<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2013000200005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[REPRODUCIBILIDAD EN LA UBICACIÓN DE PUNTOS CEFALOMÉTRICOS DE TEJIDOS BLANDOS EN RADIOGRAFÍAS CONVENCIONALES Y DIGITALES DIRECTAS]]></article-title>
<article-title xml:lang="en"><![CDATA[REPRODUCIBILITY OF SOFT TISSUE CEPHALOMETRIC LANDMARK IDENTIFICATION BY CONVENTIONAL AND DIGITAL DIRECT RADIOGRAPHY]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bonilla Londoño]]></surname>
<given-names><![CDATA[Margarita María]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Barrera Chaparro]]></surname>
<given-names><![CDATA[Judith Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Arroyave Godoy]]></surname>
<given-names><![CDATA[Angela Ptricia]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Díaz Roa]]></surname>
<given-names><![CDATA[Mónica Eliana]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Universitaria San Martín  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2013</year>
</pub-date>
<volume>25</volume>
<numero>1</numero>
<fpage>76</fpage>
<lpage>91</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2013000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2013000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2013000200005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: es escasa la información sobre la reproducibilidad de puntos cefalométricos de tejidos blandos, el propósito de este estudio fue evaluar la reproducibilidad y precisión de la ubicación de los puntos cefalométricos de tejidos blandos en una radiografía digital directa y una radiografía convencional. MÉTODOS: se utilizaron 11 pares de radiografías convencionales y radiografías digitales directas las cuales se introdujeron en el programa Cephapoint. Se ubicaron 10 puntos cefalométricos en un plano cartesiano (X y Y) en las imágenes convencional y digital. Las medidas fueron hechas dos veces por 3 operadores con intervalo de 1 semana. Se halló el promedio de error interobservador para medir la reproducibilidad de cada punto y el error intraobservador para determinar la precisión. RESULTADOS: el error interobservador en la ubicación de puntos cefalométricos en tejidos blandos fue menor a 1 mm para la mayoría de los puntos en ambas imágenes, excepto para mentón y pogonion, sin diferencias estadísticamente significativas. Se encontraron diferencias estadísticamente significativas entre las varianzas en el eje X, con menor variabilidad para la radiografía digital en los puntos labrale superior (p = 0,043), subnasal (p = 0, 013), columnella (p = 0,038), stomion superior (p = 0,029) y stomion inferior (p = 0,015). En el eje y no se presentaron diferencias estadísticamente significativas entre los dos métodos. La evaluación de la reproducibilidad intraobservador mostró coeficiente de correlación intraclase (CCI) excelente (0,935) en ambos métodos. CONCLUSIÓN: de acuerdo con los hallazgos de este estudio las radiografías y los métodos evaluados brindan igual validez diagnóstica.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: there is little information on the reproducibility of soft tissue cephalometric points; the purpose of this study was then to evaluate the reproducibility and accuracy of soft tissue cephalometric landmark identification in direct digital radiography and conventional radiography. METHODS: 11 pairs of conventional and direct digital radiographs were introduced in the Cephapoint program. 10 cephalometric points were located on a Cartesian plane (X and Y) in conventional and digital images. The measurements were taken twice by 3 operators with 1 week interval. Interobserver average error was calculated in order to assess reproducibility in each point, and intraobserver error was used to determine accuracy. RESULTS: interobserver error in soft tissue cephalometric points was less than 1 mm for most points in both images, except in chin and pogonion, with no statistically significant differences. Statistically significant differences were found between the variances in the X axis, with less variability in the case of digital radiography in these points: labrale superius (p = 0.043), subnasale (p = 0, 013), columella (p = 0.038), stomion superius (p = 0.029), and stomion inferius (p = 0.015). The Y axis did not show statistically significant differences between the two methods. The assessment of intraobserver reproducibility showed an excellent Intraclass Correlation Coefficient (ICC) (0.935) in both methods.. CONCLUSION: According to the findings of this study, the evaluated radiographs and methods offer similar diagnostic accuracy.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[cefalometría]]></kwd>
<kwd lng="es"><![CDATA[reproducibilidad de resultados]]></kwd>
<kwd lng="es"><![CDATA[radiografía]]></kwd>
<kwd lng="es"><![CDATA[imagen radiográfica por emisión de doble fotón]]></kwd>
<kwd lng="en"><![CDATA[cephalometry]]></kwd>
<kwd lng="en"><![CDATA[results reproducibility]]></kwd>
<kwd lng="en"><![CDATA[radiography]]></kwd>
<kwd lng="en"><![CDATA[double-photon emission radiographic image]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>REPRODUCIBILIDAD EN LA UBICACI&Oacute;N DE PUNTOS CEFALOM&Eacute;TRICOS DE TEJIDOS BLANDOS EN RADIOGRAF&Iacute;AS CONVENCIONALES Y DIGITALES DIRECTAS</sup> </b></font></p>          <p>&nbsp;</p>           <p>&nbsp;</p>     <b>Margarita Mar&iacute;a Bonilla Londo&ntilde;o<sup>1</sup>; Judith Patricia Barrera Chaparro<sup>2</sup>; Angela Ptricia Arroyave Godoy<SUP>3</SUP>; M&oacute;nica Eliana D&iacute;az Roa<sup>4</sup></b></p>         <p>&nbsp;</p>         <p><sup>1 </sup>Odont&oacute;loga, especialista en Ortodoncia. Fundaci&oacute;n Universitaria San Mart&iacute;n. Bogot&aacute;, Colombia</p>     <p>    <sup>2</sup> Odont&oacute;loga, especialista en Epidemiolog&iacute;a. Docente de Investigaci&oacute;n. Facultad de Postgrados de Odontolog&iacute;a. Fundaci&oacute;n Universitaria San Mart&iacute;n. Bogot&aacute;, Colombia. Correo electr&oacute;nico: <a href="mailto:barrerajudith@gmail.com">barrerajudith@gmail.com</a></p>     <p>        <sup>3</sup> Odont&oacute;loga, especialista en Ortodoncia. Fundaci&oacute;n Universitaria San Mart&iacute;n. Bogot&aacute;, Colombia</p>     ]]></body>
