<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0124-8146</journal-id>
<journal-title><![CDATA[Investigaciones Andina]]></journal-title>
<abbrev-journal-title><![CDATA[Investig. andina]]></abbrev-journal-title>
<issn>0124-8146</issn>
<publisher>
<publisher-name><![CDATA[Fundación Universitaria del Área Andina - FUNANDI]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0124-81462011000100003</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[REPRODUCIBILIDAD Y CONCORDANCIA PARA LA CARTA SNELLEN Y LEA EN LA VALORACIÓN DE LA AGUDEZA VISUAL EN INFANTES DE PRIMARIA]]></article-title>
<article-title xml:lang="en"><![CDATA[TEST-RETEST RELIABILITY AND AGREEMENT FOR SNELLEN AND LEA VISUAL CHART TO ASSESSMENT VISUAL ACUITY IN ELEMENTARY SCHOOL CHILDREN]]></article-title>
<article-title xml:lang="pt"><![CDATA[REPRODUTIBILIDADE E CONCORDÂNCIA PARA A CARTA SNELLEN E LEA NA VALORAÇÁO DA AGUDEZ VISUAL NAS CRIANÇAS DO FUNDAMENTAL I]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[León Álvarez]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Estrada Álvarez]]></surname>
<given-names><![CDATA[Jorge Mario]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Fundación Universitaria del Área Andina facultad de Ciencias de la Salud programa de Optometría]]></institution>
<addr-line><![CDATA[Pereira ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Fundación Universitaria del Área Andina facultad de Ciencias de la Salud ]]></institution>
<addr-line><![CDATA[Pereira ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2011</year>
</pub-date>
<volume>13</volume>
<numero>22</numero>
<fpage>122</fpage>
<lpage>135</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0124-81462011000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0124-81462011000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0124-81462011000100003&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción: la evaluación de la visión de un infante se determina empleando las cartas de agudeza visual, aunque se les conoce comúnmente con el nombre de "optotipos", de las cuales la más frecuentemente empleada es la Snellen. Objetivo: determinar la reproducibilidad inter observadores y la concordancia de dos test que miden la agudeza visual en infantes escolares. Materiales y métodos: se evaluaron 61 niños (122 ojos) visualmente sanos con edades entre los 6 a10 años de un colegio de la ciudad de Pereira. La agudeza visual (AV) fue valorada con una carta Snellen de letras y con una carta LEA por parte de dos evaluadores independientemente. Resultados: la AVpromedio fue de 0.0 unidades del logaritmo del mínimo ángulo de resolución (logMAR) (20/20) y la diferencia media entre los test fue -0.05 (IC95% -0.064 a -0.037) logMAR; el coeficiente de reproducibilidad (COR) fue mejor para la carta LEA que Snellen (±0.08 y 0.12) superior a lo reportado en estudios previos (±0.15). Conclusión: la concordancia con el coeficiente de correlación intraclase mostró ser moderada (0.493) y los límites de acuerdo mostraron que había una mayor variación entre las mediciones para cuando la AV era más alta. Las cartas LEA y Snellen mostraron una buena reproducibilidad, no obstante la variabilidad en las mediciones entre ellas indica que no son pruebas intercambiables.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction: the evaluation of the vision of an infant is determined using the visual acuity charts, although they are commonly referred to as the "optotypes", of which the most frequently used is the Snellen. Objetive: to determinate test retest reliability and the agreement of two tests used to assess elementary school children visual acuity. Methods: we evaluated 61 visual healthy children (122 eyes) ages 7 through 10 enrolled in elementary school of Pereira. Visual acuity (VA) was measured with Snellen letters chart and LEA symbols chart by two evaluators. Results: the average of VA was 0.0 of logarithm of minimum angle of resolution (logMAR), the mean difference between the test was -0.05 (CI95% -0.064 to -0.037) logMAR; the coefficient of repeatability (COR) was better for LEA symbols and Snellen chart (±0.08 and 0.12) than those reported in previous papers (±0.15). Conclusion: the coefficient correlation Intraclass (CCI) has indicated a moderate concordance (0.493) and the 95% limits of agreement showed a wider difference between the both charts measurements as while visual acuity was better. LEA symbols and Snellen chart have showed good test retest reliability, although the variability between both measurements indicates that they are not interchangeable test.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Introdução: a avaliação da visão de uma criança é determinada com o emprego das cartas de agudez visual. São conhecidas comumente como "optótipos", das quais a empregada com mais freqüência é a Snellen. Objetivo: determinar a reprodutibilidade entre observadores e a concordância de dois testes que medem a agudez visual em pequenos escolares. Materiais e métodos: avaliaram-se 61 crianças (122 olhos), visualmente sãs, de 6 a 10 anos de idade de um colégio da cidade de Pereira. A agudez visual (AV) foi valorizada com uma carta Snellen de letras e com uma carta LEA por parte de dois avaliadores independentemente. Resultados: a AV média foi de 0.0 unidades do logaritmo do ângulo mínimo de resolução (logMAR) (20/20) e a diferença média entre os três foi -0.0,5 (IC95% -0.064 a -0.037) logMAR; o coeficiente de reprodutibilidade (COR) foi maior para a carta LEA que Snellen (±0.08 e 0.12) superior ao reportado em estudos prévios (±0.15). Conclusão: a concordância com o coeficiente de correlação inter-classe mostrou ser moderada (0.493) e os limites de acordo mostraram que havia uma maior variação entre as medições quando a AV era mais alta. As cartas LEA e Snellen mostraram uma boa reprodutibilidade, embora a variabilidade nas medições indique que não são provas intercambiáveis.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Reproducibilidad de Resultados]]></kwd>
<kwd lng="es"><![CDATA[Agudeza Visual]]></kwd>
<kwd lng="es"><![CDATA[Carta LEA]]></kwd>
<kwd lng="es"><![CDATA[Carta Snellen]]></kwd>
<kwd lng="es"><![CDATA[Visión de los Niños]]></kwd>
<kwd lng="en"><![CDATA[Reproducibility of Results]]></kwd>
<kwd lng="en"><![CDATA[Visual Acuity]]></kwd>
<kwd lng="en"><![CDATA[LEA Symbol]]></kwd>
<kwd lng="en"><![CDATA[Snellen Chart]]></kwd>
<kwd lng="en"><![CDATA[Children Vision]]></kwd>
<kwd lng="pt"><![CDATA[Reprodutibilidade de Resultados]]></kwd>
<kwd lng="pt"><![CDATA[Agudez Visual]]></kwd>
<kwd lng="pt"><![CDATA[Carta LEA]]></kwd>
<kwd lng="pt"><![CDATA[Carta Snellen]]></kwd>
<kwd lng="pt"><![CDATA[Visão das Crianças]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">     <p align="center"><font size="4"><b>REPRODUCIBILIDAD Y CONCORDANCIA PARA LA CARTA SNELLEN Y LEA EN LA VALORACI&Oacute;N DE LA AGUDEZA VISUAL EN INFANTES DE PRIMARIA</b></font></p>     <p align="center"><b><font size="3">TEST-RETEST RELIABILITY AND AGREEMENT FOR SNELLEN AND LEA VISUAL CHART TO ASSESSMENT VISUAL ACUITY IN ELEMENTARY SCHOOL CHILDREN</font></b></p>     <p align="center"><font size="3"><b>REPRODUTIBILIDADE E CONCORD&Acirc;NCIA PARA A CARTA SNELLEN E LEA NA VALORA&Ccedil;&Aacute;O DA AGUDEZ VISUAL NAS CRIAN&Ccedil;AS DO FUNDAMENTAL I</b></font></p>     <p>Alejandro Le&oacute;n &Aacute;lvarez*    <br> Jorge Mario Estrada &Aacute;lvarez*</p>     <p>* Opt&oacute;metra y magister en Ciencias de la Visi&oacute;n, universidad de la Salle. Docente e investigador grupo Salud Visual. Facultad de Ciencias de la Salud programa de Optometr&iacute;a. Fundaci&oacute;n Universitaria del &Aacute;rea Andina seccional Pereira. <a href="mailto:aleon@funandi.edu.co"><u>aleon@funandi.edu.co</u></a></p>     <p>** Licenciado en matem&aacute;ticas y f&iacute;sica, universidad Tecnol&oacute;gica de pereira, Especialista en Epidemiolog&iacute;a, Fundaci&oacute;n Universitaria del &Aacute;rea Andina. Docente e investigador grupo Salud Visual. Facultad de Ciencias de la Salud. Fundaci&oacute;n Universitaria del &Aacute;rea Andina seccional Pereira. <a href="mailto:jestrada@funandi.edu.co"><u>jestrada@funandi.edu.co</u></a></p> <hr>     <p><b><font size="3">Resumen</font></b></p>     <p><b><i>Introducci&oacute;n: </i></b><i>la evaluaci&oacute;n de la visi&oacute;n de un infante se determina empleando las cartas de agudeza visual, aunque se les conoce com&uacute;nmente con el nombre de &quot;optotipos&quot;, de las cuales la m&aacute;s frecuentemente empleada es la Snellen.</i></p>     ]]></body>
