<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-3709</journal-id>
<journal-title><![CDATA[ORINOQUIA]]></journal-title>
<abbrev-journal-title><![CDATA[Orinoquia]]></abbrev-journal-title>
<issn>0121-3709</issn>
<publisher>
<publisher-name><![CDATA[Instituto de Investigaciones de la Orinoquia Colombiana]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-37092020000200099</article-id>
<article-id pub-id-type="doi">10.22579/20112629.633</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Biodegradabilidad de lixiviados procedentes de un relleno sanitario utilizando un sistema de lodos activados flujo pistón]]></article-title>
<article-title xml:lang="en"><![CDATA[The biodegradability of leachates from a landfill using an activated sludge processes plug flow reactor system]]></article-title>
<article-title xml:lang="pt"><![CDATA[Biodegradabilidade de lixiviados de um aterro usando um sistema de lodos ativados de fluxo de pistão]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rosas-Vargas]]></surname>
<given-names><![CDATA[Jenny A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ramón-Valencia]]></surname>
<given-names><![CDATA[Jacipt A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad de Pamplona  ]]></institution>
<addr-line><![CDATA[ Pamplona]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad de Pamplona Facultad de Ingenierías y Arquitectura ]]></institution>
<addr-line><![CDATA[ Pamplona]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2020</year>
</pub-date>
<volume>24</volume>
<numero>2</numero>
<fpage>99</fpage>
<lpage>109</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-37092020000200099&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-37092020000200099&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-37092020000200099&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen En esta investigación se desarrolló un Reactor Flujo Pistón (RFP) de lodos activados, que fue empleado para determinar el Tiempo de Retención Celular (TRC) óptimo para tratar cargas altas de lixiviado y estimar el comportamiento cinético del sistema con el fin que sirva de base para proyecciones de escalamiento y diseño de reactor de este tipo a escala real. Para ello se realizó el diseño, la construcción y puesta en marcha del RFP a nivel de laboratorio (capacidad de 50L) en condiciones de operación continua con recirculación de lodo y se utilizó como sustrato lixiviado procedente del relleno sanitario El Guayabal de la ciudad de Cúcuta. Se determinó como parámetros de control cuatro TRC diferentes entre 5 y 20 días diferenciada por etapas. Se evaluaron las variables de pH, Temperatura, Oxígeno disuelto y Sólidos Suspendidos Volátiles en el Licor Mixto (SSVLM). En cuanto al control y monitoreo de la eficiencia de remoción se escogió la Demanda Química de Oxígeno (DQO) como parámetro para medir la degradación de materia orgánica, dado que este parámetro a diferencia de la Demanda Bioquímica de Oxígeno (DBO5) puede ser calculado en un menor tiempo. El sistema biológico RFP alcanzó estabilizarse en un período de operación entre 20 y 25 días con remociones promedio mayores a 92% para TRC de 15 y 20 días mientras que TRC menores reportaron remociones promedio por debajo del 86%. Así mismo TRC de 15 permitió un Factor de carga (F/M) óptima promedio de 1.1 KgDQO/KgSSV.d. Las constantes cinéticas obtenidas en esta investigación, representativas para un sistema de RFP operado a escala laboratorio para remoción de materia orgánica carbonacea en lixiviados fueron: KS= 836.5 mg/L DQO, k=4.8123 d1, Y= 0.089 mg SSVLM/mg DQO y kd= 0.018 d-1, ajustados por regresión al modelo matemático de Lawrence y McCarty al poseer una correlación de 0.97 entre los datos experimentales obtenidos y el modelo y amplia aplicación en el campo de diseño de reactores de lodos activados.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract An activated sludge processes (ASP) plug flow reactor (PFR) was developed in this research and used for determining optimal cell residence time (CRT) for treating high leachate loads and estimating the system&#8217;s kinetic behaviour as a basis for scaling projections and this type of reactor design at full-scale. The RFP was designed, built and put into operation in the laboratory (50L capacity) involving continuous operation conditions with sludge recirculation; leached substrate from the city of Cúcuta&#8217;s El Guayabal landfill was used. Four 5-day CRTs (ranging from 5 to 20 days) were used as control parameters. Variables were evaluated regarding