 mm y   apical de 1,1 mm, ajust&aacute;ndose a la anatom&iacute;a interna del canal radicular con su porci&oacute;n apical redondeada.</p>     <p>La configuraci&oacute;n del mu&ntilde;&oacute;n guard&oacute; las proporciones de   la preparaci&oacute;n para una corona completa en cer&aacute;mica   de un incisivo central superior izquierdo, la cual requiere   una reducci&oacute;n axial de 1,8 mm. Con esto se asegur&oacute; un   espacio adecuado para la modelaci&oacute;n de la corona en   cer&aacute;mica de la siguiente manera: el espesor de la porcelana   fue entre 1,5 y 1,8 mm, excepto en la porci&oacute;n incisal   que fue de 2,0 mm. Todos estos par&aacute;metros permiten que   la restauraci&oacute;n cumpla con los requisitos de est&eacute;tica y   espesor recomendados para la resistencia del material y as&iacute; evitar los sobrecontornos.<sup>28</sup></p>     <p>El ligamento periodontal se dise&ntilde;&oacute; teniendo en cuenta las   propiedades isotr&oacute;picas con un espesor en la periferia   de la ra&iacute;z de 0,2 mm y se ubic&oacute; a 1,5 mm de la uni&oacute;n cementoam&eacute;lica.<sup>28</sup></p>     <p>Para el dise&ntilde;o del hueso alveolar se incluy&oacute; el hueso   esponjoso que forma el interior del cuerpo maxilar y el hueso cortical que rodea tanto el maxilar como el alv&eacute;olo.</p>     <p>Se consideraron ambas estructuras con propiedades   ortotr&oacute;picas (materiales con diferentes caracter&iacute;sticas   en el eje x, y, z). La altura &oacute;sea fue de 18 mm desde la cresta alveolar hasta la porci&oacute;n basal maxilar.</p>     <p>El hueso cortical fue de 1 mm de espesor en la zona   perif&eacute;rica desde la regi&oacute;n basal y de 0,5 mm hacia la   regi&oacute;n interna del alv&eacute;olo. El diente tuvo una longitud total   de 23,6 mm, la corona midi&oacute; 10,8 y la ra&iacute;z 12,8 mm.   Teniendo en cuenta que la anatom&iacute;a de los seres humanos   es variable, se tomaron datos promedio, similares a otros estudios.<sup>29</sup></p>     <p>Para obtener el esfuerzo y el desplazamiento, mediante   el modelo se utilizaron las constantes el&aacute;sticas (modelo   el&aacute;stico de Young: propiedad de los materiales que equivale   a la pendiente de la curva de esfuerzo contra la deformaci&oacute;n   en el rango el&aacute;stico y la raz&oacute;n de Poisson que es una   constante el&aacute;stica de los materiales que indica la relaci&oacute;n   entre la deformaci&oacute;n axial y lateral) para cada uno de los elementos que se van a analizar.</p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>     <p>Al hacer el modelo matem&aacute;tico tridimensional de los dos   incisivos centrales superiores tratados endod&oacute;ncicamente   y restaurados con dos postes diferentes, se llev&oacute; a cabo la   simulaci&oacute;n en Solid Works (Dassault syst&eacute;mes, Suresnes,   Francia, 2009) y se obtuvieron los siguientes resultados:   los esfuerzos en el modelo que contiene el poste colado,   se concentraron principalmente en el poste y en la subestructura cer&aacute;mica como lo muestran las <a href="#f4">figura 4A y B</a>.</p>     <p>En la <a href="#f5">figura 5</a> se observan la distribuci&oacute;n de los esfuerzos   y la deformaci&oacute;n ante las diferentes cargas. En las   <a href="#f5">figura 5A y 5B</a>, los esfuerzos fueron de 200 y 400 N,   respectivamente, la concentraci&oacute;n de esfuerzos fue en   los mismos sitios indicados en la anterior figura (<a href="#f4">figura 4</a>).    Como no se excedi&oacute; el l&iacute;mite de fluencia, se present&oacute;   una deformaci&oacute;n el&aacute;stica del poste. Para las cargas de   600 y 800 N (<a href="#f5">figura 5C y D</a>), los esfuerzos siguieron   concentr&aacute;ndose en los mismos sitios, pero con una deformaci&oacute;n   pl&aacute;stica del poste porque se excedi&oacute; el l&iacute;mite de fluencia para el material.</p>     <p>En la <a href="#f6">figura 6</a> se observa la concentraci&oacute;n de esfuerzos y   la deformaci&oacute;n ante las diferentes cargas del poste prefabricado.   Se observa que los esfuerzos se concentraron   en la subestructura cer&aacute;mica y en el mu&ntilde;&oacute;n de resina,   el poste prefabricado present&oacute; una deformaci&oacute;n dentro   del l&iacute;mite el&aacute;stico, mientras que para la subestructura   cer&aacute;mica y la resina se present&oacute; una deformaci&oacute;n pl&aacute;stica ya que se excedi&oacute; su l&iacute;mite de fluencia.</p>     <p align="center"><a name="f4"><img src=/img/revistas/rfoua/v23n2/v23n2a05f4.jpg></a> </p>     <p align="center"><a name="f5"><img src=/img/revistas/rfoua/v23n2/v23n2a05f5.jpg></a> </p>     <p align="center"><a name="f6"><img src=/img/revistas/rfoua/v23n2/v23n2a05f6.jpg></a> </p>     <p>Los esfuerzos von Mises de los dos tipos de postes   utilizados en este estudio y que se sometieron a cuatro   esfuerzos, desde 200 N hasta 800 N, con diferencias   de 200 N entre cada uno y donde se evalu&oacute; el esfuerzo   en la ra&iacute;z, en el poste y en la cofia, se resumen en la <a href="#t3e">tabla 3</a> y en <a href="#f7">figura 7</a>.</p>     <p align="center"><a name="t3e"><img src=/img/revistas/rfoua/v23n2/v23n2a05t3e.jpg></a> </p>     <p align="center"><a name="f7"><img src=/img/revistas/rfoua/v23n2/v23n2a05f7.jpg></a> </p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>     <p>El an&aacute;lisis de elementos finitos ha sido utilizado en la   odontolog&iacute;a porque permite evaluar el comportamiento   mec&aacute;nico del diente y de las estructuras con que se   restaura. Al modelar un diente con todas sus estructuras   como se restaura normalmente, con un modelo   tridimensional y hacer un an&aacute;lisis no lineal, ofrece las   posibilidades de tener una evaluaci&oacute;n m&aacute;s valida y hacer mejor aporte a la cl&iacute;nica.