<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1909-9762</journal-id>
<journal-title><![CDATA[Revista Ingeniería Biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. ing. biomed.]]></abbrev-journal-title>
<issn>1909-9762</issn>
<publisher>
<publisher-name><![CDATA[Fondo Editorial EIA, Escuela de Ingeniería de Antioquia EIA-, Universidad CES]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1909-97622010000200008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[CIRUGÍA ROBÓTICA MÍNIMAMENTE INVASIVA: ANÁLISIS DE FUERZA Y TORQUE]]></article-title>
<article-title xml:lang="en"><![CDATA[MINIMALLY INVASIVE ROBOTIC SURGERY: FORCE AND TORQUE ANALYSIS]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[Daniel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[Vera Z]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Betancur]]></surname>
<given-names><![CDATA[Manuel J]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[John]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Pontificia Bolivariana Grupo de Investigación en Bioingeniería ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Pontificia Bolivariana Grupo de Dinámica Cardiovascular ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Pontificia Bolivariana Grupo de Dinámica Cardiovascular ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad Pontificia Bolivariana Grupo de Investigación en Automática y Diseño ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2010</year>
</pub-date>
<volume>4</volume>
<numero>8</numero>
<fpage>84</fpage>
<lpage>92</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S1909-97622010000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S1909-97622010000200008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S1909-97622010000200008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La cirugía mínimamente invasiva y la incorporación de la robótica en este tipo de procedimientos representa grandes ventajas para el paciente, el cirujano y los sistemas de salud. Sin embargo, los dispositivos comerciales disponibles en la actualidad no cuentan con realimentación de fuerza y tacto, que faciliten al cirujano la identificación de los tejidos y consecuentemente, la reducción de errores en los procedimientos quirúrgicos; por lo cual, el desarrollo de sistemas que cuenten con este tipo de realimentación se convierte en un tema de interés a nivel mundial. El presente artículo contiene una revisión del estado de la técnica con respecto a los sistemas comerciales y experimentales desarrollados en esta área. También, se presentan algunos sensores y modelos matemáticos utilizados para calcular las fuerzas y torques en cirugía mínimamente invasiva.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Minimally Invasive Surgery and the adaptation of robotics to these procedures represent many advantages for the patient, the surgeon, and the health program. However, commercial devices used nowadays lack haptic feedback. This fact makes the tissue identification more difficult and increments the injuries risk during the surgical procedure. The development of systems with this kind of feedback has become a topic of interest throughout the world. The present article contains a revision of the state of the art about commercial and experimental systems developed in this area. Models for the force and torque propagation, used in Minimally Invasive Surgery, are also presented.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Cirugía robótica mínimamente invasiva]]></kwd>
<kwd lng="es"><![CDATA[Modelos de propagación de fuerza]]></kwd>
<kwd lng="es"><![CDATA[Realimentación de fuerza y torque]]></kwd>
<kwd lng="es"><![CDATA[Sensores de fuerza y torque]]></kwd>
<kwd lng="en"><![CDATA[Minimally invasive robotic surgery]]></kwd>
<kwd lng="en"><![CDATA[Force propagation models]]></kwd>
<kwd lng="en"><![CDATA[Force and torque feedback]]></kwd>
<kwd lng="en"><![CDATA[Force and torque sensors]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">          <p align="center"><font size="4"><b>CIRUG&Iacute;A ROB&Oacute;TICA M&Iacute;NIMAMENTE INVASIVA: AN&Aacute;LISIS DE FUERZA Y TORQUE</b></font></p>     <p align="center"><font size="3"><b>MINIMALLY INVASIVE ROBOTIC  SURGERY: FORCE  AND TORQUE ANALYSIS</b></font></p>     <p>&nbsp;</p>     <p><b>Daniel Ruiz<sup>1</sup>; Vera Z. P&eacute;rez<sup>2,3</sup>; Manuel J. Betancur<sup>4</sup>; John Bustamante<sup>2</sup></b></p>          <p><i>1 Grupo de Investigaci&oacute;n en Bioingenier&iacute;a, Universidad Pontificia Bolivariana, Medell&iacute;n, Colombia.    <br>   2 Grupo de Din&aacute;mica Cardiovascular, Universidad Pontificia Bolivariana, Medell&iacute;n, Colombia.    <br>   3 Direcci&oacute;n para correspondencia: <a href="mailto:vera.perez@upb.edu.co">vera.perez@upb.edu.co</a>.    <br> 4 Grupo de Investigaci&oacute;n en Autom&aacute;tica y Dise&ntilde;o, Universidad Pontificia Bolivariana, Medell&iacute;n, Colombia.</i></p>     <p>Recibido 8 de Noviembre de 2010. Aceptado 8 de Diciembre de 2010</p> <hr size="1" />              ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><b><font size="3">RESUMEN</font></b></p>     <p>La cirug&iacute;a m&iacute;nimamente invasiva y la incorporaci&oacute;n de la rob&oacute;tica en este tipo de procedimientos representa   grandes ventajas para el paciente, el cirujano y los sistemas de salud. Sin embargo, los dispositivos comerciales disponibles   en la actualidad no cuentan con realimentaci&oacute;n de fuerza y tacto, que faciliten al cirujano la identificaci&oacute;n de los tejidos y   consecuentemente, la reducci&oacute;n de errores en los procedimientos quir&uacute;rgicos; por lo cual, el desarrollo de sistemas que cuenten   con este tipo de realimentaci&oacute;n se convierte en un tema de inter&eacute;s a nivel mundial. El presente art&iacute;culo contiene una revisi&oacute;n del   estado de la t&eacute;cnica con respecto a los sistemas comerciales y experimentales desarrollados en esta &aacute;rea. Tambi&eacute;n, se presentan algunos sensores y modelos matem&aacute;ticos utilizados para calcular las fuerzas y torques en cirug&iacute;a m&iacute;nimamente invasiva.</p>          <p><font size="3"><b>PALABRAS CLAVE</b></font>: Cirug&iacute;a rob&oacute;tica m&iacute;nimamente invasiva, Modelos de propagaci&oacute;n de fuerza, Realimentaci&oacute;n de fuerza y  torque, Sensores de fuerza y torque.</p>  <hr size="1" />              <p>&nbsp;</p>     <p><font size="3"><b>ABSTRACT</b></font></p>     <p>Minimally Invasive Surgery and the adaptation of robotics to these procedures represent many advantages for the   patient, the surgeon, and the health program. However, commercial devices used nowadays lack haptic feedback. This fact makes   the tissue identification more difficult and increments the injuries risk during the surgical procedure. The development of systems   with this kind of feedback has become a topic of interest throughout the world. The present article contains a revision of the state   of the art about commercial and experimental systems developed in this area. Models for the force and torque propagation, used in Minimally Invasive Surgery, are also presented.</p>     <p><font size="3"><b>KEY WORDS</b></font>: Minimally invasive robotic surgery, Force propagation models, Force and torque feedback, Force and torque sensors.</p>  <hr size="1" />           <p>&nbsp;</p>       <p><font size="3"><b>I. INTRODUCCI&Oacute;N</b></font></p>          ]]></body>
<body><![CDATA[<p>El tema de la cirug&iacute;a m&iacute;nimamente invasiva (MIS:   <i>Minimally Invasive Surgery</i>) toma cada d&iacute;a m&aacute;s   fuerza en la comunidad cient&iacute;fica internacional. Los   estudios comparativos muestran sus ventajas frente a   la cirug&iacute;a tradicional, proporcionando la posibilidad   de complementar esta t&eacute;cnica mediante la adopci&oacute;n de   sistemas rob&oacute;ticos que potencializan las habilidades   del cirujano, a trav&eacute;s de la denominada cirug&iacute;a rob&oacute;tica   m&iacute;nimamente invasiva (<i>MIRS</i>: <i>Minimally Invasive   Robotic Surgery</i>). Es importante anotar, sin embargo, que   ni el procedimiento tradicional de MIS, ni los desarrollos   comerciales actuales en <i>MIRS</i>, cuentan con realimentaci&oacute;n   de tacto y fuerza, por lo cual, la necesidad de desarrollar   dispositivos que reproduzcan sensaciones t&aacute;ctiles,   m&aacute;s conocidos como dispositivos haptics o h&aacute;ptica, se encuentra dentro de los objetivos de las investigaciones de   punta en el &aacute;mbito mundial &#91;<a href="#1">1</a>&#93;.</p>     <p>Este trabajo presenta una revisi&oacute;n del estado de la   t&eacute;cnica y describe diferentes sistemas rob&oacute;ticos y aspectos   relacionados con la inclusi&oacute;n de la realimentaci&oacute;n de   fuerza en este tipo de dispositivos. En la organizaci&oacute;n del   art&iacute;culo, la secci&oacute;n II presenta una descripci&oacute;n de la MIS,   los instrumentos utilizados y sus aplicaciones m&aacute;s comunes.   Seguidamente, describe la <i>MIRS</i> y puntualiza la importancia   de la medici&oacute;n de fuerza y torque (F/T) en este tipo de   intervenci&oacute;n quir&uacute;rgica. La secci&oacute;n III presenta dispositivos   comerciales y proyectos de desarrollo relacionados con   <i>MIRS</i>, haciendo alusi&oacute;n a los sensores F/T utilizados en   estos. La secci&oacute;n IV presenta algunos modelos matem&aacute;ticos   utilizados para relacionar la fuerza aplicada por el cirujano   con la fuerza aplicada sobre el &oacute;rgano o tejido.</p>     <p>&nbsp;</p>     <p><b><font size="3">II. GENERALIDADES DE LA MIS</font></b></p>     <p>La <i>MIS</i> es una t&eacute;cnica alternativa a la cirug&iacute;a invasiva   convencional que permite llevar a cabo procedimientos   quir&uacute;rgicos sin necesidad de realizar una gran incisi&oacute;n,   disminuyendo de esta manera las lesiones en el paciente   y reduciendo el riesgo de hemorragias &#91;<a href="#2">2</a>&#93;. Lo anterior   se ve reflejado en un procedimiento menos cruento   con una mejor calidad de vida en el postoperatorio,   acortamiento del tiempo de recuperaci&oacute;n y menores   costos hospitalarios &#91;<a href="#3">3</a>-<a href="#6">6</a>&#93;.</p>     <p>Las aplicaciones de la <i>MIS</i> van desde la cirug&iacute;a general   para adultos &#91;<a href="#3">3</a>, <a href="#7">7</a>&#93; hasta las pedi&aacute;tricas, pasando por   aplicaciones cardiotor&aacute;cicas &#91;<a href="#8">8</a>-<a href="#10">10</a>&#93;, laparosc&oacute;picas &#91;<a href="#11">11</a>,   <a href="#12">12</a>&#93;, urol&oacute;gicas &#91;<a href="#13">13</a>&#93;, neurol&oacute;gicas &#91;<a href="#14">14</a>&#93; y artrosc&oacute;picas.