<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1909-9762</journal-id>
<journal-title><![CDATA[Revista Ingeniería Biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. ing. biomed.]]></abbrev-journal-title>
<issn>1909-9762</issn>
<publisher>
<publisher-name><![CDATA[Fondo Editorial EIA, Escuela de Ingeniería de Antioquia EIA-, Universidad CES]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1909-97622013000100004</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[MODELO PARAMÉTRICO DE LA ACTIVIDAD ELÉCTRICA CELULAR CARDIACA ESTIMADO A PARTIR DE REGISTROS ELECTROCARDIOGRÁFICOS ESTÁNDARES]]></article-title>
<article-title xml:lang="en"><![CDATA[PARAMETRICAL MODEL OF CARDIAC CELL ELECTRICAL ACTIVITY ESTIMATED FROM STANDARD ELECTROCARDIOGRAM RECORDINGS]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Illanes]]></surname>
<given-names><![CDATA[Alfredo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sérandour]]></surname>
<given-names><![CDATA[Guillaume]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Austral de Chile Facultad de Ciencias de la Ingeniería ]]></institution>
<addr-line><![CDATA[Valdivia ]]></addr-line>
<country>Chile</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Austral de Chile Facultad de Ciencias de la Ingeniería ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2013</year>
</pub-date>
<volume>7</volume>
<numero>13</numero>
<fpage>31</fpage>
<lpage>42</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S1909-97622013000100004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S1909-97622013000100004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S1909-97622013000100004&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El presente trabajo tiene como objetivo principal relacionar la actividad eléctrica cardiaca celular con la actividad eléctrica cardiaca medida en una sola derivación del electrocardiograma (ECG), mediante un modelo paramétrico de potencial de acción (PA) celular, lo cual se llevó a cabo relacionando dinámicas conocidas, matemáticamente modelables, que existen a nivel de una célula cardiaca, a dinámicas que pueden ser encontradas en un registro ECG estándar. La principal dinámica celular a relacionar con el ECG es la conocida como curva de restitución celular en tres dimensiones, la cual relaciona la duración del potencial de acción celular (APD) con el intervalo diastólico que lo precede y con el mismo APD pero del ciclo cardiaco precedente. Curvas de restitución similares se encontraron en señales ECG registradas durante el test isométrico handgrip, relacionando el intervalo QT con el intervalo TQ que lo precede y con el intervalo QT del ciclo cardiaco precedente. Siguiendo esta similitud, un modelo paramétrico de curva de restitución, extraído de un modelo de PA a tres corrientes iónicas, es ajustado a la curva de restitución del ECG con el fin de estimar los parámetros del modelo de PA. Este modelo es finalmente simulado estimulándolo con un tren de impulsos de frecuencia igual a la frecuencia cardiaca del sujeto experimentado. Los resultados muestran que la curva de restitución obtenida experimentalmente a partir del ECG es similar a la obtenida a partir de la simulación del modelo de PA. Más aún, el APD simulado del modelo sigue de forma satisfactoria la variación en el tiempo del intervalo QT del sujeto experimentado. Esto abre nuevas perspectivas en el análisis de la actividad celular a partir de registros ECG estándar.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The main purpose of this paper is to relate cellular cardiac electrical activity with the cardiac electrical activity measured in only one electrocardiogram (ECG) lead, through a cellular action potential (AP) parametrical model. This is performed by relating known dynamics, which can be mathematically modeled, existing at a cardiac cell level, to dynamics which can be obtained from a standard ECG recording. The main cellular dynamic used for relating with the ECG is the one known as three dimensional cellular restitution curve, which relates the action potential duration (APD) with its preceding diastolic interval and with the APD of the preceding cardiac cycle. Similar restitution curves were found in ECG signals recorded under the isometric handgrip test by relating the QT interval with its preceding TQ interval and with the QT interval of the preceding cardiac cycle. Following this similarity, a parametrical restitution curve, derived from a three ionic current cellular AP model was fitted to the ECG restitution relation for AP model parameter estimation. This model is finally simulated by stimulating it with an impulse train of frequency similar to the heart rate of the tested subject. The results show that the restitution curve experimentally obtained from the ECG is similar to the one obtained from de AP model simulation. Moreover the simulated APD follows satisfactorily the QT interval time variation of the tested subject. This opens new perspectives for the analysis of cellular cardiac electrical activity from standard ECG recordings.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Modelado ECG]]></kwd>
<kwd lng="es"><![CDATA[modelo de potencial de acción celular]]></kwd>
<kwd lng="es"><![CDATA[intervalo QT]]></kwd>
<kwd lng="es"><![CDATA[APD]]></kwd>
<kwd lng="es"><![CDATA[curva de restitución]]></kwd>
<kwd lng="en"><![CDATA[ECG modelling]]></kwd>
<kwd lng="en"><![CDATA[cellular action potential model]]></kwd>
<kwd lng="en"><![CDATA[QT interval]]></kwd>
<kwd lng="en"><![CDATA[APD]]></kwd>
<kwd lng="en"><![CDATA[restitution curve]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">          <p align="center"><font size="4"><b>MODELO PARAM&Eacute;TRICO DE LA ACTIVIDAD EL&Eacute;CTRICA CELULAR CARDIACA ESTIMADO A PARTIR DE REGISTROS ELECTROCARDIOGR&Aacute;FICOS EST&Aacute;NDARES</b></font></p>     <p align="center"><font size="3"><b>PARAMETRICAL MODEL OF CARDIAC CELL ELECTRICAL ACTIVITY ESTIMATED FROM STANDARD ELECTROCARDIOGRAM RECORDINGS</b></font></p>     <p>&nbsp;</p>     <p><b>Alfredo Illanes<sup>1,2</sup>, Guillaume S&eacute;randour<sup>1</sup></b></p>          <p><i>1 Facultad de Ciencias de la Ingenier&iacute;a, Universidad Austral de Chile, Valdivia, Chile.    <br> 2 Direcci&oacute;n para correspondencia: <a href="mailto:alfredoillanes@uach.cl">alfredoillanes@uach.cl</a>.</i></p>     <p>Recibido 1 de febrero de 2013. Aprobado 10 de abril de 2013</p> <hr size="1" />              <p>&nbsp;</p>     <p><b><font size="3">RESUMEN</font></b></p>     ]]></body>
<body><![CDATA[<p>El presente trabajo tiene como objetivo principal relacionar la actividad el&eacute;ctrica cardiaca celular con la actividad   el&eacute;ctrica cardiaca medida en una sola derivaci&oacute;n del electrocardiograma (ECG), mediante un modelo param&eacute;trico de potencial de   acci&oacute;n (PA) celular, lo cual se llev&oacute; a cabo relacionando din&aacute;micas conocidas, matem&aacute;ticamente modelables, que existen a nivel de   una c&eacute;lula cardiaca, a din&aacute;micas que pueden ser encontradas en un registro ECG est&aacute;ndar. La principal din&aacute;mica celular a relacionar   con el ECG es la conocida como curva de restituci&oacute;n celular en tres dimensiones, la cual relaciona la duraci&oacute;n del potencial de acci&oacute;n   celular (APD) con el intervalo diast&oacute;lico que lo precede y con el mismo APD pero del ciclo cardiaco precedente. Curvas de restituci&oacute;n   similares se encontraron en se&ntilde;ales ECG registradas durante el test isom&eacute;trico <i>handgrip</i>, relacionando el intervalo QT con el intervalo   TQ que lo precede y con el intervalo QT del ciclo cardiaco precedente. Siguiendo esta similitud, un modelo param&eacute;trico de curva de   restituci&oacute;n, extra&iacute;do de un modelo de PA a tres corrientes i&oacute;nicas, es ajustado a la curva de restituci&oacute;n del ECG con el fin de estimar   los par&aacute;metros del modelo de PA. Este modelo es finalmente simulado estimul&aacute;ndolo con un tren de impulsos de frecuencia igual a la   frecuencia cardiaca del sujeto experimentado. Los resultados muestran que la curva de restituci&oacute;n obtenida experimentalmente a partir   del ECG es similar a la obtenida a partir de la simulaci&oacute;n del modelo de PA. M&aacute;s a&uacute;n, el APD simulado del modelo sigue de forma   satisfactoria la variaci&oacute;n en el tiempo del intervalo QT del sujeto experimentado. Esto abre nuevas perspectivas en el an&aacute;lisis de la actividad celular a partir de registros ECG est&aacute;ndar.</p>          <p><font size="3"><b>PALABRAS CLAVE</b></font>: Modelado ECG, modelo de potencial de acci&oacute;n celular, intervalo QT, APD, curva de restituci&oacute;n.</p>  <hr size="1" />              <p>&nbsp;</p>     <p><font size="3"><b>ABSTRACT</b></font></p>     <p>The main purpose of this paper is to relate cellular cardiac electrical activity with the cardiac electrical activity measured   in only one electrocardiogram (ECG) lead, through a cellular action potential (AP) parametrical model. This is performed by relating   known dynamics, which can be mathematically modeled, existing at a cardiac cell level, to dynamics which can be obtained from a   standard ECG recording. The main cellular dynamic used for relating with the ECG is the one known as three dimensional cellular   restitution curve, which relates the action potential duration (APD) with its preceding diastolic interval and with the APD of the   preceding cardiac cycle. Similar restitution curves were found in ECG signals recorded under the isometric <i>handgrip</i> test by relating   the QT interval with its preceding TQ interval and with the QT interval of the preceding cardiac cycle. Following this similarity, a   parametrical restitution curve, derived from a three ionic current cellular AP model was fitted to the ECG restitution relation for AP   model parameter estimation. This model is finally simulated by stimulating it with an impulse train of frequency similar to the heart rate   of the tested subject. The results show that the restitution curve experimentally obtained from the ECG is similar to the one obtained   from de AP model simulation. Moreover the simulated APD follows satisfactorily the QT interval time variation of the tested subject. This opens new perspectives for the analysis of cellular cardiac electrical activity from standard ECG recordings.</p>     <p><font size="3"><b>KEY WORDS</b></font>: ECG modelling, cellular action potential model, QT interval, APD, restitution curve.</p>  <hr size="1" />           <p>&nbsp;</p>       <p><font size="3"><b>I. INTRODUCCI&Oacute;N</b></font></p>          <p>El electrocardiograma (ECG) posee un gran valor   cl&iacute;nico para el diagn&oacute;stico de trastornos del ritmo   y de la conducci&oacute;n el&eacute;ctrica cardiacos. &Eacute;ste describe la   actividad el&eacute;ctrica del coraz&oacute;n captada por electrodos (al   menos dos) localizados en la superficie del cuerpo. Cada   ciclo cardiaco se caracteriza en el ECG por una sucesi&oacute;n   de eventos conocidos como la onda P, el complejo QRS   y la onda T. Los intervalos de tiempo entre inicios y   t&eacute;rminos de estos distintos eventos son importantes para   el diagn&oacute;stico, pues reflejan procesos electrofisiol&oacute;gicos   que ocurren al interior del coraz&oacute;n y que por ende   entregan informaci&oacute;n significativa acerca de la actividad   el&eacute;ctrica cardiaca.</p>     <p>Aunque el ECG corresponde a un procedimiento   no-invasivo de adquisici&oacute;n de datos que permite acceder   a la din&aacute;mica global de la actividad el&eacute;ctrica del coraz&oacute;n,   la informaci&oacute;n obtenida de esta manera es dif&iacute;cil de   analizar. En efecto, esta informaci&oacute;n es el resultado de   una suma de actividades microsc&oacute;picas localizadas al   interior del cuerpo y transmitidas a trav&eacute;s de un medio   no homog&eacute;neo &#91;<a href="#1">1</a>,<a href="#2">2</a>&#93;; entre los electrodos y el coraz&oacute;n se   encuentran una diversidad de &oacute;rganos y tejidos. Es decir   que las se&ntilde;ales captadas en un registro electrocardiogr&aacute;fico   corresponden a una medida de la actividad el&eacute;ctrica   cardiaca a escala macrosc&oacute;pica que encuentra su origen   a escala microsc&oacute;pica, a nivel de potenciales celulares.   Esto hace que sea un problema complejo la extracci&oacute;n de   informaci&oacute;n de la actividad el&eacute;ctrica cardiaca celular a   partir de t&eacute;cnicas no invasivas como el ECG.</p>     ]]></body>
