<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0123-921X</journal-id>
<journal-title><![CDATA[Tecnura]]></journal-title>
<abbrev-journal-title><![CDATA[Tecnura]]></abbrev-journal-title>
<issn>0123-921X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Distrital Francisco José de Caldas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0123-921X2015000200014</article-id>
<article-id pub-id-type="doi">10.14483/udistrital.jour.tecnura.2015.2.a13</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Obtención de modelos de carga compuestos en sistemas de potencia para análisis dinámico: revisión y aplicación]]></article-title>
<article-title xml:lang="en"><![CDATA[Composite load models in power systems for dynamical analysis: review and application]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Londoño]]></surname>
<given-names><![CDATA[Sandra Milena]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez García]]></surname>
<given-names><![CDATA[Luis Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mora Flórez]]></surname>
<given-names><![CDATA[Juan José]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Tecnológica de Pereira  ]]></institution>
<addr-line><![CDATA[Pereira ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Tecnológica de Pereira  ]]></institution>
<addr-line><![CDATA[Pereira ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Tecnológica de Pereira  ]]></institution>
<addr-line><![CDATA[Pereira ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2015</year>
</pub-date>
<volume>19</volume>
<numero>44</numero>
<fpage>171</fpage>
<lpage>189</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0123-921X2015000200014&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0123-921X2015000200014&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0123-921X2015000200014&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[En este artículo se presenta una revisión de las metodologías principales empleadas en la obtención de modelos de carga compuestos en sistemas eléctricos de potencia. Como estrategia de presentación de esta investigación, inicialmente se realiza la descripción y clasificación de las metodologías empleadas para obtener los modelos de carga compuestos, de sus diferentes modificaciones y de la utilización de nuevas herramientas durante los últimos años, de acuerdo con la información disponible en más de 60 referencias encontradas en las principales bases de datos. Las ventajas del modelo de carga compuesto se comprueban en la parte final del artículo, en donde se compara su comportamiento con el modelo de carga estático y se hace un análisis de la capacidad de generalización ante diferentes perturbaciones del sistema de potencia. Este trabajo sirve como una referencia útil en la discusión relacionada con aplicaciones del modelado de carga en los sistemas eléctricos de potencia.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[This paper is oriented to present a review of different approaches commonly applied to obtain composite load models used in electric power system studies. As presentation strategy, there is initially a detailed description and classification of the methodologies used to obtain composite load models, their different modifications and the use of new tools during the last years, according to the available information from more than 60 references found in databases. The advantages of composite load model are evaluated and highlighted at the final part of this paper, where its behavior is compared to the static load model and an analysis of the generalization capability considering different power system disturbances is presented. This research work is a useful reference in the discussion associated to applications of load modeling in electric power systems.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[estimación de parámetros]]></kwd>
<kwd lng="es"><![CDATA[modelado de carga]]></kwd>
<kwd lng="es"><![CDATA[simulación de sistemas de potencia]]></kwd>
<kwd lng="es"><![CDATA[sistemas eléctricos de potencia]]></kwd>
<kwd lng="en"><![CDATA[electric power systems]]></kwd>
<kwd lng="en"><![CDATA[load modeling]]></kwd>
<kwd lng="en"><![CDATA[parameter estimation]]></kwd>
<kwd lng="en"><![CDATA[power system simulation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">     <p>DOI: <a href="http://dx.doi.org/10.14483/udistrital.jour.tecnura.2015.2.a13" target="_blank">http://dx.doi.org/10.14483/udistrital.jour.tecnura.2015.2.a13</a> </p>      <p align="center"><font size="4"><b>Obtenci&oacute;n de modelos de carga compuestos en sistemas de potencia para an&aacute;lisis din&aacute;mico: revisi&oacute;n y aplicaci&oacute;n</b></font></p>     <p align="center"><font size="3"><b>Composite load models in power systems for dynamical analysis: review and application</b></font></p>     <p align="center"><b>Sandra Milena P&eacute;rez Londo&ntilde;o</b>*,    <br> <b>Luis Fernando Rodr&iacute;guez Garc&iacute;a</b>**,    <br> <b>Juan Jos&eacute; Mora Fl&oacute;rez</b>***</p>     <p>* Ingeniera electricista, mag&iacute;ster en Ingenier&iacute;a El&eacute;ctrica, doctora en Ingenier&iacute;a. Docente de la Universidad Tecnol&oacute;gica de Pereira. Pereira, Colombia. Contacto: <I><a href="mailto:saperez@utp.edu.co">saperez@utp.edu.co</a></I>    <br> ** Ingeniero electricista, mag&iacute;ster en Ingenier&iacute;a El&eacute;ctrica. Investigador de la Universidad Tecnol&oacute;gica de Pereira. Pereira, Colombia. Contacto: <I><a href="mailto:luferodriguez@utp.edu.co">luferodriguez@utp.edu.co</a></I>    <br> *** Ingeniero electricista, mag&iacute;ster en Potencia El&eacute;ctrica, mag&iacute;ster en Tecnolog&iacute;as de la Informaci&oacute;n, doctor en Tecnolog&iacute;as de la Informaci&oacute;n; docente de la Universidad Tecnol&oacute;gica de Pereira. Pereira, Colombia. Contacto: <I><a href="mailto:jjmora@utp.edu.co">jjmora@utp.edu.co</a></I></p>     ]]></body>
<body><![CDATA[<p>Fecha de recepci&oacute;n: 12 de marzo de 2014 Fecha de aceptaci&oacute;n: 19 de enero de 2015 </p>     <p><B>Citation / Para citar este art&iacute;culo:</B> P&eacute;rez Londo&ntilde;o, S. M., Rodr&iacute;guez Garc&iacute;a, L. F., &amp; Mora Fl&oacute;rez, J. J. (2015). Obtenci&oacute;n de modelos de carga compuestos en sistemas de potencia para an&aacute;lisis din&aacute;mico: revisi&oacute;n y aplicaci&oacute;n. <I>Revista Tecnura, 19</I>(44), 171-189. doi: <a href="http://dx.doi.org/10.14483/udistrital.jour.tecnura.2015.2.a13" target="_blank">http://dx.doi.org/10.14483/udistrital.jour.tecnura.2015.2.a13</a> </p> <hr>      <p><B><font size="3">Resumen</font></B></p>     <p>En este art&iacute;culo se presenta una revisi&oacute;n de las metodolog&iacute;as principales empleadas en la obtenci&oacute;n de modelos de carga compuestos en sistemas el&eacute;ctricos de potencia. Como estrategia de presentaci&oacute;n de esta investigaci&oacute;n, inicialmente se realiza la descripci&oacute;n y clasificaci&oacute;n de las metodolog&iacute;as empleadas para obtener los modelos de carga compuestos, de sus diferentes modificaciones y de la utilizaci&oacute;n de nuevas herramientas durante los &uacute;ltimos a&ntilde;os, de acuerdo con la informaci&oacute;n disponible en m&aacute;s de 60 referencias encontradas en las principales bases de datos. Las ventajas del modelo de carga compuesto se comprueban en la parte final del art&iacute;culo, en donde se compara su comportamiento con el modelo de carga est&aacute;tico y se hace un an&aacute;lisis de la capacidad de generalizaci&oacute;n ante diferentes perturbaciones del sistema de potencia. Este trabajo sirve como una referencia &uacute;til en la discusi&oacute;n relacionada con aplicaciones del modelado de carga en los sistemas el&eacute;ctricos de potencia.</p>     <p><b>Palabras clave</b>: estimaci&oacute;n de par&aacute;metros, modelado de carga, simulaci&oacute;n de sistemas de potencia, sistemas el&eacute;ctricos de potencia.</p> <hr>     <p><b><font size="3">Abstract</font></b></p>     <p>This paper is oriented to present a review of different approaches commonly applied to obtain composite load models used in electric power system studies. As presentation strategy, there is initially a detailed description and classification of the methodologies used to obtain composite load models, their different modifications and the use of new tools during the last years, according to the available information from more than 60 references found in databases. The advantages of composite load model are evaluated and highlighted at the final part of this paper, where its behavior is compared to the static load model and an analysis of the generalization capability considering different power system disturbances is presented. This research work is a useful reference in the discussion associated to applications of load modeling in electric power systems.</p>     <p><b>Keywords</b>: electric power systems, load modeling, parameter estimation, power system simulation.</p> <hr>     <p><font size="3"><B>Introducci&oacute;n</B></font></p>      <p>En los sistemas el&eacute;ctricos de potencia el modelado de la carga representa un gran desaf&iacute;o, debido a su naturaleza compleja y variante en el tiempo, comparativamente con otros componentes como generadores o l&iacute;neas de transmisi&oacute;n, para los cuales existen modelos ampliamente analizados y empleados satisfactoriamente. </p>      ]]></body>
<body><![CDATA[<p>En los &uacute;ltimos treinta a&ntilde;os se ha realizado una considerable cantidad de investigaciones en el &aacute;rea del modelado de carga, incluyendo tres recomendaciones del grupo de trabajo en modelado de IEEE (IEEE Task Force on Load Representation for Dynamic Performances, 1993) (IEEE Task Force on Load Representation for Dynamic Performances, 1995a) (IEEE Task Force on Load Representation for Dynamic Performances, 1995b), adem&aacute;s de muchos art&iacute;culos en donde se han presentado diversas propuestas en cuanto a modelos matem&aacute;ticos, enfoques y metodolog&iacute;as. Aun as&iacute;, esta sigue siendo un &aacute;rea de constante y vigente investigaci&oacute;n. Actualmente, la inclusi&oacute;n de nuevos tipos de cargas en los sistemas el&eacute;ctricos de potencia (cargas electr&oacute;nicas, generaci&oacute;n distribuida, entre otras), tambi&eacute;n ha influido en que esta sea un &aacute;rea de creciente inter&eacute;s por parte de los investigadores, para definir modelos que se adapten a las caracter&iacute;sticas propias de este tipo de cargas (Department of Energy and Climate Change (DECC), 2010). </p>     <p>Para la definici&oacute;n de los modelos de carga se han considerado tanto las caracter&iacute;sticas de las cargas (est&aacute;ticas o din&aacute;micas), como las metodolog&iacute;as que se han empleado para su obtenci&oacute;n (enfoque basado en componentes o en mediciones) (Kundur, 1993). Para el caso espec&iacute;fico del modelado din&aacute;mico de carga, se han empleado los modelos de recuperaci&oacute;n exponencial y el modelo compuesto, siendo este &uacute;ltimo uno de los m&aacute;s analizados, debido a que m&aacute;s de 60% de la potencia total demandada en los sistemas el&eacute;ctricos de potencia corresponde a los motores y, por tanto, es razonable incluir su comportamiento din&aacute;mico en el modelo de la carga para estudios de estabilidad en sistemas el&eacute;ctricos (Ornata &amp; Uemura, 1998) (Ma, He, &amp; Hill, 2006). </p>     <p>En el transcurso de los &uacute;ltimos a&ntilde;os se han empleado diversas t&eacute;cnicas para el modelado de carga, desde metodolog&iacute;as que abordan la inteligencia artificial (Chen &amp; Mohler, 2003) (Wang, Li, Su, &amp; Xia, 2006) (Abdelaziz, Badr, &amp; Younes, 2007) (Li, Wang, &amp; Li, 2008), hasta metodolog&iacute;as de optimizaci&oacute;n (Wu, Wen, Nuttall, Shimmin, &amp; Cheng, 2003) (Wen, Jiang, Wu, &amp; Cheng, 2003) (Shi &amp; He, 2003) (Knyazkin, Ca&ntilde;izares, &amp; S&ouml;der, 2004) (Ju, y otros, 2007), que mejoran las propuestas cl&aacute;sicas empleadas en la implementaci&oacute;n de los modelos. Sin embargo, del trabajo de revisi&oacute;n (Milanovic, Yamashita, Martinez, Djokie, &amp; Korunovic, 2013)<I>, </I>se observa c&oacute;mo la utilizaci&oacute;n de los modelos de carga din&aacute;micos es bastante baja, comparativamente con los modelos est&aacute;ticos, a pesar de que su imposibilidad de reflejar las condiciones reales de la carga ya ha sido analizada y reportada en una gran cantidad de art&iacute;culos (Mauricio &amp; Semlyen, 1972). </p>     <p>Por otra parte, debido al auge de los sistemas de monitorizaci&oacute;n de &aacute;rea amplia (WAMS), la tendencia en el modelado de carga est&aacute; encaminada a la incorporaci&oacute;n de la informaci&oacute;n recopilada por estos sistemas para el desarrollo y perfeccionamiento de los modelos de carga en los sistemas el&eacute;ctricos. La disponibilidad de estas mediciones en los sistemas el&eacute;ctricos de potencia permite monitorizar permanentemente el comportamiento de las cargas ante los eventos que ocurren en la operaci&oacute;n del sistema. Sin embargo, estas mediciones tambi&eacute;n se pueden utilizar para prop&oacute;sitos de sintonizaci&oacute;n de modelos de carga, empleando metodolog&iacute;as de estimaci&oacute;n. En la representaci&oacute;n de la carga para prop&oacute;sitos de an&aacute;lisis din&aacute;mico, los modelos compuestos siguen siendo ampliamente aplicados y aceptados, dado que sus resultados presentan mejor precisi&oacute;n en comparaci&oacute;n con otros modelos de carga, como los modelos con ecuaciones de diferencia (Shi, Peng, &amp; Liu, 2012). </p>      <p>Ante este panorama, es importante contar con un an&aacute;lisis completo de la bibliograf&iacute;a disponible, que recoja informaci&oacute;n sobre el estado del arte de las diferentes metodolog&iacute;as empleadas en la obtenci&oacute;n de modelos de carga din&aacute;micos, con el fin de proponer nuevas estrategias que suplan o re-fuercen los enfoques tradicionales. Para tal fin, en este art&iacute;culo se hace una revisi&oacute;n actualizada sobre las diferentes metodolog&iacute;as empleadas en la obtenci&oacute;n de modelos din&aacute;micos de carga, espec&iacute;ficamente relacionadas