<article-title xml:lang="en"><![CDATA[Portable High Voltage Impulse Generator]]></article-title>
<article-title xml:lang="es"><![CDATA[Generador Portátil de Impulsos de Tensión.]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Buitrago]]></surname>
<given-names><![CDATA[M.P.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Roldán]]></surname>
<given-names><![CDATA[F.A.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,National University of Colombia Department of Electrical ]]></institution>
<addr-line><![CDATA[Manizales ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,National University of Colombia Department of Electrical ]]></institution>
<addr-line><![CDATA[Manizales ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,National University of Colombia Department of Electrical ]]></institution>
<addr-line><![CDATA[Manizales ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>10</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>10</month>
<year>2011</year>
</pub-date>
<volume>31</volume>
<fpage>159</fpage>
<lpage>164</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56092011000500024&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56092011000500024&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56092011000500024&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to with stand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and wave forms compared to other commercial impulse generators and the standard impulse wave simulator.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[En este trabajo se presenta un generador portátil de impulsos de tensión, diseñado y construido con un aislamiento hasta para 20 kV. El diseño fue basado en un trabajo previo en el cual se desarrolla un software de simulación implementado exclusivamente para ondas de impulso normalizadas. Los componentes empleados fueron en su totalidad de bajo presupuesto, comerciales y algunos generalmente no son usados en alta tensión. Con el generador de impulsos se obtuvieron resultados satisfactorios en cuanto a tiempos y formas de onda, comparados con otros generadores de impulsos comerciales y el simulador de ondas de impulso normalizadas. Los generadores de impulso utilizados en la industria y laboratorios eléctricos son normalmente de gran tamaño, costosos y fabricados para soportar trabajos en extra alta tensión, ocupando demasiado espacio e imposibilitando su transporte. De ahí la importancia de este proyecto, pues siendo portátil facilita realizar pruebas en elementos que no se puedan desplazar de su ubicación.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Electrical insulation]]></kwd>
<kwd lng="en"><![CDATA[voltage impulse generator]]></kwd>
<kwd lng="en"><![CDATA[insulation coordination]]></kwd>
<kwd lng="en"><![CDATA[power disruption]]></kwd>
<kwd lng="en"><![CDATA[standardised waves]]></kwd>
<kwd lng="en"><![CDATA[standardised wave simulator]]></kwd>
<kwd lng="es"><![CDATA[Aislamiento eléctrico]]></kwd>
<kwd lng="es"><![CDATA[Coordinación de aislamiento]]></kwd>
<kwd lng="es"><![CDATA[Disrupción eléctrica]]></kwd>
<kwd lng="es"><![CDATA[Generador de impulsos de tensión]]></kwd>
<kwd lng="es"><![CDATA[Ondas Normalizadas]]></kwd>
<kwd lng="es"><![CDATA[Simulador de Ondas de Impulso]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size = "2" face = "verdana">      <p align="center"><font size="4"><b>Portable High Voltage Impulse Generator</b></font></p>       <p align="center"><font size="3"><b>Generador Port&aacute;til de Impulsos de Tensi&oacute;n.</b></font></p>      <p><b>S. G&oacute;mez<sup>1</sup>, M.P. Buitrago<sup>2</sup>, F.A. Rold&aacute;n<sup>3</sup></b></p>      <p><sup>1</sup>Works is with the Department of Electrical, Electronical and Computational Engineering, National University of Colombia, Manizales.(e-mail: <a href="mailto:sgomezar@unal.edu.co">sgomezar@unal.edu.co</a>).</p>     <p><sup>2</sup>Is with the Department of Electrical, Electronical and Computational Engineering, National University of Colombia, Manizales.(email: <a href="mailto:mpbuitragov@unal.edu.co">mpbuitragov@unal.edu.co</a>)</p>     <p><sup>3</sup>Is with the Department of Electrical, Electronical and Computational Engineering, National University of Colombia, Manizales. (e-mail: <a href="mailto:faroldanh@unal.edu.co">faroldanh@unal.edu.co</a>).</p> <hr>      <p><b>ABSTRACT</b></p> This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to with stand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and wave forms compared to other commercial impulse generators and the standard impulse wave simulator.