<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2010000100003</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Prótesis parcial fija: análisis biomecánico sobre distribución de esfuerzos entre tres alternativas de retención]]></article-title>
<article-title xml:lang="en"><![CDATA[Fixed partial prosthesis: biomechanical analysis of stress distribution among three retention alternatives]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Chica]]></surname>
<given-names><![CDATA[Edwin]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Latorre]]></surname>
<given-names><![CDATA[Federico]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Agudelo]]></surname>
<given-names><![CDATA[Sergio]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Ingeniería ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Antioquia Facultad de Ingeniería ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2010</year>
</pub-date>
<volume>21</volume>
<numero>2</numero>
<fpage>150</fpage>
<lpage>158</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2010000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2010000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2010000100003&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: el propósito de este estudio fue analizar la distribución de los esfuerzos entre tres alternativas de retención de una prótesis dental parcial fija de tres unidades, utilizando el método de elementos finitos (MEF). MÉTODOS: se realizaron tres modelos tridimensionales en elementos finitos del tramo dental anterior superior, restaurando uno con postes colados, otro con postes prefabricados y el tercero con implantes. Los modelos del tramo restaurado fueron modelados con hueso esponjoso, hueso cortical, ligamento periodontal, encía, raíz, gutapercha, cemento resinoso, poste, muñón de resina (modelos postes prefabricados), cofia metálica y corona cerámica. El material de los postes considerado para el análisis fue una aleación de metal noble (postes colados) y fibra de vidrio (postes prefabricados). Los postes fueron cementados con cemento resinoso. Se hizo un análisis lineal y se consideró las no linealidades asociadas a la geometría del modelo. Las variables incluidas en el modelado fueron el módulo de elasticidad y la razón de Poisson. Se aplicó una carga monótamente creciente de 1N en la superficie lingual de la corona con una inclinación de 45&ordm;. Los esfuerzos de von Mises fueron determinados. RESULTADOS: el análisis de elementos finitos indicó que la distribución de los esfuerzos generados en el diente modelado con los postes disminuyó significativamente, de acuerdo con una relación inversamente proporcional al módulo de elasticidad del material. En el modelo con implante, los esfuerzos se concentraron en la zona cervical y en el implante mismo. CONCLUSIONES: con las limitantes de este estudio, se encontró que existen variaciones marcadas con respecto a la distribución de los esfuerzos en las tres alternativas de retención, donde un sistema con varios componentes de diferente rigidez es cargado, el elemento más rígido resiste los mayores esfuerzos sin distorsión.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: the purpose of this study was to analyze the stress distribution among three retention alternatives used in a three unit fixed partial prosthesis, using the Finite Element Analysis (FEA). METHODS: three tridimensional FEA models of the upper anterior area, restored with a cast post, another with a prefabricated post and the third one with an implant, were prepared. The models of the restored area consisted of trabecular bone, cortical bone, periodontal ligament, gingival, root, gutta-percha, resin luting cement, post, composite resin core (for prefabricated posts), metallic core and metal ceramic crown. The post materials considered for analysis were a noble casting alloy and fiber glass. The posts were cemented with resin luting cement. A lineal analysis was carried out and the nonlinearities associated with the geometry of the model, were considered. The variables included in the model were the modulus of elasticity and Poisson&acute;s ratio. An increasing load of 1N was applied on the lingual surface of the crown with an inclination of 45&deg;. Von Mises stress were then calculated. RESULTS: the Finite Element Analysis showed that the distribution of stresses generated on the tooth modeled with posts, decreased significantly, in accordance with an inverse proportional relation with the modulus of elasticity of the material. In the implant model, the stresses concentrated on the cervical area and on the implant itself. CONCLUSIONS: within the limitations of this study, it was found that that there were marked differences in relation with the stress distribution among the three retention alternatives, where the system with different rigidity components is loaded, the most rigid element is capable of resisting the highest stress without distortion.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[poste]]></kwd>
<kwd lng="es"><![CDATA[elementos finitos]]></kwd>
<kwd lng="es"><![CDATA[implante]]></kwd>
<kwd lng="en"><![CDATA[post]]></kwd>
<kwd lng="en"><![CDATA[finite element]]></kwd>
<kwd lng="en"><![CDATA[fixed partial prosthesis]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Pr&oacute;tesis parcial fija: an&aacute;lisis biomec&aacute;nico sobre distribuci&oacute;n de esfuerzos entre tres alternativas de retenci&oacute;n</b></font></p>          <p>&nbsp;</p>           <p align="center"><font size="3" face="Verdana"><b>Fixed partial prosthesis: biomechanical analysis of stress distribution among three retention alternatives</b></font></p>           <p>&nbsp;</p>          <p>&nbsp;</p>           <p><b>Edwin Chica<sup>1</sup>; Federico Latorre<sup>2</sup>; Sergio Agudelo<sup>3</sup></b></p>         <p><sup>1</sup> Ingeniero mec&aacute;nico, maestr&iacute;a en Ingenier&iacute;a, especializaci&oacute;n en Dise&ntilde;o Mec&aacute;nico, profesor Facultad de Ingenier&iacute;a. Universidad de Antioquia. Correo electr&oacute;nico: <a href="mailto: echica@udea.edu.co">echica@udea.edu.co</a>    ]]></body>
<body><![CDATA[<br>  <sup>2</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto, profesor asociado Facultad de Odontolog&iacute;a, Universidad de Antioquia. Correo electr&oacute;nico: <a href="flatorre@une.net.co">flatorre@une.net.co</a>    <br>      <sup>3</sup> Ingeniero Mec&aacute;nico, especializaci&oacute;n en Mantenimiento, profesor Facultad de Ingenier&iacute;a. Universidad de Antioquia. Correo electr&oacute;nico: <a href="mailto: seragude@udea.edu.co">seragude@udea.edu.co</a>    <br></p>       <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> el prop&oacute;sito de este estudio fue analizar la distribuci&oacute;n de los esfuerzos entre tres alternativas de retenci&oacute;n de una pr&oacute;tesis dental parcial fija de tres unidades, utilizando el m&eacute;todo de elementos finitos (MEF).    <br>  <b>M&Eacute;TODOS:</b> se realizaron tres modelos tridimensionales en elementos finitos del tramo dental anterior superior, restaurando uno con postes colados, otro con postes prefabricados y el tercero con implantes. Los modelos del tramo restaurado fueron modelados con hueso esponjoso, hueso cortical, ligamento periodontal, enc&iacute;a, ra&iacute;z, gutapercha, cemento resinoso, poste, mu&ntilde;&oacute;n de resina (modelos postes prefabricados), cofia met&aacute;lica y corona cer&aacute;mica. El material de los postes considerado para el an&aacute;lisis fue una aleaci&oacute;n de metal noble (postes colados) y fibra de vidrio (postes prefabricados). Los postes fueron cementados con cemento resinoso. Se hizo un an&aacute;lisis lineal y se consider&oacute; las no linealidades asociadas a la geometr&iacute;a del modelo. Las variables incluidas en el modelado fueron el m&oacute;dulo de elasticidad y la raz&oacute;n de Poisson. Se aplic&oacute; una carga mon&oacute;tamente creciente de 1N en la superficie lingual de la corona con una inclinaci&oacute;n de 45&ordm;. Los esfuerzos de von Mises fueron determinados.    <br>  <b>RESULTADOS:</b> el an&aacute;lisis de elementos finitos indic&oacute; que la distribuci&oacute;n de los esfuerzos generados en el diente modelado con los postes disminuy&oacute; significativamente, de acuerdo con una relaci&oacute;n inversamente proporcional al m&oacute;dulo de elasticidad del material. En el modelo con implante, los esfuerzos se concentraron en la zona cervical y en el implante mismo.    <br>  <b>CONCLUSIONES:</b> con las limitantes de este estudio, se encontr&oacute; que existen variaciones marcadas con respecto a la distribuci&oacute;n de los esfuerzos en las tres alternativas de retenci&oacute;n, donde un sistema con varios componentes de diferente rigidez es cargado, el elemento m&aacute;s r&iacute;gido resiste los mayores esfuerzos sin distorsi&oacute;n.</p>          ]]></body>
<body><![CDATA[<p><b>Palabras clave:</b> poste, elementos finitos, implante.</p>   <hr noshade>           <p><b>ABSTRACT</b></p>           <p><b>INTRODUCTION:</b> the purpose of this study was to analyze the stress distribution among three retention alternatives used in a three unit fixed partial prosthesis, using the Finite Element Analysis (FEA).    <br>  <b>METHODS:</b> three tridimensional FEA models of the upper anterior area, restored with a cast post, another with a prefabricated post and the third one with an implant, were prepared. The models of the restored area consisted of trabecular bone, cortical bone, periodontal ligament, gingival, root, gutta-percha, resin luting cement, post, composite resin core (for prefabricated posts), metallic core and metal ceramic crown. The post materials considered for analysis were a noble casting alloy and fiber glass. The posts were cemented with resin luting cement. A lineal analysis was carried out and the nonlinearities associated with the geometry of the model, were considered. The variables included in the model were the modulus of elasticity and Poisson&acute;s ratio. An increasing load of 1N was applied on the lingual surface of the crown with an inclination of 45&deg;. Von Mises stress were then calculated.    <br>  <b>RESULTS:</b> the Finite Element Analysis showed that the distribution of stresses generated on the tooth modeled with posts, decreased significantly, in accordance with an inverse proportional relation with the modulus of elasticity of the material. In the implant model, the stresses concentrated on the cervical area and on the implant itself.    <br>  <b>CONCLUSIONS:</b> within the limitations of this study, it was found that that there were marked differences in relation with the stress distribution among the three retention alternatives, where the system with different rigidity components is loaded, the most rigid element is capable of resisting the highest stress without distortion.</p>      <p><b>Key words:</b> post, finite element, fixed partial prosthesis.</p>  <hr noshade>     <p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      ]]></body>
<body><![CDATA[<p>Es frecuente que un alto porcentaje de pacientes con problemas dentales requieran una pr&oacute;tesis parcial fija (PPF), la cual utiliza pilares para su fijaci&oacute;n que eventualmente pueden ser dientes adyacentes al espacio ed&eacute;ntulo. Debido a la p&eacute;rdida de la estructura dentaria, estos pilares frecuentemente requieren postes colados o postes prefabricados que son cementados en las ra&iacute;ces con una estructura disminuida, para facilitar la retenci&oacute;n de las coronas cer&aacute;micas. En ausencia de la ra&iacute;z del diente, existe la posibilidad de lograr la retenci&oacute;n sobre implantes dentales, los cuales, una vez oseointegrados al hueso del maxilar, soportar&aacute;n la PPF.</p>      <p>Estas tres alternativas de retenci&oacute;n de tramos prot&eacute;sicos, el empleo de un poste colado o prefabricado o el uso de implante, est&aacute;n a criterio del cl&iacute;nico, qui&eacute;n teniendo en cuenta par&aacute;metros como la estructura dental remanente, la calidad y la cantidad del hueso, la funci&oacute;n, los costos y la salud sist&eacute;mica entre otros, pueden seleccionar el mejor elemento restaurador para cada caso.<sup>1-4</sup></p>      <p>Si la alternativa de retenci&oacute;n seleccionada es con postes, el profesional se ve enfrentado nuevamente a la encrucijada de elegir entre los postes colados o los postes prefabricados, para dar soporte y estabilidad a la pr&oacute;tesis dental.<sup>5, 6</sup></p>      <p>Tradicionalmente los elementos intrarradiculares se han fabricado en metales base o nobles, que tienen un m&oacute;dulo de elasticidad m&aacute;s alto, raz&oacute;n por la cual se ha discutido el riesgo de fractura y p&eacute;rdida dental, debido a que en la dentina, estos elementos distribuyen los esfuerzos en forma m&aacute;s heterog&eacute;nea por las propiedades del material.<sup>7-10</sup></p>      <p>Autores como Asmussen et al.<sup>11</sup> controvierten las afirmaciones del riesgo de fracturas, argumentando fallas en la interpretaci&oacute;n de los estudios que defienden esta afirmaci&oacute;n.</p>      <p>Por el riesgo de fracturas, se ha asumido que el uso de materiales con un m&oacute;dulo de elasticidad similar al de la dentina, permite distribuir en forma homog&eacute;nea los esfuerzos, disminuyendo as&iacute; las posibilidades de fractura de la ra&iacute;z. Para cumplir con estas necesidades, las casas comerciales han desarrollado postes no met&aacute;licos en fibra de vidrio o fibra de carbono, que presentan ventajas como: la resistencia a la fatiga, la resistencia a la corrosi&oacute;n, son biocompatibles, mejoran la posibilidad de la adhesi&oacute;n y tienen mejor posibilidad de retiro en caso de fractura del poste. De acuerdo con los estudios actuales, sigue existiendo controversia sobre cu&aacute;l modelo es mejor y si alguno de ellos protege el sistema o por el contrario, un m&oacute;dulo de elasticidad, tanto alto como bajo, no contribuyen en la posibilidad de fractura, ya que el principal par&aacute;metro ser&iacute;a la calidad y la cantidad de la dentina remanente.<sup>12-14</sup></p>      <p>Cuando el sistema de retenci&oacute;n es un implante dental, es importante evaluar la distribuci&oacute;n de los esfuerzos y la diferencia en el comportamiento biomec&aacute;nico con el diente natural.