<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0122-9354</journal-id>
<journal-title><![CDATA[Revista de Medicina Veterinaria]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Med. Vet.]]></abbrev-journal-title>
<issn>0122-9354</issn>
<publisher>
<publisher-name><![CDATA[Universidad de La Salle]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0122-93542011000100002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Evaluación de la resistencia de un prototipo de placa de compresión dinámica (PCD) fabricada de polimetilmetacrilato (PMMA) probada en fémur canino osteotomizado]]></article-title>
<article-title xml:lang="en"><![CDATA[Assessment of the Resistance of a Polymethylmethacrylate (PMMA) Dynamic Compression Plate (DCP) Prototype Tested on Osteotomized Canine Femurs]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cardona R.]]></surname>
<given-names><![CDATA[Leonel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Brousse]]></surname>
<given-names><![CDATA[Mariana]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mieres]]></surname>
<given-names><![CDATA[Marcelo]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Arias]]></surname>
<given-names><![CDATA[Sergio]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[Édgar]]></given-names>
</name>
<xref ref-type="aff" rid="A05"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de La Salle centro de investigaciones CISAHE Unidad de Cirugía de pequeños animales]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Austral de Chile Instituto de Ciencias Clínicas Veterinarias ]]></institution>
<addr-line><![CDATA[Valdivia ]]></addr-line>
<country>Chile</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Austral de Chile Instituto de Ciencias Clínicas Veterinarias ]]></institution>
<addr-line><![CDATA[Valdivia ]]></addr-line>
<country>Chile</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad de La Salle centro de investigaciones CISAHE Unidad de Cirugía de pequeños animales]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A05">
<institution><![CDATA[,Universidad de La Salle centro de investigaciones CISAHE Unidad de Cirugía de pequeños animales]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<numero>21</numero>
<fpage>13</fpage>
<lpage>24</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0122-93542011000100002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0122-93542011000100002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0122-93542011000100002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Las fracturas de huesos largos encontradas más frecuentemente en animales pequeños son las del fémur. Por su posición anatómica, son difíciles de inmobilizar, entonces, la utilización de fijaciones internas es de gran utilidad. Las placas de compresión dinámica (PCD) proveen gran estabilidad, son durables y al producir compresión interfragmentaria, minimizan el movimiento fragmentario y promueven la cicatrización primaria del hueso. Sus ventajas están asociadas a la reconstrucción anatómica, movilidad temprana y capacidad de carga del miembro. El polimetilmetacrilato (PMMA) es una resina acrílica utilizada en prótesis dentales. Pero, estudios muestran otros usos, tratamientos de tumores óseos, prótesis en deformaciones craneales, vertebroplastias percutáneas y prótesis testiculares en animales, entre otros. El objetivo de este estudio fue fabricar PCD-PMMA y comprobar su resistencia a las distintas fuerzas que están presentes en una fractura. Se fabricaron 48 PCD de 3,5 milímetros de cuatro orificios a partir de un molde de alginato. Se obtuvieron seis fémures de cadáveres caninos de 10 a 20 kg de peso, a los cuales se les realizó una osteotomía que simulaba una fractura oblicua. Posteriormente, se posicionaron las placas en los huesos osteotomizados para someterlas a las distintas fuerzas que participan en una fractura. Las PCD-PMMA resistieron 2,83 newton/metro a la fuerza de torsión y 0,21 kilonewton a las fuerzas de compresión y flexión. La resistencia de la PCD-PMMA obtenida fue en promedio de 20 kg, a cada una de las fuerzas. Se pudo concluir que es posible fabricar una PCD-PMMA de 3,5 mm de cuatro orificios, cuya resistencia es de 20 kg de peso a las tres fuerzas aplicadas. Entonces, pueden ser utilizadas para la estabilización de fracturas de huesos largos que sean sometidos a una presión inferior a 20 kg de fuerza.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Femur fractures are the most frequent long bone fractures in small animals. Due to the femur's anatomical position, it is difficult to immobilize, and therefore internal fixations are very useful. Dynamic compression plates (DCP) provide high stability, are durable, minimize fragment movement and promote primary healing of the bone. Advantages of this treatment include anatomical reconstruction, early mobility and carrying capacity of the affected limb. Polymethylmethacrylate (PMMA) is an acrylic resin that has proved very useful in bone tumor treatment, cranial deformation prosthesis, percutaneous vertebroplasty and testicular prosthesis in animals. The purpose of this study was to manufacture DCP-PMMA and test its resistance to the different forces present in a fracture. Forty-eight (48) 3.5MM x 4-hole DCP were made from an alginate mold. Six (6) femurs were obtained from canine cadavers weighing from 10 to 20 kg, which underwent osteotomy simulating an oblique fracture. The plates were subsequently positioned in the osteotomized bones to submit them to the various forces involved in a fracture. The DCP-PMMA resisted a torque force of 2.83 newton/metres and a compression and flexion force of 0.21 kilonewton. The obtained resistance of the DCP-PMMA was an average of 20 kg per force. The results of this study show that it is possible to make a DCP-PMMA 3.5 mm x 4-hole, the resistance of which is of 20 kg against the three applied forces, and that it can be used to stabilize long bone fractures subjected to a pressure of less than 20 kg.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[placa compresión dinámica]]></kwd>
<kwd lng="es"><![CDATA[polimetilmetacrilato]]></kwd>
<kwd lng="es"><![CDATA[fractura]]></kwd>
<kwd lng="en"><![CDATA[dynamic compression plate]]></kwd>
<kwd lng="en"><![CDATA[polymethylmethacrylate]]></kwd>
<kwd lng="en"><![CDATA[fracture]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font face="verdana" size="2">      <br><font size="4">     <p align="center"><b>Evaluaci&oacute;n de la resistencia de un prototipo    <br> de placa de compresi&oacute;n din&aacute;mica (PCD)    <br> fabricada de polimetilmetacrilato (PMMA) probada    <br> en f&eacute;mur canino osteotomizado</b></p></font>  <font size="3">     <p align="center"><b>Assessment of the Resistance of a Polymethylmethacrylate    <br> (PMMA) Dynamic Compression Plate (DCP) Prototype    <br> Tested on Osteotomized Canine Femurs</b></p></font>      <p>Leonel Cardona R.<a name="no_1"></a><a href="#no1"><sup>1</sup></a> / Mariana Brousse<a name="no_2"></a><a href="#no2"><sup>2</sup></a> / Marcelo Mieres<a name="no_3"></a><a href="#no3"><sup>3</sup></a> / Sergio Arias<a name="no_4"></a><a href="#no4"><sup>4</sup></a> / &Eacute;dgar Guti&eacute;rrez<a name="no_5"></a><a href="#no5"><sup>5</sup></a></p>      ]]></body>
<body><![CDATA[<p><a name="no1"></a><a href="#no_1"><sup>1</sup></a> M&eacute;dico Veterinario, de Universidad de La Salle, EAH (Escuela Administraci&oacute;n de Negocios), MSc, de la Universidad Austral de Chile (Valdivia, Chile), investigador centro de investigaciones CISAHE, Unidad de Cirug&iacute;a de peque&ntilde;os animales (Bogot&aacute;, Colombia). <a href="mailto:lecardona@unisalle.edu.co">lecardona@unisalle.edu.co</a></p>      <p><a name="no2"></a><a href="#no_2"><sup>2</sup></a> M&eacute;dico Veterinario, de la Universidad Austral de Chile. Instituto de Ciencias Cl&iacute;nicas Veterinarias (Valdivia, Chile). <a href="mailto:mariana2080@hotmail.com">mariana2080@hotmail.com</a></p>      <p><a name="no3"></a><a href="#no_3"><sup>3</sup></a> M&eacute;dico Veterinario. MSc. de la Universidad Austral de Chile. Instituto de Ciencias Cl&iacute;nicas Veterinarias. Docente de planta de la Universidad Austral de Chile. Instituto de Ciencias Cl&iacute;nicas Veterinarias (Valdivia, Chile) <a href="mailto:mmieres@uach.cl">mmieres@uach.cl</a></p>      <p><a name="no4"></a><a href="#no_4"><sup>4</sup></a> M&eacute;dico Veterinario, de la Universidad de La Salle, internado en cirug&iacute;a de peque&ntilde;os animales de la UBA. MSc. y PhD en medicina y cirug&iacute;a de peque&ntilde;os animales de la Universidad Federal de Minas Gerais UFMG (Brasil). Investigador centro de investigaciones CISAHE, Unidad de Cirug&iacute;a de peque&ntilde;os animales (Bogot&aacute;, Colombia). <a href="mailto:searias@unisalle.edu.co">searias@unisalle.edu.co</a></p>      <p><a name="no5"></a><a href="#no_5"><sup>5</sup></a> M&eacute;dico Veterinario, de la Universidad de La Salle, MSc en Educaci&oacute;n y MSc (c) en Medicina Interna y cirug&iacute;a, de la Universidad de La Salle, investigador del centro de investigaciones CISAHE, Unidad de Cirug&iacute;a de peque&ntilde;os animales (Bogot&aacute;, Colombia). <a href="mailto:edgutierrez@unisalle.edu.co">edgutierrez@unisalle.edu.co</a></p>      <p><b>Recibido:</b> 3 de septiembre del 2010. <b>Aceptado:</b> 4 de marzo del 2011</p>  <hr>  <font size="3">     <br>    <p><b>Resumen</b></p></font>      <p align="justify">Las fracturas de huesos largos encontradas m&aacute;s frecuentemente en animales peque&ntilde;os son las del f&eacute;mur. Por su posici&oacute;n anat&oacute;mica, son dif&iacute;ciles de inmobilizar, entonces, la utilizaci&oacute;n de fijaciones internas es de gran utilidad. Las placas de compresi&oacute;n din&aacute;mica (PCD) proveen gran estabilidad, son durables