<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5633</journal-id>
<journal-title><![CDATA[Revista Colombiana de Cardiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Colomb. Cardiol.]]></abbrev-journal-title>
<issn>0120-5633</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Colombiana de Cardiologia. Oficina de Publicaciones]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-56332017000200182</article-id>
<article-id pub-id-type="doi">10.1016/j.rccar.2016.05.016</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Estudio in vitro de permeabilidad, porosidad y crecimiento celular en membranas electrohiladas para prótesis vasculares]]></article-title>
<article-title xml:lang="en"><![CDATA[In vitro permeability, porosity and cell growth study in electrospin membranes for vascular grafts]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valencia]]></surname>
<given-names><![CDATA[Raúl A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
<xref ref-type="aff" rid="Aaf"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[Yuliet]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[Simón]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ortiz]]></surname>
<given-names><![CDATA[Isabel C.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hoyos]]></surname>
<given-names><![CDATA[Lina M.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[John]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Pontificia Bolivariana  ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad Pontificia Bolivariana  ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad Pontificia Bolivariana  ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<volume>24</volume>
<numero>2</numero>
<fpage>182</fpage>
<lpage>190</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56332017000200182&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56332017000200182&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56332017000200182&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen  Introducción y objetivos:  En la actualidad la posibilidad de fabricación de implantes vasculares mediante la técnica de electrospinning ha ganado interés para vasos sanguíneos de diámetros pequeños. El potencial en aplicaciones vasculares reside en su capacidad de generar estructuras microporosas con gran área superficial. Sin embargo, poco se conoce del efecto de dicha microestructura y su espesor, tanto en las propiedades de transporte de masa como en la proliferación celular. El propósito de este trabajo es analizar la permeabilidad, la porosidad y el crecimiento celular en membranas electrohiladas para prótesis vasculares.  Métodos:  mediante electrohilado se fabricaron membranas para implantes de poliuretano con memoria de forma (Irogran) en dos espesores, muestra 0 entre 0,2 mm y 0,9 mm y muestra +1 entre 0,9 mm y 1,0 mm, sobre las cuales se sembraron fibroblastos cardiacos humanos por un periodo de incubación hasta de 10 días. La porosidad y permeabilidad se evaluaron mediante la norma ISO 7198 y la proliferación celular se analizó a través de microscopia óptica y electrónica de barrido (SEM). El número total de muestras fue 12 para cada espesor de referencia. El análisis de datos se llevó a cabo mediante una prueba tipo ANOVA.  Resultados:  las muestras +1 presentaron permeabilidad promedio de 55,5% menor que las 0, reducción de la porosidad de 10,24%, asociado a mayor crecimiento celular, evidenciado por sincitios celulares.  Conclusiones:  La variación de estructuras microporosas de gran área superficial para obtener implantes con la técnica de electrospinning, incide en el crecimiento celular y subsecuentemente en la permeabilidad y la porosidad, hecho que abre una gran oportunidad para su uso potencial en aplicaciones vasculares de diámetros pequeños.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract  Introduction and motivation:  Nowadays, the possibility of engineering vascular grafts by means of electrospinning has attracted interest for small-diameter blood vessels. Potential vascular application lies in their ability to generate microporous structures with a big surface area. However, little is know about the effect of such microstructure and its thickness, both regarding mass transportation as well as cell proliferation. The motivation of this work is to analyse the permeability, porosity and cell growth in electrospun membranes for vascular grafts.  Methods:  by electrospinning membranes for grafts made of memory polyurethane foam were fabricated in two thicknesses, sample 0 between 0.2 and 0.9 mm and sample +1 between 0.9 and 1.0 mm, amongst which human cardiac fibroblasts were grown during an incubation period of up to 10 days. Porosity and permeability were assessed according to ISO 7198 and cell proliferation was analysed with scanning optical and electronic microscopy (SEM). Total sample number was 12 for each baseline thickness. Data analysis was conducted by ANOVA test.  Results:  +1 samples presented an average permeability that was 55.5% lower than the 0 samples, 10.24% decrease in porosity associated to bigger cell growth, evidenced by syncytial cells.  Conclusion:  The variation of microporous structures of great surface area in order to obtain grafts by means of electrospinning technique affects cell growth and subsequently their permeability and porosity, thus offering an opportunity for its potential use in small-diameter vascular applications.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Prótesis de vasos sanguíneos]]></kwd>
<kwd lng="es"><![CDATA[Técnicas de cultivo celular]]></kwd>
<kwd lng="es"><![CDATA[Permeabilidad]]></kwd>
<kwd lng="es"><![CDATA[Porosidad]]></kwd>
<kwd lng="es"><![CDATA[Propiedades de superficie]]></kwd>
<kwd lng="en"><![CDATA[Blood vessel grafts]]></kwd>
<kwd lng="en"><![CDATA[Cell culture techniques]]></kwd>
<kwd lng="en"><![CDATA[Permeability]]></kwd>
<kwd lng="en"><![CDATA[Porosity]]></kwd>
<kwd lng="en"><![CDATA[Surface properties]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="">
<collab>OMS. (01 de 2015). Organización Mundial de la Salud</collab>
<source><![CDATA[Cardiovascular Diseases]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Ideal cardiovascular health metrics and risk of cardiovascular disease or mortality A meta-analysis]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fang]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Int J Cardiol]]></source>
<year>2016</year>
<volume>214</volume>
<page-range>279-83</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="">
<collab>Instituto Nacional de Salud de Colombia</collab>
<source><![CDATA[Observatorio Nacional de Salud]]></source>
<year>2014</year>
<publisher-loc><![CDATA[Bogotá ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<collab>Healthline</collab>
<source><![CDATA[Ischemic Cardiomyopathy]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A new vascular polyester prosthesis impregnated with cross-linked dextran]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Machy]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Carteron]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Jozefonvicz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[J Biomater Sci Polym]]></source>