<body><![CDATA[<p><b><i>Objetivo: </i></b><i>determinar la reproducibilidad inter observadores y la concordancia de dos test que miden la agudeza visual en infantes escolares.</i></p>     <p><b><i>Materiales y m&eacute;todos: </i></b><i>se evaluaron 61 ni&ntilde;os (122 ojos) visualmente sanos con edades entre los 6 a10 a&ntilde;os de un colegio de la ciudad de Pereira. La agudeza visual (AV) fue valorada con una carta Snellen de letras y con una carta LEA por parte de dos evaluadores independientemente.</i></p>     <p><b><i>Resultados: </i></b><i>la AVpromedio fue de 0.0 unidades del logaritmo del m&iacute;nimo &aacute;ngulo de resoluci&oacute;n (logMAR) (20/20) y la diferencia media entre los test fue -0.05 (IC95% -0.064 a -0.037) logMAR; el coeficiente de reproducibilidad (COR) fue mejor para la carta LEA que Snellen (&plusmn;0.08 y 0.12) superior a lo reportado en estudios previos (&plusmn;0.15).</i></p>     <p><b><i>Conclusi&oacute;n: </i></b><i>la concordancia con el coeficiente de correlaci&oacute;n intraclase mostr&oacute; ser moderada (0.493) y los l&iacute;mites de acuerdo mostraron que hab&iacute;a una mayor variaci&oacute;n entre las mediciones para cuando la AV era m&aacute;s alta. Las cartas LEA y Snellen mostraron una buena reproducibilidad, no obstante la variabilidad en las mediciones entre ellas indica que no son pruebas intercambiables.</i></p>     <p><b><i>Palabras clave: </i></b>Reproducibilidad de Resultados; Agudeza Visual; Carta LEA; Carta Snellen; Visi&oacute;n de los Ni&ntilde;os.</p> <hr>     <p><b><font size="3">Abstract</font></b></p>     <p><b><i>Introduction: </i></b><i>the evaluation of the vision of an infant is determined using the visual acuity charts, although they are commonly referred to as the &quot;optotypes&quot;, of which the most frequently used is the Snellen.</i></p>     <p><b><i>Objetive: </i></b><i>to determinate test retest reliability and the agreement of two tests used to assess elementary school children visual acuity.</i></p>     <p><b><i>Methods: </i></b><i>we evaluated 61 visual healthy children (122 eyes) ages 7 through 10 enrolled in elementary school of Pereira. Visual acuity (VA) was measured with Snellen letters chart and LEA symbols chart by two evaluators.</i></p>     <p><b><i>Results: </i></b><i>the average of VA was 0.0 of logarithm of minimum angle of resolution (logMAR), the mean difference between the test was -0.05 (CI95% -0.064 to -0.037) logMAR; the coefficient of repeatability (COR) was better for LEA symbols and Snellen chart (&plusmn;0.08 and 0.12) than those reported in previous papers (&plusmn;0.15).</i></p>     ]]></body>
<body><![CDATA[<p><b><i>Conclusion: </i></b><i>the coefficient correlation Intraclass (CCI) has indicated a moderate concordance (0.493) and the 95% limits of agreement showed a wider difference between the both charts measurements as while visual acuity was better. LEA symbols and Snellen chart have showed good test retest reliability, although the variability between both measurements indicates that they are not interchangeable test.</i></p>     <p><b><i>Keywords:</i></b><i> </i>Reproducibility of Results; Visual Acuity; LEA Symbol; Snellen Chart; Children Vision.</p> <hr>     <p><b><font size="3">Resumo</font></b></p>     <p><b><i>Introdu&ccedil;&atilde;o: </i></b><i>a avalia&ccedil;&atilde;o da vis&atilde;o de uma crian&ccedil;a &eacute; determinada com o emprego das cartas de agudez visual. S&atilde;o conhecidas comumente como &quot;opt&oacute;tipos&quot;, das quais a empregada com mais freq&uuml;&ecirc;ncia &eacute; a Snellen.</i></p>     <p><b><i>Objetivo: </i></b><i>determinar a reprodutibilidade entre observadores e a concord&acirc;ncia de dois testes que medem a agudez visual em pequenos escolares.</i></p>     <p><b><i>Materiais e m&eacute;todos: </i></b><i>avaliaram-se 61 crian&ccedil;as (122 olhos), visualmente s&atilde;s, de 6 a 10 anos de idade de um col&eacute;gio da cidade de Pereira. A agudez visual (AV) foi valorizada com uma carta Snellen de letras e com uma carta LEA por parte de dois avaliadores independentemente.</i></p>     <p><b><i>Resultados: </i></b><i>a AV m&eacute;dia foi de 0.0 unidades do logaritmo do &acirc;ngulo m&iacute;nimo de resolu&ccedil;&atilde;o (logMAR) (20/20) e a diferen&ccedil;a m&eacute;dia entre os tr&ecirc;s foi -0.0,5 (IC95% -0.064 a -0.037) logMAR; o coeficiente de reprodutibilidade (COR) foi maior para a carta LEA que Snellen (&plusmn;0.08 e 0.12) superior ao reportado em estudos pr&eacute;vios (&plusmn;0.15).</i></p>     <p><b><i>Conclus&atilde;o: </i></b><i>a concord&acirc;ncia com o coeficiente de correla&ccedil;&atilde;o inter-classe mostrou ser moderada (0.493) e os limites de acordo mostraram que havia uma maior varia&ccedil;&atilde;o entre as medi&ccedil;&otilde;es quando a AV era mais alta. As cartas LEA e Snellen mostraram uma boa reprodutibilidade, embora a variabilidade nas medi&ccedil;&otilde;es indique que n&atilde;o s&atilde;o provas intercambi&aacute;veis.</i></p>     <p><b><i>Palavras chave:</i></b><i> </i>Reprodutibilidade de Resultados; Agudez Visual; Carta LEA; Carta Snellen; Vis&atilde;o das Crian&ccedil;as.</p>     <p><i><b>Fecha de recibo:</b> </i>Noviembre/2010    ]]></body>
<body><![CDATA[<br>     <i><b>Fecha aprobaci&oacute;n:</b> </i>Marzo/2011</p> <hr>     <p><b><font size="3">Introducci&oacute;n</font></b></p>     <p>La evaluaci&oacute;n de la visi&oacute;n de un infante se determina empleando las cartas de agudeza visual, aunque se les conoce com&uacute;nmente con el nombre de <i>&quot;optotipos&quot;, </i>de las cuales la que se emplea con mayor frecuencia es la Snellen (<a href="#f1">figura 1a</a>). Esta fue dise&ntilde;ada por Hermann Snellen en 1892 y ha sido utilizada desde entonces modificando los optotipos (letras, s&iacute;mbolos o figuras) que contiene, pero conservando la misma distribuci&oacute;n, tama&ntilde;o y protocolo.</p>     <p align="center"><a name="f1"><img src="img/revistas/inan/v13n22/v13n22a03i1.jpg"></a></p>     <p>Pocos a&ntilde;os despu&eacute;s de que Snellen dise&ntilde;a y da a conocer esta prueba, Green<a href="#*" name="s*">*</a> propone una serie de modificaciones en la carta con el prop&oacute;sito de incrementar la eficiencia de la misma. Entre los cambios que propone est&aacute; el uso de optotipos con letras tipo no-serif (<a href="#f2">figura 2a</a>); una progresi&oacute;n 'geom&eacute;trica' en los cambios de nivel de agudeza visual, y un n&uacute;mero similar de figuras en cada l&iacute;nea de visi&oacute;n. No obstante, estas recomendaciones de Green no fueron tenidas en cuenta sino hasta casi un siglo despu&eacute;s por Ian Bailey y Jan Lovie (1), quienes dise&ntilde;an una nueva carta bas&aacute;ndose en los cambios sugeridos por Green. Esta nueva carta fue modificada por Ferris y colaboradores<sup>2 </sup>para llevar a cabo el estudio ETDRS (Early Treatment Diabetic Retinopathy Study) (<a href="#f1">figura 1b</a>) y desde entonces se ha convertido en el <i>'Gold Standard' </i>de las pruebas que eval&uacute;an la agudeza visual.