y al producir compresi&oacute;n interfragmentaria, minimizan el movimiento fragmentario y promueven la cicatrizaci&oacute;n primaria del hueso. Sus ventajas est&aacute;n asociadas a la reconstrucci&oacute;n anat&oacute;mica, movilidad temprana y capacidad de carga del miembro. El polimetilmetacrilato (PMMA) es una resina acr&iacute;lica utilizada en pr&oacute;tesis dentales. Pero, estudios muestran otros usos, tratamientos de tumores &oacute;seos, pr&oacute;tesis en deformaciones craneales, vertebroplastias percut&aacute;neas y pr&oacute;tesis testiculares en animales, entre otros. El objetivo de este estudio fue fabricar PCD-PMMA y comprobar su resistencia a las distintas fuerzas que est&aacute;n presentes en una fractura. Se fabricaron 48 PCD de 3,5 mil&iacute;metros de cuatro orificios a partir de un molde de alginato. Se obtuvieron seis f&eacute;mures de cad&aacute;veres caninos de 10 a 20 kg de peso, a los cuales se les realiz&oacute; una osteotom&iacute;a que simulaba una fractura oblicua. Posteriormente, se posicionaron las placas en los huesos osteotomizados para someterlas a las distintas fuerzas que participan en una fractura. Las PCD-PMMA resistieron 2,83 newton/metro a la fuerza de torsi&oacute;n y 0,21 kilonewton a las fuerzas de compresi&oacute;n y flexi&oacute;n. La resistencia de la PCD-PMMA obtenida fue en promedio de 20 kg, a cada una de las fuerzas. Se pudo concluir que es posible fabricar una PCD-PMMA de 3,5 mm de cuatro orificios, cuya resistencia es de 20 kg de peso a las tres fuerzas aplicadas. Entonces, pueden ser utilizadas para la estabilizaci&oacute;n de fracturas de huesos largos que sean sometidos a una presi&oacute;n inferior a 20 kg de fuerza.</p>      <p align="justify"><b>Palabras clave: </b>placa compresi&oacute;n din&aacute;mica, polimetilmetacrilato, fractura.</p>  <hr>  <font size="3">     ]]></body>
<body><![CDATA[<br>    <p><b>Abstract</b></p></font>      <p align="justify">Femur fractures are the most frequent long bone fractures in small animals. Due to the femur's anatomical position, it is difficult to immobilize, and therefore internal fixations are very useful. Dynamic compression plates (DCP) provide high stability, are durable, minimize fragment movement and promote primary healing of the bone. Advantages of this treatment include anatomical reconstruction, early mobility and carrying capacity of the affected limb. Polymethylmethacrylate (PMMA) is an acrylic resin that has proved very useful in bone tumor treatment, cranial deformation prosthesis, percutaneous vertebroplasty and testicular prosthesis in animals. The purpose of this study was to manufacture DCP-PMMA and test its resistance to the different forces present in a fracture. Forty-eight (48) 3.5MM x 4-hole DCP were made from an alginate mold. Six (6) femurs were obtained from canine cadavers weighing from 10 to 20 kg, which underwent osteotomy simulating an oblique fracture. The plates were subsequently positioned in the osteotomized bones to submit them to the various forces involved in a fracture. The DCP-PMMA resisted a torque force of 2.83 newton/metres and a compression and flexion force of 0.21 kilonewton. The obtained resistance of the DCP-PMMA was an average of 20 kg per force. The results of this study show that it is possible to make a DCP-PMMA 3.5 mm x 4-hole, the resistance of which is of 20 kg against the three applied forces, and that it can be used to stabilize long bone fractures subjected to a pressure of less than 20 kg.</p>      <p align="justify"><b>Key words: </b>dynamic compression plate, polymethylmethacrylate, fracture.</p>  <hr>  <font size="3">     <br>    <p><b>Introducci&oacute;n</b></p></font>      <p align="justify">Las fracturas del f&eacute;mur son las fracturas de hueso largo encontradas m&aacute;s frecuentemente en animales peque&ntilde;os, por lo general, son relacionadas con un episodio traum&aacute;tico que implica un veh&iacute;culo motorizado. Debido a su posici&oacute;n anat&oacute;mica, las fracturas femorales no son f&aacute;cilmente inmobilizables, por esta raz&oacute;n, la fijaci&oacute;n interna, por lo general, es la indicada. Como la reducci&oacute;n anat&oacute;mica es el objetivo en la reconstrucci&oacute;n de fractura, el contorno de la placa debe ser exacta, sobre todo cuando la placa es colocada sobre el troc&aacute;nter mayor (Brinker et &aacute;l., 1984).</p>      <p align="justify">El entendimiento de los problemas curativos, con base en el conocimiento de la biomec&aacute;nica &oacute;sea, ha hecho evolucionar el tratamiento de las fracturas desde el simple entablillado hasta las t&eacute;cnicas actuales de osteos&iacute;ntesis (Rojas de la Rosa et &aacute;l., 2006). El objetivo primario del tratamiento de las fracturas es restaurar la funci&oacute;n total de la extremidad afectada (Slatter, 1989); se requiere una completa compresi&oacute;n de las fuerzas de la fractura para poder contrarrestar correctamente estas fuerzas con placas y tornillos (Slatter, 1989).</p>      <p align="justify">Durante la d&eacute;cada pasada, ha habido un considerable inter&eacute;s en el uso de las placas de compresi&oacute;n; aunque hay un papel definido para esta clase de placas en la ortopedia veterinaria, no es accesible a todos los propietarios, ya que su costo es muy elevado (Denny, 1982), sin embargo, las placas de compresi&oacute;n din&aacute;mica (PCD) proveen mayor estabilidad. Las placas usadas en medicina veterinaria est&aacute;n disponibles en variados tama&ntilde;os, formas y dise&ntilde;os; la placa elegida depende de numerosos factores, incluyendo la fuerza mec&aacute;nica necesitada por el tama&ntilde;o del hueso y el nivel de actividad del animal, el tama&ntilde;o y tipo del segmento fracturado y el m&eacute;todo de aplicaci&oacute;n.</p>      <p align="justify">Cuando se obtiene la reducci&oacute;n anat&oacute;mica, las placas realizan una mayor resistencia a las fuerzas y extienden su durabilidad, compartiendo el peso con el hueso (Stiffler, 2004). Las placas est&aacute;ndar vienen en distintos largos y son nombradas por el tama&ntilde;o de los tornillos usados; las placas m&aacute;s usadas en cirug&iacute;a de peque&ntilde;os animales son de 1,5; 2,0; 2,7 y 3,5 mm. Ha ido emergiendo el dise&ntilde;o de nuevas placas para ir mejor&aacute;ndolas cada d&iacute;a m&aacute;s (Stiffler, 2004). Las PCD dise&ntilde;adas para la compresi&oacute;n axial son unos de los tipos m&aacute;s utilizados; se reconocen por sus agujeros ovalados para la inserci&oacute;n exc&eacute;ntrica de los tornillos, cuyas paredes son biseladas hacia el piso e inclinadas hacia medial. La zona m&aacute;s d&eacute;bil de estas placas est&aacute; alrededor de los agujeros, ya que es la &uacute;nica zona que se puede doblar (Garc&iacute;a y Ortega, 2005).</p>      ]]></body>
<body><![CDATA[<p align="justify">Cuando se posiciona la placa de manera que est&aacute; bajo tensi&oacute;n y los fragmentos de la fractura est&aacute;n bajo compresi&oacute;n, se denomina placa de compresi&oacute;n o alternativamente, placa de banda de tensi&oacute;n. Los huesos largos (por ejemplo: f&eacute;mur) est&aacute;n sujetos a cargas exc&eacute;ntricas y se pueden comparar con una columna doblada. El lado lateral est&aacute; sujeto a fuerzas de distracci&oacute;n o tensi&oacute;n y el medial, a fuerzas de impacto o compresi&oacute;n (Piermattei y Flo, 1999). Cuando una placa se posiciona en la cara lateral del f&eacute;mur, contrarresta todas las fuerzas de tensi&oacute;n y crea fuerzas de compresi&oacute;n a lo largo de la l&iacute;nea de fractura; por ello, ofrece una fijaci&oacute;n interna r&iacute;gida (Piermattei y Flo, 1999).</p>      <p align="justify">El polimetilmetacrilato (PMMA) es una resina acr&iacute;lica utilizada en moldes para fabricar pr&oacute;tesis dentales y puede cumplir la funci&oacute;n de barra estabilizadora-conectora en la reducci&oacute;n de fracturas, lo que permite la colocaci&oacute;n de clavos en planos m&uacute;ltiples (Cavero y Fern&aacute;ndez, 2005). El PMMA es un termopl&aacute;stico duro, r&iacute;gido y transparente, que tiene buena resistencia a las condiciones atmosf&eacute;ricas y es m&aacute;s resistente al impacto que el vidrio. Este material es m&aacute;s conocido por sus marcas comerciales Plexiglas o Lucite y es el material m&aacute;s importante dentro del grupo de los termopl&aacute;sticos denominados acr&iacute;licos (Smith, 2000). Este pol&iacute;mero es de composici&oacute;n s&oacute;lida (polvo) y, por su parte, el mon&oacute;mero MMC es de composici&oacute;n l&iacute;quida; ambos dan origen al acr&iacute;lico, al que se le puede dar distintos usos (Moreno et &aacute;l., 2003). Tanto el polvo como el l&iacute;quido son qu&iacute;micamente la misma sustancia (metilmetacrilato) y solamente existen diferencias en cuanto a la forma de combinaci&oacute;n de las mol&eacute;culas. Cuando las mol&eacute;culas del metilmetacrilato se presentan en su forma m&aacute;s simple o primitiva, no ofreciendo una combinaci&oacute;n definida, se le denomina mon&oacute;mero y su estado f&iacute;sico es l&iacute;quido. El polvo es metilmetacrilato con cierto grado de polimerizaci&oacute;n (PMMA) y se le identifica como pol&iacute;mero. En el pol&iacute;mero se encuentran mol&eacute;culas mayores, como consecuencia de peque&ntilde;os fen&oacute;menos de polimerizaci&oacute;n activados generalmente por la acci&oacute;n de factores externos (calor, luz, rayos ultravioletas, etc.) que act&uacute;an en presencia de ox&iacute;geno (Jim&eacute;nez, 1962).