<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5552</journal-id>
<journal-title><![CDATA[Revista Salud Uninorte]]></journal-title>
<abbrev-journal-title><![CDATA[Salud, Barranquilla]]></abbrev-journal-title>
<issn>0120-5552</issn>
<publisher>
<publisher-name><![CDATA[Fundación Universidad del Norte, División de Ciencias de la]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-55522016000200013</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Valoración cuantitativa para la reincorporación ocupacional]]></article-title>
<article-title xml:lang="en"><![CDATA[Quantitative assessment for the occupational reintegration]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Montoya-Leal]]></surname>
<given-names><![CDATA[Vanessa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[Vera Z]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Pontificia Bolivariana  ]]></institution>
<addr-line><![CDATA[Tunja ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Pontificia Bolivariana  ]]></institution>
<addr-line><![CDATA[Tunja ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>05</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>05</month>
<year>2016</year>
</pub-date>
<volume>32</volume>
<numero>2</numero>
<fpage>319</fpage>
<lpage>336</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-55522016000200013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-55522016000200013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-55522016000200013&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen El progreso de la bioingeniería ha permitido el desarrollo de herramientas tecnológicas para cuantificar las variables asociadas al examen físico. En este artículo se presenta la descripción, ventajas y limitaciones de tecnologías para la medición de fuerza, arcos de movimiento, equilibrio y estabilidad, coordinación y marcha. Se proponen también alternativas para uso de estas tecnologías como parte del proceso de valoración de pacientes complejos, ya sea porque se sospeche simulación o porque presenten lesiones graves en las que se requiera sugerir opciones en el proceso de rehabilitación o cierre de caso. En tales circunstancias se identifican alternativas para un diagnóstico más completo que disminuyan la subjetividad del terapeuta y con mayores posibilidades de monitoreo.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract The progress of bioengineering has allowed the development of technological tools to quantify the variables associated to the physical assessment process. The description, advantages and limitations of technologies to measure the strength, range of motion, balance and stability, coordination and gait are shown. Some alternatives are proposed for using those technologies as part of the appreciation process in complex patients, either for any suspicion of simulation or because any serious injury can exist where some alternatives for rehabilitation process are required. In such cases, must be identified some options for a more complete diagnosis, decreasing the subjectivity of the therapist and with more monitoring possibilities.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[valoración cuantitativa]]></kwd>
<kwd lng="es"><![CDATA[tecnología innovadora]]></kwd>
<kwd lng="es"><![CDATA[análisis biomecánico]]></kwd>
<kwd lng="es"><![CDATA[rehabilitación funcional]]></kwd>
<kwd lng="es"><![CDATA[salud ocupacional]]></kwd>
<kwd lng="en"><![CDATA[quantitative evaluation]]></kwd>
<kwd lng="en"><![CDATA[Innovative technology]]></kwd>
<kwd lng="en"><![CDATA[biomechanical analysis]]></kwd>
<kwd lng="en"><![CDATA[functional rehabilitation]]></kwd>
<kwd lng="en"><![CDATA[occupational health]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font face="Verdana" size="2">      <p align="center"><font size="4"><b>Valoraci&oacute;n cuantitativa para la reincorporaci&oacute;n ocupacional</b></font></p>      <p align="center"><font size="3"><b>Quantitative assessment for the occupational reintegration</b></font></p>      <p>Vanessa Montoya-Leal<a name="n1"></a><a href="#n_1"><sup>1</sup></a>, Vera Z. P&eacute;rez<a name="n2"></a><a href="#n_2"><sup>2</sup></a></p>      <p><a name="n_1"></a><a href="#n1"><sup>1</sup></a>  Fisioterapeuta, estudiante de Maestr&iacute;a en Ingenier&iacute;a. Investigadora Centro de Bioingenier&iacute;a, Universidad Pontificia Bolivariana. Tunja, Colombia.</p>      <p><a name="n_2"></a><a href="#n2"><sup>2</sup></a> Docente, Facultad Ingenier&iacute;a Electr&oacute;nica. Investigadora Centro de Bioingenier&iacute;a, Universidad Pontificia Bolivariana. Tunja, Colombia.</p>      <p><B>Correspondencia: </B>Julieth Vanessa Montoya Leal, Circular 1 n&deg; 73-48. Tel: 4488388, ext. 12402. <a href="mailto:julieth.montoyal@upb.edu.com">julieth.montoyal@upb.edu.com</a></p>     <p><I>Fecha de recepci&oacute;n:</I> 11 de octubre de 2015    <br> <I>Fecha de aceptaci&oacute;n:</I> 15 de enero de 2016</p> <hr>      <P><B>Resumen</b></p>      ]]></body>
<body><![CDATA[<p><I>El progreso de la bioingenier&iacute;a ha permitido el desarrollo de herramientas tecnol&oacute;gicas para cuantificar las variables asociadas al examen f&iacute;sico. En este art&iacute;culo se presenta la descripci&oacute;n, ventajas y limitaciones de tecnolog&iacute;as para la medici&oacute;n de fuerza, arcos de movimiento, equilibrio y estabilidad, coordinaci&oacute;n y marcha. Se proponen tambi&eacute;n alternativas para uso de estas tecnolog&iacute;as como parte del proceso de valoraci&oacute;n de pacientes complejos, ya sea porque se sospeche simulaci&oacute;n o porque presenten lesiones graves en las que se requiera sugerir opciones en el proceso de rehabilitaci&oacute;n o cierre de caso. En tales circunstancias se identifican alternativas para un diagn&oacute;stico m&aacute;s completo que disminuyan la subjetividad del terapeuta y con mayores posibilidades de monitoreo.</I></p>      <p><B>Palabras clave: </B>valoraci&oacute;n cuantitativa, tecnolog&iacute;a innovadora, an&aacute;lisis biomec&aacute;nico, rehabilitaci&oacute;n funcional, salud ocupacional.</p> <hr>      <P><B>Abstract</b></p>      <p><I>The progress of bioengineering has allowed the development of technological tools to quantify the variables associated to the physical assessment process. The description, advantages and limitations of technologies to measure the strength, range of motion, balance and stability, coordination and gait are shown. Some alternatives are proposed for using those technologies as part of the appreciation process in complex patients, either for any suspicion of simulation or because any serious injury can exist where some alternatives for rehabilitation process are required. In such cases, must be identified some options for a more complete diagnosis, decreasing the subjectivity of the therapist and with more monitoring possibilities.</I></p>      <p><B>Keywords:</B> quantitative evaluation, Innovative technology, biomechanical analysis, functional rehabilitation, occupational health.</p> <hr>      <p><b>INTRODUCCI&Oacute;N</b></p>      <p>La rehabilitaci&oacute;n tiene como objetivo recobrar la funcionalidad de una persona respecto a las actividades de la vida diaria, laborales y sociales, mediante una serie de t&eacute;cnicas y procedimientos determinados seg&uacute;n el tipo de patolog&iacute;a, la etapa en que se encuentre y la etiolog&iacute;a de la misma.</p>      <p>Cuando se presenta un evento de enfermedad o accidente laboral, el objetivo de la rehabilitaci&oacute;n consiste en que el empleado logre la reincorporaci&oacute;n ocupacional (1); proceso regido por las normatividades establecidas en el Sistema de Gesti&oacute;n de Seguridad y Salud en el Trabajo (2) con el fin de garantizar un &oacute;ptimo desempe&ntilde;o en la actividad laboral.</p>      <p>Seg&uacute;n el manual de procedimientos para la rehabilitaci&oacute;n y reincorporaci&oacute;n ocupacional de los trabajadores en el Sistema General de Riesgos Profesionales, existen cuatro etapas en el manejo de los casos, incluyendo rehabilitaci&oacute;n funcional y rehabilitaci&oacute;n profesional (1).</p>      <p>En cuanto a la <I>rehabilitaci&oacute;n profesional,</I> existen herramientas con valor cuantitativo para la determinaci&oacute;n del factor de riesgo de la actividad laboral, las cuales buscan facilitar la adaptaci&oacute;n del empleado a su puesto de trabajo de acuerdo con sus capacidades (3). Por el contrario, en la <I>rehabilitaci&oacute;n funcional</I> se busca optimizar las capacidades musculoesquel&eacute;ticas para el desempe&ntilde;o de las actividades diarias y laborales; sin embargo, la valoraci&oacute;n f&iacute;sica actual es predominantemente cualitativa, debido a que tiene como referencia diferentes variables como signos y s&iacute;ntomas mediante la aplicaci&oacute;n de test y maniobras establecidos a lo largo de la historia.</p>      ]]></body>
<body><![CDATA[<p>En estos test y maniobras se valora de forma subjetiva el dolor, mediante una escala an&aacute;loga (4), de forma objetiva la fuerza, la postura, el rango articular y la antropometr&iacute;a, mediante estrategias visuales, manuales e instrumentales; y de forma funcional el comportamiento mediante la observaci&oacute;n del paciente, sus afecciones y su conducta frente a las dificultades en el desempe&ntilde;o de funciones (5) ; por tanto, se hace necesaria la implementaci&oacute;n de herramientas que permitan cuantificar mejor el estado funcional del paciente favoreciendo un an&aacute;lisis menos subjetivo.</p>      <p>A partir de la experiencia fisioterap&eacute;utica se han identificado diversas necesidades en el entorno, ya que se encuentran pocas herramientas que permitan la medici&oacute;n cuantitativa de variables asociadas a la reincorporaci&oacute;n ocupacional o dificultad en el acceso a las mismas. De hecho, en el proceso de rehabilitaci&oacute;n solo se hace, en general, registro cuantitativo de la antropometr&iacute;a y el rango articular a trav&eacute;s de la cinta m&eacute;trica y la goniometr&iacute;a, respectivamente. Estas herramientas, sin embargo, no son frecuentemente utilizadas y no permiten una medici&oacute;n continua durante toda la sesi&oacute;n de valoraci&oacute;n.</p>      <p>La informaci&oacute;n cuantitativa de estas variables permitir&iacute;a al personal del &aacute;rea de la salud hacer una mejor identificaci&oacute;n de la condici&oacute;n funcional del paciente para objetivar el plan de tratamiento y determinar los procedimientos que se deben seguir, o seg&uacute;n el caso, una identificaci&oacute;n de los pacientes simuladores para definir el cierre de caso y continuar con el procedimiento ocupacional pertinente. En este orden de ideas, se hace necesario el reconocimiento de tecnolog&iacute;as que permitan un an&aacute;lisis cuantitativo de las variables asociadas a la rehabilitaci&oacute;n funcional.</p>      <p>Como consecuencia de la problem&aacute;tica planteada, este art&iacute;culo muestra las diferentes variables que se tienen en cuenta en la valoraci&oacute;n completa del paciente por parte del fisioterapeuta, y se presenta para cada una de ellas la manera convencional en que se realiza dicha valoraci&oacute;n y las alternativas tecnol&oacute;gicas disponibles en el estado del arte en la b&uacute;squeda de una valoraci&oacute;n cuantitativa. En la secci&oacute;n 2 se presentan cada una de las variables y el listado de tecnolog&iacute;as identificadas en el estado del arte con un an&aacute;lisis de las ventajas y las limitaciones dentro de la pr&aacute;ctica de fisioterapia. En la  secci&oacute;n 3 se presentan algunas marcas reconocidas de proveedores y usuarios de tecnolog&iacute;a y menciona algunas herramientas adicionales que mezclan diferentes variables de inter&eacute;s. En la secci&oacute;n 4 se hace una reflexi&oacute;n respecto al uso en el medio de las tecnolog&iacute;as citadas, y la secci&oacute;n 5 se presentan las conclusiones.</p>      <p><b>VARIABLES DE LA VALORACI&Oacute;N</b></p>      <p>Para que el fisioterapeuta pueda hacer una valoraci&oacute;n completa debe tener en cuenta el grupo de variables que se presenta en la <a href="#f1">figura 1</a>, donde se visualiza la manera en que se hace la valoraci&oacute;n de cada una de dichas variables en el entorno colombiano, lo cual tiene mucha similitud con otros pa&iacute;ses latinoamericanos.</p>     <p align="center"><a name="f1"></a><img src="img/revistas/sun/v32n2/v32n2a13f01.jpg"></p>      <p>En la primera fila se encuentra el nombre de cada una de las variables, en la segunda, las t&eacute;cnicas tradicionales utilizadas para diagnosticar dichas variables de forma subjetiva a trav&eacute;s de consulta externa, y en la tercera, las t&eacute;cnicas tradicionales (bastante escasas) para diagnosticar cuantitativamente aspectos relacionados con dichas variables. </p>      <p><b>FUERZA</b></p>      <p>Desde el punto de vista t&eacute;cnico, <I>fuerza</I> se refiere a la capacidad que posee un m&uacute;sculo para generar contracci&oacute;n, permitiendo realizar un movimiento, sostenerlo o frenarlo (6). En la pr&aacute;ctica de fisioterapia tradicional, la fuerza se mide de forma cualitativa mediante observaci&oacute;n de la musculatura, palpaci&oacute;n y aplicaci&oacute;n de un Test de Fuerza (Daniels (7) o escala de Kendall (8)).</p>      ]]></body>
