<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2014000200005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[EVALUACIÓN IN VITRO DEL EFECTO DE LA CONCENTRACIÓN Y EL TIEMPO DE APLICACIÓN DEL ÁCIDO FLUORHÍDRICO SOBRE LA ADHESIÓN AL DISILICATO DE LITIO]]></article-title>
<article-title xml:lang="en"><![CDATA[IN VITRO EVALUATION OF THE EFFECT OF HYDROFLUORIC ACID ONCENTRATION AND APPLICATION TIME ON ADHESION TO LITHIUM DISILICATE]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Caparroso Pérez]]></surname>
<given-names><![CDATA[Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Latorre Correa]]></surname>
<given-names><![CDATA[Federico]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Arroyave Hoyos]]></surname>
<given-names><![CDATA[Luz Janeth]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Grajales Gaviria]]></surname>
<given-names><![CDATA[Carlos Andrés]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Medina Piedrahita]]></surname>
<given-names><![CDATA[Verónica María]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2014</year>
</pub-date>
<volume>26</volume>
<numero>1</numero>
<fpage>62</fpage>
<lpage>75</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2014000200005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: el disilicato de litio como material cerámico restaurador ofrece resistencia superior a las cerámicas, unas excelentes características ópticas y la posibilidad de ser adherido al sustrato dentario por medio del grabado con ácido fluorhídrico. El propósito de este estudio fue evaluar in vitro el efecto del ácido fluorhídrico al 9,5 % y al 4,6 % en tiempos de 20, 40 y 60 s sobre la superficie del disilicato de litio en los procesos de adhesión a un sustrato resinoso. MÉTODOS: se confeccionaron 6 cubos de porcelana IPS e-max® Press y 6 cubos de resina Filtek® Z250. Los cubos cerámicos fueron sometidos a un tratamiento de superficie obteniendo 6 grupos: El grupo control y los grupos 2 y 3 utilizaron ácido fluorhídrico al 4,6%, durante 20, 40 y 60 s respectivamente, los grupos 4, 5 y 6 usaron ácido fluorhídrico al 9,5%, en tiempos de 20, 40 y 60 s respectivamente. Se cementaron los cubos de porcelana con los de resina con cemento resinoso autoadhesivo y se generaron barras de 1 x 1 x 18 mm, obteniéndose 20 muestras en cada grupo y se midió su fuerza de adhesión. RESULTADOS: los valores de resistencia adhesiva en MPa (SD) fueron G1 = 26,69 (&plusmn; 7,99), G2 = 23,93 (&plusmn; 7,99), G3 = 20,90 (&plusmn; 7,91), G4 = 17,56 (&plusmn; 6,61), G5 = 16,30 (&plusmn; 11,68), G6 = 18,78 (&plusmn; 10,22), con diferencias significativas entre el grupo 1 y los grupos 4-5. CONCLUSIÓN: las concentraciones de ácido fluorhídrico al 4,6%, presentaron mejores promedios de adhesión en comparación con los grabados al 9,6%. El grupo con concentración al 4,6% por 20 s presentó los mejores resultados.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: as a ceramic restorative material, lithium disilicate provides higher resistance to ceramic materials, excellent optical characteristics, and the ability to be bonded to tooth substrate by hydrofluoric acid etching. The purpose of this study was to perform in vitro assessment of the effect of 4.6 and 9.5% hydrofluoric acid at 20, 40 and 60 s on the surface of lithium disilicate during the processes of adherence to a resinous substrate. METHODS: 6 IPS e-max® Press porcelain cubes and 6 Filtek Z250® resin cubes were made. The ceramic cubes were subjected to surface treatment obtaining 6 groups: control group and groups 2 and 3 were treated with 4.6% hydrofluoric acid during 20, 40 and 60 seconds respectively, and groups 4, 5 and 6 were treated with 9.5% hydrofluoric acid at 20, 40 and 60 s respectively. Porcelain cubes were cemented with the resin ones with self-adhesive resin cement and bars of 1 x 1 x 18 mm were produced, obtaining 20 samples in each group. Adhesive strength was measured. RESULTS: adhesive strength values expressed in MPa (SD) were as follows: G1 = 26.69 (&plusmn; 7.99), G2 = 23.93 (&plusmn; 7.99), G3 = 20.90 (&plusmn; 7.91), G4 = 17.56 (&plusmn; 6.61), G5 = 16.30 (&plusmn; 11.68), G6 = 18.78 (&plusmn; 10.22), with significant differences between group 1 and groups 4-5. CONCLUSIONS: 4.6% hydrofluoric acid produced better adhesive averages compared with the 9.6% concentrations. The group with 4.6% concentration during 20 s offered the best results.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[cerámica]]></kwd>
<kwd lng="es"><![CDATA[porcelana dental]]></kwd>
<kwd lng="es"><![CDATA[disilicato de litio]]></kwd>
<kwd lng="es"><![CDATA[ácido fluorhídrico]]></kwd>
<kwd lng="en"><![CDATA[ceramics]]></kwd>
<kwd lng="en"><![CDATA[dental porcelain]]></kwd>
<kwd lng="en"><![CDATA[lithium disilicate]]></kwd>
<kwd lng="en"><![CDATA[hydrofluoric acid]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>EVALUACI&Oacute;N IN VITRO DEL EFECTO DE LA CONCENTRACI&Oacute;N Y EL TIEMPO DE APLICACI&Oacute;N DEL &Aacute;CIDO FLUORH&Iacute;DRICO SOBRE LA ADHESI&Oacute;N AL DISILICATO DE LITIO</b></font></p>           <p>&nbsp;</p>           <p>&nbsp;</p>     <b>Carlos Caparroso P&eacute;rez<SUP>1</SUP>; Federico Latorre Correa<SUP>2</SUP>; Luz Janeth Arroyave Hoyos<SUP>3</SUP>; Carlos Andr&eacute;s Grajales Gaviria<SUP>3</SUP>; Ver&oacute;nica Mar&iacute;a Medina Piedrahita<SUP>3</SUP></b></p>         <p>&nbsp;</p>         <p><sup>1</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto, mag&iacute;ster en Educaci&oacute;n superior, profesor asociado, Facultad de Odontolog&iacute;a, Universidad de Antioquia. Correo electr&oacute;nico: <a href="mailto: ccaparroso@gmail.com">ccaparroso@gmail.com</a>    <br> </p>     <p><sup>2</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto, profesor   asociado, Facultad de Odontolog&iacute;a, Universidad de Antioquia. Correo   electr&oacute;nico: <a href="mailto: latorre.federico29@gmail.com">latorre.federico29@gmail.com</a>    ]]></body>