</p>     <p>El an&aacute;lisis no lineal de elementos finitos aplicado en esta investigaci&oacute;n   mostr&oacute; que existen diferencias en la distribuci&oacute;n   de los esfuerzos en los dientes tratados endod&oacute;ncicamente   y rehabilitados con postes prefabricados (fibra de vidrio)   y colado (metal base), sin embargo cada uno de los modelos   por ser la geometr&iacute;a del poste y el material de estos distintos, debe evaluarse igualmente diferente.</p>     <p>En este estudio se encontr&oacute; que el diente cuando fue   sometido a cargas normales para la cavidad oral, de   200 y 400N, el comportamiento fue similar para ambos   modelos, indicando que el riesgo de fractura no se puede   considerar por la concentraci&oacute;n de esfuerzo mayor   o menor en el poste. Una caracter&iacute;stica importante en   la distribuci&oacute;n de esfuerzos de ambos modelos, simulada   en este estudio, es que cuando se aumentan los   esfuerzos, se incrementan en el ligamento periodontal,   el cual absorbe una cantidad de esfuerzo y minimiza   los efectos sobre el diente y sus estructuras, por lo   tanto estudios que no simulen el ligamento periodontal   y su comportamiento, tendr&aacute;n una variable de error significativo.</p>     <p>En este an&aacute;lisis se observ&oacute; que el material m&aacute;s r&iacute;gido   de cada modelo absorbe mayor fuerza, por lo tanto en   el modelo del poste colado, la cofia cer&aacute;mica absorbe   mayor fuerza, seguida del espigo del poste y de la ra&iacute;z.   En el poste de fibra de vidrio la cofia cer&aacute;mica absorbe   la mayor fuerza, seguido de la ra&iacute;z y por &uacute;ltimo el espigo   del poste de fibra de vidrio, quien recibe un esfuerzo   menor. En este estudio se encontr&oacute; que ante las cargas   masticatorias fisiol&oacute;gicas de 200 N y 400 N, los postes   con m&oacute;dulos de elasticidad similares al de la dentina,   tienen m&aacute;s bajas concentraciones de esfuerzos en los   mismos postes y los distribuyen de manera diferente que el poste m&aacute;s r&iacute;gido.</p>     <p>Este resultado no est&aacute; de acuerdo con varios estudios,   como el de Zarone y colaboradores en 2006, que eval&uacute;a   los patrones de la distribuci&oacute;n de los esfuerzos en un   diente sano comparado con dientes restaurados con   diferentes configuraciones de materiales y se enuncia   que los materiales utilizados para la restauraci&oacute;n deben   ser similares a los tejidos del diente para poder permitir   que todo el sistema restaurador imite el comportamiento   mec&aacute;nico del diente natural. Entre limitaciones de este   estudio, est&aacute; el ser lineal, lo que implica que faltan datos para poder tener una conclusi&oacute;n m&aacute;s real del sistema.<sup>30</sup></p>     <p>Pegoretti y colaboradores en 2002, a trav&eacute;s de un an&aacute;lisis   de elementos finitos en 2D, analizaron el comportamiento   mec&aacute;nico de un poste de fibra de vidrio compar&aacute;ndolo   con un poste de fibra de carbono y un poste colado en   oro, teniendo como control un modelo de diente natural.   Este estudio muestra favorabilidad hacia los postes de   fibra de vidrio; sin embargo, su estudio no es tridimensional,   es lineal y no se analiza el ligamento periodontal,   por lo que sus conclusiones pueden tener un margen de   error importante, ya que no se puede concluir que un poste   r&iacute;gido pueda tener implicaciones de fractura o de da&ntilde;o al   sistema con un an&aacute;lisis lineal y no considerando todas las variables.<sup>31</sup></p>     <p>Estudios, como los de Mikako y colaboradores en 2008 y   Lippo y colaboradores en 2004, reportan que los postes   con m&oacute;dulo de elasticidad similar al de la dentina, tienen   mejor comportamiento ante los esfuerzos y tienen la ventaja   de ser recuperables cuando se fracturan, ya que los   patrones de fractura del diente son menos catastr&oacute;ficos   que con los postes de mayor rigidez.<sup>32, 33</sup> Seefeld y colaboradores   en 2005 sugieren que la utilizaci&oacute;n de postes   con propiedades biomec&aacute;nicas similares al de la dentina,   podr&iacute;an ser ventajoso, por reducir el riesgo de fracturas del   diente;<sup>27</sup> igualmente Aquaviva y colaboradores en 2002,   en una revisi&oacute;n de literatura, sugieren la utilizaci&oacute;n de un   poste de bajo m&oacute;dulo de elasticidad para mayor adhesi&oacute;n   y menor absorci&oacute;n de esfuerzos a la estructura dentaria y mayor protecci&oacute;n ante las cargas masticatorias.<sup>34</sup></p>     <p>En otros estudios, se encuentran similitudes con el nuestro,   como el de Naumman y colaboradores en 2007, que   investig&oacute; el impacto de un material r&iacute;gido (poste de titanio)   comparado con uno m&aacute;s &quot;flexible&quot; (poste de fibra de vidrio)   y se encontr&oacute; que al utilizar un poste con un m&oacute;dulo   de elasticidad menor o cercano al m&oacute;dulo de la dentina,   no implicaba mejor comportamiento para el sistema, y el   concepto ser&iacute;a debatible. El estudio plantea que cuando un   diente con diferentes componentes es sometido a cargas,   el componente r&iacute;gido tiene la capacidad de resistir grandes esfuerzos sin distorsi&oacute;n.<sup>35</sup></p>     ]]></body>
<body><![CDATA[<p>Sorrentino y colaboradores en 2006 hicieron un estudio con   elementos finitos que evalu&oacute; la distribuci&oacute;n de los esfuerzos   en todo el sistema conformado por el poste, el mu&ntilde;&oacute;n y la   corona y el estudio se&ntilde;ala la importancia de un material   con un m&oacute;dulo m&aacute;s alto para el material de la corona,   lo que permite que cubra todo el sistema y se eviten mayores   esfuerzos en todo el diente. Esto lo muestra nuestro   estudio tambi&eacute;n, en el que los mayores esfuerzos se dan en la cer&aacute;mica inicialmente.<sup>36</sup></p>     <p>Otro estudio <i>in vitro</i> de Qing y colaboradores en 2007   investig&oacute; la resistencia a la fractura de dientes anteriores   tratados endod&oacute;ncicamente y restaurados con poste de   fibra de vidrio y de zirconio, en el que se tom&oacute; como grupo control los dientes restaurados con postes colados.