<body><![CDATA[<p>La fuerza es una variable que en algunos casos intenta ser alterada por el paciente, pretendiendo realizar menor fuerza de la que es capaz. En esos casos es de utilidad tener algunas alternativas de valoraci&oacute;n cuantitativa, como las siguientes:</p>      <p><B>a. Electromiograf&iacute;a</B>: Puede utilizarse como m&eacute;todo o estrategia para objetivar la medici&oacute;n de la fuerza muscular gracias a que permite la identificaci&oacute;n de la activaci&oacute;n de uno o varios grupos musculares (9).</p>      <p>La principal limitaci&oacute;n de este m&eacute;todo consiste en que para uso en fisioterapia la t&eacute;cnica debe ser electromiograf&iacute;a de superficie, la cual no permite obtener de forma directa la fuerza ejercida por el grupo muscular evaluado; sin embargo, puede brindar informaci&oacute;n complementaria a trav&eacute;s del procesamiento de se&ntilde;ales (10,11) utilizando caracter&iacute;sticas de la se&ntilde;al mioel&eacute;ctrica en el dominio del tiempo o de la frecuencia, usando diferentes algoritmos, como la transformada de Fourier o la transformada de Wavelet (12).</p>      <p>En otros estudios realizados para hacer comparaciones de las se&ntilde;ales se deben tomar referencias individuales entre el miembro afectado y el sano, ya que al presentar las mismas caracter&iacute;sticas morfofisiol&oacute;gicas se puede determinar que el error resultante entre dos m&uacute;sculos sanos es inferior al error resultante entre un m&uacute;sculo sano y uno afectado (13).</p>      <p>Adicionalmente se puede realizar procesamiento de la se&ntilde;al mediante la fatiga muscular; ya que al realizar un esfuerzo con un tipo de contracci&oacute;n y un tiempo determinado, la frecuencia y amplitud de la se&ntilde;al deber&aacute;n ser similares en cada repetici&oacute;n, lo cual podr&iacute;a ayudar a identificar el paciente simulador (14).</p>      <p>Actualmente existe gran variedad de equipos de electromiograf&iacute;a, desde los tradicionales de m&uacute;ltiples canales con electrodos cableados (15) hasta los m&aacute;s modernos inal&aacute;mbricos, que permiten hacer adquisici&oacute;n de las se&ntilde;ales mientras se realiza un deporte o se hacen movimientos bajo el agua (16,17).</p>      <p><B>b. Galga extensiom&eacute;trica:</B> Consiste en un dispositivo de medici&oacute;n que mide deformaci&oacute;n e indirectamente presi&oacute;n, carga, torque, posici&oacute;n o fuerza. En el caso de la fuerza, la medici&oacute;n se hace por tensi&oacute;n o compresi&oacute;n, variando la resistencia seg&uacute;n el esfuerzo al que va ser sometido (18). Estos elementos son utilizados como principio de acci&oacute;n de sensores de fuerza, celdas de carga y otras herramientas tecnol&oacute;gicas que permiten la valoraci&oacute;n cuantitativa de la variable fuerza y que pueden ser aplicadas a grupos musculares en pacientes. Un ejemplo de ellos es el sistema PowerLab de la empresa AD Instruments (19), que utiliza como sensor externo de medici&oacute;n una celda de carga para presentar al usuario el dato de fuerza m&aacute;xima al realizar el ejercicio de prensi&oacute;n.</p>      <p>La galga extensiom&eacute;trica espec&iacute;ficamente tiene el inconveniente de la necesidad de experticia para su montaje y manipulaci&oacute;n, ya que requiere definir adecuadamente los puntos donde ser&aacute; ubicada, ser adherida con resina o similar en la superficie de inter&eacute;s y construir o adquirir un sistema de bioinstrumentaci&oacute;n para transformar las micro deformaciones en variables el&eacute;ctricas que sean f&aacute;cilmente medidas (18). Adicionalmente, el proceso de selecci&oacute;n de la galga debe ser riguroso y adaptado a la aplicaci&oacute;n, y es susceptible a las variaciones de temperatura, que deben ser compensados desde el circuito de bioinstrumentaci&oacute;n. Existen, sin embargo, m&uacute;ltiples sistemas que ya han resuelto estos problemas de ingenier&iacute;a y ofrecen alternativas que puede ser usadas directamente por el paciente con base en celdas de carga u otros sistemas construidos, teniendo como elemento principal las galgas extensiom&eacute;tricas (20).</p>      <p><B>c. Dinamometr&iacute;a:</B> Es una herramienta tecnol&oacute;gica que combina la inform&aacute;tica y la rob&oacute;tica, con el objetivo de medir cuantitativamente la capacidad muscular (21), expresada en fuerza m&aacute;xima, potencia o fatiga muscular. Puede ser utilizada como m&aacute;quina de entrenamiento de potencia muscular o como herramienta para la valoraci&oacute;n f&iacute;sica del componente muscular e incluso articular (22). Cuando el sistema se ajusta a la biomec&aacute;nica del paciente, modificando la resistencia seg&uacute;n la fuerza aplicada para mantener una velocidad constante, se denomina &ldquo;sistema pasivo&rdquo;; por el contrario, se denomina &ldquo;sistema activo&rdquo; cuando la fuerza es aplicada sobre el paciente (21).</p>      <p>La evaluaci&oacute;n se debe realizar de forma comparativa, y consiste en la ejecuci&oacute;n de varias repeticiones de movimiento, estableciendo metodolog&iacute;a y criterio de estudio entre una o varias variables, como la relaci&oacute;n entre m&uacute;sculo sano/afectado, contracci&oacute;n conc&eacute;ntrica/exc&eacute;ntrica, fuerza m&aacute;xima/velocidad de movimiento, comportamiento muscular en diferentes rangos de movilidad articular y /o fatiga muscular por contracci&oacute;n isom&eacute;trica; de esta manera se podr&aacute; realizar un an&aacute;lisis de los resultados determinando valores de normalidad o alteraci&oacute;n seg&uacute;n la variable (22).</p>      ]]></body>
<body><![CDATA[<p>Esta prueba se puede complementar con el uso de electromiograf&iacute;a, ya que al realizar el movimiento se puede observar el aumento o disminuci&oacute;n en la se&ntilde;al gr&aacute;fica seg&uacute;n el n&uacute;mero de unidades motoras reclutadas (14). Adem&aacute;s, mediante el an&aacute;lisis de velocidad de movimiento se puede identificar si el sujeto intenta modificar la fuerza ejercida; debido a que cuando se realiza un movimiento, el punto inicial de velocidad es igual a 0, va aumentando hasta llegar a un valor m&aacute;ximo en la mitad del gesto y posteriormente disminuye hasta alcanzar nuevamente 0 al finalizar el movimiento; por tal raz&oacute;n, los datos almacenados deber&iacute;an ser similares al realizar diferentes repeticiones.</p>      <p>Esta herramienta puede ser de gran ayuda a la hora de determinar la capacidad f&iacute;sica del paciente cuando lleva mucho tiempo de incapacidad o se sospeche de una simulaci&oacute;n. Sin embargo, la principal desventaja de los dinam&oacute;metros comerciales existentes consiste en que solo permiten hacer evaluaci&oacute;n sobre una articulaci&oacute;n y en un plano de movimiento determinado; adem&aacute;s, el dise&ntilde;o de fabricaci&oacute;n hace que sea dif&iacute;cil realizar valoraciones del tronco; as&iacute; mismo, por tratarse de un equipo robusto, sus costos son elevados (21,23), por lo que su uso no es tan frecuente, aunque en la actualidad se han desarrollado avances en este producto que permiten acceder a equipos m&aacute;s econ&oacute;micos y mejores dise&ntilde;os que facilitan el manejo para los diferentes ejes de movimiento (24).</p>      <p>De igual manera, se han desarrollado herramientas hidr&aacute;ulicas y port&aacute;tiles para la valoraci&oacute;n de mano y espalda (25), lo cual puede permitir un mejor acceso respecto al uso del dispositivo, pero al ser una herramienta an&aacute;loga, no permitir&iacute;a realizar un an&aacute;lisis tan detallado de los resultados.</p>      <p><b>ARCOS DE MOVIMIENTO</b></p>      <p>Los <I>arcos de movimiento</I> hacen referencia a la totalidad de movilidad que presenta cada articulaci&oacute;n en cada plano anat&oacute;mico dentro de los l&iacute;mites que proporcionan las estructuras articulares (5).</p>      <p>La evaluaci&oacute;n de esta variable se realiza mediante la observaci&oacute;n del movimiento activo y pasivo, por medici&oacute;n del &aacute;ngulo articular utilizando diferentes elementos:</p>      <p><B>a. Goni&oacute;metro y cinta m&eacute;trica:</B> Estas herramientas corresponden a la forma tradicional y manual de medir directa o indirectamente el &aacute;ngulo de movimiento articular.</p>      <p>La <I>forma indirecta</I> se hace a trav&eacute;s del test de flexibilidad y de la medici&oacute;n de longitud con la cinta m&eacute;trica; en este caso, la longitud medida no es realmente la variable de movimiento angular y la t&eacute;cnica no permite aislar el an&aacute;lisis de un solo segmento. La <I>forma directa</I> m&aacute;s com&uacute;n se hace a trav&eacute;s del goni&oacute;metro manual, que aunque da una medida del &aacute;ngulo articular, por ser un elemento anal&oacute;gico incluye errores de paralaje, y adicionalmente tiene el inconveniente de no permitir un monitoreo constante de dicho &aacute;ngulo (26).</p>      <p>Por otra parte, en algunas ocasiones se ha identificado la falta de colaboraci&oacute;n del paciente, realizando resistencias que no permiten completar el rango articular que puede llegar a alcanzar; por esta raz&oacute;n es de gran ventaja utilizar herramientas tecnol&oacute;gicas que permitan almacenar datos exactos de los &aacute;ngulos obtenidos en cada repetici&oacute;n de movimiento indicado, de tal forma que los movimientos del paciente puedan ser m&aacute;s naturales.</p>      <p>Algunas herramientas tecnol&oacute;gicas m&aacute;s modernas, de acuerdo con los inconvenientes visualizados anteriormente, son el goni&oacute;metro electr&oacute;nico y el inclin&oacute;metro doble electr&oacute;nico, como una variaci&oacute;n de la goniometr&iacute;a anal&oacute;gica, con los que por medio de la implementaci&oacute;n de sensores cinem&aacute;ticos y digitales se valora el rango de movimiento articular en diferentes planos de movimiento (2, 28).</p>      ]]></body>