</p>      <p align="justify">Existen estudios que demuestran que el PMMA puede ser utilizado en organismos animales, sin producir efectos perjudiciales para el organismo; en estos estudios, se nombra la utilizaci&oacute;n en tumores &oacute;seos, esto se encuentra descrito por Moreno et &aacute;l. (2003), en el que se&ntilde;alan que las caracter&iacute;sticas beneficiosas del PMMA se basan, principalmente, en el efecto t&eacute;rmico y qu&iacute;mico producido por la reacci&oacute;n de polimerizaci&oacute;n, lo que eleva la temperatura en el seno de la masa de PMMA hasta 133&deg;C, cifra que sobrepasa la necesaria para la coagulaci&oacute;n de las prote&iacute;nas que es de 56&deg;C, por lo que conduce a muerte celular. Adem&aacute;s, el mon&oacute;mero presenta una gran afinidad por las grasas, lo que provoca una disoluci&oacute;n de las lipoprote&iacute;nas de las membranas celulares y tambi&eacute;n conduce a la muerte de las c&eacute;lulas neopl&aacute;sicas remanentes.</p>      <p align="justify">De igual manera, Kubo et &aacute;l. (1998) crearon un bastidor del hueso temporal de PMMA para los tumores que afectan este hueso del cr&aacute;neo. Otro estudio realizado por Cruz y Arce (2000) tambi&eacute;n demuestra que las deformidades craneales causadas por traumatismo, infecciones, neoplasias y defectos cong&eacute;nitos pueden ser tratadas por medio de pr&oacute;tesis; para esto, se cuenta con materiales alopl&aacute;sticos como el PMMA. En el estudio realizado por Vassallo y Caruso (1987), quienes reemplazaron grandes resecciones de pared tor&aacute;cica por una pr&oacute;tesis de marlex y PMMA. Igualmente, Hern&aacute;ndez et &aacute;l. (2004) describieron la aplicaci&oacute;n percut&aacute;nea de un pol&iacute;mero acr&iacute;lico (PMMA) a defectos del cuerpo vertebral asociados con dolor en fracturas por osteoporosis y lesiones tumorales en humanos con resultado satisfactorio, en relaci&oacute;n con el control del dolor hasta en 90% de los casos.</p>      <p align="justify">L&oacute;pez y Gonz&aacute;lez (2004) utilizaron el cemento acr&iacute;lico PMMA para la realizaci&oacute;n de una vertebroplast&iacute;a percut&aacute;nea para proporcionar alivio del dolor y prevenir el colapso vertebral y la seudoartrosis en pacientes con fracturas vertebrales osteopor&oacute;sicas al incrementar la estabilidad mec&aacute;nica. Se realizaron en perros, conejos y ratas; pr&oacute;tesis testiculares de PMMA autopolimerizable y PMMA termocurable, se implantaron en las bolsas escrotales despu&eacute;s de la orquiectom&iacute;a inguinal. Los resultados fueron buena tolerancia, biocompatibilidad y no toxicidad, y no se observaron reacciones titulares locales ni sist&eacute;micas (Manzanilla et &aacute;l., 1992). B&oacute;rzei et &aacute;l. (2006) realizaron un estudio comparativo entre c&aacute;psulas y granos de PMMA que conten&iacute;an antibi&oacute;ticos, en el cual se determin&oacute; que este tuvo una salida m&aacute;s duradera y de mayor concentraci&oacute;n en las c&aacute;psulas de PMMA que de los granos. Esto demuestra que la asociaci&oacute;n de PMMA y antibi&oacute;ticos ya se ha estudiado con resultados positivos.</p>  <font size="3">     <br>    <p><b>Materiales y m&eacute;todos</b></p></font>      <p align="justify">Este estudio se realiz&oacute; en las dependencias del Hospital Veterinario de la Universidad Austral de Chile, con la colaboraci&oacute;n del Laboratorio de Ensayo de Materiales de Construcci&oacute;n del Instituto de Obras Civiles de la Facultad de Ciencias de la Ingenier&iacute;a del Campus Miraflores de la Universidad Austral de Chile, entre los meses agosto y noviembre.</p>      <p align="justify">Se utilizaron seis huesos femorales; tres derechos y tres izquierdos de caninos adultos (2 a 7 a&ntilde;os) entre 10 a 20 kg de peso, sin distinci&oacute;n de raza y sexo. Para la evaluaci&oacute;n de fuerzas se utilizaron: equipo de flexi&oacute;n y compresi&oacute;n: se utiliz&oacute; una prensa con anillo de carga N&deg; serie K55 (c&oacute;d. EQ-19), con una capacidad de 50 kN y que ejerce la fuerza de manera vertical. Un dial de anillo marca Ele con divisi&oacute;n 0,0001 pulgadas. Tambi&eacute;n se utiliz&oacute; un aplomo externo de 12 cm, uno interno de 5 cm, la distancia entre los apoyos internos y externos fue de 2,24 cm. Equipo de torsi&oacute;n: se utiliz&oacute; una m&aacute;quina de torsi&oacute;n marca Tecquipment, tipo SM1, con platos 13/B16 Rohm William de 1/32 1/2 pulgadas.</p>  <font size="3">     <br>    ]]></body>
<body><![CDATA[<p><b>M&eacute;todo de obtenci&oacute;n del f&eacute;mur</b></p></font>      <p align="justify">Se obtuvieron los huesos femorales de cad&aacute;veres de perros dom&eacute;sticos <i>(Canis lupusfamiliaris) </i>con un peso entre 10 y 20 kg, facilitados por el Hospital Veterinario de la Universidad Austral de Chile, a los cuales se les practic&oacute; la eutanasia por razones ajenas al estudio. La obtenci&oacute;n de los f&eacute;mures se realiz&oacute; inmediatamente despu&eacute;s de la eutanasia de los animales, para posteriormente ser limpiados de tejidos. Luego, fueron tratados con agua oxigenada y cloro para retirar el exceso de grasa propio del hueso y una vez limpios se sometieron a las pruebas biomec&aacute;nicas del estudio, en fresco.</p>  <font size="3">     <br>    <p><b>M&eacute;todo de fabricaci&oacute;n del molde de alginato</b></p></font>      <p align="justify">Se fabric&oacute; un molde de la PCD, que se obtuvo a partir de una mezcla de alginato en polvo con agua, homogeniz&aacute;ndola hasta observar un cambio de color de celeste a blanquecino, lo cual indicaba que la mezcla est&aacute; lista para ser utilizada, siendo depositada en un recipiente pl&aacute;stico. Seguido a esto se coloc&oacute; sobre la mezcla la PCD de acero quir&uacute;rgico y se tom&oacute; el molde, se dej&oacute; hasta que tom&oacute; una textura semis&oacute;lida durante 10 minutos despu&eacute;s y, posteriormente, se extrajo la placa, quedando as&iacute; el molde negativo.</p>  <font size="3">     <br>    <p><b>M&eacute;todo de fabricaci&oacute;n de la placa de compresi&oacute;n din&aacute;mica de polimetilmetacrilato</b></p></font>      <p align="justify">Se fabricaron 48 PCD; para esto se realiz&oacute; la mezcla de PMMA (20 g de acr&iacute;lico y 5 ml del mon&oacute;mero); una vez que estuvo homogenizada se verti&oacute; la soluci&oacute;n en el molde de alginato. Se dej&oacute; secar por 30 minutos a temperatura ambiente. Luego de obtener la PCD-PMMA se puli&oacute; con un motor de mano hasta que la superficie qued&oacute; no porosa.</p>  <font size="3">     <br>    <p><b>M&eacute;todo de fractura del f&eacute;mur</b></p></font>      ]]></body>
<body><![CDATA[<p align="justify">Se realiz&oacute; una osteotom&iacute;a oblicua de 20&deg; en la di&aacute;fisis media, mediante una cierra oscilante (Aesculap-Alemania), en todos los f&eacute;mures utilizados.</p>  <font size="3">     <br>    <p><b>M&eacute;todo de fijaci&oacute;n de la placa de compresi&oacute;n din&aacute;mica</b></p></font>      <p align="justify">Seguido a esto, se ubic&oacute; la PCD-PMMA con una pinza de hueso Holding. Luego, el f&eacute;mur se perfor&oacute; con una broca de 3,2 mm, puesta en un taladro el&eacute;ctrico de baja revoluci&oacute;n, a continuaci&oacute;n, se utiliz&oacute; un medidor de profundidad ortop&eacute;dico para elegir los tornillos adecuados, luego con un macho de rosca de un di&aacute;metro de 3,5 mm, se hizo el haz de hilo. Se ubic&oacute; la zona medial de la placa sobre la osteotom&iacute;a femoral y se posicionaron los tornillos corticales con un atornillador de Allen en los cuatro puntos desde los centrales hacia afuera.</p>  <font size="3">     <br>    <p><b>M&eacute;todo de prueba de la placa de compresi&oacute;n din&aacute;mica</b></p></font>      <p align="justify">Para la adaptaci&oacute;n del f&eacute;mur a las m&aacute;quinas se seccionaron la ep&iacute;fisis proximal (cabeza femoral, troc&aacute;nter mayor y troc&aacute;nter menor) y la ep&iacute;fisis distal (c&oacute;ndilo medial y lateral). Seguido a esto, se crearon dos bases de PMMA para ajustar los extremos del f&eacute;mur a la m&aacute;quina de torsi&oacute;n. Luego, para probar la resistencia de la PCD-PMMA a la prueba de flexi&oacute;n, se posicion&oacute; el f&eacute;mur en la prensa horizontalmente. Se procedi&oacute; a girar en forma r&aacute;pida la manivela de la prensa hasta que la PCD-PMMA se quebr&oacute;, estos datos fueron medidos en kilonewton (kN). Para la prueba de compresi&oacute;n, se posicion&oacute; el f&eacute;mur en forma vertical, previamente los dos extremos del f&eacute;mur fueron pulidos para que las superficies estuvieran alineadas en la prensa; estos datos tambi&eacute;n fueron medidos en kN. La prueba de torsi&oacute;n se realiz&oacute; encajando el f&eacute;mur a los platos de la m&aacute;quina, para poder adaptarlos se debi&oacute; fabricar una base de PMMA. La unidad de medida utilizada en esta prueba fue newton metro (Nm).</p>  <font size="3">     <br>    <p><b>Obtenci&oacute;n de datos</b></p></font>      <p align="justify">Los datos obtenidos en la prensa que se utiliz&oacute; para las fuerzas de compresi&oacute;n y flexi&oacute;n debieron ser transformados para obtener la fuerza en kilonewton; para esto, se utiliz&oacute; la siguiente f&oacute;rmula: Y= aX + b</p>      ]]></body>
<body><![CDATA[<p align="justify">Donde:</p>      <p align="justify">a = 0,0582; b = 0,1472 y X = n&uacute;mero que marc&oacute; la prensa.</p>      <p align="justify">Luego para transformar los kN en kg se utiliz&oacute; la siguiente f&oacute;rmula:</p>      <p align="justify">1 kN = 100 kg</p>      <p align="justify">La m&aacute;quina de torsi&oacute;n proporcion&oacute; los datos en newton/metro (Nm), por tanto, se utilizaron estos datos para la discusi&oacute;n, pero para transformar los datos a kilogramos, se utiliz&oacute; la siguiente f&oacute;rmula: M = fx d</p>      <p align="justify">Donde:</p>      <p align="justify">M: newton/metro;</p>      <p align="justify">f: fuerza en N y d: distancia en metros entre el marcador y el inicio de la m&aacute;quina</p>  <font size="3">     <br>    <p><b>An&aacute;lisis de datos</b></p></font>      ]]></body>
