<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5609</journal-id>
<journal-title><![CDATA[Ingeniería e Investigación]]></journal-title>
<abbrev-journal-title><![CDATA[Ing. Investig.]]></abbrev-journal-title>
<issn>0120-5609</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería, Universidad Nacional de Colombia.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-56092011000500011</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Generalised strategy for implementing the minimum fault reactance based fault location algorithm in real power distribution systems]]></article-title>
<article-title xml:lang="es"><![CDATA[Estrategia generalizada para la implementación del método de localización de fallas basado en la reactancia mínima de falla en sistemas de distribución reales]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Correa-Tapasco]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mora-Flórez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez-Londoño]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Tecnológica de Pereira, Colombia  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Tecnológica de Pereira, Colombia  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Tecnológica de Pereira, Colombia  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>10</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>10</month>
<year>2011</year>
</pub-date>
<volume>31</volume>
<fpage>71</fpage>
<lpage>75</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56092011000500011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56092011000500011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56092011000500011&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[The paper presented here is aimed at proposing a generalised strategyfor easily implementing a fault locator in real power distribution systems. The strategy is based on the definition of a fault location method and its successive application along section lines from a power substation to the section where the fault has been determined. According to the results, the proposed strategy seems to be applicable to real power systems as an alternative for reducing fault location time and thuskeeping good continuity indexes.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[En este artículo se propone una estrategia generalizada para fácilmente implementar un localizador de fallas en sistemas reales de distribución de energía eléctrica. La estrategia se fundamenta en la definición de un método de localización de fallas y su sucesiva aplicación a lo largo de las secciones de línea desde la subestación hasta donde se determine la localización de la falla. De acuerdo con los resultados, la estrategia propuesta es aplicable en sistemas de potencia reales como una alternativa para reducir el tiempo de localización de fallas y en consecuencia para mantener buenos índices de continuidad.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[fault location]]></kwd>
<kwd lng="en"><![CDATA[implementation strategy]]></kwd>
<kwd lng="en"><![CDATA[power distribution systems]]></kwd>
<kwd lng="es"><![CDATA[Localización de fallas]]></kwd>
<kwd lng="es"><![CDATA[estrategia de implementación]]></kwd>
<kwd lng="es"><![CDATA[sistemas de distribución de energía eléctrica]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size = "2" face = "verdana">      <p align="center"><font size="4"><b>Generalised strategy for implementing the minimum fault reactance based fault location algorithm in real power distribution systems</b></font></p>      <p align="center"><font size="3"><b>Estrategia generalizada para la implementaci&oacute;n del m&eacute;todo de localizaci&oacute;n de fallas basado en la reactancia m&iacute;nima de falla en sistemas de distribuci&oacute;n reales</b></font></p>      <p><b>E. Correa-Tapasco<sup>1</sup>, J. Mora-Fl&oacute;rez<sup>2</sup>, S. P&eacute;rez-Londo&ntilde;o<sup>3</sup></b></p>      <p><sup>1</sup> E. Correa-Tapasco: Ingeniero Electricista y Magister, Universidad Tecnol&oacute;gica de Pereira. Profesor catedr&aacute;tico, Universidad Tecnol&oacute;gica de Pereira, Colombia. <a href="mailto:ever@utp.edu.co">ever@utp.edu.co</a></p>     <p><sup>2</sup> J. Mora-Fl&oacute;rez: Ingeniero Electricista y Magister, Universidad Industrial de Santander. Doctor en Ingenier&iacute;a el&eacute;ctrica, Universidad de Girona. Profesor asociado, Universidad Tecnol&oacute;gica de Pereira, Colombia. <a href="mailto:jjmora@utp.edu.co">jjmora@utp.edu.co</a></p>     <p><sup>3</sup> S. P&eacute;rez-Londo&ntilde;o: Ingeniero Electricista y Magister, Universidad Tecnol&oacute;gica de Pereira. Estudiante de doctorado dela Universidad Nacional, Colombia. Profesora asociada, Universidad Tecnol&oacute;gica de Pereira, Colombia. <a href="mailto:saperez@utp.edu.co">saperez@utp.edu.co</a></p> <hr>      <p><b>ABSTRACT</b></p> The paper presented here is aimed at proposing a generalised strategyfor easily implementing a fault locator in real power distribution systems. The strategy is based on the definition of a fault location method and its successive application along section lines from a power substation to the section where the fault has been determined. According to the results, the proposed strategy seems to be applicable to real power systems as an alternative for reducing fault location time and thuskeeping good continuity indexes.</b></p>      <p><b>Keywords:</b> fault location, implementation strategy, power distribution systems.</b></p> <hr>     <p><b>RESUMEN</b></p> En este art&iacute;culo se propone una estrategia generalizada para f&aacute;cilmente implementar un localizador de fallas en sistemas reales de distribuci&oacute;n de energ&iacute;a el&eacute;ctrica. La estrategia se fundamenta en la definici&oacute;n de un m&eacute;todo de localizaci&oacute;n de fallas y su sucesiva aplicaci&oacute;n a lo largo de las secciones de l&iacute;nea desde la subestaci&oacute;n hasta donde se determine la localizaci&oacute;n de la falla. De acuerdo con los resultados, la estrategia propuesta es aplicable en sistemas de potencia reales como una alternativa para reducir el tiempo de localizaci&oacute;n de fallas y en consecuencia para mantener buenos &iacute;ndices de continuidad.</b></p>      ]]></body>