<body><![CDATA[<p>    <sup>4</sup> Odont&oacute;loga, especialista en Ortodoncia. Fundaci&oacute;n Universitaria San Mart&iacute;n. Bogot&aacute;, Colombia </p>     <p>&nbsp;</p>      <p><b>RECIBIDO: MAYO 8/2012-ACEPTADO: JULIO 30/2013</b></p>      <p>&nbsp;</p>        <p>Bonilla MM, Barrera JP, Arroyave &Aacute;P, D&iacute;az ME. Reproducibilidad en la ubicaci&oacute;n de puntos cefalom&eacute;tricos de tejidos blandos en radiograf&iacute;as convencionales y digitales directas. Rev Fac Odontol Univ Antioq 2013; 25(1): 76-91.</p>      <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> es escasa la informaci&oacute;n sobre la reproducibilidad de puntos cefalom&eacute;tricos de tejidos blandos, el prop&oacute;sito de este estudio fue evaluar la reproducibilidad y precisi&oacute;n de la ubicaci&oacute;n de los puntos cefalom&eacute;tricos de tejidos blandos en una radiograf&iacute;a digital directa y una radiograf&iacute;a convencional.  <b>M&Eacute;TODOS:</b> se utilizaron 11 pares de radiograf&iacute;as convencionales y radiograf&iacute;as digitales directas las cuales se introdujeron en el programa Cephapoint. Se ubicaron 10 puntos cefalom&eacute;tricos en un plano cartesiano (X y Y) en las im&aacute;genes convencional y digital. Las medidas fueron hechas dos veces por 3 operadores con intervalo de 1 semana. Se hall&oacute; el promedio de error interobservador para medir la reproducibilidad de cada punto y el error intraobservador para determinar la precisi&oacute;n.  <b>RESULTADOS:</b> el error interobservador en la ubicaci&oacute;n de puntos cefalom&eacute;tricos en tejidos blandos fue menor a 1 mm para la mayor&iacute;a de los puntos en ambas im&aacute;genes, excepto para ment&oacute;n y pogonion, sin diferencias estad&iacute;sticamente significativas. Se encontraron diferencias estad&iacute;sticamente significativas entre las varianzas en el eje X, con menor variabilidad para la radiograf&iacute;a digital en los puntos labrale superior (p = 0,043), subnasal (p = 0, 013), columnella (p = 0,038), stomion superior (p = 0,029) y stomion inferior (p = 0,015). En el eje y no se presentaron diferencias estad&iacute;sticamente significativas entre los dos m&eacute;todos. La evaluaci&oacute;n de la reproducibilidad intraobservador mostr&oacute; coeficiente de correlaci&oacute;n intraclase (CCI) excelente (0,935) en ambos m&eacute;todos.  <b>CONCLUSI&Oacute;N:</b> de acuerdo con los hallazgos de este estudio las radiograf&iacute;as y los m&eacute;todos evaluados brindan igual validez diagn&oacute;stica.</p>       <p><b>Palabras clave:</b> cefalometr&iacute;a, reproducibilidad de resultados, radiograf&iacute;a, imagen radiogr&aacute;fica por emisi&oacute;n de doble fot&oacute;n.</p>  <hr noshade>             ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      <p>En ortodoncia, gran parte del &eacute;xito del tratamiento y la satisfacci&oacute;n del paciente, se basan en varios aspectos como el diagn&oacute;stico, las diferentes opciones terap&eacute;uticas y la habilidad del operador. El diagn&oacute;stico oportuno y adecuado es fundamental para establecer los objetivos del tratamiento, siendo necesarios varios medios y herramientas entre los cuales est&aacute; el trazado cefalom&eacute;trico, utilizado desde 1930, para la evaluaci&oacute;n de datos antropom&eacute;tricos.<sup>1</sup> Este se basa en la toma de medidas, usando una radiograf&iacute;a de cr&aacute;neo del paciente, en donde se ubican puntos, se trazan planos y se miden &aacute;ngulos; los resultados son comparados con unas medidas preestablecidas por diferentes estudios,<sup>2-6</sup> de acuerdo con estas investigaciones se han estandarizado los m&eacute;todos de an&aacute;lisis, que han hecho posible que el desarrollo del trazado cefalom&eacute;trico se considere como un medio diagn&oacute;stico confiable.<sup>7</sup></p>      <p>Los equipos para la toma de radiograf&iacute;as convencionales se est&aacute;n reemplazando por tecnolog&iacute;a digital, la cual ofrece como ventaja la adquisici&oacute;n instant&aacute;nea de la imagen, su f&aacute;cil almacenamiento, la eliminaci&oacute;n del proceso de revelado y la posibilidad de compartir la imagen de manera virtual.<sup>8</sup></p>      <p>Para evaluar la reproducibilidad (error interobservador) en la ubicaci&oacute;n de los puntos cefalom&eacute;tricos en la radiograf&iacute;a digital y convencional se han hecho diversos estudios que comparan estos dos tipos de radiograf&iacute;as.<sup>8-11</sup> Estos estudios muestran que la reproducibilidad de la identificaci&oacute;n de los puntos en las im&aacute;genes digitales fue comparable a la de las radiograf&iacute;as originales.</p>      <p>Recientemente Bonilla y colaboradores<sup>12</sup> hicieron un estudio para determinar la reproducibilidad de 14 puntos cefalom&eacute;tricos en tejidos duros; en ese estudio crearon y usaron el <i>software</i> Cephapoint, que permite la ubicaci&oacute;n de puntos en un monitor de computador directamente con el cursor, usaron una muestra de 22 radiograf&iacute;as, 11 radiograf&iacute;as convencionales y 11 digitales, cada par tomado en un mismo paciente y en el mismo equipo, en el cual, primero se hizo la toma de la radiograf&iacute;a digital y al momento siguiente se hizo la toma de la radiograf&iacute;a convencional. Encontraron que todos los puntos presentan similar reproducibilidad en las dos radiograf&iacute;as, excepto infraorbitario, espina nasal posterior, articular, porion y basion con menor error interobservador en la imagen digital directa; en otro estudio, Sandler report&oacute; que los puntos articular y gonion son m&aacute;s reproducibles con el trazo manual.<sup>13</sup></p>      <p>Se encuentran pocos estudios que determinen la fiabilidad en la identificaci&oacute;n de puntos de referencia de tejidos blandos.<sup>14-17</sup> Wisth y B&ouml;e<sup>15</sup> refieren que las medidas de tejidos blandos dependen m&aacute;s de la calidad de la cefalometr&iacute;a convencional que las medidas de tejidos duros. Tambi&eacute;n Hagemann y colaboradores<sup>16</sup> informaron que la reproducibilidad de pronasal y pogonion de tejidos blandos, fue mejor en la imagen digital que en la convencional. Por su parte, Dvortsin,<sup>17</sup> comparando un trazo manual en una impresi&oacute;n 1:1 con el software Viewbox&reg; 3.1.1.9 en tejidos blandos, observ&oacute; que el &aacute;rea alrededor de stomion fue la menos reproducible, aunque se encontraron diferencias peque&ntilde;as estad&iacute;sticamente significativas, la relevancia cl&iacute;nica de estos resultados es cuestionable.</p>      <p>Dada la escasa informaci&oacute;n hallada en la literatura, el objetivo de este estudio fue evaluar la reproducibilidad de la ubicaci&oacute;n de los puntos cefalom&eacute;tricos de tejidos blandos utilizando una radiograf&iacute;a digital directa y una radiograf&iacute;a convencional.</p>      <p><b>Declaraci&oacute;n de conflicto de inter&eacute;s</b></p>      ]]></body>