</p>     <p>Se mostr&oacute; diferencias en la resistencia a la fractura en los   dos grupos evaluados, planteando que los postes r&iacute;gidos   podr&iacute;an mejorar la resistencia a la deflexi&oacute;n. Confirman   tambi&eacute;n que el poste y mu&ntilde;&oacute;n colado fueron m&aacute;s resistentes   a las fuerzas de deflexi&oacute;n y que mostraban fallas con   carga muy altas, por lo tanto aclaran que estos resultados   no son prueba para decir que no es conveniente el uso cl&iacute;nico de los postes.<sup>37</sup></p>     <p>Schmitter y colaboradores en 2010, en un interesante   estudio, ya que combina an&aacute;lisis <i>in vitro</i> con modelaci&oacute;n   en elementos finitos, concluye que la parte m&aacute;s importante   es la uni&oacute;n de la corona al mu&ntilde;&oacute;n para proteger el   sistema y que el efecto del poste de vidrio no dar&iacute;a ninguna ventaja al sistema.<sup>38</sup></p>     <p>En el estudio m&aacute;s similar al nuestro, en planteamiento del   mismo problema, en metodolog&iacute;a, en ser tridimensional   y hacer an&aacute;lisis no lineal, Dejak y colaboradores en 2011   encuentran resultados y conclusiones muy similares,   pues bajo cargas fisiol&oacute;gicas, los postes hechos en metal   o en fibra de vidrio, no comprometen el da&ntilde;o al diente y los   postes colados transmiten menos esfuerzo a la dentina,   debido a sus propiedades mec&aacute;nicas de un m&oacute;dulo de elasticidad m&aacute;s alto.<sup>29</sup></p>     <p>La confrontaci&oacute;n de los estudios anteriores, a favor y en   contra, muestra que los estudios previos no han resuelto   la controversia de cu&aacute;l sistema de postes da mayor resistencia y longevidad a los dientes.</p>     <p>De los resultados de esta investigaci&oacute;n, no se concluye   que alg&uacute;n tipo de poste sea mejor que el otro, ya que los   esfuerzos ante las cargas normales sobre las ra&iacute;ces, es   decir a 200 y 400 N, se comportan de manera similar, y   aun ante esfuerzos que pueden ser catastr&oacute;ficos, como   ser&iacute;a las concentraciones a 600 y 800 N, no hay diferencias   tan marcadas en las ra&iacute;ces. La respuesta a por qu&eacute; se   fractura alguno de los elementos, poste, ra&iacute;z, mu&ntilde;&oacute;n, ante   esfuerzos que dif&iacute;cilmente se dan en boca, como ser&iacute;a a   600 y 800 N, se da en las propiedades mec&aacute;nicas mismas   de cada material o tejido, pero no porque un material lleve a mayor concentraci&oacute;n de esfuerzos sobre las ra&iacute;ces.</p>     <p>En el presente estudio, los esfuerzos se concentraron   de manera diferente en el poste, en la ra&iacute;z y en la cofia   cer&aacute;mica en ambos tipos de postes, coincidiendo con el estudio de Dejak y colaboradores.<sup>29</sup></p>     <p>En este estudio se obvi&oacute; el cemento debido a que se   requer&iacute;a un n&uacute;mero alto de elementos, lo que lleva al   aumento en tiempo y costo computacional, y se ha   evidenciado que, debido a sus propiedades mec&aacute;nicas   similares a la dentina, esto no ser&iacute;a relevante como   parte de la estructura, ya que se verific&oacute; que este no   recibe las cargas aplicadas sino que las transmite directamente al poste y a la ra&iacute;z.<sup>39</sup></p>     <p>En el estudio hecho, cuando se incrementaron los esfuerzos,   los resultados mostraron que el poste colado, la cofia   cer&aacute;mica y el espigo reciben gran esfuerzo observ&aacute;ndose   una deformaci&oacute;n pl&aacute;stica del espigo del poste colado a   600 MPa, mientras que el poste prefabricado exhibe   mayores deformaciones el&aacute;sticas. Esto demostrar&iacute;a las   diferencias en estudios cl&iacute;nicos o en estudios <i>in vitro</i>, en   los que con el poste colado las fracturas se observan   en el espigo y hacia cervical mientras que en el poste   prefabricado se observan en el mu&ntilde;&oacute;n o en cervical y   casi nunca en el espigo. Estos hallazgos tambi&eacute;n son   corroborados por Varvara y colaboradores en 2007 en   un estudio <i>in vitro</i>, hecho para evaluar la resistencia a   la fractura de dientes tratados endod&oacute;ncicamente con   diferentes alturas de dentina residual, concluyendo   que ante altas cargas, los postes con alto m&oacute;dulo de   elasticidad resistieron m&aacute;s las cargas que los postes   m&aacute;s flexibles, pero estos &uacute;ltimos presentaron fallas m&aacute;s   favorables que los primeros. Sin embargo, los autores   concluyen que estas cargas con fallas catastr&oacute;ficas de   los colados, se dan a fuerzas que generalmente no se   presentan en la cavidad oral, coherente con lo encontrado en nuestro estudio.<sup>8</sup></p>     ]]></body>
<body><![CDATA[<p>En este estudio, se muestra c&oacute;mo en las dos ra&iacute;ces los   esfuerzos son muy similares, lo que permite explicar   que ante ra&iacute;ces con una buena estructura, los riesgos de fractura no se dan con ninguno de los dos sistemas. </p>     <p>En las especificaciones de este estudio, es importante   mencionar que fue con carga est&aacute;tica, no lineal,   tridimensional, sometido a fuerzas fisiol&oacute;gicas y no   fisiol&oacute;gicas. Se sugiere continuar con estudios con   carga din&aacute;mica que simulen totalmente la realidad   cl&iacute;nica, para complementar los estudios cl&iacute;nicos sobre esta &aacute;rea.</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>     <p>En las especificaciones de este estudio se puede concluir:</p> <ol>       <li>    <p> Cuando las fuerzas masticatorias est&aacute;n en rangos     considerados fisiol&oacute;gicos (200 a 400 N), y la ra&iacute;z     cumple las especificaciones del espacio m&iacute;nimo para     los postes, sin debilitar su estructura dentaria, ambos     postes pueden ser predecibles para rehabilitar un diente   tratado endod&oacute;ncicamente.</p></li>       <li>    <p> No se puede determinar que un sistema sea mejor     que el otro, ya que su comportamiento es totalmente   diferente.</p></li>       <li>    ]]></body>
