<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0123-921X</journal-id>
<journal-title><![CDATA[Tecnura]]></journal-title>
<abbrev-journal-title><![CDATA[Tecnura]]></abbrev-journal-title>
<issn>0123-921X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Distrital Francisco José de Caldas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0123-921X2016000100010</article-id>
<article-id pub-id-type="doi">10.14483/udistrital.jour.tecnura.2016.1.a10</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Tomografía computarizada: proceso de adquisición, tecnología y estado actual]]></article-title>
<article-title xml:lang="en"><![CDATA[Computed tomography: acquisition process, technology and current state]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Espitia Mendoza]]></surname>
<given-names><![CDATA[Óscar Javier]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mejía Melgarejo]]></surname>
<given-names><![CDATA[Yuri Hercilia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Arguello]]></surname>
<given-names><![CDATA[Henry]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Industrial de Santaner  ]]></institution>
<addr-line><![CDATA[Bucaramanga ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Industrial de Santaner  ]]></institution>
<addr-line><![CDATA[Bucaramanga ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Industrial de Santaner  ]]></institution>
<addr-line><![CDATA[Bucaramanga ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2016</year>
</pub-date>
<volume>20</volume>
<numero>47</numero>
<fpage>119</fpage>
<lpage>135</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0123-921X2016000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0123-921X2016000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0123-921X2016000100010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La tomografía computarizada (CT) es una técnica de escaneo no invasivo ampliamente aplicada en sectores como la medicina, la industria y la geología. Esta técnica permite la reconstrucción tridimensional de la estructura interna de un objeto que es iluminado con una fuente de rayos-X. La reconstrucción se forma con imágenes bidimensionales de cortes transversales del objeto. Cada corte se obtiene a partir de las medidas de fenómenos físicos como la atenuación, la dispersión y la difracción de los rayos-X, como resultado de la interacción con el objeto. En general, la adquisición de las medidas se realiza con métodos basados en alguno de estos fenómenos y empleando diversas arquitecturas clasificadas en generaciones. Por otro lado, en respuesta a la necesidad de simular sistemas de adquisición para CT se ha desarrollado software dedicado a esta tarea. El objetivo de este artículo es determinar el estado actual de las técnicas de CT, para esto, se presenta una revisión de los métodos, las distintas arquitecturas usadas para la adquisición y algunas de sus aplicaciones. Adicionalmente, se presentan los resultados de simulaciones realizadas. Las principales contribuciones de este trabajo son la descripción detallada de los métodos de adquisición y la presentación de las posibles tendencias de la técnica en general.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Computed tomography is a noninvasive scan technique widely applied in areas such as medicine, industry, and geology. This technique allows the three-dimensional reconstruction of the internal structure of an object which is lighted with an X-rays source. The reconstruction is formed with two-dimensional cross-sectional images of the object. Each cross-sectional is obtained from measurements of physical phenomena, such as attenuation, dispersion, and diffraction of X-rays, as result of their interaction with the object. In general, measurements acquisition is performed with methods based on any of these phenomena and according to various architectures classified in generations. Furthermore, in response to the need to simulate acquisition systems for CT, software dedicated to this task has been developed. The objective of this research is to determine the current state of CT techniques, for this, a review of methods, different architectures used for the acquisition and some of its applications is presented. Additionally, results of simulations are presented. The main contributions of this work are the detailed description of acquisition methods and the presentation of the possible trends of the technique.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[imágenes médicas]]></kwd>
<kwd lng="es"><![CDATA[métodos de adquisición]]></kwd>
<kwd lng="es"><![CDATA[rayos-X]]></kwd>
<kwd lng="es"><![CDATA[tomografía computarizada]]></kwd>
<kwd lng="en"><![CDATA[computed tomography]]></kwd>
<kwd lng="en"><![CDATA[X-ray]]></kwd>
<kwd lng="en"><![CDATA[X-ray acquisition methods]]></kwd>
<kwd lng="en"><![CDATA[medical imaging]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="Verdana" size="2">     <P>DOI: <a href="http://dx.doi.org/10.14483/udistrital.jour.tecnura.2016.1.a10" target="_blank">http://dx.doi.org/10.14483/udistrital.jour.tecnura.2016.1.a10</a></p>      <p align="center"><font size="4"><b>Tomograf&iacute;a computarizada:  proceso de adquisici&oacute;n, tecnolog&iacute;a y estado actual</b></font></p>      <P align="center"><font size="3"><b>Computed tomography: acquisition process, technology and current state</b></font></p>      <P align="center"><B>&Oacute;scar Javier Espitia Mendoza</B><Sup>1</Sup>, <b>Yuri Hercilia Mej&iacute;a Melgarejo</b><Sup>2</Sup>, <b>Henry Arguello</b><Sup>3</Sup></p>      <p><Sup>1</Sup> Ingeniero de Sistemas, estudiante de Maestr&iacute;a en Ingenier&iacute;a de Sistemas e Inform&aacute;tica de la Universidad Industrial de Santaner. Bucaramanga, Colombia. Contacto: <A href="mailto:oscar.espitia@saber.uis.edu.co">oscar.espitia@saber.uis.edu.co</A>    <br>  <Sup>2</Sup> Ingeniera Electr&oacute;nica, mag&iacute;ster en Ingenier&iacute;a Electr&oacute;nica, estudiante de doctorado en Ingenier&iacute;a Electr&oacute;nica de la Universidad Industrial de Santander. Bucaramanga, Colombia. Contacto: <A href="mailto:yuri.yejia@saber.uis.edu.co">yuri.yejia@saber.uis.edu.co</A>    <br>  <Sup>3</Sup> Ingeniero Electricista, mag&iacute;ster en Potencia El&eacute;ctrica, doctor Electrical and Computer Engineering. Profesor titular de la Universidad Industrial de Santander. Bucaramanga, Colombia. Contacto: <A href="mailto:henarfu@uis.edu.co">henarfu@uis.edu.co</A></p>      <p><B>Fecha de recepci&oacute;n: </B>10 de marzo de 2015<B> Fecha de aceptaci&oacute;n: </B>18 de septiembre de 2015</p>      <p><B>C&oacute;mo citar: </B>Espitia Mendoza, &Oacute;. J., Mej&iacute;a Melgarejo, Y. H., &amp; Arguello Fuentes, H. (2016). Tomograf&iacute;a computarizada: proceso de adquisici&oacute;n, tecnolog&iacute;a y estado actual. <I>Revista Tecnura, 20(47),</I> 119-135. doi: 10.14483/udistrital.jour.tecnura.2016.1.a10</p> <hr>      ]]></body>
<body><![CDATA[<p><b><font size="3">Resumen</font></b></p>      <p>La tomograf&iacute;a computarizada (CT) es una t&eacute;cnica de escaneo no invasivo ampliamente aplicada en sectores como la medicina, la industria y la geolog&iacute;a. Esta t&eacute;cnica permite la reconstrucci&oacute;n tridimensional de la estructura interna de un objeto que es iluminado con una fuente de rayos-X. La reconstrucci&oacute;n se forma con im&aacute;genes bidimensionales de cortes transversales del objeto. Cada corte se obtiene a partir de las medidas de fen&oacute;menos f&iacute;sicos como la atenuaci&oacute;n, la dispersi&oacute;n y la difracci&oacute;n de los rayos-X, como resultado de la interacci&oacute;n con el objeto. En general, la adquisici&oacute;n de las medidas se realiza con m&eacute;todos basados en alguno de estos fen&oacute;menos y empleando diversas arquitecturas clasificadas en generaciones. Por otro lado, en respuesta a la necesidad de simular sistemas de adquisici&oacute;n para CT se ha desarrollado software dedicado a esta tarea. El objetivo de este art&iacute;culo es determinar el estado actual de las t&eacute;cnicas de CT, para esto, se presenta una revisi&oacute;n de los m&eacute;todos, las distintas arquitecturas usadas para la adquisici&oacute;n y algunas de sus aplicaciones. Adicionalmente, se presentan los resultados de simulaciones realizadas. Las principales contribuciones de este trabajo son la descripci&oacute;n detallada de los m&eacute;todos de adquisici&oacute;n y la presentaci&oacute;n de las posibles tendencias de la t&eacute;cnica en general.</p>      <p><B><I>Palabras clave</I>:</B> im&aacute;genes m&eacute;dicas, m&eacute;todos de adquisici&oacute;n, rayos-X, tomograf&iacute;a computarizada.</p> <hr>      <p><b><font size="3">Abstract</font></b></p>      <p>Computed tomography is a noninvasive&nbsp;scan technique widely applied in areas such as medicine, industry, and geology. This technique allows the three-dimensional reconstruction of the internal structure of an object which is lighted with an X-rays source. The reconstruction is formed with two-dimensional cross-sectional images of the object. Each cross-sectional is obtained from measurements of physical phenomena, such as attenuation, dispersion, and diffraction of X-rays, as result of their interaction with the object. In general, measurements acquisition is performed with methods based on any of these phenomena and according to various architectures classified in generations. Furthermore, in response to the need to simulate acquisition systems for CT, software dedicated to this task has been developed. The objective of this research is to determine the current state of CT techniques, for this, a review of methods, different architectures used for the acquisition and some of its applications is presented. Additionally, results of simulations are presented. The main contributions of this work are the detailed description of acquisition methods and the presentation of the possible trends of the technique.</p>      <p><B><I>Keywords</I>:</B> computed tomography, X-ray, X-ray acquisition methods, medical imaging.</p> <hr>      <p><B><font size="3">Introducci&oacute;n</font></b></p>      <p>La tomograf&iacute;a computarizada (CT, por su sigla en ingl&eacute;s) es una tecnolog&iacute;a establecida para obtener im&aacute;genes, de forma no invasiva, de la estructura interna de los objetos en tres dimensiones (3D) (Russo, Lauria, Mettivier y Montesi, 2008). Las tomograf&iacute;as se obtienen a partir de proyecciones bidimensionales usando rayos-X. CT es considerada de gran importancia debido a que brinda mejores posibilidades de diagn&oacute;stico que otros m&eacute;todos como la radiolog&iacute;a convencional (Lewitt, Member, Matej y Member, 2003); adem&aacute;s sus aplicaciones abordan diversas &aacute;reas de investigaci&oacute;n en la actualidad (Maire y Withers, 2014; Mayo <I>et al.</I>, 2002; Jian <I>et al.</I>, 2009; Vontobel, Lehmann y Carlson, 2005; Barroso, Lopes, De Jesus y Oliveira, 2001).</p>      <p>El diagn&oacute;stico por medio de rayos-X ha sido utilizado durante m&aacute;s de 50 a&ntilde;os; los primeros acercamientos a CT pueden ligarse al procedimiento de tomos&iacute;ntesis anal&oacute;gica, que existe desde 1920 (Gehrke y Wirth, 2005; Levakhina, 2013). Sus ra&iacute;ces se encuentran en el descubrimiento de los rayos-X en 1895, por Wilhelm Conrad R&ouml;ntgen, quien logr&oacute; obtener la primera visi&oacute;n de la composici&oacute;n interna de un objeto. En 1917, Radon describi&oacute; de forma matem&aacute;tica la reconstrucci&oacute;n de un objeto desde sus proyecciones. A partir de dichos eventos, la exploraci&oacute;n mediante CT se ha convertido en uno de los m&eacute;todos de diagn&oacute;stico por im&aacute;genes m&aacute;s utilizado (Lewitt, Member, Matej y Member, 2003; Buzug, 2007).</p>      <p>Debido a que con CT convencional no siempre se logran im&aacute;genes del contraste deseado, se desarrollan m&eacute;todos de adquisici&oacute;n que basan sus principios en las diferentes caracter&iacute;sticas de los rayos-X. El m&eacute;todo tradicional de CT, conocido como CT de transmisi&oacute;n (<I>transmission CT</I>), se basa en la obtenci&oacute;n de la atenuaci&oacute;n de los rayos al traspasar un objeto (Webb, 1987). CT de contraste de fase (<I>phase contrast CT</I>) se fundamenta en la adquisici&oacute;n de la medida de los cambios de fase de un haz de rayos-X al pasar a trav&eacute;s de un objeto (Bronnikov, 2006). CT de dispersi&oacute;n (<I>scattering CT</I>) consiste en la reconstrucci&oacute;n de la distribuci&oacute;n de la densidad de electrones en un objeto a partir de la medida de la dispersi&oacute;n dentro de un rango angular (Cong y Wang, 2011). CT de difracci&oacute;n (<I>Diffraction CT</I>) tiene en cuenta propiedades de difracci&oacute;n de los rayos-X (Westmore y F'enster, 1995). CT de doble energ&iacute;a (<I>Dual energy CT</I>) considera la medici&oacute;n de los diferentes valores de atenuaci&oacute;n dados por la proyecci&oacute;n de rayos-X con distinta energ&iacute;a (Johnson, 2012). Recientemente se ha desarrollado la t&eacute;cnica de muestreo compresivo, la cual se ha aplicado a CT convencional y compone un m&eacute;todo conocido como CT compresiva (<I>compressive CT</I>) (Zhu, Wahid y Babyn, 2012).</p>      ]]></body>