<body><![CDATA[<p>Los autores declaran que &eacute;sta investigaci&oacute;n no tienen conflicto de inter&eacute;s. El estudio fue aprobado por el Comit&eacute; de bio&eacute;tica de la Facultad de Odontolog&iacute;a de la Fundaci&oacute;n Universitaria San Mart&iacute;n.</p>        <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>M&Eacute;TODOS</b></font></p>     <p>Se dise&ntilde;&oacute; un estudio de concordancia en el que se utilizaron 11 radiograf&iacute;as de perfil digitales directas, tomadas a estudiantes de ortodoncia, previo consentimiento informado, utilizadas en un estudio previo por Bonilla y colaboradores.<sup>12</sup> El uso de este material con fines de investigaci&oacute;n, fue aprobado por el Comit&eacute; de&eacute;tica de Posgrados de Odontolog&iacute;a de la Fundaci&oacute;n Universitaria San Mart&iacute;n (FUSM).</p>      <p>Las radiograf&iacute;as fueron tomadas en la posici&oacute;n natural de la cabeza, por un operador entrenado. Para cada participante se obtuvieron dos radiograf&iacute;as, una radiograf&iacute;a mediante el proceso convencional de revelado, tomada con el equipo Veraview Epocs J Morita&reg;, estas radiograf&iacute;as fueron escaneadas para transformarlas a una imagen an&aacute;loga en un formato digital utilizando el esc&aacute;ner HP Deskjet F 4180&reg;, con resoluci&oacute;n de 600 dpi; tambi&eacute;n se obtuvo una imagen radiogr&aacute;fica digital directa fosfoactivada, procesada en el equipo FCR CAPSULA X&reg;, la cual transfiere la imagen inmediatamente del equipo al monitor del computador. Las dos im&aacute;genes radiogr&aacute;ficas de cada participante fueron importadas al programa Cephapoint, dise&ntilde;ado para ubicar los puntos cefalom&eacute;tricos.<sup>12</sup></p>      <p>Los puntos de tejidos blandos fueron seleccionados teniendo en cuenta que son de ubicaci&oacute;n directa, es decir, no son puntos construidos, por lo que no fue necesario dibujar estructuras anat&oacute;micas que dependen del criterio del operador, lo cual permiti&oacute; el control de sesgos del estudio; estos fueron: labrale superior (Ls), labrale inferior (Li), subnasal (Sn), glabela (G'), columnela (Cm), ment&oacute;n (Me), pogonion (Pg'), stomion superior (Stms), stomion inferior (Stmi) y bermell&oacute;n inferior (Vmi).</p>      <p>Los puntos cefalom&eacute;tricos se ubicaron directamente en la imagen desplegada en un monitor de 14 pulgadas marca Toshiba&reg;, con un cursor controlado con un rat&oacute;n en conexi&oacute;n con el programa Cephapoint dise&ntilde;ado para un estudio previo.<sup>12</sup> Despu&eacute;s de registrar cada punto cef&eacute;trico con el rat&oacute;n, la imagen en el monitor indicaba su posici&oacute;n. Esta &uacute;ltima pod&iacute;a ser corregida hasta que el operador estuviera satisfecho. Los puntos fueron registrados en un formato de coordenadas X y Y. El eje X de referencia del programa computarizado fue el borde superior de la imagen y el eje Y, el borde anterior de esta.</p>       <p>La posici&oacute;n promedio de tres observadores para cada uno de los puntos cefalom&eacute;tricos de tejidos blandos fue definida como el "par&aacute;metro de referencia" en este estudio. Este par&aacute;metro fue utilizado para determinar los errores interobservador en las im&aacute;genes (convencional y digital). La distancia promedio en mil&iacute;metros entre el par&aacute;metro de referencia y las localizaciones hechas por los observadores fue definida como el error interobservador, este a su vez, fue utilizado como la variable que determina la reproducibilidad para cada punto. Consecuentemente, la reproducibilidad en la identificaci&oacute;n de puntos para cada una de las 2 im&aacute;genes (convencional y digital) podr&iacute;a ser comparada como las diferencias en la magnitud de estas distancias desde el promedio, entre los dos tipos de imagen.</p>      <p>La precisi&oacute;n o el error intraobservador se define como el nivel de acuerdo de las mediciones de cada uno de los tres observadores, indicando qu&eacute; tan cerca se encuentran los puntos cef&eacute;tricos ubicados en la primera y la segunda observaci&oacute;n con intervalos semanales. Se obtiene comparando las medidas de cada operador y se calcula con el m&eacute;todo estad&iacute;stico coeficiente de correlaci&oacute;n intraclase (CCI). La <a href="#f1">figura 1</a> muestra el dise&ntilde;o del estudio.</p>     <p align="center"><a name="f1"><img src=/img/revistas/rfoua/v25n1/v25n1a05f1.jpg></a> </p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>AN&Aacute;LISIS ESTAD&Iacute;STICO</b></font></p>      <p>Los datos fueron recogidos en Microsoft Excel versi&oacute;n 2007 y se analizaron en el programa estad&iacute;stico para Ciencias Sociales SPSS versi&oacute;n 15.0. Las variables cuantitativas se analizaron por medio de promedios y desviaciones est&aacute;ndar, para la comparaci&oacute;n entre el m&eacute;todo convencional y digital, se utiliz&oacute; la prueba t-student para grupos independientes y la prueba de Levene para igualdad de varianzas. En todas las pruebas se utiliz&oacute; el nivel de significancia &Alpha; = 0,05, los intervalos de confianza se utilizaron con 95% de confiabilidad. </p>        <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>      <p><b>Reproducibilidad</b></p>      <p>En la imagen convencional, los puntos que presentaron mayor promedio de error