<body><![CDATA[<br>   </p>     <p><sup>3</sup> Estudiantes del posgrado de Odontolog&iacute;a Integral del Adulto con &eacute;nfasis   en Prostodoncia, Facultad de Odontolog&iacute;a, Universidad de Antioquia.</p>     <p>&nbsp;</p>      <p><b>RECIBIDO: FEBRERO 8/2013-ACEPTADO: NOVIEMBRE 19/2013</b></p>      <p>&nbsp;</p>        <p>Caparroso CB, Latorre F, Arroyave LJ, Grajales CA. Evaluaci&oacute;n in vitro del efecto de la concentraci&oacute;n y el tiempo de aplicaci&oacute;n del &aacute;cido fluorh&iacute;drico sobre la adhesi&oacute;n al disilicato de litio. Rev Fac Odontol Univ Antioq 2014; 26(1): 62-75.</p>      <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> el disilicato de litio como material cer&aacute;mico restaurador ofrece resistencia superior a las cer&aacute;micas, unas excelentes caracter&iacute;sticas &oacute;pticas y la posibilidad de ser adherido al sustrato dentario por medio del grabado con &aacute;cido fluorh&iacute;drico. El prop&oacute;sito de este estudio fue evaluar in vitro el efecto del &aacute;cido fluorh&iacute;drico al 9,5 % y al 4,6 % en tiempos de 20, 40 y 60 s sobre la superficie del disilicato de litio en los procesos de adhesi&oacute;n a un sustrato resinoso.     ]]></body>
<body><![CDATA[<br>  <b>M&Eacute;TODOS:</b> se confeccionaron 6 cubos de porcelana IPS e-max&reg; Press y 6 cubos de resina Filtek&reg; Z250. Los cubos cer&aacute;micos fueron sometidos a un tratamiento de superficie obteniendo 6 grupos: El grupo control y los grupos 2 y 3 utilizaron &aacute;cido fluorh&iacute;drico al 4,6%, durante 20, 40 y 60 s respectivamente, los grupos 4, 5 y 6 usaron &aacute;cido fluorh&iacute;drico al 9,5%, en tiempos de 20, 40 y 60 s respectivamente. Se cementaron los cubos de porcelana con los de resina con cemento resinoso autoadhesivo y se generaron barras de 1 x 1 x 18 mm, obteni&eacute;ndose 20 muestras en cada grupo y se midi&oacute; su fuerza de adhesi&oacute;n.     <br>  <b>RESULTADOS: </b>los valores de resistencia adhesiva en MPa (SD) fueron G1 = 26,69 (&plusmn; 7,99), G2 = 23,93 (&plusmn; 7,99), G3 = 20,90 (&plusmn; 7,91), G4 = 17,56 (&plusmn; 6,61), G5 = 16,30 (&plusmn; 11,68), G6 = 18,78 (&plusmn; 10,22), con diferencias significativas entre el grupo 1 y los grupos 4-5.     <br>  <b>CONCLUSI&Oacute;N: </b>las concentraciones de &aacute;cido fluorh&iacute;drico al 4,6%, presentaron mejores promedios de adhesi&oacute;n en comparaci&oacute;n con los grabados al 9,6%. El grupo con concentraci&oacute;n al 4,6% por 20 s present&oacute; los mejores resultados.</p>        <p><b>Palabras clave:</b> cer&aacute;mica, porcelana dental, disilicato de litio, &aacute;cido fluorh&iacute;drico.</p>  <hr noshade>             <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      <p>Las cer&aacute;micas feldesp&aacute;ticas tienen una estructura mixta compuesta por una fase cristalina y una fase v&iacute;trea.<sup>1</sup> Este material obtiene su retenci&oacute;n de forma micromec&aacute;nica, por medio de un arenado de la superficie o de un grabado &aacute;cido y qu&iacute;mico con agentes de uni&oacute;n o silanos.<sup>2</sup> La fase cristalina da unas mejores caracter&iacute;sticas mec&aacute;nicas, que ser&iacute;an las cer&aacute;micas de alto contenido de al&uacute;mina y zirconio, pero tienen la desventaja de disminuir los valores de adhesi&oacute;n y translucidez.<sup>2</sup> Las cer&aacute;micas a base de disilicato de litio tienen un porcentaje de 60-70 de cristales incluidos en una matriz v&iacute;trea, que les proporciona un aumento de resistencia con respecto a las cer&aacute;micas feldesp&aacute;ticas, y permiten ser acondicionadas por medio de la t&eacute;cnica de grabado &aacute;cido.<sup>3</sup></p>      <p>La adhesi&oacute;n de un compuesto resinoso a cer&aacute;micas con feldespato, leucita y disilicato de litio, est&aacute; bien establecida. El &aacute;cido fluorh&iacute;drico ataca la fase v&iacute;trea y forma una superficie retentiva para una adhesi&oacute;n micromec&aacute;nica y el silano, como agente de uni&oacute;n, promueve un enlace qu&iacute;mico entre la s&iacute;lice de estas cer&aacute;micas y los grupos metacrilato de la resina.<sup>2</sup> El proceso de adhesi&oacute;n al s&iacute;lice para la cementaci&oacute;n de cer&aacute;micas de disilicato de litio se hace por medio del grabado de superficie con &aacute;cido fluorh&iacute;drico.<sup>4</sup> Las concentraciones m&aacute;s utilizadas son al 4,6 y 9,5%. La cer&aacute;mica IPS e.max&reg; Press se introdujo en la profesi&oacute;n en el a&ntilde;o 2005, y est&aacute; compuesta por 70% de cristales de disilicato de litio (Li<sub>2</sub>Si<sub>2</sub>O<sub>5</sub>), los cuales est&aacute;n incluidos en una matriz v&iacute;trea.<sup>5</sup> Para el caso de este material, la casa fabricante recomienda el uso de &aacute;cido fluorh&iacute;drico al 4,6% durante 20 s.<sup>6</sup></p>      <p>Existen publicaciones que estudian el efecto del acondicionamiento de la superficie con &aacute;cido fluorh&iacute;drico en la adhesi&oacute;n al disilicato de litio. Kiyan y colaboradores<SUP>7</SUP> encontraron que el acondicionamiento de una superficie arenada y tratada con &aacute;cido fluorh&iacute;drico al 10%, genera niveles de adhesi&oacute;n alrededor de los 13,65 MPa. Spohr y colaboradores8 encontraron que un grabado en las mismas condiciones, con y sin la aplicaci&oacute;n del agente de uni&oacute;n o silano, los valores de adhesi&oacute;n fueron de 25,6 y 16,4 MPa respectivamente. Meyer y colaboradores,<sup>9</sup> usando el mismo tratamiento de superficie, hallaron valores de adhesi&oacute;n de 35,1 y 56,8 MPa respectivamente. G&ouml;k&ccedil;e y colaboradores,<sup>10</sup> aumentando el tiempo de grabado a 30 s con la misma concentraci&oacute;n, obtuvieron mayores niveles de adhesi&oacute;n al sustrato cer&aacute;mico. Pollington y colaboradores<sup>11</sup> encontraron que al aumentar el tiempo de grabado a 60 s con la misma concentraci&oacute;n del agente grabador, obten&iacute;an una fuerza de adhesi&oacute;n de 24,76 Mpa. Otros autores, como Kim y colaboradores,<sup>12</sup> usando una concentraci&oacute;n de &aacute;cido fluorh&iacute;drico de 4% por 5 min, lograron niveles de adhesi&oacute;n de 17,7 Mpa. Estos estudios no hicieron comparaciones entre tiempos de aplicaci&oacute;n y concentraci&oacute;n del &aacute;cido fluorh&iacute;drico en sus protocolos de cementaci&oacute;n.</p>      ]]></body>
