<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0124-7107</journal-id>
<journal-title><![CDATA[Universidad y Salud]]></journal-title>
<abbrev-journal-title><![CDATA[Univ. Salud]]></abbrev-journal-title>
<issn>0124-7107</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Nariño]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0124-71072015000200002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Nivel de ruido en la unidad de cuidado intensivo adulto: Medición, estándares internacionales e implicancias sanitarias: measurement, international standards and health implications]]></article-title>
<article-title xml:lang="en"><![CDATA[Noise level in the intensive care unit for adults]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Garrido-Galindo]]></surname>
<given-names><![CDATA[Angélica Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Camargo-Caicedo]]></surname>
<given-names><![CDATA[Yiniva]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vélez-Pereira]]></surname>
<given-names><![CDATA[Andrés M.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad del Magdalena  ]]></institution>
<addr-line><![CDATA[Santa Marta ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad del Magdalena  ]]></institution>
<addr-line><![CDATA[Santa Marta ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad del Magdalena  ]]></institution>
<addr-line><![CDATA[Santa Marta ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<volume>17</volume>
<numero>2</numero>
<fpage>163</fpage>
<lpage>169</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0124-71072015000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0124-71072015000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0124-71072015000200002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo: Evaluar el nivel continuo equivalente de ruido en una unidad de cuidado intensivo adulto perteneciente a un hospital de la ciudad de Santa Marta con los niveles sugeridos por los estándares internacionales. Materiales y métodos: Se realizó un muestreo continuo durante 20 días registrando datos cada minuto con un sonómetro tipo I en un eje central de la unidad de cuidado intensivo adulto del hospital; los datos registrados correspondían a los valores máximos, mínimos y el nivel continuo equivalente de ruido en ponderación frecuencial A y el filtro de ponderación temporal Fast. Resultados: Se reporta que el nivel de ruido continuo equivalente varió entre 49-71 dBA con un valor máximo de 91,19 dBA y un mínimo de 46,65 dBA. El análisis de varianza infiere que el valor medio de ruido varía con la hora del día. Conclusiones: El nivel de ruido continuo equivalente presentado en la unidad de cuidado intensivo adulto es consistente con otros estudios similares, no obstante los valores presentados exceden los estándares internacionales de ruido sugeridos, generando una preocupación por los riesgos de exposición a los que se encuentran pacientes y personal médico de la unidad.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Objective: To assess the continuous equivalent noise level in an intensive care unit for adults that belongs to a hospital in the city of Santa Marta using the levels suggested by international standards. Materials and methods: A continuous sampling was done during 20 days where the data was recorded every minute by using a sound level meter type I in a central axis of the intensive care unit for adults in the hospital; the recorded data corresponded to the maximum, minimum values and the equivalent continuous level of noise on frequency weighting A and the Fast time weighting filter. Results: It was reported that the equivalent continuous noise level varied between 49-71 dBA with a maximum value of 91,19 dBA and a minimum of 46,65 dBA. The variance analysis infers that the mean value of noise varies according to the time of day. Conclusions: The level of equivalent continuous noise presented in the intensive care unit for adults is consistent with other similar studies; however, the displayed values exceed the international standards of noise suggested, which generates a concern about the risks of exposure for the patients as well as for the medical staff of the unit.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Monitoreo del ruido]]></kwd>
<kwd lng="es"><![CDATA[salud pública]]></kwd>
<kwd lng="es"><![CDATA[ruido en el ambiente de trabajo]]></kwd>
<kwd lng="es"><![CDATA[cuidados intensivos]]></kwd>
<kwd lng="en"><![CDATA[Noise monitoring]]></kwd>
<kwd lng="en"><![CDATA[public health]]></kwd>
<kwd lng="en"><![CDATA[noise in the Working Environment]]></kwd>
<kwd lng="en"><![CDATA[intensive care]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="verdana">      <p align="center"><font size="4"><b>Nivel de ruido en la unidad de cuidado intensivo adulto: Medici&oacute;n, est&aacute;ndares internacionales e implicancias sanitarias</b></font></p>      <p  align="center"><font size="3">Noise level in the intensive care unit for adults: measurement, international standards and health implications</font></p>    <br>      <p align="center"><b>Ang&eacute;lica Patricia Garrido-Galindo<sup>1</sup>, Yiniva Camargo-Caicedo<sup>2</sup>, Andr&eacute;s M. V&eacute;lez-Pereira<sup>3</sup></b></p>      <p><sup>1</sup> Ing. Ambiental y Sanitaria, Estudiante de Maestr&iacute;a en Ingenier&iacute;a Ambiental. Grupo de Investigaci&oacute;n en Modelaci&oacute;n de Sistemas Ambientales GIMSA, Universidad del Magdalena. Santa Marta, Colombia. e-mail:  <a href="mailto:garridogap@gmail.com">garridogap@gmail.com</a>    <br> <sup>2</sup> Ing. Qu&iacute;mica, M&aacute;ster en Educaci&oacute;n Ambiental. Docente-Investigadora, Grupo de Investigaci&oacute;n en Modelaci&oacute;n de Sistemas Ambientales GIMSA, Universidad del Magdalena. Santa Marta, Colombia. e-mail: <a href="mailto:ycamargo@unimagdalena.edu.co">ycamargo@unimagdalena.edu.co</a>    <br> <sup>3</sup> Ing. Ambiental y Sanitario, Mg. en Tecnolog&iacute;a Ambiental, Estudiante de Doctorado en Ciencia y Tecnolog&iacute;a Ambientales. Grupo de Investigaci&oacute;n en Modelaci&oacute;n de Sistemas Ambientales GIMSA, Universidad del Magdalena. Santa Marta, Colombia. e-mail: <a href="mailto:ing.andresvelez@gmail.com">ing.andresvelez@gmail.com</a></p>      <p>Fecha de recepci&oacute;n: Noviembre 5 - 2014 / Fecha de aceptaci&oacute;n: Septiembre 18 - 2015</p>  <hr size="1">      <p><i>Garrido-Galindo AP, Camargo-Caicedo Y, V&eacute;lez-Pereira AM. Nivel de ruido en la unidad de cuidado intensivo adulto: Medici&oacute;n, est&aacute;ndares internacionales e implicancias sanitarias. Rev Univ. salud. 2015;17(2):163-169.</i></p>  <hr size="1">    ]]></body>