<body><![CDATA[<p>Actualmente existe gran variedad de goni&oacute;metros electr&oacute;nicos, digitales (29) y herramientas de f&aacute;cil acceso a trav&eacute;s de aplicaciones m&oacute;viles que permiten la medici&oacute;n del rango articular a muy bajo costo (30). Si estas herramientas se pueden complementar con el uso de un <I>software</I>, podr&iacute;an generar el almacenamiento de datos para una posterior comparaci&oacute;n con el &aacute;ngulo de movimiento, lo cual actualmente es una limitaci&oacute;n para la mayor&iacute;a de los goni&oacute;metros que se utilizan en el medio.</p>      <p>Cuando la valoraci&oacute;n se realiza con sensores directamente sobre los segmentos, existe la posibilidad de valorar el rango articular en diferentes movimientos simult&aacute;neamente al adherir un electrodo sobre la zona articular y el otro en el segmento continuo (31), lo cual facilita el continuo monitoreo durante la valoraci&oacute;n y evita la interferencia en la medida que se puede presentar al utilizar un goni&oacute;metro an&aacute;logo.</p>      <p><B>b. Fotograma y Videograma:</B> Consisten en un sistema de c&aacute;maras infrarrojas que detectan los puntos anat&oacute;micos que se van a evaluar por medio de la marcaci&oacute;n de los segmentos &oacute;seos con marcadores reflectivos en la piel del paciente, lo cual permite el an&aacute;lisis biomec&aacute;nico del movimiento.</p>      <p>Esta t&eacute;cnica acompa&ntilde;ada de reconstrucci&oacute;n 3D demostr&oacute; muy buenos resultados en el an&aacute;lisis de mano, y logr&oacute; obtener los &aacute;ngulos rotacionales entre los segmentos con m&iacute;nimo error en la ejecuci&oacute;n (32).</p>      <p>Es importante resaltar que la funcionalidad de este sistema es muy completa, ya que, como se mencion&oacute;, permite un an&aacute;lisis confiable de todos los segmentos corporales, incluyendo segmentos m&aacute;s peque&ntilde;os como son los de la mano, ya que actualmente se cuenta con poca tecnolog&iacute;a que logre analizar detalladamente dichos segmentos.</p>      <p>Adem&aacute;s, existe gran variedad de <I>softwares</I> en el mercado que permiten editar la imagen o grabaci&oacute;n de video, haciendo &eacute;nfasis en un gesto o movimiento deseado para posteriormente hacer un an&aacute;lisis del rango articular; entre ellos se encuentra Kinovea, y gracias a que est&aacute; dise&ntilde;ado como una herramienta educativa, es de f&aacute;cil acceso al ser una aplicaci&oacute;n gratuita. Al ingresar a un sitio web espec&iacute;fico se puede descargar desde cualquier ordenador; sin embargo, este <I>software </I>es un poco limitado funcionalmente, ya que solo admite el an&aacute;lisis de movimientos en un solo plano (33).</p>      <p>Por otro lado, existe la posibilidad de complementar este sistema con otros dispositivos tecnol&oacute;gicos de acuerdo con los objetivos planteados con el fin de mejorar la calidad del an&aacute;lisis o ampliar el estudio de las variables.</p>      <p>c. <B>Juegos serios:</B> Consisten en la aplicaci&oacute;n de videojuegos elaborados con fines espec&iacute;ficos; uno de estos ha sido implementar sensores de movimiento para la utilizaci&oacute;n de los mismos en el &aacute;rea de fisioterapia.</p>      <p>Esta tecnolog&iacute;a se aplica principalmente en programas de rehabilitaci&oacute;n, con el fin de involucrar al paciente de una forma m&aacute;s din&aacute;mica y entretenida, y mejora aspectos como la motivaci&oacute;n, memoria y capacidades f&iacute;sicas (34), por lo tanto, podr&iacute;a ser una herramienta &uacute;til para la valoraci&oacute;n del movimiento articular, especialmente en pacientes que intentan simular y demostrar un rango articular inferior; debido a que al envolverse en el juego podr&aacute; realizar movimientos de manera menos consciente, lo cual brinda la posibilidad de obtener datos cuantitativos de los gestos realizados.</p>      <p>Se han adaptado incluso algunos sistemas y plataformas de videojuegos para aplicaci&oacute;n en juegos serios; entre ellos se encuentra el Sensor Kinect, que permite la conexi&oacute;n entre la consola y el <I>software</I>, almacenando datos para una posterior comparaci&oacute;n (35).</p>      ]]></body>
<body><![CDATA[<p>Igualmente se puede destacar que a pesar de los grandes avances tecnol&oacute;gicos de la actualidad, en el &aacute;rea de la salud a&uacute;n existen grandes deficiencias en cuanto al tema (34), lo cual hace pertinente la investigaci&oacute;n y el desarrollo de equipos relacionados con videojuegos para la implementaci&oacute;n en salud.</p>      <p><b>EQUILIBRIO Y ESTABILIDAD</b></p>      <p>El <I>equilibrio</I> se puede definir como la relaci&oacute;n de la postura respecto a las fuerzas internas o externas que act&uacute;an sobre el cuerpo, y la <I>estabilidad</I> hace referencia a la capacidad de mantener el cuerpo en equilibrio, ya sea de forma est&aacute;tica, reactiva o din&aacute;mica (36).</p>      <p>Habitualmente, en fisioterapia el equilibrio se eval&uacute;a por medio de la observaci&oacute;n de las respuestas motrices ante los cambios de posiciones, aplicaciones de est&iacute;mulos o interacci&oacute;n con superficies que generen inestabilidad y diferenciaci&oacute;n al realizar la actividad propuesta con los ojos abiertos y cerrados.</p>      <p>Otras variables por evaluar en la estabilidad son las compensaciones y alteraciones biomec&aacute;nicas, observando la inestabilidad p&eacute;lvica en los diferentes planos, la descoordinaci&oacute;n lumbo-p&eacute;lvica, alteraciones del centro de gravedad, alteraci&oacute;n del ritmo escapulohumeral, patrones torsionales, de flexi&oacute;n o extensi&oacute;n en los diferentes segmentos, y las alteraciones en el apoyo plantar (36, 37).</p>      <p>En la actualidad se han venido desarrollando tecnolog&iacute;as que facilitan la valoraci&oacute;n de estas variables f&iacute;sicas con el fin de proporcionar al evaluador datos m&aacute;s exactos que desde el punto de vista del profesional podr&iacute;an ser imperceptibles o dif&iacute;cilmente medibles. Algunas herramientas cuantitativas para equilibrio y estabilidad son:</p>      <p><B>a. Plataformas:</B> Son dispositivos tecnol&oacute;gicos que tienen como principio de funcionamiento sensores de fuerza y presi&oacute;n unidos a un <I>software</I> que permiten la valoraci&oacute;n postural y de equilibrio en sus diferentes variables (38, 39). Se clasifican como plataformas de estabilometr&iacute;a y dinamometr&iacute;a; ambas plataformas eval&uacute;an las fuerzas de contacto, el desplazamiento del centro de presiones y la capacidad de marcha y equilibrio. Se puede realizar de forma est&aacute;tica y din&aacute;mica, aplicando diferentes est&iacute;mulos, como cambios de apoyo, est&iacute;mulos visuales, complejidad en los movimientos y cambios en las superficies (2, 40).</p>      <p>Adicionalmente, estas plataformas se pueden complementar con el uso de herramientas tecnol&oacute;gicas como la fotovideogametr&iacute;a, inclinometr&iacute;a, galgas extensiom&eacute;tricas y electromiograf&iacute;a, que brindan una valoraci&oacute;n m&aacute;s integral (41).</p>      <p>Existen m&uacute;ltiples empresas desarrolladoras de este tipo de plataformas que en muchos casos ofrecen un sistema completo (<I>hardware, software</I>, instalaci&oacute;n), con costos que pueden parecer altos pero que brindan informaci&oacute;n cuantitativa que no podr&iacute;a obtenerse de la forma tradicional.</p>      <p>Algunos profesionales del &aacute;rea consideran el aspecto econ&oacute;mico uno de los principales inconvenientes al intentar adoptar este tipo de tecnolog&iacute;a.</p>      ]]></body>
<body><![CDATA[<p><B>b. Baropodometr&iacute;a:</B> Consiste en un sistema de evaluaci&oacute;n del pie que permite determinar las alteraciones que se pueden presentar, por medio del centro de presi&oacute;n plantar, el porcentaje de carga transmitida, el contorno del pie, el &aacute;ngulo de la b&oacute;veda plantar, las presiones plantares diferenciadas mediante colores, el punto de m&aacute;xima presi&oacute;n y los mapas de presiones (42, 43).</p>      <p>Estudios han demostrado que por medio de esta tecnolog&iacute;a se puede cuantificar la valoraci&oacute;n del paciente, lo cual permite un mejor diagn&oacute;stico y direcci&oacute;n del plan de rehabilitaci&oacute;n. Lamentablemente, en algunos casos no ha sido muy implementado debido a altos costos del equipo; sin embargo, en la actualidad se han desarrollado diferentes herramientas que permitan cuantificar datos en posiciones est&aacute;ticas y din&aacute;micas, como plataformas y plantillas (electr&oacute;nicas y digitales) (28, 42, 43) y que presentan mayor variabilidad econ&oacute;mica.</p>      <p><b>COORDINACI&Oacute;N Y MARCHA</b></p>      <p>La <I>coordinaci&oacute;n</I> hace referencia a la orden estructural entre el sistema nervioso central (SNC) y el sistema musculoesquel&eacute;tico para realizar un movimiento &oacute;ptimo; tambi&eacute;n es definido como &ldquo;armonizaci&oacute;n de todas las fuerzas externas e internas teniendo en cuenta todos los ejes de movimiento del aparato motor para resolver adecuadamente una tarea motora propuesta&rdquo; (44).</p>      <p>En la valoraci&oacute;n fisioterap&eacute;utica convencional se determina si la coordinaci&oacute;n se encuentra conservada o alterada mediante test que permite apreciar la coordinaci&oacute;n &oacute;culo-manual, &oacute;culo-p&eacute;dica y la agilidad en los movimientos (45). En este caso tambi&eacute;n ser&iacute;a &uacute;til la aplicaci&oacute;n de las plataformas de videojuegos que permitan la cuantificaci&oacute;n de los par&aacute;metros por evaluar en la coordinaci&oacute;n.</p>      <p>La <I>marcha</I> es un ciclo que genera locomoci&oacute;n en el ser humano; est&aacute; compuesta por fases de apoyo, de balanceo y de despegue; adem&aacute;s involucra diferentes estructuras articulares, musculares y tendinosas que se encargan de brindar estabilidad, coordinaci&oacute;n y absorci&oacute;n para generar una mec&aacute;nica &oacute;ptima.</p>      <p>La valoraci&oacute;n fisioterap&eacute;utica tradicional se realiza mediante la observaci&oacute;n para determinar si la marcha es normal, patol&oacute;gica o se encuentra alterada; al igual que la medici&oacute;n con cinta m&eacute;trica de miembros inferiores para determinar la simetr&iacute;a o asimetr&iacute;a que presenta y su influencia en el desarrollo de la marcha (41, 46).</p>      <p>La valoraci&oacute;n tradicional de la marcha podr&iacute;a no ser tan espec&iacute;fica al tratarse de datos cualitativos que pueden ser percibidos de forma diferente de acuerdo con la experticia del profesional y de la colaboraci&oacute;n del paciente, ya que la marcha puede ser modificada pretendiendo mostrar dificultades al realizarla. Por esta raz&oacute;n se estima de gran utilidad el uso de herramientas tecnol&oacute;gicas que permitan acceder a datos confiables y cuantificables en su valoraci&oacute;n.</p>      <p>Para este an&aacute;lisis biomec&aacute;nico se pueden combinar diferentes herramientas tecnol&oacute;gicas para brindar una valoraci&oacute;n m&aacute;s completa; siendo principalmente utilizadas nuevamente las plataformas bien sea de estabilometr&iacute;a o dinamometr&iacute;a, junto con un sistema de videograma (41).</p>      <p>Otras investigaciones sugieren adem&aacute;s la implementaci&oacute;n de un sistema de baropodometr&iacute;a digital, que permite el an&aacute;lisis del comportamiento de las estructuras del pie durante la fase de balanceo, electromiograf&iacute;a para analizar el comportamiento muscular, inclinometr&iacute;a para evaluar la biomec&aacute;nica de la columna vertebral al realizar diferentes movimientos o posiciones y galgas extensiom&eacute;tricas para medir las fuerzas de presiones (18,27,41,47).</p>      ]]></body>