<body><![CDATA[<p>El prop&oacute;sito de este estudio fue evaluar el efecto del &aacute;cido fluorh&iacute;drico al 9,5 y al 4,6%, en diferentes tiempos de aplicaci&oacute;n de 20, 40 y 60 s, sobre la superficie del disilicato de litio en los procesos de adhesi&oacute;n a un sustrato resinoso. Con el resultado se pretende dar un sustento cient&iacute;fico al proceso del grabado de la superficie de restauraciones en disilicato de litio con &aacute;cido fluorh&iacute;drico. </p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>M&Eacute;TODOS</b></font></p>      <p>Se confeccionaron 6 cubos de porcelana de 10 x 10 mm (&plusmn; 0,2 mm) en cer&aacute;mica IPS e-max&reg; Press, por medio de la t&eacute;cnica de cera perdida siguiendo las indicaciones de la casa fabricante Ivoclar Vivadent&trade;<sup>13</sup>. Las muestras se revistieron con material refractario Emax Press Speed, en una proporci&oacute;n de 32 ml de l&iacute;quido especial por 22 ml de agua destilada y 200 gr de polvo, haciendo un mezclado al vac&iacute;o con el equipo Easy Mix de la casa Bego por 90 s. Los anillos, despu&eacute;s de un tiempo de fraguado de 45 min, se llevaron al horno a una temperatura de 850&deg; C por 60 min. La inyecci&oacute;n se hizo en el horno Programat EP5000 a una temperatura de 915&deg; C. Cada muestra fue arenada con part&iacute;culas de &oacute;xido de aluminio a dos bares (30 psi) de presi&oacute;n durante un tiempo aproximado de 14 s y a una distancia de 10 mm.<sup>9</sup></p>      <p>Se hicieron 6 cubos de resina Filtek&reg; Z250 con las mismas dimensiones, utilizando t&eacute;cnica incremental con per&iacute;odos de 20 s de polimerizaci&oacute;n. A cada cubo se le hicieron dos pesta&ntilde;as de fijaci&oacute;n en resina para el posicionamiento en el momento de los cortes. Todas las muestras fueron finalmente vaporizadas con la ayuda de la m&aacute;quina vap 6<sup>a</sup>, de la casa Zhermack para retirar residuos finales<sup>13</sup> (<a href="#t1">tabla 1</a> y <a href="#f1">figura 1</a>).</p>     <p align="center"><a name="t1"><img src="/img/revistas/rfoua/v26n1/v26n1a05t1.jpg"></a> </p>      <p align="center"><a name="f1"><img src="/img/revistas/rfoua/v26n1/v26n1a05f1.jpg"></a> </p>        <p>Cada cubo de cer&aacute;mica fue sometido a un tratamiento de superficie de acuerdo con la concentraci&oacute;n de &aacute;cido fluorh&iacute;drico y con el tiempo de exposici&oacute;n, creando 6 grupos a evaluar: El grupo I (grupo control) utiliz&oacute; &aacute;cido fluorh&iacute;drico IPS Ceramic Etching Gel al 4,6% durante 20 s (IPS-20). En los grupos II y III de investigaci&oacute;n, se emple&oacute; la misma concentraci&oacute;n del &aacute;cido, con unos tiempos de aplicaci&oacute;n de 40 s (IPS-40) y de 60 s (IPS-60). En el grupo IV, V y VI, se aplic&oacute; &aacute;cido fluorh&iacute;drico Eufar&reg; al 9,6% por 20 s (Eufar-20), 40 s (Eufar-40) y 60 s (Eufar-60), respectivamente (<a href="#t2">tabla 2</a>).</p>     <p align="center"><a name="t2"><img src="/img/revistas/rfoua/v26n1/v26n1a05t2.jpg"></a> </p>       <p>Posterior al protocolo de grabado &aacute;cido, cada muestra fue lavada con abundante agua durante 30 s, se le aplic&oacute; Silano Monobond-S&reg;, Ivoclar Vivadent&reg; utilizando un pincel desechable, y se dej&oacute; secar al aire siguiendo las instrucciones del fabricante.</p>      ]]></body>
<body><![CDATA[<p>Los cubos de porcelana se cementaron a los cubos de resina utilizando cemento resinoso autoadhesivo (Relyx U100&reg;, 3M-Espe), el cual es de uso rutinario en este tipo de restauraciones.<sup>14-16</sup> Este material fue preparado seg&uacute;n las indicaciones del fabricante, y con la ayuda de una esp&aacute;tula pl&aacute;stica se llev&oacute; a la superficie de adhesi&oacute;n.<sup>17</sup> Se mantuvieron las muestras en posici&oacute;n utilizando presi&oacute;n digital y se polimerizaron con una fuente de luz de intensidad de luz de 1100 a 1250 mW/cm2. La manipulaci&oacute;n y tiempo de polimerizaci&oacute;n fue de 40 s cada 90&deg; en la interface de adhesi&oacute;n disilicato de litio-resina. La estandarizaci&oacute;n intraoperador e interoperador, se hizo para los procesos de elaboraci&oacute;n y cementaci&oacute;n de muestras.</p>      <p>Cada una de las muestras fue llevada a almacenamiento por 1 h al aire libre y 23 h en agua destilada a 37&deg; C. Se hizo termociclaje de las muestras a 5,000 ciclos, con cambios de temperatura de 5 a 55&deg; C, en un tiempo de 30 s y con un tiempo de transferencia de 2 s aproximadamente.</p>      <p>Los cubos resultantes se seccionaron de forma perpendicular al agente cementante, con un disco diamantado de 0,22 mm de espesor, con la Cortadora Buehler Isomet 1000 Precision, con una velocidad de corte de 250 RPM y un contrapeso de 200 g (<a href="#f2">figura 2</a>), generando barras de 1 x 1 x 18 mm, (&plusmn; 0,3 mm). Cada una de las barras fue medida con un calibrador digital Mutitoyo para estandarizar las muestras y, posteriormente, determinar la fuerza por unidad de &aacute;rea necesaria para la falla en la prueba de adhesi&oacute;n. Los valores de adhesi&oacute;n se obtuvieron por medio de una prueba de microesfuerzo tensil, con las barras de 1 x 1 x 18 mm, con el objetivo de disminuir la probabilidad de encontrar un defecto en la interfase de adhesi&oacute;n y, por lo tanto, una reducci&oacute;n en su resistencia. Est&aacute; demostrado que el &aacute;rea o interfase de adhesi&oacute;n modifica la resistencia tensil, a menor &aacute;rea, mayor confiabilidad en la prueba.