<body><![CDATA[<br>      <p align="center"><font size="3"><b>Resumen</b></font></p>      <p><b>Objetivo</b>: Evaluar el nivel continuo equivalente de ruido en una unidad de cuidado intensivo adulto perteneciente a un hospital de la ciudad de Santa Marta con los niveles sugeridos por los est&aacute;ndares internacionales. <b>Materiales y m&eacute;todos</b>: Se realiz&oacute; un muestreo continuo durante 20 d&iacute;as registrando datos cada minuto con un son&oacute;metro tipo I en un eje central de la unidad de cuidado intensivo adulto del hospital; los datos registrados correspond&iacute;an a los valores m&aacute;ximos, m&iacute;nimos y el nivel continuo equivalente de ruido en ponderaci&oacute;n frecuencial A y el filtro de ponderaci&oacute;n temporal Fast. <b>Resultados</b>: Se reporta que el nivel de ruido continuo equivalente vari&oacute; entre 49-71 dBA con un valor m&aacute;ximo de 91,19 dBA y un m&iacute;nimo de 46,65 dBA. El an&aacute;lisis de varianza infiere que el valor medio de ruido var&iacute;a con la hora del d&iacute;a. <b>Conclusiones</b>: El nivel de ruido continuo equivalente presentado en la unidad de cuidado intensivo adulto es consistente con otros estudios similares, no obstante los valores presentados exceden los est&aacute;ndares internacionales de ruido sugeridos, generando una preocupaci&oacute;n por los riesgos de exposici&oacute;n a los que se encuentran pacientes y personal m&eacute;dico de la unidad.</p>       <p><b>Palabras clave</b>: Monitoreo del ruido, salud p&uacute;blica, ruido en el ambiente de trabajo, cuidados intensivos. (Fuente: DeCS, Bireme).</p>  <hr size="1">    <br>      <p align="center"><font size="3"><b>Abstract</b></font></p>      <p><b>Objective</b>: To assess the continuous equivalent noise level in an intensive care unit for adults that belongs to a hospital in the city of Santa Marta using the levels suggested by international standards. <b>Materials and methods</b>: A continuous sampling was done during 20 days where the data was recorded every minute by using a sound level meter type I in a central axis of the intensive care unit for adults in the hospital; the recorded data corresponded to the maximum, minimum values and the equivalent continuous level of noise on frequency weighting A and the Fast time weighting filter. <b>Results</b>: It was reported that the equivalent continuous noise level varied between 49-71 dBA with a maximum value of 91,19 dBA and a minimum of 46,65 dBA. The variance analysis infers that the mean value of noise varies according to the time of day. <b>Conclusions</b>: The level of equivalent continuous noise presented in the intensive care unit for adults is consistent with other similar studies; however, the displayed values exceed the international standards of noise suggested, which generates a concern about the risks of exposure for the patients as well as for the medical staff of the unit.</p>      <p><b>Keywords</b>: Noise monitoring, public health, noise in the working environment, intensive care. (Source: DeCS, Bireme).</p>  <hr size="1">    <br>      <p align="center"><font size="3"><b>Introducci&oacute;n</b></font></p>      ]]></body>
<body><![CDATA[<p>El ambiente dentro de las unidades de cuidado intensivo (UCI) est&aacute; influenciado por m&uacute;ltiples factores estresantes para los pacientes y para el personal que labora en &eacute;stas. Es as&iacute; como el nivel de ruido se establece como uno de los agentes que deterioran el nivel de confort en la unidad. Los principales efectos sobre los pacientes asociados a la exposici&oacute;n a ruido excesivo dentro de las UCI son el aumento de la frecuencia card&iacute;aca y tensi&oacute;n arterial, la privaci&oacute;n de sue&ntilde;o y alteraciones en la funci&oacute;n inmunol&oacute;gica. Adicionalmente el ruido excesivo incide sobre el bienestar del personal asistencial que labora en la unidad de cuidado cr&iacute;tico causando estr&eacute;s y contribuyendo a la sensaci&oacute;n de irritabilidad y fatiga.<sub>1,2</sub></p>       <p>Los efectos asociados a niveles de ruido excesivos en unidades de cuidado cr&iacute;tico var&iacute;an seg&uacute;n la edad del paciente, en adultos es frecuente la privaci&oacute;n del sue&ntilde;o que repercute de forma negativa en aspectos f&iacute;sicos, psicol&oacute;gicos y de conducta, retrasando con ello en muchos casos el proceso de recuperaci&oacute;n de la enfermedad; en ni&ntilde;os pueden presentarse traumas ac&uacute;sticos, respuestas de estr&eacute;s fisiol&oacute;gico, privaci&oacute;n del sue&ntilde;o, confusi&oacute;n y desorientaci&oacute;n; por &uacute;ltimo en neonatos puede influenciar la aparici&oacute;n de problemas cl&iacute;nicos como apnea, bradicardia, deficiencias nutricionales, cambios en la percepci&oacute;n del sonido, p&eacute;rdida de audici&oacute;n y alteraciones en el crecimiento y desarrollo normal del sistema nervioso central. mientras que en el personal de salud favorece la aparici&oacute;n del s&iacute;ndrome Burnout.<sub>1.3-12</sub></p>      <p>A nivel normativo se resaltan en la tem&aacute;tica de niveles de ruido est&aacute;ndares internacionales como los de la EPA (45 dBA en el d&iacute;a y 35 dBA en la noche), el Consejo Internacional de Ruido - INC (45 dBA d&iacute;a y 20 dBA noche), el Instituto Nacional para la Seguridad y Salud Ocupacional - NIOSH (40 dBA d&iacute;a y 35 dBA noche), la OMS (35 dBA d&iacute;a y 30dBA noche) y el Real Decreto Ley 1386 de 1989 - RDL-1386 (40 dBA d&iacute;a y 35 dBA noche) citados por varios autores.<sub>1,13-17</sub></p>      <p>A nivel nacional la Resoluci&oacute;n 8321 del 4 de Agosto de 1983 - R-8321 (aplicable para mediciones en interiores), dicta normas sobre la protecci&oacute;n y conservaci&oacute;n de la audici&oacute;n de la salud y el bienestar de las personas por causa de la producci&oacute;n y emisi&oacute;n de ruidos, especificando para zonas de tranquilidad niveles de presi&oacute;n sonora de 45 dBA para el per&iacute;odo diurno y nocturno.<sub>18</sub></p>      <p>Por otro lado, la Resoluci&oacute;n 627 del 7 de abril de 2006 - R-627 (aplicable para mediciones en ambientes exteriores) establece la norma nacional de emisi&oacute;n de ruido y ruido ambiental se&ntilde;alando como est&aacute;ndares m&aacute;ximos permisibles de niveles de emisi&oacute;n de ruido para el Sector A tranquilidad y silencio, valores de 55 para el d&iacute;a y de 50 para la noche.<sub>19</sub></p>      <p>Para las unidades de cuidado intensivo adulto se reportan niveles promedio de 65 dBA, Elliott et al., en su estudio registran valores comprendidos entre 48 dBA - 75 dBA,<sub>20</sub> de la misma manera en Maracay (Venezuela) se encontraron niveles entre 66 dBA - 70 dBA, en Michigan (Estados Unidos) registros entre 60 dBA - 72 dBA y en Sao Paulo (Brasil), resultados entre 58,9 dBA - 64,1 dBA para el LA<sub>eq'16,20-22</sub></p>      <p>Por lo anterior, el prop&oacute;sito del presente estudio es evaluar el nivel continuo equivalente de ruido en una unidad de cuidado intensivo adulto perteneciente a un hospital de la ciudad de Santa Marta con los niveles sugeridos por los est&aacute;ndares internacionales, puesto que a nivel local se adolece de un estudio que permita verificar los niveles actuales de ruido manejados por estas unidades de cuidado cr&iacute;tico.</p>    <br>      <p align="center"><font size="3"><b>Materiales y m&eacute;todos</b></font></p>      <p><b>&Aacute;rea de estudio</b>    ]]></body>
