<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1692-3324</journal-id>
<journal-title><![CDATA[Revista Ingenierías Universidad de Medellín]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. ing. univ. Medellín]]></abbrev-journal-title>
<issn>1692-3324</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Medellín]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1692-33242019000200051</article-id>
<article-id pub-id-type="doi">10.22395/rium.v18n35a4</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Confort térmico en viviendas de Medellín]]></article-title>
<article-title xml:lang="en"><![CDATA[Thermal Comfort in Residential Housing in Medellin]]></article-title>
<article-title xml:lang="pt"><![CDATA[Conforto térmico de habitações em Medellín]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Soto-Estrada]]></surname>
<given-names><![CDATA[Engelberth]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Álvarez-Carrascal]]></surname>
<given-names><![CDATA[Fernanda]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gómez-Lizarazo]]></surname>
<given-names><![CDATA[Jairo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valencia-Montoya]]></surname>
<given-names><![CDATA[Daniel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad EIA  ]]></institution>
<addr-line><![CDATA[Envigado ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad EIA  ]]></institution>
<addr-line><![CDATA[Envigado ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad EIA  ]]></institution>
<addr-line><![CDATA[Envigado ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Universidad EIA  ]]></institution>
<addr-line><![CDATA[Envigado ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2019</year>
</pub-date>
<volume>18</volume>
<numero>35</numero>
<fpage>51</fpage>
<lpage>68</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S1692-33242019000200051&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S1692-33242019000200051&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S1692-33242019000200051&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen El ambiente térmico en una edificación influye en la salud, el bienestar y la productividad de las personas, así como en el consumo energético. La importancia del confort térmico en las edificaciones se reconoce desde hace décadas, no obstante, este aspecto es aún incipiente en la industria de la construcción colombiana, sobre todo en proyectos de vivienda. En esta investigación se analizó el desempeño térmico de tres tipos de vivienda comunes en la ciudad de Medellín. Para ello se calculó la temperatura operativa, el voto medio estimado (PMV) y el porcentaje estimado de insatisfechos (PPD), de acuerdo con la norma ISO 7730:2005. Los resultados mostraron que la inercia térmica de dos de los tres tipos de vivienda examinados no es suficiente para ofrecer un confort térmico adecuado, a pesar del clima templado del Valle de Aburrá. Estos resultados alertan sobre la vulnerabilidad de la población urbana en Colombia ante fluctuaciones extremas de temperatura.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract The indoor thermal environment of buildings influences people's health, well-being and productivity, as well as energy consumption. The importance of thermal comfort in buildings has been recognized for decades. However, this aspect is still incipient in the Colombian construction industry, especially in housing projects. In this research, the thermal performance of three common housing types in the city of Medellin was analyzed. To do this, the operative temperature, the predicted mean vote (PMV) and the predicted percentage of dissatisfied (PPD) were calculated in accordance with ISO 7730:2005. The results showed that the thermal inertia of two of the three types of housing examined was insufficient to offer adequate thermal conditions, despite the temperate climate of the Aburra Valley. These results warn about the vulnerability of urban population in Colombia to extreme temperature fluctuations.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Resumo O ambiente térmico em uma construção influencia na saúde, no bem-estar e na produtividade das pessoas, bem como no consumo energético. A importância do conforto térmico nas edificações é reconhecida há décadas, não obstante, esse aspecto ainda é incipiente na indústria da construção colombiana, sobretudo em projetos de habitação. Nesta pesquisa, o desempenho térmico de três tipos de habitação comuns na cidade de Medellín foi analisado. Para isso, calculou-se a temperatura operativa, o voto médio estimado (PMV) e a porcentagem estimada de insatisfeitos (PPD), de acordo com a norma ISO 7730:2005. Os resultados mostraram que a inércia térmica de dois dos três tipos de habitação examinados não é suficiente para oferecer um conforto térmico adequado, apesar do clima ameno do Valle de Aburrá. Esses resultados alertam sobre a vulnerabilidade da população urbana na Colômbia ante oscilações extremas de temperatura.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[confort térmico]]></kwd>
<kwd lng="es"><![CDATA[temperatura operativa]]></kwd>
<kwd lng="es"><![CDATA[temperatura radiante]]></kwd>
<kwd lng="es"><![CDATA[PMV]]></kwd>
<kwd lng="es"><![CDATA[PPD]]></kwd>
<kwd lng="en"><![CDATA[thermal comfort]]></kwd>
<kwd lng="en"><![CDATA[operative temperature]]></kwd>
<kwd lng="en"><![CDATA[radiant temperature]]></kwd>
<kwd lng="en"><![CDATA[PMV]]></kwd>
<kwd lng="en"><![CDATA[PPD]]></kwd>
<kwd lng="pt"><![CDATA[conforto térmico]]></kwd>
<kwd lng="pt"><![CDATA[temperatura operativa]]></kwd>
<kwd lng="pt"><![CDATA[temperatura radiante]]></kwd>
<kwd lng="pt"><![CDATA[PMV]]></kwd>
<kwd lng="pt"><![CDATA[PPD]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>[1]</label><nlm-citation citation-type="book">
<collab>Thermal Environmental Conditions forHuman Occupancy</collab>
<source><![CDATA[ANSI/Ashrae Standard 55-2017]]></source>
<year>2017</year>
<publisher-name><![CDATA[American Society of Heating, Refrigerating and Air-Conditioning Engineers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>[2]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vernon]]></surname>
<given-names><![CDATA[H. M]]></given-names>
</name>
<name>
<surname><![CDATA[Warner]]></surname>
<given-names><![CDATA[C. G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The influence of the humidity of the air on capacity for work at high temperatures]]></article-title>
<source><![CDATA[Journal of IndustrialHygiene]]></source>
<year>1932</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>431-63</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>[3]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fanger]]></surname>
<given-names><![CDATA[P. O]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Calculations of thermal comfort: introduction of a basic comfort equation]]></article-title>
<source><![CDATA[Ashrae Transactions]]></source>
<year>1967</year>
<volume>73</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1-4</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>[4]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gagge]]></surname>