interobservador en la ubicaci&oacute;n en el eje X fueron: ment&oacute;n (0,816 mm) y pogonion (0,699 mm). Con respecto al eje Y, los mayores promedios se observaron en: labrale superior (0,687 mm) y ment&oacute;n (0,672 mm). En la imagen digital directa, los puntos que presentaron error interobservador mayor en el eje X, fueron pogonion (0,792 mm) y ment&oacute;n (0,78 mm). Con respecto al eje Y, el mayor promedio se present&oacute; en ment&oacute;n (0,724 mm), seguido de pogonion (0,604 mm) y labrale superior (0,594 mm). Ning&uacute;n error interobservador fue mayor a 1 mm en los dos tipos de radiograf&iacute;as. Al comparar el promedio del error interobservador entre la imagen convencional y digital directa, no se encontraron diferencias estad&iacute;sticamente significativas (p &ge; 0,05). </p>       <p>En la mayor&iacute;a de los puntos, el nivel de dispersi&oacute;n del error interobservador fue menor en la radiograf&iacute;a digital como lo indican los datos de desviaci&oacute;n est&aacute;ndar, excepto en el eje X para el punto glabela y en el eje Y para los puntos labrale superior, subnasal, columnella, stomion superior y stomion inferior (<a href="#t1">tabla 1</a>). </p>      <p align="center"><a name="t1"><img src=/img/revistas/rfoua/v25n1/v25n1a05t1.jpg></a> </p>      <p>Se compararon los valores de desviaci&oacute;n est&aacute;ndar entre los m&eacute;todos convencional y digital, independientemente del valor promedio de cada punto (prueba F de Fisher), lo cual se considera un indicador de error interobservador m&aacute;s confiable, ya que la desviaci&oacute;n est&aacute;ndar mide los niveles de dispersi&oacute;n del error. Se encontr&oacute; diferencia estad&iacute;sticamente significativa entre la desviaci&oacute;n est&aacute;ndar (DE) en el eje X en labrale superior (p = 0,043), subnasal (p = 0,013), columnella (p = 0,038), stomion superior (p = 0,029) y stomion inferior (p = 0,015). Estas diferencias favorecen a la radiograf&iacute;a digital como se observa por sus menores valores de desviaci&oacute;n est&aacute;ndar. En el eje Y no se presentaron diferencias estad&iacute;sticamente significativas entre los dos m&eacute;todos (<a href="#t1">tabla 1</a>). </p>       ]]></body>
<body><![CDATA[<p>Con el fin de calcular la reproducibilidad de cada punto, integrando los valores obtenidos en los ejes X y Y, se hall&oacute; la distancia euclidiana. Se observan promedios de error interobservador mayores de 1 mm en la radiograf&iacute;a convencional para los puntos ment&oacute;n (1,214 mm), pogonion (1,043 mm), y en la radiograf&iacute;a digital los promedios mayores de 1 mm fueron ment&oacute;n (1,206 mm), pogonion (1,131 mm), labrale superior (1,041 mm), labrale inferior (1,027 mm), bermell&oacute;n inferior (1,015 mm), sin diferencias estad&iacute;sticamente significativas entre los m&eacute;todos. </p>       <p>Las mayores desviaciones est&aacute;ndar en el m&eacute;todo convencional se encontraron en los puntos ment&oacute;n (0, 667 mm) y pogonion (0, 611 mm) y en el m&eacute;todo digital ment&oacute;n (0,634 mm). Al comparar las desviaciones est&aacute;ndar, se encontraron diferencias estad&iacute;sticamente significativas (p &lt; 0,01) en la dispersi&oacute;n entre las im&aacute;genes convencional y digital directa, observando mayor nivel de significancia en labrale inferior (p = 0,003) y stomion superior (p = 0,047); se observan valores m&aacute;s altos de dispersi&oacute;n para la radiograf&iacute;a convencional, lo que indica menor reproducibilidad debido a que su desviaci&oacute;n est&aacute;ndar es mayor (<a href="#t2">tabla 2</a>). </p>      <p align="center"><a name="t2"><img src=/img/revistas/rfoua/v25n1/v25n1a05t2.jpg></a> </p>      <p><b>Precisi&oacute;n</b></p>     <p>La evaluaci&oacute;n de la reproducibilidad intraobservador mostr&oacute; CCI excelente en ambos m&eacute;todos, fue mayor de 0,928 para &eacute;todo convencional (<a href="#t3">tabla 3</a>). </p>      <p align="center"><a name="t3"><img src=/img/revistas/rfoua/v25n1/v25n1a05t3.jpg></a> </p>      <p>El CCI en el m&eacute;todo digital estuvo por encima de 0,935 con excepci&oacute;n del punto ment&oacute;n el cual fue de 0,644 en el observador 3 (<a href="#t4">tabla 4</a>) </p>      <p align="center"><a name="t4"><img src=/img/revistas/rfoua/v25n1/v25n1a05t4.jpg></a> </p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p>Algunos estudios que comparan radiograf&iacute;as convencionales con digitales grabadas al mismo tiempo, muestran m&aacute;s reproducibles las mediciones para las im&aacute;genes digitales debido a la mejor visi&oacute;n de los tejidos blandos.<sup>18-19</sup></p>      <p>Otros autores indican que aunque las im&aacute;genes digitales se pueden mejorar, esto solo aumenta la reproducibilidad y no la precisi&oacute;n. <sup>19-20</sup> Sin embargo, la p&eacute;rdida de detalle que se produce cuando una imagen es comprimida en formato JPEG no afecta significativamente la calidad diagn&oacute;stica.<sup>10</sup></p>      <p>En el presente estudio se encontr&oacute; que los promedios de error interobservador para los m&eacute;todos convencional y digital en los ejes X y Y, en la distancia euclidiana no presentaron diferencias significativas entre l&eacute;todos; sin embargo, hubo valores m&aacute;s altos de error para los puntos ment&oacute;n y pogonion, con promedios mayores a 1 mm en la distancia euclidiana; estos puntos presentaron dificultad en la ubicaci&oacute;n en la radiograf&iacute;a convencional debido al predominio de una zona radiol&uacute;cida que hace menos visibles los tejidos blandos en estas &aacute;reas. En contraste, Hagemann y colaboradores compararon radiograf&iacute;as digitales con convencionales y encontraron que los puntos pronasal y pogonion de tejidos blandos fueron m&aacute;s reproducibles en la imagen digital.