</p>     <p align="center"><a name="f2"><img src="img/revistas/inan/v13n22/v13n22a03i2.jpg"></a></p>     <p>La carta Snellen presenta una serie de inconvenientes que le restan habilidad en el momento de determinar la visi&oacute;n de un sujeto (1, 3, 4): el n&uacute;mero de figuras en cada nivel es diferente, por lo que en unas ser&aacute;n m&aacute;s f&aacute;ciles de reconocer que en otras; las distancias entre optotipos tanto horizontal como vertical no son iguales, lo cual hace que la interacci&oacute;n de contorno (facilidad o dificultad para percibir separadas las letras) sea dis&iacute;mil y por tanto influye la facilidad o dificultad de determinar (<a href="#f1">figura 1a</a>).</p>     <p>Lovie-Kitchin (5) encontr&oacute; una alta correlaci&oacute;n (r: 0.94) entre las mediciones test-retest para la carta Snellen; sin embargo, el estudio de regresi&oacute;n y los l&iacute;mites de acuerdo que estim&oacute; (&plusmn;0.26 logMAR) indicaban que para observar un cambio en la agudeza visual evaluada con esta carta ser&iacute;an necesarias casi 3 l&iacute;neas de visi&oacute;n. Por ejemplo, si una persona obtuviera 20/20 para determinar si la AV mejor&oacute;, esta deber&aacute; ser de 20/10, o si se desea saber si empeor&oacute;, la medida debe ser inferior a 20/40. Por lo tanto la amplitud en los l&iacute;mites le restar&iacute;a validez al test. M&aacute;s recientemente Le&oacute;n y Estrada (6) empleando el coeficiente de correlaci&oacute;n concordancia (7) hallaron que la reproducibilidad intra observador y entre observadores era pobre (pc entre 0.73 a 0.80) y los l&iacute;mites de acuerdo eran amplios aunque inferiores a los reportados por Lovie-Kitchen (+/- 0.15 logMAR - 1&frac12; l&iacute;neas de visi&oacute;n).</p>     <p>Cuando los ni&ntilde;os est&aacute;n en edad escolar (primaria), la agudeza visual es usualmente determinada con cartas similares a las empleadas en personas adultas, aunque tambi&eacute;n es com&uacute;n que se emplee la &quot;E&quot; direccional o en algunos casos las figuras de Allen (<a href="#f2">figura 2b</a>). Estas &uacute;ltimas est&aacute;n basadas en dise&ntilde;os de representaciones que ya son poco caracter&iacute;sticas para los ni&ntilde;os, por lo cual podr&iacute;an tender a sub valorar la visi&oacute;n (8). M&aacute;s recientemente se emplea el test de LEA (<a href="#f3">figura 3 a</a>), que presenta un formato de carta tipo <i>'Bailey-Lovie' </i>y unos optotipos que representan 4 dibujos f&aacute;cilmente identificables por los ni&ntilde;os (c&iacute;rculo, casa, cuadrado, manzana) pero que a la vez tiene un radio de visibilidad similar a la &quot;C&quot; de Landolt (9) (<a href="#f3">figura 3b</a>), por lo cual los resultados obtenidos con esta prueba son comparables a las halladas en test para adultos. Cuando se alcanza el umbral de visi&oacute;n por parte del paciente, todas las figuras son similares al c&iacute;rculo y esto lo hace una manera fiable para saber si la persona est&aacute; simulando, y en el caso de los ni&ntilde;os no resulta desalentador porque no identifiquen o no respondan a la prueba.</p>     <p align="center"><a name="f3"><img src="img/revistas/inan/v13n22/v13n22a03i3.jpg"></a></p>     ]]></body>
<body><![CDATA[<p>A trav&eacute;s del tiempo diversas investigaciones evaluaron la reproducibilidad de la agudeza visual en ni&ntilde;os con la utilizaci&oacute;n de distintas pruebas (10, 11, 12) y con ellas se llega a concluir que el cambio se da en la visi&oacute;n cuando sobrepasa la l&iacute;nea y media de agudeza visual. Savage y colaboradores (13) hallaron que la carta LEA ten&iacute;a una moderada reproducibilidad entre observadores (r = 0.59) y la diferencia entre promedios para los dos evaluadores era 0.1 unidades logMAR (una l&iacute;nea de AV) con un intervalo de confianza 95% entre 0.0 a 0.2 unidades logMAR (de 0 a 2 l&iacute;neas de AV), lo cual indica que no existen discrepancias significativas entre los examinadores. Sin embargo, la mayor&iacute;a de estudios se han realizado sobre la concordancia entre la carta LEA y pruebas como el ETDRS (14, 15), la &quot;C&quot; de Landolt (16, 17) y el HOTV (18, 19) (<a href="#f2">figura 2c</a>) y se encuentra una concordancia entre 1 a 2 l&iacute;neas de agudeza visual, semejante a lo reportado para la reproducibilidad de los distintos test.</p>     <p>Al tener en cuenta que la carta tipo Snellen es la prueba empleada frecuentemente para la evaluaci&oacute;n de la visi&oacute;n de los ni&ntilde;os en Colombia; que el test LEA (formato Bailey-Lovie) es recomendado tanto para el tamizaje como para la evaluaci&oacute;n de los infantes y ni&ntilde;os en otros pa&iacute;ses (20), y que no se reportan datos acerca de la concordancia entre estas dos cartas, con este estudio se quiso determinar qu&eacute; tanta reproducibilidad ten&iacute;an (reproducibilidad inter observadora) y cu&aacute;n concordante eran entre ellas, en un grupo de infantes en edad escolar.</p>     <p><b><font size="3">Materiales y m&eacute;todos</font></b></p>     <p>Se realiz&oacute; un estudio de concordancia para determinar la reproducibilidad de los test Snellen (letras) y LEA, as&iacute; como el acuerdo entre ellos.</p>     <p>La poblaci&oacute;n estuvo constituida por ni&ntilde;os entre los 6 a 10 a&ntilde;os de edad pertenecientes a un colegio privado del &Aacute;rea Metropolitana de la ciudad de Pereira (Colombia). Fueron seleccionados de acuerdo a un muestreo no probabil&iacute;stico y seg&uacute;n el cumplimiento de criterios de inclusi&oacute;n determinados: agudeza visual de lejos y cerca mayor a 0.2 logMAR (logaritmo del m&iacute;nimo &aacute;ngulo de resoluci&oacute;n) (&gt;20/30); estereopsis &#8805; 50 segundos de arco evaluada con el test de Frisby, defecto refractivo corregido, segmento anterior y posterior libre de patolog&iacute;as oculares, y que reconocieran todas las letras del abecedario. Los criterios de exclusi&oacute;n fueron: ametrop&iacute;as superiores a +/- 1.00D esf&eacute;rica o cil&iacute;ndrica, presencia de ambliop&iacute;a y/o estrabismos.</p>     <p>Siguiendo los lineamientos de la declaraci&oacute;n de Helsinki y en cumplimiento del decreto 8430 de 1993 del Ministerio de Protecci&oacute;n Social, los padres o tutores de los menores de edad fueron informados en una reuni&oacute;n del colegio y mediante un volante escrito que se les envi&oacute; por intermedio de los profesores, sobre los pormenores de la investigaci&oacute;n; una vez al tanto del trabajo a realizar firmaron el consentimiento informado autorizando el procedimiento.</p>     <p>La muestra fue determinada con base en la f&oacute;rmula para medir reproducibilidad por el coeficiente de correlaci&oacute;n intraclase (CCI), empleando el software &quot;Tama&ntilde;o de la muestra versi&oacute;n 1.1&quot; (21) los par&aacute;metros ingresados fueron: error tipo I, 0.05; tipo II, 0.2; n&uacute;mero de evaluadores, 2; hip&oacute;tesis nula del coeficiente, 0.8; hip&oacute;tesis alterna para el coeficiente, 0.7; arrojando un tama&ntilde;o de 114 mediciones.</p>     <p>Las pruebas fueron realizadas por dos estudiantes de optometr&iacute;a de 3er a&ntilde;o, previamente entrenados por uno de los investigadores principales (ALA) con experiencia m&iacute;nima de 10 a&ntilde;os en el uso de estas. As&iacute; mismo los evaluadores realizaron un entrenamiento previo con cada uno de los ni&ntilde;os donde se les ense&ntilde;aron las figuras de la carta LEA y diferentes letras del abecedario, sin advertirles que solo unas cuantas de estas aparecer&iacute;an en la prueba. Siguiendo las recomendaciones dadas por Bailey (22), la agudeza visual con la carta Snellen se tom&oacute; de la siguiente forma: el sujeto fue ubicado a 6 metros de una carta Snellen de letras (Aroflex Bogot&aacute;, Col) la cual ten&iacute;a una luminancia de 120 nits y una iluminaci&oacute;n de 500 lux; con un parche pirata se le ocluy&oacute; uno de los ojos y se le pidi&oacute; que fijara el optotipo m&aacute;s grande de la prueba y a continuaci&oacute;n deb&iacute;a seguir nombr&aacute;ndolos en forma descendente hasta alcanzar el l&iacute;mite de resoluci&oacute;n visual. Este se determin&oacute; cuando el ni&ntilde;o no pod&iacute;a nombrar de forma correcta al menos el 60% de las letras que compon&iacute;a el nivel de agudeza visual que se evaluaba. En este momento el examen se detuvo y se anot&oacute; el resultado en la fracci&oacute;n de Snellen para luego ser convertida a unidades logMAR. Se dej&oacute; descansar al infante por espacio de dos minutos y se repiti&oacute; el procedimiento para el otro ojo.</p>     <p>Para convertir la agudeza visual de la fracci&oacute;n Snellen en unidades logMAR, se siguieron las recomendaciones dadas por Holladay (23) y Bailey (22) para obtener la siguiente f&oacute;rmula:</p>     <p>AV = MlogMAR+ (E x FCN) </p>     ]]></body>