<body><![CDATA[<br> El estudio se desarroll&oacute; en la Unidad de Cuidado Intensivo Adulto (UCIA) de un hospital ubicado en la ciudad de Santa Marta (Colombia). La unidad cuenta con 19 camas habilitadas para el cuidado cr&iacute;tico. El hospital es un centro de atenci&oacute;n m&eacute;dica de alta complejidad en la regi&oacute;n, de car&aacute;cter p&uacute;blico que presta sus servicios m&eacute;dicos, al tiempo que se establece como escenario para la docencia universitaria en el &aacute;rea de la salud. En la UCIA laboran por turno 7 miembros del equipo asistencial, y la ocupaci&oacute;n promedio de camas en la unidad es de 52,6% (10 camas), siendo este el n&uacute;mero promedio de pacientes presentes en la UCIA.<sub>23</sub></p>      <p>A lo largo de un d&iacute;a en la UCIA se desarrollan tres turnos del personal asistencial (ma&ntilde;ana: 7:01-13:00, vespertina: 13:01-19:00 y noche: 19:01-7:00+1); as&iacute; mismo, a las 8:00, 12:00 y 16:00 se brinda la alimentaci&oacute;n al paciente. Finalmente, se establecen dos horarios de visita de familiares de 20 minutos, realizados a las 10:00 y las 17:00 h.</p>      <p><b>Dise&ntilde;o muestral</b>    <br> El muestreo se realiz&oacute; de forma continua durante 20 d&iacute;as en la UCIA entre los meses de agosto y septiembre de 2012, teniendo en cuenta la metodolog&iacute;a expuesta en el estudio desarrollado por V&eacute;lez-Pereira, y Fortes-Garrido et al., que emple&oacute; un son&oacute;metro tipo I marca Casella modelo CEL-633-C1K1&reg; y se program&oacute; para la toma de datos cada 60 segundos utilizando el filtro de ponderaci&oacute;n frecuencial A y el filtro de ponderaci&oacute;n temporal Fast. Dentro de los par&aacute;metros ac&uacute;sticos registrados se report&oacute; el LAm&iacute;n (para establecer el nivel de ruido m&iacute;nimo) y el LAmax (para establecer los valores m&aacute;ximos).<sub>24,25</sub></p>      <p>El son&oacute;metro se ubic&oacute; teniendo en cuenta la metodolog&iacute;a, la din&aacute;mica interna de la UCIA y recomendaciones de los coordinadores m&eacute;dicos. En la unidad se estableci&oacute; un punto de muestreo ubicado en el ambiente a una distancia de 55 cm del techo y 123 cm de la pared en un lugar central.</p>      <p><b>Procesamiento de la informac&oacute;n</b>    <br> Los datos obtenidos durante el muestreo realizado se procesaron inicialmente con la herramienta Microsoft Excel&reg; y posteriormente se ejecut&oacute; el an&aacute;lisis estad&iacute;stico con el programa Statgraphics Centurion XVII para determinar si existe una influencia de la hora del d&iacute;a y el nivel de ruido.</p>      <p><b>Nivel continuo equivalente</b>    <br> En las hojas de c&aacute;lculo trabajadas con Microsoft Excel&reg; se generaron los gr&aacute;ficos de l&iacute;nea y se representaron los resultados de las mediciones obtenidas en la UCIA (LAeq, LAFMax y LAFMin); adicionalmente se representaron los datos correspondientes bajo un periodo de integraci&oacute;n de 1 hora, lo que permiti&oacute; analizar durante el tiempo de muestreo la variabilidad asociada a ciclos horarios o diarios. Para la obtenci&oacute;n del promedio integrado se emple&oacute; la siguiente ecuaci&oacute;n:<sub>24</sub></p>      <p align="center"><img src="img/revistas/reus/v17n2/v17n2a02f01.gif"></p>    ]]></body>
<body><![CDATA[<br>      <p>Donde i corresponde a la observaci&oacute;n del nivel continuo equivalente en ponderado A reportada en el intervalo de horario j, y n es el n&uacute;mero total de observaciones i en la hora j.</p>      <p>Con el paquete Statgraphics Centurion XVII se determin&oacute; el comportamiento estad&iacute;stico de los niveles de ruido en la UCIA comparando las medias integradas horarias de LAeq de cada hora durante los 20 d&iacute;as de muestreo; para ello se elabor&oacute; un an&aacute;lisis de varianza - ANOVA que permiti&oacute; establecer la existencia o inexistencia de diferencias estad&iacute;sticamente significativas entre las medias horarias integradas del LAeq de los per&iacute;odos evaluados en la unidad.<sub>24,26</sub></p>    <br>      <p align="center"><font size="3"><b>Resultados</b></font></p>      <p>En el <a href="#g01">gr&aacute;fico 1</a> se muestra el nivel continuo equivalente de ruido bajo el per&iacute;odo de integraci&oacute;n de 10 minutos en la UCIA, los resultados presentaron un comportamiento estable en los valores del LA<sub>eq,10min</sub> registrados cada 24 horas, mostrando valores similares a las mismas horas (10:30 horas) y formando algunos grupos, del 19/08/2012 al 22/08/2012 con valores de 56 dBA aproximadamente cada 24 horas; de la misma manera del 23/08/2012 al 24/08/2012 con valores de 57 dBA, del 29/08/2012 al 02/09/2012 con valores de 55 dBA y del 03/09/2012 al 07/09/2012 con valores de 58 dBA, lo que sugiere valores promedio de 57 dBA aproximadamente a las 10:30 horas de cada d&iacute;a de muestreo en la UCIA.</p>      <p>Observando individualmente cada intervalo de 24 horas se detectaron descensos en los niveles de ruido en cada intervalo espec&iacute;ficamente entre las 22:00 - 03:00 horas de cada intervalo diario.</p>      <p align="center"><a name="g01"></a><img src="img/revistas/reus/v17n2/v17n2a02g01.jpg"></p>    <br>       <p align="center"><a name="t01"></a><img src="img/revistas/reus/v17n2/v17n2a02t01.gif"></p>    ]]></body>