</p>     <p>El instrumental quir&uacute;rgico utilizado en <i>MIS</i> se puede   dividir en tres tipos: instrumental de acceso, instrumental   de visualizaci&oacute;n e instrumental de disecci&oacute;n; aunque   pueden existir variaciones en el instrumental seg&uacute;n el   procedimiento quir&uacute;rgico &#91;<a href="#15">15</a>&#93;.</p>     <p>El instrumental de acceso incluye las herramientas   relacionadas con la creaci&oacute;n de un espacio de trabajo o   campo quir&uacute;rgico, en el cual se lleva a cabo la MIS, (<a href="#fig1">Fig.   1</a>). En el caso de la cirug&iacute;a laparosc&oacute;pica, los instrumentos   m&aacute;s conocidos para accesar la cavidad abdominal son:   la aguja de Veress, usada para puncionar el abdomen e   insuflar con gas inerte; los tr&oacute;cares, que son elementos a   trav&eacute;s de los cuales se introduce el laparoscopio y dem&aacute;s   instrumentos; y reductores-adaptadores que se utilizan   para evitar fugas de gas al introducir instrumental de   menor di&aacute;metro que el tr&oacute;car utilizado.</p>       <p align="center"><a name="fig1"></a><img src="img/revistas/rinbi/v4n8/v4n8a08fig1.gif"></p>     <p>La instrumentaci&oacute;n &oacute;ptica est&aacute; constituida por un   endoscopio o tubo que cuenta con un sistema especial   de lentes, que a trav&eacute;s de fibra &oacute;ptica transmite la luz   generada por una fuente externa para iluminar la cavidad   de trabajo. Este sistema se conecta a una c&aacute;mara de video,   que lleva la imagen hasta los monitores. En las t&eacute;cnicas de   <i>MIRS</i> m&aacute;s avanzadas se utilizan dos c&aacute;maras de video para   obtener una imagen tridimensional del interior del paciente   y de esta forma se mejorar la realimentaci&oacute;n visual.</p>     ]]></body>
<body><![CDATA[<p>El instrumental de disecci&oacute;n se usa para realizar   la cirug&iacute;a o acto quir&uacute;rgico en s&iacute;. Comprende diversas   pinzas usadas para la tracci&oacute;n de tejidos y la disecci&oacute;n, as&iacute;   como tambi&eacute;n fuentes de corriente el&eacute;ctrica, monopolar   y bipolar, utilizadas para la coagulaci&oacute;n y para cortar los   tejidos, (<a href="#fig1">Fig. 1</a>).</p>     <p>Aunque son muchas las ventajas que la <i>MIS</i> tiene sobre   la cirug&iacute;a convencional, esta presenta algunas dificultades   para los cirujanos, quienes se ven obligados a interactuar   en el campo quir&uacute;rgico con reducidos grados de libertad   y limitado sentido del tacto &#91;<a href="#16">16</a>&#93;; y a su vez, disponiendo   s&oacute;lo de realimentaci&oacute;n visual en dos dimensiones, lo cual   implica una coordinaci&oacute;n manual-visual diferente a la   habitual del cirujano &#91;<a href="#17">17</a>&#93;.</p>     <p>Con el objetivo de facilitar el trabajo del cirujano,   disminuyendo problemas como el temblor debido a   la fatiga muscular y mejorando la precisi&oacute;n en los   procedimientos, se recurre a la <i>MIRS</i> &#91;<a href="#18">18</a>&#93;, en la que se   implementa una plataforma de rob&oacute;tica compuesta por dos   elementos definidos como maestro y esclavo (<a href="#fig2">Fig. 2</a>).</p>       <p align="center"><a name="fig2"></a><img src="img/revistas/rinbi/v4n8/v4n8a08fig2.gif"></p>     <p>El sistema maestro consiste en una interfaz hombrem&aacute;quina,   que recibe los comandos del cirujano, los adapta   y los transmite a un sistema ejecutor. As&iacute;, el maestro es   una estaci&oacute;n de trabajo con la que el cirujano interact&uacute;a   para comandar la cirug&iacute;a.</p>     <p>El sistema esclavo es un robot dotado con tres o cuatro   brazos. Generalmente se utiliza uno de ellos para controlar   la c&aacute;mara y los otros para manipular el instrumental   quir&uacute;rgico. En s&iacute;ntesis, en el esclavo, se ejecutan las &oacute;rdenes   de movimiento que se reciben del sistema maestro.</p>     <p>Si bien con la <i>MIRS</i> se mejora el desempe&ntilde;o de la   <i>MIS</i> &#91;<a href="#19">19</a>&#93;, es claro que los cirujanos dependen del sentido   del tacto para diferenciar caracter&iacute;sticas como la rigidez   o elasticidad, la dureza o la fragilidad de los &oacute;rganos y   tejidos. Con las t&eacute;cnicas empleadas en <i>MIS</i> y en <i>MIRS</i>, que   carecen de estas sensaciones h&aacute;pticas, se ve disminuida   la habilidad de los cirujanos y, en ocasiones, predispone a   lesiones iatrog&eacute;nicas durante el procedimiento quir&uacute;rgico   &#91;<a href="#20">20</a>&#93;. Por lo tanto, un sistema que permita entregar al   cirujano realimentaci&oacute;n t&aacute;ctil mejorar&iacute;a los resultados   de dichas intervenciones, ya que disminuir&iacute;a las lesiones   accidentales causadas por la falta del sentido del tacto &#91;<a href="#21">21</a>&#93;.</p>     <p>Los dispositivos com&uacute;nmente utilizados para sensar las   magnitudes relacionadas con h&aacute;ptica son los denominados   sensores F/T &#91;<a href="#22">22</a>, <a href="#23">23</a>&#93;. Una revisi&oacute;n de la actualidad en este   tipo de sensores y modelos asociados es de utilidad para   el desarrollo de proyectos enfocados al mejoramiento de la   realimentaci&oacute;n t&aacute;ctil en <i>MIRS</i>.</p>     <p>&nbsp;</p>     <p><b><font size="3">III. DESARROLLOS COMERCIALES Y EXPERIMENTALES EN MIRS</font></b></p>     ]]></body>
<body><![CDATA[<p>Desde principios de la d&eacute;cada de los 90 se han   desarrollado m&aacute;s de 35 sistemas rob&oacute;ticos para aplicaciones   en <i>MIRS</i>, entre sistemas comerciales y experimentales   &#91;<a href="#24">24</a>&#93;. Seguidamente, se presentan sistemas comerciales y   en desarrollo, orientados a la realimentaci&oacute;n F/T, cuyos   resultados son potencialmente &uacute;tiles en <i>MIRS</i>.</p>     <p><i><font size="3">3.1. Desarrollos comerciales:</font></i></p>     <p>Los siguientes dispositivos, algunos no disponibles   actualmente en el mercado, han facilitado las labores del   cirujano potencializando sus habilidades quir&uacute;rgicas:</p>     <p><i><b>AESOP<sup>TM</sup></b></i> (<i>Sistema Endosc&oacute;pico Automatizado para   Posicionamiento &Oacute;ptimo</i>): es un dispositivo rob&oacute;tico que   sostiene el laparoscopio en una cirug&iacute;a y responde a los   comandos remotos del cirujano. Fue el primer sistema   comercialmente disponible para guiar el endoscopio   que fue aprobado por la FDA, en 1994, fabricado por la   empresa <i>Computer Motion Inc</i>. El brazo se fija a la mesa   de cirug&iacute;a, lo que facilita cambiar de ambiente operativo,   sin necesidad de reposicionar el equipo. Inicialmente, era   controlado por el cirujano a trav&eacute;s de un pedal o control   manual, y en versiones posteriores, se ha incorporado   tarjetas de sonido para pregrabar comandos de voz &#91;<a href="#5">5</a>,   <a href="#7">7</a>, <a href="#25">25</a>, <a href="#26">26</a>&#93;. De esta manera el cirujano, por medio de un   micr&oacute;fono, emite &oacute;rdenes que el sistema reconoce para   controlar la c&aacute;mara, la luz para la c&aacute;mara, la impresora   digital, la grabadora de video o la presi&oacute;n del gas &#91;<a href="#5">5</a>&#93;. El   sistema de control cumple funciones importantes: evita   el temblor, presenta estabilidad en los movimientos de la   imagen, se desplaza en diferentes direcciones de acuerdo a   los comandos del cirujano y guarda en memoria posiciones   prefijadas para que el cirujano retorne a ellas cuando lo   considere necesario.</p>     <p><b><i>ENDOASSIST<sup>TM</sup></i></b>: es un mecanismo que cuenta con   un emisor y un receptor de infrarrojo fabricado por la   compa&ntilde;&iacute;a <i>Armstrong-Healthcare</i>, hoy llamada <i>Prosurgics</i>.   El emisor es colocado en la cabeza del cirujano por medio   de una cinta, y de esta manera &eacute;ste decide a qu&eacute; punto del   espacio enfocar la c&aacute;mara laparosc&oacute;pica. Despu&eacute;s que   haya seleccionado el sitio, activa el mecanismo con un   pedal &#91;<a href="#27">27</a>&#93;.</p>     <p><b><i>ZEUS<sup>TM</sup></i></b>: es un dispositivo rob&oacute;tico desarrollado   por <i>Motion Computer Incorporated</i>, la misma empresa   que desarroll&oacute; AESOP. Est&aacute; conformado por tres   brazos: uno de ellos es el endoscopio AESOP y los otros   dos son manipuladores del instrumental quir&uacute;rgico.   El sistema brinda opciones de visualizaci&oacute;n en dos   y tres dimensiones. Sin embargo, Zeus tiene algunas   debilidades como el hecho que sus brazos trabajan   independientemente y no existe un sistema de referencia   en el espacio tridimensional para el sistema integrado &#91;<a href="#28">28</a>&#93;.</p>     <p><b><i>DaVinci<sup>TM</sup></i></b>: es uno de los pocos sistemas rob&oacute;ticos   quir&uacute;rgicos avanzados que est&aacute; siendo comercializado   en este momento, puesto que desde el a&ntilde;o 2003 <i>Intuitive   Surgical Inc</i>., la empresa que comercializa este sistema,   adquiri&oacute; a <i>Computer Motion Inc</i>. y suspendi&oacute; la   producci&oacute;n del sistema Zeus. El sistema daVinci cuenta   con tres partes fundamentales: (1) la consola como interfaz entre el cirujano y el robot; (2) la torre laparosc&oacute;pica con   un monitor para la visualizaci&oacute;n del procedimiento, fuente   de luz, control de las c&aacute;maras, electrobistur&iacute; e insuflador;   y (3) el robot situado al lado del paciente, que posee tres   brazos fijos y uno opcional para algunos procedimientos.</p>     <p>Aunque algunos de estos sistemas comerciales poseen   ventajas tales como visualizaci&oacute;n en 3D y terminales de   operaci&oacute;n ergon&oacute;micas, a&uacute;n no cuentan con sensaci&oacute;n   h&aacute;ptica.</p>     <p><i><font size="3">3.2. Desarrollos experimentales:</font></i></p>     <p>Se presentan algunos desarrollos experimentales   orientados a la realimentaci&oacute;n h&aacute;ptica cuyos resultados   son potencialmente &uacute;tiles en <i>MIRS</i>:</p>     ]]></body>