<sup>16</sup></p>      <p>Otro hallazgo del presente estudio indica que en la radiograf&iacute;a digital los puntos labrale superior, labrale inferior y bermell&oacute;n inferior, presentaron valores de error interobservador mayores a 1 mm, pero sin diferencias significativas con la imagen convencional, lo cual permite pensar que el punto bermell&oacute;n inferior present&oacute; mayor dificultad en su localizaci&oacute;n, debido a que en la imagen radiogr&aacute;fica bidimensional no permite ver claramente en d&oacute;nde termina el labio inferior. Otros autores que compararon trazado digital y manual encontraron diferencias estad&iacute;sticamente significativas entre los m&eacute;todos digital y manual en el punto labrale inferior,<sup>20</sup> tambi&eacute;n Cooke y Wei, encontraron que las prominencias de los labios eran sitios de pobre identificaci&oacute;n cuando se hac&iacute;a el trazo manual.<sup>21</sup></p>      <p>En cuanto a la dispersi&oacute;n, registrada seg&uacute;n los datos de desviaci&oacute;n est&aacute;ndar, lo cual se consider&oacute; en este estudio como una medida m&aacute;s confiable de la reproducibilidad, se encontraron diferencias estad&iacute;sticamente significativas en los puntos labrale superior, subnasal, columnela, stomion superior, stomion inferior en el eje X y se encontraron mayor reproducibilidad en la radiograf&iacute;a digital. En cuanto a la distancia euclidiana los puntos labrale inferior y stomion superior fueron m&aacute;s reproducibles en la imagen digital, la cual fue m&aacute;s precisa y exacta. La menor dispersi&oacute;n del error interobservador en la imagen digital, puede ser atribuida a que estas radiograf&iacute;as presentan mayor nitidez y contraste en la escala de grises.</p>       <p>En el presente estudio, stomion superior present&oacute; mayor dispersi&oacute;n en la imagen convencional debido a que su localizaci&oacute;n se encuentra en el &aacute;rea m&aacute;s curva de los labios haciendo m&aacute;s dif&iacute;cil la ubicaci&oacute;n de su parte m&aacute;s inferior. Otros autores, encontraron que stomion era menos reproducible, debido a que algunos individuos ten&iacute;an los labios en contacto, mientras que en otros, los labios est&aacute;n ligeramente separados en reposo, por lo que ubicar este punto presenta dificultad sobre todo en pacientes con labios separados.<sup>17, 20</sup></p>      <p>El punto glabela fue el m&aacute;s reproducible tanto en la radiograf&iacute;a digital como convencional con respecto a la distancia euclidiana; similares hallazgos fueron reportados en el estudio de Lim y colaboradores, en el que compararon la confiabilidad entre la cefalometr&iacute;a lateral computarizada y la localizaci&oacute;n de los puntos manuales en una radiograf&iacute;a convencional.<sup>22</sup></p>      <p>En el presente estudio se aplic&oacute; el CCI, para evaluar la reproducibilidad intraobservador en cada uno de los tres observadores, se obtuvo un valor superior a 0,90 el cual fue un excelente resultado, similar a lo reportado en otros estudios.<sup>11, 23-25</sup> Estos resultados indican un alto nivel de precisi&oacute;n en la medici&oacute;n gracias al adecuado entrenamiento de los observadores en la evaluaci&oacute;n, por lo tanto, las diferencia encontradas se atribuyen exclusivamente a los m&eacute;todos evaluados.</p>      <p>El desarrollo de programas inform&aacute;ticos para trazado cefalom&eacute;trico ha brindado nuevas posibilidades al ortodoncista porque permiten la manipulaci&oacute;n de la calidad de la imagen para obtener mayor claridad sobre todo en los tejidos blandos; sin embargo, pocos estudios han comparado la ubicaci&oacute;n de puntos cefalom&eacute;tricos y medidas de tejidos blandos en im&aacute;genes digitales y convencionales, este hecho limita las comparaciones del presente estudio. <sup>18, 26-27</sup></p>      ]]></body>
<body><![CDATA[<p>Kawahara y colaboradores reportan que no hubo diferencia estad&iacute;sticamente significativa entre la radiograf&iacute;a convencional y la digital, concluyen que independientemente del m&eacute;todo aplicado o del cl&iacute;nico que realice el trazo manual o con <i>software</i>, este debe estar entrenado y calibrado para la ejecuci&oacute;n del mismo;<sup>28</sup> raz&oacute;n por la cual en este estudio se introdujo la evaluaci&oacute;n intraobservador con resultados satisfactorios.</p>      <p>De acuerdo con los resultados de este estudio las diferencias en estos m&eacute;todos no son cl&iacute;nicamente relevantes por lo que la aplicaci&oacute;n de uno u otro an&aacute;lisis no afecta el diagn&oacute;stico. Independientemente del m&eacute;todo aplicado el individuo debe estar entrenado y calibrado para la ejecuci&oacute;n del mismo. Por lo tanto, la elecci&oacute;n del m&eacute;todo de an&aacute;lisis depende del criterio del ortodoncista en cuanto a la valoraci&oacute;n de ventajas, desventajas, costos, tiempo, accesibilidad y comodidad.</p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>&nbsp;</p>      <p>La reproducibilidad medida como el error interobservador fue menor a 1 mm para la mayor&iacute;a de los puntos en la imagen convencional y en la digital, excepto para ment&oacute;n y pogonion, sin diferencias estad&iacute;sticamente significativas.</p>      <p>Los puntos labrale inferior y stomion superior fueron m&aacute;s precisos en la imagen digital con respecto a la imagen convencional con diferencias estad&iacute;sticamente significativas.</p>      <p>De acuerdo con los hallazgos de este estudio los dos m&eacute;todos presentan igual validez diagn&oacute;stica.</p>       <p>&nbsp;</p>       <p><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <!-- ref --><p>1. De Araujo P, Nascimento J, Mesquita F, Nery E. A comparative study of manual vs. computerized cephalometric analysis. Dental Press J Orthod 2010; 15(2): 44-51.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0121-246X201300020000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Steiner C. Cephalometrics for you and me. Am J Orthod 1953; 39(10): 729-755.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0121-246X201300020000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Legan HL, Burstone CJ. Soft tissue cephalometric analysis for orthognathic surgery. J Oral Surg 1980; 38(10): 744-751.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0121-246X201300020000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Burstone CJ, James RB, Legan H, Murphy GA, Norton LA. Cephalometrics for orthognathic surgery. J Oral Surg 1978; 36(4): 269-277.