con el modelo de carga compuesto. Adem&aacute;s, y como complemento de la investigaci&oacute;n, se presenta la aplicaci&oacute;n de una metodolog&iacute;a basada en mediciones para obtener un modelo de carga compuesto, basada en un algoritmo evolutivo; el desempe&ntilde;o del modelo obtenido se compara con un modelo de carga est&aacute;tico y adicionalmente se analiza su capacidad de generalizaci&oacute;n ante diferentes condiciones de operaci&oacute;n. </p>      <p><B>CONCEPTOS B&Aacute;SICOS SOBRE MODELOS DE CARGA </b></p>     <p><b>Definici&oacute;n de carga </b></p>      <p>De acuerdo con (Rifaat, 2004), un elemento de carga se define como un dispositivo o componente de un sistema de potencia que consume, genera o controla la potencia real o reactiva; es sensible ante variaciones transitorias, din&aacute;micas o de estado estable en la tensi&oacute;n de la barra donde se encuentra conectada con otros elementos, y este a su vez a una fuente de energ&iacute;a el&eacute;ctrica. Es importante tener en cuenta que la carga no solo la conforman los dispositivos (como l&aacute;mparas, motores, sistemas de aire acondicionado, por mencionar algunos), sino tambi&eacute;n hacen parte los transformadores a nivel de sub-transmisi&oacute;n, alimentadores primarios y secundarios, capacitores en paralelo y reguladores de tensi&oacute;n, entre otros. </p>     <p><b><B>Clasificaci&oacute;n de modelos de carga </b></b></p>      <p>Para representar el comportamiento de la carga se emplean modelos, que mediante expresiones matem&aacute;ticas describen las caracter&iacute;sticas de la potencia activa y reactiva de la carga respecto a la variaci&oacute;n de la tensi&oacute;n y la frecuencia en la barra donde se encuentra conectada (Choi B. , y otros, 2006). Por simplificaci&oacute;n, en varios estudios la frecuencia se considera constante y por tanto, los modelos solo dependen de la tensi&oacute;n (Kundur, 1993). De acuerdo con la forma de las expresiones matem&aacute;ticas, los modelos de las cargas se clasifican en modelos est&aacute;ticos y modelos din&aacute;micos. El comportamiento en el dominio del tiempo de las cargas est&aacute;ticas se representa adecuadamente por una funci&oacute;n algebraica de la tensi&oacute;n y/o la frecuencia. De esta forma, se describen los modelos exponencial y polinomial o ZIP (Z, impedancia constante, I, corriente constante I y P, potencia constante) (Kundur, 1993). Las cargas din&aacute;micas requieren un modelado expl&iacute;cito con ecuaciones que reflejen la dependencia de las variables con el tiempo, como en el caso de motores de inducci&oacute;n y s&iacute;ncronos. Generalmente para su representaci&oacute;n se utilizan ecuaciones de diferencia y/o diferenciales, como el modelo utilizado en la <a href="#ec1">ecuaci&oacute;n (1)</a>. </p>     ]]></body>
<body><![CDATA[<p align="center"><a name="ec1"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec1.jpg"></p>      <p>donde <I>P</I><Sub><I>s</I></Sub> y <I>Q</I><Sub><I>s</I></Sub> representan las potencias real y re-activa de la carga en estado estable como funci&oacute;n de la tensi&oacute;n <I>V</I>. A su vez, <I>P</I><Sub><I>t </I></Sub>y <I>Q</I><Sub><I>t </I></Sub>representan las potencias en estado transitorio como funci&oacute;n de la tensi&oacute;n. <I>T</I><Sub><I>p</I></Sub> y <I>T</I><Sub><I>q</I></Sub> son las constantes de tiempo para las potencias activa y reactiva, <I>x</I> e <I>y</I> son las variables de estado para las potencias activa y reactiva, respectivamente. </p>      <p>Entre los modelos de carga din&aacute;micos se encuentran el de recuperaci&oacute;n exponencial y el modelo compuesto (Kundur, 1993). De acuerdo con la naturaleza y caracter&iacute;sticas de las cargas, el primero se emplea generalmente para cargas que no responden inmediatamente ante variaciones en la tensi&oacute;n como equipos de calefacci&oacute;n e iluminaci&oacute;n, y el segundo se aplica para cargas con un considerable n&uacute;mero de motores de inducci&oacute;n (Maitra, Gaikwad, Pourbeik, &amp; Brooks, 2008) (Choi B. , y otros, 2006). En los sistemas el&eacute;ctricos de potencia, la mayor&iacute;a de componentes din&aacute;micos son motores de inducci&oacute;n, los cuales representan un alto porcentaje de la potencia total consumida por las cargas. Por tanto, una representaci&oacute;n mediante modelos compuestos puede aproximarse a la composici&oacute;n real de la carga, dado que el modelo compuesto hace parte de aquellos modelos que tienen un claro significado f&iacute;sico (al incluir en su composici&oacute;n un motor de inducci&oacute;n conectado en paralelo con una carga est&aacute;tica), comparativamente con modelos de carga de tipo &ldquo;caja negra&rdquo;, que no lo hacen (Song, Cotilla-Sanchez, &amp; Brekken, 2013). Por otra parte, las aplicaciones desarrolladas con el modelo compuesto, han demostrado una buena descripci&oacute;n del comportamiento din&aacute;mico de la carga, espec&iacute;ficamente para la respuesta de la potencia reactiva en estudios relacionados con estabilidad, comparativamente con modelos din&aacute;micos de carga t&iacute;picos (Peng, Yan-hong, Guoqiang, &amp; Rui, 2005). Las razones anteriores hacen del modelo de carga compuesto uno de los m&aacute;s empleados y por tanto, esta revisi&oacute;n bibliogr&aacute;fica se centra en su estudio. </p>     <p>Este modelo, a diferencia de los otros modelos din&aacute;micos de carga, ha sido uno de los m&aacute;s utilizados, debido a que tiene un claro significado f&iacute;sico. En su estructura combina un modelo ZIP, para representar el comportamiento est&aacute;tico de la carga, con un modelo de tercer orden de motor de inducci&oacute;n que representa el componente din&aacute;mico de la carga, que generalmente se conectan en paralelo, como se ilustra en la <a href="#f1">figura 1</a>. </p>     <p align="center"><a name="f1"></a><img src="img/revistas/tecn/v19n44/v19n44a14f1.jpg"></p>      <p><b><B>Modelo de carga compuesto (Shi &amp; He, 2003) </b></b></p>      <p>Un modelo de carga compuesto combina en paralelo un modelo est&aacute;tico ZIP con un modelo de tercer orden de motor de inducci&oacute;n, como se ilustra en la <a href="#f1">figura 1</a>, y se define como modelo de carga ZIP-IM. Es importante aclarar que a nivel de distribuci&oacute;n, en la revision blibliogr&aacute;fica se encuentra la definici&oacute;n de un modelo compuesto como una combinaci&oacute;n solamente de potencia constante, corriente constante e impedancia constante (Kalesar &amp; Seifi, 2010) (Abul'Wafa, 2012). El modelo considerado en este art&iacute;culo se centra en la definici&oacute;n inicial. </p>      <p>La potencia total consumida en la barra de carga de la <a href="#f1">figura 1</a> se puede calcular como una combinaci&oacute;n de una parte est&aacute;tica y una din&aacute;mica del modelo, seg&uacute;n la <a href="#ec2">ecuaci&oacute;n (2)</a>. </p>     <p align="center"><a name="ec2"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec2.jpg"></p>      <p>Con <I>P</I><Sub><I>0 </I></Sub>y <I>Q</I><Sub><I>0</I></Sub> corresponden a la carga activa y re-activa inicial de la barra respectivamente, y <I>P<sub><I>motor0 </I></sub></I> y <I>Q<sub><I>motor0 </I></sub></I>son las potencias activa y reactiva inicial  consumida por el motor. </p>      ]]></body>
<body><![CDATA[<p>La componente est&aacute;tica puede ser modelada a partir de la <a href="#ec3">ecuaci&oacute;n (3)</a>. </p>     <p align="center"><a name="ec3"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec3.jpg"></p>      <p>Donde <I>P<sub><I>baseZIP</I></sub></I>, <I>Q<sub>baseZIP</sub></I> representan la potencia activa y reactiva de la carga est&aacute;tica en estado estacionario, <I>V</I><Sub><I>0</I></Sub> es la tensi&oacute;n de la carga en estado estacionario, <I>a</I><Sub><I>0</I></Sub> y <I>b</I><Sub><I>0</I></Sub> son las componentes asociadas a carga de potencia constante, <I>a</I><Sub><I>1</I></Sub> y <I>b</I><Sub><I>1</I></Sub> son las componentes asociadas a carga de corriente constante y <I>a</I><Sub><I>2 </I></Sub>y <I>b</I><Sub><I>2 </I></Sub>son las componentes asociadas a carga de impedancia constante. Adicionalmente, se debe cumplir la <a href="#ec4">ecuaci&oacute;n (4)</a>. </p>     <p align="center"><a name="ec4"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec4.jpg"></p>      <p>Para la componente din&aacute;mica del modelo se emplea un modelo de tercer orden de un motor de inducci&oacute;n, cuyas ecuaciones se presentan en la <a href="#ec5">ecuaci&oacute;n (5)</a>. </p>     <p align="center"><a name="ec5"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec5.jpg"></p>     <p>Donde las corrientes de eje d y eje q y algunos par&aacute;metros se presentan en la <a href="#ec6">ecuaci&oacute;n (6)</a>. </p>     <p align="center"><a name="ec6"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec6.jpg"></p>      <p>Donde E'<sub>d</sub></Sub> es la fuerza electromotriz interna en  el eje directo <I>d</I>, E'<sub>d</sub></Sub> es la fuerza electromotriz interna en el eje en cuadratura <I>q</I>, <I>&omega;</I> es la velocidad del rotor, <I>I</I><Sub><I>d</I></Sub> e <I>I</I><Sub><I>q</I></Sub> son las corrientes del estator en el eje <I>d </I>y <I>q </I>respectivamente, <I>U</I><Sub><I>d </I></Sub>y <I>U</I><Sub><I>q </I></Sub>son las tensiones en terminales del eje <I>d</I> y del eje <I>q</I>. <I>R<sub>s</sub> </I>, <I>X<sub>s</sub> </I>, <I>X<sub>m</sub> </I>, <I>R<sub>r</sub> </I>y <I>X<sub>r</sub> </I>son  la resistencia del estator, la reactancia del estator, reactancia de magnetizaci&oacute;n, resistencia del rotor y reactancia del rotor respectivamente, y finalmente, <I>H</I> corresponde al coeficiente de inercia. </p>      <p>La potencia activa y reactiva consumida por el motor puede calcularse seg&uacute;n la <a href="#ec7">ecuaci&oacute;n (7)</a>. </p>     ]]></body>
<body><![CDATA[<p align="center"><a name="ec7"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec7.jpg"></p>      <p>De acuerdo con las <a href="#ec2">ecuaciones (2)</a> a <a href="#ec7">(7)</a>, el modelo de carga compuesto requiere 11 par&aacute;metros para su definici&oacute;n &#91;<I>R<sub>r</sub>, X<sub>s</sub>, X<sub>r</sub>, R<sub>r</sub>, X<sub>0</sub>, H<sub>0</sub>, T<sub>2</sub>, a, a, b</I><Sub><I>0</I></Sub><I>,</I> <I>b</I><Sub><I>2</I></Sub>&#93;, los cuales se pueden obtener mediante algo-ritmos de estimaci&oacute;n que emplean mediciones de tensiones o potencias del sistema o se definen <I>a priori</I> empleando par&aacute;metros t&iacute;picos (Pereira, y otros, 2002) (IEEE Task Force on Load Representation for Dynamic Performances, 1995b). A continuaci&oacute;n se presenta una revisi&oacute;n bibliogr&aacute;fica en donde se resaltan las metodolog&iacute;as m&aacute;s representativas basadas en mediciones, empleadas para la obtenci&oacute;n del modelo de carga descrito. </p>      <p><B>REVISI&Oacute;N BIBLIOGR&Aacute;FICA DEL MODELO DE CARGA COMPUESTO </b></p>     <p><b>Evoluci&oacute;n del modelo de carga compuesto </b></p>      <p>Ante la pobre representatividad y la mala precisi&oacute;n de los modelos de carga est&aacute;ticos empleados para reproducir el comportamiento din&aacute;mico en los sistemas reales, surgieron diferentes modelos, entre ellos el modelo compuesto. Esta situaci&oacute;n se evidenci&oacute; en los estudios de validaci&oacute;n realizados sobre los eventos del 10 de agosto de 1996 y el 4 de agosto de 2000 ocurridos en Estados Unidos. Ambos eventos estuvieron relacionados con la aparici&oacute;n de oscilaciones no amortiguadas, despu&eacute;s de la salida de algunos elementos del sistema (l&iacute;neas, generadores) y una serie de eventos en cascada, que condujeron posteriormente a un colapso y al aislamiento de grandes partes del sistema. Dichos eventos demostraron la necesidad de replantear los modelos de generadores y de modelos de carga est&aacute;ticos existentes en el WSCC (Western Systems Coordinating Council), por modelos din&aacute;micos, ya que con la representaci&oacute;n original no es posible obtener una correlaci&oacute;n entre los registros de datos y las simulaciones (Kosterev, Taylor, &amp; Mittelstadt, 1999) (Pereira, Kosterev, Mackin, Davies, Undrill, &amp; Zhu, 2002). En (Pereira, y otros, 2002) se propuso un modelo de carga compuesto (80% parte est&aacute;tica y 20% motor de inducci&oacute;n), el cual fue adoptado y utilizado para todas las cargas en el sistema WSCC. Los autores concluyen que la utilizaci&oacute;n de este modelo no se puede generalizar y que es susceptible de ser mejorado. La actualizaci&oacute;n del modelo anterior se hizo unos a&ntilde;os m&aacute;s tarde en (Kosterev &amp; Meklin, 2006) y (Kosterev, y otros, 2008), por parte del WECC (Western Electricity Coordinating Council, sucesor del WSCC). All&iacute; se presenta un mejoramiento sustancial respecto al modelo anterior, en cuanto a la representaci&oacute;n detallada de los componentes de carga en una barra dada. Entre sus ventajas m&aacute;s representativas se encuentra la inclusi&oacute;n en el modelo, de una impedancia para representar la distancia el&eacute;ctrica entre la barra de transmisi&oacute;n y el usuario final. Adicionalmente, se considera la representaci&oacute;n de la diversidad en la composici&oacute;n y en las caracter&iacute;sticas din&aacute;micas de varios equipos, mediante la inclusi&oacute;n de cuatro tipos de motores. En la <a href="#f2">figura 2</a> se ilustra la estructura del modelo mejorado. </p>     <p align="center"><a name="f2"></a><img src="img/revistas/tecn/v19n44/v19n44a14f2.jpg"></p>     <p>Existen numerosas referencias en donde se ha empleado el modelo de carga compuesto, as&iacute; como tambi&eacute;n muchas metodolog&iacute;as empleadas para su ajuste. Por ejemplo, se ha empleado el enfoque basado en componentes o en mediciones para obtener los par&aacute;metros del modelo compuesto (Kundur, 1993). Para obtener un modelo de carga empleando el enfoque basado en componentes se requiere conocer en forma detallada la composici&oacute;n y la mezcla de la carga, lo cual generalmente es dif&iacute;cil de obtener. Por otra parte, el enfoque basado en mediciones es mucho m&aacute;s vers&aacute;til, debido a que emplea las medidas obtenidas en el sistema para estimar los par&aacute;metros de una estructura definida previamente. A continuaci&oacute;n se presentan algunas de las referencias m&aacute;s sobresalientes, que han empleado el enfoque basado en mediciones en la obtenci&oacute;n de los modelos de carga compuestos, en los &uacute;ltimos a&ntilde;os. </p>      <p><b><B>Obtenci&oacute;n del modelo de carga compuesto empleando mediciones </b></b></p>      <p>En este enfoque se utilizan las mediciones adquiridas de la barra de carga para obtener el modelo. Inicialmente se selecciona una estructura para representar el comportamiento de la carga, cuyos par&aacute;metros son desconocidos. Posteriormente se emplea una metodolog&iacute;a de estimaci&oacute;n para determinar los par&aacute;metros mediante la minimizaci&oacute;n de la diferencia entre la respuesta del modelo estimado y las mediciones de la barra de carga (IEEE Task Force on Load Representation for Dynamic Performances, 1993) (Kundur, 1993). Las metodolog&iacute;as que se han empleado para estimar los par&aacute;metros del modelo compuesto de carga han sido numerosas, tanto lineales como no lineales, entre ellas se encuentran: algoritmos de m&iacute;nimos cuadrados, t&eacute;cnicas de optimizaci&oacute;n lineal y no lineal, algo-ritmos evolutivos (Ju, y otros, 2007), entre otros. A continuaci&oacute;n se presentan algunas de ellas. </p>      <p>Empleando el enfoque basado en mediciones y una metodolog&iacute;a mixta de t&eacute;cnicas de identificaci&oacute;n no lineal con modelos de predicci&oacute;n del error, en (Wang, Jiang, Chang, &amp; Liu, 1994) se desarroll&oacute; un modelo de carga compuesto dependiente de la frecuencia, cuyos componentes son un circuito RC en paralelo con un circuito equivalente de un motor de inducci&oacute;n. Sin embargo, en este art&iacute;culo no se hizo una comparaci&oacute;n del desempe&ntilde;o entre el modelo compuesto dependiente de la frecuencia y el modelo convencional compuesto ante grandes excursiones de frecuencia, tensi&oacute;n y corriente, impidiendo verificar la validez del modelo. </p>      ]]></body>