<body><![CDATA[<p>Con el fin de explotar la t&eacute;cnica y reducir tiempos de adquisici&oacute;n, se han desarrollado siete generaciones de esc&aacute;neres. Esta clasificaci&oacute;n se da a partir de la disposici&oacute;n de los componentes y el movimiento mec&aacute;nico necesario para recopilar datos. Las generaciones denotan el orden en que se han introducido los dise&ntilde;os; sin embargo, el n&uacute;mero de la generaci&oacute;n no implica que un sistema sea superior a otro (Goldman, 2007; Ghonge, 2013).</p>      <p>En medicina, CT se ha utilizado con &eacute;xito por m&aacute;s de cuatro d&eacute;cadas. Adem&aacute;s, durante varios a&ntilde;os ha ayudado a los ingenieros en ensayos no destructivos de componentes fabricados o en el estudio de diferentes materiales. Recientemente se han desarrollado trabajos de investigaci&oacute;n que se enfocan en incluir la t&eacute;cnica de CT en ciencia de los materiales, geolog&iacute;a e industria (Mayo <I>et al.</I>, 2002; Cong y Wang, 2011; Cho <I>et al.</I>, 2012; Lima <I>et al.</I>, 2009).</p>      <p>El objetivo de esta investigaci&oacute;n es determinar las tendencias y el estado actual de las t&eacute;cnicas de CT, para lo cual se presenta una revisi&oacute;n de los m&eacute;todos de adquisici&oacute;n, se describe la tecnolog&iacute;a usada en las generaciones, las diversas aplicaciones y se muestran los resultados de simulaciones correspondientes a los dos generaciones de CT. Para especificar los resultados del trabajo se plantea la siguiente estructura en el documento: la secci&oacute;n "M&eacute;todos de adquisici&oacute;n" detalla la arquitectura y el modelo para adquisici&oacute;n de proyecciones en cada m&eacute;todo de adquisici&oacute;n CT; la secci&oacute;n "Generaciones CT" describe los aspectos f&iacute;sicos de las generaciones de CT; la secci&oacute;n "Reconstrucci&oacute;n" menciona generalidades sobre reconstrucci&oacute;n; la secci&oacute;n "Aplicaciones CT" presenta algunas aplicaciones actuales de CT; la secci&oacute;n "Casos de prueba" muestra las simulaciones para el m&eacute;todo tradicional de CT, y por &uacute;ltimo, se plantean las conclusiones.</p>      <p><B>M&eacute;todos de adquisici&oacute;n</b></p>      <p>En los &uacute;ltimos a&ntilde;os se han desarrollado formas de medir los cambios de intensidad usando rayos con diferente energ&iacute;a e instrumentos &oacute;pticos que modulan los haces, en busca de mejor calidad y reducci&oacute;n de la dosis. Adem&aacute;s, algunas propiedades f&iacute;sicas de los rayos-X, como la dispersi&oacute;n y difracci&oacute;n, se han tenido en cuenta en las medidas. En las siguientes subsecciones se presentan los principales m&eacute;todos de adquisici&oacute;n de im&aacute;genes tomogr&aacute;ficas basados en estos conceptos.</p>      <p><B>CT de transmisi&oacute;n</b></p>      <p>La <a href="#f1">figura 1</a> muestra la discretizaci&oacute;n de un objeto <i>Q</i> iluminado con luz de rayos-X desde la fuente <I>S</I>. Esta representaci&oacute;n est&aacute; compuesta por voxeles que forman <i>Q</i><sub>1</sub> secciones transversales, cada una con dimensiones superficiales <i>Q</i><sub>2</sub> x <i>Q</i><sub>3</sub>. A cada v&oacute;xel (de dimensiones <i>d<sub>x</sub></i> x <i>d<sub>y</sub></i> <i>d<sub>z</sub></i>) se le asigna una atenuaci&oacute;n <i>&micro;</i>.</p>     <p align="center"><a name="f1"></a><img src="img/revistas/tecn/v20n47/v20n47a01f1.jpg"></p>      <p>Considerando un rayo de intensidad <i>I</i><sub>0</sub>, que atraviesa el objeto con una distribuci&oacute;n no homog&eacute;nea de atenuaciones <i>&micro;</i>(<sub>x</sub>), la intensidad del rayo <i>I</i>(<sub>x</sub>) medida por el detector <I>D</I> depende tanto de la distancia atravesada <I>x</I>, como de la atenuaci&oacute;n <i>&micro;</i>(<i>x</i>) de cada punto en su trayectoria. Esto puede modelarse con la <a href="#ec1">ecuaci&oacute;n (1)</a>.</p>     <p align="center"><a name="ec1"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec1.jpg"></p>      ]]></body>
<body><![CDATA[<p>Este fen&oacute;meno obedece a la ley de Lambert Beer, y puede reescribirse a partir de la <a href="#ec2">ecuaci&oacute;n (2)</a>.</p>     <p align="center"><a name="ec2"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec2.jpg"></p>      <p>La <a href="#ec2">ecuaci&oacute;n (2)</a> se describe como la fracci&oacute;n de luz transmitida a trav&eacute;s del objeto y puede asignarse a una proyecci&oacute;n unidimensional, captada con respecto a un &aacute;ngulo de incidencia. La reconstrucci&oacute;n consiste en estimar la distribuci&oacute;n de los coeficientes de atenuaci&oacute;n <i>&micro;</i>(<i>x</i>) (Buzug, 2007).</p>      <p>Cuando la luz atraviesa un objeto, no solo cambia su intensidad, sino tambi&eacute;n su fase. Los rayos-X pueden ser tratados como ondas electromagn&eacute;ticas. Entonces, un objeto se describe por medio de su &iacute;ndice de refracci&oacute;n <i>n</i>=1-<i>&delta;</i> + <i>i&beta;</i>.  El t&eacute;rmino <i>&delta;</i> corresponde al decremento de la parte real del &iacute;ndice de refracci&oacute;n y la parte imaginaria <i>&beta;</i> describe el &iacute;ndice de absorci&oacute;n. Mediante el uso de estos componentes, el cambio de intensidad se puede expresar a partir de la <a href="#ec3">ecuaci&oacute;n (3)</a>,</p>     <p align="center"><a name="ec3"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec3.jpg"></p>      <p>Donde <i>&lambda;</i> es la longitud de onda de la radiaci&oacute;n. El cambio de fase <i>d&theta;</i> est&aacute; dado por la <a href="#ec4">ecuaci&oacute;n (4)</a>.</p>     <p align="center"><a name="ec4"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec4.jpg"></p>      <p>Donde <i>Q</i><sub>1</sub> es el espesor de la muestra. Cuando los rayos-X pasan a trav&eacute;s de objetos con regiones de diferente densidad y composici&oacute;n, su atenuaci&oacute;n se escribe a partir de la <a href="#ec5">ecuaci&oacute;n (5)</a>.</p>     <p align="center"><a name="ec5"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec5.jpg"></p>      <p>Donde la integraci&oacute;n se hace a lo largo de la trayectoria de los rayos-X. Por otro lado, el desplazamiento de fase <i>d&theta;</i>, causado por la muestra, se escribe como la <a href="#ec6">ecuaci&oacute;n (6)</a>.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="ec6"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec6.jpg"></p>      <p>Esta expresi&oacute;n representa la proyecci&oacute;n de la parte real del &iacute;ndice de refracci&oacute;n. La diferencia entre las dos ecuaciones anteriores est&aacute; en <i>&delta;</i> y <i> &beta;</i>. Por tanto, la reconstrucci&oacute;n en CT de contraste de fase puede realizarse de la misma manera que en CT convencional, mediante la informaci&oacute;n de cambio de fase (Yoneyama, Yamada y Takeda, 2011).</p>      <p>Este m&eacute;todo es el resultado de los esfuerzos para combinar las im&aacute;genes de contraste de fase con CT (Li, Zhu y Sun, 2012), las reconstrucciones obtenidas proporcionan la distribuci&oacute;n de la densidad de electrones del objeto (Bronnikov, 2006). En la actualidad, existen principalmente tres clases de CT de contraste de fase (Jian, 2012). La <a href="#t1">tabla 1</a> muestra las clases de sistemas de CT de contraste de fase.</p>     <p align="center"><a name="t1"></a><img src="img/revistas/tecn/v20n47/v20n47a10t1.jpg"></p>      <p><B>CT de difracci&oacute;n</b></p>      <p>CT de difracci&oacute;n se basa en las propiedades de difracci&oacute;n de los rayos-X, es decir, en la medida de la desviaci&oacute;n de los rayos cuando interact&uacute;an con un objeto. Con esta t&eacute;cnica se puede hacer una discriminaci&oacute;n selectiva de los elementos que componen una muestra escaneada, mediante la fijaci&oacute;n del &aacute;ngulo de Bragg que produzca un pico de interferencia (Barroso <I>et al.</I>, 2000). El diferencial de dispersi&oacute;n de una secci&oacute;n transversal est&aacute; dado por la <a href="#ec7">ecuaci&oacute;n (7)</a>.</p>     <p align="center"><a name="ec7"></a><img src="img/revistas/tecn/v20n47/v20n47a01ec7.jpg"></p>      <p>Donde <i>r</i><sub>c</sub> es el radio del electr&oacute;n 2,82x10<sup>-15</sup>&#91;m&#93;, <i>&theta;</i> es el &aacute;ngulo de difracci&oacute;n, <i>F</i> (<i>q,Z</i>) es el factor de forma at&oacute;mico, <i>q</i> =sin (<i>&theta;</i>/2)/<i>&lambda;</i> es la transferencia de energ&iacute;a cin&eacute;tica. El &aacute;ngulo <i>&theta;</i> entre el haz primario y el haz difractado es el denominado &aacute;ngulo de Bragg. La <a href="#f2">figura 2</a> muestra un esquema del escaneo en CT de difracci&oacute;n.</p>     <p align="center"><a name="f2"></a><img src="img/revistas/tecn/v20n47/v20n47a10f2.jpg"></p>      <p>La radiaci&oacute;n difractada, desde el elemento <i>dx</i> del objeto <I>Q</I> en la posici&oacute;n <I>x</I>, que se capta por el <I>i-</I>&eacute;simo elemento del detector puede expresarse mediante la <a href="#ec8">ecuaci&oacute;n (8)</a>.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="ec8"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec8.jpg"></p>      <p>Donde <i>N</i><sub>0</sub> es el n&uacute;mero de fotones que inciden sobre el objeto, <i>T<sub>p</sub></i>(<i>x</i>) es la transmisi&oacute;n de haz primario a <i>dx</i>, <i>n</i><sub>0</sub> es el n&uacute;mero de centros de difracci&oacute;n por unidad de volumen en <i>x</i>, (<i>d&sigma;/d&Omega;</i>)<sub><i>total</i></sub> es la dispersi&oacute;n coherente e incoherente de la secci&oacute;n transversal por unidad de volumen y por centro de difracci&oacute;n, <I>q</I> representa la transferencia de momento para el elemento de objeto en <i>x</i>, <i>&Delta;&Omega;<sub>i</sub></i>(<i>&theta;,x</i>) es el &aacute;ngulo s&oacute;lido del detector <i>i</i>, <i>T<sub>s</sub></i>(<i>x</i>) la transmisi&oacute;n del haz difractado desde &#119909; hasta el detector y <I>M</I> el componente de difracci&oacute;n m&uacute;ltiple. Es posible reconstruir las im&aacute;genes tomogr&aacute;ficas, basadas en patrones de difracci&oacute;n, con una serie de supuestos simplificadores (Westmore y F'enster, 1995; Westmore, Fenster y Cunningham, 1997; Beath y Cunningham, s.f.).</p>      <p><B>CT de dispersi&oacute;n</b></p>      <p>Despu&eacute;s de que un haz de rayos-X interact&uacute;a con los elementos internos de los tejidos, algunos fotones ser&aacute;n desviados de la direcci&oacute;n de desplazamiento original (<a href="#f3">figura 3</a>), fen&oacute;meno denominado <I>dispersi&oacute;n de fotones</I>. La direcci&oacute;n y la intensidad de los fotones dispersados est&aacute;n directamente relacionados con la distribuci&oacute;n de densidad de electrones dentro del tejido. CT de dispersi&oacute;n consiste en la reconstrucci&oacute;n de la distribuci&oacute;n de la densidad de electrones en un objeto, por medio de la dispersi&oacute;n medida dentro de un rango angular espec&iacute;fico (Cong y Wang, 2011; Yuasa <I>et al.</I>, 2002; Alpuche, Pistorius, Gordon y Elbakri, 2011).</p>     <p align="center"><a name="f3"></a><img src="img/revistas/tecn/v20n47/v20n47a10f3.jpg"></p>      <p>La intensidad de dispersi&oacute;n de rayos-X en la posici&oacute;n <I>x</I> del detector se describe a partir del diferencial de dispersi&oacute;n de fotones en una secci&oacute;n transversal (<a href="#ec9">ecuaci&oacute;n (9)</a>).</p>     <p align="center"><a name="ec9"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec9.jpg"></p>      <p>Donde <I>L</I> es la distancia de la fuente hasta el objeto, <I>&theta;</I> es el &aacute;ngulo de dispersi&oacute;n que est&aacute; dado por <img src="img/revistas/tecn/v20n47/v20n47a10img1.jpg">, <I>v</I> es la direcci&oacute;n del rayo y <i>&rho;</i>(<i>x<sub>s</sub></i>) es la densidad del electr&oacute;n en la posici&oacute;n <i>x<sub>s</sub></i>. Por tanto, la energ&iacute;a de dispersi&oacute;n total, <i>E<sub>dt</sub></i>, adquirida por un detector puede ser formulada a partir de la <a href="#ec10">ecuaci&oacute;n (10)</a>.</p>     <p align="center"><a name="ec10"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec10.jpg"></p>      <p><B>CT de doble energ&iacute;a (DECT)</b></p>      ]]></body>
<body><![CDATA[<p>Las interacciones entre los rayos-X, con energ&iacute;a fot&oacute;nica entre 30 <I>keV</I> y 200 <I>keV</I>, y la materia est&aacute;n dominadas por la dispersi&oacute;n Compton y el efecto fotoel&eacute;ctrico. Estos &uacute;ltimos son dependientes tanto de los materiales como de la energ&iacute;a y cada uno de ellos se modela a partir de la <a href="#ec11">ecuaci&oacute;n (11)</a>.</p>     <p align="center"><a name="ec11"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec11.jpg"></p>      <p>Donde (<i>x,y,z</i>) son las coordenadas de la muestra, <i>&micro;</i>(<i>x,y,z,E</i>) es la atenuaci&oacute;n total, <I>E</I> es la energ&iacute;a incidente, <i>a<sub>c</sub></i>(<i>x,y,z</i>) es el coeficiente de Compton, <i>&alpha;<sub>p</sub></i>(<i>x,y,z</i>) es el coeficiente fotoel&eacute;ctrico, <i>&fnof;KN</i>(<I>E</I>) es el diferencial de dispersi&oacute;n de Compton o dispersi&oacute;n incoherente y <I>&fnof;<SUB>p</SUB></I>(<I>E</I>) se aproxima a la dependencia de energ&iacute;a de la interacci&oacute;n fotoel&eacute;ctrica (<a href="#ec12">ecuaci&oacute;n (12)</a>).</p>     <p align="center"><a name="ec12"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec12.jpg"></p>      <p>Los coeficientes son funciones de las propiedades f&iacute;sicas de los materiales, como la masa, la densidad y el n&uacute;mero at&oacute;mico. Un esc&aacute;ner de CT de doble energ&iacute;a obtiene dos conjuntos de proyecciones logar&iacute;tmicas descritas en las <a href="#ec13">ecuaciones (13)</a> y (<a href="#ec14">14</a>).</p>     <p align="center"><a name="ec13"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec13.jpg"></p>     <p align="center"><a name="ec14"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec14.jpg"></p>      <p>Donde <img src="img/revistas/tecn/v20n47/v20n47a10img2.jpg"> corresponden a las proyecciones con baja y alta energ&iacute;a, respectivamente, <img src="img/revistas/tecn/v20n47/v20n47a10img3.jpg"> son los espectros de rayos-X incidentes de baja y alta energ&iacute;a, respectivamente (Ying, Z.; Naidu, R. &amp; Crawford, 2006; Zhang <I>et al.</I>, 2013). En general, las proyecciones se adquieren mediante tres mecanismos: DECT de conmutaci&oacute;n r&aacute;pida de kilovoltaje, donde la fuente var&iacute;a la energ&iacute;a de radiaci&oacute;n dentro de un rango definido; DECT de doble fuente, en el cual se usan dos fuentes independientes para cubrir el campo de visi&oacute;n desde dos puntos distintos; y DECT de detector multicapa, que posee dos capas de detectores con diferente sensibilidad (Johnson, 2012; Kaza <I>et al.</I>, 2012). En la <a href="#f4">figura 4</a> se muestra un esquema de los sistemas mencionados.<img src="img/revistas/tecn/v20n47/v20n47a10img4.jpg"></p>     <p align="center"><a name="f4"></a><img src="img/revistas/tecn/v20n47/v20n47a10f4.jpg"></p>      <p><B>CT compresiva</b></p>      ]]></body>