</p>      <p><b>Keywords:</b> Electrical insulation, voltage impulse generator, insulation coordination, power disruption, standardised waves, standardised wave simulator.</b></p> <hr>      <p><b>RESUMEN</b></p> En este trabajo se presenta un generador port&aacute;til de impulsos de tensi&oacute;n, dise&ntilde;ado y construido con un aislamiento hasta para 20 kV. El dise&ntilde;o fue basado en un trabajo previo en el cual se desarrolla un software de simulaci&oacute;n implementado exclusivamente para ondas de impulso normalizadas. Los componentes empleados fueron en su totalidad de bajo presupuesto, comerciales y algunos generalmente no son usados en alta tensi&oacute;n. Con el generador de impulsos se obtuvieron resultados satisfactorios en cuanto a tiempos y formas de onda, comparados con otros generadores de impulsos comerciales y el simulador de ondas de impulso normalizadas. Los generadores de impulso utilizados en la industria y laboratorios el&eacute;ctricos son normalmente de gran tama&ntilde;o, costosos y fabricados para soportar trabajos en extra alta tensi&oacute;n, ocupando demasiado espacio e imposibilitando su transporte. De ah&iacute; la importancia de este proyecto, pues siendo port&aacute;til facilita realizar pruebas en elementos que no se puedan desplazar de su ubicaci&oacute;n.</p>      ]]></body>
<body><![CDATA[<p><b>Palabras Claves:</b> Aislamiento el&eacute;ctrico, Coordinaci&oacute;n de aislamiento, Disrupci&oacute;n el&eacute;ctrica, Generador de impulsos de tensi&oacute;n, Ondas Normalizadas, Simulador de Ondas de Impulso.</p> <hr>      <p><font size="3"><b>1. Introduction</b></font></p>      <p>Dielectric strength tests of materials used as electrical insulators are part of widely used and internationally accepted quality tests or trials and they are subject to rules or standards established by corresponding institutions, such as the American Society for Testing of Materials (ASTM) and the International Electrotechnical Commission (IEC).</p>      <p>An insulation coordination study must be done to ensure that high voltage materials tolerate different over voltage through out their life. These techniques are used to select the dielectric strength or insulation level for high voltage materials which must be able to support normalised voltages having different wave forms (the most common types are lightning and switching).</p>      <p>Some authors, (ASTM,2004;IEC, 2001), have stated that impulse voltage generators capable of providing impulse waves large enough to cause a power disruption in the proof element are needed for dielectric strength testing. The tested material's electrical parameters, such as capacitance, can affect magnitude and the wave form applied by the generator. Such capacitance should thus be taken into account when measuring, adjusting and monitoring the voltage wave form.</p>     <p>An impulse generator was designed in (Lora,2008) where most ofthe project components were imported, expensive, not very commercial and built for very specific applications, this being the greatest disadvantage (high implementation costs).</p>      <p>A simulation and numerical optimisation tool was developed in (Carmano et al) which used a minimum squares variant to compare mathematical model output against the output system. This tool calculated electrical circuit values during impulse trials for elements which could be handled. It was stated that the optimisation model would be better as soon as the amount of difficult to obtain experimental data became expanded.</p>      <p>Another article (Electrical Testing Group) has shown how a voltage impulse generator is typically used in techniques for finding faults in electrical transmission and distribution systems in high and medium voltage, called high power reflectometry. It was concluded that an impulse generator allows testing transformers to obtain data representation, associated capacitance and fault detection regarding transformer insulation.</p>      <p>To complement the afore mentioned work, a voltage impulse wave simulator was developed, based on wave normalisation using a graph technique or nomogram studied in (Aguet and Ianoz, 1990) and previously used in the proposed simulation by (Idarraga and Rold&aacute;n, 2005), where it was only necessary to set the components to be simulated without obtaining preliminary experimental data to conduct an impulse wave analysis. A portable generator was thus designed from simulation results, considering the field application noted above; a portable impulse generator was then constructed giving normalised voltage waves for lightning and switching types, using low-cost implementation components. Because of the small scale design, there were limitations on the voltage generator supply as the generator only delivered up to 20kV impulse voltage waves.</p>      <p><font size="3"><b>2. Theoretical background</b></font>	</p>      ]]></body>