<sup>18- 21</sup></p>     <p align="center"><a name="f2"><img src="/img/revistas/rfoua/v26n1/v26n1a05f2.jpg"></a> </p>       <p>Luego de hechos los cortes, en cada grupo se seleccionaron al azar 20 muestras de cada uno de ellos, quedando un total de 120 muestras para ser evaluadas (<a href="#f3">figura 3</a>).</p>     <p align="center"><a name="f3"><img src="/img/revistas/rfoua/v26n1/v26n1a05f3.jpg"></a> </p>       <p>La m&aacute;quina universal de ensayos fue calibrada utilizando 20 muestras adicionales como prueba piloto. Las muestras fueron sometidas a carga en la m&aacute;quina universal de ensayos Instron&trade;, modelo 2519-105, con capacidad de 50 Newtons, donde se prob&oacute; la fuerza adhesiva. Se us&oacute; una velocidad de carga de 10 mm/min y se registr&oacute; la adhesi&oacute;n al disilicato de litio con fuerzas de tracci&oacute;n sobre el mismo eje axial de la barra, hasta lograr cualquier tipo de falla reportada en la curva de esfuerzo/deformaci&oacute;n (<a href="#f4">figuras 4</a> y <a href="#f5">5</a>).</p>     <p align="center"><a name="f4"><img src="/img/revistas/rfoua/v26n1/v26n1a05f4.jpg"></a> </p>      <p align="center"><a name="f5"><img src="/img/revistas/rfoua/v26n1/v26n1a05f5.jpg"></a> </p>       <p>La fuerza de ruptura fue medida en Newton, luego dividida por una secci&oacute;n transversal del &aacute;rea de cada muestra y luego expresada en Mega Pascales (MPa).<sup>11</sup> Donde la adhesi&oacute;n en MPa = P/A, donde P es la m&aacute;xima fuerza (N) y A es el &aacute;rea de cada muestra (mm<sup>2</sup>).<sup>5</sup></p>      ]]></body>
<body><![CDATA[<p>El an&aacute;lisis de los datos estad&iacute;sticos se hizo con el programa SPSS versi&oacute;n 19. Los datos se expresaron en promedio con su respectiva desviaci&oacute;n est&aacute;ndar (variables con distribuci&oacute;n normal seg&uacute;n la prueba de Kolmogorov- Smirnov). Se hicieron comparaciones aplicando un an&aacute;lisis de varianza ANOVA de una v&iacute;a, y se consider&oacute;, en el caso de que al aplicar esta prueba, la P fuera &gt; 0,05, se hiciera un an&aacute;lisis Post Hoc.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>      <p>Los valores de adhesi&oacute;n en cada grupo de investigaci&oacute;n obtenidos a partir de la prueba de micro esfuerzo tensil hasta la falla, se presentan en la <a href="#t3">tabla 3</a> y en la <a href="#f6">figura 6</a>.</p>     <p align="center"><a name="t3"><img src="/img/revistas/rfoua/v26n1/v26n1a05t3.jpg"></a> </p>      <p align="center"><a name="f6"><img src="/img/revistas/rfoua/v26n1/v26n1a05f6.jpg"></a> </p>       <p>Se encontr&oacute; que los promedios de resistencia adhesiva y su desviaci&oacute;n est&aacute;ndar fueron para el grupo control (IPS 20) de 26,69 (&plusmn; 7,99) Mpa. El grupo IPS 40 obtuvo un valor de 23,93 (&plusmn; 8,08) Mpa. El promedio de adhesi&oacute;n en el grupo IPS 60 fue de 20,9 (&plusmn; 7,91) Mpa. La resistencia adhesiva en los grupos Eufar 20, Eufar 40 y Eufar 60 fue de 17,56 (&plusmn; 6,61) Mpa, 16,30 (&plusmn; 11,68) Mpa y 18,78 (&plusmn; 10,22) Mpa respectivamente.</p>      <p>Al hacer el an&aacute;lisis de varianza Anova de una v&iacute;a, se puede considerar que al menos uno de los grupos genera diferencias significativas con relaci&oacute;n a la fuerza de adhesi&oacute;n del disilicato de litio, debido a que el valor de P obtenido (0,02) se encontr&oacute; por debajo de 0,05. Debido a esto, se hizo un an&aacute;lisis Post Hoc para evaluar las diferencias que se presentan entre los grupos. Los resultados se especifican en la <a href="#t4">tabla 4</a>.</p>     <p align="center"><a name="t4"><img src="/img/revistas/rfoua/v26n1/v26n1a05t4.jpg"></a> </p>        <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>       <p>Se han descrito diversos m&eacute;todos para medir la fuerza de adhesi&oacute;n de las superficies cer&aacute;micas a bloques de resina de manera in-vitro. Estos incluyen las pruebas de resistencia a la tensi&oacute;n y a las fuerzas de cizallamiento. Para estas &uacute;ltimas, a pesar de ser las m&aacute;s utilizadas para este tipo de estudios, se cuestiona su confiabilidad porque no siempre representan los verdaderos esfuerzos que se generan en la interface de adhesi&oacute;n cer&aacute;micaresina. <sup>22, 23</sup> Della Bona y Van Noort<sup>23</sup> observaron que la fuerza de adhesi&oacute;n en la uni&oacute;n cer&aacute;mica-resina, est&aacute; dada por la resistencia cohesiva del material cer&aacute;mico cuando es medida por fuerzas de cizallamiento; esto, debido a la gran concentraci&oacute;n de esfuerzos en este material en el sitio de aplicaci&oacute;n de la fuerza, lo cual genera una falla cohesiva a valores muy bajos de compresi&oacute;n. Por otro lado, las pruebas de resistencia a la tensi&oacute;n brindan datos m&aacute;s representativos de fuerza de adhesi&oacute;n en el &aacute;rea de uni&oacute;n, evidenciando un aumento de fallas adhesivas en las mediciones.</p>      <p>Sano y colaboradores<sup>18</sup> desarrollaron la t&eacute;cnica de resistencia de adhesi&oacute;n a los microesfuerzos tensiles, con el &aacute;nimo de evaluar la fuerza de uni&oacute;n en peque&ntilde;as &aacute;reas adheridas. Los autores demostraron que, en la medida en que se usaran &aacute;reas de adhesi&oacute;n m&aacute;s peque&ntilde;as, las fuerzas de uni&oacute;n que se observaban en la resistencia a la tensi&oacute;n, aumentaban.</p>      <p>En nuestro estudio, el rango de los valores de adhesi&oacute;n que se obtuvo se encuentra en el rango reportado por la gran mayor&iacute;a de autores en la literatura con esta t&eacute;cnica. Spohr en 2003,<sup>8</sup> Meyer en 2004<sup>9</sup> y Pollington en 2010,<sup>11</sup> utilizando la prueba de resistencia a los microesfuerzos tensiles, lograron valores similares de adhesi&oacute;n, usando diversos protocolos de acondicionamiento cer&aacute;mico en disilicato de litio.