<body><![CDATA[<p><b>ELEMENTOS COMPLEMENTARIOS PARA EL AN&Aacute;LISIS BIOMEC&Aacute;NICO</b></p>      <p>Las herramientas tecnol&oacute;gicas mencionadas son de gran utilidad para el profesional que desee incorporar en su pr&aacute;ctica cl&iacute;nica el complemento entre medici&oacute;n cualitativa y cuantitativa. La <a href="#t1">tabla 1</a> presenta algunas de las principales marcas proveedoras o usuarias de este tipo de herramientas para cada una de las variables analizadas en la secci&oacute;n 2; sin embargo, existen varios desarrollos adicionales que pueden ser de inter&eacute;s para el profesional en el &aacute;rea de la fisioterapia, rehabilitaci&oacute;n o valoraci&oacute;n funcional, puesto que de forma simult&aacute;nea miden diferentes variables.</p>     <p align="center"><a name="t1"></a><img src="img/revistas/sun/v32n2/v32n2a13f02.jpg"></p>      <p>A continuaci&oacute;n se presentan algunos dispositivos o elementos que pueden servir como complemento para las tecnolog&iacute;as anteriormente mencionadas y son agrupados de acuerdo con las herramientas tecnol&oacute;gicas que utilicen para su funcionamiento, desde los sistemas que usan instrumentaci&oacute;n y procesamiento de im&aacute;genes (que se aprecian en la <a href="#f2">figura 2</a>) los que utilizan instrumentaci&oacute;n y procesamiento de biose&ntilde;ales, (que se observan en la <a href="#f3">figura 3</a>) hasta los que tienen un enfoque biomecatr&oacute;nico en su concepci&oacute;n y que son usados en procesos de rehabilitaci&oacute;n, tales como exoesqueletos o trajes adaptables al cuerpo humano (49, 63).</p>     <p align="center"><a name="f2"></a><img src="img/revistas/sun/v32n2/v32n2a13f03.jpg"></p>     <p align="center"><a name="f3"></a><img src="img/revistas/sun/v32n2/v32n2a13f04.jpg"></p>     <p align="center">Figura 3. Instrumentaci&oacute;n y procesamiento de biose&ntilde;ales (47, 66)</p>      <p><b>POSIBILIDADES PARA LA MEDICI&Oacute;N DE VARIABLES CUANTITATIVAS</b></p>      <p>A partir del an&aacute;lisis de las tecnolog&iacute;as existentes y de las posibilidades de integrarlas al proceso de valoraci&oacute;n en pacientes se proponen varias alternativas. Es de anotar que ninguna de estas iniciativas contempla reemplazar la labor del fisioterapeuta ni del personal de salud ocupacional; se trata, por el contrario, de mantener la evaluaci&oacute;n cualitativa, pero potencializar las habilidades del profesional, lo cual permite una valoraci&oacute;n m&aacute;s precisa y un mejor seguimiento a los procesos de rehabilitaci&oacute;n.</p>      <p>La <a href="#f4">figura 4</a> presenta el diagrama de flujo de la propuesta de inclusi&oacute;n de medici&oacute;n de variables de forma cuantitativa en el proceso de valoraci&oacute;n f&iacute;sica, incluyendo las tecnolog&iacute;as asociadas a cada variable del examen f&iacute;sico.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f4"></a><img src="img/revistas/sun/v32n2/v32n2a13f05.jpg"></p>      <p>Cabe anotar que para la selecci&oacute;n de los equipos se debe tener presente el tipo de patolog&iacute;a que presenta el paciente, los segmentos asociados que se desean evaluar, bien sea en miembros superiores, miembros inferiores o vertebrales; los movimientos y los planos en que se realizan las pruebas y finalmente los datos que se quiere obtener.</p>      <p>Como caso pr&aacute;ctico se presenta una propuesta de evaluaci&oacute;n para patolog&iacute;as relacionadas con enfermedades laborales de miembro superior, tales como s&iacute;ndrome de manguito rotador, epicondilitis, t&uacute;nel del carpo, entre otras. En este caso se utilizan las herramientas tecnol&oacute;gicas para evaluaci&oacute;n de fuerza y arco de movimiento porque son las variables directamente afectadas con las enfermedades mencionadas y, por tanto, las que presentan distorsiones en el momento de realizar valoraciones y monitoreos. Para la cuantificaci&oacute;n de fuerza muscular se propone utilizar dinamometr&iacute;a y galgas extensiom&eacute;tricas implementadas en una celda de carga que permita determinar la fuerza ejercida por el paciente, teniendo en cuenta que de acuerdo con los grupos musculares involucrados se dise&ntilde;a el protocolo con los ejercicios. Adicionalmente se utiliza electromiograf&iacute;a de superficie para caracterizar o clasificar el comportamiento muscular respecto a la fuerza. Si para la prueba es necesario realizar alg&uacute;n movimiento o gesto espec&iacute;fico, es importante llevar un registro del rango de movimiento articular durante la ejecuci&oacute;n de la prueba; y para ello es posible implementar un electrogoni&oacute;metro o la videogrametr&iacute;a, de tal forma que sea posible correlacionar la evaluaci&oacute;n de la fuerza y el arco de movimiento.</p>      <p>Para el caso de valoraciones en patolog&iacute;as que involucren miembro inferior, alteraciones de estabilidad y marcha, como por ejemplo la lumbalgia, es favorable el uso de las herramientas tecnol&oacute;gicas adicionales que se observan en la <a href="#f4">figura 4</a>.</p>      <p>Una adquisici&oacute;n interesante y no muy costosa para complementar de forma cuantitativa el an&aacute;lisis relacionado con coordinaci&oacute;n, marcha, equilibrio y estabilidad es una plataforma de marcha. Dicho sistema puede incluir la compra de plataformas a base de galgas extensiom&eacute;tricas u otro sistema de medici&oacute;n de fuerza, que puede ser construido a partir de videogrametr&iacute;a comercial o puede ser una mezcla de los dos. Para el caso de la videogrametr&iacute;a puede construirse un sistema de an&aacute;lisis en 2D usando incluso aplicaciones libres para computador. Una adaptaci&oacute;n en este sentido permite complementar la informaci&oacute;n para el fisioterapeuta con la visualizaci&oacute;n de curvas identificadoras del patr&oacute;n de marcha, y de esta forma facilita la identificaci&oacute;n del estado actual del paciente y el seguimiento del progreso.</p>      <p>Indudablemente, el uso de estas tecnolog&iacute;as debe ir unido a una capacitaci&oacute;n para poder leer de forma adecuada la informaci&oacute;n que estos sistemas entregan, o crear alianzas en las que los organismos de rehabilitaci&oacute;n y algunas entidades expertas en el uso de la tecnolog&iacute;a trabajen de forma mancomunada en pro del paciente.</p>      <p>Los juegos serios son una alternativa que puede tener m&uacute;ltiples variantes que no necesariamente implican altos costos, como por ejemplo la adaptaci&oacute;n, con peque&ntilde;as modificaciones para que el paciente realice una actividad diferente mientras asiste a la consulta.</p>      <p>El hecho de que la concentraci&oacute;n principal no se encuentre en la interacci&oacute;n con el terapeuta para el proceso de diagn&oacute;stico sino en avanzar en los niveles del juego hace que los movimientos sean m&aacute;s naturales y la valoraci&oacute;n m&aacute;s eficiente.</p>      <p>De forma similar, este tipo de sistemas son muy &uacute;tiles en los procesos de rehabilitaci&oacute;n, puesto que evita que el paciente se concentre &uacute;nicamente en su proceso y, por el contrario, quede inmerso en el entretenimiento que estos dispositivos pueden proporcionar.</p>      <p><b>DISCUSI&Oacute;N Y CONCLUSIONES</b></p>      ]]></body>
<body><![CDATA[<p>Actualmente existen tecnolog&iacute;as para la medici&oacute;n cuantitativa de cada una de las variables asociadas con la biomec&aacute;nica, como la electromiograf&iacute;a, la dinamometr&iacute;a y las galgas extensiom&eacute;tricas para evaluar la fuerza muscular(9-11, 15-20); el goni&oacute;metro e inclin&oacute;metro modernos, la fotovideogametr&iacute;a y los juegos serios para evaluar el arco de movimiento articular de forma continua (27-30, 32-35); la baropodometr&iacute;a y las plataformas de estabilometr&iacute;a y dinamometr&iacute;a para evaluar estabilidad, equilibrio, coordinaci&oacute;n y marcha (27-40, 42, 43).</p>      <p>Los procesos actuales de reincorporaci&oacute;n laboral asociados con la rehabilitaci&oacute;n funcional se hacen principalmente de forma cualitativa; sin embargo, la propuesta de este art&iacute;culo es el uso adecuado de este tipo de tecnolog&iacute;as para facilitar la valoraci&oacute;n f&iacute;sica en los casos complejos como lesiones graves o identificaci&oacute;n de un paciente simulador.</p>      <p>Es importante destacar que en la pr&aacute;ctica convencional se presentan factores de subjetividad por parte del profesional, como diagn&oacute;stico a trav&eacute;s de m&eacute;todos que dependen de la percepci&oacute;n visual y manual del fisioterapeuta (4, 5). Adem&aacute;s, en la experiencia pr&aacute;ctica se percibe una interacci&oacute;n y registro ampliamente cualitativo con registro cuantitativo solamente para determinadas variables y situaciones est&aacute;ticas; al igual que casos de exageraci&oacute;n de la sintomatolog&iacute;a y falta de colaboraci&oacute;n con el fin de obtener ganancias secundarias.</p>      <p>En este orden de ideas, con ayuda de los sistemas tecnol&oacute;gicos presentados es posible eliminar gran parte de los factores de subjetividad, como errores de paralaje o medici&oacute;n de fuerza.</p>      <p>Otra ventaja consiste en que permite aplicar diferentes metodolog&iacute;as y criterios de evaluaci&oacute;n para realizar an&aacute;lisis de correlaci&oacute;n y/o an&aacute;lisis de los resultados de las variables estudiadas de forma m&aacute;s detallada (12-14, 22).</p>      <p>Tambi&eacute;n puede involucrar de forma entretenida al paciente, para lograr obtener movimientos inconscientes y as&iacute; poder determinar valores reales (34). Adicionalmente se tiene la posibilidad de realizar an&aacute;lisis din&aacute;micos y de complementar el estudio con el uso de varias tecnolog&iacute;as simult&aacute;neamente; algunas pueden ser las ya mencionadas (27, 40, 42, 43), o incluso otras relacionadas con procesamiento de im&aacute;genes, como magnetoscopio, resonancia magn&eacute;tica o termograf&iacute;a infrarroja (41, 47, 64, 65), entre otras. Esto permite determinar con mayor convicci&oacute;n los procedimientos que se deben seguir o la necesidad de cierre de caso en situaciones complejas.</p>      <p>Todo lo anterior repercutir&aacute; en beneficio para el paciente, quien tendr&aacute; acceso a una m&aacute;s completa valoraci&oacute;n y diagn&oacute;stico. En la pr&aacute;ctica implica que se establecen mejor los objetivos de rehabilitaci&oacute;n, siendo m&aacute;s efectivos y eficientes en los procesos; lo cual se puede traducir indirectamente en calidad de atenci&oacute;n, efectividad en el tratamiento y posible disminuci&oacute;n de costos a largo plazo.</p>      <p>Sin embargo, implica la ejecuci&oacute;n de un procedimiento m&aacute;s riguroso; al igual que un conocimiento previo en el uso de las tecnolog&iacute;as y en la utilidad de las mismas, lo cual facilitar&aacute; el an&aacute;lisis de resultados. Adicionalmente requiere en algunos casos inversiones de las instituciones involucradas o apoyo con centros especialistas unidos en red.</p>      <p><B>Conflicto de intereses:</B> Los autores declaran que no existe conflicto de intereses en el desarrollo ni publicaci&oacute;n de este trabajo.</p>      <p><B>Financiaci&oacute;n: </B>El personal asociado al desarrollo de este proyecto fue financiado por la Universidad Pontificia Bolivariana.</p> <hr>      ]]></body>
