<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2011000100006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab®]]></article-title>
<article-title xml:lang="en"><![CDATA[Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Caparroso Pérez]]></surname>
<given-names><![CDATA[Carlos Bernardo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Marín Muñoz]]></surname>
<given-names><![CDATA[Diana Virginia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Echavarría Velásquez]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Antioquia Facultad de Ingeniería de Materiales, ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<volume>22</volume>
<numero>2</numero>
<fpage>186</fpage>
<lpage>197</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2011000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2011000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2011000100006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: el objetivo fue determinar ex vivo la adaptación marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab®. MÉTODOS: se tomaron 15 pilares protésicos prefabricados contorneados de implantes divididos en tres grupos. Se fabricaron estructuras en aleación noble Pd-Au (control), Procera All Zircon® y Cerec In-lab YZ cubes®. Para evaluar la adaptación marginal se tomaron ocho medidas en la circunferencia del pilar protésico, tomando la distancia entre el borde de la estructura y el pilar. Para determinar el ajuste interno se hicieron ocho medidas desde la superficie externa del pilar a la superficie interna de la restauración. Las mediciones fueron hechas por microscopia óptica (50X). Los datos obtenidos fueron analizados por medio del análisis de varianza de una vía, la t de Student y prueba de Dunnett. RESULTADOS: el promedio de adaptación marginal del grupo control fue 18,24 &micro;m &plusmn;4,81; el grupo Procera® 21,62 &micro;m &plusmn;12,15 y el grupo Cerec In-lab® de 47,34 &micro;m &plusmn;17,72. El promedio de ajuste interno para las estructuras Pd-Au fue 34,60 &micro;m &plusmn;16,16; Procera® 118,67 &micro;m &plusmn;50,84 y el Cerec In-lab® 65,62 &micro;m &plusmn;25,80. CONCLUSIONES: los valores de adaptación marginal de las estructuras de aleación metálica y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab® están entre los valores clínicamente aceptables. Las medidas de ajuste interno obtenidos para los grupos aleación metálica y Cerec® se encuentran dentro del rango reportado en la literatura. Mientras que el promedio obtenido para el grupo Procera® 118,67 &micro;m &plusmn;50,84, aunque se acercó al límite máximo de ajuste interno reportado en la literatura, no se evidenció diferencia estadísticamente significativa con el sistema Cerec In-lab®.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. METHODS: fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment&sbquo;s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student&sbquo;s paired t test and Dunnett&sbquo;test. RESULTS: marginal adaptation mean for the control group was 18.24&plusmn;4.81&micro;m and Procera® 21.62 &micro;m &plusmn;12.15 &micro;m, while the average for Cerec In-lab® was 47.34 &micro;m &plusmn;17.72 &micro;m. The internal fit for the control group was 34,60 &micro;m &plusmn;16.16 &micro;m and Procera® group was of 118.67 &micro;m &plusmn;50.84 &micro;m in average and Cerec In-lab® 65.62 &micro;m &plusmn;25.80 &micro;m. CONCLUSION: the metal alloy and zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera® group was 118.67 &micro;m &plusmn;50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[zirconia-ytria Procera]]></kwd>
<kwd lng="es"><![CDATA[zirconia ytria Cerec in-Lab]]></kwd>
<kwd lng="es"><![CDATA[CAD/CAM]]></kwd>
<kwd lng="es"><![CDATA[adaptación marginal]]></kwd>
<kwd lng="es"><![CDATA[ajuste interno]]></kwd>
<kwd lng="en"><![CDATA[zirconia-ytria Procera]]></kwd>
<kwd lng="en"><![CDATA[zirconia ytria Cerec in-Lab]]></kwd>
<kwd lng="en"><![CDATA[CAD/CAM]]></kwd>
<kwd lng="en"><![CDATA[marginal adaptation]]></kwd>
<kwd lng="en"><![CDATA[internal adjustment]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Adaptaci&oacute;n marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera<sup><sup>&reg;</sup></sup> y Cerec in-Lab<sup><sup>&reg;</sup></sup>.<sup>1</sup></b></font></p>          <p>&nbsp;</p>           <p align="center"><font size="3" face="Verdana"><b>Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera<sup><sup>&reg;</sup></sup> and Cerec in-Lab<sup><sup>&reg;</sup></sup> CAD/CAM systems</b></font></p>           <p>&nbsp;</p>          <p>&nbsp;</p>           <p><b>Carlos Bernardo Caparroso P&eacute;rez<sup>2</sup>; Diana Virginia Mar&iacute;n Mu&ntilde;oz<sup>3</sup>; Alejandro Echavarr&iacute;a Vel&aacute;squez<sup>4</sup></b></p>      <p><sup>1</sup> Art&iacute;culo derivado de una investigaci&oacute;n hecha como requisito parcial para optar al t&iacute;tulo de Especialista en Odontolog&iacute;a Integral del Adulto con &eacute;nfasis en Prostodoncia, Facultad de Odontolog&iacute;a, de uno de los coautores. Investigaci&oacute;n financiada por el Comit&eacute; para el Desarrollo de la Investigaci&oacute;n (CODI), la Facultad de Ingenier&iacute;a y la Facultad de Odontolog&iacute;a de la Universidad de Antioquia. Investigaci&oacute;n con la participaci&oacute;n del Grupo de Corrosi&oacute;n de la Facultad de Ingenier&iacute;a y el Grupo de Biomateriales de la Facultad de Odontolog&iacute;a, Universidad de Antioquia    ]]></body>
<body><![CDATA[<br>  <sup>2</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto con &eacute;nfasis en Prostodoncia, mag&iacute;ster en Educaci&oacute;n Superior, profesor asistente, Facultad de Odontolog&iacute;a, Universidad de Antioquia. Correo electr&oacute;nico: <a href="mailto:ccaparroso@gmail.com">ccaparroso@gmail.com</a>    <br>      <sup>3</sup> Estudiante de posgrado de Odontolog&iacute;a Integral del Adulto con &eacute;nfasis en Prostodoncia, Facultad de Odontolog&iacute;a, Universidad de Antioquia    <br>  <sup>4</sup> Ingeniero metal&uacute;rgico, especialista, M.Sc., Ph.D., profesor vinculado, Facultad de Ingenier&iacute;a de Materiales, Universidad de Antioquia</p>       <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> el objetivo fue determinar ex vivo la adaptaci&oacute;n marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera<sup><sup>&reg;</sup></sup> y Cerec In-lab<sup><sup>&reg;</sup></sup>.    <br>  <b>M&Eacute;TODOS:</b> se tomaron 15 pilares prot&eacute;sicos prefabricados contorneados de implantes divididos en tres grupos. Se fabricaron estructuras en aleaci&oacute;n noble Pd-Au (control), Procera All Zircon<sup><sup>&reg;</sup></sup> y Cerec In-lab YZ cubes<sup><sup>&reg;</sup></sup>. Para evaluar la adaptaci&oacute;n marginal se tomaron ocho medidas en la circunferencia del pilar prot&eacute;sico, tomando la distancia entre el borde de la estructura y el pilar. Para determinar el ajuste interno se hicieron ocho medidas desde la superficie externa del pilar a la superficie interna de la restauraci&oacute;n. Las mediciones fueron hechas por microscopia &oacute;ptica (50X). Los datos obtenidos fueron analizados por medio del an&aacute;lisis de varianza de una v&iacute;a, la t de Student y prueba de Dunnett.    <br>  <b>RESULTADOS:</b> el promedio de adaptaci&oacute;n marginal del grupo control fue 18,24 &micro;m &plusmn;4,81; el grupo Procera<sup><sup>&reg;</sup></sup> 21,62 &micro;m &plusmn;12,15 y el grupo Cerec In-lab<sup><sup>&reg;</sup></sup> de 47,34 &micro;m &plusmn;17,72. El promedio de ajuste interno para las estructuras Pd-Au fue 34,60 &micro;m &plusmn;16,16; Procera<sup><sup>&reg;</sup></sup> 118,67 &micro;m &plusmn;50,84 y el Cerec In-lab<sup><sup>&reg;</sup></sup> 65,62 &micro;m &plusmn;25,80.    <br>  <b>CONCLUSIONES:</b> los valores de adaptaci&oacute;n marginal de las estructuras de aleaci&oacute;n met&aacute;lica y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera<sup><sup>&reg;</sup></sup> y Cerec In-lab<sup><sup>&reg;</sup></sup> est&aacute;n entre los valores cl&iacute;nicamente aceptables. Las medidas de ajuste interno obtenidos para los grupos aleaci&oacute;n met&aacute;lica y Cerec<sup><sup>&reg;</sup></sup> se encuentran dentro del rango reportado en la literatura. Mientras que el promedio obtenido para el grupo Procera<sup><sup>&reg;</sup></sup> 118,67 &micro;m &plusmn;50,84, aunque se acerc&oacute; al l&iacute;mite m&aacute;ximo de ajuste interno reportado en la literatura, no se evidenci&oacute; diferencia estad&iacute;sticamente significativa con el sistema Cerec In-lab<sup><sup>&reg;</sup></sup>.</p>       ]]></body>
<body><![CDATA[<p><b>Palabras clave:</b> zirconia-ytria Procera, zirconia ytria Cerec in-Lab, CAD/CAM, adaptaci&oacute;n marginal, ajuste interno.</p>  <hr noshade>           <p><b>ABSTRACT</b></p>           <p><b>INTRODUCTION:</b> the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera<sup>&reg;</sup> and Cerec In-lab<sup>&reg;</sup> CAD/CAM systems.    <br>  <b>METHODS:</b> fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera<sup><sup>&reg;</sup></sup> and Cerec In-lab YZ cubes<sup><sup>&reg;</sup></sup> (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment&sbquo;s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student&sbquo;s paired t test and Dunnett&sbquo;test.    <br>  <b>RESULTS:</b> marginal adaptation mean for the control group was 18.24&plusmn;4.81&micro;m and Procera<sup><sup>&reg;</sup></sup> 21.62 &micro;m &plusmn;12.15 &micro;m, while the average for Cerec In-lab<sup><sup>&reg;</sup></sup> was 47.34 &micro;m &plusmn;17.72 &micro;m. The internal fit for the control group was 34,60 &micro;m &plusmn;16.16 &micro;m and Procera<sup><sup>&reg;</sup></sup> group was of 118.67 &micro;m &plusmn;50.84 &micro;m in average and Cerec In-lab<sup><sup>&reg;</sup></sup> 65.62 &micro;m &plusmn;25.80 &micro;m.    <BR>  <b>CONCLUSION:</b> the metal alloy and zirconia ytrya frameworks fabricated with Procera<sup><sup>&reg;</sup></sup> and Cerec In-lab<sup><sup>&reg;</sup></sup> CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec<sup><sup>&reg;</sup></sup> frameworks are within the ranges reported in the literature. While the mean for the Procera<sup><sup>&reg;</sup></sup> group was 118.67 &micro;m &plusmn;50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab<sup><sup>&reg;</sup></sup> system.</p>      <p><b>Key words:</b> zirconia-ytria Procera, zirconia ytria Cerec in-Lab, CAD/CAM, marginal adaptation, internal adjustment.</p>  <hr noshade>     <p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      ]]></body>
<body><![CDATA[<p>En la actualidad, debido al incremento en los requerimientos est&eacute;ticos, se han desarrollado restauraciones libres de metal con excelentes propiedades &oacute;pticas y de biocompatibilidad.<sup>1-11</sup> Por esto en los &uacute;ltimos a&ntilde;os se han implementado numerosos sistemas cer&aacute;micos y de procesamiento para la obtenci&oacute;n de restauraciones completamente cer&aacute;micas con una gama amplia de aplicaciones. En particular, los materiales completamente cer&aacute;micos con base en &oacute;xido de zirconio ZrO<sub>2</sub> muestran notables propiedades est&eacute;ticas, combinadas con la alta biocompatibilidad y las excelentes propiedades mec&aacute;nicas.<sup>12</sup> El ZrO<sub>2</sub> es un material policristalino libre de matriz v&iacute;trea, com&uacute;nmente estabilizado con &oacute;xido de ytrio (3 mol%), obteniendo de este modo un material conocido como zirconia tetragonal parcialmente estabilizada con ytrio (Y-TZP).<sup>12, 13</sup> En comparaci&oacute;n con otras cer&aacute;micas, la Y-TZP presenta mejores propiedades mec&aacute;nicas y una resistencia superior a la fractura. El material tiene una resistencia flexural de 900-1.400 MPa, resistencia a la fractura por encima de 10 MPa/m0,5 y m&oacute;dulo de elasticidad de 210 GPa.<sup>14, 15</sup> Estudios cl&iacute;nicos reportan porcentajes de &eacute;xito entre 97,8 y 100% en restauraciones elaboradas con Y-TZP, con periodos de observaci&oacute;n entre dos y cinco a&ntilde;os.<sup>16, 17</sup></p>      <p>El uso de las cer&aacute;micas con ZrO<sub>2</sub> ha tra&iacute;do consigo la tecnolog&iacute;a CAD/CAM,<sup>18, 19</sup> que permite hacer restauraciones de excelente calidad, cuyo dise&ntilde;o y elaboraci&oacute;n son asistidos por computador. En los sistemas que utilizan la zirconia tetragonal policristalina como material cer&aacute;mico para la elaboraci&oacute;n de estructuras para puentes fijos o coronas individuales en los segmentos anteriores y posteriores est&aacute;n los que en su dise&ntilde;o y elaboraci&oacute;n son asistidos por computador; como el sistema Cerec in Lab<sup><sup>&reg;</sup></sup> y el Procera<sup><sup>&reg;</sup></sup> conocidos como sistemas CAD/CAM. Estos han mostrado grandes ventajas cl&iacute;nicas sobre los otros sistemas ya sean asistidos o no por computador.</p>      <p>Adem&aacute;s de las propiedades mec&aacute;nicas y &oacute;pticas, la adaptaci&oacute;n marginal y ajuste interno, son v&aacute;lidos como importantes criterios de calidad y &eacute;xito cl&iacute;nico de las restauraciones completamente cer&aacute;micas.