<body><![CDATA[<p>El muestreo compresivo (CS de su sigla en ingl&eacute;s) es una nueva teor&iacute;a para adquirir y reconstruir se&ntilde;ales (Donoho, 2006). A diferencia del proceso de adquisici&oacute;n de se&ntilde;ales tradicional, la teor&iacute;a de CS permite que las se&ntilde;ales compresibles sean muestreadas a una frecuencia cercana a su tasa de informaci&oacute;n intr&iacute;nseca, que est&aacute; muy por debajo de la tasa de Nyquist (Shannon, 1998). CS se fundamenta en dos condiciones: a) que las se&ntilde;ales digitales sean dispersas y b) la incoherencia de la matriz de medici&oacute;n (Wakin, 2008).</p>      <p>Se dice que una imagen es dispersa si la mayor&iacute;a de sus elementos est&aacute;n cerca o son iguales a cero. Asumiendo un proceso de medici&oacute;n lineal que calcula <i>M &laquo; N</i> productos internos entre <I>&fnof;</I> y una colecci&oacute;n de vectores <img src="img/revistas/tecn/v20n47/v20n47a10img5.jpg"> como <img src="img/revistas/tecn/v20n47/v20n47a10img6.jpg"> (<a href="#ec15">ecuaci&oacute;n (15)</a>).</p>     <p align="center"><a name="ec15"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec15.jpg"></p>      <p>Donde el conjunto de proyecciones <i>y<sub>i</sub></i> forman el vector <I>y</I> de <I>M</I> elementos, &Phi; es la matriz de medici&oacute;n con dimensiones <i>M X N</i>, con filas <img src="img/revistas/tecn/v20n47/v20n47a10img7.jpg"> y &fnof; es la se&ntilde;al de rayos-X original. Teniendo en cuenta la reconstrucci&oacute;n de &fnof; a partir de <I>y</I>, se sabe que existen infinitas soluciones para la ecuaci&oacute;n (15), porque la dimensionalidad de <I>y </I>es mucho menor que la de &fnof;.</p>      <p>Un requisito clave para la aplicaci&oacute;n de la teor&iacute;a de CS es que la imagen sea dispersa. Muchas de las se&ntilde;ales de la naturaleza se pueden volver dispersas adoptando una transformaci&oacute;n adecuada con un n&uacute;mero peque&ntilde;o de coeficientes (Cand&egrave;s, Romberg y Tao, 2006; Sevak, Thakkar, Kher y Modi, 2012).</p>      <p>Matem&aacute;ticamente, una se&ntilde;al discreta <img src="img/revistas/tecn/v20n47/v20n47a10img8.jpg"> puede ser expresada a partir de la <a href="#ec16">ecuaci&oacute;n (16)</a>.</p>     <p align="center"><a name="ec16"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec16.jpg"></p>      <p>Donde <I>x</I> es la secuencia de coeficientes de <I>f</I> y la base &psi; es una matriz con columnas <i>&phi;</i><sub>1</sub>,...<i>&phi;<sub>G</sub></i> Claramente, <I>f</I> y <I>x</I> son representaciones equivalentes de la misma se&ntilde;al, <I>f</I> es una combinaci&oacute;n lineal de apenas <I>F</I> vectores base, con <i>F &laquo; G</i>  (Shannon, 1998), (Wakin, 2008). De acuerdo con las <a href="#ec15">ecuaciones (15)</a> y (<a href="#ec16">16</a>) se obtiene la <a href="#ec17">ecuaci&oacute;n (17)</a>.</p>     <p align="center"><a name="ec17"></a><img src="img/revistas/tecn/v20n47/v20n47a10ec17.jpg"></p>      <p>CS se ha usado como base para la reconstrucci&oacute;n en CT de transmisi&oacute;n y de dispersi&oacute;n (Bronnikov, 2006; Choi y Brady, 2009; Yu y Wang, 2009; Chen <I>et al.</I>, 2012). Una forma de implementar la teor&iacute;a de CS en una configuraci&oacute;n de CT de transmisi&oacute;n es incluir elementos en el sistema que permitan codificar las medidas para tomar muestras comprimidas. Estos elementos pueden ser aperturas codificadas, debido a los efectos que tienen sobre la luz (Galvis, Mej&iacute;a y Arg&uuml;ello, 2014; Cand&egrave;s y Tao, 2006). Las aperturas codificadas corresponden a arreglos bidimensionales con patrones de materiales opacos a la luz, las secciones que no contienen material opaco definen su transmitancia, es decir, la fracci&oacute;n de luz que puede atravesarlas (MacCabe, Holmgren, Tornai y Brady, s.f.; Choi y Brady, 2009). En la <a href="#f5">figura 5</a> se muestra un esquema de un sistema de muestreo para CT con la inclusi&oacute;n de las aperturas codificadas T<sup>1</sup> y T<sup>2</sup>, que modulan los haces proyectados desde las fuentes S<sup>1</sup> y S<sup>2</sup> y  hacia un plano de m&uacute;ltiples detectores que miden la atenuaci&oacute;n generada por un objeto <img src="img/revistas/tecn/v20n47/v20n47a10img9.jpg"></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f5"></a><img src="img/revistas/tecn/v20n47/v20n47a10f5.jpg"></p>      <p>Este m&eacute;todo se ha introducido con ventajas en cuanto a los tiempos de adquisici&oacute;n y dosis de radiaci&oacute;n. Con un sistema de CS para CT, se reducen las medidas y el tiempo para tomarlas, lo que significa que un objeto bajo estudio se expone a una cantidad menor de radiaci&oacute;n (Choi y Brady, 2009).</p>      <p><B>Generaciones de CT</b></p>      <p>Un sistema de CT posee dos piezas claves: una fuente de rayos-X y un detector o arreglo de detectores. En las fuentes se producen fotones con alta energ&iacute;a por medio de aceleraci&oacute;n y desaceleraci&oacute;n de electrones. Por otro lado, los detectores miden la cantidad de luz que pasa a trav&eacute;s del objeto bajo estudio. Las fuentes, por lo general, son tubos de rayos-X. Sin embargo, existen trabajos y aplicaciones en las que se usa el sincrotr&oacute;n. Actualmente, los detectores son de estado s&oacute;lido, anal&oacute;gicos o digitales, usan celdas electr&oacute;nicas y fotodiodos para hacer conteo de fotones. El desarrollo tecnol&oacute;gico referente a CT se ha enfocado en estas dos piezas espec&iacute;ficamente, as&iacute; que sus caracter&iacute;sticas definen cada generaci&oacute;n (Shefer <I>et al.</I>, 2013).</p>      <p>Previo a la introducci&oacute;n de la tecnolog&iacute;a de los esc&aacute;neres CT se estableci&oacute; la tomos&iacute;ntesis, una t&eacute;cnica tomogr&aacute;fica que produce un conjunto de im&aacute;genes de cortes transversales apilados, a partir de un n&uacute;mero limitado de proyecciones, con bajas dosis de radiaci&oacute;n, adquiridas dentro de un campo angular limitado (Dobbins, 2009). En la <a href="#f6">figura 6</a> se muestra la geometr&iacute;a de un esc&aacute;ner de tomos&iacute;ntesis.</p>     <p align="center"><a name="f6"></a><img src="img/revistas/tecn/v20n47/v20n47a10f6.jpg"></p>      <p>A&ntilde;os despu&eacute;s, en la d&eacute;cada de 1970 se impuls&oacute; el desarrollo de tecnolog&iacute;as que mejoraran el alcance de esta t&eacute;cnica, punto de partida para las denominadas generaciones CT. En <a href="#t2">tabla 2</a> se presentan los principales aspectos de cada generaci&oacute;n y la descripci&oacute;n de la geometr&iacute;a correspondiente.</p>     <p align="center"><a name="t2"></a><img src="img/revistas/tecn/v20n47/v20n47a10t2.jpg"></p>      <p>En los &uacute;ltimos a&ntilde;os se han desarrollado formas de medir los cambios de intensidad usando m&uacute;ltiples fuentes e instrumentos &oacute;pticos que modulan los haces, en busca de mejor calidad y reducci&oacute;n de la dosis.</p>      <p>Recientemente se han propuesto sistemas basados en la influencia del n&uacute;mero de fuentes de rayos-X sobre las reconstrucciones de CT. Por ejemplo, los sistemas <I>Pioneering Dynamic Spatial Reconstructor of Mayo Clinic</I> (Wang, Yu De Mann, 2008), <I>Line Sources</I> CT (Bharkhada y Yu, 2009), <I>Inverse-Geometry CT</I> y <I>Ultimately a Rebirth of Stationary CT</I> (Niemi, Lassas y Siltanen, 2013) poseen m&uacute;ltiples fuentes de rayos-X distribuidas de diversas maneras. El uso de m&aacute;s de una fuente permite disminuir el tiempo de adquisici&oacute;n de los datos, y por tanto, reducir la dosis de radiaci&oacute;n. Aunque los desarrollos en tecnolog&iacute;as de adquisici&oacute;n se han centrado en los sistemas de detecci&oacute;n, se espera que los pr&oacute;ximos avances se enfoquen en el uso de m&uacute;ltiples fuentes de rayos-X.</p>      ]]></body>
<body><![CDATA[<p><B>Reconstrucc&oacute;n</b></p>      <p>El problema de la reconstrucci&oacute;n consiste en calcular la estructura del objeto bajo estudio a partir de las medidas de intensidad, determinadas por el efecto fotoel&eacute;ctrico, la dispersi&oacute;n y la difracci&oacute;n. La adquisici&oacute;n de los datos deja como resultado una matriz conocida como sinograma, de la cual se obtiene una imagen bidimensional correspondiente a un corte transversal. Existen m&eacute;todos anal&iacute;ticos o iterativos esta tarea. Los m&eacute;todos anal&iacute;ticos comprenden herramientas matem&aacute;ticas propias del an&aacute;lisis de Fourier como el teorema de proyecciones y la convoluci&oacute;n; entre estos se encuentran la retroproyecci&oacute;n y la retroproyecci&oacute;n filtrada (FBP). Los m&eacute;todos iterativos incluyen el m&eacute;todo algebraico y los m&eacute;todos estad&iacute;sticos (Buzug, 2007).</p>      <p><B>Aplicaciones de CT</b></p>      <p>CT es considerada una tecnolog&iacute;a avanzada que tiene una amplia aplicaci&oacute;n en la medicina. Ha permitido ensayos no destructivos en otras &aacute;reas como la geolog&iacute;a, la ingenier&iacute;a y la industria. A continuaci&oacute;n, se resaltan las generalidades sobre las aplicaciones en estas &aacute;reas. Su selecci&oacute;n se debe al impacto que tienen y al inter&eacute;s que han despertado en diversos sectores de Colombia.</p>      <p><B>Medicina</b></p>      <p>En medicina, CT es un procedimiento aceptado para diagn&oacute;stico, gu&iacute;a en procedimientos o monitoreo de la efectividad de los tratamientos para enfermedades como el c&aacute;ncer (Uriondo, Garc, Deustotech-life y Avda, 2011; Kapadia <I>et al.</I>, 2008). Mediante esc&aacute;neres CT se obtienen im&aacute;genes de alto contraste en las que es posible identificar traumas &oacute;seos o tumores y estudiar &oacute;rganos en tiempo real. En la actualidad, CT se usa en procedimientos como fluoroscopia, im&aacute;genes y visualizaci&oacute;n 3D, angiograf&iacute;a e im&aacute;genes cardiacas.</p>      <p>La fluoroscopia es un procedimiento de diagn&oacute;stico en el que se estudian las estructuras del cuerpo en movimiento en tiempo real, esto se logra con una tasa de procesamiento muy alta (Goldman, 2007; Su <I>et al.</I>, 2013). La visualizaci&oacute;n 3D es una t&eacute;cnica de CT usada en planeaci&oacute;n de tratamientos, im&aacute;genes craneofaciales, planeaci&oacute;n de cirug&iacute;as y ortopedia (Geng y Member, 2008). La angiograf&iacute;a es la CT de los vasos sangu&iacute;neos, opacados por medios de contraste, en este procedimiento se escanea el &aacute;rea de inter&eacute;s durante la inyecci&oacute;n de contraste y las im&aacute;genes se registran cuando los vasos est&aacute;n completamente opacados para mostrar la condici&oacute;n arterial o venosa (Ning <I>et al.</I>, 2000). Con el desarrollo de esc&aacute;neres que reducen los efectos del movimiento continuo del coraz&oacute;n se logran im&aacute;genes card&iacute;acas, dando amplias posibilidades de diagn&oacute;stico de enfermedades (Liu, Member, Fernando y Sinusas, 2006).</p>      <p>Recientemente, CT se usa para obtener im&aacute;genes de las personas sanas, como un medio para la detecci&oacute;n temprana de enfermedades. Este concepto se conoce como <I>CTscreening</I> y es investigado como una herramienta potencial para obtener im&aacute;genes de individuos asintom&aacute;ticos (Seeram, 2008).</p>      <p><B>Geolog&iacute;a</b></p>      <p>Aunque CT fue introducido como un procedimiento m&eacute;dico, se ha reconocido su uso en otras &aacute;reas como geolog&iacute;a e ingenier&iacute;a. Las primeras aplicaciones incluyen estudios en los campos de la ciencia del suelo, meteoritos, paleontolog&iacute;a, geotecnia y la geolog&iacute;a del petr&oacute;leo. En la actualidad, se usa CT de alta resoluci&oacute;n (micro y nano CT) (Ketcham y Carlson, 2001) en la inspecci&oacute;n de muestras geol&oacute;gicas para la exploraci&oacute;n de recursos.</p>      ]]></body>
<body><![CDATA[<p>Los sistemas CT de alta resoluci&oacute;n proporcionan im&aacute;genes tridimensionales a nivel microsc&oacute;pico de las muestras. En la ciencia del suelo, las muestras son escaneadas para visualizar estructura, componentes o ra&iacute;ces, por ejemplo, para optimizaci&oacute;n de cultivos o productividad (Taina, Heck, Deen y Ma, 2013). CT se aplica a muestras de meteoritos con el fin de determinar caracter&iacute;sticas como la edad y su composici&oacute;n qu&iacute;mica (Ketcham y Carlson, 2001). Tambi&eacute;n, se considera una t&eacute;cnica que brinda amplias posibilidades para estudiar f&oacute;siles (Vontobel, Lehmann y Carlson, 2005). Por otro lado, se usa para el an&aacute;lisis cualitativo y cuantitativo de las caracter&iacute;sticas internas de los materiales asf&aacute;lticos y cementos en el &aacute;rea de la geotecnia (Hu <I>et al.</I>, 2012). En la geolog&iacute;a del petr&oacute;leo es un importante avance en este momento en pa&iacute;ses como Colombia. Este procedimiento ayuda a revelar los detalles de la estructura interna de los poros de una roca petrol&iacute;fera y a comprender las condiciones que afectan la producci&oacute;n del hidrocarburo (Riepe y Suhaimi, 2011; Knackstedt <I>et al.</I>, 2013).</p>      <p><B>Industria</b></p>      <p>En la industria, CT se ha usado por varios a&ntilde;os en ensayos no destructivos de los elementos fabricados. Uno de los usos m&aacute;s estudiados en la actualidad se relaciona con los sistemas de detecci&oacute;n de explosivos. Tambi&eacute;n se ha investigado en el estudio de materiales fabricados y manejo de residuos peligrosos.</p>      <p>En los aeropuertos se usan esc&aacute;neres de CT para explorar el equipaje y detectar explosivos a partir de la densidad, masa y otras propiedades de los objetos en el interior de los contenedores (Ying, Naidu y Crawford, 2006; Gang y Yi, 2009). Por otra parte en las grandes f&aacute;bricas se usa el escaneo en control de calidad, ya que con CT es posible hacer estudios no destructivos de los productos fabricados (Gehrke y Wirth, 2005; Malcolm, Liu, Ng y Teng, 2013). Por &uacute;ltimo, ha sido aplicado en el manejo de residuos peligrosos, como herramienta para determinar condiciones del contenido de los recipientes en que se depositan desechos que emiten radiaci&oacute;n (Bernardi y Martz, 1995).</p>      <p>La <a href="#f7">figura 7</a> muestra tres ejemplos de tomograf&iacute;as: a) una imagen card&iacute;aca (Chong y Essue, 2010), b) la reconstrucci&oacute;n de los poros de un n&uacute;cleo de granito (UGCT, 2015) y c) el modelo tridimensional obtenido del escaneo de un microchip (UGCT, 2015). Estas im&aacute;genes corresponden a resultados de investigaciones en medicina, geolog&iacute;a e industria, respectivamente.</p>     <p align="center"><a name="f7"></a><img src="img/revistas/tecn/v20n47/v20n47a10f7.jpg"></p>      <p>En la <a href="#t3">tabla 3</a> se presenta un resumen de los m&eacute;todos de adquisici&oacute;n y sus respectivas aplicaciones.