<body><![CDATA[<p align="justify">Para el an&aacute;lisis de los datos, se utiliz&oacute; una descripci&oacute;n de la PCD-PMMA, de su resistencia y la din&aacute;mica de quiebre de esta en porcentajes. Los resultados obtenidos fueron expresados como medias aritm&eacute;ticas y sus errores est&aacute;ndares de la media, a partir de la utilizaci&oacute;n de estad&iacute;stica descriptiva e inferencial.</p>  <font size="3">     <br>    <p><b>Resultados</b></p></font>  <font size="3">     <p><b>Placa de compresi&oacute;n din&aacute;mica de polimetilmetacrilato</b></p></font>      <p align="justify">Se cre&oacute; una PCD-PMMA de 3,5 mm y cuatro orificios, con caracter&iacute;sticas similares a la PCD de acero quir&uacute;rgico LN 344; sin embargo, el grosor de la nueva placa era mayor en aproximadamente 2 mm (<a href="#f01">figura 1</a>). Se logr&oacute; fabricar una placa lisa y no porosa. El peso obtenido fue en promedio de 1,9 g, lo que es muy inferior al peso de las PCD de acero quir&uacute;rgico (9,3 g).</p>      <p align="center"><a name="f01"></a><img src="img/revistas/rmv/n21/n21a02f01.jpg"></p>  <font size="3">     <br>    <p><b>Resistencia de la placa de compresi&oacute;n din&aacute;mica</b></p></font>      <p align="justify">En la <a href="#t01">tabla 1</a> se muestra el grado de resistencia que soport&oacute; la PCD-PMMA fue similar en las fuerzas de compresi&oacute;n y flexi&oacute;n. Por otro lado, la fuerza de torsi&oacute;n que se registr&oacute; en Nm fue de un valor mayor. En cuanto a la resistencia en kilo-fuerza, fue muy similar para las tres fuerzas. Las PCD en PMMA fueron evaluadas como m&eacute;todo de fijaci&oacute;n interna <i>in vitro, </i>lo que fue registrado, valorando la resistencia en kilogramos de la PCD-PMMA a las distintas fuerzas. Para esto, se utilizaron dos f&oacute;rmulas, una para transformar kN en kg y otra para transformar los Nm en kg, seg&uacute;n Beer et &aacute;l. (2004) y anteriormente descritas.</p>      <p align="center"><a name="t01"></a><img src="img/revistas/rmv/n21/n21a02t01.jpg"></p>      ]]></body>
<body><![CDATA[<p align="justify">En la <a href="#t02">tabla 2</a> se observa que PCD-PMMC a las tres fuerzas demostraron que dependiendo de la fuerza utilizada estas se quebraron en diferentes n&uacute;meros de partes.</p>      <p align="center"><a name="t02"></a><img src="img/revistas/rmv/n21/n21a02t02.jpg"></p>      <p align="justify">El punto m&aacute;s d&eacute;bil de la PCD-PMMA, es decir, donde se produjo la totalidad de las rupturas al someterlas a las distintas fuerzas, fue en el borde de los orificios centrales 2 y 3 (<a href="#f02">figura 2</a>).</p>      <p align="center"><a name="f02"></a><img src="img/revistas/rmv/n21/n21a02f02.jpg"></p>  <font size="3">     <br>    <p><b>Discusi&oacute;n</b></p></font>      <p align="justify">En este estudio se utilizaron PCD, ya que proveen mayor estabilidad en procesos fracturarios al minimizar el movimiento fragmentario y al promover la cicatrizaci&oacute;n primaria del hueso (Stiffler, 2004). La funci&oacute;n de un dispositivo para fijaci&oacute;n interna es inmovilizar y hacer m&aacute;s r&iacute;gidos los fragmentos fracturarios, desde el inicio de la curaci&oacute;n de la fractura, lo que garantiza una osteos&iacute;ntesis estable y duradera. Las ventajas de este tratamiento est&aacute;n asociadas a la reconstrucci&oacute;n anat&oacute;mica, la movilidad temprana y la capacidad de carga del miembro afectado (Tovar et &aacute;l., 2002).</p>      <p align="justify">Asimismo, Dueland et &aacute;l., en 1996, reportaron que, actualmente, este tipo de implante es usado en la pr&aacute;ctica veterinaria con sus respectivas ventajas, que se encuentran reportadas en la literatura, en relaci&oacute;n con la influencia biol&oacute;gica y mec&aacute;nica en la curaci&oacute;n de huesos. Fettig et &aacute;l. (2002) comprobaron el buen resultado de las fijaciones con PCD de 2,0/2,7 mm o 2,7/3,5 mm en un estudio <i>in vivo </i>realizado en caninos con enfermedades articulares, que se mejoraron en un promedio en 1 a&ntilde;o 4 meses.</p>      <p align="justify">Beaupre et &aacute;l. (1988) probaron las PCD a las fuerzas de flexi&oacute;n y torsi&oacute;n, ya que estas son las cargas de aproximaci&oacute;n experimentadas cl&iacute;nicamente. Se utilizaron PCD-PMMA de 3,5 mm y cuatro orificios por su uso cotidiano en animales peque&ntilde;os; aunque no com&uacute;nmente en fracturas femorales, se pueden valorar sus caracter&iacute;sticas de resistencia a las fuerzas de la fractura. Tominaga et &aacute;l. (2006) utilizaron las PCD de cuatro orificios en osteos&iacute;ntesis del proceso subcondilar mandibular humano, en este estudio se utiliz&oacute; una m&aacute;quina hidr&aacute;ulica en la que la carga del vector simul&oacute; fuerzas fisiol&oacute;gicas sobre el c&oacute;ndilo hasta el quiebre de la placa. En este estudio, midieron la curva de desplazamiento de carga, la carga m&aacute;xima para el quiebre y la rigidez. Sin embargo, no se encontr&oacute; ning&uacute;n estudio hasta la fecha que eval&uacute;e una PCD de PMMA en un modelo de fractura de f&eacute;mur canino.</p>      <p align="justify">Asimismo, se utiliz&oacute; una PCD-PMMA para las pruebas biomec&aacute;nicas, en las que se ha tratado de evaluar la eficacia de este tipo de PCD en fracturas creadas en huesos femorales de perros, ya que se han realizado diversos estudios en los que se ha evaluado la utilidad del PMMA impregnado de antibi&oacute;tico, comparado con sustituto &oacute;seo bioabsorbible, e impregnado antibi&oacute;ticos despu&eacute;s de desbridamiento quir&uacute;rgico en pacientes con osteomielitis cr&oacute;nica no hemat&oacute;geno o infectados en humanos (McKee et &aacute;l., 2010). Como se ha examinado en el ganado ovino, el efecto de la interposici&oacute;n de una capa de cemento de hidroxiapatita en la periferia de una toma de polietileno antes de la colocaci&oacute;n utilizando PMMA en la superficie del acet&aacute;bulo (Timper-ley et &aacute;l., 2010), deja una ventana abierta para la evaluaci&oacute;n futura de este m&eacute;todo de fijaci&oacute;n con interfases de biomateriales que desarrollen facilidad de osteointegraci&oacute;n. Tominaga et &aacute;l. (2006) describieron la utilizaci&oacute;n de una PCD fabricada con base en un pol&iacute;mero denominado polilactato, que fue probado en fracturas subcondilares, al simular las fuerzas fisiol&oacute;gicas producidas por los c&oacute;ndilos durante la masticaci&oacute;n.</p>      ]]></body>
<body><![CDATA[<p align="justify">La preparaci&oacute;n de la mezcla de PMMA mostr&oacute; una buena solidez posterior a la reacci&oacute;n de polimerizaci&oacute;n con el protocolo de preparaci&oacute;n utilizado, el cual es coincidente con la realizada por Cavero y Fern&aacute;ndez (2005), quienes realizaron una mezcla de PMMA polvo y mon&oacute;mero l&iacute;quido en un envase de pl&aacute;stico con tres partes del polvo por una l&iacute;quida, para la fabricaci&oacute;n de una barra estabilizadora-conectora utilizada para la reducci&oacute;n de fracturas con el m&eacute;todo de fijaci&oacute;n de Kirschner-Ehmer en caninos.</p>      <p align="justify">En este estudio, se utiliz&oacute; un f&eacute;mur para las pruebas biomec&aacute;nicas, coincidiendo con lo se&ntilde;alado por Bernarde et &aacute;l. (2001), quienes utilizaron este modelo para comparar las propiedades estructurales y el movimiento interfragmentario en f&eacute;mures osteotomizados caninos estabilizados con una PCD de 8 mm y 10 orificios. Radcliffe (2001) compar&oacute; las propiedades biomec&aacute;nicas de f&eacute;mures de caballo intactos inmaduros con tres m&eacute;todos de estabilizaci&oacute;n en f&eacute;mures osteotomizados. Existen estudios realizados en f&eacute;mures de cad&aacute;veres humanos, como lo reportado por Tejwani et &aacute;l. (2005), quienes realizaron un estudio biomec&aacute;nico, en el que evaluaron la importancia de los tornillos de bloqueo distal en el enclavado retr&oacute;grado de las fracturas osteopor&oacute;ticas de f&eacute;mur distal. A su vez, Sears et &aacute;l. (2004) realizaron un estudio con f&eacute;mures osteotomizados para probar clavos supracondilares retr&oacute;grados largos y cortos. Garc&iacute;a et &aacute;l. (2000) presentaron un estudio biomec&aacute;nico comparativo entre el clavo endomedular retr&oacute;grado y el tornillo cond&iacute;leo din&aacute;mico tambi&eacute;n en f&eacute;mures humanos.</p>      <p align="justify">Inicialmente, se utiliz&oacute; un bistur&iacute; para la remoci&oacute;n de piel, m&uacute;sculos, vasos sangu&iacute;neos, nervios, y luego ba&ntilde;os con agua oxigenada y cloro, lo que difiere con lo reportado por Bernarde et &aacute;l. (2001), quienes utilizaron una t&eacute;cnica de congelamiento, con lo que pudieron extraer f&aacute;cilmente el tejido blando sobrante, as&iacute; como con lo reportado por Jain et &aacute;l. (1998), quienes aplicaron al hueso un ba&ntilde;o de agua a 37&deg;C, simulando la temperatura corporal del canino. Por otro lado, Sod et &aacute;l. (2006) utilizaron toallas empapadas de una soluci&oacute;n de NaCl al 0,9% para envolver los huesos y someterlos a una temperatura de -21&deg;C, los cuales fueron descongelados a temperatura ambiente para luego retirar los tejidos blandos. El modelo de fractura de f&eacute;mur canino se eligi&oacute; basado en el hecho de que son fracturas comunes en perros y su reparaci&oacute;n representa un reto para el m&eacute;dico veterinario, actualmente. Se eligi&oacute; osteotom&iacute;a del esp&eacute;cimen &oacute;seo en busca de la simulaci&oacute;n de una fractura t&iacute;pica sin minuta, sin distracci&oacute;n, manteniendo el tama&ntilde;o fisiol&oacute;gico del hueso, como lo indica Bernarde et &aacute;l., en el 2001. Lo que difiere con lo reportado por Sears et &aacute;l., (2004) quienes utilizaron para su estudio biomec&aacute;nico osteotom&iacute;as femorales transversales.