<body><![CDATA[<p>En (Kao, 2001) se analiza el impacto de diversos modelos de carga (modelo din&aacute;mico de carga, compuesto y exponencial), sobre el amortiguamiento de las oscilaciones inestables de baja frecuencia ocurridas en el sistema de potencia de Taiw&aacute;n, mediante el an&aacute;lisis de los valores propios. All&iacute; se demuestra que el modelo compuesto, en comparaci&oacute;n con los otros modelos, permite un mayor amortiguamiento de las oscilaciones. </p>     <p>Ante la influencia de los motores de inducci&oacute;n en el comportamiento din&aacute;mico y transitorio de los sistemas el&eacute;ctricos, se han empleado t&eacute;cnicas para modelar un conjunto de estos elementos, mediante la obtenci&oacute;n de un modelo equivalente por medio de la agregaci&oacute;n de motores (Nozari, Kankam, &amp; Price, 1987). Pero aun as&iacute;, no se ha documentado por qu&eacute;, mediante la representaci&oacute;n de la carga din&aacute;mica por un motor de inducci&oacute;n o la combinaci&oacute;n de este con una impedancia constante en paralelo, no se consigue una respuesta din&aacute;mica adecuada de la potencia reactiva (Xin-ran, Ren-mu, &amp; Zhou, 1999) (Wei-guo, Ren-mu, &amp; Tie-Qiang, 2002). Por esta raz&oacute;n, los autores en (Shi &amp; He, 2003) proponen un modelo de carga compuesto mejorado, en donde consideran para la parte est&aacute;tica un modelo ZIP, junto con un modelo de un motor de inducci&oacute;n, que se valida con datos obtenidos de registros de perturbaciones transitorias. </p>     <p>En (De Tuglie, Patrono, &amp; Torelli, 2005) se identifican los par&aacute;metros de un modelo compuesto de carga heterog&eacute;neo en su composici&oacute;n (carga dependiente del voltaje como parte est&aacute;tica y un motor de inducci&oacute;n como parte din&aacute;mica), utilizando mediciones de tensi&oacute;n en los nodos de carga para el modelo adaptativo, desarrollado de acuerdo con la teor&iacute;a de la sensibilidad. La metodolog&iacute;a requiere que el sistema de potencia sea excitado por perturbaciones derivadas de eventos normales del sistema y por contingencias. </p>     <p>Uno de los primeros art&iacute;culos en donde se construye un modelo de carga compuesto (ZIP y motor de inducci&oacute;n) mejorado, basado en mediciones de campo corresponde a (He, Ma, &amp; Hill, 2006), ya que la mayor&iacute;a de las aplicaciones del modelo empleaban par&aacute;metros por defecto, obtenidos generalmente del software LOADSYN (General Electric Company, 1987). La metodolog&iacute;a que se propone determina los par&aacute;metros del modelo empleando la t&eacute;cnica de identificaci&oacute;n multi-curva y adicionalmente se analiza la capacidad de generalizaci&oacute;n de este modelo, mediante la t&eacute;cnica de validaci&oacute;n cruzada. </p>     <p>En (Choi B.-K. , y otros, 2006) se presenta el desarrollo de tres modelos de carga compuestos, GZIP (modelo gen&eacute;rico ZIP &ndash; motor de inducci&oacute;n de tercer orden), Exp-IM (modelo exponencial &ndash; motor de inducci&oacute;n) y Z-IM (carga est&aacute;tica como impedancia constante y motor de inducci&oacute;n), cuyos par&aacute;metros fueron estimados con el algoritmo de m&iacute;nimos cuadrados no lineal. Los autores concluyen que existen ciertos par&aacute;metros que se ven afectados por las condiciones de carga del motor de inducci&oacute;n, por lo cual es necesaria su actualizaci&oacute;n ante diferentes condiciones de operaci&oacute;n. Aunque los tres modelos reproducen satisfactoriamente los comportamientos de potencia activa y reactiva, el modelo GZIP entrega los mejores resultados. </p>     <p>Uno de los problemas y retos que se presentan con el enfoque basado en mediciones en la obtenci&oacute;n del modelo de carga radica en la gran cantidad de informaci&oacute;n que se registra y concentra en las bases de datos del sistema. Por tanto, es necesario disponer de herramientas de depuraci&oacute;n que permitan reducir el esfuerzo computacional. En (Ma, He, &amp; Hill, 2006), los autores proponen un modelo de carga basado en vectores de soporte que permiten obtener modelos con una gran  capacidad de generalizaci&oacute;n, a partir de solo un peque&ntilde;o subconjunto de las bases de datos. </p>      <p>En (Maitra, Gaikwad, Pourbeik, &amp; Brooks, 2008), se emple&oacute; una metodolog&iacute;a param&eacute;trica no lineal, para definir estructuras compuestas del tipo (ZIP + motor de inducci&oacute;n). Los autores concluyen que los modelos est&aacute;ticos no son apropiados para capturar la respuesta real del sistema; a su vez, que los modelos de carga obtenidos en una misma sub-estaci&oacute;n, en el mismo instante del d&iacute;a e igual estaci&oacute;n no presentan mayores variaciones entre s&iacute;. </p>     <p>Adicionalmente, se presenta en (Ma, Zheng, Tang, &amp; Dong, 2009) la validaci&oacute;n del modelo compuesto (ZIP + motor de inducci&oacute;n de tercer orden) obtenido mediante mediciones de campo, en donde los autores concluyen que el tama&ntilde;o de la perturbaci&oacute;n incide en gran manera en la validez del modelo de carga para determinados an&aacute;lisis. Se emplea un algoritmo de identificaci&oacute;n multi-curva para minimizar los efectos del ruido sobre los resultados. </p>     <p>A la fecha, se han publicado muchos art&iacute;culos sobre modelado de carga compuesta; sin embargo, casi todos se fundamentan en ecuaciones de carga cuyos par&aacute;metros pueden ser estimados mediante ajuste de curvas, como ya se mencion&oacute;. Debido a la complejidad asociada con las actuales cargas electr&oacute;nicas, en las cuales existe una relaci&oacute;n no lineal entre la potencia con la tensi&oacute;n y la frecuencia, en (Keyhani, Lu, &amp; Heydt, 2004) se propone un modelo compuesto de carga basado en redes neuronales recurrentes. Para lograr la adecuada representaci&oacute;n del comportamiento de las cargas empleando redes neuronales, es preciso disponer de una base de datos extensa, y por esta raz&oacute;n los autores entrenan con datos de simulaci&oacute;n, que se complementan posteriormente con mediciones en l&iacute;nea. </p>     <p>Una de las conclusiones relevantes acerca de la aplicaci&oacute;n de las redes neuronales artificiales (RNA) sobre el modelado de cargas se encuentra en (Li, Wang, &amp; Li, 2008), donde los autores se&ntilde;alan que no son adecuadas para describir las caracter&iacute;sticas din&aacute;micas del modelo de carga compuesto, debido a las caracter&iacute;sticas del algoritmo y a la estructura de la red. Por esto, los autores proponen un modelo de carga compuesto basado en la red artificial <I>Elman</I> con una estructura interna de realimentaci&oacute;n. </p>     ]]></body>
<body><![CDATA[<p>Como ya se mencion&oacute;, una de las limitaciones que presenta el enfoque basado en mediciones es el esfuerzo computacional requerido en la estimaci&oacute;n de modelos de carga que contengan una gran cantidad de par&aacute;metros, considerando adem&aacute;s el tama&ntilde;o actual de los sistemas de potencia y el n&uacute;mero de cargas. El n&uacute;mero de par&aacute;metros por determinar tiene un impacto significativo en la precisi&oacute;n de la metodolog&iacute;a de estimaci&oacute;n. Para resolver este problema, se han aplicado t&eacute;cnicas basadas en sensibilidad para determinar cu&aacute;les par&aacute;metros del modelo permanecen invariantes ante diversas perturbaciones, lo que permite reducir el n&uacute;mero total de par&aacute;metros por identificar, mejorando la velocidad y precisi&oacute;n en la estimaci&oacute;n como en (Xu, Si, &amp; Qian, 2011) y (Ju, Qin, Wu, Xie, &amp; Ning, 2011). En (Chen, Ju, Shao, &amp; Wu, 2007) se propone la identificaci&oacute;n de los par&aacute;metros de un modelo compuesto que comprende la red de distribuci&oacute;n y la potencia de carga. Los autores concluyen que la constante de inercia tiene poco efecto sobre la estimaci&oacute;n de los otros par&aacute;metros clave, en comparaci&oacute;n con la reactancia de la red de distribuci&oacute;n. En (Ju, y otros, 2007), los autores basados en an&aacute;lisis de sensibilidad del modelo de carga compuesto concluyen que los par&aacute;metros tales como porcentaje del motor en la carga total, reactancia de dispersi&oacute;n del estator y el deslizamiento inicial del rotor juegan un papel importante tanto en la din&aacute;mica del modelo como en la del sistema de potencia y, por tanto, es necesario estimarlos. En cambio, otros par&aacute;metros asociados al circuito del rotor o a la caracter&iacute;stica mec&aacute;nica de la carga pueden considerarse constantes, debido a su poca influencia sobre la din&aacute;mica del motor, como se concluye en (Chen, y otros, 2010). Como una alternativa al esfuerzo computacional que representa la estimaci&oacute;n de par&aacute;metros de un modelo de carga no lineal, en (Li, Xie, Yan, &amp; Han, 2007)  se propone la utilizaci&oacute;n del modelo Volterra y de patrones de clasificaci&oacute;n, para realizar una r&aacute;pida identificaci&oacute;n en l&iacute;nea de los par&aacute;metros dominantes de un modelo de carga compuesto. En el a&ntilde;o 2008, mediante mediciones de campo (Ma, Han, He, Dong, &amp; Hill, 2008), demuestra c&oacute;mo reducir el n&uacute;mero de par&aacute;metros a estimar para mejorar la eficiencia del modelo de carga, empleando el m&eacute;todo de la perturbaci&oacute;n para determinar las trayectorias de sensibilidad de los par&aacute;metros del motor equivalente. Un enfoque alternativo para la reducci&oacute;n de esfuerzo computacional se propone en (Guoping, Jun, &amp; Xiangsheng, 2011), a partir de m&eacute;todos de agrupamiento como el algoritmo <I>C means</I> difuso, para la clasificaci&oacute;n de barras e identificaci&oacute;n de modelos de carga. Como referencia reciente, en (Son, y otros, 2014), los autores determinan cu&aacute;les par&aacute;metros del modelo de carga compuesto pueden ser ajustados en valores fijos, mediante un an&aacute;lisis de sensibilidad basado en las matrices Hessianas necesarias para aplicar el m&eacute;todo de Levenberg&mdash;Marquardt. </p>      <p>En el &aacute;rea de las microredes, en (Diaz, Gonz&aacute;lez, G&oacute;mez, &amp; Diez, 2010), se analiza la influencia del modelo de carga compuesto en el comportamiento oscilatorio de las mismas; adicionalmente, se comparan los resultados con los obtenidos al considerar solo modelos de carga est&aacute;ticos. Una de las conclusiones obtenidas en este art&iacute;culo resalta la reducci&oacute;n que se presenta en el margen de cargabilidad de la microred al incluir motores de inducci&oacute;n en el modelo de carga. </p>     <p>Con la creciente penetraci&oacute;n de energ&iacute;as renovables, la estructura de las redes de distribuci&oacute;n se hace m&aacute;s din&aacute;mica y esto puede representar una mayor complejidad en el an&aacute;lisis de sistemas de gran dimensi&oacute;n. Como una alternativa a esto, en (Zali &amp; Milanovic, 2013) se propone un modelo equivalente din&aacute;mico de estas redes, que presente caracter&iacute;sticas similares al sistema original y permita reducir el tama&ntilde;o de las redes actuales para el caso de estudios espec&iacute;ficos. La estructura del modelo equivalente din&aacute;mico seleccionada es un conjunto generador-convertidor (para representar microturbinas o turbinas e&oacute;licas) en paralelo con un modelo de carga compuesto. </p>     <p>Por otra parte, la aplicaci&oacute;n de algoritmos evolutivos no ha sido ajena a la obtenci&oacute;n de los modelos de carga compuestos, debido a que han demostrado ser una herramienta &uacute;til para dar soluci&oacute;n a problemas de optimizaci&oacute;n en otras &aacute;reas (McDonnell, Reynolds, &amp; Fogel, 1995) (Yu &amp; Gen, 2010) (Lee, Gonzales, Periaux, &amp; Srinivas, 2011). Espec&iacute;ficamente, para el modelado de carga compuesto se encuentran las siguientes referencias: </p>     <p>En (Ma, He, &amp; Hill, 2006) se emple&oacute; una metodolog&iacute;a h&iacute;brida entre algoritmos gen&eacute;ticos (AG) y el m&eacute;todo de b&uacute;squeda Simplex, para determinar un conjunto &oacute;ptimo de par&aacute;metros del