<given-names><![CDATA[A. P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An effective temperature scale based on a simple model of human physiological regulatory response]]></article-title>
<source><![CDATA[Ashrae Transactions]]></source>
<year>1971</year>
<volume>77</volume>
<page-range>247-62</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>[5]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berglund]]></surname>
<given-names><![CDATA[L. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Gobelets]]></surname>
<given-names><![CDATA[A. P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Subjective human response to low-level air current and asymmetric radiation]]></article-title>
<source><![CDATA[Ashrae Transactions]]></source>
<year>1987</year>
<volume>93</volume>
<page-range>497-523</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>[6]</label><nlm-citation citation-type="">
<collab>Ergonomía del ambiente térmico</collab>
<source><![CDATA[Aenor, Asociación Española de Normalización y Certificación, Estándar UNE-EN ISO 7730]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B7">
<label>[7]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frederick]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Rohles]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Temperature and temperament. A psychologist looks at comfort]]></article-title>
<source><![CDATA[Ashrae Journal]]></source>
<year>2007</year>
<volume>49</volume>
<page-range>14-22</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>[8]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[French]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Sustainability as promoting well-being: psychological dimensions of thermal comfort]]></source>
<year>2010</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>[9]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fabbri]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<source><![CDATA[Indoor thermal comfort perception. A questionnaire approach focusing on children]]></source>
<year>2015</year>
<page-range>147</page-range><publisher-loc><![CDATA[Switzerland ]]></publisher-loc>
<publisher-name><![CDATA[Springer International Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>[10]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gagge]]></surname>
<given-names><![CDATA[A. P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The linearity criterion as applied to partitional calorimetry]]></article-title>
<source><![CDATA[American Journal of Physiology]]></source>
<year>1936</year>
<volume>116</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>656-68</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>[11]</label><nlm-citation citation-type="journal">
<collab>CCCS</collab>
<article-title xml:lang=""><![CDATA[Consejo Colombiano de Construcción Sostenible. La vivienda sostenible se abre espacio en el país]]></article-title>
<source><![CDATA[Revista Portafolio]]></source>
<year>2017</year>
</nlm-citation>
</ref>
<ref id="B12">
<label>[12]</label><nlm-citation citation-type="">
<collab>Eronomics of the termal environment - Instruments for measuring physical quantities</collab>
<source><![CDATA[International Organization for Standarization, Estándar ISO 7726]]></source>
<year>1998</year>
</nlm-citation>
</ref>
<ref id="B13">
<label>[13]</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández-García]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Fundamentos físicos y métodos de evaluación del confort climático en los estudios de bioclimatología humana]]></source>
<year>2000</year>
<conf-name><![CDATA[ presentado en VI Reunión Nacional de Climatología]]></conf-name>
<conf-loc>Santiago de Compostela </conf-loc>
</nlm-citation>
</ref>
<ref id="B14">
<label>[14]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ashrae]]></surname>
</name>
</person-group>
<source><![CDATA[2001 Ashrae Handbook: fundamentals]]></source>
<year>2001</year>
<page-range>544</page-range><publisher-loc><![CDATA[Atlanta ]]></publisher-loc>
<publisher-name><![CDATA[American Society of Heating, Refrigerating and Air-Conditioning Engineers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B15">
<label>[15]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Verbeke]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Audenaert]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Thermal inertia in buildings: A review of impacts across climate and building use]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2018</year>
<volume>82</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>2300-18</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>[16]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ulgen]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Experimental and theoretical investigation of effects of wall's thermophysical properties on time lag and decrement factor]]></article-title>
<source><![CDATA[Energy and Buildings]]></source>
<year>2002</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>273-8</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>[17]</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tuohy]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Thermal mass, insulation and ventilation in sustainable housing - an investigation across climate and occupancy]]></source>
<year>2005</year>
<conf-name><![CDATA[ presentado en IX International IBPSA Conference]]></conf-name>
<conf-loc>Montreal </conf-loc>
</nlm-citation>
</ref>
<ref id="B18">
<label>[18]</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ferrari]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving]]></source>
<year>2007</year>
<conf-name><![CDATA[ presentado en 2nd Palenc Conference and 28th AIVC Conference on Building Low Energy Cooling and Advanced Ventilation Technologies in the 21 st Century]]></conf-name>
<conf-loc>Creta </conf-loc>
</nlm-citation>
</ref>
<ref id="B19">
<label>[19]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Detailed energy saving performance analyses on thermal mass walls demonstrated in a zero energy house]]></article-title>
<source><![CDATA[Energy and Buildings]]></source>
<year>2009</year>
<volume>41</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>303-10</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>[20]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scott]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Beating the Heat]]></source>
<year>2006</year>
<publisher-name><![CDATA[Nasa Earth Observatory]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<label>[21]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Campbell-Lendrum]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Corvalán]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Climate change and developing-country cities: implications for environmental health and equity]]></article-title>
<source><![CDATA[Journal of Urban Health]]></source>
<year>2007</year>
<volume>84</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>109-15</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