<body><![CDATA[<p>Diversos trabajos han tenido como objetivo el estudio   de esta compleja relaci&oacute;n entre la actividad el&eacute;ctrica   celular cardiaca y sus proyecciones en potenciales de   superficie del cuerpo a nivel ECG. En una primera   categor&iacute;a se encuentran trabajos que relacionan   experimentalmente intervalos del ECG con intervalos   medibles a nivel de potenciales de acci&oacute;n celular. En &#91;<a href="#3">3</a>&#93;   y &#91;<a href="#4">4</a>&#93; se estudiaron los efectos de la frecuencia cardiaca   sobre el intervalo QT del ECG. Ambos trabajos muestran   similitudes entre estos efectos y los producidos por la   frecuencia de excitaci&oacute;n del tejido cardiaco sobre la   duraci&oacute;n del potencial de acci&oacute;n celular. En los trabajos   presentados en &#91;<a href="#5">5</a>,<a href="#6">6</a>&#93; se realizaron estudios experimentales   acerca de la dependencia del intervalo QT con el intervalo   TQ del ECG y se encontraron relaciones similares con la   dependencia existente a nivel celular entre el intervalo   diast&oacute;lico y la duraci&oacute;n del potencial de acci&oacute;n.</p>     <p>Si bien los trabajos citados anteriormente ponen   en evidencia relaciones entre intervalos a nivel ECG e   intervalos a nivel celular, estos s&oacute;lo exploran el &aacute;mbito   experimental y no relacionan anal&iacute;ticamente ambos niveles   por medio de modelos matem&aacute;ticos. En este sentido cabe   mencionar el trabajo presentado en &#91;<a href="#7">7</a>&#93; donde un modelo   a dos variables de estado del potencial de acci&oacute;n celular   fue ajustado a se&ntilde;ales ECG por medio de una relaci&oacute;n de   restituci&oacute;n a dos dimensiones.</p>     <p>Un &aacute;rea de investigaci&oacute;n que aborda el estudio de la   relaci&oacute;n entre potenciales medidos a nivel de superficie   del cuerpo a potenciales celulares por medio de modelos   matem&aacute;ticos es el que concierne al problema inverso del   ECG. Este consiste en la caracterizaci&oacute;n de un modelo   matem&aacute;tico de la actividad el&eacute;ctrica celular cardiaca a   partir de se&ntilde;ales ECG &#91;<a href="#8">8</a>-<a href="#13">13</a>&#93;. En general el problema   directo (la generaci&oacute;n de se&ntilde;ales ECG a partir de un   modelo de actividad el&eacute;ctrica celular cardiaca) se resuelve   calculando una funci&oacute;n de transferencia que relaciona los   potenciales medidos a nivel de la superficie del cuerpo   con las fuentes localizadas al interior del coraz&oacute;n &#91;<a href="#8">8</a>,<a href="#10">10</a>&#93;.   Con el fin de resolver el problema inverso es necesario   invertir esta funci&oacute;n de transferencia. Este proceso de   inversi&oacute;n es generalmente complejo debido a que hay   menos informaci&oacute;n en las se&ntilde;ales ECG que la requerida   para la caracterizaci&oacute;n del modelo. Con el fin de superar   este problema es necesario utilizar un gran n&uacute;mero de   electrodos en la superficie del cuerpo con el fin de obtener   una mayor cantidad de observaciones (se&ntilde;ales ECG) &#91;<a href="#8">8</a>&#93;.   La desventaja de esta soluci&oacute;n es que se transforma en un   procedimiento que no es est&aacute;ndar, por lo cual no se puede   llevar a cabo con electrocardi&oacute;grafos convencionales.</p>     <p>El objetivo de este trabajo es relacionar la   actividad el&eacute;ctrica cardiaca celular con la actividad   el&eacute;ctrica cardiaca medida en una sola derivaci&oacute;n   del electrocardiograma (ECG), mediante un modelo   param&eacute;trico de potencial de acci&oacute;n (PA) celular, lo   cual se llev&oacute; a cabo relacionando din&aacute;micas conocidas,   matem&aacute;ticamente modelables, que existen a nivel de una   c&eacute;lula cardiaca, a din&aacute;micas que pueden ser encontradas a   nivel de un registro ECG est&aacute;ndar. El punto clave de este   enfoque es la relaci&oacute;n entre intervalos de tiempo medibles   en se&ntilde;ales ECG e intervalos definidos a nivel celular,   mediante un modelo param&eacute;trico de potencial de acci&oacute;n   (PA) celular cuyos par&aacute;metros pueden ser estimados a   partir de un registro ECG.</p>     <p>La principal din&aacute;mica celular que se quiere explotar   para relacionar ambas escalas es la relaci&oacute;n existente   entre la duraci&oacute;n del potencial de acci&oacute;n celular (APD) y   el intervalo diast&oacute;lico (DI), ambos par&aacute;metros utilizados   para describir la actividad el&eacute;ctrica y de reposo de una   c&eacute;lula respectivamente. En efecto, se ha logrado demostrar   en investigaciones tanto experimentales &#91;<a href="#14">14</a>-<a href="#18">18</a>&#93; como   anal&iacute;ticas &#91;<a href="#19">19</a>-<a href="#21">21</a>&#93; que el tejido cardiaco posee una   memoria que se ve reflejada en una relaci&oacute;n entre el APD   y el DI, tanto de ciclos presentes como de ciclos pasados.   De hecho, la relaci&oacute;n entre un APD y su DI que lo precede   directamente tiene una forma de onda bien definida   conocida como curva de restituci&oacute;n celular &#91;<a href="#18">18</a>, <a href="#20">20</a>-<a href="#22">22</a>&#93;.   Esta relaci&oacute;n de restituci&oacute;n ha sido largamente estudiada y   permite evaluar ciertas caracter&iacute;sticas del comportamiento   cardiaco, particularmente el riesgo de alternancias &#91;<a href="#21">21</a>,   <a href="#23">23</a>-<a href="#27">27</a>&#93;, un ritmo card&iacute;aco anormal, caracterizado por   variaciones en la duraci&oacute;n del APD entre dos ciclos   cardiacos y que podr&iacute;a estar detr&aacute;s de la activaci&oacute;n de   arritmias cardiacas de gravedad.</p>     <p>Se han encontrado igualmente relaciones de restituci&oacute;n   celulares en tres dimensiones, relacionando el APD   actual no solo a su DI precedente sino que tambi&eacute;n a su   APD precedente. Estas relaciones se han presentado tanto   en trabajos experimentales &#91;<a href="#28">28</a>, <a href="#29">29</a>&#93;, como en trabajos   anal&iacute;ticos &#91;<a href="#19">19</a>, <a href="#30">30</a>&#93;.</p>     <p>Los resultados obtenidos muestran que el APD   simulado del modelo sigue de forma satisfactoria la   variaci&oacute;n en el tiempo del intervalo QT del sujeto testeado,   lo cual abre nuevas perspectivas en el an&aacute;lisis de la   actividad celular a partir de registros ECG est&aacute;ndar.</p>     <p>Cabe se&ntilde;alar que algunos resultados preliminares de   este trabajo fueron presentados en &#91;<a href="#31">31</a>&#93;.</p>     <p><i><font size="3">1.1. La curva de restituci&oacute;n celular</font></i></p>     <p>El prop&oacute;sito de esta secci&oacute;n es introducir algunos   conceptos para una mejor comprensi&oacute;n del objetivo del   presente trabajo y sobre todo para entender los par&aacute;metros   que involucra la relaci&oacute;n de restituci&oacute;n a nivel celular.</p>     ]]></body>
<body><![CDATA[<p>Cuando un est&iacute;mulo el&eacute;ctrico de amplitud suficiente   llega a una c&eacute;lula excitable, el potencial al interior de   la c&eacute;lula se vuelve r&aacute;pidamente positivo con respecto   al exterior de &eacute;sta. Este proceso es conocido como   despolarizaci&oacute;n celular. El proceso inverso, cuando la   c&eacute;lula cardiaca estimulada vuelve a su estado de reposo,   se conoce como repolarizaci&oacute;n celular. El registro de   las diferencias de potencial medidas entre los medios   intracelulares y extracelulares durante los procesos de   despolarizaci&oacute;n-repolarizaci&oacute;n de una c&eacute;lula cardiaca   corresponde al potencial de acci&oacute;n celular (llamado   AP por la abreviaci&oacute;n en ingl&eacute;s de <i>Action Potential</i>). La   duraci&oacute;n de ambos procesos es conocido como la duraci&oacute;n   del potencial de acci&oacute;n (llamado APD por la abreviaci&oacute;n   en ingl&eacute;s de Action <i>Potential Duration</i>) y el intervalo   de tiempo entre el fin de la repolarizaci&oacute;n celular y la   llegada del pr&oacute;ximo est&iacute;mulo el&eacute;ctrico es conocido como   el intervalo diast&oacute;lico (llamado DI por la abreviaci&oacute;n   en ingl&eacute;s de <i>Diastolic Interval</i>). El APD y el DI est&aacute;n   relacionados por medio del periodo de excitaci&oacute;n celular   (llamado BCL por la abreviaci&oacute;n en ingl&eacute;s de <i>Basic   Cycle Length</i>) que corresponde al intervalo de tiempo   entre dos excitaciones sucesivas. Estos tres intervalos   (APD, DI, BCL), que se pueden observar en la <a href="#fig1">Fig. 1</a>, son   importantes para la comprensi&oacute;n del concepto de relaci&oacute;n   de restituci&oacute;n celular.</p>       <p align="center"><a name="fig1"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig1.gif"></p>     <p>Cuando el coraz&oacute;n late a una cierta frecuencia, el APD   debe ajustarse con el fin de asegurar un bombeo efectivo   de sangre. Un incremento de la frecuencia cardiaca   requiere una disminuci&oacute;n del APD y del DI, lo que resulta   en s&iacute;stoles y di&aacute;stoles el&eacute;ctricas m&aacute;s cortas. Para una   concordancia correcta entre las fases de llenado y eyecci&oacute;n   de los ventr&iacute;culos, las variaciones del APD y del DI est&aacute;n   fuertemente relacionadas. La din&aacute;mica de este proceso   se conoce como restituci&oacute;n el&eacute;ctrica. El comportamiento   din&aacute;mico de esta relaci&oacute;n ha sido estudiado en diversos   trabajos &#91;<a href="#14">14</a>-<a href="#18">18</a>, <a href="#26">26</a>, <a href="#32">32</a>&#93;.