</p>     <p align="center"><a name="t3"></a><img src="img/revistas/tecn/v20n47/v20n47a10t3.jpg"></p>      <p>CT es aplicada ampliamente y se posiciona como uno de los procedimientos radiol&oacute;gicos m&aacute;s usados e investigados en la actualidad para ensayos no destructivos. Por otro lado, el m&eacute;todo de transmisi&oacute;n es el m&aacute;s explotado, esto quiz&aacute; se deba a que corresponde al m&eacute;todo tradicional. Adem&aacute;s, el &aacute;rea de la que m&aacute;s datos de investigaciones se tienen es la medicina.</p>      <p>En la <a href="#f8">figura 8</a> se muestra el comportamiento de la literatura referente a aplicaciones de CT en las &aacute;reas mencionadas anteriormente en los &uacute;ltimos 15 a&ntilde;os, el m&aacute;ximo de publicaciones por a&ntilde;o es seis y el m&iacute;nimo es uno. Se evidencia un mayor n&uacute;mero de publicaciones en aplicaciones m&eacute;dicas y es posible inferir un creciente auge de la aplicaci&oacute;n de la t&eacute;cnica en geolog&iacute;a.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f8"></a><img src="img/revistas/tecn/v20n47/v20n47a10f8.jpg"></p>      <p><B>Casos de prueba</b></p>      <p>Dentro del <I>software</I> para simulaciones de CT se destacan las herramientas de Astra, un paquete del <I>software</I> Matlab de c&oacute;digo abierto desarrollado para tomograf&iacute;a (Astra Tomography Toolbox, s.f.). Este permite simular el procedimiento con distintas geometr&iacute;as, correspondientes a las generaciones. Est&aacute; basado en el m&eacute;todo de transmisi&oacute;n, debido a que se reconstruye la estructura espacial mediante la estimaci&oacute;n de coeficientes de atenuaci&oacute;n a partir de medidas de intensidad. Por &uacute;ltimo, Astra contiene los algoritmos de reconstrucci&oacute;n mencionados en la secci&oacute;n "Reconstrucci&oacute;n".</p>      <p>El trabajo de la herramienta comienza con la generaci&oacute;n de datos sint&eacute;ticos que corresponden al objeto a escanear y la definici&oacute;n de la geometr&iacute;a de proyecci&oacute;n. Con esta informaci&oacute;n se calculan las proyecciones y se genera el sinograma. Adicionalmente, se definen las dimensiones, distancias, los &aacute;ngulos de proyecci&oacute;n y el tipo de algoritmo de reconstrucci&oacute;n. La <a href="#f9">figura 9</a> muestra un ejemplo de una simulaci&oacute;n realizada con dos geometr&iacute;as, la geometr&iacute;a en paralelo y la geometr&iacute;a en abanico. Las im&aacute;genes de muestra tienen dimensiones de 128 por 128 p&iacute;xeles, 256 detectores, 500 &aacute;ngulos y un rango de 360 grados para el desplazamiento de la fuente. La (a) presenta una imagen fantasma (<I>phantom</I>), usada tradicionalmente para representar el objeto escaneado en CT; la (b) y (c) ilustran los sinogramas correspondientes a los experimentos simulados con geometr&iacute;as en paralelo y en abanico, respectivamente; las (d) y (e) muestran los resultados de la reconstrucci&oacute;n, realizada con el algoritmo FBP para cada experimento.</p>     <p align="center"><a name="f9"></a><img src="img/revistas/tecn/v20n47/v20n47a10f9.jpg"></p>      <p>Una herramienta para expresar resultados de forma cuantitativa es el c&aacute;lculo del PSNR (<I>Peak Signal-to-Noise Ratio)</I>. La diferencia entre las reconstrucciones de las <a href="#f9">figuras 9(d)</a> y <a href="#f9">9(e)</a> se calcula con el PSNR, que es de 27,81 y 32,47 &#91;dB&#93;, respectivamente. Esto se debe a la cantidad de medidas por &aacute;ngulo. Mientras se mide una proyecci&oacute;n lineal con una arquitectura en paralelo, se toman varias proyecciones del mismo tipo con una configuraci&oacute;n en abanico. Por tanto, se espera que la reconstrucci&oacute;n con la configuraci&oacute;n en abanico sea mejor, lo que se verifica con los valores de PSNR obtenidos.</p>      <p><font size="3"><b>Conclusiones</b></font></p>      <p>CT es una herramienta importante en varias &aacute;reas de investigaci&oacute;n. Como se mostr&oacute; en esta revisi&oacute;n, desde los a&ntilde;os 1970, el uso de rayos-X en ensayos no destructivos est&aacute; envuelto en una continua evoluci&oacute;n, que comprende aspectos f&iacute;sicos, algor&iacute;tmicos y tecnol&oacute;gicos.</p>      <p>Este avance se da como respuesta a las necesidades generadas por el uso de la t&eacute;cnica, como por ejemplo disminuir los tiempos de adquisici&oacute;n y aumentar el nivel de detalle en las reconstrucciones. Una de las preocupaciones latentes es la dosis de radiaci&oacute;n. Para responder a esta preocupaci&oacute;n se ha investigado un nuevo m&eacute;todo de adquisici&oacute;n usando la teor&iacute;a de muestreo compresivo. Adem&aacute;s de establecer el estado actual del CT, en esta revisi&oacute;n se presentan los primeros trabajos enfocados en la t&eacute;cnica de muestreo compresivo aplicada al m&eacute;todo tradicional.</p>      <p>CT se ha destacado como un procedimiento m&eacute;dico, sin embargo, como se detall&oacute; en este trabajo, se evidencia su impacto en la industria y en la geolog&iacute;a. Se espera que parte de las pr&oacute;ximas investigaciones en CT est&eacute;n dedicadas a estas &aacute;reas. Por otro lado, Aunque los desarrollos en tecnolog&iacute;as de adquisici&oacute;n se han centrado en los sistemas de detecci&oacute;n, se espera que los pr&oacute;ximos avances se enfoquen en el uso de m&uacute;ltiples fuentes de rayos-X.</p>      ]]></body>
<body><![CDATA[<p><B>Agradecimientos</b></p>      <p>Los autores agradecen a la Vicerrector&iacute;a de Investigaci&oacute;n y Extensi&oacute;n de la Universidad Industrial de Santander por apoyar este trabajo registrado bajo el proyecto "Dise&ntilde;o y simulaci&oacute;n de una arquitectura de tomograf&iacute;a computarizada para el censado compresivo de im&aacute;genes de rayos-X" (c&oacute;digo VIE 1803).</p> <hr>      <p><b><font size="3">Referencias</font></b></p>      <!-- ref --><p>Alpuche, J.E.; Pistorius, S.; Gordon, R. &amp; Elbakri, I.A. (2011). A Novel Hybrid Reconstruction Algorithm for First Generation Incoherent Scatter CT (ISCT) of Large Objects with Potential Medical Imaging Applications. <I>Journal of X-Ray Science and Technology. 19</I>(1), 35-56.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0123-921X201600010001000001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Astra Tomography Toolbox (s.f.). <I>A High-Performance GPU MATLAB Toolbox for 2D and 3D Tomography.</I> Recuperado de: <a href="http://sourceforge.net/p/astra-toolbox/wiki/Introduction/" target="_blank">http://sourceforge.net/p/astra-toolbox/wiki/Introduction/</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0123-921X201600010001000002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Barroso, R.C.; Lopes, R.T.; De Jesus, E.F.O. &amp; Oliveira, L.F. (2001). X-Ray diffraction Microtomography Using Synchrotron Radiation. <I>Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 471</I>(2), 75-79.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0123-921X201600010001000003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Barroso, R.C.; Lopes, R.T.; Jesus, E.F.O.; De Oliveira, L.F. &amp; Description, A.B. (2000). Synchrotron Biomedical Applications Using X-Ray Diffraction Tomography. En: <I>IEEE Conference Record, Nuclear Science Symposium. 2</I>, 855-859. Seattle, WA.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0123-921X201600010001000004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Beath, S.R. &amp; Cunningham, I.A. (s.f.) (2009). Pseudo-Monoenergetic X-Ray Diffraction Measurements Using Balanced Filters for Coherent-Scatter Computed Tomography. <I>Medical Physics. 36</I>(5), 1839-1847.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0123-921X201600010001000005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Bernardi, R.T. &amp; Martz, H. E. (1995). Nuclear Waste Drum Characterization with 2 MeV X-Ray and Gamma-Ray Tomography. <I>Proc. SPIE 2519, X-Ray and Ultraviolet Sensors and Applications</I>, <I>140. </I>DOI:10.1117/12.211897.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0123-921X201600010001000006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Bharkhada, H. &amp; Yu, H.L. (2009). Line-source based X-ray tomography. International <I>Journal of Biomedical Imaging</I>. DOI:10.1155/2009/534516<I>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0123-921X201600010001000007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></I></p>      <!-- ref --><P>Bronnikov, A.V. (2006). Phase-Contrast CT: Fundamental Theorem and Fast Image Reconstruction Algorithms. <I>SPIE, Developments in X-Ray Tomography</I>, 63180Q, DOI:10.1117/12.679389.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0123-921X201600010001000008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Buzug, T.M. (2007). <I>Computed Tomography: From Photon Statistics to Modern Cone-Beam CT. </I>Berl&iacute;n-Heidelberg: Springer Verlag.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0123-921X201600010001000009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Candes, E.J. &amp; Tao, T. (2006). Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies? <I>IEEE Transactions on Information Theory. 52</I>(12), 5406-5425.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0123-921X201600010001000010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Cand&egrave;s, E.J.; Romberg, J. &amp; Tao, T. (2006). Robust Uncertainty Principles: Exact Signal Reconstruction From Highly Incomplete Frequency Information. <I>IEEE Transactions on Information Theory. 52</I>(2), 489-509.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0123-921X201600010001000011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Changizi, V., Oghabian, M. A., Speller, R., Sarkar, S., &amp; Kheradmand, A. A. (2005). Application of Small Angle X-ray Scattering (SAXS) for Differentiation between Normal and Cancerous Breast Tissue. <I>Int J Med Sci. 2</I>(3), 118-121.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0123-921X201600010001000012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Chen, J.; Member, S.; Cong, J.; Vese, L.A. &amp; Villasenor, J. (2012). A Hybrid Architecture for Compressive Sensing 3-D CT Reconstruction. <I>IEEE Journal on Emerging and Selected Topics in Circuits and Systems. 2</I>(3), 616-625.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0123-921X201600010001000013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Cho, M.K.; Youn, H.; Jang, S.Y.; Lee, S.; Han, M.C. &amp; Kim, H.K. (2012). Digital Tomosynthesis in Cone-Beam Geometry for Industrial Applications: Feasibility and Preliminary Study. <I>International Journal of Precision Engineering and Manufacturing. 13</I>(9), 1533-1538.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0123-921X201600010001000014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Choi, K. &amp; Brady, D.J. (2009). Coded Aperture Computed Tomography. En: <I>Proc. SPIE 7468, Adaptive Coded Aperture Imaging, Non-Imaging, and Unconventional Imaging Sensor Systems</I>, 74680B. DOI:10.1117/12.825277.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S0123-921X201600010001000015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Chong, J. &amp; Essue, J. (2008). Innovations in Cardiac Computed Tomography: Cone Beam CT/Volume CT and Dual Source CT. <I>UWOMJ 77</I>(2), 6-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S0123-921X201600010001000016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Cong, W. &amp; Wang, G. (2011). X-Ray Scattering Tomography for Biological Applications. <I>J. Xray. Sci. Technol. 19</I>(2), 219-227.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S0123-921X201600010001000017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Darshini P., and Karandharaj, P. (2014). Medical image processing schemes for cancer detection: A survey. In <I>International Conference on Green Computing Communication and Electrical Engineering</I> (pp. 1-6).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000160&pid=S0123-921X201600010001000018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Dobbins, J.T. (2009). Tomosynthesis Imaging: At a Translational Crossroads. <I>Medical Physics. 36</I>(6), 1956--1967. DOI:10.1118/1.3120285.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000162&pid=S0123-921X201600010001000019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Donoho, D.L. (2006). Compressed Sensing. <I>IEEE Transactions on Information Theory. 52</I>(4), 1289-1306.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000164&pid=S0123-921X201600010001000020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Galvis, D.F.; Mej&iacute;a, Y.H. &amp; Arg&uuml;ello, H. (2014). Efficient Reconstruction of Raman Spectroscopy Imaging Based on Compressive Sensing. <I>DYNA. 81</I>(118), 116-124.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000166&pid=S0123-921X201600010001000021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Gang, T. &amp; Ji, F.D. (2009). The Research &amp; Application of the Detection Capability of Dangerous Goods in Dual-Energy X-Ray Security Equipment. In <I>IEEE International Conference on Intelligent Computation Technology and Automation. 2</I>, 352-355. DOI: 10.1109/ICICTA.2009.321.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000168&pid=S0123-921X201600010001000022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Gehrke S. &amp; Wirth, K.E. (2005). Application of Conventional- and Dual-Energy X-Ray Tomography in Process Engineering. <I>IEEE Sens. J. 5</I>(2), 183-187.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000170&pid=S0123-921X201600010001000023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Geng, J. &amp; Member, S. (2008). Volumetric 3D Display for Radiation Therapy Planning. <I>Journal of Display Technology. 4</I>(4), 437-450.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000172&pid=S0123-921X201600010001000024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Ghonge, N.P. (2013). Computed Tomography in the 21st Century: Current Status &amp; Future Prospects. <I>JIMSA 26</I>(1), 35-42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000174&pid=S0123-921X201600010001000025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Goldman, L.W. (2007). Principles of CT and CT Technology. <I>J. Nucl. Med. Technol. 35</I>(3), 115-28.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000176&pid=S0123-921X201600010001000026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Hu, C.; Youtcheff, J.; Wang, D.; Zhang, X.; Kutay, E. &amp; Thyagarajan, S. (2012). Characterization of Asphalt Mixture Homogeneity Based on X-ray Computed Tomography. <I>Journal of Testing and Evaluation 40</I>(7), 1103-1111.