modelo compuesto. Inicialmente, con el AG se obtienen unos valores &oacute;ptimos de los par&aacute;metros iniciales y posteriormente se emplea el m&eacute;todo de b&uacute;squeda Simplex para construir el modelo. En (Ma, He, &amp; Hill, 2007) se utilizan los AG para estimar trece par&aacute;metros de un modelo de carga compuesto basado en mediciones, el cual fue comparado despu&eacute;s con un modelo obtenido con el m&eacute;todo de m&iacute;nimos cuadrados no lineales. Con mediciones en el sistema de transmisi&oacute;n, se presenta en (Zhang &amp; Bai, 2008) la obtenci&oacute;n de modelos de carga compuestos. Como el problema de estimaci&oacute;n de par&aacute;metros para este caso es no lineal, se emplea un m&eacute;todo con algoritmos gen&eacute;ticos, en el cual se mejora la direcci&oacute;n de b&uacute;squeda &oacute;ptima, la forma de mantener a los mejores individuos y una estrategia de emigraci&oacute;n que permite evitar la convergencia a soluciones locales. Se comparan los resultados obtenidos respecto a los entregados con el m&eacute;todo de Levenberg-Marquardt (LM). Los autores concluyen que se debe ser prudente con la propuesta realizada, ya que aunque los resultados num&eacute;ricos entregados por el algoritmo gen&eacute;tico son una buena aproximaci&oacute;n, este requiere m&aacute;s tiempo computacional que el algoritmo LM. Para redes el&eacute;ctricas a gran escala, se muestra en (Han, Ma, He, &amp; Dong, 2009) el desarrollo de un modelo de carga basado en mediciones de campo. Inicialmente se hace una clasificaci&oacute;n de los nodos para determinar la  ubicaci&oacute;n adecuada de los dispositivos de medici&oacute;n. Despu&eacute;s se estiman los par&aacute;metros de un modelo ZIP en paralelo con un motor de inducci&oacute;n, empleando un h&iacute;brido entre AG y m&eacute;todo de b&uacute;squeda Simplex. El algoritmo gen&eacute;tico se aplica inicialmente para determinar las regiones en las que se puede encontrar el &oacute;ptimo (definido como el conjunto de par&aacute;metros) y posteriormente se emplea el m&eacute;todo de b&uacute;squeda Simplex para determinar su valor. En (Choi, Chiang, &amp; Yu, 2009) se muestra la estimaci&oacute;n de los par&aacute;metros de un modelo de carga compuesto, mediante optimizaci&oacute;n basada en <I>Trust-Tech</I>. La estimaci&oacute;n de par&aacute;metros se plantea como un problema de optimizaci&oacute;n no lineal con restricciones. Los autores concluyen que la metodolog&iacute;a se puede aplicar exitosamente en la estimaci&oacute;n de par&aacute;metros del modelo compuesto planteado, ya que la t&eacute;cnica permite obtener m&uacute;ltiples m&iacute;nimos locales, de los cuales se puede determinar el valor &oacute;ptimo. Los autores en (Choi &amp; Chiang, 2009) proponen como alternativas al problema de m&uacute;ltiples soluciones que se pueden presentar, reducir el n&uacute;mero de par&aacute;metros del modelo de carga (ZIP o exponenciales), mediante la formulaci&oacute;n de un problema de programaci&oacute;n cuadr&aacute;tica con restricciones lineales, m&aacute;s que como m&iacute;nimos cuadrados no lineales. En (Wang, Han, &amp; Ma, 2010) se hace un an&aacute;lisis de sensibilidad sobre los par&aacute;metros; aquellos m&aacute;s sensibles son identificados utilizando AG y los menos sensibles son ajustados a valores fijos. </p>      <p>Adem&aacute;s de la aplicaci&oacute;n de AG, se encuentran t&eacute;cnicas nuevas como el <I>Harmony Search Algorithm </I>que est&aacute;n siendo adaptadas para su aplicaci&oacute;n al modelado de carga compuesta en redes de distribuci&oacute;n (Alinejad, Akbari, &amp; Kazemi, 2012). Por otra parte, debido a la disponibilidad de mediciones sincronizadas, se proponen nuevos enfoques en (Najafabadi &amp; Alouani, 2012), para el desarrollo de modelos a partir de la estimaci&oacute;n en l&iacute;nea, para suplir los problemas de la estimaci&oacute;n convencional fuera de l&iacute;nea (requerimientos de esfuerzo computacional y memoria). </p>     <p>Como una aplicaci&oacute;n de PSO (Particle Swarm Optimization) en la obtenci&oacute;n de modelos de carga compuestos, se encuentra (Rodriguez, Perez, &amp; Mora, 2013), en donde se propuso una modificaci&oacute;n al algoritmo original, consiguiendo mejorar las soluciones obtenidas por este. El algoritmo genera una poblaci&oacute;n inicial, la cual se desplaza a trav&eacute;s del espacio de soluciones a partir de la informaci&oacute;n de las mejores soluciones encontradas por cada part&iacute;cula y por el enjambre en su conjunto. Una dificultad del algoritmo PSO original es que las velocidades de desplazamiento de las part&iacute;culas en el espacio de soluciones decrecen a medida que avanza el proceso iterativo; en este escenario, el algoritmo se enfoca en una b&uacute;squeda local; sin embargo, se limita para encontrar soluciones en regiones no exploradas. Por tanto, se implementa un mecanismo denominado <I>reinicio de velocidad, </I>que permite generar un conjunto nuevo de velocidades cuando estas son menores a una tolerancia, lo que finalmente ayuda al algoritmo a determinar posibles soluciones &oacute;ptimas en otras regiones del espacio de soluciones. </p>     <p>Como referencias actuales se encuentra (Aree, 2014), en donde se presenta una metodolog&iacute;a para incorporar las caracter&iacute;sticas no lineales de las cargas reales en el an&aacute;lisis de flujo de carga, mediante modelos compuestos. En contraste con el c&aacute;lculo convencional de flujos de carga, en esta propuesta se obtienen mejores resultados debido al reajuste en forma separada de las potencias activa y reactiva de cada motor y carga est&aacute;tica, ante variaciones de tensi&oacute;n durante el proceso iterativo. </p>     <p>Por &uacute;ltimo, se aprecia en la revisi&oacute;n de la literatura un reciente inter&eacute;s por considerar el efecto de los motores de inducci&oacute;n en la estabilidad a corto plazo, debido a su r&aacute;pida tendencia de restauraci&oacute;n de potencia consumida ante un evento. Es as&iacute; como en (Xu, y otros, 2014) se propone una metodolog&iacute;a para determinar la ubicaci&oacute;n &oacute;ptima de compensaci&oacute;n din&aacute;mica de reactivos, considerando cargas compuestas. </p>      <p><B>APLICACI&Oacute;N DE MODELADO DE CARGA COMPUESTA BASADO EN MEDICIONES </b></p>     ]]></body>
<body><![CDATA[<p><b>Desarrollo de un modelo de carga compuesto a partir de mediciones </b></p>      <p>Con el fin de validar la respuesta del modelo de carga compuesto, ampliamente analizada en la revisi&oacute;n bibliogr&aacute;fica de este art&iacute;culo, en esta secci&oacute;n se presentan los resultados del modelo estimado, al utilizar los datos obtenidos de las simulaciones realizadas sobre el sistema IEEE de 30 barras (University of Washington, 1999). Con el fin de simular un efecto din&aacute;mico en la respuesta de la carga, el sistema IEEE de 30 barras se modifica mediante la inclusi&oacute;n de motores de inducci&oacute;n (con torque mec&aacute;nico constante), en la barra 29 del sistema. Los par&aacute;metros del modelo de carga se estiman empleando el algoritmo mejorado de optimizaci&oacute;n por enjambre de part&iacute;culas (PSO) presentado en (Rodriguez, Perez, &amp; Mora, 2013) y explicado en la secci&oacute;n anterior. Para estimar los par&aacute;metros del modelo se utiliza la informaci&oacute;n de la magnitud y el &aacute;ngulo de tensi&oacute;n, potencia activa y reactiva en la barra de carga, obtenidos en el caso de una falla trif&aacute;sica de 200 ms en la l&iacute;nea que conecta las barras 25 y 27. Se considera la presencia de ruido en las mediciones, con el fin de representar condiciones cercanas a las reales en los equipos de medici&oacute;n. La se&ntilde;al de ruido que se agrega es una se&ntilde;al aleatoria, generada mediante una distribuci&oacute;n normal, la cual tiene media cero y desviaci&oacute;n est&aacute;ndar de 0,005. </p>      <p>Los resultados de la estimaci&oacute;n y su comparaci&oacute;n con las mediciones de la respuesta de la carga se muestran en la <a href="#f3">figura 3</a>. Para cuantificar el error en la estimaci&oacute;n se emplea la <a href="#ec8">ecuaci&oacute;n (8)</a>. </p>     <p align="center"><a name="ec8"></a><img src="img/revistas/tecn/v19n44/v19n44a14ec8.jpg"></p>     <p align="center"><a name="f3"></a><img src="img/revistas/tecn/v19n44/v19n44a14f3.jpg"></p>      <p>Donde <I>N</I> es el n&uacute;mero de muestras de la ventana de tiempo a analizar, <img src="img/revistas/tecn/v19n44/v19n44a14img1.jpg"> corresponde a la medici&oacute;n en el instante <img src="img/revistas/tecn/v19n44/v19n44a14img2.jpg"> corresponde a la estimaci&oacute;n del modelo de carga en el instante <I>k</I><I>. </I>Este indicador se calcula de manera independiente para la potencia activa y reactiva. </p>      <p>Los resultados de la estimaci&oacute;n muestran que la respuesta del modelo de carga compuesto se ajusta de manera satisfactoria a los datos adquiridos del sistema de potencia, y la presencia de ruido en estos no presenta efectos considerables en la respuesta del modelo de carga. En la <a href="#t1">tabla 1</a> se presenta el conjunto de par&aacute;metros que se obtienen al final del proceso de optimizaci&oacute;n. </p>     <p align="center"><a name="t1"></a><img src="img/revistas/tecn/v19n44/v19n44a14t1.jpg"></p>      <p>Para mostrar la importancia de la utilizaci&oacute;n de modelos din&aacute;micos de carga, se propone a modo de comparaci&oacute;n la estimaci&oacute;n de un modelo de carga est&aacute;tico del tipo ZIP para emular la respuesta de la carga en la barra 29. Los resultados de la estimaci&oacute;n se muestran en la <a href="#f4">figura 4</a> y el conjunto de par&aacute;metros obtenidos, en la <a href="#t2">tabla 2</a>. </p>     <p align="center"><a name="f4"></a><img src="img/revistas/tecn/v19n44/v19n44a14f4.jpg"></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="t2"></a><img src="img/revistas/tecn/v19n44/v19n44a14t2.jpg"></p>      <p>A diferencia del modelo de carga compuesta, el desempe&ntilde;o del modelo ZIP es deficiente para reproducir el comportamiento din&aacute;mico de la carga, espec&iacute;ficamente en su parte transitoria, ya que la respuesta del modelo depende &uacute;nicamente de la tensi&oacute;n instant&aacute;nea del modelo de carga y no tiene en cuenta otros tipos de variables din&aacute;micas que caracterizan las cargas. La <a href="#t3">tabla 3</a> presenta un comparativo del desempe&ntilde;o del modelo compuesto y el modelo ZIP empleando en la <a href="#ec8">ecuaci&oacute;n (8)</a>. </p>     <p align="center"><a name="t3"></a><img src="img/revistas/tecn/v19n44/v19n44a14t3.jpg"></p>      <p>El indicador de error demuestra el resultado visualizado en la <a href="#f4">figura 4</a>, en donde los errores en el modelo ZIP se duplican en comparaci&oacute;n con el modelo compuesto, tanto para potencia activa como potencia reactiva. Esto confirma como ya se ha reportado en algunas referencias (Kundur, 1993), (Choi B.-K. , y otros, 2006), que la utilizaci&oacute;n del modelo ZIP no es apropiado para representar respuestas din&aacute;micas significativas de la carga ante perturbaciones en el sistema. </p>      <p><b><B>Validaci&oacute;n de la capacidad de generalizaci&oacute;n del modelo compuesto </b></b></p>      <p>Una de las principales preguntas que se hacen al obtener un modelo de carga est&aacute; relacionada con su capacidad de generalizaci&oacute;n, es decir, si el modelo es v&aacute;lido para otras condiciones de operaci&oacute;n diferentes a las cuales fue ajustado. Para analizar esta caracter&iacute;stica del modelo de carga compuesto obtenido, se hace una prueba de validaci&oacute;n cruzada para comprobar la precisi&oacute;n del modelo. Se obtienen mediante simulaci&oacute;n datos de la respuesta de la carga de la barra 29 en magnitud de tensi&oacute;n, &aacute;ngulo de tensi&oacute;n, potencia activa y potencia reactiva, ante 4 diferentes perturbaciones (falla trif&aacute;sica, salida de transformador, p&eacute;rdida de excitaci&oacute;n de un generador y salida de l&iacute;nea). La prueba de validaci&oacute;n cruzada se desarroll&oacute; de la siguiente manera. </p>      <p>Inicialmente se obtiene el modelo de carga utilizando el conjunto de datos de la primera perturbaci&oacute;n. Una vez desarrollado el modelo, se valida su respuesta con los datos de las dem&aacute;s perturbaciones, obteniendo para cada caso un error de validaci&oacute;n. El procedimiento se repite desarrollando el modelo con el siguiente conjunto de datos y luego validando su respuesta con los conjuntos de datos restantes. La <a href="#t4">tabla 4</a> resume los errores obtenidos durante el desarrollo de los modelos de carga con cada uno de los conjuntos de datos de perturbaciones. </p>     <p align="center"><a name="t4"></a><img src="img/revistas/tecn/v19n44/v19n44a14t4.jpg"></p>     <p>En la <a href="#t4">tabla 4</a>, los datos 1 y 3 corresponden a perturbaciones severas (falla trif&aacute;sica y p&eacute;rdida de excitaci&oacute;n), mientras que los datos 2 y 4 corresponden a perturbaciones leves (salida de transformador y salida de l&iacute;nea). El ajuste del modelo es mejor cuando los efectos transitorios son suaves, como es el caso de las perturbaciones peque&ntilde;as; sin embargo, errores bajos no garantizan que el modelo responda satisfactoriamente ante diversas condiciones de operaci&oacute;n, esto es, no garantiza su capacidad de generalizaci&oacute;n. En las <a href="#t5">tablas 5</a> y <a href="#t6">6</a> se presentan los errores de validaci&oacute;n cruzada para cada conjunto de datos de entrenamiento. Las filas representan los datos empleados para la obtenci&oacute;n del modelo, y las columnas representan el error de validaci&oacute;n del modelo con los otros conjuntos de datos. </p>     <p align="center"><a name="t5"></a><img src="img/revistas/tecn/v19n44/v19n44a14t5.jpg"></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="t6"></a><img src="img/revistas/tecn/v19n44/v19n44a14t6.jpg"></p>     <p>De las <a href="#t5">tablas 5</a> y <a href="#t6">6</a>, se observa que los errores en los modelos obtenidos con datos de perturbaci&oacute;n severa (modelos 1 y 3), cuando se validan con datos de