</p>      <p align="justify">Se utilizaron tres de las cuatro fuerzas descritas por Roush y McLaughlin, en 1993, que act&uacute;an para que se produzca una fractura, estas fuerzas fueron: de torsi&oacute;n, flexi&oacute;n y compresi&oacute;n axial. Sod et &aacute;l., en el 2006, utilizaron las fuerzas de flexi&oacute;n y torsi&oacute;n en un estudio para comparar PCD con Placas de Compresi&oacute;n Din&aacute;mica de bajo contacto (LC- DCP) en huesos metacarpales equinos. Por otro lado, &Aacute;guila et &aacute;l. (2005) solo utilizaron la fuerza de compresi&oacute;n en un estudio que realizaron para comparar la resistencia entre la PCD en huesos caninos, al igual que Bernarde et &aacute;l. (2001), quienes utilizaron la misma fuerza para comparar una PCD con un clavo intramedular en huesos caninos.</p>  <font size="3">     <br>    <p><b>Equipos biomec&aacute;nicos</b></p></font>      <p align="justify">El equipo utilizado para el estudio biomec&aacute;nico de fuerza de torsi&oacute;n es similar al utilizado por Ahmad et &aacute;l. (2007) y Jain et &aacute;l. (1998), quienes realizaron estudios para probar la resistencia de PDC y LC-DCP. Para las fuerzas de flexi&oacute;n y compresi&oacute;n, se utiliz&oacute; una prensa manual, lo que difiere de lo reportado por Sod et &aacute;l. (2005), estudio en el que se utilizaron equipos fabricados especialmente por ellos para lograr la fuerza de compresi&oacute;n y un torque para la fuerza de flexi&oacute;n; en los dos equipos se pod&iacute;a seleccionar el tiempo en segundos y la fuerza en kN. El posicionamiento del f&eacute;mur en la m&aacute;quina de torsi&oacute;n es concordante con lo reportado por Jain et &aacute;l. (1998), quienes usaron PMMA para adaptar las bases del radio en la m&aacute;quina y as&iacute; poder probar la resistencia de placas de 3,5 mm de ocho orificios de distintos materiales (acero inoxidable, titanio, etc.) en radios caninos. Mientras que Sod et &aacute;l. (2006), utilizaron fibra de vidrio para este fin, por ser este un material duro y resistente. El posicionamiento del f&eacute;mur en la prensa, para la fuerza de flexi&oacute;n concuerda con la utilizada por Sod et &aacute;l., en el 2006, para la cual utilizaron dos soportes met&aacute;licos de distinto tama&ntilde;o 2 y 4 cm, ubicados, uno sobre y otro debajo del hueso respectivamente logrando as&iacute; que se generaran puntos espec&iacute;ficos donde deb&iacute;a actuar la fuerza.</p>      <p align="justify">La utilizaci&oacute;n de PCD en medicina veterinaria es reducida, debido al costo que esto significa para el propietario, por esto, la utilizaci&oacute;n de PCD-PM-MA permite reducir el valor de esta en forma significativa y abrir ventanas en la utilizaci&oacute;n de este tipo de fijaci&oacute;n interna, asociada a biomateriales de interfase, antibi&oacute;ticos en fracturas contaminas o con osteomielitis.</p>  <font size="3">     <br>    <p><b>Conclusiones</b></p></font>      ]]></body>
<body><![CDATA[<p align="justify">Fue posible fabricar una Placa de Compresi&oacute;n Din&aacute;mica de 3,5 mm de 4 orificios de polimetilmetacrilato. La resistencia de la placa de compresi&oacute;n din&aacute;mica de polimetilmetacrilato de 3,5 mm de 4 orificios, fue superior a los 20 kg de peso en las tres fuerzas aplicadas.</p>      <p align="justify">Las placas de compresi&oacute;n din&aacute;mica de 3,5 mm y 4 orificios de polimetilmetacrilato pueden ser utilizadas para la estabilizaci&oacute;n de fracturas de huesos largos que sean sometidos a una presi&oacute;n inferior a 20 kg de fuerza.</p>  <font size="3">     <br>    <p><b>Agradecimientos</b></p></font>      <p align="justify">Los autores agradecen al Hospital Veterinario del Instituto de Ciencias Cl&iacute;nicas de la Universidad Austral de Chile y al Laboratorio de Ensayo de Materiales de Construcci&oacute;n del Instituto de Obras Civiles de la Facultad de Ciencias de la Ingenier&iacute;a del Campus Miraflores de la Universidad Austral de Chile y al personal de estas dependencias que colabor&oacute; con el desarrollo de esta investigaci&oacute;n.</p>  <hr>  <font size="3">     <br>    <p><b>Referencias</b></p></font>      <!-- ref --><p align="justify">&Aacute;guila, A., Manos, J., Orlansky, A., Todhunter, R., Trotter, E. y Van der Muelen, M. (2005). In Vitro biomechanical comparison of limited contact dynamic compression plate and holding compression plate. <i>Vet Comp Orthop Traumatol, 4, </i>220-226.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0122-9354201100010000200001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Ahmad, M., Nanda, R., Green, A. y Hui, A. (2007). Biomecanical testing of the locking compression plate: when does the distance between bone and implant significanthy reduce construct stability. <i>Vet Comp Orthop Traumatol, </i>3, 358-364.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0122-9354201100010000200002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Beaupre, G., Carter, D., Dueland, R., Caler, W. y Spengler, D. (1988). A biomechanical assessment of plate fixation, with insufficient bony support. <i>J Orthop Res, 6, </i>721.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0122-9354201100010000200003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Beer, F., Johnston, E., y Staab, G. (2004). Sistema de unidades. En <i>Mec&aacute;nica vectorial para ingenieros. </i>Mc Graw Hill.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0122-9354201100010000200004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Bernarde, A., Diop, A., Laurel, N. y Viguier, E. (2001). An in vitro biomechanical study of bon plate and interlocking nail in a canine diaphyseal femoral model. <i>Vet Sur, 30, </i>397-408.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0122-9354201100010000200005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">B&ouml;rzei, L., Mintal, T., Horv&aacute;th, A. Ko&oacute;s, Z., Kocsis, B. y Ny&aacute;r&aacute;dy, J. (2006). Comparative study of antibiotic containing polymethylmetacrylate capsules and beads. Departments of Traumatology and hand Surgery and Microbiology, Faculty of Medicine. University of P&eacute;cs, P&eacute;cs, Hungary. <i>Chemotherapy, 52, </i>1-8.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0122-9354201100010000200006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Brinker, W., Hohn, R. y Prieur, W. (1984). Fracture of the femur. En <i>Manual of internal fixation in small animals </i>(118-133). Springer.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0122-9354201100010000200007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Cavero, F. y Fern&aacute;ndez, V. (2005). Utilizaci&oacute;n del acr&iacute;lico dental (metilmetacrilato) como barra estabilizadora-conectora para reducciones cerradas en fracturas de tibia/peron&eacute; o radio/c&uacute;bito en caninos. <i>Rev Inv Vet, 16, </i>17-23.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0122-9354201100010000200008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Cruz, M. y Arce, M. (2000). Implantes craneales. XVII Reuni&oacute;n Nacional M&eacute;dica del Instituto Nacional de Cancerolog&iacute;a. <i>Rev Inst Nac Canc, 46, </i>116-135.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0122-9354201100010000200009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Denny, H. (1982). Tratamiento de las fracturas. En <i>Fundamentos de cirug&iacute;a ortop&eacute;dica canina </i>(105-109). Madrid: Acribia.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0122-9354201100010000200010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Dueland, R., Berglund, L. y Vanderby, Jr. (1996). Structural properties of interlocking nails, canine femora, and femurinterlocking nail constructs. <i>Vet Surg, 25, </i>386-396.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0122-9354201100010000200011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Fettig, A., McCarthy, R. y Kowaleski, M. (2002). Intertarsal and tarsometatarsal arthrodesis using 2.0/ 2.7mm or 2.7/3.5-mm hybrid dynamic compression plates. <i>J A Anim Hosp Assoc, 38, </i>364-369.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0122-9354201100010000200012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Garc&iacute;a, C. y Ortega, D. (2005). Elementos de osteos&iacute;ntesis de uso habitual en fracturas del esqueleto apendicular: evaluaci&oacute;n radi&oacute;logica. <i>Rev Chil Radiol, 11, </i>58-70.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0122-9354201100010000200013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Garc&iacute;a, O., Morando, G., Mastropierro, J., M&eacute;ndez, J., DiGiacomo, M., Cocozzella, L., Maletti, P., Dapia, C.&nbsp;, Solis, H., Guerrero, C., Lupacchini, M., Hiriart, N., Garc&iacute;a, V. y Villamil, F. (2000). Fracturas supracond&iacute;leas de f&eacute;mur: estudio biomec&aacute;nico comparativo entre el clavo endomedular retr&oacute;grado y el tornillo cond&iacute;leo din&aacute;mico / Supracondylar femur fractures: a comparative biomechanical study between retrograde  endomedullary nail and dynamic condylar screw. <i>Rev Asoc Argent Orto Traumatol, </i>65, 48-53.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0122-9354201100010000200014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Hern&aacute;ndez, B., Bravo, P. y Camarillo, F. (2004). Vertebroplast&iacute;a transpedicular percut&aacute;nea con metilmetacrilato. Tratamiento del dolor por aplastamiento vertebral osteop&eacute;nico. <i>Acta Ortop Mex, 18, </i>82-85.