<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5633</journal-id>
<journal-title><![CDATA[Revista Colombiana de Cardiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Colomb. Cardiol.]]></abbrev-journal-title>
<issn>0120-5633</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Colombiana de Cardiologia. Oficina de Publicaciones]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-56332016000300010</article-id>
<article-id pub-id-type="doi">10.1016/j.rccar.2015.09.005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Masa en cuello secundaria a electrodo de estimulación cardiaca abandonado]]></article-title>
<article-title xml:lang="en"><![CDATA[Neck mass secondary to an abandoned pacing lead]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bautista Vargas]]></surname>
<given-names><![CDATA[William Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sáenz Morales]]></surname>
<given-names><![CDATA[Luis Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Guerrero]]></surname>
<given-names><![CDATA[Diego Andrés]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de La Sabana  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Fundación Cardioinfantil  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>01</day>
<month>05</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>01</day>
<month>05</month>
<year>2016</year>
</pub-date>
<volume>23</volume>
<numero>3</numero>
<fpage>227.e1</fpage>
<lpage>227.e5</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56332016000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56332016000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56332016000300010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Mujer de 70 años de edad, con historia de un electrodo de estimulación cardiaca abandonado, que genera: un trastorno de la deglución y una deformidad estética que la hacen consultar en múltiples oportunidades. A pesar de que se planteó la opción del retiro quirúrgico, se logró una extracción endovascular por la tracción de un electrodo. Describimos la utilidad del eco intracardiaco y el catéter ENSnare®, para la extracción de los electrodos en este tipo de casos.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[70-year-old woman with a history of an abandoned pacing lead who developed a deglutition disorder and an aesthetic deformity that made her consult in multiple specialties. Even though surgical removal was considered, endovascular extraction was accomplished with the traction of the lead. We describe the usefulness of the intracardiac echocardiography and the ENSnare® catheter for this type of lead extractions.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Marcapasos]]></kwd>
<kwd lng="es"><![CDATA[Tumor]]></kwd>
<kwd lng="es"><![CDATA[Rotura cardiaca]]></kwd>
<kwd lng="en"><![CDATA[Pacemaker]]></kwd>
<kwd lng="en"><![CDATA[Tumour]]></kwd>
<kwd lng="en"><![CDATA[Heart rupture]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">     <p><a href="http://dx.doi.org/10.1016/j.rccar.2015.09.005" target="_blank">http://dx.doi.org/10.1016/j.rccar.2015.09.005</a></p>      <P align="center"><b><font size="4">Masa en cuello secundaria a electrodo de estimulaci&oacute;n cardiaca abandonado</font></b></P>     <P align="center"><b><font size="3">Neck mass secondary to an abandoned pacing lead</font></b></P>     <P align="center">William Fernando Bautista Vargas <SUP>a</SUP>, Luis Carlos S&aacute;enz Morales <SUP>b</SUP>, Diego Andr&eacute;s Rodr&iacute;guez Guerrero <SUP>a</SUP></P>      <P><sup>a</sup> Departamento de Electrofisiolog&iacute;a Cardiovascular, Universidad de La Sabana, Bogot&aacute;, Colombia    <br> <sup>b</sup> Departamento de Electrofisiolog&iacute;a y Arritmias, Fundaci&oacute;n Cardioinfantil, Bogot&aacute;, Colombia</P>       <P>Recibido el 16 de junio de 2015; Aceptado el 7 de septiembre de 2015 </P>      <p>Correo electr&oacute;nico:<a href="mailto:Williambautista679@gmail.com">Williambautista679@gmail.com</a> (William Fernando Bautista Vargas)</p>  <hr>     <P><B><font size="3">Resumen</font></B></P>       ]]></body>