<body><![CDATA[<p><b>Palabras claves:</b> Localizaci&oacute;n de fallas, estrategia de implementaci&oacute;n, sistemas de distribuci&oacute;n de energ&iacute;a el&eacute;ctrica.</p> <hr>      <p><font size="3"><b>1. Introduction</b></font></p>      <p>Power systems are usually exposed to faults caused by a variety of circumstances such as lightning, accidental contact with trees or conductive materials, storms and hurricanes. These faults affect power quality, reducing the two well-known continuity indexes, the system availability interruption frequency index (SAIFI) and the system availability interruption duration index (SAIDI) (Bollen,2000; Dugan <i>et al.</i>,1999, pp. 1164-1169). These indexes are an indirect measurement of maintenance staff response in the case of unpredictable power outages.</p>     <p>Fault location is considered the first step ina expeditious recovery strategy which is necessary for maintaining good power service continuity indexes. The fault location task is complex in the case of power distribution systems, mainly due to such systems' characteristics like the presence of laterals, tapped loads, multiple conductor gauge, un-transposed lines, single and three phase loads and measurements available only at the power substation (Mora-Florez<i>et al.</i>, 2007).</p>     <p>The methods usually used for determining fault location are those that use voltage and current measurements at a power substation to estimate the reactance from the measurement point to the faulted node (Das,1998; Novosel<i>et al.</i>,1998;Aggarwal<i>et al.</i>, 1997, pp. 184-187; Morales and Mora-Florez, 2009). However, most methods work in terms of fault location in a simplified line section.</p>     <p>Considering the differences in line sections presented in power distribution systems, this paper was aimed at presenting a complete methodological approach to applying a fault location method in real environments, considering such power systems' main characteristics described above.</p>      <p><font size="3"><b>2. Generalised strategy for implementing the proposed fault location method</b></font></p>      <p><b><i>A. Basic fault locator aspects </i></b></p>      <p>The model used to represent a power distribution system could be based on the simplified circuit presented in <a href="#f1">Figure 1</a>;<a href="#f2">Figure 2</a> presents another model which considers laterals. Such definition has been considered due to the proposed fault location technique's low complexity and also the locator'sdesired precision. The more complex the modelused then the better the results obtained in fault location. However, to determine all adequate parameter values is not always an easy task, due to power distribution system complexity and the lack of information, which unfortunately is relatively common in power utilities. Considering the above, several methods use simplified models which give useful results for solving the proposed fault location problem.</p>     <p align="center">	<a name="f1"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f1.jpg"></p>     ]]></body>
<body><![CDATA[<p align="center">	<a name="f2"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f2.jpg"></p>      <p>As previously explained, the proposed technique is an improvement of that initially presented in (Morales, <i>et al, </i>2007, pp. 49-54) and is implemented using the concept of minimum fault reactance because this method is very suitable due to low requirements. This method only requires the pre-fault and fault measurements of voltage and current at a power substation and serial line impedances.</p>     <p>Using the simplified circuit and the measurements at a power substation, two complex equations were obtained to relate voltage and current and the distance to the faulty node. Considering fault impedance as purely resistive, the proposed method was aimed at determining the feeder node where the absolute value of fault reactance had its minimum value. This node was obtained by systematic variation of the assumed fault distance along the analysed feeder. The feeder load was lumped at the farthest node to reduce uncertainty associated with this dynamic pattern. The methodology proposed here makes this method easily applied to any power distribution feeder, considering variation of the overhead structure configuration, conductor gauge, number of phases, tapped loads, amongst such systems' other characteristics.</p>      <p><b><i>B.  Generalised methodology followed for implementing the fault locator in real power distribution systems</i></b></p>      <p>Considering the simplified power system presented in <a href="#f1">Figure 1</a>, <i>VpsandIps </i>represented voltage and current in a pre-fault situation, <i>ZL </i>represented line section impedance between nodes X and X+1, and <i>ZC </i>represented the lumped node at final section node X+1. In real power distribution systems, <i>ZL </i>varies as a consequence of section length, thus other aspects such as line configuration and conductor gaugecould also differ in each line section.</p>     <p>The voltages, currents and impedances in pre-fault conditions were represented as presented in equations (<a href="#ec1">1</a>), (<a href="#ec2">2</a>) and (<a href="#ec3">3</a>). Subindex X represented the reference node.</p>     <p align="center">	<a name="ec1"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec1.jpg"></p>     <p align="center">	<a name="ec2"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec2.jpg"></p>     <p align="center">	<a name="ec3"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec3.jpg"></p>      <p><i>1) Equivalent circuit considering fault conditions </i></p>      ]]></body>