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0121-246X201300020000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. McNamara JA Jr. A method of cephalometric evaluation. Am J Orthod 1984; 86(6): 449-469.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0121-246X201300020000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Sassouni V. A classification of skeletal facial types. Am J Orthod 1969; 55(2): 109-123.Vion P. Anatom&iacute;a cefalom&eacute;trica. S&atilde;o Paulo, Brasil: Ed. Santos. 1994: 45-60.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0121-246X201300020000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>7. Chung RR, Lagravere MO, Flores-Mir C, Heo G, Carey JP, Major PW. A comparative analysis of angular cephalometric values between CBCT generated lateral cephalograms versus digitized conventional lateral cephalograms. Int Orthod 2009; 7(4): 308-321.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0121-246X201300020000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Bruntz LQ, Palomo JM, Baden S, Hans MG. A comparison of scanned lateral cephalograms with corresponding original radiographs. Am J Orthod Dentofacial Orthop 2006; 130(3): 340-348.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0121-246X201300020000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Uysal T, Baysal A, Yagci A. Evaluation of speed, repeatability, and reproducibility of  digital radiography with manual versus computer-assisted cephalometric analyses. Eur J Orthod. 2009; 31(5):523-528.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0121-246X201300020000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Sayinsu K, Isik F, Trakyali G, Arun T. An evaluation of the errors in cephalometric measurements on scanned cephalometric images and conventional tracings. Eur J Orthod 2007; 29(1): 105-108.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0121-246X201300020000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>11. Yu SH, Nahm DS, Baek SH. Reliability of landmark identification on monitor-displayed lateral cephalometric images. Am J Orthod Dentofacial Orthop 2008; 133(6): 790.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0121-246X201300020000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Bonilla M, Barrera J, Guti&eacute;rrez D, Paredes M, Puentes J. Comparaci&oacute;n del error en la ubicaci&oacute;n de puntos cefalom&eacute;tricos entre una imagen digital directa y una convencional. Revista Cient&iacute;fica Sociedad Colombiana de Ortodoncia 2011; 18(17): 63-71.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0121-246X201300020000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>13. Sandler PJ. Reproducibility of cephalometric measurements. Br J Orthod 1988; 15(2): 105-110.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0121-246X201300020000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Swennen GR, Grimaldi H, Berten JL, Kramer FJ, Dempf R, Schwestka-Polly R et al. Reliability and validity of a modified lateral cephalometric analysis for evaluation of craniofacial morphology and growth in patients with clefts. J Craniofac Surg 2004; 15(3): 399-412.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0121-246X201300020000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Wisth PJ, B&ouml;e OE. The reliability of cephalometric soft tissue measurements. Arch Oral Biol 1975; 20(9): 595- 599.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0121-246X201300020000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Hagemann K, Vollmer D, Niegel T, Ehmer U, Reuter I. Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms. J Orofac Orthop 2000; 61(2): 91-99.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0121-246X201300020000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Dvortsin DP, Sandham A, Pruim GJ, Dijkstra PU. A comparison of the reproducibility of manual tracing and on-screen digitization for cephalometric profile variables. Eur J Orthod 2008; 30(6): 586-591.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0121-246X201300020000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>18. Eppley BL, Sadove AM. Computerized digital enhancement in craniofacial cephalometric radiography. J Oral Maxillofac Surg 1991; 49(10): 1038-1043.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0121-246X201300020000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. Macr&iacute; V, Wenzel A. Reliability of landmark recording on film and digital lateral cephalograms. Eur J Orthod 1993; 15(2): 137-48.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0121-246X201300020000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Naoumova J, Lindman R. A comparison of manual traced images and corresponding scanned radiographs digitally traced. Eur J Orthod 2009; 31: 247-253.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X201300020000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Cooke M, Wei H. Cephalometric errors: a comparison between repeat measurements and retaken radiographs. Aust Dent J 1991; 36: 38-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0121-246X201300020000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Lim KF, Foong KW. Phosphor-stimulated Computed Cephalometry: Reliability of Landmark Identification. Br J Orthod 1997; 24: 301-308.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X201300020000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23. Polat-Ozsoy O, Gokcelik A, Toygar Memikoglu TU. Differences in cephalomatric measurements: a comparison of digital versus hand-tracing methods. Eur J Orthod 2009; 31: 254-259.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0121-246X201300020000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24. Ongkosuwito E, Katsaros C, Hof M, Bodegon J, Kuijpers- Jagtman A. The reproducibility of cephalometric measurements; a comparison of analogue and digital methods. Eur J Orthod 2004; 24: 655-665.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X201300020000500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>25. Tsorovas G, Karsten AL. A comparison of hand-tracing and cephalometric analysis computer programs with and without advanced features-accuracy and tune demands. Eur J Orthod 2010; 10:1-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201300020000500025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Chen YJ, Chen SK, Yao JC, Chang HF. The effects of differences in landmark identification on the cephalometric measurements in traditional versus digitized cephalometry. Angle Orthod 2004; 74(2): 155-161.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X201300020000500026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <p>&nbsp;</p>     <p> </p> </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De]]></surname>
