<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1909-9762</journal-id>
<journal-title><![CDATA[Revista Ingeniería Biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. ing. biomed.]]></abbrev-journal-title>
<issn>1909-9762</issn>
<publisher>
<publisher-name><![CDATA[Fondo Editorial EIA, Escuela de Ingeniería de Antioquia EIA-, Universidad CES]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1909-97622010000100008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[EXOESQUELETOS PARA POTENCIAR LAS CAPACIDADES HUMANAS Y APOYAR LA REHABILITACIÓN]]></article-title>
<article-title xml:lang="en"><![CDATA[EXOSKELETONS TO ENHANCE HUMAN CAPABILITIES AND SUPPORT REHABILITATION: A STATE OF THE ART]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Chávez Cardona]]></surname>
<given-names><![CDATA[Manuel Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Spitia]]></surname>
<given-names><![CDATA[Felipe]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Baradica López]]></surname>
<given-names><![CDATA[Asfur]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad del Valle Escuela de Ingeniería Eléctrica y Electrónica Grupo de Investigación PSI]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad del Valle Escuela de Ingeniería Eléctrica y Electrónica Grupo de Investigación PSI]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<volume>4</volume>
<numero>7</numero>
<fpage>63</fpage>
<lpage>73</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S1909-97622010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S1909-97622010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S1909-97622010000100008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El presente artículo presenta una revisión bibliográfica sobre el diseño de exoesqueletos y las diferentes aplicaciones que estos pueden tener en la vida humana. Se exponen diferentes desarrollos, resaltando las partes más importantes de cada uno y prestando especial atención al área de la ingeniería electrónica presente en estas estructuras. Además, se realiza un agrupamiento de los diseños, dependiendo de la zona corporal para la cual se ha construido el exoesqueleto o de la finalidad del estudio realizado. Finalmente, se presentan desarrollos y estudios que buscan utilizar las señales mioeléctricas como parte fundamental del sistema exoesquelético.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[This paper presents a literature review about exoskeletons and their applications in human life. Different developments highlighting the most important parts of each of them, and paying particular attention to the area of electronic engineering related to these structures, are shown. Also, a grouping of the different kinds of structures is made depending on the area of the human body to which the exoskeleton was intended to or depending on the purpose of the research. Finally, various studies and developments which use mioelectric signals as a fundamental part of the system are presented.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Aplicaciones médicas]]></kwd>
<kwd lng="es"><![CDATA[Aplicaciones militares]]></kwd>
<kwd lng="es"><![CDATA[Electromiografía]]></kwd>
<kwd lng="es"><![CDATA[Exoesqueleto]]></kwd>
<kwd lng="es"><![CDATA[Grados de libertad]]></kwd>
<kwd lng="es"><![CDATA[Sensores]]></kwd>
<kwd lng="es"><![CDATA[Sistema de control]]></kwd>
<kwd lng="en"><![CDATA[Medical applications]]></kwd>
<kwd lng="en"><![CDATA[Military applications]]></kwd>
<kwd lng="en"><![CDATA[Electromyography]]></kwd>
<kwd lng="en"><![CDATA[Exoskeleton]]></kwd>
<kwd lng="en"><![CDATA[Degrees of freedom]]></kwd>
<kwd lng="en"><![CDATA[Sensors]]></kwd>
<kwd lng="en"><![CDATA[Control systems]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">          <p align="center"><font size="4"><b>EXOESQUELETOS PARA POTENCIAR LAS CAPACIDADES HUMANAS Y APOYAR LA REHABILITACI&Oacute;N</b></font></p>     <p align="center"><font size="3"><b>EXOSKELETONS TO ENHANCE  HUMAN CAPABILITIES AND SUPPORT REHABILITATION: A STATE OF THE ART</b></font></p>     <p>&nbsp;</p>     <p><b>Manuel Alejandro Ch&aacute;vez Cardona<sup>1,2</sup>,  Felipe Rodr&iacute;guez Spitia<sup>1</sup>,  Asfur Baradica L&oacute;pez<sup>1</sup></b></p>          <p><i>1 Escuela de Ingenier&iacute;a El&eacute;ctrica y Electr&oacute;nica,  Grupo de Investigaci&oacute;n PSI,  Universidad del Valle,  Colombia.    <br> 2 Direcci&oacute;n para correspondencia: <a href="mailto:chavezmanuel@gmail.com">chavezmanuel@gmail.com</a>.</i></p>     <p>Recibido 19 de febrero de 2010. Aceptado 24 de mayo de 2010</p> <hr size="1" />              <p>&nbsp;</p>     <p><b><font size="3">RESUMEN</font></b></p>     ]]></body>
<body><![CDATA[<p>El presente art&iacute;culo presenta una revisi&oacute;n bibliogr&aacute;fica sobre el dise&ntilde;o de exoesqueletos y las diferentes aplicaciones   que estos pueden tener en la vida humana. Se exponen diferentes desarrollos,  resaltando las partes m&aacute;s importantes de cada uno y   prestando especial atenci&oacute;n al &aacute;rea de la ingenier&iacute;a electr&oacute;nica presente en estas estructuras. Adem&aacute;s,  se realiza un agrupamiento   de los dise&ntilde;os,  dependiendo de la zona corporal para la cual se ha construido el exoesqueleto o de la finalidad del estudio realizado.   Finalmente,  se presentan desarrollos y estudios que buscan utilizar las se&ntilde;ales mioel&eacute;ctricas como parte fundamental del sistema exoesquel&eacute;tico.</p>          <p><font size="3"><b>PALABRAS CLAVE</b></font>: Aplicaciones m&eacute;dicas,  Aplicaciones militares,  Electromiograf&iacute;a,  Exoesqueleto,  Grados de libertad,  Sensores,  Sistema de control.</p>  <hr size="1" />              <p>&nbsp;</p>     <p><font size="3"><b>ABSTRACT</b></font></p>     <p>This paper presents a literature review about exoskeletons and their applications in human life. Different   developments highlighting the most important parts of each of them,  and paying particular attention to the area of electronic   engineering related to these structures,  are shown. Also,  a grouping of the different kinds of structures is made depending on the   area of the human body to which the exoskeleton was intended to or depending on the purpose of the research. Finally,  various studies and developments which use mioelectric signals as a fundamental part of the system are presented.</p>     <p><font size="3"><b>KEY WORDS</b></font>: Medical applications,  Military applications,  Electromyography,  Exoskeleton,  Degrees of freedom,  Sensors,  Control systems.</p>  <hr size="1" />           <p>&nbsp;</p>       <p><font size="3"><b>I. INTRODUCCI&Oacute;N</b></font></p>          <p>La tecnolog&iacute;a de hoy se ha visto inmersa en casi todos   los campos de trabajo,  como el militar,  la salud,  el   ocio,  entre otros,  siendo la medicina uno de los m&aacute;s   beneficiados,  debido a que estas tendencias impulsan el   desarrollo de herramientas especializadas que facilitan el   trabajo del m&eacute;dico y la recuperaci&oacute;n de los pacientes. Una   de las herramientas que buscan mejorar la calidad de vida   de las personas,  son los exoesqueletos. Un exoesqueleto   es,  b&aacute;sicamente,  una estructura para ser usada sobre el   cuerpo humano a manera de prenda de vestir,  tal como   lo describe el t&eacute;rmino ingl&eacute;s "wearable robots",  que sirve   como apoyo y se usa para asistir los movimientos y/o   aumentar las capacidades del cuerpo humano. Pueden ser   estructuras pasivas o activas,  es decir que contengan o no   actuadores para el movimiento y por lo tanto necesiten   o no un sistema de control asociado al accionamiento de   dichos actuadores. La gran mayor&iacute;a de los exoesqueletos,    como desarrollos para la medicina,  se adapta al cuerpo   con sistemas inteligentes de procesamiento y sensado para   la toma de decisiones en la ejecuci&oacute;n de alguna funci&oacute;n   por medio de actuadores,  con el fin de realizar una tarea   previamente definida. El dise&ntilde;o de estos mecanismos,  se concibe con la ayuda de distintas disciplinas como la   medicina,  la electr&oacute;nica,  la f&iacute;sica y la mec&aacute;nica. Dentro del   campo de la electr&oacute;nica,  se reconocen a la instrumentaci&oacute;n   electr&oacute;nica y al control como partes fundamentales del   sistema; la instrumentaci&oacute;n,  se encarga de recolectar la   informaci&oacute;n &uacute;til para ser enviada a un procesador central,    el cual contiene las estrategias de control necesarias   para tomar una decisi&oacute;n de acuerdo con la informaci&oacute;n   recibida. Esta informaci&oacute;n debe ser sumamente confiable   y los principios usados deben ser los apropiados para cada   aplicaci&oacute;n.</p>     <p>En la electr&oacute;nica de exoesqueletos,  se distinguen   distintas formas de realizar la adquisici&oacute;n de la   informaci&oacute;n y distintas estrategias de control que se   adoptan dependiendo de cada desarrollo,  teniendo en   cuenta que lo acordado y lo implementado siempre tienen   que estar en concordancia con los desarrollos de las dem&aacute;s   &aacute;reas aplicadas a la construcci&oacute;n del exoesqueleto.</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><b><font size="3">II. EXTREMIDADES SUPERIORES</font></b> </p>     <p>A partir de esta investigaci&oacute;n,  es posible afirmar   que gran parte de los desarrollos alrededor de los   exoesqueletos se ha concentrado en solucionar los   problemas relacionados con las extremidades inferiores   del cuerpo humano. Sin embargo,  no dejan de existir los   esfuerzos que se concentran tambi&eacute;n en las extremidades   superiores,  como los brazos y manos,  incluyendo las   articulaciones del codo,  el hombro,  las mu&ntilde;ecas y los   dedos. A continuaci&oacute;n,  en los numerales 2.1 y 2.2,  se   describen algunos de los trabajos realizados en estas &aacute;reas.</p>     <p><i><font size="3">2.1 Mano:</font></i></p>     <p>En cuanto a la rehabilitaci&oacute;n de los dedos,  Ju Wang,    Jiting Li,  Yuru Zhang y Shuang Wang &#91;<a href="#1">1</a>&#93; presentan   un exoesqueleto con cuatro grados de libertad para la   rehabilitaci&oacute;n del dedo &iacute;ndice. El dispositivo puede   generar movimiento bidireccional (flexi&oacute;n-extensi&oacute;n)   para todas las articulaciones del dedo y es ajustable   para varios tama&ntilde;os de mano. Se utilizan sensores de   fuerza Flexiforce&reg; y encoders junto al motor de DC   para medir la posici&oacute;n angular. La informaci&oacute;n recibida   de los sensores,  se utiliza para realizar el control del   exoesqueleto y evaluar y analizar los efectos de la   rehabilitaci&oacute;n. Tambi&eacute;n enfocados en la rehabilitaci&oacute;n,    Andreas Wege,  Konstantin Kondak,  y G&uuml;nter Hommel   &#91;<a href="#2">2</a>&#93;,  desarrollaron un exoesqueleto para la rehabilitaci&oacute;n de   la mano,  empezando con la construcci&oacute;n de un prototipo   mec&aacute;nico de cuatro grados de libertad,  el cual es movido   por una unidad actuadora y recibe informaci&oacute;n a trav&eacute;s   de sensores de efecto hall en cada articulaci&oacute;n de la   estructura; por medio de ecuaciones trigonom&eacute;tricas   y conociendo la longitud de cada segmento,  calculan   los &aacute;ngulos correspondientes a cada falange. Tambi&eacute;n   utilizan sensores de fuerza resistivos en las partes superior   e inferior de las falanges y sensores mioel&eacute;ctricos para   medir la actividad de algunos m&uacute;sculos de inter&eacute;s.</p>     <p>Por su lado,  Bobby L. Shields y otros autores,  en el   documento "<i>An anthropomorphic hand exoskeleton to   prevent astronaut hand fatigue during extravehicular   activities</i>" &#91;<a href="#3">3</a>&#93;,  presentan un prototipo,  tambi&eacute;n con   fines m&eacute;dicos,  pero esta vez con un enfoque preventivo.   El exoesqueleto mec&aacute;nico para la mano,  es dise&ntilde;ado   para encajar en la mano enguantada de un astronauta y   contrarrestar la rigidez del traje espacial presurizado. Los   movimientos de la mano se monitorean con un arreglo de   sensores de presi&oacute;n ubicados entre el exoesqueleto y la   mano y,  por medio de un microcontrolador,  se aplican los   comandos del controlador a un arreglo motor controlado   por PWM.