<body><![CDATA[<p>En donde:</p>     <p>MlogMAR: m&aacute;ximo nivel logMAR calculado para la carta Snellen (ver <a href="#c1">Cuadro 1a</a>)</p>     <p align="center"><a name="c1"><img src="img/revistas/inan/v13n22/v13n22a03i4.jpg"></a></p>     <p>E: N&uacute;mero de optotipos (letras) no detectados o nombrados de forma err&oacute;nea.</p>     <p>FCN: Factor de conversi&oacute;n para cada optotipo en el m&aacute;ximo nivel logMAR calculado para la carta Snellen (<a href="#c1">Cuadro 1a</a>).</p>     <p>Ejemplo: el ni&ntilde;o obtuvo una AV de 20/20 m&aacute;s dos letras o puede decirse 20/15 menos 6 letras), por lo tanto</p>     <p>MlogMAR: -0.13 (20/15 - debido a que el sujeto observ&oacute; dos letras de este nivel). E: 6 (son 8 letras en el nivel del 20/15, pero solo observ&oacute; 2).</p>     <p>FCN: 0.0162 (<a href="#c1">cuadro1a</a>)</p>     <p>AVlogMAR: (-0.13) + (6 x 0.0162)= <b>-0.030 </b>logMAR <i>(20/20+2 o 20/15-6)</i></p>     <p>Para medir la agudeza visual con la carta LEA se emple&oacute; la &quot;LEA symbols 15-Line Distance Chart - cod 250150&quot; (Good-lite Elgin, IL) y se procedi&oacute; de la siguiente manera (15, 24): La prueba fue ubicada a 3 metros del sujeto a evaluar con una luminancia e iluminaci&oacute;n igual a la empleada para la carta Snellen; se ocluy&oacute; uno de los ojos del ni&ntilde;o y se le pidi&oacute; que observara las figuras m&aacute;s grandes del test. A continuaci&oacute;n deb&iacute;a nombrar los optotipos observados y seguir haci&eacute;ndolo para los siguientes niveles. La prueba se detuvo cuando el infante no fuese capaz de nombrar de forma correcta al menos 3 de los 5 optotipos del nivel que observaba. Los resultados fueron anotados en unidades logMAR. El otro ojo fue evaluado de forma similar dos minutos despu&eacute;s. Todo el procedimiento se repiti&oacute; por el segundo evaluador 30 minutos despu&eacute;s de las primeras pruebas. Para calcular el logMAR de este test se utiliz&oacute; la siguiente f&oacute;rmula:</p>     ]]></body>
<body><![CDATA[<p>AV=MlogMAR + (E x 0.02)</p>     <p>Donde &quot;MlogMAR&quot; es el logaritmo del m&iacute;nimo &aacute;ngulo de resoluci&oacute;n para el m&aacute;ximo nivel alcanzado; &quot;E&quot; es el n&uacute;mero de errores cometidos en el nivel.</p>     <p>Ejemplo: se obtiene 20/25-2 o se puede decir que es 20/30+3.</p>     <p align="center"><img src="img/revistas/inan/v13n22/v13n22a03i5.jpg"></p>     <p>MlogMAR: 0.1 (cuadro 1b - <i>20/25 m&aacute;ximo nivel de AV alcanzado)</i></p>     <p>E: 2 (contest&oacute; correctamente 3 figuras de las 5 de ese nivel de aV)</p>     <p>AVlogMAR: 0.1 + (2 x 0.02)= <b>0.14 </b>logMAR <i>(20/25-2 o 20/30+3)</i></p>     <p>Las variables de agudeza visual fueron representadas con medidas de tendencia central y dispersi&oacute;n seg&uacute;n previa prueba de normalidad; la reproducibilidad inter observadora fue determinada con el coeficiente de correlaci&oacute;n intraclase (25) con sus respectivos intervalos de confianza (95%), los coeficientes de reproducibilidad (COR) y la concordancia entre las pruebas fue determinada con los l&iacute;mites de acuerdo (95%) de Bland-Altman (26) (1999). Para realizar el an&aacute;lisis estad&iacute;stico se utilizaron los programas SPSS versi&oacute;n 17 (Statistical Package for the Social Sciences, Chicago, IL, USA) y Stata 10 (StataCorp LP Texas, USA)</p>     <p><b><font size="3">Resultados</font></b></p>     <p>Fueron evaluados 70 ni&ntilde;os (140 ojos) de los cuales quedaron incluidos 61 (122 ojos), los 9 sujetos excluidos fueron por presentar estrabismo (3), ametrop&iacute;a mayor a 2.00D (5), y por patolog&iacute;a de segmento posterior (1), con esto se obtuvieron 122 pares de mediciones. Los promedios de edad y agudeza visual para cada carta se observan en el <a href="#c2">Cuadro 2</a>.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="c2"><img src="img/revistas/inan/v13n22/v13n22a03i6.jpg"></a></p>     <p>La reproducibilidad entre observadores medida con el coeficiente de reproducibilidad (COR) mostr&oacute; ser mejor para la carta LEA en contraste con la carta Snellen (<a href="#c3">Cuadro 3</a>); el valor obtenido de COR para cada t&eacute;cnica es interpretada como la m&aacute;xima diferencia que se puede dar en la agudeza visual en mediciones repetidas, en este caso para la carta Snellen ser&iacute;a de 0.12 unidades logar&iacute;tmicas y para carta LEA 0.08 unidades logar&iacute;tmicas, as&iacute; mismo los coeficientes de correlaci&oacute;n intraclase (CCI) soportan esta afirmaci&oacute;n aunque para ambas pruebas indicar&iacute;an que la reproducibilidad ser&iacute;a casi perfecta (CCI &gt;0.80).</p>     <p>La gr&aacute;fica muestra la relaci&oacute;n negativa y estad&iacute;sticamente significativa entre el error de medida (diferencias en la medici&oacute;n por las dos cartas) y la magnitud de la agudeza visual, se evidencia que a medida que la estimaci&oacute;n en la agudeza visual en el paciente es menor, las diferencias entre las t&eacute;cnicas es mayor, es decir su error de medici&oacute;n aumenta.</p>     <p align="center"><a name="c3"><img src="img/revistas/inan/v13n22/v13n22a03i7.jpg"></a></p>     <p><b><font size="3">Discusi&oacute;n</font></b></p>     <p>Muchas pruebas empleadas en la pr&aacute;ctica cl&iacute;nica carecen de estudios de validaci&oacute;n y se da por sentado que estas realmente miden lo que deber&iacute;an medir. La aceptaci&oacute;n de estos test por parte de los profesionales est&aacute; m&aacute;s relacionada con la experiencia cl&iacute;nica que con el conocimiento sobre la fiabilidad de aquellas. A esto se le puede sumar que la existencia de numerosas pruebas que 'miden' lo mismo, dan lugar a un 'intercambio' emp&iacute;rico de los resultados cl&iacute;nicos, por lo cual en ocasiones se podr&iacute;a sub o sobre estimar el valor real del factor a evaluar; en este caso la agudeza visual.</p>     <p align="center"><img src="img/revistas/inan/v13n22/v13n22a03i8.jpg"></p>     <p>La diferencia de mediciones para la carta LEA entre el primer y segundo evaluador fue muy poca (0.01, &plusmn;0.04, IC 95% 0.003 a 0.017) e inferior a lo citado por Savage y colaboradores (13). La discrepancia entre ambos reportes puede estar dada por dos circunstancias: la primera, debido a que las edades de los ni&ntilde;os evaluados es diferente, pues Savage y colaboradores examinaron ni&ntilde;os entre los 3 a 6 a&ntilde;os, y esto tiene influencia en el momento de responder una prueba de visi&oacute;n: mientras los sujetos son m&aacute;s j&oacute;venes el &eacute;xito para realizar la evaluaci&oacute;n es inferior. Este hecho puede ser verificado cuando se observan los resultados publicados por Schmidt y colaboradores (27), el 4% de los infantes de 3 a&ntilde;os no fueron capaces de completar la prueba de LEA, mientras que a los 5 a&ntilde;os tan solo el 1.4% fue incapaz de culminarla.