<body><![CDATA[<P>Mujer de 70 a&ntilde;os de edad, con historia de un electrodo de estimulaci&oacute;n cardiaca abandonado, que genera: un trastorno de la degluci&oacute;n y una deformidad est&eacute;tica que la hacen consultar en m&uacute;ltiples oportunidades.</P>      <P>A pesar de que se plante&oacute; la opci&oacute;n del retiro quir&uacute;rgico, se logr&oacute; una extracci&oacute;n endovascular por la tracci&oacute;n de un electrodo.</P>      <P>Describimos la utilidad del eco intracardiaco y el cat&eacute;ter ENSnare<SUP><B>&reg;</B></SUP>, para la extracci&oacute;n de los electrodos en este tipo de casos.</P>      <P><B>Palabras clave</B>:  Marcapasos. Tumor. Rotura cardiaca.</P>  <HR>      <P><B>Abstract</B></P>      <P>70-year-old woman with a history of an abandoned pacing lead who developed a deglutition disorder and an aesthetic deformity that made her consult in multiple specialties.</P>      <P>Even though surgical removal was considered, endovascular extraction was accomplished with the traction of the lead.</P>      <P>We describe the usefulness of the intracardiac echocardiography and the ENSnare<SUP><B>&reg;</B></SUP> catheter for this type of lead extractions.</P>      <P><B>Keywords</B>: Pacemaker. Tumour. Heart rupture.</P>   <hr>     <P><B><font size="3">Introducci&oacute;n</font></B></P>     ]]></body>
<body><![CDATA[<P>Mujer de 70 a&ntilde;os de edad, con cuadro cl&iacute;nico de un a&ntilde;o de evoluci&oacute;n consistente en una sensaci&oacute;n de masa en el cuello, una disfagia y una secreci&oacute;n de material seroso por una herida en el cuello a nivel de la horquilla esternal. La paciente ten&iacute;a antecedente de implante de dispositivo de estimulaci&oacute;n cardiaca, el cual debi&oacute; ser explantado por infecci&oacute;n, 3 a&ntilde;os antes de su consulta. El explante fue realizado parcialmente por imposibilidad para la extracci&oacute;n del electrodo de estimulaci&oacute;n ventricular derecho, dado que se fractur&oacute; distalmente en el nivel de la vena subclavia izquierda. Los estudios posteriores de la radiolog&iacute;a convencional y la tomograf&iacute;a del cuello documentaron la presencia del electrodo en contig&uuml;idad con tumoraci&oacute;n en el cuello (<a href="#f1">fig. 1 A, B, C</a>).</P>      <P align="center"><a name="f1"></a><IMG SRC="img/revistas/rcca/v23n3/v23n3a10f1.jpg"></P>       <P>La paciente se llev&oacute; a junta m&eacute;dico-quir&uacute;rgica con propuesta de exploraci&oacute;n quir&uacute;rgica del cuello, no obstante, se decidi&oacute; un segundo intento de la extracci&oacute;n percut&aacute;nea por parte del servicio de electrofisiolog&iacute;a.</P>      <P><B><font size="3">Procedimiento</font></B></P>      <P>Bajo anestesia general, se realiz&oacute; el acceso femoral derecho con el introductor 8 Fr, se introdujo la camisa agilis<SUP><B>&reg;</B></SUP> y el cat&eacute;ter ENSnare<SUP><B>&reg;</B></SUP>, posteriormente se realiz&oacute; el acceso venoso femoral izquierdo con el introductor 11Fr, por el cual se pas&oacute; la sonda de ecograf&iacute;a intracardiaca. Se realizaron m&uacute;ltiples intentos de tracci&oacute;n del electrodo con evidencia de deformidad de la cavidad ventricular derecha e hipotensi&oacute;n arterial (<a href="#f2">figs. 2</a> y <a href="#f3">3</a>). Finalmente, se logra la captura del electrodo con el cat&eacute;ter ENSnare<SUP><B>&reg;</B></SUP>, logr&aacute;ndose el desplazamiento del mismo y la extracci&oacute;n exitosa por la v&iacute;a femoral derecha. La paciente sali&oacute; de la sala de procedimientos, normotensa, con ventilaci&oacute;n espont&aacute;nea y sin derrame peric&aacute;rdico.</P>      <P align="center"><a name="f2"></a><IMG SRC="img/revistas/rcca/v23n3/v23n3a10f2.jpg"></P>     <P align="center"><a name="f3"></a><IMG SRC="img/revistas/rcca/v23n3/v23n3a10f3.jpg"></P>         <P>En el seguimiento al mes, la paciente presentaba notable mejor&iacute;a cl&iacute;nica con: remisi&oacute;n de la lesi&oacute;n cut&aacute;nea y mejor&iacute;a de la disfagia (<a href="#f4">fig. 4</a>).</P>      <P align="center"><a name="f4"></a><IMG SRC="img/revistas/rcca/v23n3/v23n3a10f4.jpg"></P>       <P><B>Discusi&oacute;n</B></P>      ]]></body>