<body><![CDATA[<p> Conocer c&oacute;mo se presentan las concentraciones de     los esfuerzos a diferentes cargas, en forma diferente     en cada modelo, permite al cl&iacute;nico tomar la decisi&oacute;n   adecuada seg&uacute;n la elecci&oacute;n de sistema que se use.</p></li>     </ol>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>     <!-- ref --><p>1. Schwartz R. Post placement and restoration of endodontically   treated teeth: A literature review. J Endod 2004; 30(5): 289-301.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X201200010000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>2. Naumann M, Kiessling S. Treatment concepts for restoration   of endodontically treated teeth: A nationwide survey of dentist in Germany. J Prosthet Dent 2006; 96(5): 332-338.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X201200010000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>3. Mikako H, Yutaka T, Satoshi I. Fracture resistance of pulpless   teeth restored with post-cores and crowns. Dent Mater 2006; 22: 477-485.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X201200010000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>4. Plotino G, Grande N. Flexural properties of endodontic   posts and human root dentin. Dent Mater 2007; 23(9): 1129-1135.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201200010000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>5. Torbjorner A. A literature review on the prosthetic treatment   of structurally compromised teeth. Intern J Prostho 2004; 17(3): 369-372.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X201200010000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>6. Cheung W. A review of the management of endodontically   treated teeth. Post, core and the final restoration. Am Dent Assoc 2005; 136 (5): 611-619.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X201200010000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>7. Fernandez A, Shetty S, Countinho I. Factors determining   post selection: a literature review. J Prosthet Dent 2003; 90: 556-562.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X201200010000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>8. Varvara G, Perinneti G, Dilorio D, Murmura G, Caputi S. In   vitro evaluation of fracture resistance and failure mode of   internally restored endodontically treated maxillary incisors   with differing heights of residual dentin. J Prosthet Dent 2007; 98: 365-332.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0121-246X201200010000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>9. B&euml;gum A. An in vitro study evaluating the effect of ferrule   length on fracture resistance of endodontically treated with   fiber-reinforced and zirconia dowel systems. J Prosthet Dent 2004; 92: 155-162.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0121-246X201200010000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>10. Barjau A, Sancho J, Forner L, Rodriguez P, P&eacute;rez A, S&aacute;nchez   F. Influence of prefabricated post material on restored   teeth: Fracture strength and stress distribution. Oper Dent 2006; 31(1): 47-54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0121-246X201200010000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>11. Sorrentino R, Aversa R, Ferro V, Auriemma T, Zarone F,   Ferrari M et al. Three dimensional finite elements analysis   of strain and stress distribution in endodontically treated   maxillary central incisors restored with different post, core and crown materials. Dent Mater 2007; 23: 983-993.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0121-246X201200010000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>12. Sahafi A, Peutzfeld A, Asmussen E. Retention and failure   morphology of prefabricated posts. Int J Prosthodont 2004; 17(3): 307-312.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0121-246X201200010000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>13. Boderau F, Besone E, Baina L. Estudio comparativo de la   adaptaci&oacute;n de tres sistemas de postes. Rev Intern Prot Estom 2004; 6(3): 183-189.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0121-246X201200010000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>14. Lippo V, Lassila J, Tanner J. Flexural properties of fiber reinforced root canal posts. Dent Mater 2004; 20(1): 29-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S0121-246X201200010000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>15. Kremeier K, Fasen L, Klaiber B. Influence of endodontic   post type and luting material on push out bond strength to dentin in vivo. Dent Mater 2008; 24: 660-666.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000135&pid=S0121-246X201200010000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>16. Hew Y, Purton G, Love M. Evaluation of prefabricated root canals posts. J Oral Rehab 2001; 28: 207-211.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000137&pid=S0121-246X201200010000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>17. Fitzpatrick B. Evidence-based dentistry-it subdivided:   accepted truths, once divided, may lack validity. Intern J Prosth 2008; 21(4): 358-363.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S0121-246X201200010000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>18. Wiskott A, Meyer M, Perriard J. Rotational fatigue-resistance   of seven post types anchored on natural teeth. Den Mater 2007; 23: 1412-1419.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000141&pid=S0121-246X201200010000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>19. Reddy JN. Boundary element method. En: Reddy JN. An   introduction to the finite element method. 3.&ordf; ed. New York: McGraw-Hill; 2005. p. 442-443.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000143&pid=S0121-246X201200010000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>20. Geng PJ, Tan KBC, Liu GR. Application of finite element   analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001; 85(6): 585-598.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000145&pid=S0121-246X201200010000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>21. Wakabayashi N, Ona M, Suzuki T, Igarashi Y. Nonlinear   finite element analysis: advances and challenges in dental applications. J Dent 2008; 36(7): 463-471.