</p>      <p>Los resultados de nuestra investigaci&oacute;n sugieren que el acondicionamiento de superficie del disilicato de litio, con una concentraci&oacute;n de &aacute;cido fluorh&iacute;drico al 4,6% durante 20 s, como grupo control, mostr&oacute; el mejor comportamiento, con un promedio de 26,69 (&plusmn; 7,99) MPa de adhesi&oacute;n a un sustrato resinoso. Este valor present&oacute; diferencias significativas con el grupo 4, con una discrepancia de 9,14 MPa y un valor de P &le; 0,05 (0,004), al igual que con el grupo 5, con el cual present&oacute; una diferencia de 10,39 MPa y P &gt; 0,026. En los otros grupos, la concentraci&oacute;n y el tiempo de aplicaci&oacute;n del &aacute;cido fluorh&iacute;drico, no afect&oacute; significativamente la resistencia adhesiva en la prueba de micro esfuerzo tensil hecha en este estudio.</p>      <p>Existen numerosas t&eacute;cnicas que buscan mejorar los valores de resistencia adhesiva de la cer&aacute;mica a su sustrato. Blatz y colaboradores,<sup>2</sup> en su revisi&oacute;n de literatura en 2003, reportan que el alto contenido de fase cristalina del disilicato de litio podr&iacute;a expresarse en mayores valores de adhesi&oacute;n que la leucita o la cer&aacute;mica feldesp&aacute;tica, independientemente del acondicionamiento de superficie a los cuales sean sometidos estos materiales. Esto podr&iacute;a explicar los resultados similares obtenidos en los grupos, sin diferencia significativa en la mayor&iacute;a de ellos, independientemente del acondicionamiento de superficie hecho en este estudio.</p>      <p>Otros estudios, como los de Kiyan y colaboradores en 2007,<sup>7</sup> G&ouml;k&ccedil;e y colaboradores en 2007<sup>10</sup> y Kim y colaboradores en 2005,<sup>12</sup> a pesar de utilizar t&eacute;cnicas convencionales de resistencia a la tensi&oacute;n, confirman el efecto que tiene la concentraci&oacute;n y el tiempo de aplicaci&oacute;n del &aacute;cido fluorh&iacute;drico en los valores de adhesi&oacute;n a un sustrato resinoso. En donde, a mayor concentraci&oacute;n y tiempo de aplicaci&oacute;n, hay una tendencia a disminuir los valores de adhesi&oacute;n en este tipo de materiales.</p>      <p>Nuestro estudio demostr&oacute; que el grabado con &aacute;cido fluorh&iacute;drico al 4,6%, durante 20 s, obtiene los mejores resultados con relaci&oacute;n a la fuerza adhesiva del disilicato de litio, seguido por la misma concentraci&oacute;n, pero con un tiempo de aplicaci&oacute;n de 40 y de 60 s. Tambi&eacute;n se evidenci&oacute; disminuci&oacute;n en los valores de adhesi&oacute;n, cuando se aument&oacute; la concentraci&oacute;n y el tiempo de aplicaci&oacute;n del agente grabador.</p>      <p>Los resultados obtenidos ofrecen pautas cl&iacute;nicas para considerar durante el proceso de cementaci&oacute;n de las restauraciones en disilicato de litio. Los valores m&aacute;ximos de adhesi&oacute;n, confirman al grabado de la superficie en disilicato de litio con &aacute;cido fluorh&iacute;drico al 4,6% durante 20 s y la aplicaci&oacute;n del silano, como la regla de oro en la adhesi&oacute;n de este tipo de restauraciones.</p>      <p>Se sugiere hacer futuros trabajos que correlacionen los valores de adhesi&oacute;n obtenidos por pruebas de microesfuerzo tensil del disilicato de litio adherido a un sustrato resinoso, y las caracter&iacute;sticas superficiales del material observados en un microscopio electr&oacute;nico de barrido, para encontrar una mayor fundamentaci&oacute;n del efecto que tiene la concentraci&oacute;n y el tiempo de aplicaci&oacute;n sobre los valores de adhesi&oacute;n en restauraciones hechas en disilicato de litio y cementadas con materiales resinosos.</p>        ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>Con las limitaciones de este estudio, podemos concluir que:</p>        <p>Los mayores promedios de fuerza adhesiva del disilicato de litio, unido a un sustrato resinoso, se obtuvieron en los grupos que fueron acondicionados con el &aacute;cido fluorh&iacute;drico al 4,6%, en comparaci&oacute;n con los grabados al 9,6%.</p>      <p>Los valores promedios de resistencia adhesiva que se obtuvieron en nuestro estudio, pueden representar valores cl&iacute;nicamente aceptables para un buen desempe&ntilde;o cl&iacute;nico seg&uacute;n estudios previos.</p>       <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONFLICTOS DE INTER&Eacute;S</b></font></p>      <P>Los autores declaran no tener conflictos de inter&eacute;s.</P>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>       ]]></body>
<body><![CDATA[<!-- ref --><p>1. Guess PC, Schultheis S, Bonfante EA, Coelho PG, Ferencz JL, Silva NR. All-ceramic systems: laboratory and clinical performance. Dent Clin North Am 2011; 55(2): 333-352.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S0121-246X201400020000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>2. Blatz MB, Sadan A, Kern M. Resin-ceramic bonding: a review of the literature. J Prosthet Dent 2003; 89(3): 268- 274.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0121-246X201400020000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>3. Manso AP, Silva NR, Bonfante EA, Pegoraro TA, Dias RA, Carvalho RM. Cements and adhesives for all-ceramic restorations. Dent Clin North Am 2011; 55(2): 311-332.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0121-246X201400020000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>4. Valandro LF, Della Bona A, Bottino MA, Neisser MP. The effect of ceramic surface treatment on bonding to densely sintered alumina ceramic. J Prosthet Dent 2005; 93(3): 253-259.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0121-246X201400020000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>5. Zortuk M, K Kilic, Gurbulak AG, Kesim B, Uctasli S. Tensile bond strength of a lithium-disilicate pressed glass ceramic to dentin of different surface treatments. Dent Mater J 2010; 29(4): 418-424.