<body><![CDATA[<P>La extracci&oacute;n percut&aacute;nea de los electrodos de estimulaci&oacute;n es una pr&aacute;ctica que est&aacute; creciendo y se ha convertido en una rama de la electrofisiolog&iacute;a, que involucra nuevas tecnolog&iacute;as que tienen mucho que ofrecer.</P>      <P>El abandono de un electrodo genera: un riesgo de cualquier tipo de complicaci&oacute;n en un 20% de los casos, la migraci&oacute;n dentro del sistema cardiovascular se presenta hasta en el 5% de los casos, siendo m&aacute;s frecuente en los electrodos auriculares unipolares<SUP>1,2</SUP>. Se ha reportado migraci&oacute;n de estos electrodos: a la vena subclavia, a la vena innominada, a la arteria pulmonar, a la vena cava superior, a la vena yugular, al ventr&iacute;culo derecho y a las venas hep&aacute;ticas. Dentro de las posibles causas de esta migraci&oacute;n se incluyen: las extracciones fallidas, el s&iacute;ndrome de aplastamiento o la p&eacute;rdida de la ligadura distal cuando se abandona un electrodo<SUP>2</SUP>.</P>      <P>La migraci&oacute;n sin secuelas vasculares se considera una complicaci&oacute;n menor. Sin embargo, se pueden presentar secuelas como: oclusi&oacute;n parcial de la vena a donde ha migrado el electrodo en un 13,3% de los casos y oclusi&oacute;n total en el 11,1% de los casos. Se puede condicionar oclusi&oacute;n total de la subclavia en el 15,6% y oclusi&oacute;n parcial de la vena cava superior en el 6,7%<SUP>2</SUP>. Hasta en el 73% de los casos la porci&oacute;n migrada del electrodo abandonado est&aacute; adherido a la superficie vascular y requiere intervenciones de tipo quir&uacute;rgico; teniendo relaci&oacute;n directa con el nivel del corte del electrodo si &eacute;ste es proximal o distal. Las intervenciones y la exploraci&oacute;n quir&uacute;rgicas se han relacionado con perforaci&oacute;n del septum interauricular, el embolismo cerebral y la reacci&oacute;n pleural. En el otro extremo del espectro, se encuentran las migraciones de electrodos con exposici&oacute;n a la piel, que han requerido medidas tan sencillas como: el reparo muscular de la fascia, hasta intervenciones con la exploraci&oacute;n quir&uacute;rgica, para la extracci&oacute;n del electrodo expuesto<SUP>3,4</SUP>.</P>      <P>Las indicaciones m&aacute;s frecuentes de la extracci&oacute;n de un electrodo son: la infecci&oacute;n local en un 35% de los casos, la infecci&oacute;n sist&eacute;mica en un 24%, la disfunci&oacute;n de electrodos en un 10%, el trasplante cardiaco en un 1,6%, el desalojo en un 1,4% y la fractura en un 1,2%. Otras indicaciones menos conocidas, incluyen: el dolor cr&oacute;nico intratable en el 2,7% de los casos y la necesidad de realizar una resonancia magn&eacute;tica cuando el dispositivo abandonado no es condicionado para ello, o se encuentra fraccionado<SUP>3</SUP>.</P>      <P>Existen m&uacute;ltiples intervenciones para la extracci&oacute;n de dispositivos: la extracci&oacute;n manual (en donde no se usan camisas o dispositivos de extracci&oacute;n), la extracci&oacute;n mec&aacute;nica (con uso o no de &laquo;locking stylets&raquo;), la disecci&oacute;n con l&aacute;ser (uso de camisa l&aacute;ser excimer) y la extracci&oacute;n quir&uacute;rgica abierta. Los riesgos potenciales descritos con estos procedimientos, incluyen, hasta la muerte, que ha sido reportada hasta en el 0,8% de los casos usando la extracci&oacute;n percut&aacute;nea<SUP>4,5</SUP>.</P>      <P>La tasa de &eacute;xito de la extracci&oacute;n de los dispositivos es del 97,6% en hospitales que utilizan dispositivos con l&aacute;ser. El riesgo de fallar con la t&eacute;cnica mec&aacute;nica es del 1,4%, con la t&eacute;cnica l&aacute;ser del 0,8% y del 0% con la extracci&oacute;n abierta. El riesgo de perforaci&oacute;n con diferentes t&eacute;cnicas ha sido reportado hasta en el 0,9%<SUP>3,5</SUP>.