</p>     <p>El segundo factor tiene que ver la forma en que fueron anotados los resultados. Savage y colaboradores utilizaron un criterio de anotaci&oacute;n por l&iacute;neas de agudeza visual, es decir, si el sujeto era capaz de nombrar m&aacute;s del 60% de figuras en esa l&iacute;nea se anotaba como si la hubiera visto completa (de la l&iacute;nea del 20/20 ley&oacute; 5 de 7 letras por lo que la AV no ser&iacute;a 20/20-2 sino 20/20), mientras que para este estudio se emple&oacute; el criterio de anotaci&oacute;n por letras (figuras). Bailey y colaboradores (28) hallaron que entre m&aacute;s peque&ntilde;os eran los cambios en la escala de medici&oacute;n, la reproducibilidad de un test o la concordancia entre m&eacute;todos era mejor. Aparte de los factores anteriormente mencionados, cabe anotar que las pruebas estad&iacute;sticas empleadas por Savage para demostrar la reproducibilidad de un test (diferencia de medias y correlaci&oacute;n) no son las m&aacute;s pertinentes, puesto que no eval&uacute;an eficientemente las discrepancias sistem&aacute;ticas que se van presentando entre los evaluadores para cada par de mediciones (25,29).</p>     <p>Los coeficientes de reproducibilidad obtenidos con la carta LEA son superiores a los reportados para el test Sonksen (12) (0.17 logMAR - 1% l&iacute;neas de AV; edades entre 2 a 8 a&ntilde;os) y la carta ETDRS (30)</p>     ]]></body>
<body><![CDATA[<p>(0.15 logMAR - 1/ l&iacute;neas de AV; edades entre 6 a 10 a&ntilde;os). Entre las razones para una mayor reproducibilidad pueden estar que los optotipos empleados en la carta LEA son figuras f&aacute;cilmente reconocidas por los ni&ntilde;os, mientras que las letras son m&aacute;s complejas y pueden llevar a una mayor dificultad en la identificaci&oacute;n; adem&aacute;s las figuras de la carta LEA (aunque calibradas con la 'C' de Landolt), son un 25% m&aacute;s grandes que las letras del mismo nivel de agudeza visual, lo que podr&iacute;a favorecer a que sea m&aacute;s sencillo verlas (15). La reproducibilidad de la carta Snellen fue parecida aunque ligeramente mejor a la reportada por Le&oacute;n y Estrada (6) en sujetos adultos (&plusmn;0.15 logMAR - 1/ l&iacute;neas de AV), esto indica que en los ni&ntilde;os las mismas circunstancias reportadas para los adultos como una interacci&oacute;n de contorno variable para los diferentes niveles de visi&oacute;n y por las letras tipo 'Serif' que generan grados de visibilidad diferente para las letras, explicar&iacute;an la similitud de los resultados.</p>     <p>La concordancia entre la carta Snellen y LEA mostr&oacute; ser moderada y los l&iacute;mites de acuerdo indican una mayor variabilidad de las mediciones entre mayor era la agudeza visual. Estos resultados discrepan con los reportados por Dobson y colaboradores (14) y por Ruttum y Dahlgren (18) quienes hallaron que la variabilidad de las medidas se daba en cuanto mayor era la agudeza visual; sin embargo, estas diferencias pueden ser explicadas de la siguiente manera: en los niveles m&aacute;s altos de visi&oacute;n (&#8805;20/30), los optotipos de la carta Snellen guardan una distancia mayor a las figuras vecinas del mismo nivel as&iacute; como del superior e inferior con relaci&oacute;n a los niveles m&aacute;s bajos de visi&oacute;n (&#8804;20/40); esta discrepancia en las distancias produce una interacci&oacute;n de contorno diferente para cada letra, que hace m&aacute;s f&aacute;cilmente detectables unas que otras (31).</p>     <p>Los autores citados anteriormente emplearon cartas tipo Bailey Lovie o figuras que presentaban barras generadoras de una interacci&oacute;n de contorno similar para cada optotipo en cada nivel de visi&oacute;n, por lo que el grado de dificultad para todas las l&iacute;neas de agudeza visual ser&iacute;a similar. Ruttum y Dahlgren encontraron el mismo patr&oacute;n de variabilidad entre las pruebas hallado en el presente estudio, cuando emplearon las pruebas de LEA y HOTV en ojos ambliopes; explican que este fen&oacute;meno se presenta porque los campos receptores de los ambliopes <i>(&aacute;rea de la retina o de la corteza cerebral que al ser estimulada provoca una respuesta en la neurona que la inerva) </i>son m&aacute;s amplios con relaci&oacute;n a los ojos no-ambliopes, por lo cual al valorar la agudeza visual en los grados m&aacute;s altos de visi&oacute;n y la interacci&oacute;n de contorno, afectar&iacute;an principalmente la percepci&oacute;n de las figuras, acrecentando la dificultad de identificarlas.</p>     <p>Otro factor que tiene influencia en cuanto a la moderada concordancia y amplia variabilidad en los resultados, tiene que ver con el empleo de las letras y figuras diferentes para cada test. Las letras tipo serif tienen un grado de visibilidad distinto entre ellas, por lo que unas son m&aacute;s f&aacute;ciles de identificar que otras; este fen&oacute;meno fue reportado por Le&oacute;n y Estrada<sup>6</sup> al evaluar la reproducibilidad de la carta Snellen en sujetos adultos y cuando se observan los resultados presentados Dobson (14), Ruttum (18) y otros.</p>     <p>En conclusi&oacute;n, las dos cartas estudiadas presentan una alta reproducibilidad aunque es mayor para la carta LEA y similar a lo reportado en otros estudios para la Snellen, lo cual sugiere que son pruebas fiables en la evaluaci&oacute;n de la visi&oacute;n en ni&ntilde;os en edad escolar; y aunque se obtienen resultados similares, entre ellas no son intercambiables porque al presentar discrepancias en cuanto los optotipos empleados (tama&ntilde;o, forma, n&uacute;mero de ellos) generan una concordancia distinta seg&uacute;n la AV cambie (sea mejor o peor la visi&oacute;n).</p>     <p>Como la muestra evaluada fue obtenida por conveniencia, los resultados no deber&iacute;an ser generalizados a la poblaci&oacute;n base de donde fue extra&iacute;da; por lo tanto recomendamos ampliar el estudio con sujetos seleccionados aleatoriamente de una poblaci&oacute;n.</p>     <p><b>Agradecimientos</b></p>     <p>A la Fundaci&oacute;n Universitaria del &Aacute;rea Andina seccional Pereira y al Centro de Investigaciones de la misma instituci&oacute;n que patrocinaron el estudio; a los estudiantes Diana Quiroz, Diana Bedoya, Dayhana Ramos y Mauricio Bustamante por su colaboraci&oacute;n en la obtenci&oacute;n de los datos y el apoyo log&iacute;stico en el trabajo de campo.</p> <hr>     <p><a href="#s*" name="*">*</a> Green J. Notes on the clinical determination of the acuteness of vision, including the construction and gradation of optotypes, and on systems of notation. Trans Am Ophthalmol Soc1905;10(Pt 3):644-54.</p> <hr>     <p><b><font size="3">REFERENCIAS</font></b></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>1 Bailey IL, Lovie JE. <i>New design principles for visual acuity letter charts. </i>Am J Optom Physiol Opt1976 Nov;53(11):740-5.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0124-8146201100010000300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2 Ferris FL, 3rd, Kassoff A, Bresnick GH, Bailey I. <i>New visual acuity charts for clinical research. </i>Am J Ophthalmol1982 Jul;94(1):91-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0124-8146201100010000300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3 Pandit JC. <i>Testing acuity of vision in general practice: reaching recommended standard. </i>BMJ1994 Nov 26;309(6966):1408.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0124-8146201100010000300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4 Currie Z, Bhan A, Pepper I. <i>Reliability of Snellen charts for testing visual acuity for driving: prospective study and postal questionnaire. </i>BMJ2000 Oct 21;321(7267):990-2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0124-8146201100010000300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5 Lovie-Kitchin JE. <i>Validity and reliability ofvisual acuity measurements. </i>Ophthalmic Physiol Opt1988;8(4):363-70.