<body><![CDATA[<p>Voltage impulse generators produce waves which can be classified as impulse lightning and impulses witching, with 1.2-250 &micro;s standard front time and 50</b>-2,500 &micro;s for tail time (IEC Standard 60060-1, 1989).</p>      <p align="center"><a name="f1"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f1.jpg"></p>       <p><b><i>A. Time measurements for a lightning wave</i></b></p>      <p>Front time<i>T<sub>1</sub> </i>for a lightning impulse is 1.67 times time interval <i>T </i>(<a href="#f1">Figure 1</a>, (IEEE Standard 4, 1995)) between the instants when an impulse is 30% and 90% of peak value. Tail time <i>T<sub>2</sub></i> for a lightning impulse is the time interval between virtual origin </b><i>T<sub>o</sub> </i>and the instant on the tail when the voltage has decreased to half (50%) peak value. Standard tolerances for front and tail time are 30% and 20%, respectively (IEEE Standard 4, 1995; Kuffel and Zaengl, 1970).</p>      <p><i><b>B. Time measurement for a switching wave</b></i></p>      <p>Front time <i>T<sub>cr</sub></i>, is measured by reaching peak voltage, while tail </b>time T<sub>h</sub> is measured when maximum voltage drops to 50%. Standard front and tail time tolerances are 20% and 60%, respectively (IEEE Standard 4, 1995; Kuffel and Zaengl, 1970)</p>      <p><i><b>C. Impulse generator</b></i></p>      <p>The generalised schemes for a single stage with capacitive, resistive and inductive components are used to generate a standard impulse wave, as shown in <a href="#f2">Figure 2</a>.</p>       <p align="center"><a name="f2"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f2.jpg"></p>        <p>These kinds of circuit give an impulse wave as output (such as that in <a href="#f3">Figure 3</a>) resulting from subtracting two exponential functions (Aguet and Ianoz, 1990).</p>      ]]></body>
<body><![CDATA[<p align="center"><a name="f3"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f3.jpg"></p>       <p>Equation (<a href="#ec1">1</a>) describes this kind of impulse:</p>      <p align="center"><a name="ec1"></a><img src="img/revistas/iei/v31sup2/v31sup2a24ec1.jpg"></p>       <p>where, <i>p<sub>1</sub> </i>and <i>p</i><sub>2</sub> are  time   constants  depending  on  circuit components (Aguet and Ianoz, 1990).</p>      <p><i><b>D. Normalising the wave equation</b></i></p>      <p>According to (Aguet and Ianoz, 1990), impulse wave (<a href="#ec2">2</a>) is used for normalisation:</p>     <p align="center"><a name="ec2"></a><img src="img/revistas/iei/v31sup2/v31sup2a24ec2.jpg"></p>      <p>Such simplification is associated with a graph called nomogram or abacus </b>(shown in <a href="#f4">Figure 4</a>) (Aguet and Ianoz, 1990). This graph relates the determinant factor of voltage impulse shape &#945;, and the determinant coefficient of time </b>&theta;.</p>     <p align="center"><a name="f4"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f4.jpg"></p>      <p>Expressions for <b>T<sub>2</sub>/T1, T<sub>2</sub>/&theta; or T<sub>h</sub>/&theta; and T<sub>h</sub>/T<sub>cr</sub></b> are derived from the nomogram curves used for component and time calculations.</p>     ]]></body>
<body><![CDATA[<p>These equations simplify the characteristic component calculation for an impulse generator from the type of known voltage wave or voltage impulse wave regarding the components being used.</p>      <p><b><i>E. Characteristic coefficients</i></b></p>      <p>Characteristic coefficients <i>&alpha;</i><i>, &theta; </i>and <i>&eta; </i>are determined for each type of circuit according to the equations shown in <a href="#t1">Table 1</a>, which were obtained from (Aguet and Ianoz, 1990).</p>     <p align="center"><a name="t1"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t1.jpg"></p>      <p>The equations presented in <a href="#t2">Table 2</a>, which were obtained from (Aguet and Ianoz, 1990), can be used for calculating the components based on the selection of the kind of scheme.</p>     <p align="center"><a name="t2"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t2.jpg"></p>      <p><font size="3"><b>3. Experimental framework</b></font></p>      <p><b><i>A. Simulator</i></b></p>      <p>The standardised voltage impulse simulator shown in <a href="#f5">Figure 5</a> was designed using the Matlab platform guide</b>. This software allows the user to obtain the wave form for the type of selected circuit from five possible options by determining front and tail times for lightning or switching</b>. The component values can also be obtained the type of impulse, the selected circuit and capacitor values.</p>      <p align="center"><a name="f5"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f5.jpg"></p>      ]]></body>