<sup>20-22</sup> Una adaptaci&oacute;n marginal deficiente es potencialmente perjudicial tanto para el diente como para los tejidos de soporte<sup>23, 24</sup> porque genera microfiltraci&oacute;n, favorece la disoluci&oacute;n del cemento<sup>25</sup> e incrementa la retenci&oacute;n de placa,<sup>26, 27</sup> lo cual puede llevar a la aparici&oacute;n de caries secundaria con la subsecuente inflamaci&oacute;n pulpar.<sup>28, 29</sup> Adicionalmente, la desadaptaci&oacute;n marginal de una restauraci&oacute;n cambia la distribuci&oacute;n de la microflora, y puede inducir la aparici&oacute;n de enfermedad periodontal.<sup>17, 23, 28-33</sup> Sailer<sup>17</sup> reporto el porcentaje de 22% de caries secundaria luego de cinco a&ntilde;os de cementar restauraciones completamente cer&aacute;micas.</p>      <p>Aparte del aspecto biol&oacute;gico, el adecuado ajuste de la restauraci&oacute;n es importante para asegurar el desempe&ntilde;o confiable de la restauraci&oacute;n ante las cargas funcionales.<sup>34</sup></p>      <p>La adaptaci&oacute;n marginal de las restauraciones metalcer&aacute;micas ha sido ampliamente documentada y brinda un punto de referencia para las restauraciones completamente cer&aacute;micas.<sup>35-37</sup></p>      <p>Varios autores han estudiado la adaptaci&oacute;n marginal de las restauraciones completamente cer&aacute;micas.<sup>21, 29, 35, 38-50</sup></p>      <p>Diferentes valores han sido propuestos en la literatura como m&aacute;xima desadaptaci&oacute;n marginal aceptable cl&iacute;nicamente, dependiendo del tipo de restauraci&oacute;n y del estudio. Existe consenso de varios autores que la desadaptaci&oacute;n promedio por debajo de 120 &micro;m es cl&iacute;nicamente aceptable.<sup>21, 51-53</sup> Estudios in vitro han reportado el promedio cl&iacute;nicamente aceptable de desadaptaci&oacute;n marginal de <sup>64-83</sup> &micro;m en restauraciones individuales completamente cer&aacute;micas elaboradas en sistemas CAD/CAM;<sup>21, 29</sup> mientras que otros<sup>53, 54</sup> reportan discrepancias marginales aceptables entre 50 y 100 &micro;m. Reich<sup>32</sup> mostr&oacute; el promedio de desadaptaci&oacute;n marginal de 80 &micro;m en restauraciones con estructura en zirconia fabricadas mediante tecnolog&iacute;a CAD/CAM (Lava, 3M ESPE) y McLean y von Fraunhofer55 proponen que la restauraci&oacute;n puede ser exitosa con una brecha marginal y un espacio para el cemento entre 50 y 120 mm. Estos valores parecen ser favorables para el agente cementante para lograr la adhesi&oacute;n resistente.<sup>56, 57</sup></p>      <p>Los datos acerca del ajuste interno de restauraciones completamente cer&aacute;micas, son pocos. Reich<sup>32</sup> reporta valores promedio de ajuste interno de 154 &micro;m en restauraciones con estructuras en ZrO<sub>2</sub> elaboradas en el sistema Cerec, mientras que otros autores<sup>39</sup> reportan valores de 103 &micro;m para este mismo tipo de restauraciones.</p>      <p>Teniendo en cuenta la importancia de estos materiales para la odontolog&iacute;a restauradora, este proyecto de investigaci&oacute;n busc&oacute; evaluar la adaptaci&oacute;n marginal y el ajuste interno in vitro en estructuras de zirconia-ytria elaboradas con los sistemas CAD/ CAM Procera<sup><sup>&reg;</sup></sup> y Cerec in Lab<sup><sup>&reg;</sup></sup>. La hip&oacute;tesis considerada en el estudio es que no hay diferencias significativas en los valores de adaptaci&oacute;n marginal y ajuste interno entre las estructuras elaboradas con los sistemas evaluados en el presente estudio.</p>      <p>&nbsp;</p>      ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana"><b>M&Eacute;TODOS</b></font></p>      <p>Para este estudio se tomaron 15 pilares prefabricados contorneados elaborados en aleaci&oacute;n de titanio de la casa Zimmer Dental<sup><sup>&reg;</sup></sup> para implantes Taper Screw Vent<sup><sup>&reg;</sup></sup> de plataforma de 3,5 mm de di&aacute;metro (Hex- Lock Contour titanio rectos de 3 mm de altura del collar y de 4,5 mm de m&aacute;ximo contorno, con l&iacute;nea de terminaci&oacute;n de chafl&aacute;n profundo (<a href="#f1">figura 1</a>).</p>      <p align="center"><a name="f1"><img src=/img/revistas/rfoua/v22n2/v22n2a06f1.jpg></a> </p>      <p>Los pilares fueron marcados y distribuidos en un total de cinco espec&iacute;menes en cada grupo de evaluaci&oacute;n (<a href="#t1">tabla 1</a>).</p>      <p align="center"><a name="t1"><img src=/img/revistas/rfoua/v22n2/v22n2a06t1.jpg></a> </p>      <p>Cada esp&eacute;cimen se manipul&oacute; en un an&aacute;logo de implante para el proceso de fabricaci&oacute;n de las estructuras de la aleaci&oacute;n noble paladio-oro y durante el escaneado para la elaboraci&oacute;n de las estructuras CAD/CAM en zirconia-ytria y posteriormente para manipular los espec&iacute;menes durante las mediciones.</p>      <p>Se fabricaron cinco estructuras de zirconia-ytria en cada uno de los sistemas a evaluar (Procera<sup><sup>&reg;</sup></sup> y Cerec in Lab<sup><sup>&reg;</sup></sup>) y cinco en aleaci&oacute;n de paladio-oro para el grupo control (Spartan-Plus Ivoclar-Vivadent<sup><sup>&reg;</sup></sup>), para un total de quince estructuras.</p>      <p>Cada una de las estructuras fue fabricada por un t&eacute;cnico dental experimentado y entrenado espec&iacute;ficamente en estos sistemas. La elaboraci&oacute;n se hizo de acuerdo con las instrucciones de cada fabricante y los laboratoristas no ten&iacute;an conocimiento del prop&oacute;sito de la elaboraci&oacute;n de estas estructuras.</p>      <p>Para la fabricaci&oacute;n de cada una de las estructuras se usaron grosores en la capa de espaciador, as&iacute;: para las estructuras Procera 70 &micro;m (no modificable desde el software; este valor se obtuvo de las especificaciones t&eacute;cnicas de la casa fabricante sobre su sistema y software), para las Cerec 30 &micro;m y para las estructuras en aleaci&oacute;n noble se emple&oacute; laca espaciadora oro de 10 &micro;m (Bredent<sup><sup>&reg;</sup></sup>).</p>      <p>La adaptaci&oacute;n marginal se evalu&oacute; tomando ocho mediciones en diferentes puntos a lo largo del margen cada 45&deg; de la circunferencia de la l&iacute;nea de terminaci&oacute;n y se tom&oacute; como medida de la adaptaci&oacute;n marginal la distancia entre el borde de la estructura y el margen de la preparaci&oacute;n del pilar en titanio (<a href="#f2">figura 2</a>).</p>      ]]></body>