<body><![CDATA[<p>El sistema de telepresencia para tareas de microcirug&iacute;a,   desarrollado en el <i>Korea Advanced Institute Of Science   And Technology</i> (KAIST) es capaz de entregar reflexi&oacute;n   de fuerza y torque en seis grados de libertad a la consola   del maestro. El esclavo consiste en un robot industrial   tipo paralelo de seis grados de libertad modificado para   posicionar una plataforma para micromanipulaci&oacute;n. Este   sistema no ofrece una manipulaci&oacute;n completa en los   seis grados de libertad, sin embargo, es uno de los pocos   sistemas experimentales que proveen realimentaci&oacute;n t&aacute;ctil.</p>     <p>El sistema <i>Computarized Force Feedback Endoscopic   Grasper</i> (FREG), que utiliza instrumental laparosc&oacute;pico   sin modificaciones, permite manipular la fuerza de   agarre de los instrumentos ya sea por medio de hardware   teleoperado desde el maestro o por medio de software   &#91;<a href="#29">29</a>&#93;. Los experimentos realizados demostraron la   capacidad que brinda este sistema para diferenciar &oacute;rganos   y tejidos, sin embargo, su desempe&ntilde;o a&uacute;n es inferior al   tacto humano. El instrumento no est&aacute; fijo a ning&uacute;n robot y   s&oacute;lo permite un grado de libertad para abrir y cerrar.</p>     <p>El programa <i>Rob&oacute;tica, Sensado Inteligente y   Mecatr&oacute;nica</i> (PRISM) de la Universidad de Drexel,   EE.UU., desarroll&oacute; un sistema en el que herramientas   laparosc&oacute;picas equipadas con celdas de carga transmiten   informaci&oacute;n a un PHANToM, que es un dispositivo   h&aacute;ptico de aplicaci&oacute;n general &#91;<a href="#30">30</a>&#93;. Dado que la   herramienta laparosc&oacute;pica no est&aacute; adaptada a un robot,   el sistema requiere de dos personas para su operaci&oacute;n:   una para manipular el instrumento y otra para sensar las   fuerzas en la interfaz h&aacute;ptica.</p>     <p>El mismo grupo de trabajo desarroll&oacute; un sistema capaz   de realizar la realimentaci&oacute;n t&aacute;ctil por medio de un sistema   visual en el que se utiliza un robot industrial (Mitsubishi   PA-10), equipado con una membrana deformable &#91;<a href="#31">31</a>&#93;.   La deformaci&oacute;n es seguida por c&aacute;maras en est&eacute;reo y   mediante la medici&oacute;n del desplazamiento se calcula la   fuerza de contacto aparente. El sistema est&aacute; limitado a una   realimentaci&oacute;n de fuerza con una frecuencia m&aacute;xima de   30 Hz, debido a la velocidad de muestreo de las c&aacute;maras.   A&uacute;n no se demuestra la robustez de este m&eacute;todo en   aplicaciones con seres vivos.</p>     <p>En el trabajo de Tavakoli <i>et al</i>. &#91;<a href="#32">32</a>&#93; se describe un   sistema maestro-esclavo capaz de reflejar las fuerzas del   esclavo hacia el maestro. Este prototipo usa dos sistemas   PHANToM, uno en el maestro y otro en el esclavo, y   utiliza sensores de fuerza y torque ubicados en el extremo   proximal a la mano del cirujano, por lo que las mediciones   se ven distorsionadas por la interacci&oacute;n del tr&oacute;car y del   instrumental quir&uacute;rgico.</p>     <p>En el trabajo de Seibold <i>et al</i>. &#91;<a href="#33">33</a>&#93; se describe   una pinza con actuadores que cuenta con seis grados   de libertad. Para esto, se utiliza un micro-sensor, no   comercial, que se ubica cerca del efector final. El sistema   est&aacute; compuesto por dos elementos, uno dise&ntilde;ado para   estar en contacto con el paciente, por lo que no contiene   partes el&eacute;ctricas y se puede esterilizar con los sistemas   convencionales, mientras que el otro contiene los   componentes electr&oacute;nicos y los motores, por lo que s&oacute;lo se   puede esterilizar superficialmente. Este sistema a&uacute;n no se   ha integrado a un equipo de telecirug&iacute;a.</p>     <p>El <i>Institute of Robotics and Mechatronics at the   German Aerospace Center</i> (DLR) desarroll&oacute; un sistema   de telecirug&iacute;a con realimentaci&oacute;n de fuerza &#91;<a href="#34">34</a>&#93;. En el   maestro, un PHANToM sirve como interfaz de entrada   y una c&aacute;mara est&eacute;reo presenta las im&aacute;genes al cirujano.   El esclavo est&aacute; compuesto por dos robots de cirug&iacute;a   comerciales, el AESOP<sup>TM</sup> 1000 DS y el AESOP<sup>TM</sup> 3000   DS. El primero est&aacute; equipado con un laparoscopio r&iacute;gido y   entrega una imagen tridimensional del sitio de operaci&oacute;n.   El segundo est&aacute; equipado con un sensor de seis grados de   libertad en la parte distal del instrumento para captar las   magnitudes y as&iacute; proveer la realimentaci&oacute;n t&aacute;ctil.</p>     <p>En el trabajo de Tholey <i>et al</i>. &#91;<a href="#35">35</a>&#93; se presenta un   prototipo de pinza en la cual se utiliza un sensor integrado   a la misma, para medir tanto la fuerza de agarre como las   fuerzas longitudinales en el interior de &eacute;sta. Se utiliza una   celda de carga externa para comparar el desempe&ntilde;o del   instrumento. Este instrumento a&uacute;n no se ha integrado a un   sistema rob&oacute;tico de telecirug&iacute;a.</p>     <p>El robot MC2E desarrollado por el <i>Laboratoire de   Robotique</i> de Paris es un robot compacto dise&ntilde;ado para   medir las fuerzas de interacci&oacute;n entre los &oacute;rganos y   los instrumentos laparosc&oacute;picos. A diferencia de otros   sistemas rob&oacute;ticos usados en <i>MIRS</i>, que usan microsensores   localizados en un extremo de los instrumentos,   este dispositivo utiliza un sensor F/T situado en el exterior   del paciente, en un tr&oacute;car modificado, por lo que se   reducen las limitantes de tama&ntilde;o y esterilidad, haciendo el sistema m&aacute;s econ&oacute;mico. El sistema est&aacute; compuesto por   dos robots, uno que se sit&uacute;a sobre la piel del paciente y se   fija al tr&oacute;car, que es el encargado de orientar el tr&oacute;car para   situar el instrumento en la posici&oacute;n deseada, y otro robot   que se encarga de hacer girar la orientaci&oacute;n de la punta   del instrumento y de introducirla o retirarla seg&uacute;n sea   necesario &#91;<a href="#36">36</a>&#93;.</p>     <p>Algunos grupos de investigaci&oacute;n &#91;37, 38&#93; se han   enfocado en mejorar el rendimiento de las <i>MIRS</i> por medio de la inclusi&oacute;n de sensores de fuerza   y torque en herramientas convencionales de MIS,   para estudiar las fuerzas ejercidas sobre los tejidos   u &oacute;rganos; sin embargo, estos desarrollos a&uacute;n no   cuentan con la suficiente validaci&oacute;n para poder ser   implementados, ya que los sensores desarrollados no   son lo suficientemente peque&ntilde;os o no son reusables o   esterilizables.</p>     ]]></body>
<body><![CDATA[<p>Un compendio de los sensores F/T utilizados en los   proyectos de investigaci&oacute;n mencionados anteriormente y   las caracter&iacute;sticas m&aacute;s relevantes se presenta en la <a href="#tab1">Tabla 1</a>.</p>       <p align="center"><a name="tab1"></a><a href="img/revistas/rinbi/v4n8/v4n8a08tab1.gif" target="_blank">Tabla 1</a></p>     <p><i>Sistema rob&oacute;tico Robin Heart</i>. Es un sistema   teleoperado dise&ntilde;ado para aplicaciones en cirug&iacute;a   card&iacute;aca y con posibilidad de expandir su funcionalidad   a otros procedimientos &#91;<a href="#39">39</a>-<a href="#44">44</a>&#93;. Est&aacute; compuesto por:   (1) un maestro que contiene cuatro uniones, tres   rotacionales y una prism&aacute;tica. En cada una de las   uniones se tienen codificadores &oacute;pticos para captar   los movimientos de la mano del cirujano &#91;<a href="#45">45</a>&#93;, (2) un   esclavo que posee un brazo para sostener la c&aacute;mara y   otros dos equipados con el instrumental quir&uacute;rgico, y   (3) un sistema de control implementado en un <i>Digital   Signal Processor</i> (DSP), el cual se encarga de traducir   los comandos del sistema maestro a movimientos en el   sistema esclavo estableciendo escalas para transformar   los movimientos maestro-esclavo, entregando adecuada   precisi&oacute;n, exactitud y resoluci&oacute;n para realizar cirug&iacute;as, y   eliminando el temblor en los movimientos del cirujano.</p>     <p>En la actualidad <i>Robin Heart</i> cuenta solamente con   realimentaci&oacute;n visual. Se pretende incluir en este sistema   la realimentaci&oacute;n de las variables fuerza y torque &#91;<a href="#46">46</a>, <a href="#47">47</a>&#93;,   por lo cual un an&aacute;lisis de los modelos de propagaci&oacute;n de   dichas variables en el instrumental quir&uacute;rgico endosc&oacute;pico   y una revisi&oacute;n de las alternativas para la localizaci&oacute;n de   los sensores, es de utilidad para el desarrollo de proyectos   enfocados al mejoramiento de la realimentaci&oacute;n t&aacute;ctil en   este dispositivo.</p>       <p>&nbsp;</p>     <p><b><font size="3">IV. SENSORES Y MODELOS DE PROPAGACI&Oacute;N DE FUERZAS EN  INSTRUMENTAL QUIR&Uacute;RGICO ENDOSC&Oacute;PICO</font></b></p>     <p>Mientras que los sistemas con realimentaci&oacute;n   visual para aplicaci&oacute;n en <i>MIRS</i> utilizan las variables   de movimiento (posici&oacute;n, velocidad, aceleraci&oacute;n), los   sistemas h&aacute;pticos incorporan la medici&oacute;n de las variables   fuerza y torque; por lo cual se presenta en esta revisi&oacute;n   del estado de la t&eacute;cnica, algunos modelos de propagaci&oacute;n   de fuerzas en los que se relacionan las variables de   movimiento con las variables de fuerza y torque, y los   cuales determinan la forma en que &eacute;stas interact&uacute;an &#91;<a href="#48">48</a>&#93;.</p>     <p>A pesar de la existencia de numerosos trabajos   alrededor de la implementaci&oacute;n h&aacute;ptica en <i>MIRS</i>, a&uacute;n no   se cuenta a nivel comercial con un sistema validado que   tenga esta caracter&iacute;stica. Los sistemas que se presentan a   continuaci&oacute;n son un abordaje experimental teniendo en   cuenta que en <i>MIRS</i> existen dos tipos de interacciones   con los tejidos, en los que se requiere medir fuerza y   torque: los relacionados con los movimientos en la punta   del instrumental descritos por el modelo matem&aacute;tico de   la secci&oacute;n 4.1 y los relacionados con el posicionamiento   y la interacci&oacute;n del instrumental con los &oacute;rganos o tejidos   en la cavidad descritos por el modelo matem&aacute;tico en la   secci&oacute;n 4.2.</p>     <p>Los sensores F/T m&aacute;s usados en la <i>MIRS</i> toman   medidas en 6 ejes (Fx, Fy, Fz, Mx, My y Mz), aunque   tambi&eacute;n se utilizan algunos que &uacute;nicamente toman   medidas en 3 ejes (Fx, Fy y Fz). Existen tres posiciones   posibles para la implantaci&oacute;n de los sensores F/T: cerca   de la empu&ntilde;adura, en el tr&oacute;car y en la punta. Cada una de   estas ubicaciones tiene sus ventajas y desventajas.</p>     <p>Posicionamiento cerca de la empu&ntilde;adura del   instrumental: se pueden utilizar sensores comerciales   con menores restricciones de tama&ntilde;o y esterilizaci&oacute;n   que en la punta del mismo. Esto implica menores costos   de implementaci&oacute;n por las modi&#64257;caciones menores que   debe hacerse al instrumental quir&uacute;rgico, sin embargo,   las mediciones en esta posici&oacute;n se ven afectadas por la   fricci&oacute;n entre el instrumental y el tr&oacute;car.</p>     ]]></body>