<body><![CDATA[<p><b>REFERENCIAS</b></p>      <!-- ref --><p>1. Cifuentes-Pi&ntilde;eros C, Boada-Mojica J, Candia-Ospina R, Mart&iacute;nez-Segura P, Maldonado- Ram&iacute;rez G et al. <I>Manual de procedimientos para la rehabilitaci&oacute;n y reincorporaci&oacute;n ocupacional de los trabajadores en el sistema general de riesgos profesionales.</I> 3<U><Sup>a</Sup></U><Sup> </Sup>ed. Rep&uacute;blica de Colombia:Ministerio de la Protecci&oacute;n Social Direcci&oacute;n General de Riesgos Profesionales; 2010.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753117&pid=S0120-5552201600020001300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>2. Decreto 1072 de 2015. Por medio del cual se expide el Decreto &Uacute;nico Reglamentario del Sector Trabajo. Rep&uacute;blica de Colombia: Ministerio de Trabajo; 2015.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753119&pid=S0120-5552201600020001300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>3. Guti&eacute;rrez-Strauss. <I>Gu&iacute;a t&eacute;cnica para el an&aacute;lisis de exposici&oacute;n a factores de riesgo ocupacional. </I>Rep&uacute;blica de Colombia: Ministerio de la Protecci&oacute;n Social; 2011.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753121&pid=S0120-5552201600020001300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>4. Pardo C, Mu&ntilde;oz T, Chamorro C. Monitorizaci&oacute;n del dolor: Recomendaciones del grupo de trabajo de analgesia y sedaci&oacute;n de la SEMICYUC. <I>Medicina intensiva</I> 2006; 30(8):379-385.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753123&pid=S0120-5552201600020001300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>5. Dur&aacute;n F S &amp; Agudelo LHL (Eds.). <I>Rehabilitaci&oacute;n en salud, 2</I>. Universidad de Antioquia; 2008, p. 39-74.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753125&pid=S0120-5552201600020001300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>6. Gonz&aacute;lez-Badillo J, Gorostiaga-Ayestar&aacute;n E. <I>Fundamentos del entrenamiento de la fuerza: Aplicaci&oacute;n al alto rendimiento deportivo</I>. 3&ordf; ed. Barcelona: INDE Publicaciones; 2002. p. 1-63.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753127&pid=S0120-5552201600020001300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>7. Hislop H, Montgomery J. <I>Pruebas funcionales musculares.</I> Madrid: Marban. 2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753129&pid=S0120-5552201600020001300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>8. Kendall  FP, Kendall E, Geise P, McIntyre M, Anthony WM. <I>Pruebas Funcionales. Postura y Dolor.</I> 2007.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753131&pid=S0120-5552201600020001300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>9. De Luca CJ. The use of surface electromyography in biomechanics.<I>Journal of applied biomechanics</I> 1997;13(2):135-163.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753133&pid=S0120-5552201600020001300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>10. Sanabria J J &amp; Archila JF. Detecci&oacute;n y an&aacute;lisis de movimiento usando visi&oacute;n artificial. <I>Scientia Et Technica</I> 2011;<I>3</I>(49):180-188.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753135&pid=S0120-5552201600020001300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>11. &Aacute;lvarez-Fiallo R, Santos-Anzorand&iacute;a C &amp; Medina-Herrera E. Implementaci&oacute;n de la electromiograf&iacute;a cuantitativa para el estudio de las enfermedades neuromusculares. <I>Revista Cubana de Medicina Militar</I>2005,<I> </I>(1):0-0.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753137&pid=S0120-5552201600020001300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>12. Canal MR. Comparison of wavelet and short time Fourier transform methods in the analysis of EMG signals. <I>Journal of medical systems</I> 2010; 34(1):91-94. doi:10.1007/s10916-008-9219-8&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753139&pid=S0120-5552201600020001300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Santaf&eacute; YE, Chaparro BD, Franco, J. Detecci&oacute;n de patrones caracter&iacute;sticos con transformadas wavelet en se&ntilde;ales electromiogr&aacute;ficas del cu&aacute;driceps. <I>Revista Colombiana de Tecnologias de Avanzada (RCTA)</I> 2013:<I>2</I>(20): 151-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753140&pid=S0120-5552201600020001300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>14. Calvo RH. El laboratorio de biomec&aacute;nica como ayuda en el dise&ntilde;o del puesto de trabajo. INERMAP. &Aacute;rea de Biomec&aacute;nica. Zaragoza (Espa&ntilde;a);2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753142&pid=S0120-5552201600020001300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>15. Akonic SA. Estimuladores El&eacute;ctricos - Electrodos EMG -{Internet}-. Buenos Aires (Argentina) -{fecha de acceso:3 junio de 2015}-. Disponible en: <a href="http://www.akonicsa.com/Frames-ES/Prod.html" target="_blank">http://www.akonicsa.com/Frames-ES/Prod.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753144&pid=S0120-5552201600020001300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Biomec. Ciencia en movimiento. Cat&aacute;logo de electromi&oacute;grafo inal&aacute;mbrico de superficie -{Internet}-. Bogot&aacute;, D.C. -{fecha de acceso: 3de junio de 2015}-. p. 1-3. Disponible en: <a href="http://www.biomec.com.co/Analisis-muscular-myon" target="_blank">http://www.biomec.com.co/Analisis-muscular-myon</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753145&pid=S0120-5552201600020001300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Laboratorio de Investigaci&oacute;n. Electromi&oacute;grafo con funda acu&aacute;tica -{Internet}-. Universidad de M&aacute;laga, Facultad de Ciencias de la Salud. M&aacute;laga (Espa&ntilde;a) -{fecha de acceso: 3de junio de 2015}-. Disponible en: <a href="http://www.salud.uma.es/centro/servicios/laboratorio-de-investigacion/586-electromiografo-con-funda-acuatica" target="_blank">http://www.salud.uma.es/centro/servicios/laboratorio-de-investigacion/586-electromiografo-con-funda-acuatica</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753146&pid=S0120-5552201600020001300017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Rodr&iacute;guez EJA, Ocampo JWM, Ortega CAS. Medidores de deformacion por resistencia: galgas extensiom&eacute;tricas. <I>Scientia Et Technica;</I> 2007,1(34):7-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753147&pid=S0120-5552201600020001300018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>19. ADInstruments. Power Lab /35 Series. Owner's Guide -{Internet}-. Australia, Brasil, Europa, Francia, India, Jap&oacute;n, China Oriental, Oriente Medio, Nueva Zelanda; -{fecha de acceso: 3 de junio de 2015}-. p. 1-49. Disponible en: <a href="http://www.adinstruments.com/products/powerlab" target="_blank">http://www.adinstruments.com/products/powerlab</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753149&pid=S0120-5552201600020001300019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. WIM-Systems (Weighing Inspecting and Marking). Celdas de Carga WIM (Sensores de peso). -{Internet}-. Productos. San diego- California, C&aacute;nada, China, Corea; 2002 -{fecha de acceso: 3 de junio de 2015}-. Disponible en: <a href="http://www.wim-systems.com/celdas-de-carga.html" target="_blank">http://www.wim-systems.com/celdas-de-carga.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753150&pid=S0120-5552201600020001300020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Jim&eacute;nez FH, D&iacute;az JG, Montes JV. Dinamometr&iacute;a isocin&eacute;tica. <I>Rehabilitaci&oacute;n</I> 2005, 39(6):288-296. doi: 10.1016/S0048-7120(05)74362-0&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753151&pid=S0120-5552201600020001300021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Ram&iacute;rez T, Manuel H. Torque m&aacute;ximo absoluto e &iacute;ndice convencional isocin&eacute;tico de rodilla en futbolistas profesionales del 2007 al 2012. <I>Rev Med e Investig </I>(M&eacute;xico) 2014, 2:154-62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753152&pid=S0120-5552201600020001300022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>23. Urrialde JAM. Los isocin&eacute;ticos y sus conceptos principales.<I>Fisioterapia</I>, <I>Rev Fisioter 1998; 20</I>(2):2-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753154&pid=S0120-5552201600020001300023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>24. CSMiSolutions. Humac Norm -{Internet}-. Stoughton, MA 02072 UnitedStates of America -{fecha de acceso: 4 de junio de 2015}-. Disponible en: <a href="http://www.csmisolutions.com/products/isokinetic-extremity-systems/humac-norm" target="_blank">http://www.csmisolutions.com/products/isokinetic-extremity-systems/humac-norm</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753156&pid=S0120-5552201600020001300024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25. Dinam&oacute;metros de mano, pierna, espalda y pecho -{Internet}-. Evaluaci&oacute;n / Medici&oacute;n/ Fisiomedica -{fecha de acceso:4 de junio de 2015}-. Disponible en: <a href="http://www.fisiomedica.com/fisioco/productos-y-servicios/clases-de-terapia/evaluacion-medicion/" target="_blank">http://www.fisiomedica.com/fisioco/productos-y-servicios/clases-de-terapia/evaluacion-medicion/</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753157&pid=S0120-5552201600020001300025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Norkin CC, White DJ. <I>Measurement of joint motion: a guide to goniometry</I>. FA Davis. 	4<Sup>th</Sup> ed. Duffield M, editor. Philadelphia: Margaret Biblis; 2009. p. 3-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753158&pid=S0120-5552201600020001300026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>27. De Moya, MFP. La unidad de valoraci&oacute;n del da&ntilde;o corporal del IBV. <I>Revista de biomec&aacute;nica</I> 2002;(37):11-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753160&pid=S0120-5552201600020001300027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>28. Parra-gonz&aacute;lez F, Soler-Garc&iacute;a C. Cat&aacute;logo de Aplicaciones/IBV. <I>Rev. de biomec&aacute;nica</I> (Espa&ntilde;a: Instituto de Biomec&aacute;nica de Valencia) 2002;31-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753162&pid=S0120-5552201600020001300028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>29. Biomec. Ciencia en movimiento. Goni&oacute;metro digital -{Internet}-. Colombia -{fecha de acceso: 4 de junio de 2015}-. Disponible en: <a href="http://www.biomec.com.co/archivos//catalogogoniometrodigitalbiomec186.pdf" target="_blank">http://www.biomec.com.co/archivos//catalogogoniometrodigitalbiomec186.pdf</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753164&pid=S0120-5552201600020001300029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30. Henao Hoyos J, L&oacute;pez J. <I>Goni&oacute;metro digital basado en sensores cinem&aacute;ticos con comunicaci&oacute;n inal&aacute;mbrica en tiempo real.</I> (Disertaci&oacute;n  doctoral). Universidad Pontificia Bolivariana, 2013.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753165&pid=S0120-5552201600020001300030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>31. Moya M, Vera-Garc&iacute;a FJ, L&oacute;pez JL, Aracil A, Reina R, Guti&eacute;rrez O, Paredes J. Nuevas tecnolog&iacute;as aplicadas a la Actividad F&iacute;sica y el Deporte. <I>Revista de la Facultado de Ciencias Sociales y Jur&iacute;dicas de Elche </I>2007;1(2):184-209.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753167&pid=S0120-5552201600020001300031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>32. Bru JS, Vergara M, Bou N J, Aguilar MM, &amp; Gonz&aacute;lez AP. Medici&oacute;n del movimiento de todos los segmentos de la mano mediante videogrametr&iacute;a. XIX Congreso Nacional de Ingenier&iacute;a Mec&aacute;nica. Espa&ntilde;a. p. 1-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753169&pid=S0120-5552201600020001300032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>33. Kinovea. Tutorial de Kinovea -{Internet}-. Plan Integral de Educaci&oacute;n, Digital Direcci&oacute;n Operativa de Incorporaci&oacute;n de Tecnolog&iacute;as (InTec). Buenos Aires: Ministerio de Educaci&oacute;n; -{fecha de acceso:15 de mayo de 2015}-. p. 1-33. Available from: <a href="http://www.formadores.org/vinculostutorialkinovea.pdf" target="_blank">http://www.formadores.org/vinculostutorialkinovea.pdf</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753171&pid=S0120-5552201600020001300033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>34. Vilches Ant&atilde;o DG. <I>Juegos serios, evaluaci&oacute;n de tecnolog&iacute;as y &aacute;mbitos de aplicaci&oacute;n.</I> (Disertaci&oacute;n doctoral, Facultad de Inform&aacute;tica). Universidad Nacional de la Plata, 2014.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753172&pid=S0120-5552201600020001300034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>35. Mu&ntilde;oz Cardona JE, Henao Gallo OA, L&oacute;pez Herrera JF. Sistema de Rehabilitaci&oacute;n basado en el Uso de An&aacute;lisis Biomec&aacute;nico y Videojuegos mediante el Sensor Kinect. <I>Rev. Tecno. L&oacute;gicas</I> (Pereira, Colombia) 2013 (edici&oacute;n especial);43-54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753174&pid=S0120-5552201600020001300035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      ]]></body>