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0122-9354201100010000200015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Hulse, D., Hyman, W. y Nori, M. (1997). Reduction in plate strain by addition of an intramedullary pin. <i>Vet Surg, 26, </i>451-459.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0122-9354201100010000200016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Jain, R., Podworny, N., Hearn, T., Robin, R. y Schemitsch, E. (1998). A biomecanical evaluation of different plates for fixation of canine radial osteotomies. <i>Journal of Trauma Injury and Critical Care, 44, </i>193-197.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0122-9354201100010000200017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Jim&eacute;nez, G. (1962). Incrustaciones de acr&iacute;lico: primer informe sobre 180 casos cl&iacute;nicos. <i>Rev Univ de Zulia, 17, </i>35-67.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0122-9354201100010000200018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Kubo, S., Fukushima, T., Yoshimine, T., Miki, H. y Hayakawa, T. (1998). Methylmethacrylate casting model of temporal bone: a simple technique for skull base research and education. <i>Skull Base Surg, 8, </i>17-21.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0122-9354201100010000200019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">L&oacute;pez, F. y Gonz&aacute;lez, A. (2004). Vertebroplast&iacute;a percut&aacute;nea. <i>Arch Neurocien, 9, </i>175-186.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0122-9354201100010000200020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Manzanilla, H., Gonz&aacute;lez, R., Garc&iacute;a, C., Echeverr&iacute;a, E. y Reyes, A. (1992). Pr&oacute;tesis testiculares de metilmetacrilato y silic&oacute;n elaborados en el Hospital General de M&eacute;xico. <i>Bol Col Mex Urol, 9, </i>19-31.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0122-9354201100010000200021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">McDuffee, L., Stover, S. y Taylor, K. (1997). An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae. <i>Vet Surg, 26, </i>126-136.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0122-9354201100010000200022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">McKee, M.D., Li-Bland, E.A., Wild, L.M., Schemitsch, E.H. (2010, 28 de ago.). A prospective, randomized clinical trial comparing an antibiotic-impregnated bioabsorbable bone substitute with standard antibiotic-impregnated cement beads in the treatment of chronic osteomyelitis and infected nonunion. <i>J Orthop Trauma, 24 </i>(8), 483-490.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0122-9354201100010000200023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Moreno, E., Moreno, L., Tecualt, R., Morf&iacute;n, A., Padilla, R., Alarc&oacute;n, C. y Amaya, R.A. (2003). Utilidad del metilmetacrilato en el tumor de c&eacute;lulas gigantes &oacute;seo. <i>Acta Ortop Mex, 17, </i>281-286.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S0122-9354201100010000200024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Muir, P., Johnson, K. y Markel, M. (1995). Area moment of inertia for comparison of implant crosssectional geometry and bending stiffness. <i>Vet Comp Orthop Traumatol, 8, </i>146-152.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0122-9354201100010000200025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Piermattei, D. y Flo, G. (1999). Fracturas: clasificaci&oacute;n, diagn&oacute;stico y tratamiento. Principios generales de diagn&oacute;stico y tratamiento de las fracturas, cojeras y enfermedades de las articulaciones. En: <i>Manual de ortopedia y reparaci&oacute;n de fracturas de peque&ntilde;os animales </i>(122-135). Madrid: McGraw Hill.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000135&pid=S0122-9354201100010000200026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Radcliffe, .R, L&oacute;pez, M., Turner, T., Watkins, J., Radcliffe, C. y Markel, M. (2001). An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of <i>diaphyseal </i>femur fractures in immature horses. <i>Vet Surg, 30, </i>179-190.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0122-9354201100010000200027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Rojas de la Rosa, G., Bisomo, A., Gonz&aacute;lez, A., Mor&oacute;n, M. y Saavedra, L. (2006). Tratamiento de fracturas de di&aacute;fisis de radio y cubito con placas LPC y LCDCP (estudio comparativo). <i>Acta Ortop Mex, 20, </i>97-101.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000137&pid=S0122-9354201100010000200028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Rouch, K. y McLaughlin, M. (1993). Fundamentos en el manejo de fracturas. <i>J Small Anim Pract, 34, </i>26-30.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0122-9354201100010000200029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Sears, B., Ostrum, R. y Litsky, A. (2004). Osteotom&iacute;as femorales transversales con separaci&oacute;n de 6 mm, fijadas mediante clavos supracondileos retr&oacute;grados cortos y largos en f&eacute;mures de cad&aacute;ver: estudio biomec&aacute;nico. <i>J Orthop Trauma, 18, </i>394-395.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S0122-9354201100010000200030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Slatter, D. (1989). M&eacute;todos de fijaci&oacute;n de las fracturas. En: <i>Texto de cirug&iacute;a de los peque&ntilde;os animales </i>(2274-2277, 2331-2351). Barcelona: Masson.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0122-9354201100010000200031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Smith, W. (2000). Reacciones de polimerizaci&oacute;n. En: <i>Fundamentos de la ciencia e ingenier&iacute;a de materiales </i>(328-329). Mc Graw Hill.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000141&pid=S0122-9354201100010000200032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Sod, G., Hubert, J., Martin, G. y Gill, M. (2005). An in vitro biomechanical comparison of a prototype equine metacarpal dynamic  compression plate fixation with double dynamic compression plate fixation of osteotomized equine third metacarpal bones. <i>Vet Surg, 34, </i>594-603.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0122-9354201100010000200033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Sod, G., Hubert, J., Martin, G. y Gill, M. (2006). An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones. <i>Vet Surg, 35, </i>634-642.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000143&pid=S0122-9354201100010000200034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Stiffler, K. (2004). Internal fracture fixation. <i>Clin Tech Small Anim Pract, 19, </i>105-113.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0122-9354201100010000200035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Tejwani, N., Park, S., Lesaka, K. y Kummer, F. (2005). La importancia de los tornillos de bloqueo distal en el enclavado retrograde de las fracturas osteoporoticas de f&eacute;mur distal: estudio biomec&aacute;nico en f&eacute;mures de cad&aacute;ver. <i>J Orthop Trauma, 19, </i>438.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000145&pid=S0122-9354201100010000200036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Timperley, A.J., Nusem, I., Wilson, K., Whitehouse, S.L., Buma, P. y Crawford, R.W. (2010, 30 de junio). A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model. <i>Acta Orthop. </i>&#91;en prensa&#93;.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0122-9354201100010000200037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Tominaga, K., Habu, M., Khanal, A., Mimori, Y., Yoshioka, I. y Fukada, J. (2006). Biomechanical evaluation of different types of rigid internal fixation techniques for subcondylar fractures. <i>J Oral Maxillofac Surg, 64, </i>1510-1516.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000147&pid=S0122-9354201100010000200038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Tovar, C., Cerrolaza, M. y Benday&aacute;n, J. (2002). Dise&ntilde;o y an&aacute;lisis por elementos finitos de placas para fijaci&oacute;n interna de fractura. En <i>M&eacute;todos num&eacute;ricos de ingenier&iacute;a V </i>(2-14). Ciudad: Semni.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0122-9354201100010000200039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Vandeweyer, E. y Gebhart, M. (2005). Treatment of humeral pathological fractures by internal fixation and methylmetacrylate inyection. <i>Eur J Surg Oncol, 23, </i>238-242.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000149&pid=S0122-9354201100010000200040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify">Vassallo, B. y Caruso, E. (1987). Reemplazo prot&eacute;sico con marlex y metilmetacrilato en grandes resecciones de pared tor&aacute;xica: trabajo experimental y cl&iacute;nico. <i>Rev Argent Cir, 52, </i>1-16.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0122-9354201100010000200041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Águila]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Manos]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Orlansky]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Todhunter]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Trotter]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Van der Muelen]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In Vitro biomechanical comparison of limited contact dynamic compression plate and holding compression plate]]></article-title>
<source><![CDATA[Vet Comp Orthop Traumatol]]></source>
<year>(200</year>
<month>5)</month>
<volume>4</volume>