<body><![CDATA[<p>Posicionamiento en el tr&oacute;car: no se requiere hacer   modi&#64257;caciones en el instrumental quir&uacute;rgico y se tienen   las mismas ventajas respecto a las pocas restricciones en el   tama&ntilde;o del sensor y requerimientos de esterilizaci&oacute;n que al   colocar el sensor cerca de la empu&ntilde;adura. Adicionalmente,   las mediciones en este punto s&oacute;lo se ven afectadas por la   fuerza de gravedad, lo cual se puede compensar por medio   de algoritmos de control; sin embargo, se necesita usar un   tr&oacute;car modi&#64257;cado, incrementando los costos.</p>     <p>Posicionamiento en la punta de la herramienta: se   obtiene la medici&oacute;n m&aacute;s directa de fuerza y torque,   sin embargo, se requiere de sensores F/T de peque&ntilde;as   dimensiones y f&aacute;cil esterilizaci&oacute;n, que en la actualidad a&uacute;n   est&aacute;n en desarrollo y tienen un costo elevado. Requiere   instrumentos especiales con los sensores incorporados por   lo que su implementaci&oacute;n es m&aacute;s costosa. A continuaci&oacute;n   se presentan algunos modelos matem&aacute;ticos desarrollados   para aplicaciones en <i>MIRS</i>.</p>     <p><i><font size="3">4.1. Modelo de propagaci&oacute;n de fuerzas en el interior del   instrumento:</font></i></p>     <p>El modelo matem&aacute;tico que se presenta en el trabajo   de Payandeh &#91;<a href="#49">49</a>&#93; representa el caso de un sistema   general que involucra dispositivos de pinza o aguja.   Este modelo de propagaci&oacute;n de fuerzas representa una   pinza laparosc&oacute;pica como un sistema que incorpora   un mecanismo de cuatro barras con dos puntos fijos. A   trav&eacute;s del an&aacute;lisis matem&aacute;tico se plantea relaciones entre   el desplazamiento lineal horizontal del mecanismo y su   &aacute;ngulo de apertura. Utilizando los par&aacute;metros cinem&aacute;ticos   del sistema se define la relaci&oacute;n entre la fuerza aplicada   por el cirujano y la fuerza que llega al mecanismo de   cuatro barras. La fuerza que llega al mecanismo de cuatro   barras se representa por la expresi&oacute;n:</p>       <p align="center"><img src="img/revistas/rinbi/v4n8/v4n8a08for1.gif"></p>     <p>siendo <i>F<sub>h</sub></i> la fuerza que llega al mecanismo de cuatro   barras, <i>F<sub>p</sub></i> la fuerza aplicada por el cirujano, <i>L<sub>3</sub></i> y <i>L<sub>4</sub></i> la   longitud de las barras donde se aplica la fuerza <i>F<sub>p</sub></i>, siendo <i>L<sub>3</sub></i> la   barra menor longitud y <i>L<sub>4</sub></i> la barra de mayor longitud, (<a href="#fig3">Fig. 3</a>).   Adicionalmente, el modelo presenta la relaci&oacute;n entre   la fuerza en la punta de la herramienta <i>F<sub>g</sub></i> como funci&oacute;n   de la fuerza <i>F<sub>p</sub></i> y el desplazamiento del mecanismo. Este   modelo matem&aacute;tico est&aacute; validado por el trabajo de Gupta   &#91;<a href="#50">50</a>&#93;, en el cual se compararon las fuerzas en la punta de   la herramienta ejercidas en <i>MIS</i> y en cirug&iacute;a convencional.   En los resultados experimentales de este estudio se   aprecia, al igual que en el trabajo de Payandeh &#91;<a href="#49">49</a>&#93;, la no   linealidad existente entre la <i>F<sub>p</sub></i> de entrada y la <i>F<sub>g</sub></i> ejercida   sobre los &oacute;rganos y tejidos.</p>     <p align="center"><a name="fig3"></a><a href="img/revistas/rinbi/v4n8/v4n8a08fig3.gif" target="_blank">Figura 3</a></p>     <p><i><font size="3">4.2. Modelo de propagaci&oacute;n de fuerzas en el exterior del   instrumento:</font></i></p>     <p>La mayor&iacute;a de los autores consideran el instrumento   para procedimientos endosc&oacute;picos como una barra r&iacute;gida   que no se deforma ni se comprime y sobre la cual son   despreciables los efectos como la fricci&oacute;n con el tr&oacute;car   y la fuerza de gravedad, sin embargo, Zemiti <i>et al</i>. &#91;<a href="#36">36</a>&#93;   presentan un modelo matem&aacute;tico detallado para el caso   del robot MC2E. Este modelo plantea unas ecuaciones   din&aacute;micas del instrumento que permiten medir la   interacci&oacute;n de las fuerzas entre la punta de este y los tejidos, sin tener en cuenta la fricci&oacute;n con el tr&oacute;car; esto,   gracias a la configuraci&oacute;n especial del robot MC2E.</p>     <p>Del an&aacute;lisis din&aacute;mico del instrumento se obtiene la   expresi&oacute;n:</p>       ]]></body>
<body><![CDATA[<p align="center"><a name="for2"></a><img src="img/revistas/rinbi/v4n8/v4n8a08for2.gif"></p>     <p>donde w<sub>2->1</sub> es el torque aplicado por un actuador de   desplazamiento sobre el instrumento, w<sub>3->1</sub> representa el   torque debido a la interacci&oacute;n entre el instrumento y la   gu&iacute;a pasiva que se instala en el tr&oacute;car modificado, incluye   los efectos de la fricci&oacute;n debido al desplazamiento a lo   largo del eje de penetraci&oacute;n y los sellos en el tr&oacute;car, w<sub>7->1</sub>   representa la fuerza que ejerce el &oacute;rgano o tejido sobre el   instrumento, w<sub>gl</sub> es el torque aplicado sobre el instrumento   debido a la fuerza de gravedad, y w<sub>dl</sub> es el torque din&aacute;mico   de la inercia del instrumento debido a su aceleraci&oacute;n;   w<sub>1->7</sub> el torque que ejerce el instrumento sobre el &oacute;rgano   o tejido, es el de mayor inter&eacute;s ya que permitir&iacute;a una   interacci&oacute;n segura con los &oacute;rganos, (<a href="#fig4">Fig. 4</a>).</p>       <p align="center"><a name="fig4"></a><a href="img/revistas/rinbi/v4n8/v4n8a08fig4.gif" target="_blank">Figura 4</a></p>     <p>Del an&aacute;lisis din&aacute;mico del actuador de inserci&oacute;n se   obtiene:</p>       <p align="center"><a name="for3"></a><img src="img/revistas/rinbi/v4n8/v4n8a08for3.gif"></p>     <p>donde se tienen en cuenta los torques que se aplican   sobre el actuador de inserci&oacute;n del instrumento, siendo   w<sub>1->2</sub> el torque ejercido por el instrumento sobre el   actuador de traslaci&oacute;n, w<sub>3->2</sub> el torque ejercido por la   gu&iacute;a pasiva sobre el actuador, w<sub>g2</sub> el torque aplicado por   la fuerza de gravedad sobre el actuador y w<sub>d2</sub> el torque   ejercido por la inercia del actuador.</p>     <p>Del an&aacute;lisis din&aacute;mico de la gu&iacute;a pasiva se obtiene:</p>     <p align="center"><a name="for4"></a><img src="img/revistas/rinbi/v4n8/v4n8a08for4.gif"></p>     <p>donde se plantean los torques que act&uacute;an sobre la gu&iacute;a   pasiva, siendo w<sub>2->3</sub> el torque ejercido por el actuador de   traslaci&oacute;n sobre la gu&iacute;a pasiva, w<sub>1->3</sub> el torque producido   por la interacci&oacute;n entre el instrumento laparosc&oacute;pico y   la gu&iacute;a pasiva, w<sub>4->3</sub> es el torque que ejerce el sensor F/T   sobre la gu&iacute;a pasiva, siendo esta la magnitud que capta el   sensor para enviar al sistema de control.</p>     <p>Considerando (<a href="#for2">2</a>), (<a href="#for3">3</a>) y (<a href="#for4">4</a>) se obtiene:</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="for5"></a><img src="img/revistas/rinbi/v4n8/v4n8a08for5.gif"></p>     <p>donde se tiene que w<sub>1->7</sub> torque que ejerce el   instrumento sobre el &oacute;rgano, es una funci&oacute;n de w<sub>4->3</sub> que   es el torque que capta el sensor; w<sub>g</sub> = w<sub>g1</sub> + w<sub>g2</sub> + w<sub>g3</sub>,   que es la suma de los torques debidos a la gravedad; y   w<sub>d</sub> = w<sub>d1</sub> + w<sub>d2</sub> + w<sub>d3</sub>, que es la suma de los torques debidos   a la aceleraci&oacute;n. Si se tiene en cuenta que las velocidades   y aceleraciones en la <i>MIRS</i> son muy peque&ntilde;as, se puede   suponer que w<sub>d</sub> &asymp; 0; por lo que es posible deducir la fuerza   ejercida sobre el &oacute;rgano o tejido a partir de la magnitud   medida por el sensor F/T y por medio de un algoritmo que   compense el efecto de la gravedad.</p>     <p>Este modelo matem&aacute;tico est&aacute; validado por el   trabajo de Zemiti <i>et al</i> &#91;<a href="#36">36</a>&#93;., en el cual se incluy&oacute; dicho   modelo en el algoritmo de control de fuerza del robot   MC2E para realizar pruebas <i>in vitro</i> y pruebas <i>in vivo</i>  garantizando una fuerza de contacto m&aacute;xima para no   da&ntilde;ar el tejido.</p>     <p>&nbsp;</p>     <p><b><font size="3">V. CONCLUSI&Oacute;N</font></b></p>     <p>La cirug&iacute;a m&iacute;nimamente invasiva hace una transici&oacute;n   entre la cirug&iacute;a abierta convencional y la cirug&iacute;a rob&oacute;tica,   ya que presenta ventajas funcionales y est&eacute;ticas para   el paciente respecto a la cirug&iacute;a abierta, pero a la vez   genera inconvenientes para el cirujano que llegan a   ser solucionados con la cirug&iacute;a rob&oacute;tica. La cirug&iacute;a   rob&oacute;tica brinda, por tanto, mejores perspectivas para el   adecuado desempe&ntilde;o del acto quir&uacute;rgico. As&iacute;, poco a   poco los centros hospitalarios hacen transferencia de estas   tecnolog&iacute;as, realiz&aacute;ndose procedimientos quir&uacute;rgicos con   asistencia rob&oacute;tica bajo la modalidad de telecirug&iacute;a.</p>     <p>Las investigaciones tendientes a incluir la percepci&oacute;n   de fuerza y tacto por parte del cirujano en procedimientos   de cirug&iacute;a rob&oacute;tica son en la actualidad un campo abierto   de investigaci&oacute;n. Los desarrollos en esta &aacute;rea dar&aacute;n en un   futuro la posibilidad al cirujano de percibir la sensaci&oacute;n de   interacci&oacute;n entre el instrumental quir&uacute;rgico y los tejidos,   como si tuviera contacto directo con ellos. Algunos   trabajos experimentales en el &aacute;mbito mundial plantean el   uso de diferentes tipos de sensores y algoritmos de control   para incluir la realimentaci&oacute;n de fuerza en este tipo de   sistemas, entre los que se propone la ubicaci&oacute;n de sensores   en diferentes zonas del instrumental quir&uacute;rgico.</p>     <p>&nbsp;</p>     <p><b><font size="3">REFERENCIAS</font></b></p>     <!-- ref --><p>&#91;<a name="1">1</a>&#93;.  Wagner C. R.,   Howe R. D.  Force Feedback Benefit Depends on   Experience in Multiple Degree of Freedom Robotic Surgery Task.    <i>IEEE Transactions on Robotics</i>,   23(6),   1235-1240,   2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S1909-9762201000020000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="2">2</a>&#93;.  Ponsky T. A.,   Ponsky J. L.  