</p>     <p>Otros prototipos,  se construyen con la finalidad   de crear ambientes virtuales con los cuales se pueda   interactuar. En esta &aacute;rea,  Tatsuya Koyama,  Ikuo Yamano,    Kenjiro Takemura y Takashi Maeno &#91;<a href="#4">4</a>&#93;,  proponen una   nueva metodolog&iacute;a para sistemas maestro-esclavo,  usando   realimentaci&oacute;n pasiva de fuerza,  en su art&iacute;culo "<i>Multifingered   exoskeleton haptic device using passive force   feedback for dexterous teleoperation</i>". Construyen un   exoesqueleto maestro para la mano que cuenta con tres   dedos de cuatro grados de libertad (GDL) cada uno (doce   GDL en total). Utilizan realimentaci&oacute;n de fuerza y un   algoritmo de control que usa embragues electromagn&eacute;ticos   y elementos el&aacute;sticos. Su funcionamiento se basa en   conmutar entre un control de fuerza y un control de   posici&oacute;n,  y esta conmutaci&oacute;n depende directamente de   si se est&aacute; en contacto con un objeto. Con el exoesqueleto   construido y la estrategia de control implementada,  se   dise&ntilde;a un sistema de realidad virtual para la mano. Se   usan platos de acr&iacute;lico,  potenci&oacute;metros y ejes de acr&iacute;lico   como componentes de enlace,  sensores de &aacute;ngulo y   elementos el&aacute;sticos respectivamente. Por esta misma l&iacute;nea,    se encuentra el exoesqueleto propuesto por Panagiotis   Stergiopoulos,  Philippe Fuchs y Claude Laurgeau,    quienes introducen un exoesqueleto de mano que permite   una extensi&oacute;n y flexi&oacute;n completas de los dedos &iacute;ndice   y pulgar &#91;<a href="#5">5</a>&#93;. Aplica una realimentaci&oacute;n bidireccional,  y   ofrece tres GDL para el dedo &iacute;ndice y cuatro GDL para   el pulgar. Utilizan motores de corriente directa,  cables de   transmisi&oacute;n y sensores de fuerza,  para medir la potencia   de los actuadores y la capacidad de fuerza de la mano. El   mecanismo se dise&ntilde;&oacute; para ser usado junto con un brazo   h&aacute;ptico (relativo al tacto) comercial de seis GDL,  con el   fin de permitir la simulaci&oacute;n de fuerzas externas.</p>     <p>El art&iacute;culo "<i>The rutgers master II-new design forcefeedback   glove</i>",  escrito por Mourad Bouzit,  Grigore Burdea y George Popescuy Rares Boian &#91;<a href="#6">6</a>&#93;,  describe   la construcci&oacute;n de otro exoesqueleto tipo guante que   interacciona con un ambiente virtual 3D en tiempo real;   se instrument&oacute; usando actuadores neum&aacute;ticos (servo   v&aacute;lvulas neum&aacute;ticas),  sensores de efecto hall para medir   el &aacute;ngulo y sensores de infrarrojo. Para el procesamiento   de la informaci&oacute;n,  utilizaron una placa Pentium a 233 Hz,    16 canales de entrada,  8 canales de salida,  bus PC104 para   la comunicaci&oacute;n de los sensores y una interfaz RS232   para comunicaci&oacute;n con el computador. Tambi&eacute;n con un   &eacute;nfasis en la realidad virtual,  el exoesqueleto expuesto   por B. H. Choi y H. R. Choi en el art&iacute;culo "<i>A semi-direct   drive hand exoskeleton using ultrasonic motor</i>" &#91;<a href="#7">7</a>&#93;,    consiste en un guante para sentir objetos en ambientes   virtuales usando motores ultras&oacute;nicos,  sensores de fuerza   y sensores para el movimiento angular,  convirtiendo la   se&ntilde;al de los sensores de fuerza al torque que debe generar   el motor. Por su parte,  Josep Amat y otros autores,  en su   art&iacute;culo "<i>Virtual exoskeleton for telemanipulation</i>" &#91;<a href="#8">8</a>&#93;,    combinan la realidad virtual con un exoesqueleto real,    creando un sistema con comunicaci&oacute;n hombre-m&aacute;quina   basado en visi&oacute;n. Este sistema,  est&aacute; dise&ntilde;ado para que un   computador o una unidad de control puedan ver y seguir   la posici&oacute;n de las manos de una persona,  y la intenci&oacute;n   es que dicho sistema sea utilizado como un exoesqueleto   virtual para tareas simples de tele-manipulaci&oacute;n,  donde se   tienen hasta cinco grados de libertad,  tres para la ubicaci&oacute;n   de la mu&ntilde;eca y dos para la orientaci&oacute;n del actuador.</p>     <p><i><font size="3">2.2 Brazo y antebrazo:</font></i></p>     <p>Muchos exoesqueletos se dise&ntilde;an tambi&eacute;n para   su aplicaci&oacute;n en los brazos humanos,  incluyendo las   articulaciones del codo (brazo-antebrazo) y el hombro.   En este campo,  existen desarrollos que ayudan en la   rehabilitaci&oacute;n de personas,  otros que brindan apoyo para   aumentar las capacidades humanas y tambi&eacute;n los que   permiten la interacci&oacute;n con ambientes virtuales para   m&uacute;ltiples prop&oacute;sitos.</p>     ]]></body>
<body><![CDATA[<p>El proyecto <i>EXOCAP</i> &#91;<a href="#9">9</a>&#93;,  desarrollado en Colombia,    muestra la elaboraci&oacute;n de software y hardware para   interaccionar con mundos de realidad virtual y realidad   aumentada,  con software de libre distribuci&oacute;n y tecnolog&iacute;a   disponible en el mercado colombiano. Se desarrolla un   exoesqueleto de brazo con el fin de probar la viabilidad del   dise&ntilde;o de un exoesqueleto completo,  utilizando aluminio   para construir la estructura,  sensores de rotaci&oacute;n y un   hardware basado en un conversor an&aacute;logo digital. En otra   regi&oacute;n de Colombia,  los ingenieros Jason Edwin Molina   y Juan Pablo Gonz&aacute;lez de la Universidad tecnol&oacute;gica de   Pereira &#91;<a href="#10">10</a>&#93;,  definen una forma para realizar un sistema   de control en un exoesqueleto con una estructura para el   brazo. Muestran c&oacute;mo hacer un sistema completo que   responda ante la referencia proveniente del humano y   se realiza una identificaci&oacute;n de par&aacute;metros del actuador   para finalmente proponer un sistema de control de fuerza   para la estructura mec&aacute;nica y el actuador el&eacute;ctrico.   Tambi&eacute;n en la Universidad Tecnol&oacute;gica de Pereira,    Jason Edwin Molina y &Aacute;lvaro &Aacute;ngel Orozco exponen   su trabajo "<i>Desarrollo de un sistema de control para   asistencia del movimiento humano tipo flexi&oacute;n extensi&oacute;n   del brazo,  para el desarrollo de exoesqueletos</i>" &#91;<a href="#11">11</a>&#93;.   Utilizan una metodolog&iacute;a que consiste en realizar un   sistema que contenga al humano y la m&aacute;quina dentro de   un mismo sistema,  intercambiando se&ntilde;ales de informaci&oacute;n   y potencia. Para realizar lo anterior,  plantean una red   neuronal como modelo del m&uacute;sculo,  la cual se ubica   dentro de los modelos macrosc&oacute;picos del mismo y es   entrenada bajo el paradigma <i>Backpropagation</i>.</p>     <p>Como en el caso del EXOCAP anteriormente   mencionado,  los ingenieros Wusheng Chou,  Tianmiao   Wang y Jing Xiao,  en su proyecto "<i>Haptic interaction with   virtual environment using an arm type exoskeleton device</i>"   &#91;<a href="#12">12</a>&#93;,  presentan un exoesqueleto de brazo de siete GDL,  que   interacciona con un entorno virtual en el cual se captura el   movimiento por medio de anillos deslizantes coaxiales que,    al realizar una rotaci&oacute;n,  miden su valor angular por medio   de sensores de &aacute;ngulo. Con los datos obtenidos,  calculan la   posici&oacute;n del exoesqueleto y se realiza una realimentaci&oacute;n   de fuerza para ser aplicada al brazo.</p>     <p>Otros exoesqueletos son usados con un enfoque   investigativo. Como ejemplo,  los investigadores Michael   Mistry,  Peyman Mohajerian y Stefan Schaal,  en el   proyecto "<i>Arm movement experiments with joint space   force fields using an exoskeleton robot</i>" &#91;<a href="#13">13</a>&#93;,  muestran   un exoesqueleto de brazo con siete GDL,  que elimina   las perturbaciones debido a la inercia y a la gravedad   por medio de una plataforma 3D experimental. Miden   la posici&oacute;n y el torque en cada articulaci&oacute;n,  a una tasa   de muestreo de 960Hz,  y calculan la velocidad y la   aceleraci&oacute;n a partir de posici&oacute;n. Implementan circuitos   de adecuaci&oacute;n y filtrado de la se&ntilde;al,  para eliminar los   ruidos generados por la derivaci&oacute;n de la misma. Para   medir la fuerza,  usan sensores <i>end effectors</i> ubicados en   las articulaciones,  y controladores Motorola PPC 603 que soportan tiempo real,  para el sistema de control.</p>     <p>La rehabilitaci&oacute;n de las extremidades superiores,    tambi&eacute;n es un tema de gran inter&eacute;s e importancia,  por lo   cual varios grupos de trabajo en el mundo han desarrollado   diferentes propuestas que buscan ayudar en el tema. En   el trabajo presentado por N.G. Tsagarakis y Darwin G.   Caldwell,  titulado "<i>A compliant exoskeleton for multiplanar   upper limb physiotherapy and training</i>",  muestran   un exoesqueleto para la rehabilitaci&oacute;n y entrenamiento   &#91;<a href="#14">14</a>&#93;. Este exoesqueleto cuenta con siete GDL y un peso inferior a los 2 kg. Este bajo peso se logra,  principalmente,    gracias al uso de una nueva l&iacute;nea de actuadores lineales   musculares de bajo peso. El exoesqueleto cuenta con   sensores de torque y posici&oacute;n,  y est&aacute; enfocado a la   fisioterapia y la arquitectura de control para entrenamiento   f&iacute;sico. Aportando tambi&eacute;n en el campo de la rehabilitaci&oacute;n,    la Universidad Militar Nueva Granada,  Bogot&aacute;,  ha   desarrollado un exoesqueleto que se basa en la repetici&oacute;n   de movimientos programados o movimientos aprendidos.   Este exoesqueleto cuenta con tres GDL y se controla a   trav&eacute;s de una interfaz de usuario en la cual programan las   trayectorias deseadas por el m&eacute;dico. Adicionalmente,  el   exoesqueleto puede aprender un movimiento realizado por   el fisioterapeuta para despu&eacute;s repetirlo. Tambi&eacute;n cuenta   con la posibilidad de almacenar los datos de cada paciente   &#91;<a href="#15">15</a>&#93;. Adem&aacute;s,  en Grecia,  Evangelos Papadopoulos y   Georgios Patsianis,  presentan un mecanismo con dos GDL   para la abducci&oacute;n frontal y lateral del miembro superior.   Realizan an&aacute;lisis de cinem&aacute;tica del mecanismo h&iacute;brido y   presentan un modelo CAD en 3D,  junto con un an&aacute;lisis   de elementos finitos (FEM,  por sus siglas en ingl&eacute;s) que   ilustra la estabilidad y durabilidad del exoesqueleto. Hasta   la fecha de la publicaci&oacute;n del art&iacute;culo,  el mecanismo   mencionado estaba en etapa de desarrollo y los autores   esperan que &eacute;ste le sirva a personas con atrofia muscular   o ayude a una recuperaci&oacute;n m&aacute;s r&aacute;pida de personas lesionadas &#91;<a href="#16">16</a>&#93;.</p>     <p>Los estudios en exoesqueletos con fines m&eacute;dicos,    son innumerables y diferentes unos de otros,  pues son   muchos los problemas que se pueden presentar sobre una   sola extremidad. Uno de los desarrollos m&aacute;s destacados   sobre las extremidades superiores,  trata el problema de   personas que han sufrido accidente cerebro-vascular.   Sukhan Le,  Arvin Agah y George Bekey,  en su trabajo   "<i>IROS: An inteligent rehabilitative orthotic system for   cerebrovascular accident</i>",  presentan un sistema para la   rehabilitaci&oacute;n de estos pacientes,  que busca re-ense&ntilde;ar   las funciones de la extremidad &#91;<a href="#17">17</a>&#93;. Esta &oacute;rtesis se   instrumenta con sensores de electromiograf&iacute;a (EMG),    tac&oacute;metros para medir la velocidad,  sensores de &aacute;ngulo,    sensores de fuerza y sensores de corriente en los motores   para medir el torque. Otro proyecto mucho m&aacute;s reciente   para el mismo fin,  lo muestranThomas G. Sugar,  Jiping He   y otros autores,  en el trabajo titulado "<i>Design and control   of RUPERT: a device for robotic upper extremity repetitive   therapy</i>" &#91;<a href="#18">18</a>&#93;,  en el a&ntilde;o 2007. &Eacute;ste integra un sistema de   instrumentaci&oacute;n muy completo,  pues sensa la posici&oacute;n con   aceler&oacute;metros de dos ejes,  la rotaci&oacute;n en las articulaciones   del codo,  el hombro y la cadera con potenci&oacute;metros   posicionados,  se estima la activaci&oacute;n voluntaria de los   m&uacute;sculos con se&ntilde;ales EMG y se usan sensores de fuerza   basados en presi&oacute;n. Toda esta informaci&oacute;n se env&iacute;a a un sistema de biofeedback para ser procesada.</p>     <p>Adem&aacute;s de la rehabilitaci&oacute;n,  otros exoesqueletos   tienen como finalidad brindar soporte o aumentar la fuerza   humana. Como ejemplo,  Kazuo Kiguchi,  Shingo Kariya,    Keigo Watanabe,  Kiyotaka Izumi y Toshio Fukuda,    en el art&iacute;culo "<i>An exoskeletal robot for human elbow   motion support-sensor fusion,  adaptation,  and control</i>"   &#91;<a href="#19">19</a>&#93;,  exponen el dise&ntilde;o un exoesqueleto para el brazo,    que brinda soporte y fuerza a la articulaci&oacute;n del codo,    bas&aacute;ndose en la informaci&oacute;n de los sensores de fuerza   ubicados en la mu&ntilde;eca y a las se&ntilde;ales EMG. Se usan   galgas extensiom&eacute;tricas como sensores de fuerza y un   motor DC (Harmonic Drive System Co.) como actuador   en la articulaci&oacute;n. Las se&ntilde;ales de EMG se obtienen con   electrodos ubicados de forma bicanal en el tr&iacute;ceps y el   b&iacute;ceps,  con el fin de detectar intencionalidad. Tambi&eacute;n,    con el prop&oacute;sito de ayudar a las personas a realizar   trabajos fuertes brindando un soporte adicional,  <i>Skil   Mate</i> &#91;<a href="#20">20</a>&#93; apunta a ayudar a los trabajadores calificados,    para apoyarlos en potencia y habilidad. El objetivo del   proyecto,  es desarrollar un prototipo rob&oacute;tico para un traje   espacial,  que consiste en un montaje de la parte superior   del torso y un par de brazos con guantes. Cada articulaci&oacute;n   es manejada por actuadores neum&aacute;ticos y puede sensar   &aacute;ngulos. Se compone de servo mecanismos,  dispositivos   h&aacute;pticos (sensores t&aacute;ctiles) para detectar el movimiento   humano y que la m&aacute;quina pueda seguir los movimientos   del astronauta,  y un sensor de torque-fuerza necesario   para lograr el control de impedancia en una cooperaci&oacute;n humano-m&aacute;quina.