<page-range>220-226</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ahmad]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Nanda]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Green]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Hui]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomecanical testing of the locking compression plate: when does the distance between bone and implant significanthy reduce construct stability]]></article-title>
<source><![CDATA[Vet Comp Orthop Traumatol]]></source>
<year>(200</year>
<month>7)</month>
<volume>3</volume>
<page-range>358-364</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beaupre]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Carter]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Dueland]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Caler]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Spengler]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A biomechanical assessment of plate fixation, with insufficient bony support]]></article-title>
<source><![CDATA[J Orthop Res]]></source>
<year>(198</year>
<month>8)</month>
<volume>6</volume>
<page-range>721</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beer]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Johnston]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Staab]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistema de unidades]]></article-title>
<source><![CDATA[Mecánica vectorial para ingenieros]]></source>
<year>(200</year>
<month>4)</month>
<publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bernarde]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Diop]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Laurel]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Viguier]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro biomechanical study of bon plate and interlocking nail in a canine diaphyseal femoral model]]></article-title>
<source><![CDATA[Vet Sur]]></source>
<year>(200</year>
<month>1)</month>
<volume>30</volume>
<page-range>397-408</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Börzei]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Mintal]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Horváth]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Koós]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Kocsis]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Nyárády]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative study of antibiotic containing polymethylmetacrylate capsules and beads.]]></article-title>
<source><![CDATA[Chemotherapy]]></source>
<year>(200</year>
<month>6)</month>
<volume>52</volume>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brinker]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Hohn]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Prieur]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fracture of the femur]]></article-title>
<source><![CDATA[Manual of internal fixation in small animals]]></source>
<year>(198</year>
<month>4)</month>
<page-range>118-133</page-range><publisher-name><![CDATA[Springer]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cavero]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilización del acrílico dental (metilmetacrilato) como barra estabilizadora-conectora para reducciones cerradas en fracturas de tibia/peroné o radio/cúbito en caninos]]></article-title>
<source><![CDATA[Rev Inv Vet]]></source>
<year>(200</year>
<month>5)</month>
<volume>16</volume>
<page-range>17-23</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cruz]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Arce]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Implantes craneales. XVII Reunión Nacional Médica del Instituto Nacional de Cancerología]]></article-title>
<source><![CDATA[Rev Inst Nac Canc]]></source>
<year>(200</year>
<month>0)</month>
<volume>46</volume>
<page-range>116-135</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Denny]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Tratamiento de las fracturas]]></article-title>
<source><![CDATA[Fundamentos de cirugía ortopédica canina]]></source>
<year>(198</year>
<month>2)</month>
<page-range>105-109</page-range><publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Acribia]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dueland]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Berglund]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Vanderby]]></surname>
<given-names><![CDATA[Jr]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Structural properties of interlocking nails, canine femora, and femurinterlocking nail constructs]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(199</year>
<month>6)</month>
<volume>25</volume>
<page-range>386-396</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fettig]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[McCarthy]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Kowaleski]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intertarsal and tarsometatarsal arthrodesis using 2.0/ 2.7mm or 2.7/3.5-mm hybrid dynamic compression plates]]></article-title>
<source><![CDATA[J A Anim Hosp Assoc]]></source>
<year>(200</year>
<month>2)</month>
<volume>38</volume>
<page-range>364-369</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Elementos de osteosíntesis de uso habitual en fracturas del esqueleto apendicular: evaluación radiólogica]]></article-title>
<source><![CDATA[Rev Chil Radiol]]></source>
<year>(200</year>
<month>5)</month>
<volume>11</volume>
<page-range>58-70</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Morando]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Mastropierro]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Méndez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[DiGiacomo]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Cocozzella]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Maletti]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Dapia]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Solis]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Guerrero]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Lupacchini]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Hiriart]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Villamil]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fracturas supracondíleas de fémur: estudio biomecánico comparativo entre el clavo endomedular retrógrado y el tornillo condíleo dinámico]]></article-title>
<source><![CDATA[Rev Asoc Argent Orto Traumatol]]></source>
<year>(200</year>
<month>0)</month>
<volume>65</volume>
<page-range>48-53</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Bravo]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Camarillo]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Vertebroplastía transpedicular percutánea con metilmetacrilato: Tratamiento del dolor por aplastamiento vertebral osteopénico]]></article-title>
<source><![CDATA[Acta Ortop Mex]]></source>
<year>(200</year>
<month>4)</month>
<volume>18</volume>
<page-range>82-85</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hulse]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Hyman]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Nori]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reduction in plate strain by addition of an intramedullary pin]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(199</year>
<month>7)</month>
<volume>26</volume>
<page-range>451-459</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jain]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Podworny]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Hearn]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Robin]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Schemitsch]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A biomecanical evaluation of different plates for fixation of canine radial osteotomies]]></article-title>
<source><![CDATA[Journal of Trauma Injury and Critical Care]]></source>
<year>(199</year>
<month>8)</month>
<volume>44</volume>
<page-range>193-197</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiménez]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Incrustaciones de acrílico: primer informe sobre 180 casos clínicos]]></article-title>
<source><![CDATA[Rev Univ de Zulia]]></source>
<year>(196</year>
<month>2)</month>
<volume>17</volume>
<page-range>35-67</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kubo]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Fukushima]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshimine]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Miki]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Hayakawa]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Methylmethacrylate casting model of temporal bone: a simple technique for skull base research and education]]></article-title>
<source><![CDATA[Skull Base Surg]]></source>
<year>(199</year>
<month>8)</month>
<volume>8</volume>
<page-range>17-21</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Vertebroplastía percutánea]]></article-title>
<source><![CDATA[Arch Neurocien]]></source>
<year>(200</year>
<month>4)</month>
<volume>9</volume>
<page-range>175-186</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manzanilla]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Reyes]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Prótesis testiculares de metilmetacrilato y silicón elaborados en el Hospital General de México]]></article-title>
<source><![CDATA[Bol Col Mex Urol]]></source>
<year>(199</year>
<month>2)</month>
<volume>9</volume>
<page-range>19-31</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McDuffee]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Stover]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(199</year>
<month>7)</month>
<volume>26</volume>
<page-range>126-136</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKee]]></surname>