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000147&pid=S0121-246X201200010000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>22. Toparli M. Stress analysis in a post restored tooth utilizing the finite elements method. J Oral Rehab 2003; 30: 470-476.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000149&pid=S0121-246X201200010000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>23. Ivoclar Vivadent. Ficha t&eacute;cnica IPS e.max Press &#91;Internet&#93;   &#91;fecha de acceso octubre 16 de 2011&#93;; URL disponible   en <a href="http:// www.ivoclarvivadent.com/es/todos/productos/ ceramica-sin-metal/ips-emax-system-tecnico-dental/ipse_ max-press" target="_blank">http:// www.ivoclarvivadent.com/es/todos/productos/   ceramica-sin-metal/ips-emax-system-tecnico-dental/ipse_ max-press</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000151&pid=S0121-246X201200010000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>24. Asmussen E, Peutzfeldt A, Sahafi A. Finite element analysis   of stress in endodontically treated, dowel-restored teeth. J Prosthet Dent 2005; 94(4): 321-329.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000153&pid=S0121-246X201200010000500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>25. Maceri F, Martignoni M, Vairo G. Mechanical behavior   of endodontic restoration with multiple prefabricated   posts: a finite elements approach. J Biomech 2006; 40(11): 2386-2398.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000155&pid=S0121-246X201200010000500025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>26. 3M ESPE. Ficha t&eacute;cnica Rely XTM Unicem. Aplicap TM/   Maxicap TM &#91;internet&#93;. &#91;fecha de acceso octubre 16 de   2011&#93;; URL disponible en: <a href="http://www.ddsltdlab.com/pdf/ CementationTechniques.pdf" target="_blank">http://www.ddsltdlab.com/pdf/ CementationTechniques.pdf</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000157&pid=S0121-246X201200010000500026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>27. Seefeld F, Wenz HJ, Ludwig K, Kern M. Resistance to   fracture and structural characteristics of different fiber reinforced post systems. Dent Mater 2007; 23(3): 265-71.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000159&pid=S0121-246X201200010000500027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>28. Heoung-Jae Chun, Ha-Shik Shin, Chong-Hyun Han, Soo-   Hong Lee. Influence of implant abutment type on stress   distribution in bone under various loading conditions using   finite element analysis. Int J Oral Maxillofac Implants 2006; 21: 195-202.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000161&pid=S0121-246X201200010000500028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>29. Dejak B, Andrzej M. Finite element analysis of strength and   adhesion of cast posts compared to glass fiber-reinforced   composite resin posts in anterior teeth. J Prosthet Dent 2011; 105: 115-126.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000163&pid=S0121-246X201200010000500029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>30. Zarone F, Sorrentino R, Apicella D, Valentino B, Ferrari M,   Aversa R et al. Evaluation of the biomechanical behaviour of   maxillary central incisors restored by means of endocrowns   compared to a natural tooth: a 3D static linear finite element analysis. Dent Mater 2006; 22: 1035-1044.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000165&pid=S0121-246X201200010000500030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>31. Pegoretti A, Fambri L, Zappini G, Biancheti M. Finite   element analysis of a glass fibre reinforced composite endodontic post. Biomaterials 2002; 23: 2667-2682.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000167&pid=S0121-246X201200010000500031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>32. Mikako H, Atsushi S, Yutaka T, Satoshi I. Static and fatigue   fracture resistances of pulpless teeth restored with postcores. Dent Mater 2008; 24(9): 1178-1186.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000169&pid=S0121-246X201200010000500032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>33. Lippo V, Lassila J, Tanner J. Flexural properties of fiber reinforced root canal posts. Dent Mater 2004; 20(1): 29-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000171&pid=S0121-246X201200010000500033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>34. Aquaviva S, Fernandes, Sharat S. Factores que influyen en   la resistencia a la fractura de los dientes reconstruidos con   postes y mu&ntilde;ones: Revisi&oacute;n. Rev Intern Prot Estom 2002; 4(1): 23-31.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000173&pid=S0121-246X201200010000500034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>35. Naumman M, Preuss A, Frankenberger R. Reinforcement   effect of adhesively luted fiber reinforced composite versus titanium post. Dent Mater 2007; 23(2):138-144.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000175&pid=S0121-246X201200010000500035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>36. Sorrentino R, Aversa R, Ferro V, Auriemma T, Zarone F,   Ferrari M et al. Three-dimensional finite element analysis   of strain and stress distributions in endodontically treated   maxillary central incisors restored with different post, core, and crown materials. Dent Mater 2006; 23(8): 983-993.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000177&pid=S0121-246X201200010000500036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>37. Qing H, Zhu Z, Chao Y, Zhang WQ. In vitro evaluation of   the fracture resistance of anterior endodontically treated   teeth restored with glass fiber and zircon posts. J Prosthet Dent 2007; 97(2):93-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000179&pid=S0121-246X201200010000500037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>38. Schmitter M, Rammelsberg P, Lenz J, Scheuber S,   Schweizerhof K, Rues S. Teeth restored using fiberreinforced   posts: In vitro fracture tests and finite element analysis. Acta Biomaterialia 2010; 6: 3747-3754.