pH, temperature, dissolved oxygen and mixed liquor volatile suspended solids (MLVSS). Regarding removal efficiency control and monitoring, chemical oxygen demand (COD) was chosen as a parameter for measuring organic matter degradation since COD (unlike biochemical oxygen demand (BOD5)) can be calculated in a shorter time. The RFP biological system became stabilised in a 20- to 25-day operating period, having greater than 92% average removal for 15- and 20-day CRTs, whilst lower CRTs reported lower than 86% average removal. A 15-day TRC gave an average 0.26 kgDQO/kgSSV.d optimal load factor (F/M). The representative kinetic constants obtained in this research for a laboratory-scale PFR system for the removal of carbonaceous organic matter in leachates were KS = 836mg COD / l, k = 4.8123 d1, Y = 0.089 mg SSVLM / mg COD and kd = 0.018 d-1, adjusted by regression using Lawrence and McCarty&#8217;s mathematical model (having 0.97 correlation between the experimental data and the model). Such model should have broad application in the field of ASP-type PFRs.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Resumo Nesta pesquisa, um Reator de lodo ativado de Fluxo de Pistão (RFP) foi desenvolvido para determinar o Tempo de Retenção Celular (CRT) ideal para tratar altas cargas de lixiviado e estimar o comportamento cinético do sistema, a fim de servir de base para projetar o reator em escala real. Para isso, foram realizados RFP em nível de laboratório (capacidade de 50L) em condições de operação contínua com recirculação de lodo e foi utilizada como substrato lixiviado do aterro El Guayabal na cidade de Cúcuta. Usando quatro diferentes CRTs entre 5 e 20 dias como fatores de bloqueio. Foram avaliadas as variáveis &#8203;&#8203;pH, Temperatura, Oxigênio Dissolvido e Sólidos Suspensos Voláteis no Licor Misto (SSVLM). Em relação ao controle e monitoramento da eficiência de remoção, a Demanda Química de Oxigênio (DQO) foi escolhida como parâmetro para medir a degradação da matéria orgânica, uma vez que este parâmetro, ao contrário da Demanda Bioquímica de Oxigênio (DBO5), pode ser calculado em um tempo mais curto. O sistema biológico da RFP se estabilizou em um período de operação entre 20 e 25 dias com remoções médias superiores a 92% para TRC de 15 e 20 dias, enquanto TRC menores mostraram remoções médias abaixo de 86%. Da mesma forma, TRC de 15 dias permitiu um fator de carga ideal médio (F / M) de 0,26 KgDQO / d. As constantes cinéticas obtidas nesta pesquisa, representativas de um sistema RFP operado em escala de laboratório para remoção de matéria orgânica carbonácea em lixiviados foram: KS = 836mg COD / l, k = 4,8123 d1, Y = 0,089 mg SSVLM / mg COD e kd = 0,018 d-1, ajustado por regressão ao modelo matemático de Lawrence e McCarty, tendo uma correlação de 0,97 entre os dados experimentais obtidos e o modelo e ampla aplicação na área de projeto de reatores de lodo ativado.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[factor de carga]]></kwd>
<kwd lng="es"><![CDATA[modelo matemático]]></kwd>
<kwd lng="es"><![CDATA[parámetros cinéticos]]></kwd>
<kwd lng="es"><![CDATA[reactor flujo pistón]]></kwd>
<kwd lng="es"><![CDATA[recirculación de lodos]]></kwd>
<kwd lng="es"><![CDATA[tiempo de residencia celular.]]></kwd>
<kwd lng="en"><![CDATA[load factor]]></kwd>
<kwd lng="en"><![CDATA[mathematical model]]></kwd>
<kwd lng="en"><![CDATA[kinetic parameter]]></kwd>
<kwd lng="en"><![CDATA[plug flow reactor]]></kwd>
<kwd lng="en"><![CDATA[sludge recirculation]]></kwd>
<kwd lng="en"><![CDATA[cell residence time.]]></kwd>
<kwd lng="pt"><![CDATA[fator de carga]]></kwd>
<kwd lng="pt"><![CDATA[modelo matemático]]></kwd>
<kwd lng="pt"><![CDATA[parâmetros cinéticos]]></kwd>
<kwd lng="pt"><![CDATA[reator de fluxo em pistão]]></kwd>
<kwd lng="pt"><![CDATA[recirculação de lodo]]></kwd>
<kwd lng="pt"><![CDATA[tempo de residência da célula.]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Álvarez]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Suárez]]></surname>
<given-names><![CDATA[GJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Tratamiento biológico del lixiviado generado en el relleno sanitario &#8220;El Guayabal&#8221; de la ciudad San José de Cúcuta]]></article-title>
<source><![CDATA[Revista Ingeniería y Desarrollo]]></source>
<year>2006</year>
<numero>20</numero>
<issue>20</issue>
<page-range>95-105</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="book">
<collab>APHA-American Public Health Association</collab>
<source><![CDATA[Métodos normalizados para el análisis de aguas potables y residuales]]></source>