</p>     <p>Esta relaci&oacute;n de restituci&oacute;n puede ser descrita   matem&aacute;ticamente tanto para una relaci&oacute;n de restituci&oacute;n   a dos variables, entre el APD actual y su DI precedente   (<a href="#for1">1</a>), como para una relaci&oacute;n de restituci&oacute;n a tres variables,   entre el APD actual, el DI que lo precede y el APD del   ciclo precedente (<a href="#for1">2</a>):</p>       <p align="center"><a name="for1"></a><img src="img/revistas/rinbi/v7n13/v7n13a04for1.gif"></p>     <p>donde los sub&iacute;ndices <i>n</i> y <i>n + 1</i> denotan el n&uacute;mero de   ciclo cardiaco. La curva que representa esta relaci&oacute;n, tanto   en dos como en tres dimensiones, es la llamada curva de   restituci&oacute;n celular. Las funciones <i>f</i> y <i>g</i> de (<a href="#for1">1</a>) y (<a href="#for1">2</a>) son   generalmente determinadas de forma experimental. En la   literatura la mayor&iacute;a de los modelos emp&iacute;ricos de la curva   de restituci&oacute;n tienen una forma exponencial &#91;<a href="#22">22</a>, <a href="#33">33</a>&#93;.</p>     <p>Diversos protocolos de excitaci&oacute;n celular han   sido utilizados con el objetivo de registrar la curva de   restituci&oacute;n celular. Los m&aacute;s utilizados son los conocidos   como protocolo S1-S2 y protocolo din&aacute;mico. El primero   consiste en enviar una secuencia de impulsos a un BCL   constante para enseguida enviar un est&iacute;mulo prematuro   individual &#91;<a href="#15">15</a>&#93;. El segundo consiste primeramente   en excitar la c&eacute;lula a un BCL constante y enseguida,   cuando todos los transitorios se hayan desvanecido,   progresivamente disminuir el BCL &#91;<a href="#17">17</a>&#93;.</p>     <p>La importancia de la curva de restituci&oacute;n en la   caracterizaci&oacute;n de din&aacute;micas cardiacas ha sido enfatizada   en numerosos estudios &#91;<a href="#29">29</a>, <a href="#30">30</a>&#93;. Es conocido que la   restituci&oacute;n del APD es de importancia fundamental en   din&aacute;micas cardiacas. En particular, la pendiente de la   curva de restituci&oacute;n est&aacute; relacionada a la ocurrencia de   alternancias &#91;<a href="#21">21</a>, <a href="#22">22</a>, <a href="#33">33</a>, <a href="#34">34</a>&#93;, un ritmo cardiaco anormal   que se caracteriza por din&aacute;micas de larga y corta duraci&oacute;n   del APD y que pueden estar detr&aacute;s de ciertas patolog&iacute;as   cardiacas &#91;<a href="#23">23</a>, <a href="#24">24</a>, <a href="#27">27</a>&#93;.</p>     <p>&nbsp;</p>     <p><b><font size="3">II. MATERIALES Y M&Eacute;TODOS</font></b> </p>     ]]></body>
<body><![CDATA[<p>En esta secci&oacute;n se detalla la metodolog&iacute;a y el   procedimiento de adquisici&oacute;n de datos para estimar los   par&aacute;metros de un modelo de potencial de acci&oacute;n (PA) a   partir de una sola derivaci&oacute;n del ECG. Esta metodolog&iacute;a   y los registros utilizados son los mismos que en el trabajo   presentado en &#91;<a href="#7">7</a>&#93; pero ahora con el objetivo de obtener   curvas de restituci&oacute;n basadas en el ECG que poseen tres   dimensiones (ECG-RC3D), las cuales servir&aacute;n para   estimar los par&aacute;metros de un modelo a tres corrientes   i&oacute;nicas (en &#91;<a href="#7">7</a>&#93; se trabaj&oacute; con un modelo a dos corrientes   i&oacute;nicas).</p>     <p>Como se explic&oacute; en las secciones anteriores el   principal comportamiento din&aacute;mico de la actividad   el&eacute;ctrica celular considerada en este trabajo est&aacute;   caracterizado por la curva de restituci&oacute;n que relaciona los   APDs y DIs de distintos ciclos cardiacos. Con el fin de   relacionar actividades cardiacas observadas a nivel celular   y a nivel ECG, los intervalos QT y TQ son utilizados para   obtener relaciones de restituci&oacute;n a nivel ECG.</p>     <p>La analog&iacute;a entre intervalos a nivel celular y ECG   sobre la cual se basa este trabajo se ilustra en la <a href="#fig2">Fig. 2</a>.   Desde un punto de vista fisiol&oacute;gico, la representaci&oacute;n   mostrada por esta figura es incorrecta, sin embargo   explica intuitivamente la idea b&aacute;sica detr&aacute;s de este   estudio. Esta idea se apoya en el hecho de que el   intervalo QT est&aacute; relacionado con los APDs de un gran   n&uacute;mero de c&eacute;lulas, los cuales var&iacute;an de sitio en sitio en   los ventr&iacute;culos &#91;<a href="#34">34</a>, <a href="#35">35</a>&#93;.</p>       <p align="center"><a name="fig2"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig2.gif"></p>     <p>La <a href="#fig3">Fig. 3</a> resume las etapas para estimar los   par&aacute;metros del modelo de PA a tres corrientes i&oacute;nicas   a partir de un registro ECG de una derivaci&oacute;n. Estas   etapas ser&aacute;n presentadas en detalle en las pr&oacute;ximas   secciones. La se&ntilde;al ECG resultante del test <i>handgrip</i> entra primeramente a una etapa de segmentaci&oacute;n, a   partir de la cual se calculan los intervalos QT y TQ   para cada ciclo cardiaco. Luego se obtiene la ECG-RC3D   graficando, en la fase de contracci&oacute;n durante   el test del <i>handgrip</i>, el intervalo QT del ciclo cardiaco   n + 1 (QT<sub>n + 1</sub>) en funci&oacute;n de los intervalos TQ y   QT en el ciclo cardiaco anterior (TQ<sub>n</sub> y QT<sub>n</sub>). A esta   curva obtenida experimentalmente a nivel ECG se le   ajusta una curva de restituci&oacute;n param&eacute;trica extra&iacute;da   del modelo de PA, obteniendo cuatro par&aacute;metros   del modelo de PA. El resto de los par&aacute;metros del   modelo de PA se estiman por medio de la simulaci&oacute;n   de este mismo, utilizando como entrada un tren de   pulsos cuya frecuencia est&aacute; dada por la frecuencia   cardiaca del ECG del sujeto experimentado (ver <a href="#fig4">Fig.   4</a>). Finalmente, a partir del PA simulado, se miden el   APD y el DI para cada ciclo cardiaco y se comparan   las curvas de restituci&oacute;n celular obtenidas del modelo   con las ECG-RC3D obtenidas experimentalmente.   Igualmente se comparan la variaci&oacute;n del intervalo QT   obtenido experimentalmente a partir del ECG con la   del intervalo APD simulado del modelo.</p>       <p align="center"><a name="fig4"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig4.gif"></p>     <p><i><font size="3">2.1. El ejercicio isom&eacute;trico handgrip</font></i></p>     <p>A nivel ECG, tal como a nivel celular (ver Secci&oacute;n   1.1), es necesario un protocolo de registro que permita   generar din&aacute;micas de aceleraci&oacute;n y deceleraci&oacute;n   de la frecuencia cardiaca para obtener variaciones   importantes de los intervalos QT y TQ. Esto se logra   con el test isom&eacute;trico <i>handgrip</i> al cual es sometido el   sujeto examinado.</p>     <p>Este examen consiste en que el sujeto realice una   contracci&oacute;n isom&eacute;trica voluntaria con su mano contra una   resistencia ajustable por medio de resortes. Un ejercicio   isom&eacute;trico es un tipo de ejercicio durante el cual los   m&uacute;sculos no sufren cambio de longitud pero generan una   tensi&oacute;n mucho mayor que lo que se observa en estado de   reposo. Este ejercicio produce dos efectos esenciales para   este estudio:</p>   <ul type="disc">     <li>Conduce a un r&aacute;pido incremento de la frecuencia   cardiaca al inicio del esfuerzo (ver <a href="#fig5">Fig. 5</a>).</li>     ]]></body>
<body><![CDATA[<li>Asegura una variaci&oacute;n importante de los   intervalos QT y TQ del ECG.   Posee igualmente dos ventajas pr&aacute;cticas importantes:</li>     <li>Es un ejercicio de f&aacute;cil implementaci&oacute;n.</li>     <li>Provee una se&ntilde;al ECG de buena calidad ya que   posee muy bajo ruido de electromiograma debido a la poca   actividad muscular que el ejercicio requiere.</li>       </ul>       <p align="center"><a name="fig5"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig5.gif"></p>     <p>El test <i>handgrip</i> es de alguna forma similar al que se   realiza a nivel celular con el protocolo de estimulaci&oacute;n   presentado en &#91;<a href="#16">16</a>&#93;, donde se producen aceleraciones y   deceleraciones abruptas sostenidas de la frecuencia de   excitaci&oacute;n (en el caso del ECG de la frecuencia cardiaca).   El test <i>handgrip</i> es un ejercicio que desencadena casi   instant&aacute;neamente una respuesta cardiaca parasimp&aacute;tica   lo que resulta en r&aacute;pidos incrementos de la frecuencia   cardiaca y la presi&oacute;n arterial &#91;<a href="#36">36</a>&#93; como se puede observar   en la <a href="#fig5">Fig. 5</a>.</p>     <p><i><font size="3">2.2. Procedimiento de adquisici&oacute;n de datos</font></i></p>     <p>Los registros utilizados en el presente trabajo   corresponden a los mismos registros utilizados en &#91;<a href="#7">7</a>&#93;. A   continuaci&oacute;n se presentar&aacute; en detalle el procedimiento con   el cual se adquirieron dichos registros.</p>     <p>Se realizaron registros ECG de una derivaci&oacute;n (DII)   en 16 sujetos voluntarios adultos sanos a una frecuencia   de muestreo de 500 Hz, utilizando un dispositivo A/D   (PowerLab, ADInstrumentation, Australia). Los datos   fueron procesados utilizando los <i>software</i> cient&iacute;ficos   Matlab &#91;<a href="#37">37</a>&#93; y Scilab &#91;<a href="#38">38</a>&#93;.</p>     <p>Para el experimento cada sujeto se sienta   relajadamente en un sill&oacute;n y la mano que sostiene el   dispositivo <i>handgrip</i> permanece en una superficie   plana. Como entrenamiento el sujeto realiza con   el dispositivo <i>handgrip</i> unas pocas contracciones   voluntarias de 5 segundos de duraci&oacute;n cada una,   separadas de fases de un minuto de recuperaci&oacute;n   entre las dos contracciones. Este primer paso permite   asegurar que el esfuerzo requerido corresponde a   un esfuerzo entre 20% y 30% de una contracci&oacute;n   voluntaria m&aacute;xima. Una intensidad de esfuerzo inferior   podr&iacute;a no producir los efectos <i>handgrip</i> deseados y en   el caso de intensidades de esfuerzo muy altas ser&iacute;a muy   dif&iacute;cil mantener este esfuerzo durante 60 segundos.</p>     ]]></body>