Advances in Minimally Invasive   Surgery.  <i>Gastroenterology</i>,   136(4),   1171-1173,   2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S1909-9762201000020000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="3">3</a>&#93;.  Hanly E. J.,   Talamini M. A.  Robotic abdominal surgery.  <i>The   American Journal of Surgery</i>,   188(Supplement 1),   19-26,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S1909-9762201000020000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="4">4</a>&#93;.  Glasgow R. E.,  Adamson K. A.,  Mulvihill S. J.  The benefits of   a dedicated minimally invasive surgery program to academic   general surgery practice.  <i>Journal of Gastrointestinal Surgery</i>,     8(7),   869-873,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S1909-9762201000020000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="5">5</a>&#93;.  Fogel H. S. M.  Cirug&iacute;a rob&oacute;tica en M&eacute;xico. Los sistemas inteligentes,     perspectivas actuales y a futuro en el &aacute;mbito mundial.  <i>Revista   Mexicana de Cirug&iacute;a Endosc&oacute;pica</i>,   4(1),   45-50,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S1909-9762201000020000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="6">6</a>&#93;.  Preusche C.,  Ortmaier T.,  Hirzinger G.  Teleoperation concepts in   minimal invasive surgery.  <i>Control Engineering Practice</i>,   10(11),     1245-1250,   2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S1909-9762201000020000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="7">7</a>&#93;.  Drasin T.,  Dutson E.,  Gracia C.  Use of a robotic system as surgical   first assistant in advanced laparoscopic surgery.  <i>Journal of the   American College of Surgeons</i>,   199(3),   368-373,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S1909-9762201000020000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="8">8</a>&#93;.  Bodner J.,  Wykypiel H.,  Wetscher G.,  Schmid T.  First experiences   with the da Vinci (TM) operating robot in thoracic surgery.  <i>European   Journal of Cardio-Thoracic Surgery</i>,   25(5),   844-851,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S1909-9762201000020000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="9">9</a>&#93;.  Berman M.,  Stamler A.,  Vidne B. A.,  Saute M.  Computer-enhanced   thoracoscopic thymectomy with the Zeus telemanipulation   surgical system.  <i>Interactive Cardiovascular and Thoracic   Surgery</i>,   2(3),   262-264,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S1909-9762201000020000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="10">10</a>&#93;.  Argenziano M.,  Oz M. C.,  Kohmoto T.,  Morgan J.,  Dimitui J.,  Mongero L.,  Beck J.,  Smith C. R.  Totally Endoscopic Atrial Septal   Defect Repair With Robotic Assistance.  <i>Circulation</i>,   108(90101),     II-191-194,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S1909-9762201000020000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="11">11</a>&#93;.  Degueldre M.,  Vandromme J.,  Huong P. T.,  Cadiere G. B.    Robotically assisted laparoscopic microsurgical tubal   reanastomosis: a feasibility study.  <i>Fertility and Sterility</i>,   74(5),     1020-1023,   2000.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S1909-9762201000020000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="12">12</a>&#93;.  Mosso-V&aacute;zquez J. L.,  Minor-Mart&iacute;nez A.,  Lara-Vaca V.,  Garc&iacute;a-Palacios R.,  Pineda C. N.  Histerectom&iacute;a vaginal video asistida   a trav&eacute;s de un brazo rob&oacute;tico.  Reporte de un caso.  <i>Cirug&iacute;a y   Cirujanos</i>,   70(2),   105-108,   2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S1909-9762201000020000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="13">13</a>&#93;.  Gettman M. T.,  Blute M. L.,  Peschel R.,  Bartsch G.  Current Status   of Robotics in Urologic Laparoscopy.  <i>European Urology</i>,   43(2),     106-112,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S1909-9762201000020000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="14">14</a>&#93;.  Obando M.,  Liem L.,  Madauss W.,   Morita M.,   Robinson B.    Robotic surgery in pituitary tumors.  <i>Operative Techniques in   Otolaryngology-Head and Neck Surgery</i>,   15(2),   147-149,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S1909-9762201000020000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="15">15</a>&#93;.  Stevens L. M.  Laparoscopia.  <i>The Journal of American Medical   Association</i> (JAMA),   287(3),   402,   2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S1909-9762201000020000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="16">16</a>&#93;.  Feller R. L.,  Lau C. K. L.,  Wagner C. R.,  Perrin D. P.,  Howe R. D.  The   effect of force feedback on remote palpation.  <i>IEEE International   Conference on Robotics and Automation</i>,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S1909-9762201000020000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="17">17</a>&#93;.  Peirs J.,  Clijnen J.,  Reynaerts D.,  Brussel H. V.,   Herijgers P.,     Corteville B.,  Boone S.  A micro optical force sensor for force   feedback during minimally invasive robotic surgery.  <i>Sensors and   Actuators A: Physical</i>,   115(2-3),   447-455,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S1909-9762201000020000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="18">18</a>&#93;.  Kitagawa M.,  Dokko D.,  Okamura A. M.,  Yuh D. D.  Effect of   sensory substitution on suture-manipulation forces for robotic   surgical systems.  <i>Journal of Thoracic and Cardiovascular   Surgery</i>,   129(1),   151-158,   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S1909-9762201000020000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="19">19</a>&#93;.  Gasparetto A.,  Vidoni R.,  Zanotto V.  DFORCE: Delayed   FOrce ReferenCE control for master-slave robotic systems.    <i>Mechatronics</i>,   19(5),   639-646,   2009.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S1909-9762201000020000800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="20">20</a>&#93;.  Bicchi A.,  Canepa G.,  Rossi D. D.,  Iacconit P.,  Scil E. P.  A   Sensorized Minimally Invasive Surgery Tool for Detecting   Tissutal Elastic Properties.  <i>IEEE International Conference on   Robotics and Automation</i>,   Minneapolis,   Minnesota 1996.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S1909-9762201000020000800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="21">21</a>&#93;.  Suzuki S.,  Suzuki N.,  Hashizume M.,  Kakeji Y.,  Konishi K.,  Hattori A.,  Hayashibe M.  Tele-training simulation for the surgical   robot system "da Vinci".  <i>International Congress Series</i>,   1268,     86-91,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S1909-9762201000020000800021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="22">22</a>&#93;.  ATI.  <i>ATI Industrial Automation</i>.  Robotic End Effectors and   Automation Tooling.  Apex,   NC,   USA Consultado el 10 de   Febrero de 2007 en: <a href="http://www. ati-ia. com" target="_blank">http://www. ati-ia. com</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S1909-9762201000020000800022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="23">23</a>&#93;.  Ramming J.  JR3 Inc.  Davis,   USA Consultado el 15 de Abril de   2009 en: <a href="http://www. jr3. com/index. html" target="_blank">http://www. jr3. com/index. html</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S1909-9762201000020000800023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="24">24</a>&#93;.  Taylor R. H.,  Taylor R. H.,  Stoianovici D.  Medical robotics in   computer-integrated surgery.  IEEE <i>Transactions on Robotics and   Automation</i>,   19(5),   765-781,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S1909-9762201000020000800024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="25">25</a>&#93;.  Camarillo D. B.,  Krummel T. M.,  Salisbury J.,   J. Kenneth.  Robotic   technology in surgery: Past,   present,   and future.  <i>The American   Journal of Surgery</i>,   188(Supplement 1),   2-15,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S1909-9762201000020000800025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="26">26</a>&#93;.  Hanly E. J.,  Marohn M. R.,  Bachman S. L.,  Talamini M. A.,  Hacker   S. O.,  Howard R. S.,  Schenkman N. S.  Multiservice laparoscopic   surgical training using the da Vinci surgical system.  <i>The American   Journal of Surgery</i>,   187(2),   309-315,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S1909-9762201000020000800026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="27">27</a>&#93;.  Dupeyrat A. C.,  Ballantyne G. H.  Sistemas quir&uacute;rgicos rob&oacute;ticos y   telerob&oacute;ticos para cirug&iacute;a abdominal.  <i>Revista Gastroenterolog&iacute;a   Per&uacute;</i>,   23,   58-66,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S1909-9762201000020000800027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="28">28</a>&#93;.  Marohn C. M. R.,  Hanly C. E. J.  Twenty-first century surgery using   twenty-first century technology: Surgical robotics.  <i>Current   Surgery</i>,   61(5),   466-473,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S1909-9762201000020000800028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="29">29</a>&#93;.  Rosen J.,  Hannaford B.,  MacFarlane M. P.,  Sinanan M. N.  Force   Controlled and Teleoperated Endoscopic Grasper for Minimally   Invasive Surgery-Experimental Performance Evaluation.  <i>IEEE   Transactions on Biomedical Engineering</i>,   46(10),   1212-1221,   1999.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S1909-9762201000020000800029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="30">30</a>&#93;.  Sensable Technologies.  Consultado el 15 de Abril de 2008 en:   <a href="http://www. sensable. com/products-haptic-devices. htm" target="_blank">  http://www. sensable. com/products-haptic-devices. htm</a>.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000160&pid=S1909-9762201000020000800030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="31">31</a>&#93;.  Kennedy C. W.,  Hu T.,  P. Desai J.  Combining Haptic and Visual   Servoing for Cardiothoracic Surgery.  <i>Proceedings of IEEE   lntemational Conference on Robotics and Automation Washington</i>,     DC,   2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000162&pid=S1909-9762201000020000800031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="32">32</a>&#93;.  Tavakoli M.,  Patel R. V.,  M. Moallem.  A Force Reflective Master-Slave System for Minimally Invasive Surgery.  <i>Proceedings of   IEEE/RSl Conference on Intelligent Robots and Systems</i> Las   Vegas,   Nevada 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000164&pid=S1909-9762201000020000800032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="33">33</a>&#93;.  Seibold U.,  Kuebler B.,  Weiss H.,  Ortmaier T.,  Hirzinger G.    Sensorized and Actuated Instruments for Minimally Invasive   Robotic Surgery.  <i>EuroHaptics 2004</i>,   Munich Germany,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000166&pid=S1909-9762201000020000800033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="34">34</a>&#93;.  &Ouml;string M.,  Gunnarsson S.,  Norrl&ouml;f M.  Closed-loop identification   of an industrial robot containing flexibilities.  <i>Control Engineering   Practice</i>,   11(3),   291-300,   2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000168&pid=S1909-9762201000020000800034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="35">35</a>&#93;.  Tholey G.,  Pillarisetti A.,  Desai F. P.  On site three dimensional   force sensing capability in a laparoscopic grasper.  <i>Industrial   Robot: An International Journal</i>,   6,   509-518,   2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000170&pid=S1909-9762201000020000800035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="36">36</a>&#93;.  Zemiti N.,  Morel G.,  Ortmaier T.,  Bonnet N.  Mechatronic Design   of a New Robot for Force Control in Minimally Invasive Surgery.    <i>IEEE/ASME Transactions on Mechatronics</i>,   12(2),   143-153,   2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000172&pid=S1909-9762201000020000800036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="37">37</a>&#93;.  Deml B.,  Ortmaier T.,  Seibold U.  The Touch and Feel in   Minimally Invasive Surgery.  <i>HAVE 2005 - IEEE International   Workshop on Haptic Audio Visual Environments and their   Applications</i> Ottawa,   Ontario,   Canada,   33-38,   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000174&pid=S1909-9762201000020000800037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="38">38</a>&#93;.  Dargahi J.,  Najarian S.  A supported membrane type sensor for   medical tactile mapping.  <i>Sensor Review</i> 24(3),   284 - 297 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000176&pid=S1909-9762201000020000800038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="39">39</a>&#93;.  P&eacute;rez V.,  Kostka P.,  Kandora A.,  Guti&eacute;rrez L.  Verification of   Forward Kinematics and Trajectories for the Robin Heart Master   Tool.  International BioMed-Tech Silesia 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000178&pid=S1909-9762201000020000800039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="40">40</a>&#93;.  P&eacute;rez V.,  Medina C.,  Guti&eacute;rrez L. B.,  Bustamante J.,  Nawrat   Z.,  Kostka P.  Simulation of the master-slave system RobIn   Heart: kinematic an&aacute;lisis,   dynamic analysis and bilateral control   diagrams.  <i>Medical robots</i> 2007 Zabrze,   Poland,   2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000180&pid=S1909-9762201000020000800040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="41">41</a>&#93;.  Nawrat Z.,  Kostka P.  Polish cardio-robot "Robin Heart".  System   description and technical evaluation.  <i>The international Journal   of medical robotics and computer assisted surgery</i>,   2,   36-44,     2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000182&pid=S1909-9762201000020000800041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="42">42</a>&#93;.  Nawrat Z.,  Kostka P.,  Malota Z.  RobIn Heart Expert - Advisory   system and data base integrated with polish cardiac surgery robot.    <i>Minim. Invasiv. Ther. Allied Technol. </i>,   14(4-5),   295,   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000184&pid=S1909-9762201000020000800042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="43">43</a>&#93;.  Tejszerska D.,   <i>Analiza kinematyczno-dynamiczna ramienia robota   kardiochirurgicznego Robin Heart,   in Zaklad Mechaniki Og&oacute;lneji   Biomechaniki,   Wydzial Mechaniczny Technologiczny</i>.  2006,     Politechnika slaska w Gliwicach: Gliwice.  p.  70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000186&pid=S1909-9762201000020000800043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="44">44</a>&#93;.  Podsedkowski L.  RobIn Heart 0,  1,   and 3 - mechanical   construction development.  <i>Bulletin of the polish academy of   sciences</i>,   53(1),   79-85,   2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000188&pid=S1909-9762201000020000800044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="45">45</a>&#93;.  P&eacute;rez V. Z.,  Guti&eacute;rrez L. B.,  Kandora A.  Modeling of the master   in the bilateral control of the Robin Heart teleoperation system.    <i>Robotics 2006</i> Zabrze,   Poland,   2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000190&pid=S1909-9762201000020000800045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="46">46</a>&#93;.  P&eacute;rez V.,  Bustamante J.,  Betancur M.,  Espinosa J.,  Nawrat Z.    Desarrollo de un modelo generalizado para realimentaci&oacute;n de   fuerza y torque en cirug&iacute;a cardiotor&aacute;cica m&iacute;nimamente invasiva   rob&oacute;tica: determinaci&oacute;n de condiciones y restricciones.  <i>Revista   Colombiana de Cardiolog&iacute;a</i>,   2011 (En imprenta).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000192&pid=S1909-9762201000020000800046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="47">47</a>&#93;.  P&eacute;rez V.,  Bustamante J.,  Betancur M.,  Espinosa J.,  Nawrat Z.    Desarrollo de un modelo generalizado para realimentaci&oacute;n   de fuerza y torque en cirug&iacute;a cardiotor&aacute;cica m&iacute;nimamente   invasiva rob&oacute;tica: determinaci&oacute;n de condiciones y restricciones.    <i>Congreso Colombiano de Cardiolog&iacute;a</i>,   Cartagena,   Colombia,     2010.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000194&pid=S1909-9762201000020000800047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="48">48</a>&#93;.  Faraz A.,  Payandeh S.  Engineering approaches to mechanical and   robotic design for minimally invasive surgeries,   2000.  Vol,   183.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000196&pid=S1909-9762201000020000800048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="49">49</a>&#93;.  Payandeh S.  Force Propagation Models in Laparoscopic Tools   and Trainers.  <i>Proceedings - 19th International Conference -IEEE/EMBS</i>,  Chicago,   IL.  USA,   1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000198&pid=S1909-9762201000020000800049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>       <!-- ref --><p>&#91;<a name="50">50</a>&#93;.  Gupta V.,  Gupta V.,  Reddy N. P.,  Batur P.  Forces in surgical   tools: comparison between laparoscopic and surgical forceps.      <i>Engineering in Medicine and Biology Society,   1996.  Bridging   Disciplines for Biomedicine.  Proceedings of the 18th Annual   International Conference of the IEEE</i>,   1996.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000200&pid=S1909-9762201000020000800050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>   </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
<name>
<surname><![CDATA[Howe]]></surname>
<given-names><![CDATA[R.D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Force Feedback Benefit Depends on Experience in Multiple Degree of Freedom Robotic Surgery Task]]></article-title>
<source><![CDATA[IEEE Transactions on Robotics]]></source>
<year>2007</year>
<volume>23</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1235-1240</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ponsky]]></surname>
<given-names><![CDATA[T.A]]></given-names>
</name>
<name>
<surname><![CDATA[Ponsky]]></surname>
<given-names><![CDATA[J.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advances in Minimally Invasive Surgery]]></article-title>
<source><![CDATA[Gastroenterology]]></source>
<year>2009</year>
<volume>136</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1171-1173</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hanly]]></surname>
<given-names><![CDATA[E.J]]></given-names>
</name>
<name>
<surname><![CDATA[Talamini]]></surname>
<given-names><![CDATA[M.A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Robotic abdominal surgery]]></article-title>
<source><![CDATA[The American Journal of Surgery]]></source>
<year>2004</year>
<volume>188</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>19-26</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Glasgow]]></surname>
<given-names><![CDATA[R.E]]></given-names>
</name>
<name>
<surname><![CDATA[Adamson]]></surname>
<given-names><![CDATA[K.A]]></given-names>
</name>
<name>
<surname><![CDATA[Mulvihill]]></surname>
<given-names><![CDATA[S.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The benefits of a dedicated minimally invasive surgery program to academic general surgery practice]]></article-title>
<source><![CDATA[Journal of Gastrointestinal Surgery]]></source>
<year>2004</year>
<volume>8</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>869-873</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fogel]]></surname>
<given-names><![CDATA[H.S.M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cirugía robótica en México: Los sistemas inteligentes, perspectivas actuales y a futuro en el ámbito mundial]]></article-title>
<source><![CDATA[Revista Mexicana de Cirugía Endoscópica]]></source>
<year>2003</year>
<volume>4</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>45-50</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Preusche]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ortmaier]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hirzinger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Teleoperation concepts in minimal invasive surgery]]></article-title>
<source><![CDATA[Control Engineering Practice]]></source>
<year>2002</year>
<volume>10</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1245-1250</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Drasin]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Dutson]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Gracia]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of a robotic system as surgical first assistant in advanced laparoscopic surgery]]></article-title>
<source><![CDATA[Journal of the American College of Surgeons]]></source>
<year>2004</year>