</p>      <p>Uno de los m&eacute;todos que se dispone para ello es el m&eacute;todo de elementos finitos. Este es un procedimiento num&eacute;rico para resolver ecuaciones diferenciales que caracterizan un problema de manera aproximada. Con el m&eacute;todo, una estructura compleja como lo es un diente se divide en peque&ntilde;os elementos denominados elementos finitos, cuyo comportamiento se especifica mediante un n&uacute;mero finito de par&aacute;metros asociados a ciertos puntos caracter&iacute;sticos denominados nodos. Estos nodos son los puntos de uni&oacute;n de cada elemento con sus adyacentes. Con el m&eacute;todo una vez que la estructura se modela y convierte en formas geom&eacute;tricas simples (elementos finitos), las propiedades del material y las relaciones gobernantes son consideradas sobre esos elementos y expresadas en t&eacute;rminos de valores desconocidos en los nodos del elemento. Un proceso de ensamble, cuando se consideran debidamente las cargas y restricciones, da lugar a un conjunto de ecuaciones. La soluci&oacute;n de esas ecuaciones permite observar el comportamiento del modelo analizado. Con el m&eacute;todo se obtiene la distribuci&oacute;n de los esfuerzos, los cuales pueden ser tensiles, compresivos y de corte o una combinaci&oacute;n de ellos conocida como el esfuerzo de von Mises, el cual es un indicador o criterio de posible da&ntilde;o o riesgo en la estructura. El m&eacute;todo de elementos finitos fue desarrollado hace varios a&ntilde;os para resolver problemas estructurales en &aacute;reas como la ingenier&iacute;a y hace tiempo se utiliza en &aacute;reas de la salud para la simulaci&oacute;n de sistemas biol&oacute;gicos complejos. A continuaci&oacute;n se describe el procedimiento empleado para la modelaci&oacute;n y el an&aacute;lisis de un tramo de PPF.</p>      <p>Esta investigaci&oacute;n se realiz&oacute; con el prop&oacute;sito de evaluar la distribuci&oacute;n de los esfuerzos en los tres sistemas de retenci&oacute;n mediante el m&eacute;todo de elementos fi nitos de manera que entregue mejor informaci&oacute;n sobre el comportamiento biomec&aacute;nico de la pr&oacute;tesis fija de tres unidades con tres formas diferentes de retenci&oacute;n.</p>      <p>&nbsp;</p>      ]]></body>
<body><![CDATA[<p><font size="3" face="Verdana"><b>MATERIALES Y M&Eacute;TODOS</b></font></p>      <p>Para el an&aacute;lisis de la distribuci&oacute;n de los esfuerzos de los modelos presentados se utiliz&oacute; el m&eacute;todo de elementos.</p>      <p>Con el software CAD (Solid Edge V17) se model&oacute; una secci&oacute;n del maxilar superior que inclu&iacute;a un tramo de PPF <a href="#f1">figura 1a</a>. Los modelos del tramo prot&eacute;sico incluyeron, el incisivo central, el incisivo lateral (p&oacute;ntico) y el canino con sus tejidos de soporte y el elemento intrarradicular objeto de an&aacute;lisis, que fue igual para ambos pilares en el modelo de poste colado de metal noble (<a href="#f1">figura 1b</a>) y el modelo poste prefabricado de fibra de vidrio (<a href="#f1">figura 1c</a>).</p>      <p align="center"><a name="f1"><img src=img/revistas/rfoua/v21n2/v21n2a03f1.jpg></a> </p>      <p>Las dos alternativas de retenci&oacute;n con postes a su vez fueron comparadas con un modelo de una pr&oacute;tesis implanto-soportada <a href="#f1">figura 1d</a>. La geometr&iacute;a correspondiente a los tejidos duros (ra&iacute;z, hueso cortical y esponjoso) fue modelada a partir de im&aacute;genes planas obtenidas de una tomograf&iacute;a axial computarizada del cr&aacute;neo de un sujeto vivo. Para modelar el resto de componentes se tomaron medidas de piezas dentales empleadas en este tipo de restauraci&oacute;n.</p>      <p>Se escogi&oacute; el tramo mostrado en la figura 1a por: la forma c&oacute;nica de la ra&iacute;z del central y ovalada del canino lo que facilit&oacute; su modelado, por ser dientes unirradiculares, por la alta frecuencia de ausencia del incisivo lateral superior por trauma, por presentar malformaciones o el estar ausentes por factores gen&eacute;ticos.<sup>15, 16</sup></p>      <p>La ra&iacute;z del incisivo central y del canino fueron modelados con un mu&ntilde;&oacute;n de 2 mm de estructura coronal remanente, con un bisel de 1 mm en su periferia para obtener el efecto de f&eacute;rula. Para el dise&ntilde;o del conducto radicular se consider&oacute; que la amplitud del canal pulpar no superara un tercio de la amplitud radicular en su parte m&aacute;s estrecha; teniendo como m&iacute;nimo 1 mm de dentina sana a su alrededor, sobre todo en la regi&oacute;n del &aacute;pice.<sup>17, 18</sup></p>      <p>Los 4 mm apicales del conducto radicular fueron modelados con las propiedades de la gutapercha (material de obturaci&oacute;n para endodoncia), conservando as&iacute;, la cantidad m&iacute;nima de obturaci&oacute;n que se describe en la literatura para evitar la filtraci&oacute;n.<sup>19</sup></p>      <p>Para el resto del conducto radicular y su porci&oacute;n coronal se model&oacute; un elemento intrarradicular con dos geometr&iacute;as dependiendo de si la restauraci&oacute;n era con postes colados o prefabricados. En el caso de los postes colados, el espigo de retenci&oacute;n se tom&oacute; de di&aacute;metro coronal de 1,6 mm y apical de 1,1 mm, ajust&aacute;ndose a la anatom&iacute;a interna del canal radicular del central y el canino con su porci&oacute;n apical redondeada. La geometr&iacute;a y el tama&ntilde;o de los postes prefabricados fueron tomados de los elementos comercialmente disponibles (comercial Angelus). Adem&aacute;s fueron cementados con cemento resinoso en el canal radicular y modelado un mu&ntilde;&oacute;n con material de resina para proveer el soporte a la corona. Los postes fueron cementados con cemento resinoso para lo cual se model&oacute; una pel&iacute;cula de 0,04 mm.</p>      <p>La configuraci&oacute;n del mu&ntilde;&oacute;n o n&uacute;cleo guard&oacute; las proporciones de la preparaci&oacute;n para una corona completamente cer&aacute;mica de un incisivo central superior y de un canino superior izquierdo. Se gener&oacute; una reducci&oacute;n axial de 2 mm. Con esto se asegur&oacute; el espacio adecuado para la modulaci&oacute;n de la corona totalmente cer&aacute;mica, de la siguiente manera: el espesor de la porcelana fue de 2 mm. Todos estos par&aacute;metros ayudaron a que la restauraci&oacute;n cumpliera con los requisitos de est&eacute;tica y espesor adecuados para la resistencia del material y as&iacute; evitar los sobrecontornos. El ligamento periodontal se model&oacute; con un espesor en la periferia de la ra&iacute;z de 0,2 mm para todos los modelos.</p>      ]]></body>
<body><![CDATA[<p>Para el modelo con implante se consider&oacute; una referencia de la casa comercial Lifecore, implante RBM de 3,75 mm de di&aacute;metro por 13 de longitud. En el modelo con el implante (figura 1d) no se consider&oacute; ra&iacute;z ni ligamento periodontal, y se dise&ntilde;&oacute; con las siguientes partes: implante, tornillo, pilar, corona, hueso cortical, hueso esponjoso. El implante se model&oacute; con todos sus componentes, con un cilindro roscado de di&aacute;metro mayor de 3,75 mm y longitud de 13, el cual se torna c&oacute;nico en su parte inferior, tiene un roscado interno para la sujeci&oacute;n del pilar con el tornillo, una protrusi&oacute;n hex&aacute;gona en su parte superior para la uni&oacute;n con el pilar prot&eacute;sico para impedir que este gire y adem&aacute;s cuatro ranuras en su parte inferior que facilitan la fijaci&oacute;n en el hueso. El pilar se consider&oacute; como un cilindro c&oacute;nico de di&aacute;metro mayor de 5 mm y longitud de 8,4, con un agujero interno por el cual se inserta el tornillo, con un agujero hex&aacute;gono en su cara inferior para su uni&oacute;n con el implante, adem&aacute;s tiene una superficie plana en el cono para evitar el giro de la corona. Para el an&aacute;lisis se consider&oacute; que al instalar el implante se da un proceso de oseointegraci&oacute;n, en el cual el hueso cortical recubre el implante desde la primera rosca hasta su extremo inferior. Considerando el implante totalmente unido con el hueso cortical, se simul&oacute; la condici&oacute;n estable del estado cl&iacute;nico, es decir, se asume que ha pasado el tiempo requerido para la oseointegraci&oacute;n.