<body><![CDATA[<p align="center"><a name="f2"><img src=/img/revistas/rfoua/v22n2/v22n2a06f2.jpg></a> </p>      <p>Para la medici&oacute;n de la adaptaci&oacute;n marginal de cada una de las estructuras, al igual que para la medici&oacute;n del ajuste interno, se utiliz&oacute; un microscopio &oacute;ptico Nikon Epiphot 200<sup><sup>&reg;</sup></sup> con c&aacute;mara ccd a un aumento de 50X.</p>      <p>Las medidas de cada esp&eacute;cimen se fotografiaron y se evaluaron en un software analizador de im&aacute;genes (Nis Elements de Nikon<sup><sup>&reg;</sup></sup>) con una escala de medici&oacute;n de 200 &micro;m.</p>      <p>El ajuste interno se determin&oacute; por medio de ocho mediciones de cada muestra sobre cortes transversales, desde la superficie externa del pilar de titanio a la superficie interna de la estructura.</p>      <p>Para tales mediciones se hizo previamente la cementaci&oacute;n definitiva de cada estructura sobre su respectivo pilar, con ion&oacute;mero de vidrio Ketac Cem Easymix 3M Espe<sup><sup>&reg;</sup></sup>. El material de cementaci&oacute;n se manipul&oacute; de acuerdo con las instrucciones del fabricante aplicando una fuerza uniforme de 200 g medida por medio de un dinam&oacute;metro digital.</p>      <p>Una vez retirados los excesos de cemento, cada esp&eacute;cimen fue completamente cubierto en un cubo de resina acr&iacute;lica de 25 x 25 mm con el objetivo de proteger los espec&iacute;menes durante el corte y evitar su deterioro (<a href="#f3">figura 3</a>).</p>      <p align="center"><a name="f3"><img src=/img/revistas/rfoua/v22n2/v22n2a06f3.jpg></a> </p>      <p>Cada muestra se seccion&oacute; en sentido vest&iacute;bulo lingual por medio de una cortadora el&eacute;ctrica por disco abrasivo Sampl Met 2 (Buehler) usando refrigeraci&oacute;n continua; seleccionando la mitad de mayor homogeneidad para su lectura en el microscopio (<a href="#f4">figura 4</a>).</p>      <p align="center"><a name="f4"><img src=/img/revistas/rfoua/v22n2/v22n2a06f4.jpg></a> </p>      <p>Se tomaron entonces cuatro mediciones vestibulares y cuatro linguales, desde la superficie externa del pilar de titanio a la superficie interna de la estructura (<a href="#f5">figura 5</a>).</p>      ]]></body>
<body><![CDATA[<p align="center"><a name="f5"><img src=/img/revistas/rfoua/v22n2/v22n2a06f5.jpg></a> </p>      <p>Las mediciones de los cortes se hicieron por medio del microscopio &oacute;ptico descrito anteriormente y fueron expresadas en micr&oacute;metros.</p>      <p>Todas las mediciones fueron tomadas en el Laboratorio de materialograf&iacute;a y pol&iacute;meros de Ingenier&iacute;a de Materiales de la Universidad de Antioquia, por un t&eacute;cnico entrenado y calibrado previamente, con la asesor&iacute;a del ingeniero metal&uacute;rgico Alejandro Echavarr&iacute;a.</p>      <p>Se dise&ntilde;aron tablas en Excel para registrar las diferentes mediciones en cada sistema. Para el procesamiento de los datos y para el an&aacute;lisis de la informaci&oacute;n se utiliz&oacute; el SPSS versi&oacute;n 17.0.</p>      <p>Para el an&aacute;lisis estad&iacute;stico, inicialmente se hizo un an&aacute;lisis descriptivo que inclu&iacute;a medidas de tendencia central y de dispersi&oacute;n, posteriormente se evalu&oacute; si las variables, adaptaci&oacute;n marginal y ajuste interno, cumpl&iacute;an los supuestos de normalidad (Prueba de Shapiro-Wilks) y homocesticidad (Prueba de Levine) y por &uacute;ltimo se hizo un an&aacute;lisis de varianza de una v&iacute;a y como prueba de significancia estad&iacute;stica se utiliz&oacute; la t de Student para diferencia de medias y la prueba de Dunnett, en esta &uacute;ltima, tomando como grupo control las estructuras de aleaci&oacute;n met&aacute;lica noble paladio-oro. En ambos casos la hip&oacute;tesis nula considerada fue la igualdad de medias para los diferentes procedimientos. Se tom&oacute; un nivel de significancia de 5% (8 = 0,05).</p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>RESULTADOS</b></font></p>      <p><b>Adaptacion marginal</b></p>      <p>El valor promedio de adaptaci&oacute;n marginal para el grupo de aleaci&oacute;n met&aacute;lica fue 18,24 &plusmn; 4,81 &micro;m (<a href="#t2">tabla 2</a>) el cual no tuvo diferencias estad&iacute;sticamente significativas (p &lt; 0,05) con el promedio de adaptaci&oacute;n marginal encontrado para el grupo Procera 21,62 &plusmn; 12,15 &micro;m (tabla 2). Por el contrario el grupo Cerec in Lab mostr&oacute; el promedio de adaptaci&oacute;n marginal de 47,34 &plusmn; 17,72 &micro;m (<a href="#t2">tabla 2</a>). Se muestra diferencia estad&iacute;sticamente significativa cuando se compara este promedio con los obtenidos para el grupo Procera y aleaci&oacute;n met&aacute;lica (avalado por t-Test y Dunnett).</p>      <p align="center"><a name="t2"><img src=/img/revistas/rfoua/v22n2/v22n2a06t2.jpg></a> </p>      ]]></body>
<body><![CDATA[<p>A pesar de las diferencias estad&iacute;sticamente significativas encontradas para el grupo Cerec, con respecto al grupo control y Procera, los valores promedio encontrados en todos los grupos est&aacute;n por debajo de los l&iacute;mites reportados en la literatura como cl&iacute;nicamente aceptables de adaptaci&oacute;n marginal.</p>      <p>Las <a href="#t3">tablas 3</a>, <a href="#t4">4</a> y <a href="#t5">5</a> muestran las ocho mediciones de adaptaci&oacute;n marginal, hechas en cada una de las cinco muestras de cada grupo de observaci&oacute;n.</p>      <p align="center"><a name="t3"><img src=/img/revistas/rfoua/v22n2/v22n2a06t3.jpg></a> </p>      <p align="center"><a name="t4"><img src=/img/revistas/rfoua/v22n2/v22n2a06t4.jpg></a> </p>      <p align="center"><a name="t5"><img src=/img/revistas/rfoua/v22n2/v22n2a06t5.jpg></a> </p>      <p>Las <a href="#f6">figuras 6</a>, <a href="#f7">7</a> y <a href="#f8">8</a> muestran fotograf&iacute;as de las mediciones de adaptaci&oacute;n marginal en cada grupo.</p>      <p align="center"><a name="f6"><img src=/img/revistas/rfoua/v22n2/v22n2a06f6.jpg></a> </p>      <p align="center"><a name="f7"><img src=/img/revistas/rfoua/v22n2/v22n2a06f7.jpg></a> </p>      <p align="center"><a name="f8"><img src=/img/revistas/rfoua/v22n2/v22n2a06f8.jpg></a> </p>      <p><b>Ajuste interno</b></p>      ]]></body>