</P>      <P>El consenso mundial de expertos clasifica las intervenciones: seg&uacute;n su complejidad, seg&uacute;n el numero de v&iacute;as venosas usadas; en la primera categor&iacute;a se considera el uso de una nueva v&iacute;a venosa diferente a la usada para el implante y en la segunda categor&iacute;a, cuando el uso de la misma v&iacute;a venosa de implante es usada para el explante. La elecci&oacute;n de una v&iacute;a de explante se debe evaluar seg&uacute;n la experiencia del operario, las herramientas disponibles y la complejidad del caso<SUP>3</SUP>.</P>      <P>La manipulaci&oacute;n percut&aacute;nea de los electrodos es una t&eacute;cnica novedosa que incluso ha servido para la reacomodaci&oacute;n de los electrodos desalojados postablaci&oacute;n<SUP>6,7</SUP>. La extracci&oacute;n por fractura del electrodo es la indicaci&oacute;n m&aacute;s frecuente hasta en un 48% de las extracciones en menores de 80 a&ntilde;os de edad, con un grado de recomendaci&oacute;n II, con nivel de evidencia b<SUP>3,8</SUP>. Se han reportado fracasos de extracci&oacute;n de los electrodos hasta en un 1,5%. Cuando se eval&uacute;a la v&iacute;a venosa utilizada para el procedimiento, el uso de un abordaje femoral es el m&aacute;s frecuente hasta en el 66,7% de los casos. El &eacute;xito reportado con t&eacute;cnicas de extracci&oacute;n mec&aacute;nica y dispositivos espec&iacute;ficos es hasta del 98,4%, con complicaciones mayores cercanas al 3% <SUP>9&ndash;11</SUP>.</P>      <P>En el caso presentado, la causa primaria de la extracci&oacute;n del dispositivo fue la infecci&oacute;n del bolsillo, con falla en la extracci&oacute;n del electrodo del ventr&iacute;culo derecho. En este caso cl&iacute;nico vale la pena mencionar que la complicaci&oacute;n fue tard&iacute;a de m&aacute;s de un a&ntilde;o, produciendo una deformidad est&eacute;tica y funcional para la paciente. Lo cual es una manifestaci&oacute;n poco frecuente en los casos de los electrodos abandonados<SUP>12</SUP>.</P>      <P><B><font size="3">Conclusi&oacute;n</font></B></P>      ]]></body>
<body><![CDATA[<P>La intervenci&oacute;n para la extracci&oacute;n de electrodos y el dispositivo es una estrategia segura en manos expertas. Siendo la principal indicaci&oacute;n para el explante, la infecci&oacute;n asociada al dispositivo.</P>      <P>La extracci&oacute;n percut&aacute;nea es: una t&eacute;cnica segura, efectiva, con altas tasas de &eacute;xito y un porcentaje bajo de complicaciones mayores; siendo &eacute;sta reproducible en sitios, con los insumos adecuados y la experticia suficiente.</P>    <P>El riesgo de migraci&oacute;n de extremos de los electrodos cortados puede presentarse de forma tard&iacute;a e incluso posterior a los tres a&ntilde;os de explante y corte del electrodo; como es el caso presentado.</P>      <P>El monitoreo con la ecograf&iacute;a intracardiaca durante la extracci&oacute;n permite al intervencionista: la visi&oacute;n directa, as&iacute; como, la revisi&oacute;n <I>in vivo</I> de la hemodinamia, la integridad de las cavidades y la presencia de derrame peric&aacute;rdico.</P>      <P>El uso de un equipo multidisciplinario, la revisi&oacute;n de la indicaci&oacute;n y la realizaci&oacute;n del procedimiento es una estrategia segura y adecuada para la extracci&oacute;n de los electrodos cuando la indicaci&oacute;n supera el riesgo del paciente.</P>      <P><B><font size="3">Responsabilidades &eacute;ticas</font></B></P>      <P><B>Protecci&oacute;n de personas y animales</B>. Los autores declaran que los procedimientos seguidos se conformaron a las normas &eacute;ticas del comit&eacute; de experimentaci&oacute;n humana responsable y de acuerdo con la Asociaci&oacute;n M&eacute;dica Mundial y la Declaraci&oacute;n de Helsinki.</P>      <P><B>Confidencialidad de los datos</B>. Los autores declaran que en este art&iacute;culo no aparecen datos de pacientes.</P>      <P><B>Derecho a la privacidad y consentimiento informado</B>. Los autores declaran que en este art&iacute;culo no aparecen datos de pacientes.</P>      <P><B>Conflicto de intereses</B></P>     ]]></body>