<volume>199</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>368-373</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bodner]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wykypiel]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Wetscher]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Schmid]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[First experiences with the da Vinci (TM) operating robot in thoracic surgery]]></article-title>
<source><![CDATA[European Journal of Cardio-Thoracic Surgery]]></source>
<year>2004</year>
<volume>25</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>844-851</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Stamler]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vidne]]></surname>
<given-names><![CDATA[B.A]]></given-names>
</name>
<name>
<surname><![CDATA[Saute]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computer-enhanced thoracoscopic thymectomy with the Zeus telemanipulation surgical system]]></article-title>
<source><![CDATA[Interactive Cardiovascular and Thoracic Surgery]]></source>
<year>2003</year>
<volume>2</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>262-264</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Argenziano]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Oz]]></surname>
<given-names><![CDATA[M.C]]></given-names>
</name>
<name>
<surname><![CDATA[Kohmoto]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Morgan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dimitui]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mongero]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Beck]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Totally Endoscopic Atrial Septal Defect Repair With Robotic Assistance]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2003</year>
<volume>108</volume>
<numero>90101</numero>
<issue>90101</issue>
<page-range>191-194</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Degueldre]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Vandromme]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Huong]]></surname>
<given-names><![CDATA[P.T]]></given-names>
</name>
<name>
<surname><![CDATA[Cadiere]]></surname>
<given-names><![CDATA[G.B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Robotically assisted laparoscopic microsurgical tubal reanastomosis: a feasibility study]]></article-title>
<source><![CDATA[Fertility and Sterility]]></source>
<year>2000</year>
<volume>74</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1020-1023</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mosso-Vázquez]]></surname>
<given-names><![CDATA[J.L]]></given-names>
</name>
<name>
<surname><![CDATA[Minor-Martínez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lara-Vaca]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[García-Palacios]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pineda]]></surname>
<given-names><![CDATA[C.N]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Histerectomía vaginal video asistida a través de un brazo robótico: Reporte de un caso]]></article-title>
<source><![CDATA[Cirugía y Cirujanos]]></source>
<year>2002</year>
<volume>70</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>105-108</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gettman]]></surname>
<given-names><![CDATA[M.T]]></given-names>
</name>
<name>
<surname><![CDATA[Blute]]></surname>
<given-names><![CDATA[M.L]]></given-names>
</name>
<name>
<surname><![CDATA[Peschel]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bartsch]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Current Status of Robotics in Urologic Laparoscopy]]></article-title>
<source><![CDATA[European Urology]]></source>
<year>2003</year>
<volume>43</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>106-112</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Obando]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Liem]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Madauss]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Morita]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Robinson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Robotic surgery in pituitary tumors]]></article-title>
<source><![CDATA[Operative Techniques in Otolaryngology-Head and Neck Surgery]]></source>
<year>2004</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>147-149</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stevens]]></surname>
<given-names><![CDATA[L.M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Laparoscopia]]></article-title>
<source><![CDATA[The Journal of American Medical Association]]></source>
<year>2002</year>
<volume>287</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>402</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feller]]></surname>
<given-names><![CDATA[R.L]]></given-names>
</name>
<name>
<surname><![CDATA[Lau]]></surname>
<given-names><![CDATA[C.K.L]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[C.R]]></given-names>
</name>
<name>
<surname><![CDATA[Perrin]]></surname>
<given-names><![CDATA[D.P]]></given-names>
</name>
<name>
<surname><![CDATA[Howe]]></surname>
<given-names><![CDATA[R.D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of force feedback on remote palpation]]></article-title>
<source><![CDATA[IEEE International Conference on Robotics and Automation]]></source>
<year>2004</year>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peirs]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Clijnen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Reynaerts]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Brussel]]></surname>
<given-names><![CDATA[H.V]]></given-names>
</name>
<name>
<surname><![CDATA[Herijgers]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Corteville]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Boone]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A micro optical force sensor for force feedback during minimally invasive robotic surgery]]></article-title>
<source><![CDATA[Sensors and Actuators A: Physical]]></source>
<year>2004</year>
<volume>115</volume>
<numero>2-3</numero>
<issue>2-3</issue>
<page-range>447-455</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kitagawa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dokko]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Okamura]]></surname>
<given-names><![CDATA[A.M]]></given-names>
</name>
<name>
<surname><![CDATA[Yuh]]></surname>
<given-names><![CDATA[D.D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of sensory substitution on suture-manipulation forces for robotic surgical systems]]></article-title>
<source><![CDATA[Journal of Thoracic and Cardiovascular Surgery]]></source>
<year>2005</year>
<volume>129</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>151-158</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gasparetto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vidoni]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Zanotto]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[DFORCE: Delayed FOrce ReferenCE control for master-slave robotic systems]]></article-title>
<source><![CDATA[Mechatronics]]></source>
<year>2009</year>
<volume>19</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>639-646</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bicchi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Canepa]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Rossi]]></surname>
<given-names><![CDATA[D.D]]></given-names>
</name>
<name>
<surname><![CDATA[Iacconit]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Scil]]></surname>
<given-names><![CDATA[E.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Sensorized Minimally Invasive Surgery Tool for Detecting Tissutal Elastic Properties]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Conference on Robotics and Automation]]></conf-name>
<conf-date>1996</conf-date>
<conf-loc>Minneapolis Minnesota</conf-loc>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suzuki]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Suzuki]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hashizume]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kakeji]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Konishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hattori]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashibe]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tele-training simulation for the surgical robot system "da Vinci"]]></article-title>
<source><![CDATA[International Congress Series]]></source>
<year>2004</year>
<volume>1268</volume>
<page-range>86-91</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="">
<collab>ATI</collab>
<source><![CDATA[ATI Industrial Automation: Robotic End Effectors and Automation Tooling]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramming]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[JR3 Inc. Davis, USA]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[R.H]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[R.H]]></given-names>
</name>
<name>
<surname><![CDATA[Stoianovici]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Medical robotics in computer-integrated surgery]]></article-title>
<source><![CDATA[IEEE Transactions on Robotics and Automation]]></source>
<year>2003</year>
<volume>19</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>765-781</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camarillo]]></surname>
<given-names><![CDATA[D.B]]></given-names>
</name>
<name>
<surname><![CDATA[Krummel]]></surname>
<given-names><![CDATA[T.M]]></given-names>
</name>
<name>
<surname><![CDATA[Salisbury]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kenneth]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Robotic technology in surgery: Past, present, and future]]></article-title>
<source><![CDATA[The American Journal of Surgery]]></source>
<year>2004</year>
<volume>188</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>2-15</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hanly]]></surname>
<given-names><![CDATA[E.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Marohn]]></surname>
<given-names><![CDATA[M.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Bachman]]></surname>
<given-names><![CDATA[S.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Talamini]]></surname>
<given-names><![CDATA[M.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Hacker]]></surname>
<given-names><![CDATA[S.O.]]></given-names>
</name>
<name>
<surname><![CDATA[Howard]]></surname>
<given-names><![CDATA[R.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Schenkman]]></surname>
<given-names><![CDATA[N.S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multiservice laparoscopic surgical training using the da Vinci surgical system]]></article-title>