<body><![CDATA[<p>El valor promedio de ajuste interno para el grupo de aleaci&oacute;n met&aacute;lica fue 34,60 &plusmn; 16,16 (<a href="#t6">tabla 6</a>); el cual fue estad&iacute;sticamente diferente (p &gt; 0,05) del promedio encontrado en el grupo Procera 118,67 &plusmn; 50,84 &micro;m (<a href="#t6">tabla 6</a>), mientras que para el grupo Cerec in-Lab el promedio de ajuste interno fue 65,62 &plusmn; 25,80 &micro;m, lo cual muestra que entre el promedio de este &uacute;ltimo grupo y el grupo control no hay diferencias estad&iacute;sticamente significativas, como tampoco las hay entre el grupo Procera y Cerec (avalado por t-Test y Dunnett).</p>      <p align="center"><a name="t6"><img src=/img/revistas/rfoua/v22n2/v22n2a06t6.jpg></a> </p>      <p>Las <a href="#t7">tablas 7</a>, <a href="#t8">8</a> y <a href="#t9">9</a> muestran las ocho mediciones de ajuste interno hechas en cada una de las cinco muestras de cada grupo de observaci&oacute;n.</p>      <p align="center"><a name="t7"><img src=/img/revistas/rfoua/v22n2/v22n2a06t7.jpg></a> </p>      <p align="center"><a name="t8"><img src=/img/revistas/rfoua/v22n2/v22n2a06t8.jpg></a> </p>      <p align="center"><a name="t9"><img src=/img/revistas/rfoua/v22n2/v22n2a06t9.jpg></a> </p>      <p>Las figuras <a href="#f9">figuras 9</a>, <a href="#f10">10</a> y <a href="#f11">11</a>  muestran fotograf&iacute;as de las mediciones de ajuste interno en cada grupo.</p>      <p align="center"><a name="f9"><img src=/img/revistas/rfoua/v22n2/v22n2a06f9.jpg></a> </p>      <p align="center"><a name="f10"><img src=/img/revistas/rfoua/v22n2/v22n2a06f10.jpg></a> </p>      <p align="center"><a name="f11"><img src=/img/revistas/rfoua/v22n2/v22n2a06f11.jpg></a> </p>       ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      <p>La adaptaci&oacute;n marginal de una restauraci&oacute;n prot&eacute;sica es de suma importancia para lograr un buen desempe&ntilde;o cl&iacute;nico a largo plazo. El promedio de adaptaci&oacute;n marginal obtenido en los sistemas CAD/CAM estudiados por medio de microscopio &oacute;ptico a 50X fue de 21,6 &plusmn; 12,1 &micro;m para el grupo Procera, de 47,3 &plusmn; 17,7 &micro;m para el sistema Cerec in Lab y de 18,2 &plusmn; 4,8 &micro;m para el grupo control.</p>      <p>El sistema Procera se comport&oacute; estad&iacute;sticamente mejor en t&eacute;rminos de adaptaci&oacute;n marginal que el sistema Cerec in Lab, de modo que la hip&oacute;tesis en la que se bas&oacute; el estudio fue negada. Posiblemente la raz&oacute;n por la que el sistema Procera present&oacute; un valor bajo de adaptaci&oacute;n marginal frente al sistema Cerec es por el mayor espacio para el cemento o ajuste interno que en este sistema, con un valor promedio de 118,6 &plusmn; 50,8 &micro;m frente a 65,6 &plusmn; 25,8 &micro;m del Cerec in Lab. Una brecha mayor de ajuste interno permite mayor asentamiento de las estructuras en zirconia-ytria, propiciando mejor adaptaci&oacute;n marginal. Algunos sistemas CAD/CAM promueven este tipo de estrategia de dise&ntilde;o y maquinado denominado "ajuste por mayor radio de corte" sin perjudicar las propiedades mec&aacute;nicas de la restauraci&oacute;n ni el comportamiento de la contracci&oacute;n de polimerizaci&oacute;n del cemento.</p>      <p>Los valores de adaptaci&oacute;n marginal reportados en nuestra investigaci&oacute;n coinciden con los reportados por Bindl y M&ouml;rmann en el 200529 en los que por medio de restauraciones in vitro evaluadas en microscopio, reportan valores de adaptaci&oacute;n marginal para el sistema Procera de 17 &plusmn; 16 &micro;m y de 43 &plusmn; 23 &micro;m para el Cerec in Lab<sup><sup>&reg;</sup></sup>. En esta investigaci&oacute;n tambi&eacute;n se presentaron valores altos de ajuste interno en el espacio del cemento de 136 &plusmn; 68 &micro;m para el grupo Procera y para el Cerec in Lab de 114 &plusmn; 58 &micro;m, siendo este valor significativamente mayor que el obtenido en nuestro estudio para este sistema.</p>      <p>Gonzalo y colaboradores en 2008 y 2009<sup>58, 59</sup> obtuvieron valores semejantes de adaptaci&oacute;n marginal, cuando se evaluaron sistemas similares a los de nuestro estudio, presentando el sistema Procera una adaptaci&oacute;n marginal de 26 &plusmn; 19 &micro;m y el Cerec in Lab de 40 &plusmn; 19 &micro;m.</p>      <p>Estos resultados confirman que los valores de adaptaci&oacute;n marginal en las restauraciones individuales en zirconia estabilizadas con ytria elaboradas con los sistemas CAD/CAM Procera y Cerec in Lab, aunque presenten diferencias estad&iacute;sticamente significativas al compararse con las restauraciones elaboradas en aleaciones nobles Pd-Au y entre ellas, se encuentran en los valores aceptados cl&iacute;nicamente por la literatura cient&iacute;fica de 100 a 120 &micro;m. Este grado de adaptaci&oacute;n marginal les permite a estas restauraciones tener alta expectativa de supervivencia y &eacute;xito cl&iacute;nico a largo plazo.</p>      <p>El ajuste interno o espacio para el cemento en las restauraciones libres de metal elaboradas con &oacute;xido de zirconio estabilizado con &oacute;xido de ytria, debe ser un espacio uniforme para facilitar el asentamiento de la estructura sin comprometer la retenci&oacute;n y la resistencia de la misma. Este aspecto en las restauraciones completamente cer&aacute;micas es de suma importancia debido a que este tipo de material es m&aacute;s fr&aacute;gil que las estructuras hechas en aleaciones met&aacute;licas, ya sean predominantemente v&iacute;treas o altamente cristalinas. La debilidad de la cer&aacute;mica se debe a su sensibilidad ante los esfuerzos tensiles y a la posterior propagaci&oacute;n de grietas en el material. Tuntiprawon y Wilson<sup>49</sup> demostraron que el ajuste interno puede afectar el pron&oacute;stico a largo plazo en las coronas elaboradas en cer&aacute;mica v&iacute;trea sobre matriz de platino (Vitadur-N). Los autores evidenciaron que las restauraciones libres de metal v&iacute;treas mostraban mayor resistencia compresiva a la fractura cuando el promedio de ajuste interno en las paredes axiales de la preparaci&oacute;n era de una dimensi&oacute;n de 73 &micro;m. Tambi&eacute;n se demostr&oacute; que si el promedio de ajuste interno se aumentaba a 122 &micro;m se disminu&iacute;a la resistencia del material sin lograr mejor asentamiento o adaptaci&oacute;n marginal de la estructura.