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000178&pid=S0123-921X201600010001000027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Jerjen, I.; Revol, V.; Kottler, C. &amp; Kaufmann, R. (2011). The Benefits and Challenges of Differential Phase Contrast Imaging for Material Science. International Symposium on Digital Industrial Radiology and Computed Tomography ((pp. 1-8). Berl&iacute;n.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000180&pid=S0123-921X201600010001000028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Jian F., (2012). Phase Contrast Computed Tomography, Computed Tomography-Clinical Applications. En: L. Saba (ed.). <I>InTech</I>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000182&pid=S0123-921X201600010001000029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Jian, F.; Bin, L.; Hao, Z.; Xingyu, Z.; Zhenggan Z. &amp; Dongbo, W. (2009). X-Ray Phase-Contrast Imaging Methods for Biological Structures. En: <I>BMEI '09. 2nd International Conference on Biomedical Engineering and Informatics </I>(pp. 1-3). DOI: 10.1109/BMEI.2009.5305651.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000184&pid=S0123-921X201600010001000030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Johnson, T. (2012). Dual-Energy CT: General Principles. <I>AJR. Am. J. Roentgenol 119</I>(5), S3-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000186&pid=S0123-921X201600010001000031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Johnson, T. R. C., Krauss, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D. ... Becker, C. R. (2007). Material differentiation by dual energy CT: initial experience. <I>European Radiology 17</I>(6), 1510-1517.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000188&pid=S0123-921X201600010001000032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Kapadia, A.J.; Sharma, A.C.; Tourassi, G.D.; Bender, J.E.; Howell, C.R.; Crowell, A.S. &amp; Floyd, C.E. (2008). Neutron Stimulated Emission Computed Tomography for Diagnosis of Breast Cancer. <I>IEEE Transactions on Nuclear Science 55</I>(1), 501-509.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000190&pid=S0123-921X201600010001000033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Kaza, R.; Platt, J.; Cohan, R.; Caoili, E.; Al-Hawary, M. &amp; Wasnik, A. (2012). Dual-Energy CT with Single- and Dual-Source Scanners: Current Appli- cations in Evaluating the Genitourinary Tract. <I>Radiographics 32</I>(2), 353-69.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000192&pid=S0123-921X201600010001000034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Ketcham, R.A. &amp; Carlson, W.D. (2001). Acquisition, Optimization and Interpretation of X-Ray Computed Tomographic Imagery: Applications to the Geosciences. <I>Computers &amp; Geosciences 27</I>(4), 381-400.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000194&pid=S0123-921X201600010001000035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Knackstedt, M., Carnerup, A., Golab, A., Sok, R., Young, B., &amp; Riepe, L. (2013). Petrophysical Characterization of Unconventional Reservoir Core At Multiple Scales. <I>Petrophysics 54</I>(3), 216-223.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000196&pid=S0123-921X201600010001000036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Levakhina, Y. (2013). <I>Three-Dimensional Digital Tomosynthesis. Iterative Reconstruction, Artifact Reduction and Alternative Acquisition Geometry</I>. Wiesbaden:<I> </I>Springer Fachmedien Wiesbaden.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000198&pid=S0123-921X201600010001000037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Lewitt, R.M.; Member, S.; Matej, S. &amp; Member, S. (2003). Overview of Methods for Image Reconstruction From Projections in Emission Computed Tomography. <I>Proceedings of the IEEE 91</I>(10), 1588-1611.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000200&pid=S0123-921X201600010001000038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Li, J.; Zhu, P. &amp; Sun, Y. (2012). An Approximate Reconstruction Method for Helical Cone-Beam Differential Phase-Contrast Computed Tomography Images. <I>Physics in Medicine and Biology 57</I>(8), 2347-2356.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000202&pid=S0123-921X201600010001000039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Li, T.T.; Li, H. &amp; Diao, L.H. (2008). Cone-Beam Tomography of Propagation-Based Imaging. <I>Applied Physics Letters</I>, 93, 221114-221114-3.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000204&pid=S0123-921X201600010001000040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Lima, I.; Assis, J.T.; Apoloni, C.R.; Mendonca de Souza, S.M.; Duarte, M. E. &amp; Lopes, R.T. (2009). Non-Destructive Imaging Materials Investigation by Microfocus 3D X-Ray Computed Tomography. <I>IEEE Transactions on Nuclear Science 56</I>(3), 1448-1453.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000206&pid=S0123-921X201600010001000041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Liu, Y.; Member, S.; Fernando, G.P. &amp; Sinusas, A.J. (2006). A New Method for Hot-Spot Quantification of Hybrid SPECT / CT Cardiac Images: Methodology and Preliminary Phantom Validation. <I>IEEE Transactions on Nuclear Science 53</I>(5), 2814-2821.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000208&pid=S0123-921X201600010001000042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Lu, Y., Longman, E., Davis, K. G., Ortega, &Aacute;. J., Grossmann, G., Michaelsen, T. E., ... Harding, S. E. (2006). Crystallohydrodynamics of Protein Assemblies: Combining Sedimentation , Viscometry , and X-Ray Scattering. <I>Biophys J.</I>, <I>91</I>(5), 1688-1697.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000210&pid=S0123-921X201600010001000043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>MacCabe, K.P.; Holmgren, A.D.; Tornai, M.P. &amp; Brady, D.J. (s.f.) (2013). Snapshot 2D Tomography Via Coded Aperture X-Ray Scatter Imaging. <I>Appl. Opt. 52</I>(19), 4582-4589.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000212&pid=S0123-921X201600010001000044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Maire, E. &amp; Withers, P.J. (2014). Quantitative X-ray tomography. <I>Int. Mater. Rev.59</I>(1), 1-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000214&pid=S0123-921X201600010001000045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Malcolm, A.A.; Liu, T.; Ng, I.K. &amp; Teng, W.Y. (2013). <I>A Large Scale Multiple Source X-ray CT System for Aerospace Applications</I>. International Symposium on NDT in Aerospace. Singapore.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000216&pid=S0123-921X201600010001000046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Mayo, S.C.,; Miller, P.R.; Wilkins, S.W.; Davis, T.J.; Gao, D.; Gureyev, T.E.; Paganin, D.; Parry, D.J.; Pogany, A.; Robb, T. &amp; Stevenson, A.W. (2002). Phase-Contrast X-Ray Projection Microscopy for Materials Characterisation. <I>Mater. Forum</I>, 26, 15-19.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000218&pid=S0123-921X201600010001000047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Niemi, E.; Lassas M. &amp; Siltanen, S. (2013). Dynamic X-ray tomography with multiple sources. 2013 8th International Symposium on Image and Signal Processing and Analysis (ISPA) (pp.618-621). DOI: 10.1109/ISPA.2013.6703813.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000220&pid=S0123-921X201600010001000048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Ning, R.; Chen, B.; Yu, R.; Conover, D.; Tang, X. &amp; Ning, Y. (2000). Flat Panel Detector-Based Cone-Beam Volume CT Angiography Imaging: System Evaluation. <I>IEEE Transactions on Medical Imaging 19</I>(9), 949-63.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000222&pid=S0123-921X201600010001000049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Pani, S., Cook, E. J., Horrocks, J. A, Jones, J. L., &amp; Speller, R. D. (2010). Characterization of breast tissue using energy-dispersive X-ray diffraction computed tomography. <I>Applied Radiation and Isotopes: Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine</I>, <I>68</I>(10), 1980-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000224&pid=S0123-921X201600010001000050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Prince, J.L. &amp; Links, J. (2005). <I>Medical Imaging Signals and Systems</I>. 2a. ed. Prentice-Hall, Springer.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000226&pid=S0123-921X201600010001000051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Revol, V.; Kottler, C.; Kaufmann, R.; Straumann, U. &amp; Urban, C. (2010). Noise Analysis of Grating-Based X Ray Differential Phase Contrast Imaging. <I>The Review of Scientific Instruments 81</I>(7), 073709-073709-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000228&pid=S0123-921X201600010001000052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Riepe, L. &amp; Suhaimi, M. (2011). Application of High Resolution Micro-CT-Imaging and Pore Network Modeling (PNM) for the Petrophysical Characterization of Tight Gas Reservoirs-A Case History. En: <I>In SPE Middle East Unconventional Gas Conference and Exhibition </I>(pp. 1-13)<I>.</I> Muscat, Oman. DOI: <a href="http://dx.doi.org/10.2118/142472-MS" target="_blank">http://dx.doi.org/10.2118/142472-MS</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000230&pid=S0123-921X201600010001000053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Russo, P.; Lauria, A.; Mettivier, G. &amp; Montesi, M.C. (2008). X ray cone-beam breast computed tomography: Phantom studies. En: <I>2008 IEEE Nucl. Sci. Symp. Conf. Rec.</I>, 4803-4810. DOI: 10.1109/NSSMIC.2008.4774317.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000232&pid=S0123-921X201600010001000054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Schlomka, J., Harding, A., Harding, G., Stevendaal, U. Van, &amp; Grass, M. (2003). Coherent Scatter X-ray Computed Tomography In Medical Applications. <I>IEEE Nuclear Science</I>, <I>2</I>, 900-901.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000234&pid=S0123-921X201600010001000055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><P>Seeram, E. (2008). <I>Computed tomography: Physical Principles, Clinical Applications, and Quality Control. </I>3a. ed. Elsevier Health Sciences<I>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000236&pid=S0123-921X201600010001000056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></I></p>      <!-- ref --><P>Sevak, M.M.; Thakkar, F.N.; Kher, R.K. &amp; Modi, C.K. (2012). CT Image Compression Using Compressive Sensing and Wavelet Transform. In <I>International Conference on Communication Systems and Network Technologies,</I> 138-142, DOI: 10.1109/CSNT.2012.39.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000238&pid=S0123-921X201600010001000057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Shannon, C.E. (1998). Communication in the Presence of Noise. <I>Proceedings of the IEEE 86</I>(2), 447-457.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000240&pid=S0123-921X201600010001000058&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Shefer, E.; Altman, A.; Behling, R.; Goshen, R.; Gregorian, L.; Roterman, Y. &amp; Zarchin, O. (2013). State of the Art of CT Detectors and Sources: A Literature Review. <I>Current Radiology Reports 1</I>(1), 76-91.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000242&pid=S0123-921X201600010001000059&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Su, P.; Yang, J.; Lu, K.; Yu, N.; Wong, S.T.; Xue, Z. &amp; Member, S. (2013). A Fast CT and CT-Fluoroscopy Registration Algorithm With Respiratory Motion Compensation for Image-Guided Lung Intervention. <I>IEEE Transactions on Biomedical Engineering 60</I>(7), 2034-2041.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000244&pid=S0123-921X201600010001000060&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Taina, I.A.; Heck, R.J.; Deen, W. &amp; Ma, E.Y.T. (2013). Quantification of Freeze-Thaw Related Structure in Cultivated Topsoils Using X-Ray Computer Tomography. <I>Canadian Journal of Soil Science 93</I>(4), 533-553.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000246&pid=S0123-921X201600010001000061&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>UGCT (2015). <I>Centre for X-ray Tomography of the Ghent University (UGCT)</I>. Recuperado de: <a href="http://www.ugct.ugent.be" target="_blank">http://www.ugct.ugent.be</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000248&pid=S0123-921X201600010001000062&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Uriondo, O.; Garc, L.; Deustotech-life, Z. &amp; Avda, D. (2011). Computed Tomography CAD System for Monitoring and Modeling the Evolution of Lung Cancer Nodule. <I>IEEE International Symposium on Signal Processing and Information Technology</I>, 484-489. DOI: 10.1109/ISSPIT.2011.6151610.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000250&pid=S0123-921X201600010001000063&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Vine, D.J.; Paganin, D.M.; Pavlov, K.M.; Kr&auml;u&szlig;lich, J.; Wehrhan, O.; Uschmann, I. &amp; F&ouml;rster, E. (2007). Analyzer-Based Phase Contrast Imaging and Phase Retrieval Using a Rotating Anode X-Ray Source. <I>Applied Physics Letters 91</I>(25), 254110-254113.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000252&pid=S0123-921X201600010001000064&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Vontobel, P.; Lehmann, E. &amp; Carlson, W.D. (2005). Comparison of X-Ray and Neutron Tomography Investigations of Geological Materials. <I>IEEE Transactions on Nuclear Science 52</I>(1), 338-341.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000254&pid=S0123-921X201600010001000065&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Wakin, M.B. (2008). An Introduction to Compressive Sampling. <I>IEEE Signal Processing Magazine 25</I>(2), 21-30.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000256&pid=S0123-921X201600010001000066&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Wang G., Yu H. &amp; De Man, B. (2008). An Outlook on X-Ray CT Research and Development. <I>Med. Phys. 35</I>(3), 1051-1063.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000258&pid=S0123-921X201600010001000067&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Webb, S. (1987). A Review of Physical Aspects of X-Ray transmission Computed Tomography. <I>IEEE Proc. A Phys. Sci. Meas. Instrumentation, Manag. Educ. Rev. 134</I>(2), 126-135.