<body><![CDATA[<p>Luego de la etapa de entrenamiento y de una etapa   de reposo de 10 minutos, el sujeto es sometido a cuatro ejercicios Handgrip de 60 segundos, separados de   intervalos de recuperaci&oacute;n de dos minutos.</p>     <p><i><font size="3">2.3. Obtenci&oacute;n de la curva de restituci&oacute;n en tres   dimensiones a partir del ECG</font></i></p>     <p>Con el fin de obtener una curva de restituci&oacute;n a nivel   ECG se requieren los siguientes pasos:</p>   <ul type="disc">     <li>Registro del ECG durante el test <i>handgrip</i>.</li>     <li>C&aacute;lculo autom&aacute;tico de los intervalos QT y   TQ del ECG.</li>       </ul>     <p>El primer paso ya fue explicado en la secci&oacute;n anterior   por lo que esta secci&oacute;n se dedicar&aacute; a presentar en detalle el   c&aacute;lculo del intervalo QT.</p>     <p>La <a href="#fig6">Fig. 6</a> muestra un diagrama de bloques que presenta   los pasos para segmentar autom&aacute;ticamente el ECG con el   fin de calcular los instantes de principio de complejo QRS   y fin de la onda T. Estos instantes son utilizados para el   c&aacute;lculo de los intervalos QT y TQ. En una primera etapa   la se&ntilde;al ECG es filtrada utilizando un filtro pasabanda con   frecuencias de corte &#91;0.05 100&#93; Hz con el fin de atenuar   ruidos de la deriva de l&iacute;nea de base y ruidos de alta   frecuencia. El filtro consiste en aplicar la Transformada   R&aacute;pida de Fourier (FFT) a la se&ntilde;al ECG para luego truncar   las componentes frecuenciales indeseables y finalmente   aplicar la FFT inversa.</p>       <p align="center"><a name="fig6"></a><a href="img/revistas/rinbi/v7n13/v7n13a04fig6.gif" target="_blank">Figura 6</a></p>     <p>En una segunda etapa se detecta autom&aacute;ticamente   el umbral de la onda R del ECG. Este instante sirve   como referencia para la b&uacute;squeda posterior de los   instantes de principio de complejo QRS y fin de la onda   T. Para la detecci&oacute;n del umbral de la onda R se utiliz&oacute; el   algoritmo presentado en &#91;<a href="#39">39</a>, <a href="#40">40</a>&#93;. Este algoritmo consiste   principalmente en el c&aacute;lculo de un indicador basado en la   amplitud y la curvatura de la se&ntilde;al ECG. Es bien sabido   que en general la onda R posee la amplitud y curvatura   m&aacute;s grande en una se&ntilde;al ECG, por lo cual este indicador   diferencia de manera bastante eficaz la onda R del resto de   las ondas del ECG.</p>     ]]></body>
<body><![CDATA[<p>Luego de una etapa de ventaneado que sirve a   delimitar groseramente cada uno de los instantes   a detectar, se procede a detectar el principio del   complejo QRS y el fin de la onda T. La detecci&oacute;n del   principio del complejo QRS se realiz&oacute; utilizando el   algoritmo presentado en &#91;<a href="#39">39</a>&#93;. Este algoritmo consiste   en el c&aacute;lculo de la envolvente del ECG con el fin   de desmodular el complejo QRS en una se&ntilde;al tipo   campana de Gauss, cuyo principio y fin coincide con el   principio y fin del complejo QRS.</p>     <p>La detecci&oacute;n del fin de la onda T es conocida por ser   una tarea bastante compleja, especialmente en se&ntilde;ales   ECG no estacionarias. El algoritmo propuesto en &#91;<a href="#41">41</a>&#93;   ha sido elegido para ser utilizado en este estudio debido   a su robustez frente al ruido y a las no estacionaridades   del ECG. Este algoritmo est&aacute; basado en el c&aacute;lculo de un   &aacute;rea que est&aacute; parcialmente delimitada por la onda T. La   consistencia de este algoritmo ha sido probada asumiendo   esencialmente la hip&oacute;tesis de concavidad de la onda T. La   confiabilidad que presenta este algoritmo es esencial para   el objetivo de este estudio.</p>     <p>Finalmente la ECG-RC3D se obtiene de la misma   forma que en &#91;<a href="#7">7</a>&#93;, pero esta vez agregando un eje m&aacute;s, esto   es, graficando el intervalo QT al ciclo cardiaco n+1 en   funci&oacute;n de los intervalos TQ y QT al ciclo cardiaco n.</p>     <p><i><font size="3">2.4. Modelo de Potencial de acci&oacute;n celular   y relaci&oacute;n de restituci&oacute;n anal&iacute;tica</font></i></p>     <p>Lo que se busca en este estudio es poner en relaci&oacute;n   din&aacute;micas ECG con din&aacute;micas celulares por medio de   un modelo de PA celular. Claramente el modelo debe ser   simple y de baja cantidad de par&aacute;metros para que &eacute;stos   puedan ser estimados a partir de una sola derivaci&oacute;n del   ECG. Por ende la relaci&oacute;n se debe focalizar en din&aacute;micas   espec&iacute;ficas que ocurren a nivel de una c&eacute;lula. Como se   present&oacute; en la Secci&oacute;n 1.1, la principal din&aacute;mica celular a   relacionar en el ECG es la din&aacute;mica de restituci&oacute;n celular,   por lo cual el modelo de PA utilizado debe ser capaz de   reproducir dicha din&aacute;mica.</p>     <p>En &#91;<a href="#7">7</a>&#93; se utiliz&oacute; el modelo de PA presentado en &#91;<a href="#20">20</a>&#93;   para relacionar nivel celular con nivel ECG en registros   realizados durante el test <i>handgrip</i>. Este modelo permiti&oacute;   extraer una curva de restituci&oacute;n celular anal&iacute;tica de dos   dimensiones, como la de la ecuaci&oacute;n (<a href="#for1">1</a>), la cual permite   ajustar una curva de restituci&oacute;n dos dimensiones, obtenida   a partir del ECG.</p>     <p>En el presente trabajo se realiz&oacute; un estudio similar al   realizado en &#91;<a href="#7">7</a>&#93; con la diferencia que se utilizan relaciones   de restituci&oacute;n de tres dimensiones como la de la ecuaci&oacute;n   (<a href="#2">2</a>). Para ello se utiliz&oacute; un modelo de PA celular del cual   es posible extraer una curva de restituci&oacute;n anal&iacute;tica en tres   dimensiones. El modelo de PA utilizado en este trabajo es   el modelo presentado en &#91;<a href="#19">19</a>&#93;, descrito por el sistema de   ecuaciones (<a href="#3">3</a>):</p>     <p align="center"><a name="for2"></a><img src="img/revistas/rinbi/v7n13/v7n13a04for2.gif"></p>     <p>Este modelo corresponde a un modelo de PA celular   a tres corrientes i&oacute;nicas, las cuales corresponden   indirectamente a las corrientes i&oacute;nicas de sodio <i>J<sub>Na</sub></i>, de   calcio <i>J<sub>Ca</sub></i> y de potasio <i>J<sub>K</sub></i> respectivamente. El modelo   posee tres variables de estado, una correspondiente al   potencial de acci&oacute;n <i>v</i>, y las otras dos correspondientes   a variables de puerta que regulan las entradas de iones   sodio (<i>f</i>) y calcio (<i>s</i>). Una simulaci&oacute;n de estas tres   variables de estado que involucra el modelo se puede   observar en la <a href="#fig7">Fig. 7</a>.</p>       <p align="center"><a name="fig7"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig7.gif"></p>     ]]></body>
<body><![CDATA[<p>La corriente i&oacute;nica de sodio corresponde a una   corriente de din&aacute;mica r&aacute;pida dependiente del potencial   <i>v</i>, de la variable de puerta <i>f</i> y de una constante de   tiempo &tau;<sub>f</sub> que representa la din&aacute;mica del sodio entrante   en la c&eacute;lula. La corriente i&oacute;nica de calcio corresponde a   una corriente de din&aacute;mica lenta dependiente igualmente   de <i>v</i>, de la variable de puerta <i>s</i> y de una constante de   tiempo &tau;<sub>s</sub> que representa la din&aacute;mica de iones calcio   entrando en la c&eacute;lula. La corriente i&oacute;nica de potasio no   est&aacute; regulada por una variable de puerta, solo depende   de <i>v</i> y de su constante de tiempo &tau;<sub>u</sub> que representa la   din&aacute;mica de iones potasio saliendo de la c&eacute;lula. Las   variaciones de las variables de puerta <i>f</i> y <i>s</i> dependen   de constantes de tiempo con las cuales se abren y   cierran las compuertas que dejan entrar las corrientes de sodio (&tau;<sub>Naopen</sub> y &tau;<sub>Naclose</sub>) y calcio (&tau;<sub>Caopen</sub> y &tau;<sub>Caclose</sub>)   respectivamente. La corriente de estimulaci&oacute;n Jstim   corresponde a una corriente externa que consiste en   un tren de pulsos de alrededor de 1 ms de duraci&oacute;n.   Para mayores detalles acerca del modelo se sugiere   consultar el trabajo presentado en &#91;<a href="#19">19</a>&#93;. En total el   modelo involucra siete par&aacute;metros correspondientes   todos a las constantes de tiempo que rigen las entradas   y salidas de iones de la c&eacute;lula.</p>     <p>Una de las ventajas de este modelo es que a partir   de &eacute;ste es posible extraer una f&oacute;rmula param&eacute;trica   expl&iacute;cita para una curva de restituci&oacute;n celular en tres   dimensiones. Esta ventaja es fundamental para la   estimaci&oacute;n de la mayor&iacute;a de los par&aacute;metros del modelo   de PA celular a partir del ECG. Esta f&oacute;rmula es de   la forma dada en la ecuaci&oacute;n (<a href="#for1">2</a>), donde la funci&oacute;n   g consiste en una funci&oacute;n tipo exponencial en tres   dimensiones (ver <a href="#fig8">Fig. 8</a>) cuyo modelo param&eacute;trico se   muestra en (<a href="#for3">4</a>). Se sugiere consultar &#91;<a href="#19">19</a>&#93; para mayores   detalles acerca de la extracci&oacute;n de (<a href="#for3">4</a>) a partir de (<a href="#for2">3</a>).</p>       <p align="center"><a name="for3"></a><img src="img/revistas/rinbi/v7n13/v7n13a04for3.gif"></p>     <p align="center"><a name="fig8"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig8.gif"></p>     <p>donde,</p>     <p align="center"><a name="for4"></a><img src="img/revistas/rinbi/v7n13/v7n13a04for4.gif"></p>       <p><i>V<sub>crit</sub></i> y <i>V<sub>sig</sub></i> corresponden simplemente a umbrales de   voltaje a la cual la c&eacute;lula responde por un potencial de acci&oacute;n.</p>       <p>De acuerdo a lo anterior el modelo de PA de (<a href="#for2">3</a>)   involucra siete par&aacute;metros, por lo cual el vector de   par&aacute;metros a estimar en el modelo de PA es:</p>       <p align="center"><i>&theta;<sub>PA</sub></i>=&#91;&tau;<sub>f</sub> ,&tau;<sub>s</sub>,&tau;<sub>u</sub>,&tau;<sub>Naopen</sub>,&tau;<sub>Naclose</sub>,&tau;<sub>Caopen</sub>,&tau;<sub>Caclose</sub>&#93;</p>       <p>Mientras que el modelo anal&iacute;tico de curva de   restituci&oacute;n celular de (<a href="#fig3">4</a>) involucra cuatro par&aacute;metros. Por   lo cual el vector de par&aacute;metros que es posible estimar a   partir del modelo de curva de restituci&oacute;n celular es:</p>       ]]></body>