<given-names><![CDATA[Araujo P]]></given-names>
</name>
<name>
<surname><![CDATA[Nascimento]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mesquita]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Nery]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative study of manual vs. computerized cephalometric analysis]]></article-title>
<source><![CDATA[Dental Press J Orthod]]></source>
<year>2010</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>44-51</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steiner]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cephalometrics for you and me]]></article-title>
<source><![CDATA[Am J Orthod]]></source>
<year>1953</year>
<volume>39</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>729-755</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Legan]]></surname>
<given-names><![CDATA[HL]]></given-names>
</name>
<name>
<surname><![CDATA[Burstone]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Soft tissue cephalometric analysis for orthognathic surgery]]></article-title>
<source><![CDATA[J Oral Surg]]></source>
<year>1980</year>
<volume>38</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>744-751</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burstone]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[James]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Legan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Murphy]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cephalometrics for orthognathic surgery]]></article-title>
<source><![CDATA[J Oral Surg]]></source>
<year>1978</year>
<volume>36</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>269-277</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McNamara]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A method of cephalometric evaluation]]></article-title>
<source><![CDATA[Am J Orthod]]></source>
<year>1984</year>
<volume>86</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>449-469</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sassouni]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A classification of skeletal facial types]]></article-title>
<source><![CDATA[Am J Orthod]]></source>
<year>1969</year>
<volume>55</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>109-123</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Lagravere]]></surname>
<given-names><![CDATA[MO]]></given-names>
</name>
<name>
<surname><![CDATA[Flores-Mir]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Heo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Carey]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Major]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative analysis of angular cephalometric values between CBCT generated lateral cephalograms versus digitized conventional lateral cephalograms]]></article-title>
<source><![CDATA[Int Orthod]]></source>
<year>2009</year>
<volume>7</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>308-321</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bruntz]]></surname>
<given-names><![CDATA[LQ]]></given-names>
</name>
<name>
<surname><![CDATA[Palomo]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Baden]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hans]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of scanned lateral cephalograms with corresponding original radiographs]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2006</year>
<volume>130</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>340-348</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Uysal]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Baysal]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yagci]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2009</year>
<volume>31</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>523-528</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sayinsu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Isik]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Trakyali]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Arun]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An evaluation of the errors in cephalometric measurements on scanned cephalometric images and conventional tracings]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2007</year>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>105-108</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[Nahm]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Baek]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability of landmark identification on monitor-displayed lateral cephalometric images]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2008</year>
<volume>133</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>790</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bonilla]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Barrera]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Paredes]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Puentes]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Comparación del error en la ubicación de puntos cefalométricos entre una imagen digital directa y una convencional]]></article-title>
<source><![CDATA[Revista Científica Sociedad Colombiana de Ortodoncia]]></source>
<year>2011</year>
<volume>18</volume>
<numero>17</numero>
<issue>17</issue>
<page-range>63-71</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sandler]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reproducibility of cephalometric measurements]]></article-title>
<source><![CDATA[Br J Orthod]]></source>