<body><![CDATA[<p>The equivalent circuit considering a fault is presented in <a href="#f3">Figure 3</a>.</p>      <p align="center">	<a name="f3"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f3.jpg"></p>        <p>From <a href="#f3">Figure 3</a> shows how fault distance <i>m </i>from node X to the faulted pointwasdetermined. Assuming that the line section is known, and line impedance <i>ZL </i>is given in ohms, then <i>m </i>was obtained as a per unit value. The value obtained for<i>m</i>was then multiplied by total line section lengthto obtain the distance from node X to the fault.</p>     <p>Methodologically, the initial assumption was to consider the first line section as the faulted section. In the case of determining a value of <i>m </i>higher than 1, it would show that the faulted section was beyond the analysed section. The fault location method would then be applied again in the next downstream section, considering the voltages and currents at this new section's initial node. This procedure was repeated until the value of <i>m</i>was obtained in the interval &#91;0, 1&#93;, meaning that it would be in the faulted section.</p>     <p>To determine the values of voltages at the initial node of the new analysed line section, the voltage at the endnode of the actual section would only need to be estimated, as presented in equations (<a href="#ec4">4</a>) and (<a href="#ec4">5</a>), considering pre-fault <i>(ps) </i>and fault <i>(sf) </i>situations, respectively.</p>      <p align="center">	<a name="ec4"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec4.jpg"></p>      <p><i>2) Lumped load</i></p>      <p>Considering the power system represented in <a href="#f1">Figure 1</a>, line impedance is a well-known parameter. However the lumped load would vary in each time instant, so the value of <i>ZC</i> presented in equation (<a href="#ec6">6</a>) would have to be determined.</p>     <p align="center">	<a name="ec6"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec6.jpg"></p>      <p>From figure 1, the pre-fault voltage at the initial node of the analysed section (X) would be given by equation (<a href="#ec7">7</a>).</p>     ]]></body>
<body><![CDATA[<p align="center">	<a name="ec7"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec7.jpg"></p>      <p>From (7), <i>ZC </i>could be obtained as a function of section line impedance and pre-fault voltages and currents, as presented in the set of equations given in (<a href="#ec8">8</a>).</p>     <p align="center">	<a name="ec8"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec8.jpg"></p>      <p>Only the voltage was updated in each linesection, while the current remained  constant  due the  proposed  lumped  load located at the end of all of the analysed line sections.</p>      <p><i>3)&nbsp; Analysis in pre-fault and fault conditions </i></p>      <p>Considering the faulted circuit presented in <a href="#f2">Figure 2</a>, the voltage at faulted node F and the fault current were obtained as given in (<a href="#ec9">9</a>) and (<a href="#ec9">10</a>), respectively. The fault reactance was then estimated as presented in (<a href="#ec9">11</a>).</p>     <p align="center">	<a name="ec9"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec9.jpg"></p>      <p>Equations  (<a href="#ec9">9</a>)  and  (<a href="#ec9">10</a>)   are functions of the previously defined impedances, the value of <i>m </i>and also of voltages and currents estimated at the initial node of the line sectionbeing analysed.</p>      <p><i>4)&nbsp; Estimation of the fault distance</i></p>      <p>Considering completely resistive fault reactance, the fault distance was then defined as being the value of <i>m </i>where the absolute value of fault reactance reached its minimum value, as presented in equation (<a href="#ec12">12</a>). An extensive simulation was performed considering variation in the value of <b><i>in </i></b>from 0 to 1 in 0.01steps but a simple algorithm for obtaining the minimum value could be used to avoid unnecessary calculations.</p>     ]]></body>