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0124-8146201100010000300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6 Le&oacute;n A, Estrada J. <i>Prueba piloto para determinar la reproducibilidad de la carta Snellen al evaluar la agudeza visual en sujetos j&oacute;venes. </i>Ciencia y tecnolog&iacute;a para la salud visual y ocular 2009; 7(1):13-24.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0124-8146201100010000300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7 Lin LI. <i>A concordance correlation coefficient to evaluate reproducibility. </i>Biometrics1989 Mar;45(1):255-68.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0124-8146201100010000300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8 Mocan MC, Najera-Covarrubias M, Wright KW. Comparison of visual acuity levels in pediatric patients with amblyopia using Wright figures, Allen optotypes, and Snellen letters. J AAPOS2005 Feb;9(1):48-52.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0124-8146201100010000300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9 Hyvarinen L, Nasanen R, Laurinen P. <i>New visual acuity test forpre-school children. </i>Acta Ophthalmol (Copenh)1980 Aug;58(4):507-11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0124-8146201100010000300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10 McGraw PV, Winn B, Gray LS, Elliott DB. <i>Improving the reliability of visual acuity measures in young children. </i>Ophthalmic Physiol Opt2000 May;20(3):173-84.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0124-8146201100010000300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11 Holmes JM, Beck RW, Repka MX, Leske DA, Kraker RT, Blair RC, et al. <i>The amblyopia treatment study visual acuity testing protocol. </i>Arch Ophthalmol2001 Sep;119(9):1345-53.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0124-8146201100010000300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12 Salt AT, Wade AM, Proffitt R, Heavens S, Sonksen PM. <i>The Sonksen logMAR Test of Visual Acuity: I. Testability and reliability. </i>J AAPOS2007 Dec;11(6):589-96.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0124-8146201100010000300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13 Savage HI, Lee HH, Zaetta D, Olszowy R, Hamburger E, Weissman M, et al. <i>Pediatric Amblyopia Risk Investigation Study (PARIS). </i>Am J Ophthalmol2005 Dec;140(6):1007-13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0124-8146201100010000300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14 Dobson V, Maguire M, Orel-Bixler D, Quinn G, Ying GS. <i>Visual acuity results in school-aged children and adults: Lea Symbols chart versus Bailey-Lovie chart. </i>Optom Vis Sci2003 Sep;80(9):650-4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0124-8146201100010000300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15 Dobson V, Clifford-Donaldson CE, Miller JM, Garvey KA, Harvey EM. <i>A comparison of Lea Symbol vs ETDRS letter distance visual acuity in a population of young children with a high prevalence of astigmatism. </i>J AAPOS2009 Jun;13(3):253-7.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0124-8146201100010000300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16 Becker RH, Hubsch SH, Graf MH, Kaufmann H. <i>Preliminary report: examination of young children with Lea symbols. </i>Strabismus2000 Sep;8(3):209-13.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0124-8146201100010000300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17 Becker R, Hubsch S, Graf MH, Kaufmann H. <i>Examination of young children with Lea symbols. </i>Br J Ophthalmol2002 May;86(5):513-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0124-8146201100010000300017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18 Ruttum MS, Dahlgren M. <i>Comparison of the HOTV and Lea symbols visual acuity tests in patients with amblyopia. </i>J Pediatr Ophthalmol Strabismus2006 May-Jun;43(3):157-60.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0124-8146201100010000300018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19 Vision in Preschoolers Study G. <i>Effect of Age Using Lea Symbols or HOTV for Preschool Vision Screening. </i>Optom Vis Sci2010;87:87-95.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0124-8146201100010000300019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20 Hartmann EE. <i>Preschool vision screening: Maternal and Child Health Bureau and National Eye Institute Task Force on Vision Screening in the Preschool Child. </i>Optom Vis Sci2001 Feb;78(2):122-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0124-8146201100010000300020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21 P&eacute;rez M. D. Rodr&iacute;guez M. M. Gil L. J. Ram&iacute;rez R.G. Tama&ntilde;o de la muestra &#91;CD-ROM&#93; Versi&oacute;n 1.1, Bogot&aacute;-Colombia. 2005.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0124-8146201100010000300021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22 Bailey IL. Visual Acuity. En: Benjamin WM. Borish's Clinical Refraction. Second Edition. St Louis Missouri: Butterworth-Heinemann Elsevier; 2006. p. 217-246.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0124-8146201100010000300022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23 Holladay JM. <i>Proper method for calculating average visual acuity. </i>J Refrac. Sur1997; 13:388-391.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0124-8146201100010000300023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24 Myers VS, Gidlewski N, Quinn GE, Miller D, Dobson V. <i>Distance and near visual acuity, contrast sensitivity, and visual fields of 10-year-old children. </i>Arch Ophthalmol1999 Jan;117(1):94-9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0124-8146201100010000300024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25 Cepeda MS, P&eacute;rez A. <i>Estudios de Concordancia: Intercambiabilidad En Sistemas De Medici&oacute;n. </i>En: Ruiz Morales A, Morillo Zarate LE. Epidemiolog&iacute;a Cl&iacute;nica Investigaci&oacute;n Cl&iacute;nica Aplicada. Bogot&aacute; D.C.: Editorial M&eacute;dica Panamericana. 2005. p. 293-307.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0124-8146201100010000300025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26 Bland JM, Altman DG. <i>Measuring agreement in method comparison studies. </i>Stat Methods Med Res1999 Jun;8(2):135-60.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0124-8146201100010000300026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>27 Schmidt P, Maguire M, Dobson V, Quinn G, Ciner E, Cyert L, et al. <i>Comparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision In Preschoolers Study. </i>Ophthalmology2004 Apr;111(4):637-50.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0124-8146201100010000300027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>28 Bailey IL, Bullimore MA, Raasch TW, Taylor HR. <i>Clinical grading and the effects of scaling. </i>Invest Ophthalmol Vis Sci1991 Feb;32(2):422-32.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0124-8146201100010000300028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>29 Altman, D. Bland J. <i>Measurment in Medicine: the Analysis of Method Comparison Studies. </i>The Statisticians1983;32: 307-317.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0124-8146201100010000300029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30 Manny RE, Hussein M, Gwiazda J, Marsh-Tootle W. Repeatability of ETDRS visual acuity in children. Invest Ophthalmol Vis Sci2003 Aug;44(8):3294-300.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0124-8146201100010000300030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>31 Shah N, Laidlaw DA, Brown G, Robson C. <i>Effect of letter separation on computerised visual acuity measurements: comparison with the gold standard Early Treatment Diabetic Retinopathy Study (ETDRS) chart. </i>Ophthalmic Physiol Opt Mar;30(2):200-3.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0124-8146201100010000300031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bailey]]></surname>