<body><![CDATA[<!-- ref --><p>36. Miller T, Conditioning Association. <I>NSCA's </I>Guide to Tests and Assessments. <I>Human Kinetics</I> 2012; (1):295-315.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753176&pid=S0120-5552201600020001300036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>37. Bricot B. Postura normal y posturapatol&oacute;gica. <I>Revi IPP</I> 2008;2:1-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753178&pid=S0120-5552201600020001300037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>38. Petrocci KE, C&aacute;rdenas-Sandoval RP. La medici&oacute;n del control postural con estabilometr&iacute;a - una revisi&oacute;n documental. <I>REV COL REH </I>2011;10(1692 - 1879):16-24.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753180&pid=S0120-5552201600020001300038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>39. S&aacute;nchez SMG. Influencia de la pr&aacute;ctica deportiva en la integraci&oacute;n sensorial en ni&ntilde;os: Evaluaci&oacute;n estabilom&eacute;trica. Facultad de Ciencias de la Salud, Departamento de Anatom&iacute;a y Embriolog&iacute;a Humana, Universidad Rey Juan Carlos; 2013.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753182&pid=S0120-5552201600020001300039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>40. Falls HC. Metodolog&iacute;a para la Interpretaci&oacute;n Cuantitativa del Movimiento Articular. <I>InfoMED (Cuba): Inform&aacute;tica en salud. </I>2009;1: 1-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753184&pid=S0120-5552201600020001300040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      ]]></body>
<body><![CDATA[<!-- ref --><p>41. Villa-Moreno A, Guti&eacute;rrez-Guti&eacute;rrez E, P&eacute;rez-Moreno JC. Consideraciones para el an&aacute;lisis de la marcha humana. T&eacute;cnicas de videogrametr&iacute;a, electromiograf&iacute;a y dinamometr&iacute;a. <I>Revista Ingenier&iacute;a Biom&eacute;dica</I> 2008; 3(2):16-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753186&pid=S0120-5552201600020001300041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>42. Ros&aacute;rio JLP. A review of the utilization of baropodometry in postural assessment. <I>Journal of bodywork and movement therapies</I> 2014;18(2):215-219. doi: 10.1016/j.jbmt.2013.05.016&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753188&pid=S0120-5552201600020001300042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>43. Yabar LF, Garc&iacute;a DO, C&oacute;ndor C. Villavicencia, E. Estudio para el dise&ntilde;o de un sistema baropodom&eacute;trico electr&oacute;nico. Lima (Per&uacute;): XII Jornadas Internacionales de Ingenier&iacute;a Cl&iacute;nica y Tecnolog&iacute;a M&eacute;dica; 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753189&pid=S0120-5552201600020001300043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>44. Desrosiers J, Rochette A, Corriveau H. Validation of a new lower-extremity motor coordination test. <I>Archives of physical medicine and rehabilitation</I>, 2005, <I>86</I>(5), 993-998. doi: 10.1016/j.apmr.2004.11.007&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753191&pid=S0120-5552201600020001300044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>45. &Aacute;lvarez JLH, Curiel DA. <I>La evaluaci&oacute;n en educaci&oacute;n f&iacute;sica: Investigaci&oacute;n y pr&aacute;ctica en el &aacute;mbito escolar</I>,  Grao; 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753192&pid=S0120-5552201600020001300045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>46. Mendoza AIA, Santamaria TJB, Urrego VG, Restrepo JPR, Garc&iacute;a MCZ. Marcha: descripci&oacute;n, m&eacute;todos, herramientas de evaluaci&oacute;n y par&aacute;metros de normalidad reportados en la literatura.(Gait: description, methods, assessment tools and normality parameters reported in the literature). <I>CES Movimiento y Salud</I> 2013; 1(1):29-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753194&pid=S0120-5552201600020001300046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      ]]></body>
<body><![CDATA[<!-- ref --><p>47. Mart&iacute;nez Ram&iacute;rez A, Irujo Espinosa M, Larri&oacute;n JL, G&oacute;mez Fern&aacute;ndez M, Izquierdo Red&iacute;n M. Valoraci&oacute;n de la capacidad funcional en el &aacute;mbito domiciliario y en la cl&iacute;nica. Nuevas posibilidades de aplicaci&oacute;n de la acelerometr&iacute;a para la valoraci&oacute;n de la marcha, equilibrio y potencia muscular en personas mayores. <I>Anales del Sistema Sanitario de Navarra </I>2008;31(2):159-170.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753196&pid=S0120-5552201600020001300047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>48. MoCap Captura de movimientos. Captura de movimientos electromec&aacute;nica -{Internet}-. -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://sabia.tic.udc.es/gc/Contenidos" target="_blank">http://sabia.tic.udc.es/gc/Contenidos</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753198&pid=S0120-5552201600020001300048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>49. Olaya AFR. Sistema rob&oacute;tico multimodal para an&aacute;lisis y estudios en biomec&aacute;nica, movimiento humano y control neuromotor. Madrid: Universidad Carlos III, Departamento Ingenier&iacute;a de Sistemas y Autom&aacute;tica, 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753199&pid=S0120-5552201600020001300049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>      <!-- ref --><p>50. Sensor Medica. Plataformas freeMed&reg; -{Internet}-. Argentina, Romania,Brazi,Greece, Venezuela, Australia,M&eacute;xico, New Zealand, Spain, South Africa, France, Portugal,Poland -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.sensormedica.com/site/es/productos/plataformas-freemed" target="_blank">http://www.sensormedica.com/site/es/productos/plataformas-freemed</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753201&pid=S0120-5552201600020001300050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>51. Medicapteurs. Podiatry stabilometry rehabilitation -{Internet}- -{fecha de acceso: 20 de junio de 2015}-. Available from: <a href="http://www.medicapteurs.com/" target="_blank">http://www.medicapteurs.com/</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753202&pid=S0120-5552201600020001300051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>52. Shop Nintendo /Nintendo Online Store. Wii remote -{Internet}-. Disponible en: <a href="https://store.nintendo.com/ng3/browse/productDetailColorSizePicker.jsp?productId=prod150198" target="_blank">https://store.nintendo.com/ng3/browse/productDetailColorSizePicker.jsp?productId=prod150198</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753203&pid=S0120-5552201600020001300052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>53. PhaseSpace. Motion Capture -{Internet}- -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.phasespace.com/impulse-motion-capture.html" target="_blank">http://www.phasespace.com/impulse-motion-capture.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753204&pid=S0120-5552201600020001300053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>54. VICON. Camera Systems -{Internet}- -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.vicon.com/products/camera-systems" target="_blank">http://www.vicon.com/products/camera-systems</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753205&pid=S0120-5552201600020001300054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>55. Aplicaciones Android en Google play. Goni&oacute;metro Pro Gratuito -{Internet}- -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="https://play.google.com/store/apps/details?id=com.FiveFufFive.GoniometerProPreviewAndroid&amp;hl=es_419" target="_blank">https://play.google.com/store/apps/details?id=com.FiveFufFive.GoniometerProPreviewAndroid&amp;hl=es_419</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753206&pid=S0120-5552201600020001300055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>56. Isocin&eacute;tico Humac Norm -{Internet}-. SANRO Electromedicina -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.sanro.com/producto/175_Isocinetico_Humac_Norm.html" target="_blank">http://www.sanro.com/producto/175_Isocinetico_Humac_Norm.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753207&pid=S0120-5552201600020001300056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>57. HBM. Galgas extensom&eacute;tricas -{Internet}-. Espa&ntilde;a -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.hbm.com/es/menu/productos/galgas-extensometricas/" target="_blank">http://www.hbm.com/es/menu/productos/galgas-extensometricas/</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753208&pid=S0120-5552201600020001300057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>58. Direct Industry. Galgas extensiometricas -{Internet}-. Francia -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://www.directindustry.es/fabricante-industrial/galga-extensiometrica-73369.html" target="_blank">http://www.directindustry.es/fabricante-industrial/galga-extensiometrica-73369.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753209&pid=S0120-5552201600020001300058&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>59. Electromi&oacute;grafos -{Internet}-. Cism&eacute;dica. Disponible en: <a href="http://www.cismedica.com/neurologia" target="_blank">http://www.cismedica.com/neurologia</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753210&pid=S0120-5552201600020001300059&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>60. FreeStep -{Internet}-. Sensor M&eacute;dica. Argentina, Romania, Brazi, Greece, Venezuela, Australia, Mexico, New Zealand,Spain, South Africa, France, Portugal, Poland -{fecha de acceso:20 de junio de 2015}-. Disponible en: <a href="http://www.sensormedica.com/site/es/software/software-freestep-esp" target="_blank">http://www.sensormedica.com/site/es/software/software-freestep-esp</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753211&pid=S0120-5552201600020001300060&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>61. Easytech isocin&eacute;tica -{Internet}-. Meical EXPO -{fecha de acceso: 4 de junio de 2015}-. Disponible en: <a href="http://pdf.medicalexpo.es/pdf/easytech/isocinetica/68295-73864.html" target="_blank">http://pdf.medicalexpo.es/pdf/easytech/isocinetica/68295-73864.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753212&pid=S0120-5552201600020001300061&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>62. Arraya Equipamiento M&eacute;dico. BTS FREEEMG 300 -{Internet}-. Disponible en: <a href="http://arrayamed.com/sp/producto/freeemg_300.html" target="_blank">http://arrayamed.com/sp/producto/freeemg_300.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753213&pid=S0120-5552201600020001300062&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>63. MoCap captura de movimientos. Captura de movimientos electromec&aacute;nica -{Internet}- -{fecha de acceso: 20 de junio de 2015}-. Disponible en: <a href="http://sabia.tic.udc.es/gc/Contenidos adicionales/trabajos/Peliculas/Mocap/tecnol.htm" target="_blank">http://sabia.tic.udc.es/gc/Contenidos adicionales/trabajos/Peliculas/Mocap/tecnol.htm</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753214&pid=S0120-5552201600020001300063&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>64. Corporation S. Magnetoscopio grabador digital -{Internet}-. Departamento de Formaci&oacute;n y Publicaciones T&eacute;cnicas. Sony Espa&ntilde;a S. A. 1999 -{fecha de acceso: 26 de mayo de 2015}-. Disponible en: <a href="http://webspersoais.usc.es/export/sites/default/persoais/ruben.garcia/Descargas/MANUALDEINSTRUCCIONSDOMAGNETOSCOPIOSONYDSR-20P.pdf" target="_blank">http://webspersoais.usc.es/export/sites/default/persoais/ruben.garcia/Descargas/MANUALDEINSTRUCCIONSDOMAGNETOSCOPIOSONYDSR-20P.pdf</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753215&pid=S0120-5552201600020001300064&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>65. R&iacute;os MM, Chac&oacute;n EM, Fern&aacute;ndez AC, Guill&eacute;n EO. Termograf&iacute;a infrarroja y el estudio de riesgos de lesiones m&uacute;sculo esquel&eacute;ticas. <I>Revista Ingenier&iacute;a Industrial</I> 2011;10(1): 55-67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753216&pid=S0120-5552201600020001300065&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>      <!-- ref --><p>66. Braidot A, Bisheimer M, Di Paolo J, Verde O. Desarrollo de un Equipo para el Registro de Variables Biomec&aacute;nicas Mediante Ultrasonido. XII Jornadas Internacionales de Ingenier&iacute;a Cl&iacute;nica y Tecnolog&iacute;a M&eacute;dica. Argentina; 2008.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3753218&pid=S0120-5552201600020001300066&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>    </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cifuentes-Piñeros]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Boada-Mojica]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Candia-Ospina]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Martínez-Segura]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Maldonado- Ramírez]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Manual de procedimientos para la rehabilitación y reincorporación ocupacional de los trabajadores en el sistema general de riesgos profesionales]]></source>