<body><![CDATA[<br>      <p>Los valores del LA<sub>eq,10min</sub> presentan un rango de gran amplitud debido a que los registros se encontraron entre 49 dBA - 71 dBA, por su parte el comportamiento de los valores m&aacute;ximos presentados en esta UCIA fue semejante al presentado por el LA<sub>eq,10min</sub>reportando valores de 90,73 dBA correspondiente al d&iacute;a 25/08/2012 a las 15:30 horas y de 91,19 dBA correspondiente al d&iacute;a 30/08/2012 a las 18:30 horas; este &uacute;ltimo, probablemente asociado al horario de entrega de turnos dentro de la unidad. Con relaci&oacute;n a los m&iacute;nimos se observa que el comportamiento se adapta a la tendencia mostrada por el LA<sub>eq,10min</sub> con valores de 46,65 dBA a las 02:20 horas y de 47,37 dBA a las 02:40 horas de los d&iacute;as 22/08/2012 y 26/08/2012 respectivamente. Adicionalmente con la <a href="#g01">gr&aacute;fico 1</a> se evidencian muy pocas diferencias entre el comportamiento de los d&iacute;as laborables o de mayor actividad (de lunes a viernes) y los fines de semana (s&aacute;bados y domingos).</p>      <p>En cuanto a la variaci&oacute;n horaria, los datos de la <a href="#t01">tabla 1</a> permite establecer por el an&aacute;lisis de varianza que la hora del d&iacute;a tiene un incidencia significativa en el nivel de ruido continuo equivalente en ponderaci&oacute;n A, existiendo una diferencia estad&iacute;sticamente significativa entre las medias horarias, con un nivel del 95,0% de confianza; mientras que el an&aacute;lisis ANOVA evidencia que no hay una diferencia significativa entre los d&iacute;as laborables y los fines de semana.</p>    <br>      <p align="center"><font size="3"><b>Discusi&oacute;n</b></font></p>      <p>Los resultados reportados por la unidad de cuidado intensivo adulto para el LA<sub>eq</sub> muestran claramente registros superiores a los sugeridos por la OMS; de hecho comparando los registros con est&aacute;ndares internacionales referenciados anteriormente se evidencia que difieren de las normas aplicadas en varios pa&iacute;ses, especialmente del l&iacute;mite de 20 dBA durante la noche establecido por el INC y superado en la UCIA por casi el doble de lo establecido, puesto que en ninguna de las mediciones se obtuvo un valor cercano a 20 dBA, a diferencia del l&iacute;mite m&aacute;s alto fijado por est&aacute;ndares internacionales para per&iacute;odo nocturno y que corresponde a 35 dBA el cual es superado en menor medida.</p>      <p>Por otro lado, se encontr&oacute; que los l&iacute;mites fijados para el horario diurno son m&aacute;s altos que los fijados para el horario nocturno, de igual manera si se comparan con los registros se observa que es superado en el 100% de las mediciones, pues en ninguno de los casos se obtuvieron valores por debajo de los 45 dBA (<a href="#g02">Gr&aacute;fico 2</a>).<sub></sub></p>      <p>De igual manera, al contrastar los resultados obtenidos en la UCIA, con los l&iacute;mites aplicables a nivel nacional para ambientes interiores en zonas de tranquilidad como hospitales (45 dBA en el d&iacute;a y en la noche) se evidencia que el l&iacute;mite es superado en ambos per&iacute;odos diurno y nocturno, incluso en los horarios correspondientes a la madrugada (registros m&aacute;s bajos), los valores reportados se alejan considerablemente de los niveles m&aacute;ximos permitidos por la normativa aplicable (<a href="#g02">Gr&aacute;fico 2</a>).</p>      <p>Aunque los LAeq, LAFmax y LAFmin registrados por el estudio son valores cercanos a los publicados por otros autores para ruido en las unidades de cuidado intensivo en al &aacute;mbito nacional e internacional, es preciso resaltar que estos niveles pueden llegar a tener implicaciones dentro de la unidad, en funci&oacute;n a la respuesta a est&iacute;mulos auditivos que depende de cada individuo, a la sensibilidad de cada paciente al ruido y a la presencia de patolog&iacute;as previas.<sub>16,21,22,27-29</sub></p>      <p>Los efectos sobre los pacientes son producidos por la exposici&oacute;n persistente a altos niveles de ruido, pueden repercutir en la estancia del paciente pues el proceso de recuperaci&oacute;n es m&aacute;s lento, aumentando con ello el tiempo de permanencia en la unidad, e incrementando los costos de la estancia.<sub>30</sub></p>      ]]></body>
<body><![CDATA[<p align="center"><a name="g02"></a><img src="img/revistas/reus/v17n2/v17n2a02g02.jpg"></p>    <br>      <p>Estudios desarrollados en Colombia por Achury-Salada&ntilde;a y Achury, describen la influencia de variables como el ruido en el descanso del paciente, fuentes de ruido como los equipos biom&eacute;dicos, el tel&eacute;fono y las conversaciones del personal m&eacute;dico, alteran el ciclo del sue&ntilde;o-vigilia, disminuyendo con ello la calidad del sue&ntilde;o.<sub>31</sub></p>      <p>Adicionalmente Fajardo et al., mencionan en su publicaci&oacute;n la influencia del ruido en la recuperaci&oacute;n del paciente internado;<sub>27</sub> teniendo en cuenta que los resultados de las mediciones arrojaron valores por encima de los l&iacute;mites evaluados en su estudio (45 dBA d&iacute;a y 35 dBA noche), exponen la necesidad de implementar acciones que contribuyan a alcanzar niveles &oacute;ptimos en las unidades de cuidado cr&iacute;tico.<sub>27,31</sub></p>      <p>Por otro lado, la exposici&oacute;n constante por parte del personal m&eacute;dico, enfermeras y auxiliares de enfermer&iacute;a a estos niveles de ruido registrados en la UCIA objeto de estudio durante el tiempo laboral, incrementa el riesgo de causar desgaste en el personal, disminuci&oacute;n del rendimiento e incremento de costos por incapacidades, estr&eacute;s del personal o en el caso m&aacute;s grave por el desarrollo de enfermedad profesional asociada a la exposici&oacute;n persistente de niveles de ruido.<sub>30</sub></p>      <p>En este contexto la literatura expone que en ocasiones en las unidades de cuidado intensivo se omite durante el dise&ntilde;o y remodelaci&oacute;n la utilizaci&oacute;n de materiales que favorezcan la absorci&oacute;n de las ondas sonoras, en lugar de ello se encuentran superficies con poca o nula absorci&oacute;n ac&uacute;stica que contribuye a la generaci&oacute;n de ruido y por ende, tienen implicaciones sobre el bienestar del personal, de los pacientes internados en las unidades de cuidado cr&iacute;tico y posiblemente sobre los costos dentro de la unidad.<sub>28</sub></p>      <p>Teniendo en cuenta los niveles de ruido obtenidos en el presente estudio y las posibles implicaciones que puede tener a nivel econ&oacute;mico, desde el punto de vista de salud del paciente y del personal asistencial que labora dentro de las unidades de cuidado cr&iacute;tico, es importante realizar seguimientos al nivel de ruido que permitan identificar y entender la din&aacute;mica ac&uacute;stica dentro del funcionamiento normal de las unidades de cuidado intensivo, y con ello adoptar programas y/o estrategias que contribuyan al bienestar fisiol&oacute;gico y psicol&oacute;gico de los pacientes y del personal que labora dentro de estas unidades.<sub></sub></p>      <p>En consecuencia ser&iacute;a interesante realizar un estudio indicando el porcentaje de eficiencia en la reducci&oacute;n de los niveles de ruido utilizando materiales absorbentes en el dise&ntilde;o de las unidades de cuidado cr&iacute;tico, y comprobar si es totalmente eficiente esta medida, o si por el contrario se requerir&iacute;a la adopci&oacute;n de medidas adicionales para mantener los niveles dentro de los l&iacute;mites establecidos por organizaciones internacionales.</p>      <p><b>Agradecimientos</b>    <br> Los autores expresan sus agradecimientos al personal asistencial y administrativo de la unidad de cuidado intensivo adulto por su colaboraci&oacute;n. De igual manera, se agradece a la Universidad del Magdalena y al Departamento Administrativo de Ciencia, Tecnolog&iacute;a e Innovaci&oacute;n - Colciencias por el apoyo a trav&eacute;s del Programa J&oacute;venes Investigadores e Innovadores.<sub></sub></p>    ]]></body>