<sup>20</sup></p>      <p>Para los tres modelos (<a href="#f1">figura 1 b</a>  <a href="#f1">c</a> <a href="#f1">d</a>) el hueso alveolar incluy&oacute; el hueso esponjoso que forma el interior del cuerpo maxilar y el hueso cortical que rode&oacute; tanto el maxilar como el alv&eacute;olo. El hueso cortical se consider&oacute; de 1 mm de espesor en la zona perif&eacute;rica desde la regi&oacute;n basal y de 0,5 mm hacia la regi&oacute;n interna del alv&eacute;olo. El incisivo superior se model&oacute; con una longitud total de 25 mm, la corona midi&oacute; 9 x 7,5 mm y la ra&iacute;z 16 x 5 mm, la longitud del canino fue de 27 mm, la corona 9 x 7,5 mm y la ra&iacute;z 18 x 5 mesiodistal x 6 mm buco lingual, en el incisivo lateral (p&oacute;ntico) la corona se model&oacute; de 8 x 6 mm.</p>      <p>Una vez obtenidos los modelos se exportaron al software de elementos finitos ALGOR con el fin de llevar a cabo el an&aacute;lisis del comportamiento mec&aacute;nico de la estructura dental modelada. El tipo de an&aacute;lisis fue lineal y se consideraron las no linealidades geom&eacute;tricas, se utilizaron elementos hexa&eacute;dricos tipo brick, logrando convergencia de la malla con un modelo con 275.306 nodos y 78.659 elementos.</p>      <p>Las propiedades mec&aacute;nicas de los elementos que componen los modelos num&eacute;ricos fueron obtenidas de la literatura disponible. De esta forma los modelos contaron con propiedades isotr&oacute;picas para: la porcelana, el poste, la gutapercha, la dentina, la resina, la cofi a met&aacute;lica y el ligamento periodontal; y propiedades ortotr&oacute;picas para el poste de fi bra de vidrio, el hueso cortical y esponjoso (v&eacute;ase <a href="#t1">tabla 1</a>).</p>      <p align="center"><a name="t1"><img src=img/revistas/rfoua/v21n2/v21n2a03t1.jpg></a> </p>      <p>Cuando se realiza un corte de una secci&oacute;n del maxilar se obtiene un segmento de tejido &oacute;seo con una superfi cie plana hacia proximal y la otra hacia distal. Para simular la continuidad del maxilar se aplic&oacute; una restricci&oacute;n de todos los grados de libertad en ambas superfi cies que resultan del corte (<a href="#f2">figura 2</a>). Adem&aacute;s se establecieron relaciones de contacto de no penetraci&oacute;n entre las partes que conforman el modelo que est&aacute;n adyacentes entre s&iacute;. Para conocer la distribuci&oacute;n del esfuerzo sobre el diente restaurado, los modelos fueron cargados con una fuerza mon&oacute;tonamente creciente uniformemente distribuida de magnitud 1 N, con una inclinaci&oacute;n de 45&ordm; respecto al eje longitudinal del diente en la cara lingual de la corona. Esta carga simul&oacute; las cargas generadas durante algunos de los movimientos masticatorios.</p>      <p align="center"><a name="f2"><img src=img/revistas/rfoua/v21n2/v21n2a03f2.jpg></a> </p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>RESULTADOS</b></font></p>      <p>En la <a href="#f3">figura 3</a> se muestra la distribuci&oacute;n del esfuerzo de von Mises del tramo de pr&oacute;tesis fija soportado por: postes colados de metal noble (<a href="#f3">figura 3a</a>), postes prefabricados de fi bra de vidrio (<a href="#f3">figura 3b</a>) y los implantes dentales (<a href="#f3">figura 3c</a>).</p>      ]]></body>
<body><![CDATA[<p align="center"><a name="f3"><img src=img/revistas/rfoua/v21n2/v21n2a03f3.jpg></a> </p>      <p>Se observ&oacute; que en el modelo con postes colados, el elemento de retenci&oacute;n (poste) es el que absorbe la mayor cantidad del esfuerzo generado por la carga aplicada sobre la corona al compararlo con el modelo de postes prefabricados que se caracteriz&oacute; por presentar distribuci&oacute;n m&aacute;s uniforme debido a su m&oacute;dulo de elasticidad menor. Debido a este comportamiento, la mayor concentraci&oacute;n del esfuerzo recae sobre los tejidos circundantes (ra&iacute;z y hueso).</p>      <p>En el modelo restaurado con implantes, la concentraci&oacute;n del esfuerzo se present&oacute; en la zona cervical del implante, afectando la parte interna y externa de este, resultado compatible con otros estudios sobre la distribuci&oacute;n de los esfuerzos en los implantes dentales.<sup>28-32</sup></p>      <p>El modelo con postes prefabricados al tener el mismo canal radicular que el modelo con postes colados, presenta el inconveniente que el poste prefabricado no copia perfectamente la geometr&iacute;a del conducto, provocando que el espesor de la pel&iacute;cula de cemento sea mayor, variable que puede haber afectado su comportamiento.<sup>33, 34</sup></p>      <p>La magnitud de los esfuerzos de von Mises se presenta en la <a href="#t2">tabla 2</a>, mediante gr&aacute;ficas.</p>      <p align="center"><a name="t2"><img src=img/revistas/rfoua/v21n2/v21n2a03t2.jpg></a> </p>      <p>En el caso del modelo con implantes dentales, el valor del esfuerzo sobre la ra&iacute;z es asumido como el esfuerzo sobre el implante, ya que este es el sustituto mec&aacute;nico de las ra&iacute;ces en los casos donde est&aacute;n ausentes.</p>      <p>De la <a href="#t2">tabla 2</a> se puede concluir que en los postes colados el esfuerzo mayor es absorbido por la estructura m&aacute;s r&iacute;gida, en cambio en los elementos prefabricados, debido a las propiedades de la fi bra de vidrio, la mayor cantidad del esfuerzo se absorbe por las estructuras adyacentes (dentina, hueso, ligamento).</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      ]]></body>
<body><![CDATA[<p>El an&aacute;lisis de elementos finitos ha sido extensamente utilizado en la odontolog&iacute;a, debido a que permite evaluar el comportamiento mec&aacute;nico de los materiales utilizados para las restauraciones dentales.</p>      <p>El an&aacute;lisis de elementos finitos aplicado en esta investigaci&oacute;n mostr&oacute; cambios en los esfuerzos inducidos en el tramo. Existen diferencias en la distribuci&oacute;n de los esfuerzos en las tres alternativas de retenci&oacute;n de un tramo prot&eacute;sico anterior superior rehabilitado con poste prefabricado (fibra de vidrio), poste colado (metal noble) y un implante dental, estos cambios se explican por tener los materiales restauradores propiedades y geometr&iacute;a diferente.</p>      <p>Los resultados obtenidos sobre los modelos con postes est&aacute;n de acuerdo con lo presentado por Asmussen y colaboradores<sup>11</sup> quienes se plantean que el esfuerzo mayor se da en el poste con un m&oacute;dulo de elasticidad mayor, disminuyendo el esfuerzo en las estructuras adyacentes. La interpretaci&oacute;n de estos resultados es diferente a la de otros autores como Pegoretti y colaboradores,<sup>6</sup> ya que plantean que la distribuci&oacute;n de los esfuerzos en modelos con menor m&oacute;dulo de elasticidad le ofrece una ventaja adicional al diente.</p>      <p>De estos resultados se deduce la importancia de la calidad &oacute;sea y la cantidad cuando la alternativa de restauraci&oacute;n del tramo prot&eacute;sico ser&aacute; implantosoportada, ya que su influencia en el hueso ser&aacute; mayor. Esta interpretaci&oacute;n est&aacute; de acuerdo con el an&aacute;lisis que hacen Geng y colaboradores<sup>35</sup> a la importancia del di&aacute;metro, de la longitud y la cantidad &oacute;sea en implantes dentales y al an&aacute;lisis sobre la deformaci&oacute;n &oacute;sea que hacen Tada y colaboradores.