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000181&pid=S0121-246X201200010000500038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>39. Orozco M, Villarraga J, Latorre F, Escobar JC. Influencia   de los materiales de cementaci&oacute;n en la distribuci&oacute;n de los   esfuerzos en un incisivo central superior rehabilitado con   poste. An&aacute;lisis de elementos finitos. Rev Fac Odontol Univ Antioq 2011; 23(1): 56-75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000183&pid=S0121-246X201200010000500039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>CORRESPONDENCIA</b></font></p>     <p>Federico Latorre Correa    <br>   Facultad de Odontolog&iacute;a, Universidad de Antioquia     <br>   Calle 64 N.o 52-59    <br>   Medell&iacute;n, Colombia     <br>   Correo electr&oacute;nico:    <a href="flatorre@une.net.co">flatorre@une.net.co</a> </p>  </font>       ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schwartz]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Post placement and restoration of endodontically treated teeth: A literature review]]></article-title>
<source><![CDATA[J Endod]]></source>
<year>2004</year>
<volume>30</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>289-301</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Naumann]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kiessling]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment concepts for restoration of endodontically treated teeth: A nationwide survey of dentist in Germany]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2006</year>
<volume>96</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>332-338</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mikako]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Yutaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Satoshi]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fracture resistance of pulpless teeth restored with post-cores and crowns]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2006</year>
<volume>22</volume>
<page-range>477-485</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flexural properties of endodontic posts and human root dentin]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2007</year>
<volume>23</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1129-1135</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torbjorner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A literature review on the prosthetic treatment of structurally compromised teeth]]></article-title>
<source><![CDATA[Intern J Prostho]]></source>
<year>2004</year>
<volume>17</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>369-372</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Post, core and the final restoration]]></article-title>
<source><![CDATA[Am Dent Assoc]]></source>
<year>2005</year>
<volume>136</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>611-619</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernandez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Shetty]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Countinho]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Factors determining post selection: a literature review]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2003</year>
<volume>90</volume>
<page-range>556-562</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Varvara]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Perinneti]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Dilorio]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Murmura]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Caputi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro evaluation of fracture resistance and failure mode of internally restored endodontically treated maxillary incisors with differing heights of residual dentin]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2007</year>
<volume>98</volume>
<page-range>365-332</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bëgum]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro study evaluating the effect of ferrule length on fracture resistance of endodontically treated with fiber-reinforced and zirconia dowel systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2004</year>
<volume>92</volume>
<page-range>155-162</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barjau]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sancho]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Forner]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Rodriguez]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of prefabricated post material on restored teeth: Fracture strength and stress distribution]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2006</year>
<volume>31</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>47-54</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sorrentino]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Aversa]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ferro]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Auriemma]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zarone]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Three dimensional finite elements analysis of strain and stress distribution in endodontically treated maxillary central incisors restored with different post, core and crown materials]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2007</year>
<volume>23</volume>
<page-range>983-993</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sahafi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Peutzfeld]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Asmussen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Retention and failure morphology of prefabricated posts]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2004</year>