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000260&pid=S0123-921X201600010001000068&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Westmore M.S. &amp; F'enster, A., C.I.A. (1995). Investigation of Coherent-Scatter Computed Tomography. <I>Physics of Medical Imaging</I>, 2432, 24-32.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000262&pid=S0123-921X201600010001000069&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Westmore, M.S.; Fenster, A. &amp; Cunningham, I.A. (1997). Tomographic Imaging of the Angular-Dependent Coherent-Scatter Cross Section. <I>Medical Physics</I>, 24, 3-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000264&pid=S0123-921X201600010001000070&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Ying, Z.; Naidu, R. &amp; Crawford, C.R. (2006). Dual Energy Computed Tomography for Explosive Detection. <I>Journal of X-Ray Science and Technology</I>, 14, 235-256.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000266&pid=S0123-921X201600010001000071&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Yoneyama, A.; Yamada, S. &amp; Takeda, T. (2011). Fine Biomedical Imaging Using X-Ray Phase-Sensitive Technique. Advanced Biomedical Engineering. En: G. Gargiulo (ed.). <I>InTech</I>. DOI: 10.5772/20456.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000268&pid=S0123-921X201600010001000072&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Yu, H. &amp; Wang, G. (2009). Compressed sensing based interior tomography. <I>Physics in Medicine and Biology 54</I>(9), 2791-2805.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000270&pid=S0123-921X201600010001000073&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Yuasa, T.; Akiba, M.; Takeda, T.; Kazama, M.; Hoshino, A. &amp; Watanabe, Y. (2002). Incoherent-Scatter Computed Tomography with Monochromatic Synchrotron X Ray: Feasibility of Multi-CT Imaging System for Simultaneous Measurement of Fluorescent and Incoherent Scatter X Rays. <I>IEEE Transactions on Nuclear Science 44</I>(5), 1760-1769.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000272&pid=S0123-921X201600010001000074&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Zhang, R.; Member, S.; Thibault, J.; Bouman, C.A.; Sauer, K.D.; Hsieh, J. &amp; Member, S. (2013). Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model. <I>IEEE Transactions on Medical Imaging 33</I>(1), 117-134.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000274&pid=S0123-921X201600010001000075&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>Zhu, Z.; Wahid, K.A. &amp; Babyn, P. (2012). CT Image Reconstruction from Partial Angular Measurements Via Compressed Sensing. En: <I>IEEE Canadian Conference on Electrical &amp; Computer Engineering</I> (pp. 3-6). DOI: 10.1109/CCECE.2012.6334926.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000276&pid=S0123-921X201600010001000076&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>  </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alpuche]]></surname>
<given-names><![CDATA[J.E]]></given-names>
</name>
<name>
<surname><![CDATA[Pistorius]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Elbakri]]></surname>
<given-names><![CDATA[I.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Novel Hybrid Reconstruction Algorithm for First Generation Incoherent Scatter CT (ISCT) of Large Objects with Potential Medical Imaging Applications]]></article-title>
<source><![CDATA[Journal of X-Ray Science and Technology]]></source>
<year>2011</year>
<volume>19</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>35-56</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<collab>Astra Tomography Toolbox</collab>
<source><![CDATA[A High-Performance GPU MATLAB Toolbox for 2D and 3D Tomography]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barroso]]></surname>
<given-names><![CDATA[R.C]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[R.T]]></given-names>
</name>
<name>
<surname><![CDATA[De Jesus]]></surname>
<given-names><![CDATA[E.F.O]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[L.F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[X-Ray diffraction Microtomography Using Synchrotron Radiation]]></article-title>
<source><![CDATA[Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment]]></source>
<year>2001</year>
<volume>471</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>75-79</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barroso]]></surname>
<given-names><![CDATA[R.C]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[R.T]]></given-names>
</name>
<name>
<surname><![CDATA[Jesus]]></surname>
<given-names><![CDATA[E.F.O]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[L.F]]></given-names>
</name>
<name>
<surname><![CDATA[Description]]></surname>
<given-names><![CDATA[A.B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Synchrotron Biomedical Applications Using X-Ray Diffraction Tomography]]></article-title>
<source><![CDATA[IEEE Conference Record, Nuclear Science Symposium]]></source>
<year>2000</year>
<volume>2</volume>
<page-range>855-859</page-range><publisher-loc><![CDATA[Seattle^eWA WA]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beath]]></surname>
<given-names><![CDATA[S.R]]></given-names>
</name>
<name>
<surname><![CDATA[Cunningham]]></surname>
<given-names><![CDATA[I.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pseudo-Monoenergetic X-Ray Diffraction Measurements Using Balanced Filters for Coherent-Scatter Computed Tomography]]></article-title>
<source><![CDATA[Medical Physics]]></source>
<year>2009</year>
<volume>36</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1839-1847</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bernardi]]></surname>
<given-names><![CDATA[R.T]]></given-names>
</name>
<name>
<surname><![CDATA[Martz]]></surname>
<given-names><![CDATA[H. E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nuclear Waste Drum Characterization with 2 MeV X-Ray and Gamma-Ray Tomography]]></article-title>
<source><![CDATA[Proc. SPIE 2519, X-Ray and Ultraviolet Sensors and Applications]]></source>
<year>1995</year>
<volume>140</volume>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bharkhada]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[H.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Line-source based X-ray tomography]]></article-title>
<source><![CDATA[International Journal of Biomedical Imaging]]></source>
<year>2009</year>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bronnikov]]></surname>
<given-names><![CDATA[A.V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Phase-Contrast CT: Fundamental Theorem and Fast Image Reconstruction Algorithms]]></article-title>
<source><![CDATA[SPIE, Developments in X-Ray Tomography]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buzug]]></surname>
<given-names><![CDATA[T.M]]></given-names>
</name>
</person-group>
<source><![CDATA[Computed Tomography: From Photon Statistics to Modern Cone-Beam CT]]></source>
<year>2007</year>
<publisher-loc><![CDATA[Berlín ]]></publisher-loc>
<publisher-name><![CDATA[Heidelberg: Springer Verlag]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Candes]]></surname>
<given-names><![CDATA[E.J]]></given-names>
</name>
<name>
<surname><![CDATA[Tao]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?]]></article-title>
<source><![CDATA[IEEE Transactions on Information Theory]]></source>
<year>2006</year>
<volume>52</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>5406-5425</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Candès]]></surname>
<given-names><![CDATA[E.J]]></given-names>
</name>
<name>
<surname><![CDATA[Romberg]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tao]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Robust Uncertainty Principles: Exact Signal Reconstruction From Highly Incomplete Frequency Information]]></article-title>
<source><![CDATA[IEEE Transactions on Information Theory]]></source>
<year>2006</year>
<volume>52</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>489-509</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Changizi]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Oghabian]]></surname>
<given-names><![CDATA[M. A]]></given-names>
</name>
<name>
<surname><![CDATA[Speller]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Sarkar]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kheradmand]]></surname>
<given-names><![CDATA[A. A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of Small Angle X-ray Scattering (SAXS) for Differentiation between Normal and Cancerous Breast Tissue]]></article-title>
<source><![CDATA[Int J Med Sci]]></source>
<year>2005</year>
<volume>2</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>118-121</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Cong]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Vese]]></surname>
<given-names><![CDATA[L.A]]></given-names>
</name>
<name>
<surname><![CDATA[Villasenor]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Hybrid Architecture for Compressive Sensing 3-D CT Reconstruction]]></article-title>
<source><![CDATA[IEEE Journal on Emerging and Selected Topics in Circuits and Systems]]></source>
<year>2012</year>
<volume>2</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>616-625</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[M.K]]></given-names>
</name>
<name>
<surname><![CDATA[Youn]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Jang]]></surname>
<given-names><![CDATA[S.Y]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[M.C]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[H.K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Digital Tomosynthesis in Cone-Beam Geometry for Industrial Applications: Feasibility and Preliminary Study]]></article-title>
<source><![CDATA[International Journal of Precision Engineering and Manufacturing]]></source>
<year>2012</year>
<volume>13</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1533-1538</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Brady]]></surname>
<given-names><![CDATA[D.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coded Aperture Computed Tomography]]></article-title>
<source><![CDATA[Proc. SPIE 7468, Adaptive Coded Aperture Imaging, Non-Imaging, and Unconventional Imaging Sensor Systems]]></source>
<year>2009</year>
<page-range>74680</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chong]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Essue]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Innovations in Cardiac Computed Tomography: Cone Beam CT/Volume CT and Dual Source CT]]></article-title>
<source><![CDATA[UWOMJ]]></source>
<year>2008</year>
<volume>77</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>6-11</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cong]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[X-Ray Scattering Tomography for Biological Applications]]></article-title>
<source><![CDATA[J. Xray. Sci. Technol]]></source>
<year>2011</year>
<volume>19</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>219-227</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Darshini]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Karandharaj]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Medical image processing schemes for cancer detection: A survey]]></source>
<year>2014</year>
<conf-name><![CDATA[ International Conference on Green Computing Communication and Electrical Engineering]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-6</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dobbins]]></surname>
<given-names><![CDATA[J.T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tomosynthesis Imaging: At a Translational Crossroads]]></article-title>
<source><![CDATA[Medical Physics]]></source>
<year>2009</year>
<volume>36</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1956--1967</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Donoho]]></surname>
<given-names><![CDATA[D.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Compressed Sensing]]></article-title>
<source><![CDATA[IEEE Transactions on Information Theory]]></source>
<year>2006</year>
<volume>52</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1289-1306</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Galvis]]></surname>
<given-names><![CDATA[D.F]]></given-names>
</name>
<name>
<surname><![CDATA[Mejía]]></surname>
<given-names><![CDATA[Y.H]]></given-names>
</name>
<name>
<surname><![CDATA[Argüello]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Efficient Reconstruction of Raman Spectroscopy Imaging Based on Compressive Sensing]]></article-title>
<source><![CDATA[DYNA]]></source>
<year>2014</year>
<volume>81</volume>
<numero>118</numero>
<issue>118</issue>
<page-range>116-124</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gang]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ji]]></surname>
<given-names><![CDATA[F.D]]></given-names>
</name>
</person-group>
<source><![CDATA[The Research & Application of the Detection Capability of Dangerous Goods in Dual-Energy X-Ray Security Equipment]]></source>
<year>2009</year>
<volume>2</volume>
<conf-name><![CDATA[ IEEE International Conference on Intelligent Computation Technology and Automation]]></conf-name>
<conf-loc> </conf-loc>
<page-range>352-355</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gehrke]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wirth]]></surname>
<given-names><![CDATA[K.E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of Conventional- and Dual-Energy X-Ray Tomography in Process Engineering]]></article-title>
<source><![CDATA[IEEE Sens. J]]></source>
<year>2005</year>
<volume>5</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>183-187</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Geng]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Volumetric 3D Display for Radiation Therapy Planning]]></article-title>
<source><![CDATA[Journal of Display Technology]]></source>
<year>2008</year>
<volume>4</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>437-450</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghonge]]></surname>
<given-names><![CDATA[N.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computed Tomography in the 21st Century: Current Status & Future Prospects]]></article-title>
<source><![CDATA[JIMSA]]></source>
<year>2013</year>
<volume>26</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>35-42</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldman]]></surname>