<given-names><![CDATA[IL]]></given-names>
</name>
<name>
<surname><![CDATA[Lovie]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New design principles for visual acuity letter charts]]></article-title>
<source><![CDATA[Am J Optom Physiol Opt]]></source>
<year>1976</year>
<month> N</month>
<day>ov</day>
<volume>53</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>740-5</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ferris]]></surname>
<given-names><![CDATA[FL, 3rd]]></given-names>
</name>
<name>
<surname><![CDATA[Kassoff]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bresnick]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
<name>
<surname><![CDATA[Bailey]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New visual acuity charts for clinical research]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>1982</year>
<month> J</month>
<day>ul</day>
<volume>94</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>91-6</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pandit]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Testing acuity of vision in general practice: reaching recommended standard]]></article-title>
<source><![CDATA[BMJ]]></source>
<year>1994</year>
<month> N</month>
<day>ov</day>
<volume>309</volume>
<numero>6966</numero>
<issue>6966</issue>
<page-range>1408</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Currie]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Bhan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pepper]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability of Snellen charts for testing visual acuity for driving: prospective study and postal questionnaire]]></article-title>
<source><![CDATA[BMJ]]></source>
<year>2000</year>
<month> O</month>
<day>ct</day>
<volume>321</volume>
<numero>7267</numero>
<issue>7267</issue>
<page-range>990-2</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lovie-Kitchin]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Validity and reliability ofvisual acuity measurements]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>1988</year>
<volume>8</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>363-70</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[León]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Estrada]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Prueba piloto para determinar la reproducibilidad de la carta Snellen al evaluar la agudeza visual en sujetos jóvenes]]></article-title>
<source><![CDATA[Ciencia y tecnología para la salud visual y ocular]]></source>
<year>2009</year>
<volume>7</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>13-24</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[LI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A concordance correlation coefficient to evaluate reproducibility]]></article-title>
<source><![CDATA[Biometrics]]></source>
<year>1989</year>
<month> M</month>
<day>ar</day>
<volume>45</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>255-68</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mocan]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Najera-Covarrubias]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wright]]></surname>
<given-names><![CDATA[KW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of visual acuity levels in pediatric patients with amblyopia using Wright figures, Allen optotypes, and Snellen letters]]></article-title>
<source><![CDATA[J AAPOS]]></source>
<year>2005</year>
<month> F</month>
<day>eb</day>
<volume>9</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>48-52</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hyvarinen]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Nasanen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Laurinen]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New visual acuity test forpre-school children]]></article-title>
<source><![CDATA[Acta Ophthalmol (Copenh)]]></source>
<year>1980</year>
<month> A</month>
<day>ug</day>
<volume>58</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>507-11</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McGraw]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
<name>
<surname><![CDATA[Winn]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Gray]]></surname>
<given-names><![CDATA[LS]]></given-names>
</name>
<name>
<surname><![CDATA[Elliott]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improving the reliability of visual acuity measures in young children]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt]]></source>
<year>2000</year>
<month> M</month>
<day>ay</day>
<volume>20</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>173-84</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Beck]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[Repka]]></surname>
<given-names><![CDATA[MX]]></given-names>
</name>
<name>
<surname><![CDATA[Leske]]></surname>
</name>
<name>
<surname><![CDATA[Kraker]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
<name>
<surname><![CDATA[Blair]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The amblyopia treatment study visual acuity testing protocol]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>2001</year>
<month> S</month>
<day>ep</day>
<volume>119</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1345-53</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Salt]]></surname>
<given-names><![CDATA[AT]]></given-names>
</name>
<name>
<surname><![CDATA[Wade]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Proffitt]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Heavens]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sonksen]]></surname>
<given-names><![CDATA[PM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Sonksen logMAR Test of Visual Acuity: I. Testability and reliability]]></article-title>
<source><![CDATA[J AAPOS]]></source>
<year>2007</year>
<month> D</month>
<day>ec</day>
<volume>11</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>589-96</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savage]]></surname>
<given-names><![CDATA[HI]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[HH]]></given-names>
</name>
<name>
<surname><![CDATA[Zaetta]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Olszowy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hamburger]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Weissman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pediatric Amblyopia Risk Investigation Study (PARIS)]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2005</year>
<month> D</month>
<day>ec</day>
<volume>140</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1007-13</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Maguire]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Orel-Bixler]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Quinn]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Ying]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Visual acuity results in school-aged children and adults: Lea Symbols chart versus Bailey-Lovie chart]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2003</year>
<month> S</month>
<day>ep</day>
<volume>80</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>650-4</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Clifford-Donaldson]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Garvey]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Harvey]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of Lea Symbol vs ETDRS letter distance visual acuity in a population of young children with a high prevalence of astigmatism]]></article-title>