<body><![CDATA[<P>Los autores declaran no tener conflicto de intereses.</P>       <P><B>Bibliograf&iacute;a</B></P>     <!-- ref --><P>1. B&ouml;hm &Aacute;, Pint&eacute;r A, Duray G, Lehoczky D, Dud&aacute;s G, Tomcs&aacute;nyi I, et al. Complications Due to Abandoned Noninfected Pacemaker Leads. PACE. 2001; 24(12):1721-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474532&pid=S0120-5633201600030001000001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>2. Kutarski A, MaÅ‚ecka B, ZÄ…bek A, Pietura R. Broken leads with proximal endings in the cardiovascular system: serious consequences and extraction difficulties. Cardiol J &#123;Internet&#125;. 2013 &#123;cited 2015 Feb 12&#125;;20(2):161-9. Available from:.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474534&pid=S0120-5633201600030001000002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>3. Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm &#123;Internet&#125;. Heart Rhythm Society; 2009 Jul &#123;cited 2015 Jan 11&#125;;6(7):1085-104. Available from: <a href="http://www.ncbi.nlm.nih.gov/pubmed/19560098" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/19560098</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474536&pid=S0120-5633201600030001000003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>4. Henrikson C a, Brinker J a. How to prevent, recognize, and manage complications of lead extraction. Part I: avoiding lead extraction--infectious issues. Heart Rhythm &#123;Internet&#125;. 2008 Jul &#123;cited 2015 Feb 12&#125;;5(7):1083-7. Available from: <a href="http://www.ncbi.nlm.nih.gov/pubmed/18598970" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/18598970</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474538&pid=S0120-5633201600030001000004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     ]]></body>
<body><![CDATA[<!-- ref --><P>5. Wazni O, Epstein LM, Carrillo RG, Love C, Adler SW, Riggio DW, et al. Lead Extraction in the Contemporary Setting: The LExICon Study. An Observational Retrospective Study of Consecutive Laser Lead Extractions. J Am Coll Cardiol. &#123;Internet&#125;. Elsevier Inc.; 2010;55(6):579-86. Available from: <a href="http://dx.doi.org/10.1016/j.jacc.2009.08.070" target="_blank">http://dx.doi.org/10.1016/j.jacc.2009.08.070</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474540&pid=S0120-5633201600030001000005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>6. Schuchert A, Muto C, Maounis T, Frank R, Boulogne E, Polauck A, et al. Lead complications, device infections, and clinical outcomes in the first year after implantation of cardiac resynchronization therapy-defibrillator and cardiac resynchronization therapy-pacemaker. Europace. &#123;Internet&#125;. 2013 Jan &#123;cited 2015 Feb 12&#125;;15(1):71-6. Available from: <a href="http://www.ncbi.nlm.nih.gov/pubmed/22927665" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/22927665</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474542&pid=S0120-5633201600030001000006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>7. Kennergren C, Bjurman C, Wiklund R, G&auml;bel J. A single-centre experience of over one thousand lead extractions. Europace. &#123;Internet&#125;. 2009 May &#123;cited 2015 Feb 12&#125;;11(5):612-7. Available from: <a href="http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2675028&amp;tool=pmcentrez&amp;rendertype=Abstract" target="_blank">http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2675028&amp;tool=pmcentrez&amp;rendertype=Abstract</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474544&pid=S0120-5633201600030001000007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>8. Kempa M, Budrejko S, Piepiorka M, Rogowski J, Raczak G, KozÅ‚owski D. Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age. Kardiol Pol. &#123;Internet&#125;. 2013 Jan &#123;cited 2015 Feb 12&#125;;71(2):130-5. Available from: <a href="http://www.ncbi.nlm.nih.gov/pubmed/23575705" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/23575705</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474546&pid=S0120-5633201600030001000008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>9. Duque M, D&iacute;az JC, Mar&iacute;n JE, Aristiz&aacute;bal JM. Experiencia inicial con el retiro de electrodos de estimulaci&oacute;n cardiaca mediante una t&eacute;cnica de extracci&oacute;n percut&aacute;nea mec&aacute;nica. Revista Colombiana de Cardiolog&iacute;a. 2015; 22(3):136-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474548&pid=S0120-5633201600030001000009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     ]]></body>