<year>1988</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>105-110</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Swennen]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Grimaldi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Berten]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Kramer]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dempf]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Schwestka-Polly]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability and validity of a modified lateral cephalometric analysis for evaluation of craniofacial morphology and growth in patients with clefts]]></article-title>
<source><![CDATA[J Craniofac Surg]]></source>
<year>2004</year>
<volume>15</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>399-412</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wisth]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Böe]]></surname>
<given-names><![CDATA[OE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The reliability of cephalometric soft tissue measurements]]></article-title>
<source><![CDATA[Arch Oral Biol]]></source>
<year>1975</year>
<volume>20</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>595- 599</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hagemann]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Vollmer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Niegel]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ehmer]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Reuter]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms]]></article-title>
<source><![CDATA[J Orofac Orthop]]></source>
<year>2000</year>
<volume>61</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>91-99</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dvortsin]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
<name>
<surname><![CDATA[Sandham]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pruim]]></surname>
<given-names><![CDATA[GJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dijkstra]]></surname>
<given-names><![CDATA[PU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the reproducibility of manual tracing and on-screen digitization for cephalometric profile variables]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2008</year>
<volume>30</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>586-591</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eppley]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Sadove]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computerized digital enhancement in craniofacial cephalometric radiography]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>1991</year>
<volume>49</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1038-1043</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Macrí]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Wenzel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability of landmark recording on film and digital lateral cephalograms]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>1993</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>137-48</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Naoumova]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lindman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of manual traced images and corresponding scanned radiographs digitally traced]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2009</year>
<volume>31</volume>
<page-range>247-253</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooke]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wei]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cephalometric errors: a comparison between repeat measurements and retaken radiographs]]></article-title>
<source><![CDATA[Aust Dent J]]></source>
<year>1991</year>
<volume>36</volume>
<page-range>38-43</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lim]]></surname>
<given-names><![CDATA[KF]]></given-names>
</name>
<name>
<surname><![CDATA[Foong]]></surname>
<given-names><![CDATA[KW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Phosphor-stimulated Computed Cephalometry: Reliability of Landmark Identification]]></article-title>
<source><![CDATA[Br J Orthod]]></source>
<year>1997</year>
<volume>24</volume>
<page-range>301-308</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Polat-Ozsoy]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Gokcelik]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Toygar]]></surname>
<given-names><![CDATA[Memikoglu]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Differences in cephalomatric measurements: a comparison of digital versus hand-tracing methods]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2009</year>
<volume>31</volume>
<page-range>254-259</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ongkosuwito]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Katsaros]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hof]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bodegon]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kuijpers- Jagtman]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The reproducibility of cephalometric measurements; a comparison of analogue and digital methods]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2004</year>
<volume>24</volume>
<page-range>655-665</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsorovas]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Karsten]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of hand-tracing and cephalometric analysis computer programs with and without advanced features-accuracy and tune demands]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2010</year>
<volume>10</volume>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[YJ]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Yao]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[HF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effects of differences in landmark identification on the cephalometric measurements in traditional versus digitized cephalometry]]></article-title>
<source><![CDATA[Angle Orthod]]></source>
<year>2004</year>
<volume>74</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>155-161</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