<sup>36</sup></p>      <p>Cuando se compar&oacute; la magnitud del esfuerzo sobre el hueso esponjoso o trabecular, se pudo deducir que la restauraci&oacute;n con implantes gener&oacute; mayor esfuerzo sobre el implante en su periferia y sobre el hueso en la parte cervical, concepto que est&aacute; de acuerdo con el an&aacute;lisis que hace Geng y colaboradores sobre la biomec&aacute;nica en implantes.<sup>35</sup> El modelo con implantes gener&oacute; mayor esfuerzo sobre el hueso que las restauraciones con postes y entre los postes, los prefabricados transmitieron mayor esfuerzo al hueso trabecular que el poste colado. La explicaci&oacute;n de esta diferencia en la distribuci&oacute;n de los esfuerzos entre los modelos de postes y el implante dental se explica por la presencia del ligamento periodontal en el diente, el cual disipa la energ&iacute;a que recibe, debido al bajo m&oacute;dulo de elasticidad del ligamento periodontal. En cambio en el implante dental, por no tener ligamento periodontal y ser un m&oacute;dulo alto (r&iacute;gido), este absorbe la mayor parte de la energ&iacute;a y se transmite al hueso en la zona cervical en mayor porcentaje.</p>      <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>El modelo con implantes dentales gener&oacute; m&aacute;s esfuerzo sobre el hueso en el &aacute;rea cervical que los dientes restaurados con diferentes postes, lo cual se explica por las distintas propiedades del implante y de ra&iacute;z dental.</p>      <p>Entre los postes, los que tienen un mayor m&oacute;dulo de elasticidad, presentan menor esfuerzo sobre la ra&iacute;z y las estructuras adyacentes y los de menor m&oacute;dulo de elasticidad, mayor esfuerzo sobre la ra&iacute;z y los tejidos adyacentes, pero su esfuerzo es m&aacute;s homog&eacute;neo.</p>      <p>Aunque el implante dental genera mayor esfuerzo sobre el hueso, la mayor concentraci&oacute;n se da en el mismo implante.</p>      ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>      <!-- ref --><p>1. Johansson LA, Ekfeld A. Implant-supported fixed partial prostheses: a retrospective study. Int J Prosthodont 2003; 16: 172-176.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0121-246X201000010000300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Stegaroiu R, Sato T, Kusakari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofacial Implants 1998; 13: 82-90.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0121-246X201000010000300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Shillingburg HT, Hobo S, Whitsett L, Jacobi R, Brackett S. Preparation for extensively damaged teeth. In: Fundamentals of fixed prosthodontics. 3.&ordf; ed. Chicago: Quintessence; 1997. p. 181-209.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0121-246X201000010000300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Pierrisnard L, Bohin F, Renault P, Barquins M. Coronoradicular reconstruction of pulpless teeth: a mechanical study using finite element analysis. J Prosthet Dent 2002; 88 (4): 442-448.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0121-246X201000010000300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Holmes DC, D&iacute;az-Arnold AM, Leary JM. Influence of post dimension on stress distribution in dentin. J Prosthet Dent 1996; 75(2): 140-147.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0121-246X201000010000300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Pegoretti A, Fambri L, Zappini G, Bianchtti M. Finite element analysis of a glass fibre reinforced composite endodontic post. J Biomater 2002; 23(13): 2667-2682.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0121-246X201000010000300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Oliver P, Hutter J. Survival rate and fracture strength of incisors restored with different post and core systems and endodontically treated incisors without coronoradicular reinforcement. J Endod 2002; 28(10): 710-775.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0121-246X201000010000300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Heydecke G, Butz F, Strub J. Fracture strength and survival rate of endodontically treated maxillary incisors with approximal cavities after restoration with different post and core systems. An in vitro study. J Dent 2001; 29(6): 427-433.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0121-246X201000010000300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Kogan E. Postes flexibles de fibra de vidrio (t&eacute;cnica directa) para restauraciones de dientes tratados endod&oacute;nticamente. Rev ADM 2001; 58(1): 5-9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0121-246X201000010000300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Akkayan B, G&uuml;lmez T. Resistance to fracture of endodontically treated teeth restored with differents post systems. J Prosthet Dent 2002; 87: 431-437.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0121-246X201000010000300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Asmussen E, Peutzfeldt A, Sahafi A. Finite element analysis of stresses in endodontically treated, dowel-restored teeth. J Prosthet Dent 2005; 94(4): 321-329.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0121-246X201000010000300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Smith CT, Shuman NJ, Wasson W. Biomechanical criteria for evaluating prefabricated post and core systems: a guide for the restorative dentist. Quintessence Int 1998; 29(5): 305-312.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0121-246X201000010000300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Butz F, Lennon M, Heydecke G, Strub J. Survival rate and fracture strength of endodontically treated maxilary incisors with moderate defects restored with different post and core systems: an in vitro study. Int J Prosthodont 2001; 14(1): 58-64.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0121-246X201000010000300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Heydecke G, Butz F, Hussein A, Strub J. Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and core systems. J Prosthet Dent 2002; 87(4): 438-445.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0121-246X201000010000300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Rosentiel SF, Land MF, Fujimoto J. Restoration endodontically treated tooth. In: Contemporary fixed prosthodontics. 4.&ordf; ed. St. Louis: Mosby; 2006. p. 336-378.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0121-246X201000010000300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Genovese K. Finite element analysis of a new customized composite post system for edodontically treated teeth. J Biomech 2005; 38: 2375-2389.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0121-246X201000010000300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Morgano SM. Restoration of pulpless teeth: application of traditional principles in present and future contexts. J Prosthet Dent 1996; 75(4): 375-380.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0121-246X201000010000300017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Tjan H, Whang SB. Resistance to root fracture of dowel channels with various thicknesses of buccal dentin walls. J Prosthet Dent 1985; 53(4): 496-500.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0121-246X201000010000300018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. Baumgartner JC, Falkler WA. Bacterial in the apical 5 mm of infected root canals. J Endod 1991; 17(8): 380-383.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0121-246X201000010000300019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Cohen S, Orenstein J. The use of attachments in combination implant and natural-tooth fixed partial dentures: a technical report. Int J Oral Maxillofac1994; 9(2): 230-234.