perturbaci&oacute;n leve (datos 2 y 4) son menores en comparaci&oacute;n con la situaci&oacute;n contraria, en donde los modelos desarrollados con datos de perturbaci&oacute;n leve (modelos 2 y 4) se validan con datos de perturbaci&oacute;n severa (datos 1 y 2). Esta afirmaci&oacute;n se puede corroborar cualitativamente con los siguientes casos puntuales de las pruebas de validaci&oacute;n. Inicialmente, se ilustra el caso de la validaci&oacute;n con los datos de perturbaci&oacute;n leve (conjunto de datos 4), cuando el modelo se obtiene con los datos de perturbaci&oacute;n severa (conjunto de datos 1). La <a href="#f5">figura 5</a> muestra la respuesta en potencias activa y reactiva cuando se efect&uacute;a la salida de la l&iacute;nea 27-30; adem&aacute;s se presenta la respuesta del modelo de carga. Tambi&eacute;n se observa en este caso que la respuesta se ajusta de manera adecuada a los datos y la respuesta se aproxima al comportamiento transitorio de la carga. </p>     <p align="center"><a name="f5"></a><img src="img/revistas/tecn/v19n44/v19n44a14f5.jpg"></p>     <p align="center"><a name="f6"></a><img src="img/revistas/tecn/v19n44/v19n44a14f6.jpg"></p>      <p>Sin embargo, es importante analizar la situaci&oacute;n contraria. Ahora se muestra el caso de la prueba de validaci&oacute;n con una perturbaci&oacute;n severa (conjunto de datos 3), cuando el modelo se obtiene con datos de una perturbaci&oacute;n leve (conjunto de datos 4). La figura 6 presenta la respuesta del modelo de carga y del sistema, cuando se pierde la excitaci&oacute;n del generador s&iacute;ncrono. En este caso, la perturbaci&oacute;n es severa considerando la magnitud de la desviaci&oacute;n en las potencias. </p>     <p>De acuerdo con las figuras anteriores, as&iacute; como con los resultados de las <a href="#t5">tablas 5</a> y <a href="#t6">6</a>, es evidente que existen errores considerables entre los datos adquiridas del sistema con la respuesta del modelo de la carga. Debido a que el entrenamiento se hace con datos de una perturbaci&oacute;n leve, el modelo de carga no captura el comportamiento din&aacute;mico que presenta la carga cuando las variaciones de tensi&oacute;n son severas. Por tanto, la validaci&oacute;n presenta errores superiores en comparaci&oacute;n con el caso anterior. A partir de la prueba de validaci&oacute;n, se destaca la importancia de la utilizaci&oacute;n de datos adecuados de la respuesta real de la carga en el sistema de potencia, con el fin de que el modelo represente mejor su comportamiento. Las mediciones por emplear dependen tambi&eacute;n de la estructura del modelo de carga, aunque en el caso del modelo compuesto es deseable utilizar mediciones de perturbaciones en donde las variaciones de tensi&oacute;n sean superiores a 20% de la tensi&oacute;n nominal, de acuerdo con los resultados presentados en la <a href="#t4">tabla 4</a>. </p>     <p><font size="3"><B>Conclusiones</B></font></p>     <p>En este documento se presenta una recopilaci&oacute;n de algunas de las metodolog&iacute;as utilizadas para la obtenci&oacute;n de modelos de carga compuestos, con el fin de facilitar el an&aacute;lisis de las tendencias en cuanto a enfoques y nuevas propuestas en la tem&aacute;tica de estudio. Esta &aacute;rea de investigaci&oacute;n, aunque ha sido tratada hace m&aacute;s de tres d&eacute;cadas, contin&uacute;a vigente debido a que involucra caracter&iacute;sticas din&aacute;micas y complejas del sistema de potencia y de su creciente necesidad de mejor representaci&oacute;n de fen&oacute;menos f&iacute;sicos. </p>      <p>Como aporte adicional, se present&oacute; un modelo compuesto basado en mediciones (datos obtenidos bajo simulaci&oacute;n), que permite reproducir satisfactoriamente la respuesta de una carga din&aacute;mica ante una perturbaci&oacute;n, comparativamente con un modelo est&aacute;tico. Posteriormente, se comprueba que la capacidad de generalizaci&oacute;n del modelo compuesto obtenido depende del tipo y magnitud de la perturbaci&oacute;n que fue empleado para la estimaci&oacute;n. Cuanto mayor sea la variaci&oacute;n de tensi&oacute;n empleada en la estimaci&oacute;n, el modelo presentar&aacute; m&aacute;s posibilidades de representar las caracter&iacute;sticas de la carga bajo otras variaciones. Esta conclusi&oacute;n obliga a considerar una limitaci&oacute;n que presentan los modelos de carga compuestos, que emplean las mediciones obtenidas en condiciones operativas normales y, por tanto, es preciso disponer de herramientas de monitorizaci&oacute;n permanente en el sistema para lograr capturar respuestas transitorias de mayor magnitud. Esto puede conseguirse mediante la utilizaci&oacute;n masiva de la informaci&oacute;n suministrada por los sistemas de monitorizaci&oacute;n de &aacute;rea amplia en los sistemas de potencia. </p>  <hr>     <p><b><font size="3">Referencias</font></b></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Abdelaziz, A.; Badr, M., &amp; Younes, A. (Nov. 2007). Dynamic load modeling of an Egyptian primary distribution system using neural networks. <I>International </I><I>Journal of Electrical Power &amp; Energy Systems, 29</I>(9), 637-649.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0123-921X201500020001400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Abul'Wafa, A. (2012). A network-topology-based load flow for radial distribution networks with compo site and exponential load. <I>Electric Power Systems Research, 91</I>, 37-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0123-921X201500020001400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Alinejad, B.; Akbari, M., &amp; Kazemi, H. (2012). PMU-based distribution network load modelling using Harmony Search Algorithm. <I>Proceedings of 17th Conference on Electrical Power Distribution Networks</I>, pp. 1-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0123-921X201500020001400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Aree, P. (2014). Power Flow Computation Considering Nonlinear Characteristics of Composite Load Model. <I>Proceedings of the International Electrical Engineering Congress (iEECON)</I>, pp. 1-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0123-921X201500020001400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Chen, D., &amp; Mohler, R. (July 2003). Neural-Network-Based Load Modeling and its Use in Voltage Stability Analysis. <I>IEEE Transactions on Control Systems Technology, 11</I>(11), 460-470.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0123-921X201500020001400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Chen, Q.; Ju, P.; Shao, Z.-Y., &amp; Wu, F. (2007). Electrical Load Modeling with Considering Distribution Network. <I>Proceedings of 2007 iREP Symposium Bulk Power System Dynamics and Control</I>, pp. 1-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0123-921X201500020001400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Chen, Q.; Ju, P.; Shi, K.; Tang, Y.; Shao, Z., &amp; Yang, W. (2010). Parameter estimation and comparison of the load models with considering distribution network directly and indirectly. <I>International Journal of Electrical Power and Energy Systems, 32</I>(9), 965-968.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0123-921X201500020001400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Choi, B., &amp; Chiang, H. (May 2009). Multiple Solutions and Plateau Phenomenon in Measurement-Based Load Model Development: Issues and Suggestions. <I>IEEE Transactions on Power Systems, 24</I>(2), 824-831.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0123-921X201500020001400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Choi, B.; Chiang, H., &amp; Yu, D. (2009). Trust-Tech based Parameter Estimation and its Application to Power System Load Modeling. <I>Proceedings of IEEE PES General Meeting.</I> Calgary.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0123-921X201500020001400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Choi, B.; Chiang, H.; Li, Y.; Li, H.; Chen, Y.; Huang, D., &amp; Lauby, M. (Aug. 2006). Measurement-based Dynamic Load Models: Derivation, Comparison and Validation. <I>IEEE Transactions on Power Systems, 21</I>(3), 1276-1283.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0123-921X201500020001400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Choi, B.-K.; Chiang, H.-D.; Li, Y.; Chen, Y.-T.; Huang, D.-H., &amp; Lauby, M. (2006). Development of Composite Load Models of Power Systems using On-line Measurement Data. <I>Proceedings of IEEE PES General Meeting.</I> Montreal.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S0123-921X201500020001400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>De Tuglie, E.; Patrono, G., &amp; Torelli, F. (2005). A sensitivity-based approach for static and dynamic load parameter estimation. <I>Proceedings of IEEE Russia Power Tech.</I> St. Petersburg.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000135&pid=S0123-921X201500020001400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>Department of Energy and Climate Change (DECC). (2010). <I>Energy Trends: Electricity and Electricity Consumption in the UK.</I> National Statistics Publications.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000137&pid=S0123-921X201500020001400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Diaz, G.; Gonz&aacute;lez, C.; G&oacute;mez, J., &amp; Diez, A. (2010). Composite Loads in Stand-Aline Inverter-Based Mi-crogrids-Modeling Procedure and Effects on Load Margin. <I>IEEE Transactions on Power Systems, 25</I>(2), 894-905.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S0123-921X201500020001400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>General Electric Company (1987). <I>EPRI Final Report EL5003: Load modeling for powerflow and transient stability computer studies.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000141&pid=S0123-921X201500020001400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </I></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Guoping, S.; Jun, L., &amp; Xiangsheng, L. (2011). Load clustering and synthetic modeling based on an improved fuzzy C means clustering algorithm. <I>Proceedings of 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies</I>, pp. 859-865. Shandong.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000143&pid=S0123-921X201500020001400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Han, D.; Ma, J.; He, R.-M., &amp; Dong, Z.-Y. (2009). A Real Application of Measurement-Based Load Modeling in Large Scale Power Grids and Its Validation. <I>IEEE Transitions on Power Systems, 24</I>(4), 1756-1764.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000145&pid=S0123-921X201500020001400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>He, R.-M.; Ma, J., &amp; Hill, D. (May 2006). Composite Load Modeling via Measurement Approach. <I>IEEE Transactions on Power Systems, 21</I>(2), 663-672.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000147&pid=S0123-921X201500020001400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>IEEE Task Force on Load Representation for Dynamic Performances. (May 1993). Load representation for dynamic perfomance analysis. <I>IEEE Transactions on Power Systems, 8</I>(2), 472-482.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000149&pid=S0123-921X201500020001400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>IEEE Task Force on Load Representation for Dynamic Performances. (Feb. 1995a). Bibliography on load models for power flow and dynamic perfomance simulation. <I>IEEE Transactions on Power Systems, 10</I>(1), 523-538.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000151&pid=S0123-921X201500020001400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>IEEE Task Force on Load Representation for Dynamic Performances. (Aug. 1995b). Standard Load Models for Power Flow and Dynamic Performance Simulation. <I>IEEE Transactions on Power Systems</I>, 1302-1313.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000153&pid=S0123-921X201500020001400021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ju, P.; Qin, C.; Wu, F.; Xie, H., &amp; Ning, Y. (2011). Load modeling for wide area power system. <I>Electrical Power and Energy Systems, 33</I>, 909-917.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000155&pid=S0123-921X201500020001400022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ju, P.; Wu, F.; Shao, Z.-Y.; Zhang, X.-P.; Fu, H.-J.; Zhang, P.-F.; . . . Han, J.-D. (Sept. 2007). Composite load models based on field measurements and their applications in dynamic analysis. <I>IET Generation, Transmission and Distribution, 1</I>(5), 724-730.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000157&pid=S0123-921X201500020001400023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Kalesar, B., &amp; Seifi, A. (2010). Fuzzy load flow in balanced and unbalanced radial distribution systems incorporating composite load model. <I>Electrical Power and Energy Systems</I>, 17-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000159&pid=S0123-921X201500020001400024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Kao, W. (Aug. 2001). The Effect of Load Models on Unstable Low-Frequency Oscillation Damping in Taipower System Experience w/wo Power System Stabilizers. <I>IEEE Transactions on Power Systems, 16</I>(3), 463-472.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000161&pid=S0123-921X201500020001400025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Keyhani, A.; Lu, W., &amp; Heydt, G. (2004). Composite Neural Netwrok Load Models for Power System Stability Analysis. <I>Proceedings of IEEE Power Systems Conference &amp; Exposition</I>, pp. 1159-1163.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000163&pid=S0123-921X201500020001400026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Knyazkin, V.; Ca&ntilde;izares, C., &amp; S&ouml;der, L. (May 2004). On the Parameter Estimation and Modeling of Aggregate Power System Loads. <I>IEEE Transactions on Power Systems, 19</I>(2), 1023-1031.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000165&pid=S0123-921X201500020001400027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Kosterev, D., &amp; Meklin, A. (2006). Load Modeling in WECC. <I>Proceedings of Power Systems Conference and Exposition PSCE</I>, pp. 576-581.