<body><![CDATA[<!-- ref --><P>10. Yos	hida N, Yamada T, McElderry HT. Successful percutaneous repositioning of a dislodged pacemaker lead. Europace. &#123;Internet&#125;. 2014 Jan &#123;cited 2015 Feb 12&#125;;16(1):148. Available from: <a href="http://www.ncbi.nlm.nih.gov/pubmed/24092666" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/24092666</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474550&pid=S0120-5633201600030001000010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <!-- ref --><P>11. Carvalho E, Martins DC, Brenande G, Faria A. Case Report Percutaneous Retrieval of Intracardiac Foreign Body with a Novel Technique. Arq Bras Cardiol. 2006;2006-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2474552&pid=S0120-5633201600030001000011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></P>     <P>12. Kardiologii K, Medyczny U. L&#261;cznotkankowe pozostaÅ‚o&#347;ci po usuni&#281;tych elektrodach drog&#261; przezÅ¼yln&#261; Fibrotic tissue reflecting lead course after percutaneous leads extraction. Kardiologia Polska. 2011;619-20.</P> </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Böhm]]></surname>
<given-names><![CDATA[á]]></given-names>
</name>
<name>
<surname><![CDATA[Pintér]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Duray]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Lehoczky]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Dudás]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Tomcsányi]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications Due to Abandoned Noninfected Pacemaker Leads]]></article-title>
<source><![CDATA[PACE]]></source>
<year>2001</year>
<volume>24(12)</volume>
<page-range>1721-4</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kutarski]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[MaÅ‚ecka]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[ZÄ…bek]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pietura]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Broken leads with proximal endings in the cardiovascular system: serious consequences and extraction difficulties]]></article-title>
<source><![CDATA[Cardiol J]]></source>
<year>2013</year>
<volume>20(2)</volume>
<page-range>161-9</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wilkoff]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Love]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Byrd]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
<name>
<surname><![CDATA[Bongiorni]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[Carrillo]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[Crossley]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA)]]></article-title>
<source><![CDATA[Heart Rhythm Society]]></source>
<year>2009</year>
<volume>6(7)</volume>
<page-range>1085-104</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henrikson]]></surname>
<given-names><![CDATA[C a]]></given-names>
</name>
<name>
<surname><![CDATA[Brinker]]></surname>
<given-names><![CDATA[J a]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[How to prevent, recognize, and manage complications of lead extraction. Part I: avoiding lead extraction--infectious issues]]></article-title>
<source><![CDATA[Heart Rhythm]]></source>
<year>2008</year>
<month> J</month>
<day>ul</day>
<volume>5(7)</volume>
<page-range>1083-7</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wazni]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Epstein]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Carrillo]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[Love]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Adler]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Riggio]]></surname>