<body><![CDATA[<p align="center">	<a name="ec12"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec12.jpg"></p>      <p>If the minimum value obtained along the line section corresponded to node X+l, then the next line section would have to be analysed. The absolute fault reactance value decreased from the substation node to the faulted node and then increased from the faulted node to the last feeder node.</p>      <p><i>C. Analysis considering different fault types</i></p>      <p>The strategy presented in <a href="#f4">Figure 4</a> was proposed to determine the fault type. It required measuring voltage and current at the power substation and also defining a phase pickup current (It) to determine whether the system was faulty.</p>     <p align="center">	<a name="f4"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f4.jpg"></p>      <p>Having determined the fault type, Table I presents the different voltages and currents used in equation (<a href="#ec9">11</a>); voltages and currents at the faulted node were then obtained by using equations (<a href="#ec9">9</a>) and (<a href="#ec9">10</a>).</p>      <p><b><i>A. Programming structure</i></b></p>     <p>The generalised fault location algorithm proposed in this paper was coded in Matlab programming language, usin the structure presented in <a href="#f5">Figure 5</a>.</p>      <p><font size="3"><b>3. Tests and results</b></font></p>      <p><b><i>A. Analysed power system</i></b></p>      ]]></body>
<body><![CDATA[<p>The system analysed here is a 34.5 kV power distribution system located in Colombia and operated by Codensa-Endesa E.S.P. The feeder analysed is 29 km long and its nominal load is 95 A. <a href="#f6">Figure 6</a> presents a geographical referenced diagram of the power systemso analysed.</p>      <p><b><i>A. Defining the tests</i></b></p>      <p>The tests involved analysing single phase, phase to phase, double phase to ground and three phase faults along the main feeder (29 km length). Variations in fault resistance from 0 to 40 <b>Q </b>were also tested to determine the proposed fault locator's performance (Dagenhart, 2000, pp. 30-32.).</p>     <p align="center">	<a name="f5"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f5.jpg"></p>     <p align="center">	<a name="f6"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f6.jpg"></p>      <p><b><i>B. Obtained results </i></b></p>      <p>Figures  7  to   10   present  the  results   of absolute   error estimation for all analysed fault type,s considering several fault resistance values.  The absolute error <i>(Ae) </i>was estimated as presented in (<a href="#ec13">13</a>) (Mora, Carrillo and Barrera, 2007).      <p align="center">	<a name="ec13"></a><img src="img/revistas/iei/v31sup2/v31sup2a11ec13.jpg"></p>      <p><b><i>C. Result analysis</i></b></p>      <p>According to the results, considering faults from 0 to 40 &#8486;, maximum estimated error was around 20%. However, considering the fault resistances given in (Dagenhart, 2000, pp. 30-32.), the average reported fault resistance in the case of single phase faults gave values from 8 to 16 &#8486;. Considering the latter, the errors were below 10%. In the case of phase faults, where reported average values for the fault resistances ranged from 0.5 to 5 &#8486;, absolute estimated error was lower than 4%.</p>     ]]></body>
<body><![CDATA[<p>As clearly shown in the Figures, the error in fault distance estimation was proportional to the fault resistance value. According to the results, the proposed method would then be constrained to low impedance faults applications.</p>     <p>Considering the evaluated power distribution feederlength it was noticed how estimated error increasedthe farther away the fault was.</p>     <p align="center">	<a name="f7"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f7.jpg"></p>     <p align="center">	<a name="f8"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f8.jpg"></p>     <p align="center">	<a name="f9"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f9.jpg"></p>     <p align="center">	<a name="f10"></a><img src="img/revistas/iei/v31sup2/v31sup2a11f10.jpg"></p>      <p><font size="3"><b>4. Conclusions</b></font></p>      <p>A generalised methodology has been proposed in this paper to implement fault location methods in real power distribution systems, such as that based on minimising fault reactance. The results showed that this methodology was suitable for power distribution systems, givingsatisfactory results in fault location where location errors were below 10%, considering the maximum for the most probable fault resistance values. It has also been demonstrated that proposed approach contributes towards improving power continuity indexes in distribution systems by opportune zone fault location.</p>      <p><font size="3"><b>5. Acknowledgments</b></font></p>      <p>This work was partly financed by Codensa, COLCIENCIAS and Sena in Colombia through research contract 537-2008. The authors would like to thank M. Su&aacute;rez-S&aacute;nchez from Codensa   and   G.   Morales-Espa&ntilde;a   from   UIS   for   their contributions which helpedto improve the paper.</p> <hr>      ]]></body>
<body><![CDATA[<p><font size="3"><b>6. References</b></font></p>      <!-- ref --><p>Aggarwal, R. K., Aslan, Y., and Johns, A. T., An interactive approach to fault location on overhead distribution lines with load taps.,In Proc.Inst. Elect. Eng., Develop. Power Syst. Protection, Conf. Publ. 434, 1997, pp. 184- 187.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-5609201100050001100001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Bollen, M. H. J., Understanding Power Quality Problems: Voltages Sags and Interruptions.IEEE Press series on power engineering, New York,2000.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0120-5609201100050001100002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Dagenhart, J. B., The 40- ground-fault phenomenon.,IEEE Trans. Ind. Applications., Vol. 36, No. 1, Jan./Feb., 2000, pp. 30-32.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-5609201100050001100003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Das, R., Determining the locations of faults in distribution systems, Univ. Saskatchewan, Saskatoon, SK, Canada, Ph.D. dissertation, 1998.