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000167&pid=S0123-921X201500020001400028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Kosterev, D.; Meklin, A.; Undrill, J.; Lesieutre, B.; Price, W.; Chassin, D., . . . Yang, S. (2008). Load Modeling in Power System Studies: WECC Progress Update. <I>Proceedings of PES General Meeting</I>, pp. 1-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000169&pid=S0123-921X201500020001400029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Kosterev, D.; Taylor, C., &amp; Mittelstadt, W. (Aug. 1999). Model validation for the August 10, 1996 WSCC system outage. <I>IEEE Transactions on Power Systems, 14</I>(3), 967-979.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000171&pid=S0123-921X201500020001400030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Kundur, P. (1993). <I>Power System Stability and Control. </I>New York: McGraw-Hill.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000173&pid=S0123-921X201500020001400031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Lee, D.; Gonzales, L.; Periaux, J., &amp; Srinivas, K. (Apr. 2011). Efficient hybrid-game strategies coupled to evolutionary algorithms for robust multidisciplinary design optimization in aerospace engineering. <I>IEEE Transactions on Evolutionary Computation, 15</I>(2), 133-150.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000175&pid=S0123-921X201500020001400032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Li, L.; Xie, X.; Yan, J., &amp; Han, Y. (2007). Fast Online Identification of the Dominant Parameters of Composite Load Model Using Volterra Model and Pattern Classification. <I>Proceedings of IEEE PES General Meeting</I>, pp. 1-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000177&pid=S0123-921X201500020001400033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Li, X.; Wang, L., &amp; Li, P. (2008). The Study on Composite Load Model Structure of Artificial Neural Network. <I>Proceedings of 3rd International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. </I>NanJing. pp. 1564-1570.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000179&pid=S0123-921X201500020001400034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ma, J.; Han, D.; He, R.-M.; Dong, Z.-Y., &amp; Hill, D. (2008). Reducing Identified Parameters of Measurement-Based Composite Load Model. <I>IEEE Transactions on Power Systems, 23</I>(1), 76-83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000181&pid=S0123-921X201500020001400035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Ma, J.; He, R., &amp; Hill, D. (May 2006). Load Modeling by Finding Support Vectors of Load Data from Field Measurements. <I>IEEE Transactions on Power Systems, 21</I>(2), 726-735.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000183&pid=S0123-921X201500020001400036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ma, J.; He, R.-M., &amp; Hill, D. (2007). Measurement-based Load Modeling using Genetic Algorithms. <I>Proceedings of IEEE Congress on Evolutionary Computation</I>, pp. 2909-2916.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000185&pid=S0123-921X201500020001400037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ma, J.; Zheng, X.-Y.; Tang, Y.-H., &amp; Dong, Z.-Y. (2009). Validating Measurement-Based Composite Load Model. <I>Proceedings of 8th International Conference on Advances in Power System Control, Operation and Management</I>, pp. 1-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000187&pid=S0123-921X201500020001400038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Maitra, A.; Gaikwad, A.; Pourbeik, P., &amp; Brooks, D. (2008). Load Model Parameter Derivation Using an Automated Algorithm and Measured Data. <I>Proceedings of IEEE PES Conversion and Delivery of Electrical Energy in the 21st Century</I>, pp. 1-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000189&pid=S0123-921X201500020001400039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Mauricio, W., &amp; Semlyen, A. (Nov. 1972). Effect of load characteristics on the dynamic stability of power systems. <I>IEEE Transactions on Power Apparatus and Systems, 14</I>(3), 2295-2304.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000191&pid=S0123-921X201500020001400040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>McDonnell, J.; Reynolds, J., &amp; Fogel, D. (1995). <I>Special Session on Applications of evolutionary computation to biology and biochemistry.</I> MIT Press.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000193&pid=S0123-921X201500020001400041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Milanovic, J.; Yamashita, K.; Martinez, S.; Djokie, S., &amp; Korunovic, L. (Aug. 2013). International Industry Practice on Power System Load Modeling. <I>IEEE Transactions on Power Systems, 28</I>(3).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000195&pid=S0123-921X201500020001400042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Najafabadi, A., &amp; Alouani, A. (2012). Real time estimation of sensitive parameters of composite power system load model. <I>Proceedings of 2012 IEEE Power </I><I>and Energy Society Transmission and Distribution Conference and Exposition. </I>Orlando. pp. 1-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000197&pid=S0123-921X201500020001400043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Nozari, F.; Kankam, M., &amp; Price, W. (Nov. 1987). Aggregation of Induction Motors for Transient Stability Load Modeling. <I>IEEE Transactions on Power Systems, 2</I>(4), 1096-1103.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000199&pid=S0123-921X201500020001400044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Ornata, T., &amp; Uemura, K. (Nov. 1998). Aspects of Voltage Responses of Induction Loads. <I>IEEE Transactions on Power Systems, 13</I>(4), 1337-1344.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000201&pid=S0123-921X201500020001400045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Peng, W.; Yan-hong, W.; Guo-qiang, H., &amp; Rui, M. (2005). Study on the Reduction of Identified Parameters of the Power Load's Aggregated Motor Model with the AIm of Sustaining Its Representabilidad. <I>Proceedings of IEEE PES Transmission and Distribution Conference and Exhibition: Asia and Pacific.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000203&pid=S0123-921X201500020001400046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </I></p>     <!-- ref --><p>Pereira, L.; Kosterev, D.; Mackin, P.; Davies, D.; Undrill, J., &amp; Zhu, W. (Nov. 2002). An Interim Dynamic Induction Motor Model for Stability Studies in the WSCC. <I>IEEE Transactions on Power Systems, 17</I>(4), 1108-1115.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000205&pid=S0123-921X201500020001400047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Rifaat, R. (2004). On Composite Load Modeling for Voltage Stability and Under Voltage Load Shedding. <I>Proceedings of IEEE PES General Meeting</I>, pp. 1603-1610).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000207&pid=S0123-921X201500020001400048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Rodriguez, L.; Perez, S., &amp; Mora, J. (2013). Particle Swarm Optimization applied in Power System Measurement-Based Load Modeling. <I>Proceedings of IEEE Congress on Evolutionary Computation</I>, pp. 2368-2375. Canc&uacute;n.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000209&pid=S0123-921X201500020001400049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Shi, G.; Peng, G., &amp; Liu, X. (2012). Comparative Research on Power Load Modeling Method in Power Electrical System. <I>Proceedings of Fifth International Conference on Intelligent Computation Technology and Automation (ICICTA)</I>, pp. 455-458.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000211&pid=S0123-921X201500020001400050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Shi, J., &amp; He, R. (2003). Measurement-based load modeling-model structure. <I>Proceedings of IEEE Power-Tech Conference.</I> Bologna.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000213&pid=S0123-921X201500020001400051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Son, S.; Lee, S.; Choi, D.; Song, K.; Park, J.; Kwon, Y., . . . Park, J. (2014). Improvement of Composite Load Modeling Based on Parameter Sensitivity and Dependency Analyses. <I>IEEE Transactions on Power Systems</I>, 242-250.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000215&pid=S0123-921X201500020001400052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Song, J.; Cotilla-Sanchez, E., &amp; Brekken, T. (2013). Load Modeling Methodologies for Cascading Outage Simulation Considering Power System Stability. <I>1st IEEE Conference on Technologies for Sustainability (SusTech)</I>, pp. 78-85.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000217&pid=S0123-921X201500020001400053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>University of Washington. (1999). <I>Electrical Engineering</I>. Obtenido de <a href="http://www.ee.washington.edu/ research/pstca/" target="_blank">http://www.ee.washington.edu/ research/pstca/</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000219&pid=S0123-921X201500020001400054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Wang, J.; Han, M., &amp; Ma, J. (2010). A New Identification Strategy for Improving Convergence Stability of Load Model Parameters. <I>Proceedings of International Conference on Electrical and Control Engineering</I>, pp. 45-148.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000221&pid=S0123-921X201500020001400055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Wang, J.; Jiang, H.; Chang, C., &amp; Liu, A. (Feb. 1994). Development of a frequency-dependent composite load model using measurement approach. <I>IEEE Transactions on Power Systems, 9</I>(3), 1546-1556.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000223&pid=S0123-921X201500020001400056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Wang, J.; Li, X.; Su, S., &amp; Xia, X. (2006). Research on Dunamic Load Modeling Using Back Propagation Neural Network for Electric Power System. <I>Proceedings of International Conference on Power System Technology</I>, pp. 1-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000225&pid=S0123-921X201500020001400057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Wei-guo, W.; Ren-mu, H., &amp; Tie-Qiang, W. (2002). The induction motor model to reflect dynamic mechanism of synthetic load. <I>Automation of Electric Power Systems, 26</I>(4), 23-27.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000227&pid=S0123-921X201500020001400058&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Wen, J.; Jiang, L.; Wu, Q., &amp; Cheng, S. (2003). Power System Load Modeling by Learning Based on System Measurements. <I>IEEE Transactions on Power Delivery, 18</I>(2), 364-371.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000229&pid=S0123-921X201500020001400059&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Wu, Q.; Wen, J.; Nuttall, K.; Shimmin, D., &amp; Cheng,  S. (2003). Power System Load Modeling by Evolutionary Computation Based on System Measurements. <I>Electric Power Components and Systems, 31</I>(5), 423-439.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000231&pid=S0123-921X201500020001400060&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Xin-ran, L.; Ren-mu, H., &amp; Zhou, W. (1999). The General Induction Motor Model and its description ability for synthetic loads for electric power system. <I>Journal of North China Electric Power University, 26</I>(1).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000233&pid=S0123-921X201500020001400061&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Xu, Y.; Dong, Z.; Meng, K.; Yao, W.; Zhang, R., &amp; Wong, K. (2014). Multi-Objective Dynamic VAR Planning Against Short-Term Voltage Instability Using a Decomposition-Based Evolutionary Algorithm. <I>IEEE Transactions on Power Systems, 29</I>(6), 2813-2822.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000235&pid=S0123-921X201500020001400062&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Xu, Y.; Si, D., &amp; Qian, Y. (2011). Research on Feasibility of Composite Load Modeling Based on WAMS. <I>Proceedings of 2011 Asia-Pacific Power and Energy Engineering Conference</I>, pp. 1-4. Wuhan.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000237&pid=S0123-921X201500020001400063&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Yu, X., &amp; Gen, M. (2010). <I>Introduction to Evolutionary Algorithms (Decision Engineering).</I> London: Springer-Verlag.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000239&pid=S0123-921X201500020001400064&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>Zali, S., &amp; Milanovic, J. (2013). Generic Model of Active Distribution Network for Large Power System Stability Studies. <I>IEEE Transactions on Power Systems, 28</I>(3), 3126-3133.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000241&pid=S0123-921X201500020001400065&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     ]]></body>
<body><![CDATA[<!-- ref --><p>Zhang, P., &amp; Bai, H. (2008). Derivation of Load Model Parameters using Improved Genetic Algorithm. <I>Proceedings of International Conference on Electric Utility Deregulation and Restructuring and Power Technologies</I>, pp. 970-977.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000243&pid=S0123-921X201500020001400066&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>  </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abdelaziz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Badr]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Younes]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dynamic load modeling of an Egyptian primary distribution system using neural networks]]></article-title>
<source><![CDATA[International Journal of Electrical Power & Energy Systems]]></source>
<year>Nov.</year>
<month> 2</month>
<day>00</day>