<source><![CDATA[J AAPOS]]></source>
<year>2009</year>
<month> J</month>
<day>un</day>
<volume>13</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>253-7</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Becker]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Hubsch]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[Graf]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preliminary report: examination of young children with Lea symbols]]></article-title>
<source><![CDATA[Strabismus]]></source>
<year>2000</year>
<month> S</month>
<day>ep</day>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>209-13</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Becker]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hubsch]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Graf]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Examination of young children with Lea symbols]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2002</year>
<month> M</month>
<day>ay</day>
<volume>86</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>513-6</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruttum]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Dahlgren]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the HOTV and Lea symbols visual acuity tests in patients with amblyopia]]></article-title>
<source><![CDATA[J Pediatr Ophthalmol Strabismus]]></source>
<year>2006</year>
<month> M</month>
<day>ay</day>
<volume>43</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>157-60</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<collab>Vision in Preschoolers Study G</collab>
<article-title xml:lang="en"><![CDATA[Effect of Age Using Lea Symbols or HOTV for Preschool Vision Screening]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2010</year>
<volume>87</volume>
<page-range>87-95</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hartmann]]></surname>
<given-names><![CDATA[EE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preschool vision screening: Maternal and Child Health Bureau and National Eye Institute Task Force on Vision Screening in the Preschool Child]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2001</year>
<month> F</month>
<day>eb</day>
<volume>78</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>122-6</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[M. D]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[M. M]]></given-names>
</name>
<name>
<surname><![CDATA[Gil]]></surname>
<given-names><![CDATA[L. J]]></given-names>
</name>
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[R.G]]></given-names>
</name>
</person-group>
<source><![CDATA[Tamaño de la muestra &#91;CD-ROM&#93; Versión 1.1]]></source>
<year>2005</year>
<publisher-loc><![CDATA[Bogotá^eColombia Colombia]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bailey]]></surname>
<given-names><![CDATA[IL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Visual Acuity]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Benjamin]]></surname>
<given-names><![CDATA[WM]]></given-names>
</name>
</person-group>
<source><![CDATA[Borish's Clinical Refraction]]></source>
<year>2006</year>
<edition>Second Edition</edition>
<page-range>217-246</page-range><publisher-loc><![CDATA[St Louis Missouri ]]></publisher-loc>
<publisher-name><![CDATA[Butterworth-Heinemann Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holladay]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Proper method for calculating average visual acuity]]></article-title>
<source><![CDATA[J Refrac. Sur]]></source>
<year>1997</year>
<volume>13</volume>
<page-range>388-391</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Myers]]></surname>
<given-names><![CDATA[VS]]></given-names>
</name>
<name>
<surname><![CDATA[Gidlewski]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Quinn]]></surname>
<given-names><![CDATA[GE]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Distance and near visual acuity, contrast sensitivity, and visual fields of 10-year-old children]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>1999</year>
<month> J</month>
<day>an</day>
<volume>117</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>94-9</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cepeda]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudios de Concordancia: Intercambiabilidad En Sistemas De Medición]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Ruiz Morales]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Morillo Zarate]]></surname>
<given-names><![CDATA[LE]]></given-names>
</name>
</person-group>
<source><![CDATA[Epidemiología Clínica Investigación Clínica Aplicada]]></source>
<year>2005</year>
<page-range>293-307</page-range><publisher-loc><![CDATA[Bogotá D.C. ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Médica Panamericana]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bland]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Altman]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measuring agreement in method comparison studies]]></article-title>
<source><![CDATA[Stat Methods Med Res]]></source>
<year>1999</year>
<month> J</month>
<day>un</day>
<volume>8</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>135-60</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schmidt]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Maguire]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Quinn]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Ciner]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Cyert]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision In Preschoolers Study]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2004</year>
<month> A</month>
<day>pr</day>
<volume>111</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>637-50</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bailey]]></surname>
<given-names><![CDATA[IL]]></given-names>
</name>
<name>
<surname><![CDATA[Bullimore]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Raasch]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[HR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical grading and the effects of scaling]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>1991</year>
<month> F</month>
<day>eb</day>
<volume>32</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>422-32</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Altman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bland]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurment in Medicine: the Analysis of Method Comparison Studies]]></article-title>
<source><![CDATA[The Statisticians]]></source>
<year>1983</year>
<volume>32</volume>
<page-range>307-317</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manny]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Hussein]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gwiazda]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Marsh-Tootle]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Repeatability of ETDRS visual acuity in children]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2003</year>
<month> A</month>
<day>ug</day>
<volume>44</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>3294-300</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Laidlaw]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Robson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of letter separation on computerised visual acuity measurements: comparison with the gold standard Early Treatment Diabetic Retinopathy Study (ETDRS) chart]]></article-title>
<source><![CDATA[Ophthalmic Physiol Opt Mar]]></source>
<year></year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>200-3</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>