</p>      <p>El efecto del grosor del cemento sobre la resistencia de las restauraciones libres de metal elaboradas con estructuras en zirconia-ytria podr&iacute;a ser diferente al de las cer&aacute;micas v&iacute;treas evaluadas por Tuntiprawon. Rosentritt y colaboradores en 2009<sup>60</sup></p> quienes evidenciaron que la variable de mayor influencia en la resistencia de las restauraciones molares en zirconia-ytria era el grosor y el dise&ntilde;o de la estructura de soporte a la cer&aacute;mica de blindaje. El efecto que present&oacute; el espesor del cemento fue poco significativo en la resistencia al envejecimiento termomec&aacute;nico del material. La mayor limitante del estudio fue el espesor utilizado en cada grupo de evaluaci&oacute;n, que era de 30 y 40 &micro;m en los de mayor amplitud de ajuste interno. La amplitud del espacio para el cemento presentada por el sistema Cerec in Lab de 65,62 &plusmn; 25,8 &micro;m aproxima a este rango de ajuste interno, siendo el caso contrario con el sistema Procera All Zirkon con un valor de ajuste interno de 118,67 &plusmn; 50,8 &micro;m. Aumentar el espacio para el cemento en estos valores podr&iacute;an limitar el grosor de la cer&aacute;mica en estas restauraciones, disminuyendo potencialmente la resistencia del material. Debido a esto se sugiere hacer estudios in vivo que puedan demostrar el efecto que tiene el aumento del espacio del cemento en rangos aproximados a las 120 &micro;m sobre la resistencia de restauraciones libres de metal elaboradas con zirconia-ytria.</p>      <p>La principal limitante del presente estudio en la metodolog&iacute;a para determinar el ajuste interno en las estructuras de los sistemas investigados fue usar la t&eacute;cnica de "corte seccional" de las estructuras cementadas. La t&eacute;cnica empleada solo permite la medici&oacute;n en ocho puntos preseleccionados en las paredes axiales de los pilares utilizados, lo cual puede no reflejar de manera exacta el ajuste interno de las estructuras. Otra limitante de importancia fueron las condiciones ideales en las que se llev&oacute; a cabo el estudio, lo cual impide la transferencia directa de sus conclusiones a la pr&aacute;ctica cl&iacute;nica diaria.</p>      ]]></body>
<body><![CDATA[<p>Como recomendaci&oacute;n para futuras investigaciones en la l&iacute;nea de cer&aacute;mica se sugiere determinar la adaptaci&oacute;n marginal y el ajuste interno de restauraciones de puentes fijos de tramos amplios en zirconia-ytria, por medio de mediciones tridimensionales del espacio para el cemento que reflejen de manera exacta el ajuste interno de este tipo de restauraciones prot&eacute;sicas.</p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>CONCLUSIONES</b></font></p>      <p>Teniendo en cuenta las limitantes presentadas en este estudio podemos concluir que:      <p>Los valores de adaptaci&oacute;n marginal obtenidos para las estructuras de aleaci&oacute;n met&aacute;lica noble Pd-Au 18,24 &plusmn; 4,81 &micro;m y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera 21,62 &plusmn; 12,15 &micro;m y Cerec in Lab 47,34 &plusmn; 17,72 &micro;m, est&aacute;n en los valores cl&iacute;nicamente aceptables reportados en la literatura de 100 a 120 &micro;m.</p>      <p>Los valores de ajuste interno obtenidos para los grupos de aleaci&oacute;n met&aacute;lica 34,60 &plusmn; 16,16 &micro;m y Cerec in Lab<sup><sup>&reg;</sup></sup> 65,62 &plusmn; 25,80 &micro;m, se encuentran en el rango descrito en la literatura; mientras que el promedio obtenido para el grupo Procera<sup><sup>&reg;</sup></sup> 118,67 &plusmn; 50,84 &micro;m, aunque se acerc&oacute; al l&iacute;mite m&aacute;ximo de ajuste interno reportado en la literatura no se evidenci&oacute; diferencia estad&iacute;sticamente significativa con el sistema Cerec in Lab<sup><sup>&reg;</sup></sup>.</p>      <p>Las estructuras met&aacute;licas mostraron mejores promedios de adaptaci&oacute;n marginal y ajuste interno con respecto a las estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera<sup><sup>&reg;</sup></sup> y Cerec in Lab<sup><sup>&reg;</sup></sup>, lo cual evidencia las razones por las que siguen siendo consideradas "la regla de oro" de las restauraciones prot&eacute;sicas fijas.</p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>REFERENCIAS</b></font></p>      <!-- ref --><p>1. Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA. Alumina ceramic implant abutments used for single-tooth replacement: A prospective 1-to 3-year multicenter study. Int J Prost 2001; 14: 432-438.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0121-246X201100010000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: An overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008; 204:505-511.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201100010000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Bindl A, Mormann WH. Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years. Eur J Oral Sci 2004; 112: 197-204.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X201100010000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Devaud V. Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent 2005; 17: 508-510.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X201100010000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Federlin M, Wagner J, Manner T, Hiller KA, Schmalz G. Three-year clinical performance of cast gold vs. ceramic partial crowns. Clin Oral Investig 2007; 11: 345-352.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0121-246X201100010000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Raigrodski AJ, Chiche GJ. All-ceramic fixed partial dentures, part I: in vitro studies. J Esthet Restor Dent 2002; 14: 188-119.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X201100010000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Raigrodski AJ, Chiche GJ, Swift EJ Jr. All-ceramic fixed partial dentures, part III: Clinical studies. J Esthet Restor Dent 2002; 14: 313-319.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0121-246X201100010000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007; 20: 383-388.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X201100010000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Sorensen JA, Choi C, Fanuscu MI, Mito WT. IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc 1998; 26:130-136.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0121-246X201100010000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005; 32: 180-187.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0121-246X201100010000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Weaver JD, Johnson GH, Bales DJ. Marginal adaptation of castable ceramic crowns. J Prosthet Dent 1991; 66: 747-753.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0121-246X201100010000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Kelly JR, Denry I. Stabilized zirconia as a structural ceramic: an overview. Dent Mater 2008; 24: 289-298.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0121-246X201100010000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Suttor D, Bunke K, Hoescheler S, Hauptmann H, Hertlein G. Lava-the system for all-ceramic ZrO2 crown and bridge frameworks. Int J Comput Dent 2001; 3: 195-206.