</p>     <p>Otro aporte importante relacionado con el uso de   los exoesqueletos en extremidades superiores,  es el   dise&ntilde;o presentado por Joel C. Perry y Jacob Rosen de la   Universidad de Washington,  "<i>Design of a 7 degree-offreedom   upper-limb powered exoskeleton</i>" &#91;<a href="#21">21</a>&#93;. Este   es un exoesqueleto antropom&eacute;trico con siete GDL,  que   se apoya en una base de datos que define la cinem&aacute;tica   y la din&aacute;mica de la extremidad superior en actividades   cotidianas. Usa motores y reducciones con poleas,    para el movimiento del sistema,  y sensores de posici&oacute;n   redundantes (potenci&oacute;metro-Midori,  Fullerton; Encoder-   HP),  uno en cada lado,  para monitorear tanto la movilidad articular como la posici&oacute;n del motor.</p>     <p>&nbsp;</p>     <p><b><font size="3">III. EXTREMIDADES INFERIORES</font></b> </p>     <p>Si se hace una b&uacute;squeda r&aacute;pida en libros o p&aacute;ginas web   acerca de los exoesqueletos en el mundo,  queda claro que   la gran mayor&iacute;a de estas estructuras es dise&ntilde;ada para las   extremidades inferiores,  pues son estas las m&aacute;s vulnerables   a lesiones y es ah&iacute; donde se concentra la mayor parte del   peso humano. A continuaci&oacute;n,  se hace referencia a algunos   de estos exoesqueletos para extremidades inferiores que   buscan solucionar muchos de los problemas causados por patolog&iacute;as o lesiones,  o que tambi&eacute;n buscan mejorar las capacidades f&iacute;sicas normales de un ser humano.</p>     ]]></body>
<body><![CDATA[<p><i><font size="3">3.1 Exoesqueletos para fuerza y habilidad:</font></i></p>     <p>Los exoesqueletos dise&ntilde;ados con objetivos   militares,  han aportado valiosa informaci&oacute;n acerca de la   instrumentaci&oacute;n y la construcci&oacute;n de los mismos. Dado   que estas estructuras buscan aumentar las capacidades y   habilidades del cuerpo humano,  su dise&ntilde;o y construcci&oacute;n   tiene muchas veces un alto grado de complejidad,  por lo   cual aportan un valioso conocimiento en el &aacute;rea; dicho   conocimiento se puede usar,  tambi&eacute;n,  en estructuras   con prop&oacute;sitos m&eacute;dicos. Uno de los desarrollos m&aacute;s   importantes,  al d&iacute;a de hoy,  es el que propuso el ingeniero   mec&aacute;nico Homayoon Kazerooni,  de la Universidad de   California: el "Berkeley Lower Extremity Exoskeleton   (BLEEX)". Este exoesqueleto,  tiene un enfoque militar   y se encarga de aumentar la fuerza del piloto al cargar   herramientas pesadas. En este sistema,  se sensan todas   las variables externas como la fuerza de reacci&oacute;n del   suelo,  por sensores de tipo on-off,  la velocidad angular,    la aceleraci&oacute;n angular y los &aacute;ngulos de las articulaciones   que son medidos con dos aceler&oacute;metros y encoders en los   motores. Esta informaci&oacute;n,  la describen Ryan Steger,  Sung   Hoon Kim y H. Kazerooni,  en el art&iacute;culo "<i>Control scheme   and networked control architecture for the Berkeley lower   extremity exoskeleton</i>",  y Andrew Chu,  Adam Zoss y H.   Kazerooni,  en el art&iacute;culo "On the biomimetic design of the   Berkeley lower extremity exoskeleton" &#91;<a href="#22">22</a>, <a href="#23">23</a>&#93;. En este   &uacute;ltimo art&iacute;culo &#91;<a href="#23">23</a>&#93;,  se describe el uso cl&iacute;nico de datos   para el an&aacute;lisis de marcha como el marco para el dise&ntilde;o   de un sistema de este tipo. Se muestra un an&aacute;lisis de la   marcha para cada articulaci&oacute;n involucrada,  incluyendo,    por supuesto,  la rodilla. Se observan curvas que   relacionan el tiempo con el &aacute;ngulo,  el torque y la potencia.   Conclusiones importantes como los &aacute;ngulos escogidos   para la rodilla,  el tobillo y la cadera,  en la estructura,  se   exponen en el documento. En "<i>On the mechanical design   of the berkeley lower extremity exoskeleton</i>",  se describe   la selecci&oacute;n de los grados de libertad y sus rangos de   movimiento para el exoesqueleto BLEEX &#91;<a href="#24">24</a>&#93;. Adem&aacute;s,    se cubren los aspectos significativos de dise&ntilde;o de los   componentes principales. Hay una descripci&oacute;n amplia   en cuanto al dise&ntilde;o mec&aacute;nico de la estructura,  basada   en estudios previos de la marcha humana. Se muestra   de forma clara cada articulaci&oacute;n dise&ntilde;ada en 3D,  dando   detalle de la forma de construcci&oacute;n,  los grados de libertad y el tipo de sensores que se usan en cada articulaci&oacute;n.</p>     <p>En otro de los art&iacute;culo relacionados con el BLEEX,    "<i>On the control of the Berkeley lower extremity   exoskeleton</i>" &#91;<a href="#25">25</a>&#93;,  se explican las cuatro nuevas   caracter&iacute;sticas con respecto a los exoesqueletos anteriores.   Primero,  una arquitectura moderna para controlar el   exoesqueleto que toma las medidas del exoesqueleto   mismo,  eliminando el problema de inestabilidad inducido   por el cuerpo humano. Segundo,  un sistema de potencia y   de energ&iacute;a lo suficientemente peque&ntilde;as; tercero,  una red   de &aacute;rea local (LAN) incorporada al cuerpo y un protocolo   espec&iacute;fico de comunicaci&oacute;n que elimina,  en gran parte,    el cableado,  y,  finalmente,  una arquitectura dise&ntilde;ada   cuidadosamente para que sea flexible y no consuma casi   energ&iacute;a. Dada la gran importancia del BLEEX y cada   una de sus etapas de desarrollo,  se presenta un an&aacute;lisis   del sistema en el art&iacute;culo "<i>Exoskeletons for human   power augmentation</i>" &#91;<a href="#26">26</a>&#93;. En &eacute;l,  se expone que el   objetivo principal del proyecto BLEEX es desarrollar las   tecnolog&iacute;as fundamentales asociadas al dise&ntilde;o y control   de exoesqueletos energ&eacute;ticamente aut&oacute;nomos para   extremidades inferiores,  que aumenten la fuerza humana   y la resistencia durante la locomoci&oacute;n. Se aclara que el   proyecto apunta hacia soldados,  rescatistas,  bomberos y   otro personal de emergencia,  para proveer la habilidad de   llevar cargas pesadas como comida,  equipos de rescate,  equipos de primeros auxilios,  y equipos de comunicaci&oacute;n.</p>     <p>Otro proyecto que propone un sistema para aumentar   la capacidad de la fuerza humana,  es el que presenta   Conor James Walsh en su tesis de Master of Science en   Ingenier&iacute;a Mec&aacute;nica,  "<i>Biomimetic design of an underactuated   leg exoskeleton for load-carrying augmentation</i>"   &#91;<a href="#27">27</a>&#93;,  y en su trabajo titulado "<i>Development of a light   weight,  underactuated exoskeleton for load-carrying   augmentation</i>" &#91;<a href="#28">28</a>&#93;. &Eacute;l realiza un dise&ntilde;o en el cual el   exoesqueleto trabaja en paralelo con los movimientos   del cuerpo,  para hacerlo m&aacute;s liviano y,  adem&aacute;s,  para que   soporte el peso de una carga adicional. Los componentes   del exoesqueleto,  en el plano sagital,  consisten de un   actuador en la cadera,  cuya fuerza es controlable,  un   mecanismo de amortiguamiento variable en la rodilla y   un mecanismo de resorte pasivo en el tobillo. Se habla   de la posibilidad de explotar de gran manera la din&aacute;mica   pasiva de la marcha,  pues la mayor&iacute;a de los desarrollos se   ha enfocado en exoesqueletos completamente actuados,    lo cual a&ntilde;ade mucho peso y demanda el uso de mucha energ&iacute;a.</p>     <p>Debido a la gran cantidad de energ&iacute;a que demanda   la puesta en marcha de este tipo de estructuras,  se han   realizado estudios acerca del tipo de fuentes de voltaje   que debe utilizarse para a&ntilde;adir la menor cantidad posible   de peso. El trabajo presentado por la Universidad de   California,  Berkeley,  "<i>Hybrid hydraulic-electric power   unit for field and service robots</i>",  muestra una fuente de   potencia que debe proporcionar energ&iacute;a constante en forma   de presi&oacute;n hidr&aacute;ulica y energ&iacute;a el&eacute;ctrica,  para alimentar   tanto a los actuadores como a los sensores y al sistema de procesamiento. Varias de estas unidades de potencia,    fueron probadas con &eacute;xito en el proyecto de exoesqueleto de la Universidad de Berkeley BLEEX &#91;<a href="#25">25</a>, <a href="#29">29</a>&#93;.</p>     <p>En el documento "<i>A leg exoskeleton utilizing   a magnetorheological actuator</i>",  se propone un   exoesqueleto para la pierna,  que usa actuadores magnetoreol&oacute;gicos   (MR) para proveer torque asistido controlable   que permita el uso eficiente de energ&iacute;a &#91;<a href="#30">30</a>&#93;. Los estados   de la articulaci&oacute;n de la rodilla,  se determinan por medio   de la medici&oacute;n del &aacute;ngulo de la rodilla y la fuerza de   reacci&oacute;n de &eacute;sta con el suelo. Las partes principales del   sistema incluyen: abrazaderas,  actuador con fluido MR y   sensores. Dos sensores de fuerza se montan en las partes   delantera y trasera de la suela del pie,  para medir la fuerza   de reacci&oacute;n del suelo; dos medidores de tensi&oacute;n (<i>strain   gauges</i>) est&aacute;n instalados en las partes delantera y trasera   de la abrazadera inferior,  para medir la fuerza que act&uacute;a   sobre el actuador,  y se usa un potenci&oacute;metro para medir   &aacute;ngulos en la rodilla. El conjunto de sensores sirve para   determinar la posici&oacute;n de la articulaci&oacute;n de la rodilla,    la cual es utilizada por el controlador para avanzar al   siguiente estado. Dependiendo de estos estados,  cuando se   requiere un torque pasivo ajustable,  el sistema MR act&uacute;a   como un freno,  consumiendo muy poca energ&iacute;a,  y,  cuando   se requiere un toque activo,  el sistema trabaja como un   embrague,  que transfiere el torque generado por el motor a la pierna del usuario.</p>     <p>Muy pocos desarrollos se enfocan en la optimizaci&oacute;n   del correr humano,  puesto que correr no es una condici&oacute;n   cotidiana. Sin embargo,  en el art&iacute;culo presentado por   Aaron M. Dollar y Hugh Herr,  "<i>Design of a quasi-passive   knee exoskeleton to assist running</i>" &#91;<a href="#31">31</a>&#93;,  se describen   el dise&ntilde;o y las primeras pruebas de un exoesqueleto   de rodilla energ&eacute;ticamente aut&oacute;nomo para facilitar la   corrida. Consiste de un mecanismo motorizado,  que est&aacute;   sujeto a la pierna por medio de moldes y abrazaderas.   Este mecanismo motorizado,  agrega o quita un muelle   (elemento el&aacute;stico) mientras el paciente corre. Cuando   el tal&oacute;n entra en contacto con el suelo,  el muelle est&aacute; en   paralelo a la rodilla y almacena energ&iacute;a,  que ser&aacute; liberada   una vez la persona entre en la fase de balanceo mientras   est&aacute; corriendo; todo esto,  con el fin de reducir el costo metab&oacute;lico asociado a una persona que est&aacute; corriendo.</p>     <p><i><font size="3">3.2 Exoesqueletos para rehabilitaci&oacute;n:</font></i></p>     <p>Las extremidades inferiores,  nos permiten el   desplazamiento y son la base de la independencia de una   persona; por eso la gran importancia de los desarrollos   que basan sus esfuerzos en la asistencia y la rehabilitaci&oacute;n   de las personas que han sufrido alg&uacute;n accidente o que   presentan alguna patolog&iacute;a que afecte su movimiento.   Como un ejemplo importante en esta &aacute;rea,  est&aacute; el llamado   <i>AKROD</i>,  el cual es un dispositivo ortop&eacute;dico para   rehabilitaci&oacute;n activa de rodilla,  dise&ntilde;ado para entrenar   a pacientes con accidente cerebro-vascular,  que sufren   de h&iacute;per-extensi&oacute;n de la rodilla en la fase de apoyo de   la marcha y de flexi&oacute;n reducida de la rodilla durante la   fase de balanceo &#91;<a href="#32">32</a>&#93;. Adem&aacute;s,  existen exoesqueletos   orientados hacia la recuperaci&oacute;n post operaci&oacute;n. Este es   el caso del sistema de rehabilitaci&oacute;n presentado por Jan   Brutovsk&yacute; y Daniel Nov&aacute;k &#91;<a href="#33">33</a>&#93;,  quienes hablan de las   fracturas en las articulaciones como uno de los mayores   problemas de salud en los pa&iacute;ses desarrollados. El sistema   de rehabilitaci&oacute;n dise&ntilde;ado,  le permite a los m&eacute;dicos hacer   prescripci&oacute;n,  demostraci&oacute;n y monitoreo de los protocolos   de rehabilitaci&oacute;n,  durante y entre las visitas programadas.   Se enfocan en la rehabilitaci&oacute;n desde la casa del paciente,    de bajo costo y alta aceptaci&oacute;n por parte de los usuarios,    pues adem&aacute;s se motiva al paciente por medio de t&eacute;cnicas de <i>biofeedback</i>.</p>     <p>Ekta Singla,  Bhaskar Dasgupta y otros autores,  en   el art&iacute;culo "<i>Optimal design of an exoskeleton hip using   three-degrees-of-freedom spherical mechanism</i>" &#91;<a href="#34">34</a>&#93;,    presentan el dise&ntilde;o de una articulaci&oacute;n de cadera para   asistir en los movimientos a personas f&iacute;sicamente d&eacute;biles.   El mecanismo es una articulaci&oacute;n con tres grados de   libertad (GDL),  y se enfoca en determinar la correcta   alineaci&oacute;n de los puntos de la estructura con el cuerpo   humano,  teniendo en cuenta la anatom&iacute;a del cuerpo y   el confort de la persona que use dicho mecanismo. En   Argentina,  se dise&ntilde;&oacute; una &oacute;rtesis rob&oacute;tica,  cuyo objetivo   es optimizar tanto la recuperaci&oacute;n del paciente como   la pr&aacute;ctica profesional del terapeuta &#91;<a href="#35">35</a>&#93;. Esta &oacute;rtesis   cuenta con seis GDL y tiene actuadores sobre la cadera,  la   rodilla,  el tobillo y el pie. En el dise&ntilde;o,  s&oacute;lo se consideran   las componentes en el plano sagital de las variables   biomec&aacute;nicas. La propuesta incluye una estructura   graduable en altura y de bajo peso,  con fibra de carbono,    servomotores y reductores. En cuanto a los actuadores,    los autores proponen el uso de servomotores alemanes   con reductores <i>Harmonic Drive</i> para cada articulaci&oacute;n,    dejando abierta la posibilidad de usar elementos de la   industria nacional Argentina. Para el sistema de control,    proponen un sistema de control de posici&oacute;n y el dise&ntilde;o se eval&uacute;a por medio de simulaciones.</p>     ]]></body>