<volume>17</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>307-312</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boderau]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Besone]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Baina]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio comparativo de la adaptación de tres sistemas de postes]]></article-title>
<source><![CDATA[Rev Intern Prot Estom]]></source>
<year>2004</year>
<volume>6</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>183-189</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lippo]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Lassila]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tanner]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flexural properties of fiber reinforced root canal posts]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2004</year>
<volume>20</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-36</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kremeier]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Fasen]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Klaiber]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of endodontic post type and luting material on push out bond strength to dentin in vivo]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2008</year>
<volume>24</volume>
<page-range>660-666</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hew]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Purton]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Love]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of prefabricated root canals posts]]></article-title>
<source><![CDATA[J Oral Rehab]]></source>
<year>2001</year>
<volume>28</volume>
<page-range>207-211</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fitzpatrick]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evidence-based dentistry-it subdivided: accepted truths, once divided, may lack validity]]></article-title>
<source><![CDATA[Intern J Prosth]]></source>
<year>2008</year>
<volume>21</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>358-363</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wiskott]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Meyer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Perriard]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rotational fatigue-resistance of seven post types anchored on natural teeth]]></article-title>
<source><![CDATA[Den Mater]]></source>
<year>2007</year>
<volume>23</volume>
<page-range>1412-1419</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reddy]]></surname>
<given-names><![CDATA[JN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Boundary element method]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Reddy]]></surname>
<given-names><![CDATA[JN]]></given-names>
</name>
</person-group>
<source><![CDATA[An introduction to the finite element method]]></source>
<year>2005</year>
<edition>3</edition>
<page-range>442-443</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Geng]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[KBC]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of finite element analysis in implant dentistry: A review of the literature]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2001</year>
<volume>85</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>585-598</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wakabayashi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Ona]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Suzuki]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Igarashi]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nonlinear finite element analysis: advances and challenges in dental applications]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2008</year>
<volume>36</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>463-471</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Toparli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stress analysis in a post restored tooth utilizing the finite elements method]]></article-title>
<source><![CDATA[J Oral Rehab]]></source>
<year>2003</year>
<volume>30</volume>
<page-range>470-476</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="">
<source><![CDATA[Ivoclar Vivadent]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Asmussen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Peutzfeldt]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sahafi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of stress in endodontically treated, dowel-restored teeth]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2005</year>
<volume>94</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>321-329</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maceri]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Martignoni]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Vairo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical behavior of endodontic restoration with multiple prefabricated posts: a finite elements approach]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>2006</year>
<volume>40</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2386-2398</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="">
<source><![CDATA[3M ESPE. Ficha técnica Rely XTM Unicem. Aplicap TM/ Maxicap TM]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Seefeld]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Wenz]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Ludwig]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Kern]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to fracture and structural characteristics of different fiber reinforced post systems]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2007</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>265-71</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heoung-Jae]]></surname>
<given-names><![CDATA[Chun]]></given-names>
</name>
<name>
<surname><![CDATA[Ha-Shik]]></surname>
<given-names><![CDATA[Shin]]></given-names>
</name>
<name>