<body><![CDATA[<br>      <p align="center"><font size="3"><b>Referencias</b></font></p>      <!-- ref --><p>1. Basco-Prado L, Fari&ntilde;as-Rodr&iacute;guez S, Hidalgo-Blanco M&Aacute;. Caracter&iacute;sticas del sue&ntilde;o de los pacientes en una unidad de cuidados intensivos. Rev Cuba Enferm. junio de 2010;26(2):0-0.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000075&pid=S0124-7107201500020000200001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>2. Epp K. Burnout in critical care nurses: a literature review. Dynamics. 2012;23(4):25-31.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000077&pid=S0124-7107201500020000200002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>3. Christensen M. What knowledge do ICU nurses have with regard to the effects of noise exposure in the Intensive Care Unit? Intensive Crit Care Nurs. agosto de 2005;21(4):199-207.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000079&pid=S0124-7107201500020000200003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>4. Christensen M. Noise levels in a general intensive care unit: a descriptive study. Nurs Crit Care. 1 de julio de 2007;12(4):188-97.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000081&pid=S0124-7107201500020000200004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><sub></sub></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>5. Carvalho WB, Pedreira MLG, de Aguiar MAL. Noise level in a pediatric intensive care unit. J Pediatr (Rio J). diciembre de 2005;81(6):495-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S0124-7107201500020000200005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>6. Fern&aacute;ndez DP, Cruz JN. Efectos del ruido en ambiente hospitalario neonatal. Cienc Trab. junio de 2006;8(20):65-73.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0124-7107201500020000200006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>7. Alvarez AA, Terr&oacute;n A, Boschi C, G&oacute;mez M. Review of noise in neonatal intensive care units - regional analysis. J Phys Conf Ser. 1 de noviembre de 2007;90(1):012038.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0124-7107201500020000200007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>8. Drouot X, Cabello B, d’Ortho M-P, Brochard L. Sleep in the intensive care unit. Sleep Med Rev. octubre de 2008;12(5):391-403.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0124-7107201500020000200008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>9. Chang TY, Lai YA, Hsieh HH, Lai JS, Liu CS. Effects of environmental noise exposure on ambulatory blood pressure in young adults. Environ Res. octubre de 2009;109(7):900-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0124-7107201500020000200009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>10. Altuncu E, Akman I, Kulekci S, Akdas F, Bilgen H, Ozek E. Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette. Int J Pediatr Otorhinolaryngol. 2009;73(7):951-3.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0124-7107201500020000200010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>11. Kamdar BB, King LM, Collop NA, Sakamuri S, Colantuoni E, Neufeld KJ, et al. The effect of a quality improvement intervention on perceived sleep quality and cognition in a medical ICU. Crit Care Med. marzo de 2013;41(3):800-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0124-7107201500020000200011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>12. Garrido-Galindo AP, Camargo-Caicedo Y, V&eacute;lez-Pereira AM. Nivel continuo equivalente de ruido en la unidad de cuidado intensivo neonatal asociado al s&iacute;ndrome de burnout. Enferm Intensiva. 2015;26(3):92-100.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0124-7107201500020000200012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>13. EPA USO of NA and. Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety. for sale by the Supt. of Docs., U.S. Govt. Print. Off.; 1974. 196 p.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0124-7107201500020000200013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>14. American College of Critical Care Medicine, Society of Critical Care Medicine. Guidelines for intensive care unit design. Crit Care Med. 1995;23(3):582-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0124-7107201500020000200014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>15. Berglund B, Lindvall T, Schwela DH, others. Gu&iacute;as para el ruido urbano. Cent Panam Ing Sanit Cienc Ambiente OPSCEPIS (Internet). 1999 (citado 18 de mayo de 2015); Disponible en: <a href="https://editorial.cda.ulpgc.es/ftp/Instalaciones2/ACUSTICA/ANEXO/1-Comodidad/OMSalud-Guias%20para%20el%20Ruido%20Urbano.pdf" target="_blank">https://editorial.cda.ulpgc.es/ftp/Instalaciones2/ACUSTICA/ANEXO/1-Comodidad/OMSalud-Guias%20para%20el%20Ruido%20Urbano.pdf</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0124-7107201500020000200015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Konkani A, Oakley B. Noise in hospital intensive care units-a critical review of a critical topic. J Crit Care. octubre de 2012;27(5):522.e1-522.e9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0124-7107201500020000200016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>17. Guidelines/Practice Parameters Committee of the, American College of Critical Care Medicine, Society of Critical Care Medicine. Guidelines for intensive care unit design. Crit Care Med. 1995;23(3):582-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0124-7107201500020000200017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>18. Ministerio de Salud de Colombia. Resolucion 8321 de 1983, Agosto 4, por la cual se dictan normas sobre proteccion y conservacion de la audicion de la salud y el bienestar de las personas por causa de la produccion y emision de ruidos. Resoluci&oacute;n 1983.