<body><![CDATA[<p>Otro desarrollo de mucha importancia en la   rehabilitaci&oacute;n de pacientes,  es el presentado por J.L.   Pons,  J.C. Moreno,  F.J. Brunetti y E. Rocon,  "<i>Lowerlimb   wearable exoskeleton</i>" &#91;<a href="#36">36</a>&#93;. Este es un sistema de   compensaci&oacute;n y evaluaci&oacute;n de la marcha patol&oacute;gica,  para   aplicaciones,  en condiciones reales,  como una metodolog&iacute;a   de asistencia y evaluaci&oacute;n de los problemas que afectan la   movilidad de individuos con des&oacute;rdenes neuro-motores.   La implementaci&oacute;n de sensores para el control,  consiste de una unidad de medici&oacute;n inercial (IMU) en el pie (debajo   de la articulaci&oacute;n del tobillo en la &oacute;rtesis),  y una segunda   unidad en la barra inferior del exoesqueleto. Cada IMU   se compone de un &uacute;nico gir&oacute;scopo MEMs (Analogue   Device ADXRS300),  con una sensibilidad m&aacute;xima de   +/- 300/s,  y de un aceler&oacute;metro de doble eje de 200 mV/g   (ADXL202). Se usa un sensor de posici&oacute;n angular de   precisi&oacute;n,  con un rango de &aacute;ngulo el&eacute;ctrico efectivo de   340 grados,  para un seguimiento continuo del &aacute;ngulo de   la articulaci&oacute;n de la rodilla en el plano sagital. Un sensor   de presi&oacute;n resistivo (5 mm en di&aacute;metro de &aacute;rea efectiva;   0, 30 mm de grosor),  se usa para monitorear el estado del   mecanismo de enganche de la rodilla. Las se&ntilde;ales de las   IMU,  se digitalizan usando un convertidor A/D de 10 bits,    Atmega128 Atmel Inc.,  muestreando a 100 Hz,  con una   referencia de voltaje de 3, 3V y una resoluci&oacute;n de 2, 92 mV/   bit. El sistema de monitoreo y control incluy&oacute; dos botones   para un control directo por medio del usuario,  ofreciendo   la posibilidad de habilitar o deshabilitar totalmente la estrategia de control en cualquier momento.</p>     <p>Tambi&eacute;n de gran relevancia,  por su funcionalidad,    est&aacute; el sistema llamado LOPES &#91;<a href="#37">37</a>&#93;. &Eacute;ste combina   un segmento accionado transportable 2D,  con un   exoesqueleto para las piernas que contiene tres   articulaciones actuadas: dos en la cadera y una en la   rodilla. Las juntas son de impedancia controlada,  para   permitir una interacci&oacute;n mec&aacute;nica entre el sujeto y el   robot. El dispositivo permite dos modos de operaci&oacute;n: que   el "paciente est&eacute; a cargo" y que "el robot est&eacute; a cargo".   El robot puede seguir las &oacute;rdenes del paciente o guiar al   paciente,  respectivamente. El dispositivo debe permitir   que una persona sana use el modo "paciente a cargo",    sin sentir restricciones para su marcha normal. Un tercer   modo,  "terapista a cargo",  se incluye,  donde cualquier   intervenci&oacute;n del terapista pueda ser programada. Otros   autores enfocan sus esfuerzos no s&oacute;lo en la parte funcional   de la estructura,  sino tambi&eacute;n en la parte del consumo   energ&eacute;tico de la persona que la usa,  buscando siempre   realizar movimientos m&aacute;s eficientes. Andrew Valiente,  en   su tesis para Master of Science,  "<i>Design of a quasi-passive   parallel leg exoskeleton to augment load carrying for   walking</i>",  presenta el dise&ntilde;o de un exoesqueleto para la   pierna,  que ayuda a reducir el costo metab&oacute;lico durante la   marcha mientras se transporta una carga de 75 libras &#91;<a href="#38">38</a>&#93;.   El exoesqueleto trabaja de forma paralela a las piernas,    transfiriendo las fuerzas de la carga &uacute;til hacia el suelo. Para   contribuir con la eficiencia de la marcha,  implementan   sistemas pasivos de resortes en la cadera y el tobillo,  con   el fin de almacenar y liberar energ&iacute;a durante el ciclo de   marcha. Para comprobar la hip&oacute;tesis de que se reduce el   costo metab&oacute;lico en la marcha,  se mide el consumo de   ox&iacute;geno del paciente a una velocidad seleccionada por el mismo.</p>     <p>Son muchas y muy variadas,  las investigaciones   relacionadas con exoesqueletos para extremidades   inferiores. Sin embargo,  muchos han hecho &eacute;nfasis en   la rodilla,  pues es una de las articulaciones que m&aacute;s   sufre en el momento de caminar y m&aacute;s en el momento   de correr. Buscando aportar alguna soluci&oacute;n para la   rehabilitaci&oacute;n de rodilla,  el Ingeniero Esteban Emilio   Rosero,  en su trabajo de grado,  presenta el proyecto   "<i>Dise&ntilde;o y construcci&oacute;n de una m&aacute;quina de movimiento   pasivo continuo para la terapia de rodilla</i>" &#91;<a href="#39">39</a>&#93;,  en el   cual se expone el dise&ntilde;o sistem&aacute;tico de un prototipo para   la terapia de rodilla. El trabajo muestra la integraci&oacute;n de   diferentes &aacute;reas de la ingenier&iacute;a,  incluyendo la autom&aacute;tica,    la mec&aacute;nica,  la electr&oacute;nica y la medicina. Los conceptos   alrededor de estas &aacute;reas,  son utilizados para tener un mejor   entendimiento de las herramientas que usa el m&eacute;dico en   las terapias. El prototipo se construy&oacute; usando Dibujo   Asistido por Computadora (CAD,  por sus siglas en ingl&eacute;s),    y la Ingenier&iacute;a Asistida por Computadora (CAE,  por sus   siglas en ingl&eacute;s) se us&oacute; para la simulaci&oacute;n din&aacute;mica,  con lo   cual obtuvieron un prototipo virtual. Lograron un modelo   anal&iacute;tico y compararon con los resultados de la simulaci&oacute;n   din&aacute;mica para validar los modelos computacionales.   Finalmente,  despu&eacute;s de la simulaci&oacute;n y la validaci&oacute;n del   sistema,  procedieron al dise&ntilde;o y construcci&oacute;n del prototipo   con su sistema de potencia y de control. El prototipo   consiste,  b&aacute;sicamente,  en un soporte para el pie,  la pierna   y el muslo; un tornillo de potencia,  un eje de apoyo del   tornillo de potencia,  pasadores,  un motor de corriente continua y plantillas de felpa.</p>     <p>Debido a la alta complejidad del cuerpo humano,  gran   cantidad de investigadores se ha tomado el trabajo de   probar,  dise&ntilde;ar y proponer distintas formas para controlar   este tipo de estructuras. En el art&iacute;culo "<i>Analysis and   simulation of an exoskeleton controller that accommodates   static and reactive loads</i>" &#91;<a href="#40">40</a>&#93;,  se provee un m&eacute;todo para   resolver el problema de control por medio de la relegaci&oacute;n   del control humano y el control del exoesqueleto a dos   sub-sistemas de control. El primer sub-sistema,  representa   la ejecuci&oacute;n de control voluntario. El segundo subsistema,    representa al controlador del exoesqueleto,  responsable   del nivel de las juntas y fuerzas gravitacionales,  est&aacute;ticas   y reactivas. El control del sistema acoplado hombreexoesqueleto   se relega al control de generaci&oacute;n de   movimientos y al control de fuerza est&aacute;tica/reactiva. Los   componentes est&aacute;ticos,  los cuales balancean la gravedad y   las cargas est&aacute;ticas,  representan el componente dominante   del compensador,  por lo cual el principal objetivo del   exoesqueleto es conservar el equilibrio por medio de   la compensaci&oacute;n del cambio de energ&iacute;a potencial. La   divisi&oacute;n del control humano y del exoesqueleto en energ&iacute;a   cin&eacute;tica y potencial,  respectivamente,  mitiga la cantidad   de interferencia entre el control voluntario y el control de asistencia. En otro de los trabajos importantes con   respecto al control de estos sistemas,  A. Selk Ghafari,  A.   Meghdari y G. R. Vossoughi,  en el trabajo "<i>Intelligent   Control of Powered Exoskeletonto Assist Paraplegic   Patients Mobility using Hybrid Neuro-Fuzzy ANFIS   Approach</i>" &#91;<a href="#41">41</a>&#93;,  presentan un estudio que trata de emplear   la adaptaci&oacute;n neuro-difusa y el sistema de inferencia   (ANFIS) en control de exoesqueletos inteligentes,  para   ayudar a la movilidad de los pacientes parapl&eacute;jicos. Dado   que la estrategia de control propuesta,  no se vio afectada   por cambios en la din&aacute;mica humana,  se incrementaron la   fiabilidad y la robustez del controlador para la seguridad   en la interacci&oacute;n con los seres humanos. El modelo   propuesto,  es independiente de cambios en la din&aacute;mica   humana,  y no se necesita usar el exoesqueleto para realizar din&aacute;mica inversa en el dise&ntilde;o del controlador.</p>     <p>Aunque poco comunes,  existen estructuras tipo   exoesqueleto que son no actuadas,  es decir que no existe   ning&uacute;n motor o actuador que genere movimiento. Un caso   particular,  es el exoesqueleto pasivo presentado por Sunil   K. Agrawal (PhD),  Sai K. Banala y Abbas Fattah (PhD),    "<i>A Gravity Balancing Passive Exoskeleton for the Human   Leg</i>" &#91;<a href="#42">42</a>&#93;,  el cual se basa en el principio de equilibrar la   gravedad; consiste en localizar el centro de masa del   sistema combinado (humano + exoesqueleto) y a&ntilde;adir   muelles al exoesqueleto,  uno entre el centro de masa del   sistema combinado y el centro de masa de marco fijo que   representa al tronco,  y los dem&aacute;s dentro de los enlaces del   exoesqueleto,  para que la energ&iacute;a potencial del sistema   combinado sea invariante con la configuraci&oacute;n de la   pierna. En el documento describen la teor&iacute;a del equilibrio   de la gravedad,  se realizan pruebas EMG para probar el   desempe&ntilde;o del exoesqueleto y se proponen aplicaciones potenciales del exoesqueleto,  como la rehabilitaci&oacute;n.</p>     <p>&nbsp;</p>     <p><b><font size="3">IV. EXOESQUELETOS Y  ELECTROMIOGRAF&Iacute;A</font></b></p>     <p>La gran mayor&iacute;a de los exoesqueletos construidos,    no toma en cuenta las se&ntilde;ales electromiogr&aacute;ficas como   parte de su sistema de control,  bien sea porque no son   necesarias o por la gran complejidad que implica el uso de   las mismas. Sin embargo,  algunos usan las se&ntilde;ales EMG   como parte fundamental de su sistema,  y los diferentes   estudios alrededor de este tema podr&iacute;an ser &uacute;tiles para futuros desarrollos.</p>     <p>Una parte muy importante del uso de se&ntilde;ales   electromiogr&aacute;ficas en exoesqueletos,  es poder realizar una   clasificaci&oacute;n y caracterizaci&oacute;n de las mismas. El trabajo de   pregrado presentado por el ingeniero John Jairo Villarejo   &#91;<a href="#43">43</a>&#93;,  muestra el desarrollo de un sistema software para   procesar y realizar la caracterizaci&oacute;n y la clasificaci&oacute;n de   se&ntilde;ales electromiogr&aacute;ficas,  con el prop&oacute;sito de determinar   las funciones que debe realizar una pr&oacute;tesis transfemoral   por medio de la detecci&oacute;n de intenci&oacute;n,  resultado del   an&aacute;lisis de estas se&ntilde;ales. Por su parte,  el ingeniero &Aacute;lvaro   Ernesto R&iacute;os,  en su tesis de pregrado &#91;<a href="#44">44</a>&#93;,  presenta un   trabajo en el cual se pretende,  mediante el desarrollo de   un sistema microcontrolado para el control de pr&oacute;tesis   mioel&eacute;ctricas con realimentaci&oacute;n sensorial,  solucionar   parte del problema de sensaci&oacute;n de miembro perdido a personas que hayan sufrido de amputaci&oacute;n.</p>     <p>La detecci&oacute;n de intenci&oacute;n,  es otra alternativa para   exoesqueletos de rehabilitaci&oacute;n motora. Los autores   M. Bureau,  G. Eizmendi,  E. Olaiz,  H. Zabaleta,  J.   Medina y M. P&eacute;rez,  en su art&iacute;culo "<i>Dise&ntilde;o de un nuevo   exoesqueleto para neurorehabilitaci&oacute;n basado en   detecci&oacute;n de intenci&oacute;n</i>" &#91;<a href="#45">45</a>&#93;,  presentan el primer a&ntilde;o   de trabajo en un exoesqueleto donde la detecci&oacute;n de   intenci&oacute;n se basa en la monitorizaci&oacute;n de los &aacute;ngulos de   cadera y rodilla. Tambi&eacute;n,  muestran la posibilidad de   incorporar un sistema de monitorizaci&oacute;n de EMG para la   detecci&oacute;n de intenci&oacute;n,  control y <i>neurofeedback</i>. Otro de   los trabajos que utiliza la intencionalidad por medio de   electromiograf&iacute;a,  es el de los Japoneses Kazuo Kiguchi'l,    Takakazu Tanakal,  Keigo Watanabe y Toshio Fukuda,  en   su art&iacute;culo "<i>Design and control of an exoskeleton system   for human upper-limb motion assist</i>" &#91;<a href="#46">46</a>&#93;,  en el cual se   presenta un exoesqueleto para asistir en el movimiento de   las extremidades superiores. Cuenta con tres GDL y utiliza   las se&ntilde;ales electromiogr&aacute;ficas de superficie,  como parte   fundamental del sistema,  para entender c&oacute;mo el paciente   desea moverse. A partir de estas se&ntilde;ales,  el exoesqueleto   asiste autom&aacute;ticamente al paciente en sus movimientos de   rehabilitaci&oacute;n diaria,  utilizando control neuro-difuso,  para   lograr un buen sistema de control,  debido a la complejidad   de la utilizaci&oacute;n de las se&ntilde;ales de los m&uacute;sculos como entradas a un sistema de control en tiempo real.</p>     ]]></body>