<volume>29</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>637-649</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abul'Wafa]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A network-topology-based load flow for radial distribution networks with compo site and exponential load]]></article-title>
<source><![CDATA[Electric Power Systems Research]]></source>
<year>2012</year>
<volume>91</volume>
<page-range>37-43</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alinejad]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Akbari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kazemi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[PMU-based distribution network load modelling using Harmony Search Algorithm]]></source>
<year>2012</year>
<conf-name><![CDATA[ Proceedings of 17th Conference on Electrical Power Distribution Networks]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-6</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aree]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Power Flow Computation Considering Nonlinear Characteristics of Composite Load Model]]></source>
<year>2014</year>
<conf-name><![CDATA[ Proceedings of the International Electrical Engineering Congress (iEECON)]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-4</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mohler]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neural-Network-Based Load Modeling and its Use in Voltage Stability Analysis]]></article-title>
<source><![CDATA[IEEE Transactions on Control Systems Technology]]></source>
<year>July</year>
<month> 2</month>
<day>00</day>
<volume>11</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>460-470</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Ju]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Shao]]></surname>
<given-names><![CDATA[Z.-Y]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrical Load Modeling with Considering Distribution Network]]></source>
<year>2007</year>
<conf-name><![CDATA[ Proceedings of 2007 iREP Symposium Bulk Power System Dynamics and Control]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-6</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Ju]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Shao]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Parameter estimation and comparison of the load models with considering distribution network directly and indirectly]]></article-title>
<source><![CDATA[International Journal of Electrical Power and Energy Systems]]></source>
<year>2010</year>
<volume>32</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>965-968</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Chiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multiple Solutions and Plateau Phenomenon in Measurement-Based Load Model Development: Issues and Suggestions]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>May </year>
<month>20</month>
<day>09</day>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>824-831</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Chiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Trust-Tech based Parameter Estimation and its Application to Power System Load Modeling]]></source>
<year>2009</year>
<conf-name><![CDATA[ Proceedings of IEEE PES General Meeting]]></conf-name>
<conf-loc>Calgary </conf-loc>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Chiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Lauby]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurement-based Dynamic Load Models: Derivation, Comparison and Validation]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Aug.</year>
<month> 2</month>
<day>00</day>
<volume>21</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1276-1283</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Chiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Lauby]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Development of Composite Load Models of Power Systems using On-line Measurement Data]]></source>
<year>2006</year>
<conf-name><![CDATA[ Proceedings of IEEE PES General Meeting]]></conf-name>
<conf-loc>Montreal </conf-loc>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Tuglie]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Patrono]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Torelli]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[A sensitivity-based approach for static and dynamic load parameter estimation]]></source>
<year>2005</year>
<conf-name><![CDATA[ Proceedings of IEEE Russia Power Tech]]></conf-name>
<conf-loc>St. Petersburg </conf-loc>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="book">
<collab>Department of Energy and Climate Change (DECC)</collab>
<source><![CDATA[Energy Trends: Electricity and Electricity Consumption in the UK]]></source>
<year>2010</year>
<publisher-name><![CDATA[National Statistics Publications]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Diaz]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Diez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Composite Loads in Stand-Aline Inverter-Based Mi-crogrids-Modeling Procedure and Effects on Load Margin]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>2010</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>894-905</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<collab>General Electric Company</collab>
<source><![CDATA[EPRI Final Report EL5003: Load modeling for powerflow and transient stability computer studies]]></source>
<year>1987</year>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guoping]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Jun]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Xiangsheng]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Load clustering and synthetic modeling based on an improved fuzzy C means clustering algorithm]]></source>
<year>2011</year>
<conf-name><![CDATA[ Proceedings of 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies]]></conf-name>
<conf-loc> </conf-loc>
<page-range>859-865</page-range><publisher-loc><![CDATA[Shandong ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R.-M]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[Z.-Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Real Application of Measurement-Based Load Modeling in Large Scale Power Grids and Its Validation]]></article-title>
<source><![CDATA[IEEE Transitions on Power Systems]]></source>
<year>2009</year>
<volume>24</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1756-1764</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R.-M]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hill]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Composite Load Modeling via Measurement Approach]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>May </year>
<month>20</month>
<day>06</day>
<volume>21</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>663-672</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<collab>IEEE Task Force on Load Representation for Dynamic Performances</collab>
<article-title xml:lang="en"><![CDATA[Load representation for dynamic perfomance analysis]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>1993</year>
<volume>8</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>472-482</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<collab>IEEE Task Force on Load Representation for Dynamic Performances</collab>
<article-title xml:lang="en"><![CDATA[Bibliography on load models for power flow and dynamic perfomance sim]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Feb.</year>
<month> 1</month>
<day>99</day>
<volume>10</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>523-538</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<collab>IEEE Task Force on Load Representation for Dynamic Performances</collab>
<article-title xml:lang="en"><![CDATA[Standard Load Models for Power Flow and Dynamic Performance Simulation]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Aug.</year>
<month> 1</month>
<day>99</day>
<page-range>1302-1313</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ju]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Qin]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Xie]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ning]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Load modeling for wide area power system]]></article-title>
<source><![CDATA[Electrical Power and Energy Systems]]></source>
<year>2011</year>
<volume>33</volume>
<page-range>909-917</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ju]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Shao]]></surname>
<given-names><![CDATA[Z.-Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[X.-P]]></given-names>
</name>
<name>
<surname><![CDATA[Fu]]></surname>
<given-names><![CDATA[H.-J]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[P.-F]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[J.-D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Composite load models based on field measurements and their applications in dynamic analysis]]></article-title>
<source><![CDATA[IET Generation, Transmission and Distribution]]></source>
<year>Sept</year>
<month>. </month>
<day>20</day>
<volume>1</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>724-730</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kalesar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Seifi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fuzzy load flow in balanced and unbalanced radial distribution systems incorporating composite load model]]></article-title>
<source><![CDATA[Electrical Power and Energy Systems]]></source>
<year>2010</year>
<page-range>17-23</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kao]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Effect of Load Models on Unstable Low-Frequency Oscillation Damping in Taipower System Experience w/wo Power System Stabilizers]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Aug.</year>
<month> 2</month>
<day>00</day>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>463-472</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Keyhani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Heydt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Composite Neural Netwrok Load Models for Power System Stability Analysis]]></source>
<year>2004</year>
<conf-name><![CDATA[ Proceedings of IEEE Power Systems Conference & Exposition]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1159-1163</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Knyazkin]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Cañizares]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Söder]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the Parameter Estimation and Modeling of Aggregate Power System Loads]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>May </year>
<month>20</month>
<day>04</day>
<volume>19</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1023-1031</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kosterev]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Meklin]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Load Modeling in WECC]]></source>
<year>2006</year>
<conf-name><![CDATA[ Proceedings of Power Systems Conference and Exposition PSCE]]></conf-name>
<conf-loc> </conf-loc>
<page-range>576-581</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kosterev]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Meklin]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Undrill]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lesieutre]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Price]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Chassin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Load Modeling in Power System Studies: WECC Progress Update]]></source>
<year>2008</year>
<conf-name><![CDATA[ Proceedings of PES General Meeting]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kosterev]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Mittelstadt]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Model validation for the August 10, 1996 WSCC system outage]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Aug.</year>
<month> 1</month>
<day>99</day>
<volume>14</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>967-979</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kundur]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Power System Stability and Control]]></source>
<year>1993</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzales]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Periaux]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Srinivas]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Efficient hybrid-game strategies coupled to evolutionary algorithms for robust multidisciplinary design optimization in aerospace engineering]]></article-title>
<source><![CDATA[IEEE Transactions on Evolutionary Computation]]></source>
<year>Apr.</year>
<month> 2</month>
<day>01</day>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>133-150</page-range></nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Xie]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Yan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Fast Online Identification of the Dominant Parameters of Composite Load Model Using Volterra Model and Pattern Classification]]></source>
<year>2007</year>
<conf-name><![CDATA[ Proceedings of IEEE PES General Meeting]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[The Study on Composite Load Model Structure of Artificial Neural Network]]></source>
<year>2008</year>
<conf-name><![CDATA[ Proceedings of 3rd International Conference on Electric Utility Deregulation and Restructuring and Power Technologies]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1564-1570</page-range><publisher-loc><![CDATA[NanJing ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R.-M]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[Z.-Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hill]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reducing Identified Parameters of Measurement-Based Composite Load Model]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>2008</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>76-83</page-range></nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hill]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Load Modeling by Finding Support Vectors of Load Data from Field Measurements]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>May </year>