<body><![CDATA[<p align="center"><i>&theta;<sub>CR</sub></i>=&#91;&tau;<sub>s</sub>,&tau;<sub>u</sub>,&tau;<sub>Caopen</sub>,&tau;<sub>Caclose</sub>&#93;</p>       <p>Este vector de par&aacute;metros es estimado ajustando el   modelo param&eacute;trico de curva de restituci&oacute;n celular de (<a href="#fig3">4</a>)   a la curva de restituci&oacute;n experimental obtenida a partir   del ECG, (ECG-RC3D) utilizando el <i>m&eacute;todo de m&iacute;nimos   cuadrados no lineal</i>.</p>       <p>Finalmente los tres par&aacute;metros restantes de (<a href="#fig2">3</a>), esto   es, &#91;&tau;<sub>f</sub> ,&tau;<sub>Naopen</sub> ,&tau;<sub>Naclose</sub>&#93; son estimados minimizando el error   cuadr&aacute;tico promedio entre el APD simulado del modelo de   PA y el intervalo QT obtenido experimentalmente del ECG   (para mayores detalles ver &#91;<a href="#7">7</a>&#93;).</p>       <p>&nbsp;</p>       <p><b><font size="3">III. RESULTADOS</font></b> </p>       <p>En esta secci&oacute;n se presentan los principales resultados   obtenidos en este trabajo. Estos pueden ser divididos   en cuatro partes: variaci&oacute;n de los intervalos TQ y QT   durante el test del <i>handgrip</i>, obtenci&oacute;n de la ECG-RC3D   experimentales, ajuste de esta curva basada en el ECG   por medio de la curva de restituci&oacute;n anal&iacute;tica de (<a href="#for3">4</a>), y   simulaci&oacute;n del modelo de PA a tres corrientes i&oacute;nicas   utilizando los par&aacute;metros estimados a partir del ECG. En   esta &uacute;ltima parte se presentar&aacute;n las curvas de restituci&oacute;n   simuladas y experimentales as&iacute; como tambi&eacute;n las   variaciones de los intervalos APD a nivel celular y QT a   nivel ECG.</p>       <p>Para poder obtener la ECG-RC3D, tal como a nivel   celular, es necesario registrar el ECG bajo un protocolo   que permita una variaci&oacute;n suficiente de los intervalos   involucrados en la relaci&oacute;n de restituci&oacute;n. Estas   variaciones se logran mediante el test del <i>handgrip</i>, cuya   utilizaci&oacute;n permiti&oacute; obtener curvas de restituci&oacute;n en dos   dimensiones en &#91;<a href="#7">7</a>&#93;. La <a href="#fig9">Fig. 9</a> muestra las variaciones   del intervalo QT y TQ del ECG durante una contracci&oacute;n   voluntaria realizada en el test <i>handgrip</i> &#91;<a href="#7">7</a>&#93;. Se observa   que al ciclo cardiaco correspondiente al inicio del   esfuerzo (Hon), tanto el intervalo TQ como el intervalo   QT comienzan a disminuir, pero sin la misma din&aacute;mica.   Por un lado el intervalo TQ presenta una disminuci&oacute;n   r&aacute;pida al comienzo del esfuerzo para luego estabilizarse   lentamente en un valor casi estacionario. La recuperaci&oacute;n   de este intervalo es r&aacute;pida luego de que se pone fin a   la contracci&oacute;n (Hoff). Por otro lado el intervalo QT   disminuye linealmente durante el proceso de contracci&oacute;n   sin alcanzar un valor estacionario, para luego, al t&eacute;rmino   de la contracci&oacute;n, recuperarse linealmente con una   pendiente muy similar a la producida por la fase de   contracci&oacute;n. Estas din&aacute;micas muestran de qu&eacute; forma   tanto el intervalo QT como el TQ se van ajustando a los   requerimientos generados durante el primer minuto del test <i>handgrip</i>, de una manera similar a lo que sucede a nivel   celular con el APD y el DI.</p>     <p align="center"><a name="fig9"></a><img src="img/revistas/rinbi/v7n13/v7n13a04fig9.gif"></p>       <p>La <a href="#fig10">Fig. 10</a> muestra las ECG-RC3D obtenidas durante   la fase de contracci&oacute;n en el test <i>handgrip</i> para cuatro   sujetos diferentes. Se puede observar claramente la forma   exponencial en tres dimensiones que rige la relaci&oacute;n entre   los intervalos QT<sub>n + 1</sub>, TQ<sub>n</sub> y QT<sub>n</sub> durante el test <i>handgrip</i>.   Esta relaci&oacute;n es similar a la encontrada a nivel celular   entre el APD<sub>n + 1</sub>, DI<sub>n</sub> y APD<sub>n</sub> &#91;<a href="#28">28</a>-<a href="#30">30</a>&#93;. A estas curvas de   restituci&oacute;n se les ajust&oacute; el modelo anal&iacute;tico de curva de   restituci&oacute;n celular de (<a href="#for3">4</a>) con el fin de estimar las cuatro   contantes de tiempo de este modelo como se puede   observar en la <a href="#fig11">Fig. 11</a>.</p>       <p align="center"><a name="fig10"></a><a href="img/revistas/rinbi/v7n13/v7n13a04fig10.gif" target="_blank">Figura 10</a></p>       ]]></body>
<body><![CDATA[<p align="center"><a name="fig11"></a><a href="img/revistas/rinbi/v7n13/v7n13a04fig11.gif" target="_blank">Figura 11</a></p>       <p>Las <a href="#fig12">figuras 12</a> y <a href="#fig13">13</a> comparan los resultados de las   simulaciones del modelo de PA con los par&aacute;metros   estimados a partir del ECG. La <a href="#fig12">Fig. 12</a> muestra una   comparaci&oacute;n entre la ECG-RC3D (c&iacute;rculos negros) y   la curva de restituci&oacute;n resultante de la simulaci&oacute;n del   modelo de PA (c&iacute;rculos rojos) con todos los par&aacute;metros   estimados. Se puede observar que tanto la ECG-RC3D   experimental como la curva de restituci&oacute;n simulada   tienen forma exponencial y sus puntos se distribuyen en el   espacio de tres dimensiones en coordenadas similares. M&aacute;s   a&uacute;n, si se compara la variaci&oacute;n del intervalo QT obtenida   experimentalmente a partir del ECG registrado durante   el <i>handgrip</i> y la variaci&oacute;n del APD simulado del modelo   de PA (ver <a href="#fig13">Fig. 13</a>) se puede ver que &eacute;sta &uacute;ltima sigue de   manera satisfactoria el QT experimental. Esto quiere decir   que, desde un punto de vista de din&aacute;micas de restituci&oacute;n   en tres dimensiones, el modelo param&eacute;trico de PA es   identificable a partir de las observaciones correspondientes   al ECG trav&eacute;s del modelo de curva de restituci&oacute;n.</p>       <p align="center"><a name="fig12"></a><a href="img/revistas/rinbi/v7n13/v7n13a04fig12.gif" target="_blank">Figura 12</a></p>       <p align="center"><a name="fig13"></a><a href="img/revistas/rinbi/v7n13/v7n13a04fig13.gif" target="_blank">Figura 13</a></p>       <p>&nbsp;</p>       <p><b><font size="3">IV. DISCUSI&Oacute;N Y CONCLUSI&Oacute;N</font></b> </p>       <p>En este trabajo se present&oacute; un estudio que ten&iacute;a como   finalidad relacionar din&aacute;micas el&eacute;ctricas cardiacas que   ocurren a dos niveles diferentes. Por un lado la actividad   el&eacute;ctrica celular cardiaca a un nivel microsc&oacute;pico y por   otro lado los potenciales registrados a nivel macrosc&oacute;pico   en la superficie del cuerpo con el ECG. La idea principal   fue utilizar una din&aacute;mica espec&iacute;fica que ocurre a nivel   celular, que permitiera ser modelada en funci&oacute;n de   un modelo param&eacute;trico simple, con el fin de poder   relacionarlas a solo una derivaci&oacute;n del ECG. Esto se hizo   por medio de la identificaci&oacute;n de un modelo param&eacute;trico   de PA celular cuyos par&aacute;metros pudieran ser estimados a   partir de una se&ntilde;al ECG.</p>       <p>Los resultados experimentales obtenidos demostraron   que la ECG-RC3D que relaciona los intervalos QT   y TQ en una sola derivaci&oacute;n del ECG es similar a la   extensamente estudiada curva de restituci&oacute;n celular   que relaciona el APD con el DI de distintos potenciales   de acci&oacute;n. Esto permiti&oacute; relacionar din&aacute;micas ECG a   din&aacute;micas celulares por medio de un modelo de potencial   de acci&oacute;n celular a tres corrientes i&oacute;nicas que pudo   ser completamente identificado gracias la similitud de   din&aacute;micas de restituci&oacute;n que ocurren a nivel celular y   a nivel ECG. Prueba de esta identificaci&oacute;n es que los   par&aacute;metros estimados del modelo de PA a partir del   ECG permitieron simular este modelo resultando en   similitudes satisfactorias entre las din&aacute;micas obtenidas   experimentalmente con un sujeto dado y din&aacute;micas   generadas de un modelo matem&aacute;tico cuyos par&aacute;metros son   propios del sujeto experimentado.</p>       <p>Si bien es cierto los registros ECG utilizados en este   trabajo son exactamente los mismos que los utilizados   en &#91;<a href="#7">7</a>&#93;, donde se obtuvieron curvas de restituci&oacute;n en   dos dimensiones, el estudio se focaliz&oacute; en relaciones   de restituciones en tres dimensiones con el fin de   identificar un modelo de PA de mayor complejidad que   en &#91;<a href="#7">7</a>&#93;. Esto nos permite identificar el proceso en base a   un modelo que posee m&aacute;s grados de libertad que en &#91;<a href="#7">7</a>&#93;   y por ende un mayor nivel de detalle en las din&aacute;micas   el&eacute;ctricas celulares. M&aacute;s a&uacute;n, el nuevo modelo utilizado   &#91;<a href="#19">19</a>&#93; involucra variables que poseen una significancia   fisiol&oacute;gica mayor que el modelo utilizado en &#91;<a href="#7">7</a>&#93;, ya que   involucra tres corrientes i&oacute;nicas correspondientes al Na+,   Ca+ y K+ (el modelo presentado en &#91;<a href="#20">20</a>&#93; y utilizado en   &#91;<a href="#7">7</a>&#93; involucra &uacute;nicamente corrientes equivalentes de   entrada y salida).</p>       <p>Con esto se abren diversas perspectivas que podr&iacute;an   ser importantes en electrocardiograf&iacute;a en un futuro   cercano, sobre todo considerando que se utilizan registros   ECG est&aacute;ndar. Una primera posible aplicaci&oacute;n es adaptar   los estudios ya hechos a nivel de curva de restituci&oacute;n   celular a la curva de restituci&oacute;n basada en el ECG. Como   se vio en la Secci&oacute;n 1.1, estudios realizados a nivel celular   han mostrado que la forma de la curva de restituci&oacute;n   celular, particularmente su pendiente, est&aacute; directamente   relacionada a la ocurrencia de alternancias. Esto &uacute;ltimo   nos lleva a una segunda aplicaci&oacute;n posible que tiene que   ver con la relaci&oacute;n que puede existir entre las ya conocidas   alternancias de la onda T &#91;<a href="#42">42</a>, <a href="#43">43</a>&#93; y las alternancias del   APD, las cuales podr&iacute;an tener una explicaci&oacute;n por medio   de la relaci&oacute;n de restituci&oacute;n.</p>       ]]></body>
<body><![CDATA[<p>&nbsp;</p>       <p><b><font size="3">AGRADECIMIENTOS</font></b></p>       <p>Se agradece enormemente el apoyo de la Direcci&oacute;n   de Investigaci&oacute;n y Desarrollo (DID) de la Universidad   Austral de Chile por medio del financiamiento del   proyecto s-2009-28. Se agradece igualmente a V&iacute;ctor   Alcafuz, Juan Pablo Arias y Alejandro Bert&iacute;n que con sus   tesis de pregrado aportaron significativos aportes a los   avances de este trabajo.</p>       <p>&nbsp;</p>       <p><b><font size="3">REFERENCIAS</font></b></p>       <!-- ref --><p>&#91;<a name="1">1</a>&#93;. Malmivuo J., Plonsey R. Bioelectromagnetism: Principles   and Aplication of Bioelectric and Biomagnetic Fields. Oxford   University Press, 1995. Cap&iacute;tulo 6, 165-177.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S1909-9762201300010000400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="2">2</a>&#93;. S&ouml;rnmo L., Laguna P. Bioelectrical signal processing in cardiac   and neurological applications. <i>Elsevier</i>, 2005. Cap&iacute;tulo 6,   411-452.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S1909-9762201300010000400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="3">3</a>&#93;. Arnold L., Page J., Attwell D., Cannell M., Eisner D. The   dependence on heart rate of the human ventricular action potential   duration. <i>Cardiovascular research</i>, 313, 547-551, 1981.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S1909-9762201300010000400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="4">4</a>&#93;. Attwell D., Cohen I., Eisner D. The effects of heart rate on the   action potential of guinea-pig and human ventricular muscle. <i>The   Journal of Physiology</i>, 16, 439-461, 1982.