<given-names><![CDATA[L.W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Principles of CT and CT Technology]]></article-title>
<source><![CDATA[J. Nucl. Med. Technol]]></source>
<year>2007</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>115-28</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Youtcheff]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Kutay]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Thyagarajan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of Asphalt Mixture Homogeneity Based on X-ray Computed Tomography]]></article-title>
<source><![CDATA[Journal of Testing and Evaluation]]></source>
<year>2012</year>
<volume>40</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1103-1111</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jerjen]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Revol]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Kottler]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufmann]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[The Benefits and Challenges of Differential Phase Contrast Imaging for Material Science]]></source>
<year>2011</year>
<conf-name><![CDATA[ International Symposium on Digital Industrial Radiology and Computed Tomography]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-8</page-range><publisher-loc><![CDATA[Berlín ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jian]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Saba]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<source><![CDATA[Phase Contrast Computed Tomography, Computed Tomography-Clinical Applications]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jian]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Bin]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hao]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Xingyu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Zhenggan]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Dongbo]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<source><![CDATA[X-Ray Phase-Contrast Imaging Methods for Biological Structures]]></source>
<year>2009</year>
<conf-name><![CDATA[ BMEI '09. 2nd International Conference on Biomedical Engineering and Informatics]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-3</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dual-Energy CT: General Principles]]></article-title>
<source><![CDATA[AJR. Am. J. Roentgenol]]></source>
<year>2012</year>
<volume>119</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>S3-8</page-range></nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Krauss]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Sedlmair]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grasruck]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bruder]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Morhard]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Becker]]></surname>
<given-names><![CDATA[C. R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Material differentiation by dual energy CT: initial experience]]></article-title>
<source><![CDATA[European Radiology]]></source>
<year>2007</year>
<volume>17</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1510-1517</page-range></nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kapadia]]></surname>
<given-names><![CDATA[A.J]]></given-names>
</name>
<name>
<surname><![CDATA[Sharma]]></surname>
<given-names><![CDATA[A.C]]></given-names>
</name>
<name>
<surname><![CDATA[Tourassi]]></surname>
<given-names><![CDATA[G.D]]></given-names>
</name>
<name>
<surname><![CDATA[Bender]]></surname>
<given-names><![CDATA[J.E]]></given-names>
</name>
<name>
<surname><![CDATA[Howell]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
<name>
<surname><![CDATA[Crowell]]></surname>
<given-names><![CDATA[A.S]]></given-names>
</name>
<name>
<surname><![CDATA[Floyd]]></surname>
<given-names><![CDATA[C.E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neutron Stimulated Emission Computed Tomography for Diagnosis of Breast Cancer]]></article-title>
<source><![CDATA[IEEE Transactions on Nuclear Science]]></source>
<year>2008</year>
<volume>55</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>501-509</page-range></nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaza]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Platt]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cohan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Caoili]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Hawary]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wasnik]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dual-Energy CT with Single- and Dual-Source Scanners: Current Appli- cations in Evaluating the Genitourinary Tract]]></article-title>
<source><![CDATA[Radiographics]]></source>
<year>2012</year>
<volume>32</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>353-69</page-range></nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ketcham]]></surname>
<given-names><![CDATA[R.A]]></given-names>
</name>
<name>
<surname><![CDATA[Carlson]]></surname>
<given-names><![CDATA[W.D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Acquisition, Optimization and Interpretation of X-Ray Computed Tomographic Imagery: Applications to the Geosciences]]></article-title>
<source><![CDATA[Computers & Geosciences]]></source>
<year>2001</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>381-400</page-range></nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Knackstedt]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Carnerup]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Golab]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sok]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Young]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Riepe]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Petrophysical Characterization of Unconventional Reservoir Core At Multiple Scales]]></article-title>
<source><![CDATA[Petrophysics]]></source>
<year>2013</year>
<volume>54</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>216-223</page-range></nlm-citation>
</ref>
<ref id="B37">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Levakhina]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Three-Dimensional Digital Tomosynthesis. Iterative Reconstruction, Artifact Reduction and Alternative Acquisition Geometry]]></source>
<year>2013</year>
<publisher-loc><![CDATA[Wiesbaden ]]></publisher-loc>
<publisher-name><![CDATA[Springer Fachmedien Wiesbaden]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B38">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lewitt]]></surname>
<given-names><![CDATA[R.M]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Matej]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Overview of Methods for Image Reconstruction From Projections in Emission Computed Tomography]]></article-title>
<source><![CDATA[Proceedings of the IEEE]]></source>
<year>2003</year>
<volume>91</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1588-1611</page-range></nlm-citation>
</ref>
<ref id="B39">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Sun]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Approximate Reconstruction Method for Helical Cone-Beam Differential Phase-Contrast Computed Tomography Images]]></article-title>
<source><![CDATA[Physics in Medicine and Biology]]></source>
<year>2012</year>
<volume>57</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>2347-2356</page-range></nlm-citation>
</ref>
<ref id="B40">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[T.T]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Diao]]></surname>
<given-names><![CDATA[L.H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cone-Beam Tomography of Propagation-Based Imaging]]></article-title>
<source><![CDATA[Applied Physics Letters]]></source>
<year>2008</year>
<volume>93</volume>
<page-range>221114-221114-3</page-range></nlm-citation>
</ref>
<ref id="B41">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Assis]]></surname>
<given-names><![CDATA[J.T]]></given-names>
</name>
<name>
<surname><![CDATA[Apoloni]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
<name>
<surname><![CDATA[Mendonca de Souza]]></surname>
<given-names><![CDATA[S.M]]></given-names>
</name>
<name>
<surname><![CDATA[Duarte]]></surname>
<given-names><![CDATA[M. E]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[R.T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Non-Destructive Imaging Materials Investigation by Microfocus 3D X-Ray Computed Tomography]]></article-title>
<source><![CDATA[IEEE Transactions on Nuclear Science]]></source>
<year>2009</year>
<volume>56</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1448-1453</page-range></nlm-citation>
</ref>
<ref id="B42">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fernando]]></surname>
<given-names><![CDATA[G.P]]></given-names>
</name>
<name>
<surname><![CDATA[Sinusas]]></surname>
<given-names><![CDATA[A.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A New Method for Hot-Spot Quantification of Hybrid SPECT / CT Cardiac Images: Methodology and Preliminary Phantom Validation]]></article-title>
<source><![CDATA[IEEE Transactions on Nuclear Science]]></source>
<year>2006</year>
<volume>53</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>2814-2821</page-range></nlm-citation>
</ref>
<ref id="B43">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Longman]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Davis]]></surname>
<given-names><![CDATA[K. G]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[Á. J]]></given-names>
</name>
<name>
<surname><![CDATA[Grossmann]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Michaelsen]]></surname>
<given-names><![CDATA[T. E]]></given-names>
</name>
<name>
<surname><![CDATA[Harding]]></surname>
<given-names><![CDATA[S. E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Crystallohydrodynamics of Protein Assemblies: Combining Sedimentation , Viscometry , and X-Ray Scattering]]></article-title>
<source><![CDATA[Biophys J]]></source>
<year>2006</year>
<volume>91</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1688-1697</page-range></nlm-citation>
</ref>
<ref id="B44">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MacCabe]]></surname>
<given-names><![CDATA[K.P]]></given-names>
</name>
<name>
<surname><![CDATA[Holmgren]]></surname>
<given-names><![CDATA[A.D]]></given-names>
</name>
<name>
<surname><![CDATA[Tornai]]></surname>
<given-names><![CDATA[M.P]]></given-names>
</name>
<name>
<surname><![CDATA[Brady]]></surname>
<given-names><![CDATA[D.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Snapshot 2D Tomography Via Coded Aperture X-Ray Scatter Imaging]]></article-title>
<source><![CDATA[Appl. Opt]]></source>
<year>2013</year>
<volume>52</volume>
<numero>19</numero>
<issue>19</issue>
<page-range>4582-4589</page-range></nlm-citation>
</ref>
<ref id="B45">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maire]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Withers]]></surname>
<given-names><![CDATA[P.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantitative X-ray tomography]]></article-title>
<source><![CDATA[Int. Mater. Rev]]></source>
<year>2014</year>
<volume>59</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1-43</page-range></nlm-citation>
</ref>
<ref id="B46">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Malcolm]]></surname>
<given-names><![CDATA[A.A]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ng]]></surname>
<given-names><![CDATA[I.K]]></given-names>
</name>
<name>
<surname><![CDATA[Teng]]></surname>
<given-names><![CDATA[W.Y]]></given-names>
</name>
</person-group>
<source><![CDATA[A Large Scale Multiple Source X-ray CT System for Aerospace Applications]]></source>
<year>2013</year>
<conf-name><![CDATA[ International Symposium on NDT in Aerospace]]></conf-name>
<conf-loc> </conf-loc>
<publisher-loc><![CDATA[Singapore ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B47">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mayo]]></surname>
<given-names><![CDATA[S.C]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[P.R]]></given-names>
</name>
<name>
<surname><![CDATA[Wilkins]]></surname>
<given-names><![CDATA[S.W]]></given-names>
</name>
<name>
<surname><![CDATA[Davis]]></surname>
<given-names><![CDATA[T.J]]></given-names>
</name>
<name>
<surname><![CDATA[Gao]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gureyev]]></surname>
<given-names><![CDATA[T.E]]></given-names>
</name>
<name>
<surname><![CDATA[Paganin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Parry]]></surname>
<given-names><![CDATA[D.J]]></given-names>
</name>
<name>
<surname><![CDATA[Pogany]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Robb]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Stevenson]]></surname>
<given-names><![CDATA[A.W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Phase-Contrast X-Ray Projection Microscopy for Materials Characterisation]]></article-title>
<source><![CDATA[Mater. Forum]]></source>
<year>2002</year>
<volume>26</volume>
<page-range>15-19</page-range></nlm-citation>
</ref>
<ref id="B48">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Niemi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Lassas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Siltanen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Dynamic X-ray tomography with multiple sources]]></source>
<year>2013</year>
<conf-name><![CDATA[ 2013 8th International Symposium on Image and Signal Processing and Analysis]]></conf-name>
<conf-loc> </conf-loc>
<page-range>618-621</page-range><publisher-name><![CDATA[ISPA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B49">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ning]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Conover]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Ning]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flat Panel Detector-Based Cone-Beam Volume CT Angiography Imaging: System Evaluation]]></article-title>
<source><![CDATA[IEEE Transactions on Medical Imaging]]></source>
<year>2000</year>
<volume>19</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>949-63</page-range></nlm-citation>
</ref>
<ref id="B50">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pani]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[E. J]]></given-names>
</name>
<name>
<surname><![CDATA[Horrocks]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jones]]></surname>