<body><![CDATA[<p>Quiz&aacute;s uno de los trabajos m&aacute;s completos e   importantes alrededor de los exoesqueletos y la   electromiograf&iacute;a,  es el que exponen Christian Fleischer   y G&uuml;nter Hommel,  de la Universidad de Tecnolog&iacute;a de   Berl&iacute;n,  en el art&iacute;culo "<i>Torque control of an exoskeletal   knee with EMG signals</i>" &#91;<a href="#47">47</a>&#93;,  en el cual se presentan   un esquema y un algoritmo de control para una &oacute;rtesis   mec&aacute;nica de rodilla,  que se basa en el reconocimiento de   intenci&oacute;n obtenido a trav&eacute;s de la evaluaci&oacute;n en tiempo   real de las se&ntilde;ales EMG de los m&uacute;sculos de la pierna. Un   controlador de torque,  en un actuador lineal,  se encarga   de ejecutar los movimientos deseados,  y se realiza sin   la necesidad de hacer reconocimiento de patrones ni un   modelo biomec&aacute;nico del cuerpo humano. El exoesqueleto,    consiste de una &oacute;rtesis que cubre la pierna,  un actuador,    un sistema sensor,  un microcontrolador con el software de   control,  un sistema de seguridad hardware y un PC para   la visualizaci&oacute;n de los datos y la interacci&oacute;n. El actuador realiza flexi&oacute;n y extensi&oacute;n de la rodilla y rodilla,  y brinda   apoyo al paciente por medio de un torque adicional en dicha articulaci&oacute;n.</p>     <p>Utilizando se&ntilde;ales de los m&uacute;sculos alrededor del   codo,  Jacob Rosen y otros autores,  en el art&iacute;culo "<i>A   myosignal-based powered exoskeleton system</i>" &#91;<a href="#48">48</a>&#93;,    pretenden mostrar la interacci&oacute;n de un exoesqueleto   con el brazo humano. Se usan las se&ntilde;ales EMG,  para   predecir el movimiento del m&uacute;sculo en el codo y un   actuador estar&iacute;a ubicado en la parte de la articulaci&oacute;n   del codo. B&aacute;sicamente,  este exoesqueleto amplifica la   fuerza de los m&uacute;sculos relativos al codo,  cuando se est&aacute;   realizando alg&uacute;n trabajo o manipulando una carga. Usa un   servo motor DC de 360 NM,  en la articulaci&oacute;n del codo,    equipado con una caja de engranajes y un encoder. Entre el   exoesqueleto y la parte donde se est&aacute; ubicando la carga,  y   entre el exoesqueleto y la mano,  se montaron sensores de   fuerzas TEDEA 1040. En el primer caso,  el sensor mide   la fuerza de reacci&oacute;n total con respecto al peso que se est&aacute;   cargando,  y,  en el segundo,  mide la fuerza que se aplica   al piloto del exoesqueleto. Para el sistema mioel&eacute;ctrico,    utilizan electrodos de 8 mm BIOPAC EL208S,  que se   colocan en la piel; la se&ntilde;al,  se obtiene por el amplificador   de EMG BIOPAC EMG100A,  usando una ganancia entre   2000 y 5000. La se&ntilde;al se digitaliza a una rata de muestreo   de 1 kHz y,  por medio de un PC,  se dise&ntilde;a la interfaz en   tiempo real,  implementando el bloque de tiempo real de MATLAB.</p>     <p>El sistema HAL 5,  tal vez uno de los desarrollos   comerciales m&aacute;s importantes en el momento,  es expuesto   por el profesor Yoshiyuki Sankai de la Universidad de   Tsukuba &#91;<a href="#49">49</a>&#93;. Este sistema,  ejecuta un comportamiento de   marcha,  bas&aacute;ndose en las se&ntilde;ales biol&oacute;gicas EMG,  para   identificar la intencionalidad de la persona y poder realizar   el movimiento deseado. Utiliza motores DC Harmonic   Drive,  para asistir con el torque requerido. La informaci&oacute;n   relacionada a la construcci&oacute;n de esta estructur, a se   encuentra en el art&iacute;culo "<i>Power assist method for HAL-3 using EMG-based feedback controller</i>",  realizado   por Yoshiyuki Sankai junto con Hiroaki Kawainot, o.,    Siiwoong Lee y Shigehiro Kanbe. Este art&iacute;culo,  describe   el sistema de sensado de las se&ntilde;ales electromiogr&aacute;ficas en   los trabajos previos al HAL-5(HAL-3),  los sistemas de   instrumentaci&oacute;n usados para medir otras variables y las partes que componen la plataforma de control.</p>     <p>Finalmente,  "<i>Embedded control system for a powered   leg exoskeleton</i>" &#91;<a href="#50">50</a>&#93; es de los trabajos m&aacute;s completos   con respecto al control necesario en estos sistemas que   usan se&ntilde;ales mioel&eacute;ctricas. &Eacute;ste,  presenta un control   embebido para una &oacute;rtesis,  que es usada para brindar   soporte a los m&uacute;sculos durante la flexi&oacute;n y extensi&oacute;n de   la rodilla. El control es implementado usando se&ntilde;ales   EMG para detectar la intencionalidad de movimiento   de la persona,  buscando encontrar la activaci&oacute;n del   m&uacute;sculo y las enfermedades que pueda tener el mismo.   Mencionan que el movimiento de la rodilla se puede   estimar con trece m&uacute;sculos que la rodean,  pudiendo   con esto determinar el torque que puede ser usado para   el control. El sistema de control est&aacute; divido en cuatro   partes: sensores y actuadores,  el microcontrolador con   el software de control,  el PC para visualizar los datos y   el hardware de seguridad. Los sensores utilizados son el   sensor de efecto hall KMZ41 de Philips,  los seis sensores   EMG de marca Delsys (electrodos diferenciales),  y los   sensores de fuerza GS Sensor XFTC 3008 en serie con el   actuador lineal. El actuador consiste en un motor de DC   Maxon RE35 de 90W y lo maneja un amplificador PWM   Copley 4122Z. Toda la informaci&oacute;n de los sensores,  se   digitaliza y env&iacute;aal microcontrolador por medio de una   red SPI. Todos estos sensores y actuadores,  usan circuitos   convertidores MAX1230ADC,  AD5530 DAC,  UZZ9001,    para comunicarse con el microcontrolador Atmel Mega   32 por medio de un bus SPI. El microcontrolador es el   responsable de tomar las se&ntilde;ales de los sensores,  procesar   el movimiento deseado y enviar la se&ntilde;al PWM apropiada.   La comunicaci&oacute;n con el PC es v&iacute;a USB y no es en tiempo   real. Las se&ntilde;ales EMG se toman de varios m&uacute;sculos,  pero   las que se usan para el control son las se&ntilde;ales del recto femoral,  vasto medial y el semimembranoso.</p>     <p>&nbsp;</p>     <p><b><font size="3">V. CONCLUSI&Oacute;N</font></b> </p>     <p>A partir de este art&iacute;culo,  se genera un documento   que aporta unas bases te&oacute;ricas de gran importancia   en el momento que se desee realizar alg&uacute;n dise&ntilde;o o   construcci&oacute;n de un sistema tipo exoesqueleto,  facilitando   al investigador proponer una mejor y m&aacute;s estructurada   soluci&oacute;n. Esta revisi&oacute;n,  permite conocer y aprender varias   t&eacute;cnicas aplicadas para la construcci&oacute;n y dise&ntilde;o de estos   ejemplares,  tambi&eacute;n las aplicaciones para las cuales   los exoesqueletos pueden ser usados y,  sobre todo,  la   importancia de optar por sistemas electr&oacute;nicos para su uso en la industria y la salud.</p>     <p>Debido a que el desarrollo de exoesqueletos involucra   muchas ramas de la ingenier&iacute;a electr&oacute;nica,  como los   sistemas de comunicaci&oacute;n,  la instrumentaci&oacute;n electr&oacute;nica   (sensores y actuadores),  el control (an&aacute;logo y digital) y la   potencia,  este tipo de proyectos se convierten en sistemas   completos de conocimiento,  enriquecidos en teor&iacute;as y   t&eacute;cnicas con un marco muy grande de la investigaci&oacute;n,    adem&aacute;s de que se involucran grupos interdisciplinarios   que aportan otros conocimientos,  como las &aacute;reas de la mec&aacute;nica y la salud.</p>     <p>Como se puede ver en este art&iacute;culo,  y en diferentes   situaciones de la vida diaria,  los seres humanos somos muy propensos a sufrir lesiones en nuestras extremidades,    debido a que &eacute;stas est&aacute;n siempre expuestas y en constante   contacto con distintas superficies y esfuerzos. Es por esto   que,  por medio de los exoesqueletos,  se busca optimizar   la rehabilitaci&oacute;n de pacientes y ofrecer,  en un futuro,    protecci&oacute;n y soporte a las partes que componen el cuerpo humano.</p>     <p>Se puede deducir,  f&aacute;cilmente,  que la electromiograf&iacute;a   no se usa mucho en los sistemas de control para   exoesqueletos. Sin embargo,  como se puede ver en esta   revisi&oacute;n,  varios estudios han tratado el tema dirigiendo   sus intereses a la detecci&oacute;n de intenci&oacute;n,  lo cual,  en un   futuro no muy lejano,  podr&iacute;a ser de gran importancia para   el dise&ntilde;o de sistemas de control que tengan en cuenta lo   que la persona desea hacer sin la necesidad de elementos   externos,  como botones o pulsadores,  que quiz&aacute; est&eacute;n fuera del alcance del paciente y,  por lo tanto,  resten autonom&iacute;a.</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><b><font size="3">VI. REFERENCIAS</font></b> </p>     <!-- ref --><p>&#91;<a name="1">1</a>&#93; Wang J.,  Li J.,  Zhang Y.,  Wang S. Design of an exoskeleton   for index finger rehabilitation. <i>Proceedings of the 31st Annual   International Conference of the IEEE-EMBS</i>,  Minneapolis,  USA,    September 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000075&pid=S1909-9762201000010000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="2">2</a>&#93; Wege A.,  Kondak K.,  Hommel G. Mechanical design and motion   control of a hand exoskeleton for rehabilitation. <i>Proceedings   of the International IEEE Conference on Mechatronics and   Automation (ICMA)</i>,  Ontario,  Canada,  July-August 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000077&pid=S1909-9762201000010000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="3">3</a>&#93; Shields B. L.,  Main J.A.,  Peterson S.W.,  Strauss A.M. An   anthropomorphic hand exoskeleton to prevent astronaut hand   fatigue during extravehicular activities. <i>IEEE Transactions on   Systems,  Man and Cybernetics,  Part A: Systems And Humans</i>,  27   (5),  668-673,  1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000079&pid=S1909-9762201000010000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="4">4</a>&#93; Koyama T.,  Yamano I.,  Takemura K., Maeno T. Multi-fingered   exoskeleton haptic device using passive force feedback for   dexterous teleoperation. <i>Intl. Conference of Intelligent Robots and   Systems</i>,  Lausanne,  Switzerland,  October 2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000081&pid=S1909-9762201000010000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="5">5</a>&#93; Stergiopoulos P.,  Fuchs P.,  Laurgeau C. Design of a 2-finger hand   exoskeleton for VR grasping simulation. <i>EuroHaptics</i>, Dublin,    Ireland,  July 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S1909-9762201000010000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="6">6</a>&#93; Bouzit M.,  Burdea G.,  Popescu G.,  Boian R. The rutgers master   II-new design force-feedback glove. <i>IEEE/Asme Transactions on   Mechatronics</i>,  7(2),  256-263,  2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S1909-9762201000010000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="7">7</a>&#93; Choi B.H.,  Choi H.R. A semi-direct drive hand exoskeleton using   ultrasonic motor. <i>Proceedings Of the 1999 IEEE International   Workshop on Robot And Human Interaction</i>,  Pisa,  Italia,    September 1999.