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S1909-9762201300010000400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="5">5</a>&#93;. Fossa A., Wisialowski T., Crimin K. QT prolongation modi&#64257;es   dynamic restitution and hysteresis of the beat-to-beat QTTQ   interval relationship during normal sinus rhythm under   varying states of repolarization. <i>Journal of Pharmacology and   Experimental Therapeutics</i>, 316(2), 498-506, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S1909-9762201300010000400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="6">6</a>&#93;. Fossa A., Wisialowski T., Crimin K., Wolfgang E., Couderc   J.P., Hinterseer M., Kaab S., Zareba W., Badilini F., Sarapa   N. Analyses of dynamic Beat-to-Beat QT-TQ interval (ECG   restitution) changes in humans under normal sinus rhythm and   prior to an event of Torsades de Pointes during QT prolongation   caused by Sotalol. <i>Annals of noninvasive electrocardiology</i>, 12(4),   338-348, 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S1909-9762201300010000400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="7">7</a>&#93;. Illanes Manriquez A., Zhang Q., Medigue C., Papelier Y., Sorine   M. Electrocardiogram-based restitution curve. <i>Proceedings of the   Computers in Cardiology</i>, Valencia, Spain, 33, 493-496, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S1909-9762201300010000400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="8">8</a>&#93;. Panfilov, A. V. (ed.) <i>et al</i>. Forward and inverse problems in   electrocardiography. Computational biology of the heart.   Workshop on Whole Heart Modeling, 11th-13th February 1994,   Utrecht, the Netherlands. Chichester: Wiley. 295-343, 1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S1909-9762201300010000400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="9">9</a>&#93;. MacLeod R., Brooks D. Recent progress in inverse problems in   electrocardiology. <i>IEEE Engineering in Medicine and Biology</i>,   17(1), 73-83, January/February 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S1909-9762201300010000400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="10">10</a>&#93;. Gulrajani R. The forward and inverse problems of   electrocardiography: Gaining a better qualitative and   quantitative understanding of the heart's electrical activity.   <i>IEEE Engineering in Medicine and Biology</i>, 17(5), 84-122,   September/October 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S1909-9762201300010000400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="11">11</a>&#93;. Armoundas A., FeldmanA., Mukkamala R., Cohen R. A single   equivalent moving dipole model: An efficient approach for   localizing sites of origin of ventricular electrical activation.   <i>Annals of Biomedical Engineering</i>, 31, 564-576, 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S1909-9762201300010000400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="12">12</a>&#93;. Ghodrati A., Brooks D., Tadmor G., MacLeod R. Wavefrontbased   models for inverse electrocardiography. <i>IEEE Transaction   on Biomedical Engineering</i>, 53(9), 1821-1831, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S1909-9762201300010000400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="13">13</a>&#93;. Nielsen B., Cai X., Lysaker M. On the possibility for   computing the transmembrane potential in the heart with a one   shot method: An inverse problem. Mathematical Biosciences,   210, 523-553, 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S1909-9762201300010000400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="14">14</a>&#93;. Franz M., Schaefer J., Schottler M., Seed W., Noble M. Electrical   and mechanical restitution of the human heart at different rates of   stimulation. <i>Circulation</i>, 53, 815-822, 1983.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S1909-9762201300010000400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="15">15</a>&#93;. Elharrar V., Surawicz B. Cycle length effect on restitution of   action potential duration in dog cardiac &#64257;bers. <i>American Journal   of Physiologie</i>, 244, H782-H792, 1983.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S1909-9762201300010000400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="16">16</a>&#93;. Franz M., Swerdlow C., Liem B., Schaefer J. Cycle length   dependence of human action potential duration in vivo. <i>The   American Society for Clinical Investigation</i>, 82, 972-979, 1988.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S1909-9762201300010000400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="17">17</a>&#93;. Koller M., Riccio M., Gilmour R. Dynamic restitution of action   potential duration during electrical alternans ans ventricular   &#64257;brillation. <i>American Journal of Physiology</i>, 275(2), H1635-   H1642, 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S1909-9762201300010000400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="18">18</a>&#93;. Koller M., Maier S., Gelzer A., Bauer W., Meesmann M.,   Gilmour R. Altered dynamics of action potential restitution and   alternans in humans with structural heart disease. <i>Circulation</i>,   112, 1542-1548, 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S1909-9762201300010000400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="19">19</a>&#93;. Tolkacheva E., Schaeffer D., Gauthier D., Mitchell C. Analysis   of the Fenton-Karma model through an approximation by a onedimensional   map. <i>Chaos</i>, 12(4), 1034-1042, 2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S1909-9762201300010000400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="20">20</a>&#93;. Mitchell C., Schaeffer D. A two-current model for de dynamics   of cardiac membrane. <i>Bulletin of Mathematical Biology</i>, 65,   767-793, 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S1909-9762201300010000400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="21">21</a>&#93;. Jordan P., Christini D. Determining the effects of memory   and action potential duration alternans on cardiac restitution   using a constant-memory restitution protocol. <i>Physiological   measurements</i>, 25, 1013-1024, 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S1909-9762201300010000400021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="22">22</a>&#93;. Nolasco J., Dahlen R. A graphic method for the study of   alternation in cardiac action potentials. <i>Journal of Applied   Physiology</i>, 25, 191-196, 1968.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000160&pid=S1909-9762201300010000400022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="23">23</a>&#93;. Karma A. Electrical alternans and spiral wave breakup in cardiac   tissue. <i>Chaos</i>, 4(3), 461-472, 1994.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000162&pid=S1909-9762201300010000400023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="24">24</a>&#93;. Watanabe M., Otani N., Gilmour R. Biphasic restitution   of action potential duration and complex dynamics in   ventricular myocardium. <i>Circulation Research</i>, 76, 915-921,   1995.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000164&pid=S1909-9762201300010000400024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="25">25</a>&#93;. Watanabe M., Fenton F., Evans S., Hastings H., Karma   A. Mechanisms for discordant alternans. <i>Journal of   Cardiovascular Electrophysiology</i>, 12(2), 196-206, 2001.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000166&pid=S1909-9762201300010000400025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="26">26</a>&#93;. Franz M. The electrical restitution curve revisited: Steep   or &#64258;at slope - which is better. <i>Journal of Cardiovascular   Electrophysiology</i>, 14(10), S140-S147, October 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000168&pid=S1909-9762201300010000400026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="27">27</a>&#93;. Cain J., Tolkacheva E., Shaeffer D., Gauthier D. Rate-dependent   propagation of cardiac action potentials in a one-dimensional   fiber. <i>Physical Review</i>, 70, 061906, 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000170&pid=S1909-9762201300010000400027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="28">28</a>&#93;. Otani N., Gilmour R. Memory models for the electrical properties   of local cardiac systems. <i>J. Theor. Biol</i>., 187, 409-436, 1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000172&pid=S1909-9762201300010000400028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="29">29</a>&#93;. Gilmour R., Otani N., Watanabe M. Memory and complex   dynamics in cardiac Purkinje fibers. <i>American Journal of   Physiology</i>, 272, H1826-H1832, 1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000174&pid=S1909-9762201300010000400029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="30">30</a>&#93;. Tolkacheva E., Schaeffer D., Gauthier D., Krassowska W.   Condition for alternans and stability of the 1:1 response pattern in   a "memory" model of paced cardiac dynamics. <i>Physical Review   E</i>, 67, 031904, 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000176&pid=S1909-9762201300010000400030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="31">31</a>&#93;. Illanes A., S&eacute;randour G. Modelo param&eacute;trico de actividad   el&eacute;ctrica celular cardiaca estimado mediante electrocardiograma.   Terceras Jornadas de Ingenier&iacute;a Biom&eacute;dica JCIB 2012, Vi&ntilde;a del   Mar, Chile, 2012.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000178&pid=S1909-9762201300010000400031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="32">32</a>&#93;. Boyett M., Jewell B. A study of the factors responsible for   rate-dependent shortening of the action potential in mammalian   ventricular muscle. <i>Journal of Physiology</i>, 285, 359-380, 1978.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000180&pid=S1909-9762201300010000400032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="33">33</a>&#93;. Guevara M., Ward G., Shrier A., Glass L. Electrical alternans   and period doubling bifurcations. <i>Computers in Cardiology</i>,   167-170, 1984.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000182&pid=S1909-9762201300010000400033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="34">34</a>&#93;. Abildskov J. The sequence of normal recovery of excitability in   the dog heart. <i>Circulation research</i>, 52, 442-446, 1975.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000184&pid=S1909-9762201300010000400034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="35">35</a>&#93;. Watanabe T., Rautaharju P., McDonald T. Ventricular action   potentials, ventricular extracellular potentials, and ECG of   guinea-pig. <i>Circulation Research</i>, 57, 362-373, 1985.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000186&pid=S1909-9762201300010000400035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="36">36</a>&#93;. M&eacute;digue C., Papelier Y., Bise S., Sorine M. Short term control   of the cardiovascular system: Assessment with the isometric <i>handgrip</i> exercise. INRIA, Tech. Rep., 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000188&pid=S1909-9762201300010000400036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="37">37</a>&#93;. Matlab. The Mathwork Inc., Natick, Massachusetts. <a href="http://www.mathworks.com/" target="_blank">http://www.mathworks.com/</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000190&pid=S1909-9762201300010000400037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="38">38</a>&#93;. Scilab: The open source platform for numerical computation,   <a href="http://www.scilab.org/" target="_blank">http://www.scilab.org/</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000192&pid=S1909-9762201300010000400038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="39">39</a>&#93;. Illanes Manriquez A., Zhang Q. An algorithm for QRS onset   and offset detection in single lead electrocardiogram records.   