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0121-246X201000010000300020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Dechow PC, Nail GA, Schwartz-Dabney CL, Ashman RB. Elastic properties of human supraorbital and mandibular bone. Am J Phys Anthropol 1993; 90(3): 291-306.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0121-246X201000010000300021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Turner CH, Cowin SC, Rho JY, Ashman RB, Rice Janet C. The fabric dependence of the orthotropic elastic constantans of cancellous bone. J Biomech 1990; 23(6): 549-561.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0121-246X201000010000300022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23. Reinhardt RA, Krejci RF, Pao YC, Stannard JG. Dentin stresses in post-reconstructed teeth with diminishing bone support. J Dent Res 1983; 62(9): 1002-1008.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X201000010000300023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24. Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent 2003; 89(2): 127-134.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0121-246X201000010000300024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25. Ausiello P, Apicella A, Davidson CL. Effect of adhesive layer properties on stress distribution in composite restorations -a 3D finite element analysis. Den Mater 2002; 18(4): 295-303.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X201000010000300025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Ko CC, Chu CS, Chung KH, Lee MC. Effects of posts on dentin stress distribution in pulpless teeth. J Prosthet Dent 1992; 68(3): 421-427.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0121-246X201000010000300026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>27. Milot P, Stein S. Root fracture in endodontically treated teeth related to post selection and crown design. J Prosthet Dent 1992; 68(3): 428-435.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X201000010000300027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>28. Gunne J, Astrand P, Lindh T. Dentaduras parciales fijas soportadas por dientes-implantes y por implantes: informe de 10 a&ntilde;os. Rev Int Protes Estomatol 2000; 2(1): 39-44.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0121-246X201000010000300028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>29. Gunne J, Rangert B, Glantz PO, Svensson A. Functional loads on freestanding and connected implants in three-unit mandibular prostheses opposing complete dentures: an in vivo study. Int J Oral Maxillofac Implants 1997; 12(3): 335-341.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201000010000300029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30. Palma V, Migu&eacute;lez AM, Parad&iacute;es G. Ferulizaciones dienteimplante. Rev Int Protes Estomatol 2003; 5(2): 131-137.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X201000010000300030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>31. Rangert B, Gunne J, Sullivan D. Mechanical aspects of a Br&aring;nemark implant connected to a natural tooth: an in vitro study. Int J Oral Maxillofac Implants 1991; 6(2): 177-186.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X201000010000300031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>32. Rangert B, Gunne J, Glantz PO, Svensson A. Vertical load distribution on a three unit prosthesis supported by a natural tooth and a single Br&aring;nemark implant. An in vivo study. Clin Oral Implants Res 1995; 6(1): 40-46.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0121-246X201000010000300032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>33. Albuquerque R de C, Abreu Polleto LT. Stress analysis of an upper central incisor restored with different posts. J Oral Rehabil 2003; 30(9): 936-943.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X201000010000300033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>34. Duret B, Duret F, Reynaud M. Long-life physical property preservation and postendodontic rehabilitation with the composipost. Compend Contin Educ Dent 1996; 20 Supl: S50-S56.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0121-246X201000010000300034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>35. Geng PJ, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001; 85(6): 585-598.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X201000010000300035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>36. Tada S, Stegariu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/ strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003; 18(3): 357-368.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0121-246X201000010000300036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>     <p>&nbsp;</p>      ]]></body>
<body><![CDATA[<p><b>RECIBIDO: NOVIEMBRE 4/2008 - ACEPTADO: FEBRERO 23/2010</b></p>       <p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="3" face="Verdana"><b>CORRESPONDENCIA</b></font></p>      <p>Federico Latorre Correa     <br> Facultad de Odontolog&iacute;a     <br> Universidad de Antioquia     <br> Calle 64 N.&ordm; 52-59     <br> Medell&iacute;n, Colombia     <br> Correo electr&oacute;nico:<a href="mailto:flatorre@une.net.co ">flatorre@une.net.co</a></p>       ]]></body>
<body><![CDATA[<p><b>C&oacute;mo citar este art&iacute;culo:</b></p>       <p>Chica E, Latorre F, Agudelo S. Pr&oacute;tesis parcial fija: an&aacute;lisis biomec&aacute;nico sobre distribuci&oacute;n de esfuerzos entre tres alternativas de retenci&oacute;n. Rev Fac Odontol Univ Antioq 2010; 21(2): 150-158.</p>      <p>Chica E, Latorre F, Agudelo S. Fixed partial prosthesis: biomechanical analysis of stress distribution among three retention alternatives. Rev Fac Odontol Univ Antioq 2010; 21(2): 150-158.</p>  </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johansson]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Ekfeld]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implant-supported fixed partial prostheses: a retrospective study]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2003</year>
<volume>16</volume>
<page-range>172-176</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stegaroiu]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Sato]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kusakari]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Miyakawa]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis]]></article-title>
<source><![CDATA[Int J Oral Maxillofacial Implants]]></source>
<year>1998</year>
<volume>13</volume>
<page-range>82-90</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shillingburg]]></surname>
<given-names><![CDATA[HT]]></given-names>
</name>
<name>
<surname><![CDATA[Hobo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Whitsett]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobi]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Brackett]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preparation for extensively damaged teeth]]></article-title>
<source><![CDATA[Fundamentals of fixed prosthodontics]]></source>
<year>1997</year>
<edition>3</edition>
<page-range>181-209</page-range><publisher-loc><![CDATA[Chicago ]]></publisher-loc>
<publisher-name><![CDATA[Quintessence]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pierrisnard]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bohin]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Renault]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Barquins]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronoradicular reconstruction of pulpless teeth: a mechanical study using finite element analysis]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2002</year>