<year>2005</year>
<edition>21</edition>
<publisher-loc><![CDATA[Madrid, España ]]></publisher-loc>
<publisher-name><![CDATA[APHA, AWWA, WPCF]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arévalo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ramón]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ramón]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Estimación cinética de los procesos biológico de lixiviados, a partir de un sistema experimental con humedales artificiales utilizando especies nativas]]></article-title>
<source><![CDATA[Revista de Tecnología]]></source>
<year>2015</year>
<volume>14</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>37-48</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arguadas]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Parámetros de control de un sistema biológico]]></source>
<year>2013</year>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Landeta]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Angulo]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Trujillo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Determination of kinetic constants for the design of biological treatment dairy effluent in batch system]]></article-title>
<source><![CDATA[Revista Técnica de la Facultad de Ingeniería]]></source>
<year>2014</year>
<volume>37</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>11-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chávez]]></surname>
<given-names><![CDATA[MW.]]></given-names>
</name>
</person-group>
<source><![CDATA[Tratamiento de lixiviados generados en el relleno sanitario de la Cd]]></source>
<year>2011</year>
<publisher-loc><![CDATA[de Chihuahua, México ]]></publisher-loc>
<publisher-name><![CDATA[CHIHUAHUA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mironel.]]></surname>
<given-names><![CDATA[Corena L]]></given-names>
</name>
</person-group>
<source><![CDATA[Sistemas de tratamientos para lixiviados generados en rellenos sanitarios]]></source>
<year>2008</year>
<page-range>104</page-range><publisher-loc><![CDATA[Sincelejo, Colombia ]]></publisher-loc>
<publisher-name><![CDATA[Universidad de Sucre Facultad de Ingeniería]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Espinosa-Rodríguez]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Flores-Ánamo]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Esparza-Soto]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fall]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Efecto de la temperatura en la tasa de crecimiento y decaimiento heterotrófico en el rango de 20-32°C en un proceso de lodos activados]]></article-title>
<source><![CDATA[Revista Mexicana De Ingeniería Química]]></source>
<year>2012</year>
<volume>11</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>309-32</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Giraldo]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Tratamiento De Lixiviados De Rellenos Sanitarios: Avances Recientes]]></article-title>
<source><![CDATA[Revista de Ingeniería Universidad de Los Andes]]></source>
<year>2011</year>
<publisher-loc><![CDATA[Bogotá, Colombia ]]></publisher-loc>
<publisher-name><![CDATA[Departamento de Ingeniería Civil y Ambiental]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Giraldo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<source><![CDATA[Arranque y operación de un reactor experimental de lodos activados para el tratamiento de aguas residuales urbanas]]></source>
<year>2003</year>
<publisher-loc><![CDATA[Manizales ]]></publisher-loc>
<publisher-name><![CDATA[Universidad Nacional de Colombia]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Postratamiento en escala piloto del lixiviado del relleno sanitario Antanas (Pasto-Nariño) por filtración-adsorción con arena, antracita y carbón activado]]></article-title>
<source><![CDATA[Revista de Ingeniería]]></source>
<year>2015</year>
<numero>43</numero>
<issue>43</issue>
<page-range>10-5</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<collab>Metcalf y Eddy Inc.</collab>
<source><![CDATA[Wastewater engineering treatment, disposal and reuse]]></source>
<year>2003</year>
<edition>4</edition>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orozco-Jaramillo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Bioingeniería de aguas residuales]]></article-title>
<source><![CDATA[Teoría y diseño]]></source>
<year>2014</year>
<edition>2</edition>