<month>20</month>
<day>06</day>
<volume>21</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>726-735</page-range></nlm-citation>
</ref>
<ref id="B37">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R.-M]]></given-names>
</name>
<name>
<surname><![CDATA[Hill]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Measurement-based Load Modeling using Genetic Algorithms]]></source>
<year>2007</year>
<conf-name><![CDATA[ Proceedings of IEEE Congress on Evolutionary Computation]]></conf-name>
<conf-loc> </conf-loc>
<page-range>2909-2916</page-range></nlm-citation>
</ref>
<ref id="B38">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zheng]]></surname>
<given-names><![CDATA[X.-Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[Z.-Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Validating Measurement-Based Composite Load Model]]></source>
<year>2009</year>
<conf-name><![CDATA[ Proceedings of 8th International Conference on Advances in Power System Control, Operation and Management]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-6</page-range></nlm-citation>
</ref>
<ref id="B39">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maitra]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gaikwad]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pourbeik]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Brooks]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Load Model Parameter Derivation Using an Automated Algorithm and Measured Data]]></source>
<year>2008</year>
<conf-name><![CDATA[ Proceedings of IEEE PES Conversion and Delivery of Electrical Energy in the 21st Century]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-7</page-range></nlm-citation>
</ref>
<ref id="B40">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mauricio]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Semlyen]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of load characteristics on the dynamic stability of power sy]]></article-title>
<source><![CDATA[IEEE Transactions on Power Apparatus and Systems]]></source>
<year>Nov.</year>
<month> 1</month>
<day>97</day>
<volume>14</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>2295-2304</page-range></nlm-citation>
</ref>
<ref id="B41">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McDonnell]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Reynolds]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Fogel]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Special Session on Applications of evolutionary computation to biology and biochemistry]]></source>
<year>1995</year>
<publisher-name><![CDATA[MIT Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B42">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Milanovic]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Yamashita]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Martinez]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Djokie]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Korunovic]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[International Industry Practice on Power System Load Modeling]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Aug.</year>
<month> 2</month>
<day>01</day>
<volume>28</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B43">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Najafabadi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Alouani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Real time estimation of sensitive parameters of composite power system load model]]></source>
<year>2012</year>
<conf-name><![CDATA[ Proceedings of 2012 IEEE Power and Energy Society Transmission and Distribution Conference and Exposition]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-8</page-range><publisher-loc><![CDATA[Orlando ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B44">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nozari]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kankam]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Price]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aggregation of Induction Motors for Transient Stability Load Modeling]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Nov.</year>
<month> 1</month>
<day>98</day>
<volume>2</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1096-1103</page-range></nlm-citation>
</ref>
<ref id="B45">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ornata]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Uemura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aspects of Voltage Responses of Induction Loads]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Nov.</year>
<month> 1</month>
<day>99</day>
<volume>13</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1337-1344</page-range></nlm-citation>
</ref>
<ref id="B46">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Yan-hong]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Guo-qiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Rui]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Study on the Reduction of Identified Parameters of the Power Load's Aggregated Motor Model with the AIm of Sustaining Its Representabilidad]]></source>
<year>2005</year>
<conf-name><![CDATA[ Proceedings of IEEE PES Transmission and Distribution Conference and Exhibition: Asia and Pacific]]></conf-name>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B47">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pereira]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Kosterev]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mackin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Undrill]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Interim Dynamic Induction Motor Model for Stability Studies in the WSCC]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Nov.</year>
<month> 2</month>
<day>00</day>
<volume>17</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1108-1115</page-range></nlm-citation>
</ref>
<ref id="B48">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rifaat]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[On Composite Load Modeling for Voltage Stability and Under Voltage Load Shedding]]></source>
<year>2004</year>
<conf-name><![CDATA[ Proceedings of IEEE PES General Meeting]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1603-1610</page-range></nlm-citation>
</ref>
<ref id="B49">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodriguez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Perez]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mora]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Particle Swarm Optimization applied in Power System Measurement-Based Load Modeling]]></source>
<year>2013</year>
<conf-name><![CDATA[ Proceedings of IEEE Congress on Evolutionary Computation]]></conf-name>
<conf-loc> </conf-loc>
<page-range>2368-2375</page-range><publisher-loc><![CDATA[Cancún ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B50">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<source><![CDATA[Comparative Research on Power Load Modeling Method in Power Electrical System]]></source>
<year>2012</year>
<conf-name><![CDATA[ Proceedings of Fifth International Conference on Intelligent Computation Technology and Automation (ICICTA)]]></conf-name>
<conf-loc> </conf-loc>
<page-range>455-458</page-range></nlm-citation>
</ref>
<ref id="B51">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Measurement-based load modeling-model structure]]></source>
<year>2003</year>
<conf-name><![CDATA[ Proceedings of IEEE Power-Tech Conference]]></conf-name>
<conf-loc>Bologna </conf-loc>
</nlm-citation>
</ref>
<ref id="B52">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Son]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improvement of Composite Load Modeling Based on Parameter Sensitivity and Dependency Analyses]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>2014</year>
<page-range>242-250</page-range></nlm-citation>
</ref>
<ref id="B53">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cotilla-Sanchez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Brekken]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Load Modeling Methodologies for Cascading Outage Simulation Considering Power System Stability]]></source>
<year>2013</year>
<conf-name><![CDATA[ 1st IEEE Conference on Technologies for Sustainability (SusTech)]]></conf-name>
<conf-loc> </conf-loc>
<page-range>78-85</page-range></nlm-citation>
</ref>
<ref id="B54">
<nlm-citation citation-type="">
<collab>University of Washington</collab>
<source><![CDATA[Electrical Engineering.]]></source>
<year>1999</year>
</nlm-citation>
</ref>
<ref id="B55">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[A New Identification Strategy for Improving Convergence Stability of Load Model Parameters]]></source>
<year>2010</year>
<conf-name><![CDATA[ Proceedings of International Conference on Electrical and Control Engineering]]></conf-name>
<conf-loc> </conf-loc>
<page-range>45-148</page-range></nlm-citation>
</ref>
<ref id="B56">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development of a frequency-dependent composite load model using measurement approach]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>Feb.</year>
<month> 1</month>
<day>99</day>
<volume>9</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1546-1556</page-range></nlm-citation>
</ref>
<ref id="B57">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Xia]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<source><![CDATA[Research on Dunamic Load Modeling Using Back Propagation Neural Network for Electric Power System]]></source>
<year>2006</year>
<conf-name><![CDATA[ Proceedings of International Conference on Power System Technology]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-4</page-range></nlm-citation>
</ref>
<ref id="B58">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wei-guo]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Ren-mu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tie-Qiang]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The induction motor model to reflect dynamic mechanism of synthetic load]]></article-title>
<source><![CDATA[Automation of Electric Power Systems]]></source>
<year>2002</year>
<volume>26</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>23-27</page-range></nlm-citation>
</ref>
<ref id="B59">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power System Load Modeling by Learning Based on System Measurements]]></article-title>
<source><![CDATA[IEEE Transactions on Power Delivery]]></source>
<year>2003</year>
<volume>18</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>364-371</page-range></nlm-citation>
</ref>
<ref id="B60">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Wen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nuttall]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Shimmin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power System Load Modeling by Evolutionary Computation Based on System Measurements]]></article-title>
<source><![CDATA[Electric Power Components and Systems]]></source>
<year>2003</year>
<volume>31</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>423-439</page-range></nlm-citation>
</ref>
<ref id="B61">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xin-ran]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ren-mu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The General Induction Motor Model and its description ability for synthetic loads for electric power system]]></article-title>
<source><![CDATA[Journal of North China Electric Power University]]></source>
<year>1999</year>
<volume>26</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B62">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Meng]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Yao]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multi-Objective Dynamic VAR Planning Against Short-Term Voltage Instability Using a Decomposition-Based Evolutionary Algorithm]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>2014</year>
<volume>29</volume>
<numero>^s6</numero>
<issue>^s6</issue>
<supplement>6</supplement>
<page-range>2813-2822</page-range></nlm-citation>
</ref>
<ref id="B63">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Si]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Qian]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Research on Feasibility of Composite Load Modeling Based on WAMS]]></source>
<year>2011</year>
<conf-name><![CDATA[ Proceedings of 2011 Asia-Pacific Power and Energy Engineering Conference]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-4</page-range><publisher-loc><![CDATA[Wuhan ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B64">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Gen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Introduction to Evolutionary Algorithms (Decision Engineering)]]></source>
<year>2010</year>
<publisher-loc><![CDATA[London ]]></publisher-loc>
<publisher-name><![CDATA[Springer-Verlag]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B65">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zali]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Milanovic]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Generic Model of Active Distribution Network for Large Power System Stability Studies]]></article-title>
<source><![CDATA[IEEE Transactions on Power Systems]]></source>
<year>2013</year>
<volume>28</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>3126-3133</page-range></nlm-citation>
</ref>
<ref id="B66">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bai]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Derivation of Load Model Parameters using Improved Genetic Algorithm]]></source>
<year>2008</year>
<conf-name><![CDATA[ Proceedings of International Conference on Electric Utility Deregulation and Restructuring and Power Technologies]]></conf-name>
<conf-loc> </conf-loc>
<page-range>970-977</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>