<volume>88</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>442-448</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Díaz-Arnold]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Leary]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of post dimension on stress distribution in dentin]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1996</year>
<volume>75</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>140-147</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pegoretti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fambri]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Zappini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Bianchtti]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of a glass fibre reinforced composite endodontic post]]></article-title>
<source><![CDATA[J Biomater]]></source>
<year>2002</year>
<volume>23</volume>
<numero>13</numero>
<issue>13</issue>
<page-range>2667-2682</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oliver]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hutter]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survival rate and fracture strength of incisors restored with different post and core systems and endodontically treated incisors without coronoradicular reinforcement]]></article-title>
<source><![CDATA[J Endod]]></source>
<year>2002</year>
<volume>28</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>710-775</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heydecke]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Butz]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Strub]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro study]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2001</year>
<volume>29</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>427-433</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kogan]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Postes flexibles de fibra de vidrio (técnica directa) para restauraciones de dientes tratados endodónticamente]]></article-title>
<source><![CDATA[Rev ADM]]></source>
<year>2001</year>
<volume>58</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>5-9</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Akkayan]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Gülmez]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to fracture of endodontically treated teeth restored with differents post systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2002</year>
<volume>87</volume>
<page-range>431-437</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Asmussen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Peutzfeldt]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sahafi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of stresses in endodontically treated, dowel-restored teeth]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2005</year>
<volume>94</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>321-329</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[CT]]></given-names>
</name>
<name>
<surname><![CDATA[Shuman]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wasson]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomechanical criteria for evaluating prefabricated post and core systems: a guide for the restorative dentist]]></article-title>
<source><![CDATA[Quintessence Int]]></source>
<year>1998</year>
<volume>29</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>305-312</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Butz]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Lennon]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Heydecke]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Strub]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survival rate and fracture strength of endodontically treated maxilary incisors with moderate defects restored with different post and core systems: an in vitro study]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2001</year>
<volume>14</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>58-64</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heydecke]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Butz]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Hussein]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Strub]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and core systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2002</year>
<volume>87</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>438-445</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosentiel]]></surname>
<given-names><![CDATA[SF]]></given-names>
</name>
<name>
<surname><![CDATA[Land]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Fujimoto]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Restoration endodontically treated tooth]]></article-title>
<source><![CDATA[Contemporary fixed prosthodontics]]></source>
<year>2006</year>
<edition>4</edition>
<page-range>336-378</page-range><publisher-loc><![CDATA[St. Louis ]]></publisher-loc>
<publisher-name><![CDATA[Mosby]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Genovese]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Finite element analysis of a new customized composite post system for edodontically treated teeth]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>2005</year>
<volume>38</volume>
<page-range>2375-2389</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morgano]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Restoration of pulpless teeth: application of traditional principles in present and future contexts]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1996</year>
<volume>75</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>375-380</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tjan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Whang]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Resistance to root fracture of dowel channels with various thicknesses of buccal dentin walls]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1985</year>
<volume>53</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>496-500</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baumgartner]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Falkler]]></surname>
<given-names><![CDATA[WA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial in the apical 5 mm of infected root canals]]></article-title>
<source><![CDATA[J Endod]]></source>
<year>1991</year>
<volume>17</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>380-383</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Orenstein]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of attachments in combination implant and natural-tooth fixed partial dentures: a technical report]]></article-title>
<source><![CDATA[Int J Oral Maxillofac]]></source>
<year>1994</year>
<volume>9</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>230-234</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dechow]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Nail]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Schwartz-Dabney]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
<name>
<surname><![CDATA[Ashman]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Elastic properties of human supraorbital and mandibular bone]]></article-title>
<source><![CDATA[Am J Phys Anthropol]]></source>
<year>1993</year>