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0124-7107201500020000200018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>19. Rep&uacute;blica de Colombia. Ministerio de Ambiente, Vivienda y Desarrollo Territorial. Resoluci&oacute;n 627 de 2006 por la cual se establece la norma nacional de emisi&oacute;n de ruido y ruido ambiental. Resoluci&oacute;n 627 de 2006: 29.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0124-7107201500020000200019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>20. Elliott R, McKinley SM, Eager DM. A pilot study of sound levels in an australian adult general intensive care unit. Noise Health. enero de 2010;12:26-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0124-7107201500020000200020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>21. Colina LM, Freites A, Guti&eacute;rrez P. Efectos no auditivos que ocasiona el ruido al personal de enfermer&iacute;a que labora en la unidad de cuidados intensivos de adultos (UCIA) del Hospital Central de Maracay. &#91;Internet&#93; &#91;Tesis para optar el titulo de Licenciado en Enfermer&iacute;a&#93;. &#91;Venezuela&#93;: Universidad Central de Venezuela; 2000. Disponible en: <a href="http://saber.ucv.ve/jspui/handle/123456789/408" target="_blank">http://saber.ucv.ve/jspui/handle/123456789/408</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0124-7107201500020000200021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Macedo ISC, Mateus DC, Costa EDMGC, Asprino ACL, Louren&ccedil;o EA. Noise assessment in intensive care units. Braz J Otorhinolaryngol. 2009;75(6):844-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0124-7107201500020000200022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>23. V&eacute;lez-Pereira AM, Camargo Caicedo Y. An&aacute;lisis de los factores ambientales y ocupacionales en la concentraci&oacute;n de aerobacterias en unidades de cuidado intensivo del Hospital Universitario Fernando Troconis, 2009 Santa Marta - Colombia. Rev Cuid. 2014;5(1):595-605.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0124-7107201500020000200023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>24. V&eacute;lez-Pereira AM. Evaluaci&oacute;n de niveles de ruido en la unidad de cuidados intensivos neonatal del Hospital Juan Ram&oacute;n Jim&eacute;nez (Tesis de Fin de Master, Master en Tecnolog&iacute;a Ambiental y Gesti&oacute;n del Agua). (Huelva, Espa&ntilde;a): Universidad Internacional de Andaluc&iacute;a - Universidad de Huelva; 2010.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0124-7107201500020000200024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>25. Fortes-Garrido JC, Velez-Pereira AM, G&aacute;zquez M, Hidalgo-Hidalgo M, Bol&iacute;var JP. The characterization of noise levels in a neonatal intensive care unit and the implications for noise management. J Environ Health Sci Eng. 22 de julio de 2014;12(1):104.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0124-7107201500020000200025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>26. Berg AL, Chavez CT, Serpanos YC. Monitoring noise levels in a tertiary neonatal intensive care unit. CICSD. 2010;37:69-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0124-7107201500020000200026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>27. Fajardo DL, Gallego SY, Argote L&Aacute;. Noise levels in the Hospital Universitario del Valle newborn intensive care unit &laquo;Cirena&raquo;, Cali, Colombia. Colomb M&eacute;dica. 2007;38(4 Supl 2):64-71.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0124-7107201500020000200027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>28. Johansson L, Bergbom I, Waye KP, Ryherd E, Lindahl B. The sound environment in an ICU patient room-A content analysis of sound levels and patient experiences. Intensive Crit Care Nurs. octubre de 2012;28(5):269-79.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0124-7107201500020000200028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>29. Ayll&oacute;n-Garrido N, &Aacute;lvarez-Gonz&aacute;lez M, Gonz&aacute;lez-Garc&iacute;a M. Factores ambientales estresantes percibidos por los pacientes de una unidad de cuidados intensivos. Enferm Intensiva. diciembre de 2007;18(4):159-67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0124-7107201500020000200029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>30. Mart&iacute;nez-Su&aacute;rez P, Moreno-Jim&eacute;nez A. El ambiente ac&uacute;stico de los hospitales de Madrid: metodolog&iacute;a de an&aacute;lisis y diagn&oacute;stico con SIG. Cuad Geogr&aacute;ficos Univ Granada. 2006;(39):125-46.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0124-7107201500020000200030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>31. Achury-Salda&ntilde;a DM, Achury LF. Sue&ntilde;o en el paciente cr&iacute;tico: una necesidad insatisfecha en la unidad de cuidado intensivo. Investig En Enferm Imagen Desarro. 19 de agosto de 2011;12(1):25-42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S0124-7107201500020000200031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>  </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Basco-Prado]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Fariñas-Rodríguez]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hidalgo-Blanco]]></surname>
<given-names><![CDATA[MÁ]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Características del sueño de los pacientes en una unidad de cuidados intensivos]]></article-title>
<source><![CDATA[Rev Cuba Enferm]]></source>
<year>juni</year>
<month>o </month>
<day>de</day>
<volume>26</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>0-0</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Epp]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Burnout in critical care nurses: a literature review]]></article-title>
<source><![CDATA[Dynamics]]></source>
<year>2012</year>
<volume>23</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>25-31</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Christensen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[What knowledge do ICU nurses have with regard to the effects of noise exposure in the Intensive Care Unit?]]></article-title>
<source><![CDATA[Intensive Crit Care Nurs]]></source>
<year>agos</year>
<month>to</month>
<day> d</day>
<volume>21</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>199-207</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Christensen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise levels in a general intensive care unit: a descriptive study]]></article-title>