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S1909-9762201000010000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="8">8</a>&#93; Amat J.,  Frigola M.,  Casals A. Experimental Robotics VII.   Springer-Verlag,  2000. Virtual exoskeleton for telemanipulation,    21-30.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S1909-9762201000010000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="9">9</a>&#93; G&oacute;mez M.,  Anzola J.N.,  Barrero D. Sistemas de Captura de   Movimiento-EXOC AP. <i>Loop de Animaci&oacute;n</i>,  Bogot&aacute;,  Colombia,    octubre 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S1909-9762201000010000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="10">10</a>&#93; Molina J.E.,  Gonz&aacute;lez J.P. Desarrollo de un sistema de control de   un exoesqueleto para asistencia del movimiento del codo. <i>Scientia   et Technica A&ntilde;o XIV</i>,  39,  129-134,  septiembre 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S1909-9762201000010000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="11">11</a>&#93; Molina J.E.,  Orozco A.A. Desarrollo de un sistema de control   para asistencia del movimiento humano tipo flexi&oacute;n-extensi&oacute;n   del brazo,  para el desarrollo de exoesqueletos. <i>Proyecto de   investigaci&oacute;n</i>. Universidad Tecnol&oacute;gica de Pereira,  2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S1909-9762201000010000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="12">12</a>&#93; Chou W., Wang T.,  Xiao J. Haptic interaction with virtual   environment using an arm type exoskeleton device. <i>IEEE   International Conference on Robotics and Automation</i>,  New   Orleans,  April 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S1909-9762201000010000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="13">13</a>&#93; Mistry M.,  Mohajerian P.,  Schaal S. Arm movement experiments   with joint space force fields using an exoskeleton robot. <i>IEEE 9th   International Conference on Rehabilitation Robotics</i>,  Chicago,    Illinois,  June 28-July 1 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S1909-9762201000010000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="14">14</a>&#93; Tsagarakis N.G.,  Caldwell D.G. A compliant exoskeleton for   multi-planar upper limb physiotherapy and training. Advanced   Robotics,  2007. Art&iacute;culo invitado.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S1909-9762201000010000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="15">15</a>&#93; Guti&eacute;rrez R.,  Ni&ntilde;o-Suarez P.A.,  Aviles-S&aacute;nchez O. F.,  Vanegas F.,    Duque J. Exoesqueleto mecatr&oacute;nico para rehabilitaci&oacute;n motora.   <i>Octavo Congreso Iberoamericano de Ingenieria Mecanica</i>,    Cusco,  Per&uacute;,  octubre 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S1909-9762201000010000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="16">16</a>&#93; Papadopoulos E.,  Patsianis G. Design of an exoskeleton   mechanism for the shoulder joint. <i>12th IFToMM World Congress</i>,    Besan&ccedil;on,  France,  June 18-21 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S1909-9762201000010000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="17">17</a>&#93; Lee S.,  Agah A.,  Bekey G. IROS: An Intelligent Rehabilitative   Orthotic System for cerebrovascular accident. <i>IEEE International   Conference on Systems,  Man and Cybernetics Conference   Proceedings</i>,  4-7,  815-819,  November 1990.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S1909-9762201000010000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="18">18</a>&#93; Sugar T.G.,  He J.,  Koeneman E.J.,  Koeneman J.B.,  Herman   R.,  Huang H.,  Schultz R.S.,  Herring D.E.,  Wanberg J.,    Balasubramanian S.,  Swenson P.,  Ward J.A. Design and   Control of RUPERT: A device for Robotic Upper Extremity   Repetitive Therapy. <i>IEEE Transactions on Neural Systems And   Rehabilitation Engineering</i>,  15(3),  336-46,  September 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S1909-9762201000010000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="19">19</a>&#93; Kiguchi K.,  Kariya S.,  Watanabe K.,  Izumi K.,  Fukuda T. An   exoskeletal robot for human elbow motion support-sensor fusion,    adaptation,  and control. <i>IEEE Transactions On Systems,  Man,    And Cybernetics-Part B: Cybernetics</i>,  31(3),  353-61,  June 2001.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S1909-9762201000010000800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="20">20</a>&#93; Umetani Y.,  Yamada Y.,  Morizono T.,  Yoshida T.,  Aoki S. "Skil   Mate",  Wearable Exoskeleton Robot. <i>IEEE International   Conference on Systems,  Man and Cybernetics proceedings</i>,  4,    984-988,  1999.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S1909-9762201000010000800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="21">21</a>&#93; Perry J.C.,  Rosen J. Design of a 7 degree-of-freedom upperlimb   powered exoskeleton. <i>IEEE International Conference on   Biomedical Robotics and Biomechatronics</i>,  Pisa,  Tuscany,  Italy,    February 20-22 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S1909-9762201000010000800021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="22">22</a>&#93; Steger R.,  Kim S.H.,  Kazerooni H. Control Scheme and   Networked Control Architecture for the Berkeley Lower   Extremity Exoskeleton. <i>IEEE International Conference On   Robotics And Automation</i>,  Orlando,  Florida,  May 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S1909-9762201000010000800022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="23">23</a>&#93; Chu A.,  Kazerooni H.,  Zoss A. On the biomimetic design of the   Berkeley Lower Extremity Exoskeleton. <i>IEEE International   Conference on Robotics and Automation</i>,  Barcelona,  Spain,  April   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S1909-9762201000010000800023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="24">24</a>&#93; Zoss A.,  Kazerooni H.,  Chu A. On the mechanical design of the   Berkeley Lower Extremity Exoskeleton. <i>IEEE International   Conference on Robotics and Automation</i>,  August 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S1909-9762201000010000800024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="25">25</a>&#93; Kazerooni H.,  Racine J.L.,  Huang L.,  Steger R. On the Control of   the Berkeley Lower Extremity Exoskeleton. <i>IEEE International   Conference on Robotics and Automation</i>,  Barcelona,  Spain,  April   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S1909-9762201000010000800025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="26">26</a>&#93; Kazerooni H. Exoskeletons for Human Power Augmentation.   <i>IEEE/RSJ International Conference on Intelligent Robots and   Systems</i>,  August 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S1909-9762201000010000800026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="27">27</a>&#93; Walsh C.J. Biomimetic design of an under-actuated leg   exoskeleton for load-carrying augmentation. <i>Master of Science's   thesis</i>,  Massachusetts Institute of Technology,  February 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S1909-9762201000010000800027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="28">28</a>&#93; Walsh C.J.,  Paluska D.,  Pasch K.,  Grand W.,  Valiente A.,  Herr   H. Development of a lightweight,  underactuated exoskeleton for   load-carrying augmentation. <i>IEEE International Conference on   Robotics And Automation</i>,  Orlando,  Florida,  May 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S1909-9762201000010000800028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="29">29</a>&#93; Amundson K.,  Raade J.,  Harding N.,  Kazerooni H. Hybrid   hydraulic-electric power unit for field and service robots. <i>IEEE   International Conference on Intelligent Robots and Systems</i>,    Edmonton,  Canada,  August 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S1909-9762201000010000800029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="30">30</a>&#93; Chen J.,  Liao W. A leg exoskeleton utilizing a   magnetorheological actuator. <i>IEEE International Conference On   Robotics And Biomimetics</i>,  Kunming,  China,  December 17 - 20   2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S1909-9762201000010000800030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="31">31</a>&#93; Dollar A.M.,  Herr H. Design of a quasi-passive knee exoskeleton   to assist running. <i>IEEE International Conference on Intelligent   Robots and Systems</i>,  Nice,  France,  September 22-26 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000135&pid=S1909-9762201000010000800031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="32">32</a>&#93; Weinberg B.,  Nikitczuk J.,  Patel S.,  Patritti B.,  Mavroidis C.,    Bonato P.,  Canavan P. Design,  control and human testing of an   active knee rehabilitation orthotic device. <i>IEEE International   Conference on Robotics and Automation</i>,  Roma,  Italia,  April 10-14 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000137&pid=S1909-9762201000010000800032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="33">33</a>&#93; Brutovsk&yacute; J.,  Nov&aacute;k D. Low-cost motivated rehabilitation   system for post-operation exercises. <i>Engineering in Medicine and   Biology Society (EMBS) 28th Annual International Conference of   the IEEE</i>,  New York,  August 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S1909-9762201000010000800033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="34">34</a>&#93; Singla E.,  Dasgupta B.,  Kondak K.,  Fleischer C.,  Hommel G.   Optimal design of an exoskeleton hip using three-degrees-offreedom   spherical mechanism. <i>ISR/ROBOTIK 2006 - Joint   conference on robotics</i>,  M&uuml;nich,  2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000141&pid=S1909-9762201000010000800034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="35">35</a>&#93; Urdaniz M.V.,  Ortiz M.A.,  Bonardi A.A.,  Gentiletti G.G. Dise&ntilde;o   y Simulaci&oacute;n de una &Oacute;rtesis Rob&oacute;tica para Rehabilitaci&oacute;n de la   Marcha. <i>XVII Congreso Argentino de Bioingenier&iacute;a</i>,  Rosario,    2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000143&pid=S1909-9762201000010000800035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="36">36</a>&#93; Pons J.L.,  Moreno J.C.,  Brunetti F.J.,  Rocon E. Lower-Limb   Wearable Exoskeleton. <i>Rehabilitation Robotics,  Ed. I-Tech   Education and Publishing</i>,  471-498,  2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000145&pid=S1909-9762201000010000800036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="37">37</a>&#93; Veneman J.F.,  Kruidhof R.,  Hekman E.E.G.,  Ekkelenkamp R.,    Van Asseldonk E.H.F.,  Van der Kooij H. Design and evaluation   of the LOPES exoskeleton robot for interactive gait rehabilitation.   <i>IEEE Transactions on Neural Systems and Rehabilitation   Engineering</i>,  15(3),  379-386,  September 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000147&pid=S1909-9762201000010000800037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="38">38</a>&#93; Valiente A. Design of a quasi-passive parallel leg exoskeleton to   augment load carrying for walking. <i>Master of Science's Thesis</i>,    Massachusetts Institute of Technology,  August 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000149&pid=S1909-9762201000010000800038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="39">39</a>&#93; Rosero E.E. Dise&ntilde;o y Construcci&oacute;n de una M&aacute;quina de   Movimiento Pasivo Continuo para la Terapia de Rodilla. <i>Tesis   para el t&iacute;tulo de Ingeniero Mec&aacute;nico</i>. Universidad del Valle,  2001.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000151&pid=S1909-9762201000010000800039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="40">40</a>&#93; Dariush B. Analysis and Simulation of an Exoskeleton   Controller that Accommodates Static and Reactive Loads.   <i>IEEE International Conference On Robotics And Automation</i>,    Barcelona,  Spain,  April 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000153&pid=S1909-9762201000010000800040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="41">41</a>&#93; Ghafari A.S.,  Meghdari A.,  Vossoughi G. R. Intelligent control   of powered exoskeleton to assist paraplegic patients mobility   using hybrid neuro-fuzzy ANFIS approach. <i>IEEE International   Conference on Robotics and Biomimetics</i>,  Kunming,  China,    December 17 - 20 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000155&pid=S1909-9762201000010000800041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="42">42</a>&#93; Agrawal S.K.,  Banala S.K.,  Fattah A. A gravity balancing passive   exoskeleton for the human leg. <i>Proceedings of Robotics: Science   and Systems</i>. Philadelphia,  USA,  August 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000157&pid=S1909-9762201000010000800042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="43">43</a>&#93; Villarejo J.J. <i>Detecci&oacute;n de la intenci&oacute;n de movimiento durante la   marcha a partir de se&ntilde;ales electromiogr&aacute;ficas</i>. Tesis de Grado.   