<page-range>136-1150</page-range><publisher-name><![CDATA[Editorial Acodal]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Control de la sedimentación de lodos y eliminación de nitrógeno en condiciones de bajo nivel de oxígeno disuelto]]></article-title>
<source><![CDATA[Sci. Ing.]]></source>
<year>2012</year>
<numero>6</numero>
<issue>6</issue>
<page-range>884-91</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[CE.]]></given-names>
</name>
</person-group>
<source><![CDATA[Fundamentos del proceso de lodos activados]]></source>
<year>2008</year>
<page-range>96</page-range><publisher-loc><![CDATA[México ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Universitaria]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramón]]></surname>
<given-names><![CDATA[VJL]]></given-names>
</name>
<name>
<surname><![CDATA[Ramón]]></surname>
<given-names><![CDATA[VJ]]></given-names>
</name>
<name>
<surname><![CDATA[Maldonado]]></surname>
<given-names><![CDATA[BO.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Software de simulación para el diseño de reactores de lodos activados]]></article-title>
<source><![CDATA[Revista Colombiana de Tecnologías de Avanzada]]></source>
<year>2016</year>
<volume>2</volume>
<numero>28</numero>
<issue>28</issue>
<page-range>74-7</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[VC.]]></given-names>
</name>
</person-group>
<source><![CDATA[Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domesticas generadas en el colegio San Viator]]></source>
<year>2017</year>
<publisher-loc><![CDATA[Bogotá, D.C, Colombia ]]></publisher-loc>
<publisher-name><![CDATA[Fundación Facultad De Ingenierías, Universidad De América Programa De Ingeniería Química]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Molina]]></surname>
<given-names><![CDATA[FJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Estrategias Operacionales para el Control de Problemas de Baja Sedimentación Causados por Bacterias Filamentosas en Plantas de Lodos Activados]]></article-title>
<source><![CDATA[Revista Científica en Ciencias Ambientales y Sostenibilidad (CAS)]]></source>
<year>2017</year>
<volume>4</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1-19</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Osorio]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio de la influencia del TRC sobre la reducción de materia orgánica carbonácea y nitrógeno en una nueva configuración del sistema de estabilización por contacto tratando agua residual doméstica]]></source>
<year>2014</year>
<page-range>93</page-range><publisher-loc><![CDATA[Colombia ]]></publisher-loc>
<publisher-name><![CDATA[Universidad del Valle, Santiago de Cali]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Romero]]></surname>
<given-names><![CDATA[RJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Tratamiento de aguas residuales]]></article-title>
<source><![CDATA[Teoría y principios de diseño]]></source>
<year>2005</year>
<edition>3</edition>
<publisher-loc><![CDATA[Bogotá, Colombia ]]></publisher-loc>
<publisher-name><![CDATA[Escuela Colombiana de Ingeniería]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[LP]]></given-names>
</name>
<name>
<surname><![CDATA[Barba Ho]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ojeda]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Martínez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Castaño]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Influencia de la edad de lixiviados sobre su composición físico-química y su potencial de toxicidad]]></article-title>
<source><![CDATA[Revista U.D.C.A Actualidad y Divulgación Científica]]></source>
<year>2014</year>
<volume>17</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>245-55</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[RJC]]></given-names>
</name>
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[VJA.]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseño, implementación y estudio hidrodinámico de un reactor biológico de cargas secuenciales de flujo a pistón para tratar aguas residuales sintéticas]]></source>
<year>2008</year>
</nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Von-Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Principios del Tratamiento Biológico de Aguas Residuales]]></article-title>
<source><![CDATA[Introducción a la calidad del agua y al tratamiento de aguas residuales]]></source>
<year>2012</year>
<volume>1</volume>
<edition>1</edition>
<page-range>468</page-range><publisher-loc><![CDATA[San Juan de Pasto ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Universitaria]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