<year>2010</year>
<edition>3ªed</edition>
<publisher-name><![CDATA[República de Colombia: Ministerio de la Protección Social Dirección General de Riesgos Profesionales]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<source><![CDATA[Decreto 1072 de 2015. Por medio del cual se expide el Decreto Único Reglamentario del Sector Trabajo]]></source>
<year>2015</year>
<publisher-name><![CDATA[República de Colombia: Ministerio de Trabajo]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gutiérrez-Strauss]]></surname>
</name>
</person-group>
<source><![CDATA[Guía técnica para el análisis de exposición a factores de riesgo ocupacional]]></source>
<year>2011</year>
<publisher-name><![CDATA[República de Colombia: Ministerio de la Protección Social]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pardo]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Chamorro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Monitorización del dolor: Recomendaciones del grupo de trabajo de analgesia y sedación de la SEMICYUC]]></article-title>
<source><![CDATA[Medicina intensiva]]></source>
<year>2006</year>
<volume>30</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>379-385</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Durán F]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Agudelo]]></surname>
<given-names><![CDATA[LHL]]></given-names>
</name>
</person-group>
<source><![CDATA[Rehabilitación en salud]]></source>
<year>2008</year>
<page-range>39-74</page-range><publisher-name><![CDATA[Universidad de Antioquia]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[González-Badillo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gorostiaga-Ayestarán]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Fundamentos del entrenamiento de la fuerza: Aplicación al alto rendimiento deportivo]]></source>
<year>2002</year>
<edition>3ª ed.</edition>
<page-range>1-63</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[INDE Publicaciones]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hislop]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Montgomery]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Pruebas funcionales musculares]]></source>
<year>2002</year>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Marban]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kendall]]></surname>
<given-names><![CDATA[FP]]></given-names>
</name>
<name>
<surname><![CDATA[Kendall]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Geise]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[McIntyre]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Anthony]]></surname>
<given-names><![CDATA[WM]]></given-names>
</name>
</person-group>
<source><![CDATA[Pruebas Funcionales. Postura y Dolor]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Luca]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of surface electromyography in biomechanics]]></article-title>
<source><![CDATA[Journal of applied biomechanics]]></source>
<year>1997</year>
<volume>13</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>135-163</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sanabria J]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Archila]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Detección y análisis de movimiento usando visión artificial]]></article-title>
<source><![CDATA[Scientia Et Technica]]></source>
<year>2011</year>
<volume>3</volume>
<numero>49</numero>
<issue>49</issue>
<page-range>180-188</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Álvarez-Fiallo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Santos-Anzorandía]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Medina-Herrera]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Implementación de la electromiografía cuantitativa para el estudio de las enfermedades neuromusculares]]></article-title>
<source><![CDATA[Revista Cubana de Medicina Militar]]></source>
<year>2005</year>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Canal]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of wavelet and short time Fourier transform methods in the analysis of EMG signals]]></article-title>
<source><![CDATA[Journal of medical systems]]></source>
<year>2010</year>
<volume>34</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>91-94</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santafé]]></surname>
<given-names><![CDATA[YE]]></given-names>
</name>
<name>
<surname><![CDATA[Chaparro]]></surname>
<given-names><![CDATA[BD]]></given-names>
</name>
<name>
<surname><![CDATA[Franco]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Detección de patrones característicos con transformadas wavelet en señales electromiográficas del cuádriceps]]></article-title>
<source><![CDATA[Revista Colombiana de Tecnologias de Avanzada (RCTA)]]></source>
<year>2013</year>
<volume>2</volume>
<numero>20</numero>
<issue>20</issue>
<page-range>151-8</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Calvo]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
</person-group>
<source><![CDATA[El laboratorio de biomecánica como ayuda en el diseño del puesto de trabajo]]></source>
<year>2005</year>
<publisher-loc><![CDATA[Zaragoza ]]></publisher-loc>
<publisher-name><![CDATA[INERMAP. Área de Biomecánica]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Akonic]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
</person-group>
<source><![CDATA[Estimuladores Eléctricos - Electrodos EMG]]></source>
<year></year>
<publisher-loc><![CDATA[Buenos Aires ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="">
<collab>Biomec</collab>
<source><![CDATA[Ciencia en movimiento. Catálogo de electromiógrafo inalámbrico de superficie]]></source>
<year></year>
<page-range>1-3</page-range><page-range>http://www.biomec.com.co/Analisis-muscular-myon</page-range><publisher-loc><![CDATA[Bogotá^eD.C D.C]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="book">
<collab>Laboratorio de Investigación</collab>
<source><![CDATA[Electromiógrafo con funda acuática]]></source>
<year></year>
<publisher-loc><![CDATA[Málaga ]]></publisher-loc>
<publisher-name><![CDATA[Universidad de Málaga, Facultad de Ciencias de la Salud]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[EJA]]></given-names>
</name>
<name>
<surname><![CDATA[Ocampo]]></surname>
<given-names><![CDATA[JWM]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[CAS]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Medidores de deformacion por resistencia: galgas extensiométricas]]></article-title>
<source><![CDATA[Scientia Et Technica]]></source>
<year>2007</year>
<volume>1</volume>
<numero>34</numero>
<issue>34</issue>
<page-range>7-11</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="">
<source><![CDATA[ADInstruments. Power Lab /35 Series. Owner's Guide]]></source>
<year></year>
<page-range>1-49</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="">
<collab>WIM-Systems (Weighing Inspecting and Marking)</collab>
<source><![CDATA[Celdas de Carga WIM (Sensores de peso)]]></source>
<year>2002</year>
<publisher-loc><![CDATA[San diego^eCalifornia California]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiménez]]></surname>
<given-names><![CDATA[FH]]></given-names>
</name>
<name>
<surname><![CDATA[Díaz]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Montes]]></surname>
<given-names><![CDATA[JV]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Dinamometría isocinética]]></article-title>
<source><![CDATA[Rehabilitación]]></source>
<year>2005</year>
<volume>39</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>288-296</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Manuel]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Torque máximo absoluto e índice convencional isocinético de rodilla en futbolistas profesionales del 2007 al 2012]]></article-title>
<source><![CDATA[Rev Med e Investig]]></source>
<year>2014</year>
<volume>2</volume>
<page-range>154-62</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Urrialde]]></surname>
<given-names><![CDATA[JAM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Los isocinéticos y sus conceptos principales]]></article-title>
<source><![CDATA[Fisioterapia, Rev Fisioter]]></source>
<year>1998</year>
<volume>20</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>2-7</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="book">
<source><![CDATA[CSMiSolutions. Humac Norm &#91;Internet&#93;]]></source>
<year></year>
<publisher-loc><![CDATA[Stoughton^eMA MA]]></publisher-loc>
<publisher-name><![CDATA[UnitedStates of America]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="">
<source><![CDATA[Dinamómetros de mano, pierna, espalda y pecho]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norkin]]></surname>
<given-names><![CDATA[CC]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Davis]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<source><![CDATA[Measurement of joint motion: a guide to goniometry]]></source>
<year>2009</year>
<edition>4th ed</edition>
<page-range>3-15</page-range><publisher-loc><![CDATA[Philadelphia ]]></publisher-loc>
<publisher-name><![CDATA[Margaret Biblis]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Moya]]></surname>
<given-names><![CDATA[MFP]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La unidad de valoración del daño corporal del IBV]]></article-title>
<source><![CDATA[Revista de biomecánica]]></source>
<year>2002</year>
<numero>37</numero>
<issue>37</issue>
<page-range>11-13</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Parra-gonzález]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Soler-García]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Catálogo de Aplicaciones/IBV]]></article-title>
<source><![CDATA[Rev. de biomecánica]]></source>
<year>2002</year>
<page-range>31-5</page-range><publisher-name><![CDATA[Instituto de Biomecánica de Valencia]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="">
<collab>Biomec</collab>