<body><![CDATA[<p>The procedure can be summarised by the scheme presented in <a href="#f6"> Figure 6</a>.</p>     <p align="center"><a name="f6"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f6.jpg"></p>      <p>The simulator was used to test commercial generator databases and select appropriate values for space requirements, construction costs and electrical insulation. It was then decided to build the elements using the values described in <a href="#t3">Table 3</a>.</p>     <p align="center"><a name="t3"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t3.jpg"></p>      <p><b><i>B. Capacitors</i></b></p>      <p>The proposed capacitors had to with stand 20kV voltage and their small capacitances were not commercially available. For each condenser it was necessary to assemble a series of capacitors, insulated from each other by rigid polyurethane foam and encapsulated in acrylic, there by obtaining greater dielectric strength. The building models are shown in <a href="#f7">Figure 7(a)</a>  and <a href="#f7">7(b)</a>.</p>     <p><a href="#t4">Table 4</a> summarises the technical characteristics and required amounts of elements used to build the capacitors for the portable voltage impulse generator.</p>      <p align="center"><a name="f7"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f7.jpg"></p>     <p align="center"><a name="t4"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t4.jpg"></p>      <p><b><i>C. Resistors</i></b></p>      ]]></body>
<body><![CDATA[<p>The resistors were made from traditional electronic carbon resistors connected in series to with stand the required stress. The resistors were isolated from each other by using rigid polyurethane foam and encapsulating them in acrylic, there by obtaining greater dielectric strength. <a href="#t5">Table 5</a> shows the values for the resistors used; the resistance configuration for lightning is presented in <a href="#f7">Figure 7(c)</a>.</p>     <p align="center"><a name="t5"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t5.jpg"></p>      <p><i><b>D. Sphere Gap</b></i></p>      <p>The sphere gap is used as voltage switch in voltage impulse generators, as in IEEE Standard 4, 1995; Bedoya, 2004)</b>. Due to the impulse generator's designed voltage, the sphere gap was proposed for uniform field distribution, using horizontal arrangement and supported on an acrylic structure. The switch could thus be calibrated to the generator's maximum possible voltage.</p>     <p>The spheres had 30mm diameter and maximum 8 mm distance; they were made of aluminium and designed to with stand </b>a maximum 20kV voltage. The sphere gap is shown in <a href="#f7">Figure 7(d)</a></b>.</p>      <p><i><b>E. Power supply</b></i></p>      <p>The power supply was formed by a 120/7,000V elevator transformer followed by a Schenkel voltage doubler circuit, as proposed in (Aguet and Ianoz, 1990), to achieve maximum 15kV voltage. The circuit was built using two 0.07&micro;F/8000V capacitors and two rectifier diode shaving 7,000V peak inverse voltage.</p>      <p><font size="3"><b>4. Results and discussion</b></font></p>      <p>The portable voltage impulse generator was tested in the laboratory to confirm that the results conformed to established standards and were with in the tolerances set by them. Simulations were made to test the generator's performance.</p>     <p><a href="#t6">Table 6(a)</a> shows the data obtained from laboratory testing for a lightning impulse using the portable voltage impulse generator. The data obtained for a commercial impulse generator (having the same resistor and capacitor values) and the values calculated by the impulse wave simulator are also presented.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="t6"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t6.jpg"></p>       <p>The lightning impulse registered by the oscilloscope as described by (IEC Standard 60060</b>-1, 1989; IEEE Standard 4, 1995) is presented in <a href="#f8">Figure 8(a)</a> .