Universidad del Valle,  Ingenier&iacute;a Electr&oacute;nica,  2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000159&pid=S1909-9762201000010000800043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="44">44</a>&#93; R&iacute;os A.E. Sistema microcontrolado para el desarrollo de pr&oacute;tesis   mioel&eacute;ctricos con realimentaci&oacute;n sensorial. Tesis de Grado.   Universidad Javeriana,  Ingenier&iacute;a Electr&oacute;nica,  2001.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000161&pid=S1909-9762201000010000800044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="45">45</a>&#93; Bureau M.,  Eizmendi G.,  Olaiz E.,  Zabaleta H.,  Medina J.,  P&eacute;rez   M. Dise&ntilde;o de un nuevo exoesqueleto para neuro-rehabilitaci&oacute;n   basado en detecci&oacute;n de intenci&oacute;n. <i>II Congreso Internacional   sobre Dom&oacute;tica,  Rob&oacute;tica y Teleasistencia para todos</i>,  Madrid,    Espa&ntilde;a,  Abril 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000163&pid=S1909-9762201000010000800045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="46">46</a>&#93; Kiguchi K.,  Tanakal T.,  Watanabe K.,  Fukuda T. Design and control   of an exoskeleton system for human upper-limb motion assist.   <i>Proceedings of the 2003 IEEE/ASME International Conference on   Advanced Intelligent Mechatronics</i>,  Kobe,  Japan,  July 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000165&pid=S1909-9762201000010000800046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="47">47</a>&#93; Fleischer C.,  Hommel G. Torque control of an exoskeletal knee   with EMG signals. <i>Proceedings of the Joint Conference on   Robotics</i>,  2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000167&pid=S1909-9762201000010000800047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="48">48</a>&#93; Rosen J.,  Brand M.,  Fuchs M.B.,  Arcan M. A myosignal-based   powered exoskeleton system. <i>IEEE Transaction on Systems,  Man,    And Cybernetics-Part A: Systems And Humans</i>,  31(3),  210-222,    May 2001.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000169&pid=S1909-9762201000010000800048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="49">49</a>&#93; Kawainoto H.,  Lee S.,  Kanbe S,  Sankai Y. Power assist method   for HAL-3 using EMG-based feedback controller. <i>Proceedings   of the IEEE International Conference on Systems,  Man and   Cybernetics</i>,  1648-1653,  2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000171&pid=S1909-9762201000010000800049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>&#91;<a name="50">50</a>&#93; Hommel G.,  Huanye S. Embedded systems modeling-technology and applications. Springer,  2006,  177-185.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000173&pid=S1909-9762201000010000800050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p> </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of an exoskeleton for index finger rehabilitation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[31 Annual International Conference of the IEEE-EMBS]]></conf-name>
<conf-date>September 2009</conf-date>
<conf-loc>Minneapolis Minneapolis</conf-loc>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wege]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kondak]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hommel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical design and motion control of a hand exoskeleton for rehabilitation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE Conference on Mechatronics and Automation (ICMA)]]></conf-name>
<conf-date>July-August 2005</conf-date>
<conf-loc>Canada Ontario</conf-loc>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shields]]></surname>
<given-names><![CDATA[B. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Main]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Peterson]]></surname>
<given-names><![CDATA[S.W.]]></given-names>
</name>
<name>
<surname><![CDATA[Strauss]]></surname>
<given-names><![CDATA[A.M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An anthropomorphic hand exoskeleton to prevent astronaut hand fatigue during extravehicular activities]]></article-title>
<source><![CDATA[IEEE Transactions on Systems, Man and Cybernetics, Part A: Systems And Humans]]></source>
<year>1997</year>
<volume>27</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>668-673</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koyama]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Yamano]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Takemura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Maeno]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multi-fingered exoskeleton haptic device using passive force feedback for dexterous teleoperation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ Intl. Conference of Intelligent Robots and Systems]]></conf-name>
<conf-date>October 2002</conf-date>
<conf-loc>Lausanne </conf-loc>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stergiopoulos]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Fuchs]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Laurgeau]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of a 2-finger hand exoskeleton for VR grasping simulation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ EuroHaptics]]></conf-name>
<conf-date>July 2003</conf-date>
<conf-loc>Dublin </conf-loc>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bouzit]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Burdea]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Popescu]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Boian]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The rutgers master II-new design force-feedback glove]]></article-title>
<source><![CDATA[IEEE/Asme Transactions on Mechatronics]]></source>
<year>2002</year>
<volume>7</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>256-263</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[B.H]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[H.R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A semi-direct drive hand exoskeleton using ultrasonic motor]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Workshop on Robot And Human Interaction]]></conf-name>
<conf-date>September 1999</conf-date>
<conf-loc>Pisa </conf-loc>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amat]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Frigola]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Casals]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental Robotics VII]]></article-title>
<source><![CDATA[Virtual exoskeleton for telemanipulation]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Anzola]]></surname>
<given-names><![CDATA[J.N]]></given-names>
</name>
<name>
<surname><![CDATA[Barrero]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Sistemas de Captura de Movimiento-EXOC AP: Loop de Animación]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Molina]]></surname>
<given-names><![CDATA[J.E]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[J.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Desarrollo de un sistema de control de un exoesqueleto para asistencia del movimiento del codo]]></article-title>
<source><![CDATA[Scientia et Technica]]></source>
<year>sept</year>
<month>ie</month>
<day>mb</day>
<volume>39</volume>
<page-range>129-134</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Molina]]></surname>
<given-names><![CDATA[J.E]]></given-names>
</name>
<name>
<surname><![CDATA[Orozco]]></surname>
<given-names><![CDATA[A.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Desarrollo de un sistema de control para asistencia del movimiento humano tipo flexión-extensión del brazo, para el desarrollo de exoesqueletos]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chou]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Xiao]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Haptic interaction with virtual environment using an arm type exoskeleton device]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>April 2004</conf-date>
<conf-loc>New Orleans </conf-loc>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mistry]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mohajerian]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Schaal]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Arm movement experiments with joint space force fields using an exoskeleton robot]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[9 International Conference on Rehabilitation Robotics]]></conf-name>
<conf-date>June 28-July 1 2005</conf-date>
<conf-loc>Chicago Illinois</conf-loc>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsagarakis]]></surname>
<given-names><![CDATA[N.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Caldwell]]></surname>
<given-names><![CDATA[D.G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A compliant exoskeleton for multi-planar upper limb physiotherapy and training]]></article-title>
<source><![CDATA[Advanced Robotics]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Niño-Suarez]]></surname>
<given-names><![CDATA[P.A]]></given-names>
</name>
<name>
<surname><![CDATA[Aviles-Sánchez]]></surname>
<given-names><![CDATA[O. F]]></given-names>
</name>
<name>
<surname><![CDATA[Vanegas]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Duque]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Exoesqueleto mecatrónico para rehabilitación motora]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[Octavo Congreso Iberoamericano de Ingenieria Mecanica]]></conf-name>
<conf-date>octubre 2007</conf-date>
<conf-loc>Cusco </conf-loc>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Papadopoulos]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Patsianis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of an exoskeleton mechanism for the shoulder joint]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[12 IFToMM World Congress]]></conf-name>
<conf-date>June 18-21 2007</conf-date>
<conf-loc>Besançon </conf-loc>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Agah]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bekey]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[IROS: An Intelligent Rehabilitative Orthotic System for cerebrovascular accident]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Systems, Man and Cybernetics Conference]]></conf-name>
<conf-date>November 1990</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sugar]]></surname>
<given-names><![CDATA[T.G]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Koeneman]]></surname>
<given-names><![CDATA[E.J]]></given-names>
</name>
<name>
<surname><![CDATA[Koeneman]]></surname>
<given-names><![CDATA[J.B]]></given-names>
</name>
<name>
<surname><![CDATA[Herman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Schultz]]></surname>
<given-names><![CDATA[R.S]]></given-names>
</name>
<name>
<surname><![CDATA[Herring]]></surname>
<given-names><![CDATA[D.E]]></given-names>
</name>
<name>
<surname><![CDATA[Wanberg]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Balasubramanian]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Swenson]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[J.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design and Control of RUPERT: A device for Robotic Upper Extremity Repetitive Therapy]]></article-title>
<source><![CDATA[IEEE Transactions on Neural Systems And Rehabilitation Engineering]]></source>
<year>Sept</year>
<month>em</month>
<day>be</day>
<volume>15</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>336-46</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kiguchi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Kariya]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Izumi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Fukuda]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An exoskeletal robot for human elbow motion support-sensor fusion, adaptation, and control]]></article-title>
<source><![CDATA[IEEE Transactions On Systems, Man, And Cybernetics-Part B: Cybernetics]]></source>
<year>June</year>
<month> 2</month>
<day>00</day>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>353-61</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Umetani]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yamada]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Morizono]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshida]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Aoki]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA["Skil Mate", Wearable Exoskeleton Robot]]></article-title>
<source><![CDATA[IEEE International Conference on Systems, Man and Cybernetics proceedings]]></source>
<year>1999</year>
<volume>4</volume>
<page-range>984-988</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Perry]]></surname>