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0121-246X201100010000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Christel P, Meunier A, Heller M, Torre JP, Peille CN. Mechanical properties and shortterm in-vivo evaluation of yttrium-oxidepartially-stabilized zirconia. J Biomed Mater Res 1989; 23: 45-61.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000125&pid=S0121-246X201100010000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of allceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004; 20: 449-456.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0121-246X201100010000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Vult von Steyern P. All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems. Swed Dent J 2005; 173 supl: 1-69.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0121-246X201100010000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Sailer I, Feh&eacute;r A, Filser F, Gauckler LJ, L&uuml;thy H, H&auml;mmerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007; 20: 383-388.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0121-246X201100010000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Filser F, Kocher P, Weibel F, L&uuml;thy H, Sch&auml;rer P, Gauckler LJ. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining. Int J Comput Dent 2001; 2: 89-103.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0121-246X201100010000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. Mehl A, Hickel R. Current state of development and perspectives of machine-based production methods for dental restorations. Int J Comp Dent 1999; 2: 9-35.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0121-246X201100010000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Pera P, Gilodi S, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crowns. J Prosthet Dent 1994; 72: 585-590.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0121-246X201100010000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns. Int J Prosthodont 1997; 10: 478-484.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0121-246X201100010000600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent 1990; 64: 18-24.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000133&pid=S0121-246X201100010000600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23. Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991; 65: 357-364.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0121-246X201100010000600023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24. Knoernschild KL, Campbell SD. Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 2000; 84: 492-498.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000135&pid=S0121-246X201100010000600024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25. Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991; 65: 436-442.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0121-246X201100010000600025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Valderhaug J, Birkeland JM. Periodontal conditions in patients 5 years following insertion of fixed protheses. J Oral Rehabil 1976; 3: 237-243.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000137&pid=S0121-246X201100010000600026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>27. Valderhaug J, Heloe LA. Oral hygiene in a group of supervised patients with fixed protheses. J Periodontol 1977; 48: 221-224.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0121-246X201100010000600027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>28. Goldman M, Laosonthorn P, White RR. Microleakage-full crowns and the dental pulp. J Endod 1992; 18: 473-475.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S0121-246X201100010000600028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>29. Bindl A, M&ouml;rmann WH. Marginal and internal fit of all ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 2005; 32: 441-447.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0121-246X201100010000600029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30. Lang NP, Kiel RA, Anderhalden K. Clinical and microbiological effects of subgingival restorations with overhanging or clinical perfect margins. J Clin Periodontol 1983; 10: 563-578.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000141&pid=S0121-246X201100010000600030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>31. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62: 405-408.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0121-246X201100010000600031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>32. Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005; 113: 174-179.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000143&pid=S0121-246X201100010000600032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>33. Schaerer P, Sato T, Wohlwend A. A comparison of the marginal fit of three cast ceramic crown systems. J Prosthet Dent 1988; 59: 534-542.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0121-246X201100010000600033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>34. Rekow D, Thompson VP. Near-surface damage a persistent problem in crowns obtained by computer-aided design and manufacturing. Proc Inst Mech Eng H 2005; 219(4): 233-243.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000145&pid=S0121-246X201100010000600034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>35. Beschnidt SM, Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. J Oral Rehabil 1999; 26: 582-593.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0121-246X201100010000600035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>36. Hamaguchi H, Cacciatore A, Tueller VM. Marginal distortion of the porcelain-bonded-to-metal complete crown: An SEM study. J Prosthet Dent 1982; 47: 146-153.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000147&pid=S0121-246X201100010000600036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>37. Anusavice KJ, Carroll JE. Effect of incompatibility stress on the fit of metal-ceramic crowns. J Dent Res 1987; 66: 1341-1344.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0121-246X201100010000600037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>38. Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001; 26: 367-374.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000149&pid=S0121-246X201100010000600038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>39. Bindl A, M&ouml;rmann WH. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent 2007; 27: 567-575.