<year>2002</year>
<volume>13</volume>
<page-range>963-75</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Vascular grafts.Experiment and modelling]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tura]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Southhampton,]]></source>
<year>2003</year>
<publisher-loc><![CDATA[United Kingdom ]]></publisher-loc>
<publisher-name><![CDATA[WIT Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Tissue engineering of vascular grafts]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergemeister]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Strobl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grasl]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Liska]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Schima]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Eur Surg]]></source>
<year>2013</year>
<volume>45</volume>
<page-range>187-93</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Degradable implant materials a review of synthetic absorbable polymers and their applications]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barrows]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
</person-group>
<source><![CDATA[Clin Mat]]></source>
<year>1986</year>
<volume>1</volume>
<page-range>233-57</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cardiovascular tissue engineering estate of art]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hirt]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hansen]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Eschenhagen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Circ Res]]></source>
<year>2014</year>
<volume>114</volume>
<page-range>354-67</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="">
<collab>FDA</collab>
<source><![CDATA[Guidance for Industry and FDA Staff. Guidance document for Vascular Prostheses 510(k)]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Modelling blood flow through vascular grafts C98-P01.]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenhalgh]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Dunn]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Philadelphia College of Textile and Science]]></source>
<year>1998</year>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Electrospun cellular microenviromental Understending controlled release and Scaffold structure]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Szentivanyi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Chakradeo]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zernetsch]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Glasmacher]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<source><![CDATA[Advanced Drug Delivery Review]]></source>
<year>2011</year>
<volume>63</volume>
<numero>4-5</numero>
<issue>4-5</issue>
<page-range>209-20</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Advances in nanofibrous scaffolds for biomedical applications From electrospinning to self-assembly]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wade]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Burdick]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<source><![CDATA[Nanotoday]]></source>
<year>2014</year>
<volume>9</volume>
<page-range>722-42</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Bioresorbable elastomeric vascular tissue engineering scaffolds via melt spinning and electrospinning]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ingle]]></surname>
<given-names><![CDATA[NP]]></given-names>
</name>
<name>
<surname><![CDATA[Montero]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[King]]></surname>
<given-names><![CDATA[MW]]></given-names>
</name>
</person-group>
<source><![CDATA[Acta Biomaterialia]]></source>
<year>2010</year>
<volume>6</volume>
<page-range>1958-67</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Through-thickness permeability prediction of three-dimensional multifilament woven fabrics Composites Part A]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nabovati]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Llewellin]]></surname>
<given-names><![CDATA[EW]]></given-names>
</name>
<name>
<surname><![CDATA[Sousa]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
</person-group>
<source><![CDATA[Applied Science and Manufacturing.]]></source>
<year>2010</year>
<volume>41</volume>
<page-range>453-63</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Tissue engineering of vascular grafts]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergmeister]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Strobl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grasl]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Liska]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Schima]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Eur Surg]]></source>
<year>2013</year>
<volume>45</volume>
<page-range>187-93</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Electrospun scaffolds for tissue engineering of vascular grafts]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hasan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Memic]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Annabi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hossain]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Paul]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Dokmeci]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<source><![CDATA[Acta Biomaterialia]]></source>
<year>2014</year>
<volume>10</volume>
<page-range>11-25</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Fabrication of polyurethane and polyurethane based composite fibers by the electrospinning technique for soft tissue engineering of cardiovascular system]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kucinska-Lipka]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gubanska]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Janik]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Sienkiewicz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Material Science and Engineering:C]]></source>
<year>2015</year>
<volume>46</volume>
<page-range>166-76</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[The influence of feber thickness, wall thickness and gap distance on the spiral nanofibrous scaffolds for bone tissue engineering]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<source><![CDATA[Material Science and Engineering C]]></source>
<year>2011</year>
<volume>31</volume>
<page-range>50-6</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="">
<article-title xml:lang=""><![CDATA[Cardiovascular implants; Tubular vascular prostheses]]></article-title>
<collab>International standard ISO/DIS 7198</collab>
<source><![CDATA[]]></source>
<year>1998</year>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pulido]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
<name>
<surname><![CDATA[Salazar]]></surname>
<given-names><![CDATA[Rd]]></given-names>
</name>
</person-group>
<source><![CDATA[Diseños Factoriales. Análisis y diseño de experimentos]]></source>
<year>2012</year>
<edition>Tercera ed</edition>
<page-range>115-48</page-range><publisher-loc><![CDATA[México ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>