<source><![CDATA[Ciencia en movimiento. Goniómetro digital]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henao Hoyos]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Goniómetro digital basado en sensores cinemáticos con comunicación inalámbrica en tiempo real]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moya]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Vera-García]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Aracil]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Reina]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Paredes]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Nuevas tecnologías aplicadas a la Actividad Física y el Deporte]]></article-title>
<source><![CDATA[Revista de la Facultado de Ciencias Sociales y Jurídicas de Elche]]></source>
<year>2007</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>184-209</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bru]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Vergara]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bou N]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Aguilar]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
</person-group>
<source><![CDATA[Medición del movimiento de todos los segmentos de la mano mediante videogrametría]]></source>
<year></year>
<conf-name><![CDATA[XIX Congreso Nacional de Ingeniería Mecánica]]></conf-name>
<conf-loc> </conf-loc>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="book">
<collab>Kinovea. Tutorial de Kinovea</collab>
<source><![CDATA[Plan Integral de Educación, Digital Dirección Operativa de Incorporación de Tecnologías (InTec)]]></source>
<year></year>
<page-range>1-33</page-range><publisher-loc><![CDATA[Buenos Aires ]]></publisher-loc>
<publisher-name><![CDATA[Ministerio de Educación]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vilches Antão]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
</person-group>
<source><![CDATA[Juegos serios, evaluación de tecnologías y ámbitos de aplicación]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muñoz Cardona]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Henao Gallo]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[López Herrera]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistema de Rehabilitación basado en el Uso de Análisis Biomecánico y Videojuegos mediante el Sensor Kinect]]></article-title>
<source><![CDATA[Rev. Tecno. Lógicas]]></source>
<year>2013</year>
<page-range>43-54</page-range><publisher-loc><![CDATA[Pereira ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Conditioning Association. NSCA's Guide to Tests and Assessments]]></article-title>
<source><![CDATA[Human Kinetics]]></source>
<year>2012</year>
<numero>1</numero>
<issue>1</issue>
<page-range>295-315</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bricot]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Postura normal y posturapatológica]]></article-title>
<source><![CDATA[Revi IPP]]></source>
<year>2008</year>
<volume>2</volume>
<page-range>1-13</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Petrocci]]></surname>
<given-names><![CDATA[KE]]></given-names>
</name>
<name>
<surname><![CDATA[Cárdenas-Sandoval]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La medición del control postural con estabilometría - una revisión documental]]></article-title>
<source><![CDATA[REV COL REH]]></source>
<year>2011</year>
<volume>10</volume>
<numero>1692 - 1879</numero>
<issue>1692 - 1879</issue>
<page-range>16-24</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[SMG]]></given-names>
</name>
</person-group>
<source><![CDATA[Influencia de la práctica deportiva en la integración sensorial en niños: Evaluación estabilométrica]]></source>
<year>2013</year>
<publisher-name><![CDATA[Facultad de Ciencias de la Salud, Departamento de Anatomía y Embriología Humana, Universidad Rey Juan Carlos]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Falls]]></surname>
<given-names><![CDATA[HC]]></given-names>
</name>
</person-group>
<source><![CDATA[Metodología para la Interpretación Cuantitativa del Movimiento Articular]]></source>
<year>2009</year>
<volume>1</volume>
<page-range>1-7</page-range><publisher-name><![CDATA[InfoMED (Cuba): Informática en salud]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Villa-Moreno]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez-Gutiérrez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez-Moreno]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Consideraciones para el análisis de la marcha humana. Técnicas de videogrametría, electromiografía y dinamometría]]></article-title>
<source><![CDATA[Revista Ingeniería Biomédica]]></source>
<year>2008</year>
<volume>3</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>16-26</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosário]]></surname>
<given-names><![CDATA[JLP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A review of the utilization of baropodometry in postural assessment]]></article-title>
<source><![CDATA[Journal of bodywork and movement therapies]]></source>
<year>2014</year>
<volume>18</volume>
<numero>2)</numero>
<issue>2)</issue>
<page-range>215-219</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yabar]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[DO]]></given-names>
</name>
<name>
<surname><![CDATA[Cóndor]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Villavicencia]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio para el diseño de un sistema baropodométrico electrónico]]></source>
<year></year>
<conf-name><![CDATA[ Lima (Perú): XII Jornadas Internacionales de Ingeniería Clínica y Tecnología Médica]]></conf-name>
<conf-date>2008</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Desrosiers]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rochette]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Corriveau]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Validation of a new lower-extremity motor coordination test]]></article-title>
<source><![CDATA[Archives of physical medicine and rehabilitation]]></source>
<year>2005</year>
<volume>86</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>993-998</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Álvarez]]></surname>
<given-names><![CDATA[JLH]]></given-names>
</name>
<name>
<surname><![CDATA[Curiel]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<source><![CDATA[La evaluación en educación física: Investigación y práctica en el ámbito escolar]]></source>
<year>2004</year>
<publisher-name><![CDATA[Grao]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mendoza]]></surname>
<given-names><![CDATA[AIA]]></given-names>
</name>
<name>
<surname><![CDATA[Santamaria]]></surname>
<given-names><![CDATA[TJB]]></given-names>
</name>
<name>
<surname><![CDATA[Urrego]]></surname>
<given-names><![CDATA[VG]]></given-names>
</name>
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[JPR]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[MCZ]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Marcha: descripción, métodos, herramientas de evaluación y parámetros de normalidad reportados en la literatura.(Gait: description, methods, assessment tools and normality parameters reported in the literature)]]></article-title>
<source><![CDATA[CES Movimiento y Salud]]></source>
<year>2013</year>
<volume>1</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-43</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez Ramírez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Irujo Espinosa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Larrión]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez Fernández]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Izquierdo Redín]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Valoración de la capacidad funcional en el ámbito domiciliario y en la clínica. Nuevas posibilidades de aplicación de la acelerometría para la valoración de la marcha, equilibrio y potencia muscular en personas mayores]]></article-title>
<source><![CDATA[Anales del Sistema Sanitario de Navarra]]></source>
<year>2008</year>
<volume>31</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>159-170</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="">
<collab>MoCap Captura de movimientos</collab>
<source><![CDATA[Captura de movimientos electromecánica]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Olaya]]></surname>
<given-names><![CDATA[AFR]]></given-names>
</name>
</person-group>
<source><![CDATA[Sistema robótico multimodal para análisis y estudios en biomecánica, movimiento humano y control neuromotor]]></source>
<year>2008</year>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Universidad Carlos III, Departamento Ingeniería de Sistemas y Automática]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="">
<source><![CDATA[Sensor Medica. Plataformas freeMed®]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="">
<source><![CDATA[Medicapteurs. Podiatry stabilometry rehabilitation]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="">
<source><![CDATA[Shop Nintendo /Nintendo Online Store. Wii remote]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="">
<source><![CDATA[PhaseSpace. Motion Capture]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="">
<source><![CDATA[VICON. Camera Systems]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="">
<source><![CDATA[Aplicaciones Android en Google play. Goniómetro Pro Gratuito]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="">
<source><![CDATA[Isocinético Humac Norm]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="">
<source><![CDATA[HBM. Galgas extensométricas]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B58">
<label>58</label><nlm-citation citation-type="">
<source><![CDATA[Direct Industry. Galgas extensiometricas]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B59">
<label>59</label><nlm-citation citation-type="">
<source><![CDATA[Electromiógrafos]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B60">
<label>60</label><nlm-citation citation-type="">
<collab>FreeStep</collab>
<source><![CDATA[Sensor Médica. Argentina, Romania, Brazi, Greece, Venezuela, Australia, Mexico, New Zealand,Spain, South Africa, France, Portugal, Poland]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B61">
<label>61</label><nlm-citation citation-type="">
<source><![CDATA[Easytech isocinética]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B62">
<label>62</label><nlm-citation citation-type="">
<source><![CDATA[Arraya Equipamiento Médico. BTS FREEEMG 300]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B63">
<label>63</label><nlm-citation citation-type="">
<source><![CDATA[MoCap captura de movimientos. Captura de movimientos electromecánica]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B64">
<label>64</label><nlm-citation citation-type="book">
<collab>Corporation S</collab>
<source><![CDATA[Magnetoscopio grabador digital]]></source>
<year>1999</year>
<publisher-name><![CDATA[Departamento de Formación y Publicaciones Técnicas. Sony España S. A]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B65">
<label>65</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ríos]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Chacón]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Guillén]]></surname>
<given-names><![CDATA[EO]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Termografía infrarroja y el estudio de riesgos de lesiones músculo esqueléticas]]></article-title>
<source><![CDATA[Revista Ingeniería Industrial]]></source>
<year>2011</year>
<volume>10</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>55-67</page-range></nlm-citation>
</ref>
<ref id="B66">
<label>66</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Braidot]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bisheimer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Di Paolo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Verde]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<source><![CDATA[Desarrollo de un Equipo para el Registro de Variables Biomecánicas Mediante Ultrasonido. XII Jornadas Internacionales de Ingeniería Clínica y Tecnología Médica]]></source>
<year>2008</year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