<given-names><![CDATA[J. L]]></given-names>
</name>
<name>
<surname><![CDATA[Speller]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of breast tissue using energy-dispersive X-ray diffraction computed tomography]]></article-title>
<source><![CDATA[Applied Radiation and Isotopes: Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine]]></source>
<year>2010</year>
<volume>68</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1980-7</page-range></nlm-citation>
</ref>
<ref id="B51">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Prince]]></surname>
<given-names><![CDATA[J.L]]></given-names>
</name>
<name>
<surname><![CDATA[Links]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Medical Imaging Signals and Systems]]></source>
<year>2005</year>
<edition>2</edition>
<publisher-loc><![CDATA[Springer ]]></publisher-loc>
<publisher-name><![CDATA[Prentice-Hall]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B52">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Revol]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Kottler]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufmann]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Straumann]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Urban]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise Analysis of Grating-Based X Ray Differential Phase Contrast Imaging]]></article-title>
<source><![CDATA[The Review of Scientific Instruments]]></source>
<year>2010</year>
<volume>81</volume>
<numero>7</numero>
<issue>7</issue>
</nlm-citation>
</ref>
<ref id="B53">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Riepe]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Suhaimi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Application of High Resolution Micro-CT-Imaging and Pore Network Modeling (PNM) for the Petrophysical Characterization of Tight Gas Reservoirs-A Case History]]></source>
<year>2011</year>
<conf-name><![CDATA[ In SPE Middle East Unconventional Gas Conference and Exhibition]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-13</page-range><publisher-loc><![CDATA[Muscat ]]></publisher-loc>
<publisher-name><![CDATA[Oman]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B54">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Russo]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lauria]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mettivier]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Montesi]]></surname>
<given-names><![CDATA[M.C]]></given-names>
</name>
</person-group>
<source><![CDATA[X ray cone-beam breast computed tomography: Phantom studies]]></source>
<year>2008</year>
<conf-name><![CDATA[ IEEE Nucl. Sci. Symp. Conf. Rec]]></conf-name>
<conf-date>2008</conf-date>
<conf-loc> </conf-loc>
<page-range>4803-4810</page-range></nlm-citation>
</ref>
<ref id="B55">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schlomka]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Harding]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Harding]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Stevendaal]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Grass]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coherent Scatter X-ray Computed Tomography In Medical Applications]]></article-title>
<source><![CDATA[IEEE Nuclear Science]]></source>
<year>2003</year>
<volume>2</volume>
<page-range>900-901</page-range></nlm-citation>
</ref>
<ref id="B56">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Seeram]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Computed tomography: Physical Principles, Clinical Applications, and Quality Control]]></source>
<year>2008</year>
<edition>3</edition>
<publisher-name><![CDATA[Elsevier Health Sciences]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B57">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sevak]]></surname>
<given-names><![CDATA[M.M]]></given-names>
</name>
<name>
<surname><![CDATA[Thakkar]]></surname>
<given-names><![CDATA[F.N]]></given-names>
</name>
<name>
<surname><![CDATA[Kher]]></surname>
<given-names><![CDATA[R.K]]></given-names>
</name>
<name>
<surname><![CDATA[Modi]]></surname>
<given-names><![CDATA[C.K]]></given-names>
</name>
</person-group>
<source><![CDATA[CT Image Compression Using Compressive Sensing and Wavelet Transform]]></source>
<year>2012</year>
<conf-name><![CDATA[ International Conference on Communication Systems and Network Technologies]]></conf-name>
<conf-loc> </conf-loc>
<page-range>138-142</page-range></nlm-citation>
</ref>
<ref id="B58">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shannon]]></surname>
<given-names><![CDATA[C.E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Communication in the Presence of Noise]]></article-title>
<source><![CDATA[Proceedings of the IEEE]]></source>
<year>1998</year>
<volume>86</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>447-457</page-range></nlm-citation>
</ref>
<ref id="B59">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shefer]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Altman]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Behling]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Goshen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gregorian]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Roterman]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zarchin]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[State of the Art of CT Detectors and Sources: A Literature Review]]></article-title>
<source><![CDATA[Current Radiology Reports]]></source>
<year>2013</year>
<volume>1</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>76-91</page-range></nlm-citation>
</ref>
<ref id="B60">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[S.T]]></given-names>
</name>
<name>
<surname><![CDATA[Xue]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Fast CT and CT-Fluoroscopy Registration Algorithm With Respiratory Motion Compensation for Image-Guided Lung Intervention]]></article-title>
<source><![CDATA[IEEE Transactions on Biomedical Engineering]]></source>
<year>2013</year>
<volume>60</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>2034-2041</page-range></nlm-citation>
</ref>
<ref id="B61">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Taina]]></surname>
<given-names><![CDATA[I.A]]></given-names>
</name>
<name>
<surname><![CDATA[Heck]]></surname>
<given-names><![CDATA[R.J]]></given-names>
</name>
<name>
<surname><![CDATA[Deen]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[E.Y.T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantification of Freeze-Thaw Related Structure in Cultivated Topsoils Using X-Ray Computer Tomography]]></article-title>
<source><![CDATA[Canadian Journal of Soil Science]]></source>
<year>2013</year>
<volume>93</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>533-553</page-range></nlm-citation>
</ref>
<ref id="B62">
<nlm-citation citation-type="">
<collab>UGCT</collab>
<source><![CDATA[Centre for X-ray Tomography of the Ghent University (UGCT)]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B63">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Uriondo]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Garc]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Deustotech-life]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Avda]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computed Tomography CAD System for Monitoring and Modeling the Evolution of Lung Cancer Nodule]]></article-title>
<source><![CDATA[EEE International Symposium on Signal Processing and Information Technology]]></source>
<year>2011</year>
<page-range>484-489</page-range></nlm-citation>
</ref>
<ref id="B64">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vine]]></surname>
<given-names><![CDATA[D.J]]></given-names>
</name>
<name>
<surname><![CDATA[Paganin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Pavlov]]></surname>
<given-names><![CDATA[K.M]]></given-names>
</name>
<name>
<surname><![CDATA[Kräußlich]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wehrhan]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Uschmann]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Förster]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analyzer-Based Phase Contrast Imaging and Phase Retrieval Using a Rotating Anode X-Ray Source]]></article-title>
<source><![CDATA[Applied Physics Letters]]></source>
<year>2007</year>
<volume>91</volume>
<numero>25</numero>
<issue>25</issue>
<page-range>254110-254113</page-range></nlm-citation>
</ref>
<ref id="B65">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vontobel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lehmann]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Carlson]]></surname>
<given-names><![CDATA[W.D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of X-Ray and Neutron Tomography Investigations of Geological Materials]]></article-title>
<source><![CDATA[IEEE Transactions on Nuclear Science]]></source>
<year>2005</year>
<volume>52</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>338-341</page-range></nlm-citation>
</ref>
<ref id="B66">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wakin]]></surname>
<given-names><![CDATA[M.B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Introduction to Compressive Sampling]]></article-title>
<source><![CDATA[IEEE Signal Processing Magazine]]></source>
<year>2008</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>21-30</page-range></nlm-citation>
</ref>
<ref id="B67">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[De Man]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Outlook on X-Ray CT Research and Development]]></article-title>
<source><![CDATA[Med. Phys]]></source>
<year>2008</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1051-1063</page-range></nlm-citation>
</ref>
<ref id="B68">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Webb]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Review of Physical Aspects of X-Ray transmission Computed Tomography]]></article-title>
<source><![CDATA[IEEE Proc. A Phys. Sci. Meas. Instrumentation, Manag. Educ. Rev]]></source>
<year>1987</year>
<volume>134</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>126-135</page-range></nlm-citation>
</ref>
<ref id="B69">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Westmore]]></surname>
<given-names><![CDATA[M.S]]></given-names>
</name>
<name>
<surname><![CDATA[F'enster]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Investigation of Coherent-Scatter Computed Tomography]]></article-title>
<source><![CDATA[Physics of Medical Imaging]]></source>
<year>1995</year>
<volume>2432</volume>
<page-range>24-32</page-range></nlm-citation>
</ref>
<ref id="B70">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Westmore]]></surname>
<given-names><![CDATA[M.S]]></given-names>
</name>
<name>
<surname><![CDATA[Fenster]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cunningham]]></surname>
<given-names><![CDATA[I.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tomographic Imaging of the Angular-Dependent Coherent-Scatter Cross Section]]></article-title>
<source><![CDATA[Medical Physics]]></source>
<year>1997</year>
<volume>24</volume>
<page-range>3-10</page-range></nlm-citation>
</ref>
<ref id="B71">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ying]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Naidu]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Crawford]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dual Energy Computed Tomography for Explosive Detection]]></article-title>
<source><![CDATA[Journal of X-Ray Science and Technology]]></source>
<year>2006</year>
<volume>14</volume>
<page-range>235-256</page-range></nlm-citation>
</ref>
<ref id="B72">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yoneyama]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yamada]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Takeda]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fine Biomedical Imaging Using X-Ray Phase-Sensitive Technique. Advanced Biomedical Engineering]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Gargiulo]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[InTech]]></source>
<year>2011</year>
</nlm-citation>
</ref>
<ref id="B73">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Compressed sensing based interior tomography]]></article-title>
<source><![CDATA[Physics in Medicine and Biology]]></source>
<year>2009</year>
<volume>54</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>2791-2805</page-range></nlm-citation>
</ref>
<ref id="B74">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yuasa]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Akiba]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Takeda]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kazama]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hoshino]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Incoherent-Scatter Computed Tomography with Monochromatic Synchrotron X Ray: Feasibility of Multi-CT Imaging System for Simultaneous Measurement of Fluorescent and Incoherent Scatter X Rays]]></article-title>
<source><![CDATA[IEEE Transactions on Nuclear Science]]></source>
<year>2002</year>
<volume>44</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1760-1769</page-range></nlm-citation>
</ref>
<ref id="B75">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Thibault]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bouman]]></surname>
<given-names><![CDATA[C.A]]></given-names>
</name>
<name>
<surname><![CDATA[Sauer]]></surname>
<given-names><![CDATA[K.D]]></given-names>
</name>
<name>
<surname><![CDATA[Hsieh]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Member]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model]]></article-title>
<source><![CDATA[IEEE Transactions on Medical Imaging]]></source>
<year>2013</year>
<volume>33</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>117-134</page-range></nlm-citation>
</ref>
<ref id="B76">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Wahid]]></surname>
<given-names><![CDATA[K.A]]></given-names>
</name>
<name>
<surname><![CDATA[Babyn]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[CT Image Reconstruction from Partial Angular Measurements Via Compressed Sensing]]></source>
<year>2012</year>
<conf-name><![CDATA[ IEEE Canadian Conference on Electrical & Computer Engineering]]></conf-name>
<conf-loc> </conf-loc>
<page-range>3-6</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>