Proceedings of the 29th Annual International Conference of the   IEEE EMBS, Lyon, France, 29, 541-544, 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000194&pid=S1909-9762201300010000400039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="40">40</a>&#93;. Chac&oacute;n F., Illanes-Manriquez A. Evaluaci&oacute;n de un algoritmo   simple de detecci&oacute;n de onda R con bases de datos est&aacute;ndares.   <i>Segundas Jornadas Chilenas de Ingenier&iacute;a Biom&eacute;dica</i>, Vi&ntilde;a del   Mar, Chile, 2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000196&pid=S1909-9762201300010000400040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="41">41</a>&#93;. Zhang Q., Illanes Manriquez A., M&eacute;digue C., Papelier Y., Sorine   M. An algorithm for robust and efficient location of T-wave   ends in electrocardiograms. <i>IEEE Transaction on Biomedical   Engineering</i>, 53(12), 2544-2552, 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000198&pid=S1909-9762201300010000400041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="42">42</a>&#93;. Chow T., Saghir S., Bartone C., Goebel M., Schneider J., Booth   T., Chan PS. Usefulness of microvolt T-wave alternans on   predicting outcome in patients with ischemic cardiomyopathy   with and without defibrillators. <i>Am J Cardiol</i>, 100(4), 598-604,   2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000200&pid=S1909-9762201300010000400042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&#91;<a name="43">43</a>&#93;. Bloomfield D., Bigger J., Steinman R., Namerow P., Parides   M., Curtis A., Kaufman E., Davidenko J., Shinn T., Fontaine   J. Microvolt T-wave alternans and the risk of death or sustained   ventricular arrhythmias in patients with left ventricular   dysfunction. <i>J Am Coll Cardiol</i>, 47(2), 456-63, 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000202&pid=S1909-9762201300010000400043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>   </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Malmivuo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Plonsey]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Bioelectromagnetism: Principles and Aplication of Bioelectric and Biomagnetic Fields]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sörnmo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Laguna]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bioelectrical signal processing in cardiac and neurological applications]]></article-title>
<source><![CDATA[Elsevier]]></source>
<year>2005</year>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arnold]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Page]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Attwell]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Cannell]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Eisner]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The dependence on heart rate of the human ventricular action potential duration]]></article-title>
<source><![CDATA[Cardiovascular research]]></source>
<year>1981</year>
<volume>313</volume>
<page-range>547-551</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Attwell]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Eisner]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effects of heart rate on the action potential of guinea-pig and human ventricular muscle]]></article-title>
<source><![CDATA[The Journal of Physiology]]></source>
<year>1982</year>
<volume>16</volume>
<page-range>439-461</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fossa]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wisialowski]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Crimin]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[QT prolongation modi&#64257;es dynamic restitution and hysteresis of the beat-to-beat QTTQ interval relationship during normal sinus rhythm under varying states of repolarization]]></article-title>
<source><![CDATA[Journal of Pharmacology and Experimental Therapeutics]]></source>
<year>2006</year>
<volume>316</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>498-506</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fossa]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wisialowski]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Crimin]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Wolfgang]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Couderc]]></surname>
<given-names><![CDATA[J.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Hinterseer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kaab]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Zareba]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Badilini]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Sarapa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analyses of dynamic Beat-to-Beat QT-TQ interval (ECG restitution) changes in humans under normal sinus rhythm and prior to an event of Torsades de Pointes during QT prolongation caused by Sotalol]]></article-title>
<source><![CDATA[Annals of noninvasive electrocardiology]]></source>
<year>2007</year>
<volume>12</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>338-348</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Illanes Manriquez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Medigue]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Papelier]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Sorine]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocardiogram-based restitution curve]]></article-title>
<source><![CDATA[Proceedings of the Computers in Cardiology]]></source>
<year>2006</year>
<volume>Valencia</volume><volume>33</volume>
<page-range>493-496</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panfilov]]></surname>
<given-names><![CDATA[A. V.]]></given-names>
</name>
</person-group>
<source><![CDATA[Forward and inverse problems in electrocardiography: Computational biology of the heart]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MacLeod]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Brooks]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recent progress in inverse problems in electrocardiology]]></article-title>
<source><![CDATA[IEEE Engineering in Medicine and Biology]]></source>
<year>Janu</year>
<month>ar</month>
<day>y/</day>
<volume>17</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>73-83</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gulrajani]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The forward and inverse problems of electrocardiography: Gaining a better qualitative and quantitative understanding of the heart's electrical activity]]></article-title>
<source><![CDATA[IEEE Engineering in Medicine and Biology]]></source>
<year>Sept</year>
<month>em</month>
<day>be</day>
<volume>17</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>84-122</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Armoundas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Feldman]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mukkamala]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A single equivalent moving dipole model: An efficient approach for localizing sites of origin of ventricular electrical activation]]></article-title>
<source><![CDATA[Annals of Biomedical Engineering]]></source>
<year>2003</year>
<volume>31</volume>
<page-range>564-576</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghodrati]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brooks]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Tadmor]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[MacLeod]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wavefrontbased models for inverse electrocardiography]]></article-title>
<source><![CDATA[IEEE Transaction on Biomedical Engineering]]></source>
<year>2006</year>
<volume>53</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1821-1831</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nielsen]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Cai]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Lysaker]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the possibility for computing the transmembrane potential in the heart with a one shot method: An inverse problem]]></article-title>
<source><![CDATA[Mathematical Biosciences]]></source>
<year>2007</year>
<volume>210</volume>
<page-range>523-553</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schaefer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Schottler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Seed]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Noble]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical and mechanical restitution of the human heart at different rates of stimulation]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1983</year>
<volume>53</volume>
<page-range>815-822</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elharrar]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Surawicz]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cycle length effect on restitution of action potential duration in dog cardiac &#64257;bers]]></article-title>
<source><![CDATA[American Journal of Physiologie]]></source>
<year>1983</year>
<volume>244</volume>
<page-range>H782-H792</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Swerdlow]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Liem]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Schaefer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cycle length dependence of human action potential duration in vivo]]></article-title>
<source><![CDATA[The American Society for Clinical Investigation]]></source>
<year>1988</year>
<volume>82</volume>
<page-range>972-979</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koller]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Riccio]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gilmour]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dynamic restitution of action potential duration during electrical alternans ans ventricular &#64257;brillation]]></article-title>
<source><![CDATA[American Journal of Physiology]]></source>
<year>1998</year>
<volume>275</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>H1635- H1642</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koller]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Maier]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Gelzer]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bauer]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Meesmann]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gilmour]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Altered dynamics of action potential restitution and alternans in humans with structural heart disease]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2005</year>