<source><![CDATA[Nurs Crit Care]]></source>
<year>1 de</year>
<month> j</month>
<day>ul</day>
<volume>12</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>188-97</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Pedreira]]></surname>
<given-names><![CDATA[MLG]]></given-names>
</name>
<name>
<surname><![CDATA[de Aguiar]]></surname>
<given-names><![CDATA[MAL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise level in a pediatric intensive care unit]]></article-title>
<source><![CDATA[J Pediatr (Rio J)]]></source>
<year>dici</year>
<month>em</month>
<day>br</day>
<volume>81</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>495-8</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
<name>
<surname><![CDATA[Cruz]]></surname>
<given-names><![CDATA[JN]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Efectos del ruido en ambiente hospitalario neonatal]]></article-title>
<source><![CDATA[Cienc Trab]]></source>
<year>juni</year>
<month>o </month>
<day>de</day>
<volume>8</volume>
<numero>20</numero>
<issue>20</issue>
<page-range>65-73</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alvarez]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Terrón]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Boschi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Review of noise in neonatal intensive care units - regional analysis]]></article-title>
<source><![CDATA[J Phys Conf Ser]]></source>
<year>1 de</year>
<month> n</month>
<day>ov</day>
<volume>90</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>012038</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Drouot]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Cabello]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[d'Ortho]]></surname>
<given-names><![CDATA[M-P]]></given-names>
</name>
<name>
<surname><![CDATA[Brochard]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sleep in the intensive care unit]]></article-title>
<source><![CDATA[Sleep Med Rev]]></source>
<year>octu</year>
<month>br</month>
<day>e </day>
<volume>12</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>391-403</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[TY]]></given-names>
</name>
<name>
<surname><![CDATA[Lai]]></surname>
<given-names><![CDATA[YA]]></given-names>
</name>
<name>
<surname><![CDATA[Hsieh]]></surname>
<given-names><![CDATA[HH]]></given-names>
</name>
<name>
<surname><![CDATA[Lai]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of environmental noise exposure on ambulatory blood pressure in young adults]]></article-title>
<source><![CDATA[Environ Res]]></source>
<year>octu</year>
<month>br</month>
<day>e </day>
<volume>109</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>900-5</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Altuncu]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Akman]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Kulekci]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Akdas]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Bilgen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ozek]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette]]></article-title>
<source><![CDATA[Int J Pediatr Otorhinolaryngol]]></source>
<year>2009</year>
<volume>73</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>951-3</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kamdar]]></surname>
<given-names><![CDATA[BB]]></given-names>
</name>
<name>
<surname><![CDATA[King]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Collop]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Sakamuri]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Colantuoni]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Neufeld]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of a quality improvement intervention on perceived sleep quality and cognition in a medical ICU]]></article-title>
<source><![CDATA[Crit Care Med]]></source>
<year>marz</year>
<month>o </month>
<day>de</day>
<volume>41</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>800-9</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garrido-Galindo]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Camargo-Caicedo]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Vélez-Pereira]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Nivel continuo equivalente de ruido en la unidad de cuidado intensivo neonatal asociado al síndrome de burnout]]></article-title>
<source><![CDATA[Enferm Intensiva]]></source>
<year>2015</year>
<volume>26</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>92-100</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="book">
<collab>EPA USO of NA and</collab>
<source><![CDATA[Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety]]></source>
<year>1974</year>
<page-range>196</page-range><publisher-name><![CDATA[Govt. Print. Off]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<collab>American College of Critical Care Medicine^dSociety of Critical Care Medicine</collab>
<article-title xml:lang="en"><![CDATA[Guidelines for intensive care unit design]]></article-title>
<source><![CDATA[Crit Care Med]]></source>
<year>1995</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>582-8</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berglund]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Lindvall]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Schwela]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
</person-group>
<source><![CDATA[Guías para el ruido urbano]]></source>
<year></year>
<publisher-name><![CDATA[Cent Panam Ing Sanit Cienc Ambiente OPSCEPIS]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Konkani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Oakley]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise in hospital intensive care units-a critical review of a critical topic]]></article-title>
<source><![CDATA[J Crit Care]]></source>
<year>octu</year>
<month>br</month>
<day>e </day>
<volume>27</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>522.e1-522.e9</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<collab>Guidelines/Practice Parameters Committee of the, American College of Critical Care Medicine^dSociety of Critical Care Medicine</collab>
<article-title xml:lang="en"><![CDATA[Guidelines for intensive care unit design]]></article-title>
<source><![CDATA[Crit Care Med]]></source>
<year>1995</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>582-8</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="">
<collab>Ministerio de Salud de Colombia</collab>