</p>     <p><a href="#t6">Table 6(b)</a>  presents the measured switching impulse values from a portable voltage impulse generator compared to those supplied by the impulse wave simulator. The switching impulse recorded by the oscilloscope as described by (IEC Standard 60060-1, 1989; IEEE Standard 4, 1995)is presented in <a href="#f8">Figure 8(b)</a> .</p>      <p align="center"><a name="f8"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f8.jpg"></p>       <p>Lightning and switching impulses were with in established standards when error rate associated with the portable voltage impulse generator was with in such range (<a href="#t7">Table 7</a>).</p>     <p align="center"><a name="t7"></a><img src="img/revistas/iei/v31sup2/v31sup2a24t7.jpg"></p>      <p>The results showed that the errors calculated for lightning and switching impulses came with in the percentage limits set by the afore mentioned regulations.</p>     <p>The final version of the portable voltage impulse generator components is presented in <a href="#f9">Figure 9</a>. Tuning tests were performed with a bell-type insulator and the results showed that the generator outputs came within the range of tolerances mentioned above.</p>     <p align="center"><a name="f9"></a><img src="img/revistas/iei/v31sup2/v31sup2a24f9.jpg"></p>       <p><font size="3"><b>5. Conclusions</b></font></p>      ]]></body>
<body><![CDATA[<p>This paper has presented the design and construction of a portable voltage impulse generator. The proposed generator's performance was compared to that of commercial generators and the established standards for such instruments. The results came within the ranges established by the standards and the generator could thus be regarded as being valid.</p>     <p>The generator satisfied the main objective and needs proposed in this work due to the low cost of its implementation   and   its   comfortable  size   for   use   and transport.</p>     <p>Future work will be aimed at expanding insulation components and power supply level to encompass jobs in higher voltage ranges and diversify the number of components to be tested.</p>      <p><font size="3"><b>6. Acknowledgments</b></font></p>      <p>The authors are grateful to the Universidad Nacional de Colombia in Manizales, especially the High Voltage research group for their support in carrying out laboratory practice.     <p>This work was supported in part by the National University of Colombia, Manizales.</p> <hr>      <p><font size="3"><b>7. References</b></font></p>      <!-- ref --><p>Aguet, M. and Ianoz, M. Haute Tensi&oacute;n, Trait&eacute; D'Electricit&eacute; 2&eacute;me &Eacute;dition, Par&iacute;s, 1990.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-5609201100050002400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>ASTM Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials Using Impulse Waves, Standard ASTM International D3426-1997, Reapproved 2004.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0120-5609201100050002400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Bedoya, D. R.; "Dise&ntilde;o y construcci&oacute;n de un espinter&oacute;metro para alta tensi&oacute;n - impulso tipo rayo", Engineering Thesis, Department of Electrical, and Electroncial Engineering, Univ. Nacional de Colombia, Sede Manizales, 2004.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-5609201100050002400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Carmona, F.; Jim&eacute;nez, J. E. and V&aacute;zquez, F. "Modelado y simulaci&oacute;n del circuito generador de impulsos para el ensayo en transformadores", Department of informatic and numerical analisys, C&oacute;rdoba, Campus Rabanales, TR-14071.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0120-5609201100050002400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Electrical Testing Group, &quot;Reflectometr&iacute;a de alta energ&iacute;a mediante el uso del generador de impulsos", Inducor Ingenier&iacute;a S.A., Buenos Aires, &#91;en l&iacute;nea&#93;. Available on <a href="http://www.inducor.com.ar/investigacion.html"  target="_blank">http://www.inducor.com.ar/investigacion.html</b></a>.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0120-5609201100050002400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Idarraga, C. and Rold&aacute;n, F.: "Simulador de Ondas de Choque", presentado en VII Congreso Latinoamericano y IV Iberoamericano en Alta Tensi&oacute;n y Aislamiento El&eacute;ctrico, Panam&aacute;, 2005.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0120-5609201100050002400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>IEC Electric Strength of Insulating Materials_Test Methods Part 3: Additional Requirements for 1.2/50&micro;s Impulse Test, IEC Standard 60243-3, Jul. 2001.