<given-names><![CDATA[DW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lead Extraction in the Contemporary Setting: The LExICon Study. An Observational Retrospective Study of Consecutive Laser Lead Extractions. J Am Coll Cardiol]]></article-title>
<source><![CDATA[Elsevier Inc]]></source>
<year>2010</year>
<volume>55(6)</volume>
<page-range>579-86</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schuchert]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Muto]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Maounis]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Frank]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Boulogne]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Polauck]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lead complications, device infections, and clinical outcomes in the first year after implantation of cardiac resynchronization therapy-defibrillator and cardiac resynchronization therapy-pacemaker]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2013</year>
<volume>15(1)</volume>
<page-range>71-6</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kennergren]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bjurman]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Wiklund]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gäbel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A single-centre experience of over one thousand lead extractions]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2009</year>
<month> M</month>
<day>ay</day>
<volume>11(5)</volume>
<page-range>612-7</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kempa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Budrejko]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Piepiorka]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rogowski]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Raczak]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[KozÅ‚owski]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age]]></article-title>
<source><![CDATA[Kardiol Pol]]></source>
<year>2013</year>
<month> J</month>
<day>an</day>
<volume>71(2)</volume>
<page-range>130-5</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duque]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Díaz]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Marín]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Aristizábal]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Experiencia inicial con el retiro de electrodos de estimulación cardiaca mediante una técnica de extracción percutánea mecánica]]></article-title>
<source><![CDATA[Revista Colombiana de Cardiología]]></source>
<year>2015</year>
<volume>22(3)</volume>
<page-range>136-43</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yoshida]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Yamada]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[McElderry]]></surname>
<given-names><![CDATA[HT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Successful percutaneous repositioning of a dislodged pacemaker lead]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2014</year>
<month> J</month>
<day>an</day>
<volume>16(1)</volume>
<page-range>148</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Martins]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Brenande]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Faria]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Case Report Percutaneous Retrieval of Intracardiac Foreign Body with a Novel Technique]]></article-title>
<source><![CDATA[Arq Bras Cardiol]]></source>
<year>2006</year>
<page-range>2006-8</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kardiologii]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Medyczny]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[L&#261;cznotkankowe pozostalo&#347;ci po usuni&#281;tych elektrodach drog&#261; przezzyln&#261; Fibrotic tissue reflecting lead course after percutaneous leads extraction]]></article-title>
<source><![CDATA[Kardiologia Polska]]></source>
<year>2011</year>
<page-range>619-20</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