<source><![CDATA[Resolucion 8321 de 1983, Agosto 4, por la cual se dictan normas sobre proteccion y conservacion de la audicion de la salud y el bienestar de las personas por causa de la produccion y emision de ruidos]]></source>
<year>1983</year>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="">
<collab>República de Colombia^dMinisterio de Ambiente, Vivienda y Desarrollo Territorial</collab>
<source><![CDATA[Resolución 627 de 2006 por la cual se establece la norma nacional de emisión de ruido y ruido ambiental]]></source>
<year>2006</year>
<page-range>29</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elliott]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[McKinley]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Eager]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A pilot study of sound levels in an australian adult general intensive care unit]]></article-title>
<source><![CDATA[Noise Health]]></source>
<year>ener</year>
<month>o </month>
<day>de</day>
<volume>12</volume>
<page-range>26-36</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Colina]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Freites]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Efectos no auditivos que ocasiona el ruido al personal de enfermería que labora en la unidad de cuidados intensivos de adultos (UCIA) del Hospital Central de Maracay]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Macedo]]></surname>
<given-names><![CDATA[ISC]]></given-names>
</name>
<name>
<surname><![CDATA[Mateus]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[EDMGC]]></given-names>
</name>
<name>
<surname><![CDATA[Asprino]]></surname>
<given-names><![CDATA[ACL]]></given-names>
</name>
<name>
<surname><![CDATA[Lourenço]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise assessment in intensive care units]]></article-title>
<source><![CDATA[Braz J Otorhinolaryngol]]></source>
<year>2009</year>
<volume>75</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>844-6</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vélez-Pereira]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Camargo Caicedo]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Análisis de los factores ambientales y ocupacionales en la concentración de aerobacterias en unidades de cuidado intensivo del Hospital Universitario Fernando Troconis, 2009 Santa Marta - Colombia]]></article-title>
<source><![CDATA[Rev Cuid]]></source>
<year>2014</year>
<volume>5</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>595-605</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vélez-Pereira]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<source><![CDATA[Evaluación de niveles de ruido en la unidad de cuidados intensivos neonatal del Hospital Juan Ramón Jiménez]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fortes-Garrido]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Velez-Pereira]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Gázquez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hidalgo-Hidalgo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bolívar]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The characterization of noise levels in a neonatal intensive care unit and the implications for noise management]]></article-title>
<source><![CDATA[J Environ Health Sci Eng]]></source>
<year>22 d</year>
<month>e </month>
<day>ju</day>
<volume>12</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>104</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berg]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Chavez]]></surname>
<given-names><![CDATA[CT]]></given-names>
</name>
<name>
<surname><![CDATA[Serpanos]]></surname>
<given-names><![CDATA[YC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monitoring noise levels in a tertiary neonatal intensive care unit]]></article-title>
<source><![CDATA[CICSD]]></source>
<year>2010</year>
<volume>37</volume>
<page-range>69-72</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fajardo]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Gallego]]></surname>
<given-names><![CDATA[SY]]></given-names>
</name>
<name>
<surname><![CDATA[Argote]]></surname>
<given-names><![CDATA[LÁ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Noise levels in the Hospital Universitario del Valle newborn intensive care unit «Cirena», Cali, Colombia]]></article-title>
<source><![CDATA[Colomb Médica]]></source>
<year>2007</year>
<volume>38</volume>
<numero>4^s2</numero>
<issue>4^s2</issue>
<supplement>2</supplement>
<page-range>64-71</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johansson]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bergbom]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Waye]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
<name>
<surname><![CDATA[Ryherd]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Lindahl]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The sound environment in an ICU patient room-A content analysis of sound levels and patient experiences]]></article-title>
<source><![CDATA[Intensive Crit Care Nurs]]></source>
<year>octu</year>
<month>br</month>
<day>e </day>
<volume>28</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>269-79</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ayllón-Garrido]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Álvarez-González]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[González-García]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Factores ambientales estresantes percibidos por los pacientes de una unidad de cuidados intensivos]]></article-title>
<source><![CDATA[Enferm Intensiva]]></source>
<year>dici</year>
<month>em</month>
<day>br</day>
<volume>18</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>159-67</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez-Suárez]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno-Jiménez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[El ambiente acústico de los hospitales de Madrid: metodología de análisis y diagnóstico con SIG]]></article-title>
<source><![CDATA[Cuad Geográficos Univ Granada]]></source>
<year>2006</year>
<numero>39</numero>
<issue>39</issue>
<page-range>125-46</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Achury-Saldaña]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Achury]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sueño en el paciente crítico: una necesidad insatisfecha en la unidad de cuidado intensivo]]></article-title>
<source><![CDATA[Investig En Enferm Imagen Desarro]]></source>
<year>19 d</year>
<month>e </month>
<day>ag</day>
<volume>12</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>25-42</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