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0121-246X201400020000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>6. Della Bona A, Anusavice KJ, Mecholsky JJ Jr. Failure analysis of resin composite bonded to ceramic. Dent Mater 2003; 19(8): 693-699.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0121-246X201400020000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>7. Kiyan VH, Saraceni CH, Silveira BL, Aranha AC, Eduardo CP. The influence of internal surface treatments on tensile bond strength for two ceramic systems. Oper Dent 2007; 32(5): 457-465.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0121-246X201400020000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>8. Spohr AM, Sobrinho LC, Consani S, Sinhoreti MA, Knowles JC. Influence of surface conditions and silane agent on the bond of resin to IPS Empress 2 ceramic. Int J Prosthodont 2003; 16(3): 277-282.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0121-246X201400020000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>9. Meyer FA, Clovis CL. Effect of different ceramic surface treatments on resin microtensile bond strength. J Prosthodont 2004; 13(1): 28-35.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0121-246X201400020000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>10. G&ouml;k&ccedil;e B, &Ouml;zpinar B, D&uuml;ndar M, &Ccedil;&ouml;mlekoglu E, Sen BH, G&uuml;ng&ouml;r MA. Bond strengths of all-ceramics: acid vs laser etching. Oper Dent 2007; 32(2): 173-178.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0121-246X201400020000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>11. Pollington S, Fabianelli A, Van Noort R. Microtensile bond strength of a resin cement to a novel fluorcanasite glass-ceramic following different surface treatments. Dent Mater 2010; 26(9): 864-872.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0121-246X201400020000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>12. Kim BK, Bae HE, Shim JS, Lee KW. The influence of ceramic surface treatments on the tensile bond strength of composite resin to all-ceramic coping materials. J Prosthet Dent 2005; 94(4): 357-362.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0121-246X201400020000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>13. Brentel AS, Ozcan M, Valandro LF, Alar&ccedil;a LG, Amaral R, Bottino MA. Microtensile bond strength of a resin cement to feldpathic ceramic after different etching and silanization regimens in dry and aged conditions. Dent Mater 2007; 23(11): 1323-1331.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X201400020000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>14. Hooshmand T, Van Noort R, Keshvad A. Bond durability of the resin-bonded and silane treated ceramic surface. Dent Mater 2002; 18(2): 179-188.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X201400020000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>15. Matinlinna JP, Vallittu PK. Bonding of resin composites to etchable ceramic surfaces -an insight review of the chemical aspects on surface conditioning. J Oral Rehab 2007; 34(8): 622-630.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X201400020000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>16. Aida M, Hayakawa T, Mizukawa K. Adhesion of composite to porcelain with various surface conditions. J Prosthet Dent 1995; 73(5): 464-470.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201400020000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>17. Kamada K, Yoshida K, Atsuta M. Effect of ceramic surface treatments on the bond of four resin luting agents to a ceramic material. J Prosthet Dent 1998; 79(5): 508-513.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X201400020000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>18. Sano H, Shono T, Sonoda H, Takatsu T, Ciucchi B, Carvalho R et al. Relationship between surface area for adhesion and tensile bond strength -evaluation of a micro-tensile bond test. Dent Mater 1994; 10(4): 236-240.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X201400020000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>19. Burrow MF, Thomas D, Swain MV, Tyas M J. Analysis of tensile bond strengths using Weibull statistics. Biomaterials 2004; 25(20): 5031-5035.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X201400020000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>20. Pashley DH, Carvalho RM, Sano H, Nakajima M, Yoshiyama M, Shono Y et al. The microtensile bond test: a review. J Adhes Dent 1999; 1(4): 299-309.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0121-246X201400020000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>21. Arias VG, Ambrosano GMB, Pimenta LAF. Determination of the sample and plot size for microtensile testing. J Dent Res 2006; 85: 8-18.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0121-246X201400020000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>22. Van Noort R, Noroozi S, Howard IC, Cardew G. A critique of bond strength measurements. J Dent 1989; 17(2): 61-67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0121-246X201400020000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>23. Della Bona A, Van Noort R. Shear vs. tensile bond strength of resin composite bonded to ceramic. J Dent Res 1995; 74(9): 1591-1596.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0121-246X201400020000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p> </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guess]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Schultheis]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bonfante]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Coelho]]></surname>
<given-names><![CDATA[PG]]></given-names>
</name>
<name>
<surname><![CDATA[Ferencz]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[NR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[All-ceramic systems: laboratory and clinical performance]]></article-title>