<source><![CDATA[The American Journal of Surgery]]></source>
<year>2004</year>
<volume>187</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>309-315</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dupeyrat]]></surname>
<given-names><![CDATA[A.C]]></given-names>
</name>
<name>
<surname><![CDATA[Ballantyne]]></surname>
<given-names><![CDATA[G.H]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistemas quirúrgicos robóticos y telerobóticos para cirugía abdominal]]></article-title>
<source><![CDATA[Revista Gastroenterología Perú]]></source>
<year>2003</year>
<volume>23</volume>
<page-range>58-66</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marohn]]></surname>
<given-names><![CDATA[C.M.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Hanly]]></surname>
<given-names><![CDATA[C.E.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Twenty-first century surgery using twenty-first century technology: Surgical robotics]]></article-title>
<source><![CDATA[Current Surgery]]></source>
<year>2004</year>
<volume>61</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>466-473</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hannaford]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[MacFarlane]]></surname>
<given-names><![CDATA[M.P]]></given-names>
</name>
<name>
<surname><![CDATA[Sinanan]]></surname>
<given-names><![CDATA[M.N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Force Controlled and Teleoperated Endoscopic Grasper for Minimally Invasive Surgery-Experimental Performance Evaluation]]></article-title>
<source><![CDATA[IEEE Transactions on Biomedical Engineering]]></source>
<year>1999</year>
<volume>46</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1212-1221</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="">
<source><![CDATA[Sensable Technologies]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kennedy]]></surname>
<given-names><![CDATA[C.W.]]></given-names>
</name>
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[P. Desai]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Combining Haptic and Visual Servoing for Cardiothoracic Surgery]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE lntemational Conference on Robotics and Automation Washington]]></conf-name>
<conf-date>2002</conf-date>
<conf-loc>DC DC</conf-loc>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tavakoli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Patel]]></surname>
<given-names><![CDATA[R.V]]></given-names>
</name>
<name>
<surname><![CDATA[Moallem]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Force Reflective Master-Slave System for Minimally Invasive Surgery]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE/RSl Conference on Intelligent Robots and Systems]]></conf-name>
<conf-date>2003</conf-date>
<conf-loc>Las Vegas Nevada</conf-loc>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Seibold]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Kuebler]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Weiss]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ortmaier]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hirzinger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sensorized and Actuated Instruments for Minimally Invasive Robotic Surgery]]></article-title>
<source><![CDATA[EuroHaptics 2004]]></source>
<year>2004</year>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Östring]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gunnarsson]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Norrlöf]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Closed-loop identification of an industrial robot containing flexibilities]]></article-title>
<source><![CDATA[Control Engineering Practice]]></source>
<year>2003</year>
<volume>11</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>291-300</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tholey]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Pillarisetti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Desai]]></surname>
<given-names><![CDATA[F.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On site three dimensional force sensing capability in a laparoscopic grasper]]></article-title>
<source><![CDATA[Industrial Robot: An International Journal]]></source>
<year>2004</year>
<volume>6</volume>
<page-range>509-518</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zemiti]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Morel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Ortmaier]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Bonnet]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechatronic Design of a New Robot for Force Control in Minimally Invasive Surgery]]></article-title>
<source><![CDATA[IEEE/ASME Transactions on Mechatronics]]></source>
<year>2007</year>
<volume>12</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>143-153</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deml]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ortmaier]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Seibold]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Touch and Feel in Minimally Invasive Surgery]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[ IEEE International Workshop on Haptic Audio Visual Environments and their Applications]]></conf-name>
<conf-loc>Ottawa Ontario</conf-loc>
</nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dargahi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Najarian]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A supported membrane type sensor for medical tactile mapping]]></article-title>
<source><![CDATA[Sensor Review]]></source>
<year>2004</year>
<volume>24</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>284 - 297</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Kostka]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kandora]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Verification of Forward Kinematics and Trajectories for the Robin Heart Master Tool]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Medina]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[L.B]]></given-names>
</name>
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nawrat]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Kostka]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simulation of the master-slave system RobIn Heart: kinematic análisis, dynamic analysis and bilateral control diagrams]]></article-title>
<source><![CDATA[Medical robots]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nawrat]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Kostka]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Polish cardio-robot "Robin Heart": System description and technical evaluation]]></article-title>
<source><![CDATA[The international Journal of medical robotics and computer assisted surgery]]></source>
<year>2006</year>
<volume>2</volume>
<page-range>36-44</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nawrat]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Kostka]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Malota]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[RobIn Heart Expert - Advisory system and data base integrated with polish cardiac surgery robot]]></article-title>
<source><![CDATA[Minim. Invasiv. Ther. Allied Technol.]]></source>
<year>2005</year>
<volume>14</volume>
<numero>4-5</numero>
<issue>4-5</issue>
<page-range>295</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tejszerska]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analiza kinematyczno-dynamiczna ramienia robota kardiochirurgicznego Robin Heart]]></article-title>
<source><![CDATA[Zaklad Mechaniki Ogólneji Biomechaniki, Wydzial Mechaniczny Technologiczny]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Podsedkowski]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[RobIn Heart 0, 1, and 3 - mechanical construction development]]></article-title>
<source><![CDATA[Bulletin of the polish academy of sciences]]></source>
<year>2005</year>
<volume>53</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>79-85</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[V.Z]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[L.B]]></given-names>
</name>
<name>
<surname><![CDATA[Kandora]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modeling of the master in the bilateral control of the Robin Heart teleoperation system]]></article-title>
<source><![CDATA[Robotics 2006]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Betancur]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Espinosa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nawrat]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Desarrollo de un modelo generalizado para realimentación de fuerza y torque en cirugía cardiotorácica mínimamente invasiva robótica: determinación de condiciones y restricciones]]></article-title>
<source><![CDATA[Revista Colombiana de Cardiología]]></source>
<year>2011</year>
</nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Betancur]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Espinosa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nawrat]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<source><![CDATA[Desarrollo de un modelo generalizado para realimentación de fuerza y torque en cirugía cardiotorácica mínimamente invasiva robótica: determinación de condiciones y restricciones]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Faraz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Payandeh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Engineering approaches to mechanical and robotic design for minimally invasive surgeries]]></source>
<year>2000</year>
</nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Payandeh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Force Propagation Models in Laparoscopic Tools and Trainers]]></article-title>
<source><![CDATA[]]></source>
<year></year>
<conf-name><![CDATA[19 International Conference]]></conf-name>
<conf-date>1997</conf-date>
<conf-loc>Chicago IL</conf-loc>
</nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Reddy]]></surname>
<given-names><![CDATA[N.P]]></given-names>
</name>
<name>
<surname><![CDATA[Batur]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Forces in surgical tools: comparison between laparoscopic and surgical forceps]]></article-title>
<source><![CDATA[Engineering in Medicine and Biology Society, 1996: Bridging Disciplines for Biomedicine]]></source>
<year></year>
<conf-name><![CDATA[18 Annual International Conference of the IEEE]]></conf-name>
<conf-date>1996</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