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0120-5609201100050001100004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Dugan, R., Brooks, D., McDermott, T., and Sundaram, A., Using voltage sag and interruption indices in distribution planning.,InProc. IEEE Power Eng. Soc. Winter Meeting, Vol. 2, 1999, pp. 1164-1169.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0120-5609201100050001100005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Mora-Florez, J., Carrillo, G., Barrera, B.,Fault Location in Power Distribution Systems Using a Learning Algorithm for Multivariable Data Analysis.,IEEE Transaction on Power Delivery, Vol. 22, 2007, pp. 1715-1721.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0120-5609201100050001100006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Morales, G., Mora-Florez, J., Elimination of Multiple Estimation for Fault Location in Radial Power Systems by Using Fundamental Single-End Measurements.,IEEE Transactions on power delivery, Vol. 24, No. 3, ISBN 0885-8977, July 2009.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-5609201100050001100007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Morales, G., Mora-Florez, J., and P&eacute;rez, S., M&eacute;todo de localizaci&oacute;n de fallas en sistemas de distribuci&oacute;n basado en gr&aacute;ficas de reactancia., JournalScientia et Technica., Universidad Tecnol&oacute;gica de Pereira, Vol. 34, 2007, pp. 49-54.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0120-5609201100050001100008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Novosel, D., Hart, D., and Myllymaki, J., System for locating faults and estimating fault resistance in distribution networks with tapped loads., U.S. Patent 5 839 093, 1998.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-5609201100050001100009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aggarwal]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Aslan]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Johns]]></surname>
<given-names><![CDATA[A. T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An interactive approach to fault location on overhead distribution lines with load taps]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ Develop. Power Syst. Protection, Conf. Publ. 434]]></conf-name>
<conf-date>1997</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bollen]]></surname>
<given-names><![CDATA[M. H. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Understanding Power Quality Problems: Voltages Sags and Interruptions.]]></article-title>
<source><![CDATA[IEEE Press series on power engineering]]></source>
<year>2000</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dagenhart]]></surname>
<given-names><![CDATA[J. B.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The 40- ground-fault phenomenon]]></article-title>
<source><![CDATA[IEEE Trans. Ind. Applications.]]></source>
<year>Jan.</year>
<month>/F</month>
<day>eb</day>
<volume>36</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>30-32</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Das]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determining the locations of faults in distribution systems]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dugan]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Brooks]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[McDermott]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Sundaram]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Using voltage sag and interruption indices in distribution planning]]></article-title>
<source><![CDATA[IEEE Power Eng. Soc.]]></source>
<year>1999</year>
<volume>2</volume>
<page-range>1164-1169</page-range><publisher-name><![CDATA[Winter Meeting]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mora-Florez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Carrillo]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Barrera]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fault Location in Power Distribution Systems Using a Learning Algorithm for Multivariable Data Analysis]]></article-title>
<source><![CDATA[IEEE Transaction on Power Delivery]]></source>
<year>2007</year>
<volume>22</volume>
<page-range>1715-1721</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morales]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Mora-Florez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Elimination of Multiple Estimation for Fault Location in Radial Power Systems by Using Fundamental Single-End Measurements]]></article-title>
<source><![CDATA[IEEE Transactions on power delivery]]></source>
<year>July</year>
<month> 2</month>
<day>00</day>
<volume>24</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morales]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Mora-Florez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Método de localización de fallas en sistemas de distribución basado en gráficas de reactancia]]></article-title>
<source><![CDATA[JournalScientia et Technica]]></source>
<year>2007</year>
<volume>34</volume>
<page-range>49-54</page-range><publisher-name><![CDATA[Universidad Tecnológica de Pereira]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Novosel]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Hart]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Myllymaki]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[System for locating faults and estimating fault resistance in distribution networks with tapped loads]]></source>
<year>1998</year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>