<volume>90</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>291-306</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Turner]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Cowin]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Rho]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
<name>
<surname><![CDATA[Ashman]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Rice]]></surname>
<given-names><![CDATA[Janet]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The fabric dependence of the orthotropic elastic constantans of cancellous bone]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>1990</year>
<volume>23</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>549-561</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reinhardt]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Krejci]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
<name>
<surname><![CDATA[Pao]]></surname>
<given-names><![CDATA[YC]]></given-names>
</name>
<name>
<surname><![CDATA[Stannard]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dentin stresses in post-reconstructed teeth with diminishing bone support]]></article-title>
<source><![CDATA[J Dent Res]]></source>
<year>1983</year>
<volume>62</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1002-1008</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Attar]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Tam]]></surname>
<given-names><![CDATA[LE]]></given-names>
</name>
<name>
<surname><![CDATA[McComb]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical and physical properties of contemporary dental luting agents]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2003</year>
<volume>89</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>127-134</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ausiello]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Apicella]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Davidson]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of adhesive layer properties on stress distribution in composite restorations-a 3D finite element analysis]]></article-title>
<source><![CDATA[Den Mater]]></source>
<year>2002</year>
<volume>18</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>295-303</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ko]]></surname>
<given-names><![CDATA[CC]]></given-names>
</name>
<name>
<surname><![CDATA[Chu]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of posts on dentin stress distribution in pulpless teeth]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1992</year>
<volume>68</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>421-427</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Milot]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Stein]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Root fracture in endodontically treated teeth related to post selection and crown design]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1992</year>
<volume>68</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>428-435</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gunne]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Astrand]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lindh]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dentaduras parciales fijas soportadas por dientes-implantes y por implantes: informe de 10 años]]></article-title>
<source><![CDATA[Rev Int Protes Estomatol]]></source>
<year>2000</year>
<volume>2</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>39-44</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gunne]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rangert]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Glantz]]></surname>
<given-names><![CDATA[PO]]></given-names>
</name>
<name>
<surname><![CDATA[Svensson]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Functional loads on freestanding and connected implants in three-unit mandibular prostheses opposing complete dentures: an in vivo study]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1997</year>
<volume>12</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>335-341</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Palma]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Miguélez]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Paradíes]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ferulizaciones dienteimplante]]></article-title>
<source><![CDATA[Rev Int Protes Estomatol]]></source>
<year>2003</year>
<volume>5</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>131-137</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rangert]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Gunne]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sullivan]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical aspects of a Brånemark implant connected to a natural tooth: an in vitro study]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1991</year>
<volume>6</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>177-186</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rangert]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Gunne]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Glantz]]></surname>
<given-names><![CDATA[PO]]></given-names>
</name>
<name>
<surname><![CDATA[Svensson]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Vertical load distribution on a three unit prosthesis supported by a natural tooth and a single Brånemark implant: An in vivo study]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1995</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>40-46</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albuquerque]]></surname>
<given-names><![CDATA[R de C]]></given-names>
</name>
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[Polleto]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stress analysis of an upper central incisor restored with different posts]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2003</year>
<volume>30</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>936-943</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duret]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Duret]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Reynaud]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-life physical property preservation and postendodontic rehabilitation with the composipost]]></article-title>
<source><![CDATA[Compend Contin Educ Dent]]></source>
<year>1996</year>
<volume>20 Supl</volume>
<page-range>S50-S56</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Geng]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[KBC]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of finite element analysis in implant dentistry: a review of the literature]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2001</year>
<volume>85</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>585-598</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tada]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Stegariu]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kitamura]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Miyakawa]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Kusakari]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of implant design and bone quality on stress/ strain distribution in bone around implants: a 3-dimensional finite element analysis]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2003</year>
<volume>18</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>357-368</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