<source><![CDATA[Dent Clin North Am]]></source>
<year>2011</year>
<volume>55</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>333-352</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Blatz]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Sadan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kern]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resin-ceramic bonding: a review of the literature]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2003</year>
<volume>89</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>268- 274</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manso]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[NR]]></given-names>
</name>
<name>
<surname><![CDATA[Bonfante]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Pegoraro]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
<name>
<surname><![CDATA[Dias]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cements and adhesives for all-ceramic restorations]]></article-title>
<source><![CDATA[Dent Clin North Am]]></source>
<year>2011</year>
<volume>55</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>311-332</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valandro]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Della]]></surname>
<given-names><![CDATA[Bona A]]></given-names>
</name>
<name>
<surname><![CDATA[Bottino]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Neisser]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of ceramic surface treatment on bonding to densely sintered alumina ceramic]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2005</year>
<volume>93</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>253-259</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zortuk]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[K]]></surname>
<given-names><![CDATA[Kilic]]></given-names>
</name>
<name>
<surname><![CDATA[Gurbulak]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Kesim]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Uctasli]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tensile bond strength of a lithium-disilicate pressed glass ceramic to dentin of different surface treatments]]></article-title>
<source><![CDATA[Dent Mater. J]]></source>
<year>2010</year>
<volume>29</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>418-424</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Della]]></surname>
<given-names><![CDATA[Bona A]]></given-names>
</name>
<name>
<surname><![CDATA[Anusavice]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mecholsky]]></surname>
<given-names><![CDATA[JJ Jr]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Failure analysis of resin composite bonded to ceramic]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2003</year>
<volume>19</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>693-699</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kiyan]]></surname>
<given-names><![CDATA[VH]]></given-names>
</name>
<name>
<surname><![CDATA[Saraceni]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Silveira]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Aranha]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Eduardo]]></surname>
<given-names><![CDATA[CP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of internal surface treatments on tensile bond strength for two ceramic systems]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2007</year>
<volume>32</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>457-465</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Spohr]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Sobrinho]]></surname>
<given-names><![CDATA[LC]]></given-names>
</name>
<name>
<surname><![CDATA[Consani]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sinhoreti]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Knowles]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of surface conditions and silane agent on the bond of resin to IPS Empress 2 ceramic]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2003</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>277-282</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Meyer]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Clovis]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of different ceramic surface treatments on resin microtensile bond strength]]></article-title>
<source><![CDATA[J Prosthodont]]></source>
<year>2004</year>
<volume>13</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>28-35</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gökçe]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Özpinar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Dündar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Çömlekoglu]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sen]]></surname>
<given-names><![CDATA[BH]]></given-names>
</name>
<name>
<surname><![CDATA[Güngör]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bond strengths of all-ceramics: acid vs laser etching]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2007</year>
<volume>32</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>173-178</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pollington]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fabianelli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Van-Noort]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microtensile bond strength of a resin cement to a novel fluorcanasite glass-ceramic following different surface treatments]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2010</year>
<volume>26</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>864-872</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[BK]]></given-names>
</name>
<name>
<surname><![CDATA[Bae]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Shim]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[KW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of ceramic surface treatments on the tensile bond strength of composite resin to all-ceramic coping materials]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2005</year>