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0120-5609201100050002400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>IEC Standard 60060-1, Nov. 1989; IEC High-voltage test techniques. Part 1: General definitions and test requirements.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0120-5609201100050002400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>IEEE Standard 4 -1995, Aug. 1995;IEEE Techniques for High- Voltage Testing.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0120-5609201100050002400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Kuffel, E. and Zaengl, W.; High Voltage Engineering. Ed. Londres: Pergamon Press, 1970.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0120-5609201100050002400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Lora, A.J. "Dise&ntilde;o de un generador de impulsos de alta tensi&oacute;n basado en las normas ASTM-D3426 e IEC-60243-3 para ensayos de rigidez diel&eacute;ctrica de materiales polim&eacute;ricos s&oacute;lidos", Engineering Thesis, Science and Engineering Faculty, Univ. Cat&oacute;lica Per&uacute;, 2008.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0120-5609201100050002400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aguet]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ianoz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Haute Tensión, Traité D'Electricité]]></source>
<year>1990</year>
<edition>2</edition>
<publisher-loc><![CDATA[París ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<collab>ASTM</collab>
<source><![CDATA[Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials Using Impulse Waves, Standard ASTM International D3426-1997]]></source>
<year>2004</year>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bedoya]]></surname>
<given-names><![CDATA[D. R]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseño y construcción de un espinterómetro para alta tensión - impulso tipo rayo]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carmona]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Jiménez]]></surname>
<given-names><![CDATA[J. E]]></given-names>
</name>
<name>
<surname><![CDATA[Vázquez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Modelado y simulación del circuito generador de impulsos para el ensayo en transformadores]]></source>
<year></year>
<publisher-loc><![CDATA[Córdoba ]]></publisher-loc>
<publisher-name><![CDATA[Department of informatic and numerical analisys]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="book">
<collab>Electrical Testing Group</collab>
<source><![CDATA[Reflectometría de alta energía mediante el uso del generador de impulsos]]></source>
<year></year>
<publisher-loc><![CDATA[Buenos Aires ]]></publisher-loc>
<publisher-name><![CDATA[Inducor Ingeniería S.A.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Idarraga]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Roldán]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Simulador de Ondas de Choque]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ presentado en VII Congreso Latinoamericano y IV Iberoamericano en Alta Tensión y Aislamiento Eléctrico]]></conf-name>
<conf-date>2005</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="">
<collab>IEC</collab>
<source><![CDATA[Electric Strength of Insulating Materials_Test Methods Part 3: Additional Requirements for 1.2/50µs Impulse Test]]></source>
<year>Jul.</year>
<month> 2</month>
<day>00</day>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="">
<collab>IEC</collab>
<source><![CDATA[Standard 60060-1, Nov. 1989; IEC High-voltage test techniques. Part 1: General definitions and test requirements]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="">
<collab>IEEE</collab>
<source><![CDATA[Standard 4 -1995, Aug. 1995;IEEE Techniques for High- Voltage Testing.]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuffel]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Zaengl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<source><![CDATA[High Voltage Engineering]]></source>
<year>1970</year>
<publisher-name><![CDATA[Ed. Londres: Pergamon Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lora]]></surname>
<given-names><![CDATA[A.J]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseño de un generador de impulsos de alta tensión basado en las normas ASTM-D3426 e IEC-60243-3 para ensayos de rigidez dieléctrica de materiales poliméricos sólidos]]></source>
<year></year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>