<given-names><![CDATA[M.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Li-Bland]]></surname>
<given-names><![CDATA[E.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Wild]]></surname>
<given-names><![CDATA[L.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Schemitsch]]></surname>
<given-names><![CDATA[E.H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A prospective, randomized clinical trial comparing an antibiotic-impregnated bioabsorbable bone substitute with standard antibiotic-impregnated cement beads in the treatment of chronic osteomyelitis and infected nonunion]]></article-title>
<source><![CDATA[J Orthop Trauma]]></source>
<year>(201</year>
<month>0,</month>
<day> 2</day>
<volume>24</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>483-490</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreno]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Tecualt]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Morfín]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Alarcón]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Amaya]]></surname>
<given-names><![CDATA[R.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilidad del metilmetacrilato en el tumor de células gigantes óseo]]></article-title>
<source><![CDATA[Acta Ortop Mex]]></source>
<year>(200</year>
<month>3)</month>
<volume>17</volume>
<page-range>281-286</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muir]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Markel]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Area moment of inertia for comparison of implant crosssectional geometry and bending stiffness]]></article-title>
<source><![CDATA[Vet Comp Orthop Traumatol]]></source>
<year>(199</year>
<month>5)</month>
<volume>8</volume>
<page-range>146-152</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Piermattei]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Flo]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fracturas: clasificación, diagnóstico y tratamiento: Principios generales de diagnóstico y tratamiento de las fracturas, cojeras y enfermedades de las articulaciones.]]></article-title>
<source><![CDATA[Manual de ortopedia y reparación de fracturas de pequeños animales]]></source>
<year>(199</year>
<month>9)</month>
<page-range>122-135</page-range><publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[McGraw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Radcliffe]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Turner]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Watkins]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Radcliffe]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Markel]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of diaphyseal femur fractures in immature horses]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(200</year>
<month>1)</month>
<volume>30</volume>
<page-range>179-190</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rojas de la Rosa]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Bisomo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Morón]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Saavedra]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Tratamiento de fracturas de diáfisis de radio y cubito con placas LPC y LCDCP (estudio comparativo)]]></article-title>
<source><![CDATA[Acta Ortop Mex]]></source>
<year>(200</year>
<month>6)</month>
<volume>20</volume>
<page-range>97-101</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rouch]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[McLaughlin]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fundamentos en el manejo de fracturas]]></article-title>
<source><![CDATA[J Small Anim Pract]]></source>
<year>(199</year>
<month>3)</month>
<volume>34</volume>
<page-range>26-30</page-range></nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sears]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Ostrum]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Litsky]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Osteotomías femorales transversales con separación de 6 mm, fijadas mediante clavos supracondileos retrógrados cortos y largos en fémures de cadáver: estudio biomecánico]]></article-title>
<source><![CDATA[J Orthop Trauma]]></source>
<year>(200</year>
<month>4)</month>
<volume>18</volume>
<page-range>394-395</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Slatter]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Métodos de fijación de las fracturas]]></article-title>
<source><![CDATA[Texto de cirugía de los pequeños animales]]></source>
<year>(198</year>
<month>9)</month>
<page-range>2274-2277, 2331-2351</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Masson]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Reacciones de polimerización]]></article-title>
<source><![CDATA[Fundamentos de la ciencia e ingeniería de materiales]]></source>
<year>(200</year>
<month>0)</month>
<page-range>328-329</page-range><publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sod]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Hubert]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Martin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Gill]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro biomechanical comparison of a prototype equine metacarpal dynamic compression plate fixation with double dynamic compression plate fixation of osteotomized equine third metacarpal bones]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(200</year>
<month>5)</month>
<volume>34</volume>
<page-range>594-603</page-range></nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sod]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Hubert]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Martin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Gill]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones]]></article-title>
<source><![CDATA[Vet Surg]]></source>
<year>(200</year>
<month>6)</month>
<volume>35</volume>
<page-range>634-642</page-range></nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stiffler]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Internal fracture fixation]]></article-title>
<source><![CDATA[Clin Tech Small Anim Pract]]></source>
<year>(200</year>
<month>4)</month>
<volume>19</volume>
<page-range>105-113</page-range></nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tejwani]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Lesaka]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Kummer]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La importancia de los tornillos de bloqueo distal en el enclavado retrograde de las fracturas osteoporoticas de fémur distal: estudio biomecánico en fémures de cadáver]]></article-title>
<source><![CDATA[J Orthop Trauma]]></source>
<year>(200</year>
<month>5)</month>
<volume>19</volume>
<page-range>438</page-range></nlm-citation>
</ref>
<ref id="B37">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Timperley]]></surname>
<given-names><![CDATA[A.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Nusem]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Whitehouse]]></surname>
<given-names><![CDATA[S.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Buma]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Crawford]]></surname>
<given-names><![CDATA[R.W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model]]></article-title>
<source><![CDATA[Acta Orthop]]></source>
<year>(201</year>
<month>0,</month>
<day> 3</day>
</nlm-citation>
</ref>
<ref id="B38">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tominaga]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Habu]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Khanal]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Mimori]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshioka]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Fukada]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomechanical evaluation of different types of rigid internal fixation techniques for subcondylar fractures]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>(200</year>
<month>6)</month>
<volume>64</volume>
<page-range>1510-1516</page-range></nlm-citation>
</ref>
<ref id="B39">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tovar]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Cerrolaza]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bendayán]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Diseño y análisis por elementos finitos de placas para fijación interna de fractura]]></article-title>
<source><![CDATA[Métodos numéricos de ingeniería]]></source>
<year>(200</year>
<month>2)</month>
<volume>V</volume>
<page-range>2-14</page-range><publisher-loc><![CDATA[Ciudad ]]></publisher-loc>
<publisher-name><![CDATA[Semni]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B40">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vandeweyer]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Gebhart]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of humeral pathological fractures by internal fixation and methylmetacrylate inyection]]></article-title>
<source><![CDATA[Eur J Surg Oncol]]></source>
<year>(200</year>
<month>5)</month>
<volume>23</volume>
<page-range>238-242</page-range></nlm-citation>
</ref>
<ref id="B41">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vassallo]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Caruso]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Reemplazo protésico con marlex y metilmetacrilato en grandes resecciones de pared toráxica: trabajo experimental y clínico]]></article-title>
<source><![CDATA[Rev Argent Cir]]></source>
<year>(198</year>
<month>7)</month>
<volume>52</volume>
<page-range>1-16</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