<volume>94</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>357-362</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brentel]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Ozcan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Valandro]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Alarça]]></surname>
<given-names><![CDATA[LG]]></given-names>
</name>
<name>
<surname><![CDATA[Amaral]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bottino]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microtensile bond strength of a resin cement to feldpathic ceramic after different etching and silanization regimens in dry and aged conditions]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2007</year>
<volume>23</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1323-1331</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hooshmand]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Van Noort]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Keshvad]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bond durability of the resin-bonded and silane treated ceramic surface]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2002</year>
<volume>18</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>179-188</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matinlinna]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Vallittu]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bonding of resin composites to etchable ceramic surfaces -an insight review of the chemical aspects on surface conditioning]]></article-title>
<source><![CDATA[J Oral Rehab]]></source>
<year>2007</year>
<volume>34</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>622-630</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aida]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hayakawa]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Mizukawa]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adhesion of composite to porcelain with various surface conditions]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1995</year>
<volume>73</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>464-470</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kamada]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshida]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Atsuta]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of ceramic surface treatments on the bond of four resin luting agents to a ceramic material]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1998</year>
<volume>79</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>508-513</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sano]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shono]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Sonoda]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Takatsu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ciucchi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Relationship between surface area for adhesion and tensile bond strength -evaluation of a micro-tensile bond test]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>1994</year>
<volume>10</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>236-240</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burrow]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Thomas]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Swain]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
<name>
<surname><![CDATA[Tyas]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of tensile bond strengths using Weibull statistics]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2004</year>
<volume>25</volume>
<numero>20</numero>
<issue>20</issue>
<page-range>5031-5035</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pashley]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Sano]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Nakajima]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshiyama]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Shono]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The microtensile bond test: a review]]></article-title>
<source><![CDATA[J Adhes Dent]]></source>
<year>1999</year>
<volume>1</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>299-309</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arias]]></surname>
<given-names><![CDATA[VG]]></given-names>
</name>
<name>
<surname><![CDATA[Ambrosano]]></surname>
<given-names><![CDATA[GMB]]></given-names>
</name>
<name>
<surname><![CDATA[Pimenta]]></surname>
<given-names><![CDATA[LAF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of the sample and plot size for microtensile testing]]></article-title>
<source><![CDATA[J Dent Res]]></source>
<year>2006</year>
<volume>85</volume>
<page-range>8-18</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van]]></surname>
<given-names><![CDATA[Noort R]]></given-names>
</name>
<name>
<surname><![CDATA[Noroozi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Howard]]></surname>
<given-names><![CDATA[IC]]></given-names>
</name>
<name>
<surname><![CDATA[Cardew]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A critique of bond strength measurements]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>1989</year>
<volume>17</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>61-67</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Della]]></surname>
<given-names><![CDATA[Bona A]]></given-names>
</name>
<name>
<surname><![CDATA[Van-Noort]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Shear vs. tensile bond strength of resin composite bonded to ceramic]]></article-title>
<source><![CDATA[J Dent Res]]></source>
<year>1995</year>
<volume>74</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1591-1596</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