<given-names><![CDATA[J.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Rosen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of a 7 degree-of-freedom upperlimb powered exoskeleton]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Biomedical Robotics and Biomechatronics]]></conf-name>
<conf-date>February 20-22 2006</conf-date>
<conf-loc>Pisa Tuscany</conf-loc>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steger]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[S.H]]></given-names>
</name>
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Control Scheme and Networked Control Architecture for the Berkeley Lower Extremity Exoskeleton]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference On Robotics And Automation]]></conf-name>
<conf-date>May 2006</conf-date>
<conf-loc>Orlando Florida</conf-loc>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zoss]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the biomimetic design of the Berkeley Lower Extremity Exoskeleton]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>April 2005</conf-date>
<conf-loc>Barcelona </conf-loc>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zoss]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Chu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the mechanical design of the Berkeley Lower Extremity Exoskeleton]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>August 2005</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Racine]]></surname>
<given-names><![CDATA[J.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Steger]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the Control of the Berkeley Lower Extremity Exoskeleton]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>April 2005</conf-date>
<conf-loc>Barcelona </conf-loc>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exoskeletons for Human Power Augmentation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE/RSJ International Conference on Intelligent Robots and Systems]]></conf-name>
<conf-date>August 2005</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walsh]]></surname>
<given-names><![CDATA[C.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomimetic design of an under-actuated leg exoskeleton for load-carrying augmentation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walsh]]></surname>
<given-names><![CDATA[C.J]]></given-names>
</name>
<name>
<surname><![CDATA[Paluska]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Pasch]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Grand]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Valiente]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Herr]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development of a lightweight, underactuated exoskeleton for load-carrying augmentation]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics And Automation]]></conf-name>
<conf-date>May 2006</conf-date>
<conf-loc>Orlando Florida</conf-loc>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amundson]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Raade]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Harding]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Kazerooni]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hybrid hydraulic-electric power unit for field and service robots]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Intelligent Robots and Systems]]></conf-name>
<conf-date>August 2005</conf-date>
<conf-loc>Edmonton </conf-loc>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Liao]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A leg exoskeleton utilizing a magnetorheological actuator]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference On Robotics And Biomimetics]]></conf-name>
<conf-date>December 17 - 20 2006</conf-date>
<conf-loc>Kunming </conf-loc>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dollar]]></surname>
<given-names><![CDATA[A.M]]></given-names>
</name>
<name>
<surname><![CDATA[Herr]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of a quasi-passive knee exoskeleton to assist running]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Intelligent Robots and Systems]]></conf-name>
<conf-date>September 22-26 2008</conf-date>
<conf-loc>Nice </conf-loc>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weinberg]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Nikitczuk]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Patel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Patritti]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Mavroidis]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bonato]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Canavan]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design, control and human testing of an active knee rehabilitation orthotic device]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>April 10-14 2007</conf-date>
<conf-loc>Roma </conf-loc>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brutovský]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Novák]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Low-cost motivated rehabilitation system for post-operation exercises]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[28 Annual International Conference of the IEEE]]></conf-name>
<conf-date>August 2006</conf-date>
<conf-loc>New York </conf-loc>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Singla]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Dasgupta]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Kondak]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Fleischer]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hommel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimal design of an exoskeleton hip using three-degrees-offreedom spherical mechanism]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ ISR/ROBOTIK 2006 - Joint conference on robotics]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc>Münich </conf-loc>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Urdaniz]]></surname>
<given-names><![CDATA[M.V]]></given-names>
</name>
<name>
<surname><![CDATA[Ortiz]]></surname>
<given-names><![CDATA[M.A]]></given-names>
</name>
<name>
<surname><![CDATA[Bonardi]]></surname>
<given-names><![CDATA[A.A]]></given-names>
</name>
<name>
<surname><![CDATA[Gentiletti]]></surname>
<given-names><![CDATA[G.G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Diseño y Simulación de una Órtesis Robótica para Rehabilitación de la Marcha]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[XVII Congreso Argentino de Bioingeniería]]></conf-name>
<conf-date>2009</conf-date>
<conf-loc>Rosario </conf-loc>
</nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pons]]></surname>
<given-names><![CDATA[J.L]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno]]></surname>
<given-names><![CDATA[J.C]]></given-names>
</name>
<name>
<surname><![CDATA[Brunetti]]></surname>
<given-names><![CDATA[F.J]]></given-names>
</name>
<name>
<surname><![CDATA[Rocon]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Lower-Limb Wearable Exoskeleton]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Veneman]]></surname>
<given-names><![CDATA[J.F]]></given-names>
</name>
<name>
<surname><![CDATA[Kruidhof]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hekman]]></surname>
<given-names><![CDATA[E.E.G]]></given-names>
</name>
<name>
<surname><![CDATA[Ekkelenkamp]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Van Asseldonk]]></surname>
<given-names><![CDATA[E.H.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Van der Kooij]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation]]></article-title>
<source><![CDATA[IEEE Transactions on Neural Systems and Rehabilitation Engineering]]></source>
<year>Sept</year>
<month>em</month>
<day>be</day>
<volume>15</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>379-386</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valiente]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design of a quasi-passive parallel leg exoskeleton to augment load carrying for walking]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosero]]></surname>
<given-names><![CDATA[E.E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Diseño y Construcción de una Máquina de Movimiento Pasivo Continuo para la Terapia de Rodilla]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dariush]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis and Simulation of an Exoskeleton Controller that Accommodates Static and Reactive Loads]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference On Robotics And Automation]]></conf-name>
<conf-date>April 2005</conf-date>
<conf-loc>Barcelona </conf-loc>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghafari]]></surname>
<given-names><![CDATA[A.S]]></given-names>
</name>
<name>
<surname><![CDATA[Meghdari]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vossoughi]]></surname>
<given-names><![CDATA[G. R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intelligent control of powered exoskeleton to assist paraplegic patients mobility using hybrid neuro-fuzzy ANFIS approach]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Biomimetics]]></conf-name>
<conf-date>December 17 - 20 2006</conf-date>
<conf-loc>Kunming </conf-loc>
</nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Agrawal]]></surname>
<given-names><![CDATA[S.K]]></given-names>
</name>
<name>
<surname><![CDATA[Banala]]></surname>
<given-names><![CDATA[S.K]]></given-names>
</name>
<name>
<surname><![CDATA[Fattah]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A gravity balancing passive exoskeleton for the human leg]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ Proceedings of Robotics: Science and Systems]]></conf-name>
<conf-date>August 2006</conf-date>
<conf-loc>Philadelphia </conf-loc>
</nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Villarejo]]></surname>
<given-names><![CDATA[J.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Detección de la intención de movimiento durante la marcha a partir de señales electromiográficas]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ríos]]></surname>
<given-names><![CDATA[A.E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistema microcontrolado para el desarrollo de prótesis mioeléctricos con realimentación sensorial]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bureau]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Eizmendi]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Olaiz]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Zabaleta]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Medina]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Diseño de un nuevo exoesqueleto para neuro-rehabilitación basado en detección de intención]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[II Congreso Internacional sobre Domótica, Robótica y Teleasistencia para todos]]></conf-name>
<conf-date>Abril 2007</conf-date>
<conf-loc>Madrid </conf-loc>
</nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kiguchi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Tanakal]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Fukuda]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design and control of an exoskeleton system for human upper-limb motion assist]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics]]></conf-name>
<conf-date>July 2003</conf-date>
<conf-loc>Kobe </conf-loc>
</nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fleischer]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hommel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Torque control of an exoskeletal knee with EMG signals]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ Joint Conference on Robotics]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Brand]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fuchs]]></surname>
<given-names><![CDATA[M.B]]></given-names>
</name>
<name>
<surname><![CDATA[Arcan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A myosignal-based powered exoskeleton system]]></article-title>
<source><![CDATA[IEEE Transaction on Systems, Man, And Cybernetics-Part A: Systems And Humans]]></source>
<year>May </year>
<month>20</month>
<day>01</day>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>210-222</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kawainoto]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kanbe]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sankai]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power assist method for HAL-3 using EMG-based feedback controller]]></article-title>
<source><![CDATA[Proceedings of the IEEE International Conference on Systems, Man and Cybernetics]]></source>
<year>2003</year>
<page-range>1648-1653</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hommel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Huanye]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Embedded systems modeling-technology and applications]]></source>
<year></year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>