<volume>112</volume>
<page-range>1542-1548</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tolkacheva]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Schaeffer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gauthier]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mitchell]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of the Fenton-Karma model through an approximation by a onedimensional map]]></article-title>
<source><![CDATA[Chaos]]></source>
<year>2002</year>
<volume>12</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1034-1042</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mitchell]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Schaeffer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A two-current model for de dynamics of cardiac membrane]]></article-title>
<source><![CDATA[Bulletin of Mathematical Biology]]></source>
<year>2003</year>
<volume>65</volume>
<page-range>767-793</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jordan]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Christini]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determining the effects of memory and action potential duration alternans on cardiac restitution using a constant-memory restitution protocol]]></article-title>
<source><![CDATA[Physiological measurements]]></source>
<year>2004</year>
<volume>25</volume>
<page-range>1013-1024</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nolasco]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dahlen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A graphic method for the study of alternation in cardiac action potentials]]></article-title>
<source><![CDATA[Journal of Applied Physiology]]></source>
<year>1968</year>
<volume>25</volume>
<page-range>191-196</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karma]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical alternans and spiral wave breakup in cardiac tissue]]></article-title>
<source><![CDATA[Chaos]]></source>
<year>1994</year>
<volume>4</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>461-472</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Otani]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Gilmour]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biphasic restitution of action potential duration and complex dynamics in ventricular myocardium]]></article-title>
<source><![CDATA[Circulation Research]]></source>
<year>1995</year>
<volume>76</volume>
<page-range>915-921</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fenton]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Evans]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hastings]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Karma]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanisms for discordant alternans]]></article-title>
<source><![CDATA[Journal of Cardiovascular Electrophysiology]]></source>
<year>2001</year>
<volume>12</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>196-206</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The electrical restitution curve revisited: Steep or &#64258;at slope - which is better]]></article-title>
<source><![CDATA[Journal of Cardiovascular Electrophysiology]]></source>
<year>Octo</year>
<month>be</month>
<day>r </day>
<volume>14</volume>
<numero>10^sS140-S147</numero>
<issue>10^sS140-S147</issue>
<supplement>S140-S147</supplement>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cain]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tolkacheva]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Shaeffer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gauthier]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rate-dependent propagation of cardiac action potentials in a one-dimensional fiber]]></article-title>
<source><![CDATA[Physical Review]]></source>
<year>2004</year>
<volume>70</volume>
<page-range>061906</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Otani]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Gilmour]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Memory models for the electrical properties of local cardiac systems]]></article-title>
<source><![CDATA[J. Theor. Biol]]></source>
<year>1997</year>
<volume>187</volume>
<page-range>409-436</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gilmour]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Otani]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Memory and complex dynamics in cardiac Purkinje fibers]]></article-title>
<source><![CDATA[American Journal of Physiology]]></source>
<year>1997</year>
<volume>272</volume>
<page-range>H1826-H1832</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tolkacheva]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Schaeffer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gauthier]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Krassowska]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Condition for alternans and stability of the 1:1 response pattern in a "memory" model of paced cardiac dynamics]]></article-title>
<source><![CDATA[Physical Review E]]></source>
<year>2003</year>
<volume>67</volume>
<page-range>031904</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Illanes]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sérandour]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Modelo paramétrico de actividad eléctrica celular cardiaca estimado mediante electrocardiograma]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[Terceras Jornadas de Ingeniería Biomédica JCIB 2012]]></conf-name>
<conf-date>2012</conf-date>
<conf-loc>Viña del Mar </conf-loc>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boyett]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jewell]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A study of the factors responsible for rate-dependent shortening of the action potential in mammalian ventricular muscle]]></article-title>
<source><![CDATA[Journal of Physiology]]></source>
<year>1978</year>
<volume>285</volume>
<page-range>359-380</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guevara]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Shrier]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Glass]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical alternans and period doubling bifurcations]]></article-title>
<source><![CDATA[Computers in Cardiology]]></source>
<year>1984</year>
<page-range>167-170</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abildskov]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The sequence of normal recovery of excitability in the dog heart]]></article-title>
<source><![CDATA[Circulation research]]></source>
<year>1975</year>
<volume>52</volume>
<page-range>442-446</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Rautaharju]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[McDonald]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ventricular action potentials, ventricular extracellular potentials, and ECG of guinea-pig]]></article-title>
<source><![CDATA[Circulation Research]]></source>
<year>1985</year>
<volume>57</volume>
<page-range>362-373</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Médigue]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Papelier]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Bise]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sorine]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Short term control of the cardiovascular system: Assessment with the isometric handgrip exercise]]></article-title>
<source><![CDATA[INRIA, Tech. Rep.]]></source>
<year>2004</year>
</nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="">
<collab>Matlab</collab>
<source><![CDATA[The Mathwork Inc]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="">
<collab>Scilab</collab>
<source><![CDATA[The open source platform for numerical computation]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Illanes Manriquez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An algorithm for QRS onset and offset detection in single lead electrocardiogram records]]></article-title>
<source><![CDATA[Proceedings of the 29th Annual International Conference of the IEEE EMBS]]></source>
<year>2007</year>
<volume>29</volume>
<page-range>541-544</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chacón]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Illanes-Manriquez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación de un algoritmo simple de detección de onda R con bases de datos estándares]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[Segundas Jornadas Chilenas de Ingeniería Biomédica]]></conf-name>
<conf-date>2009</conf-date>
<conf-loc>Viña del Mar </conf-loc>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Illanes Manriquez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Médigue]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Papelier]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Sorine]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An algorithm for robust and efficient location of T-wave ends in electrocardiograms]]></article-title>
<source><![CDATA[IEEE Transaction on Biomedical Engineering]]></source>
<year>2006</year>
<volume>53</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2544-2552</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chow]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Saghir]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bartone]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Goebel]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schneider]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Booth]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Usefulness of microvolt T-wave alternans on predicting outcome in patients with ischemic cardiomyopathy with and without defibrillators]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>2007</year>
<volume>100</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>598-604</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bloomfield]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Bigger]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Steinman]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Namerow]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Parides]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Curtis]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufman]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Davidenko]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shinn]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Fontaine]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microvolt T-wave alternans and the risk of death or sustained ventricular arrhythmias in patients with left ventricular dysfunction]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2005</year>
<volume>47</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>456-63</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>