<surname><![CDATA[Chong-Hyun]]></surname>
<given-names><![CDATA[Han]]></given-names>
</name>
<name>
<surname><![CDATA[Soo-]]></surname>
<given-names><![CDATA[Hong]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2006</year>
<volume>21</volume>
<page-range>195-202</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dejak]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Andrzej]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of strength and adhesion of cast posts compared to glass fiber-reinforced composite resin posts in anterior teeth]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2011</year>
<volume>105</volume>
<page-range>115-126</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zarone]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Sorrentino]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Apicella]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Valentino]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Aversa]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of the biomechanical behaviour of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite element analysis]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2006</year>
<volume>22</volume>
<page-range>1035-1044</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pegoretti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fambri]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Zappini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Biancheti]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of a glass fibre reinforced composite endodontic post]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2002</year>
<volume>23</volume>
<page-range>2667-2682</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mikako]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Atsushi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Yutaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Satoshi]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Static and fatigue fracture resistances of pulpless teeth restored with postcores]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2008</year>
<volume>24</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1178-1186</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lippo]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Lassila]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tanner]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flexural properties of fiber reinforced root canal posts]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2004</year>
<volume>20</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-36</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aquaviva]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fernandes,]]></surname>
<given-names><![CDATA[Sharat]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Factores que influyen en la resistencia a la fractura de los dientes reconstruidos con postes y muñones: Revisión]]></article-title>
<source><![CDATA[Rev Intern Prot Estom]]></source>
<year>2002</year>
<volume>4</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>23-31</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Naumman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Preuss]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Frankenberger]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reinforcement effect of adhesively luted fiber reinforced composite versus titanium post]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2007</year>
<volume>23</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>138-144</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sorrentino]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Aversa]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ferro]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Auriemma]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zarone]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Three-dimensional finite element analysis of strain and stress distributions in endodontically treated maxillary central incisors restored with different post, core, and crown materials]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2006</year>
<volume>23</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>983-993</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Qing]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Chao]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[WQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro evaluation of the fracture resistance of anterior endodontically treated teeth restored with glass fiber and zircon posts]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2007</year>
<volume>97</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>93-8</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schmitter]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rammelsberg]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lenz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Scheuber]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Schweizerhof]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Rues]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Teeth restored using fiberreinforced posts: In vitro fracture tests and finite element analysis]]></article-title>
<source><![CDATA[Acta Biomaterialia]]></source>
<year>2010</year>
<volume>6</volume>
<page-range>3747-3754</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orozco]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Villarraga]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Latorre]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Escobar]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Influencia de los materiales de cementación en la distribución de los esfuerzos en un incisivo central superior rehabilitado con poste. Análisis de elementos finitos]]></article-title>
<source><![CDATA[Rev Fac Odontol Univ Antioq]]></source>
<year>2011</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>56-75</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>