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0121-246X201100010000600039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>40. Reich S, Kappe K, Teschner H, Schmitt J. Clinical fit of four unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 2008; 116: 579-584.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000151&pid=S0121-246X201100010000600040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>41. Coli P, Karlsson S. Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont 2004; 17: 577-580.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0121-246X201100010000600041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>42. May KB, Russel MM, Razzoog ME, Lang BR. Precision of fit: the Procera AllCeram crown. J Prosthet Dent 1998; 80: 394-404.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000153&pid=S0121-246X201100010000600042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>43. Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009; 25(1): 94-102.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000154&pid=S0121-246X201100010000600043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>44. Fleming GJ, Dobinson MM, Landini G, Harris JJ. An in vitro investigation of the accuracy of fit of Procera and empress crowns. Eur J Prosthodont Restor Dent 2005; 13: 109-114.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000155&pid=S0121-246X201100010000600044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>45. Grey NJ, Piddock V, Wilson MA. In vitro comparison of conventional crowns and a new all-ceramic system. J Dent 1993; 21: 47-51.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000156&pid=S0121-246X201100010000600045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>46. Hung SH, Hung KS, Eick JD, Chappell RP. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent 1990; 63: 26-31.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000157&pid=S0121-246X201100010000600046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>47. Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S. Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 2005; 32: 526-530.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000158&pid=S0121-246X201100010000600047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>     <p>&nbsp;</p>      <p><b>RECIBIDO: NOVIEMBRE 30/2010 - ACEPTADO: MARZO 15/2011</b></p>      <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>CORRESPONDENCIA</b></font></p>      <p>Carlos Bernardo Caparroso P&eacute;rez    <br> Facultad de Odontolog&iacute;a    <br> Universidad de Antioquia    <br> Correo electr&oacute;nico: <a href="mailto:ccaparroso@gmail.com">ccaparroso@gmail.com</a></p>      <p>Caparroso CB, Mar&iacute;n DV, Echavarr&iacute;a A. Adaptaci&oacute;n marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera<sup>&reg;</sup> y Cerec in-Lab<sup>&reg;</sup>. Rev Fac Odontol Univ Antioq 2011; 22(2): 186-197.</p>       <p>Caparroso CB, Mar&iacute;n DV, Echavarr&iacute;a A. Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera<sup>&reg;</sup> and Cerec in-Lab<sup>&reg;</sup> CAD/CAM systems. Rev Fac Odontol Univ Antioq 2011; 22(2): 186-197.</p>   </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Andersson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[BR]]></given-names>
</name>
<name>
<surname><![CDATA[Scheller]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Scharer]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alumina ceramic implant abutments used for single-tooth replacement: A prospective 1-to 3-year multicenter study]]></article-title>
<source><![CDATA[Int J Prost]]></source>
<year>2001</year>
<volume>14</volume>
<page-range>432-438</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beuer]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Schweiger]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Digital dentistry: An overview of recent developments for CAD/CAM generated restorations]]></article-title>
<source><![CDATA[Br Dent J]]></source>
<year>2008</year>
<volume>204</volume>
<page-range>505-511</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bindl]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mormann]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years]]></article-title>
<source><![CDATA[Eur J Oral Sci]]></source>
<year>2004</year>
<volume>112</volume>
<page-range>197-204</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devaud]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Guidelines for success with zirconia ceramics: the changing standards]]></article-title>
<source><![CDATA[Pract Proced Aesthet Dent]]></source>
<year>2005</year>
<volume>17</volume>
<page-range>508-510</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Federlin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Manner]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hiller]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Schmalz]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[ceramic partial crowns]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2007</year>
<volume>11</volume>
<page-range>345-352</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raigrodski]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Chiche]]></surname>
<given-names><![CDATA[GJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[All-ceramic fixed partial dentures, part I: in vitro studies]]></article-title>
<source><![CDATA[J Esthet Restor Dent]]></source>
<year>2002</year>
<volume>14</volume>
<page-range>188-119</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raigrodski]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Chiche]]></surname>
<given-names><![CDATA[GJ]]></given-names>
</name>
<name>
<surname><![CDATA[Swift]]></surname>
<given-names><![CDATA[EJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[All-ceramic fixed partial dentures, part III: Clinical studies]]></article-title>
<source><![CDATA[J Esthet Restor Dent]]></source>
<year>2002</year>
<volume>14</volume>
<page-range>313-319</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sailer]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Feher]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Filser]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gauckler]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[Luthy]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hammerle]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Five-year clinical results of zirconia frameworks for posterior fixed partial dentures]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>383-388</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Fanuscu]]></surname>
<given-names><![CDATA[MI]]></given-names>
</name>
<name>
<surname><![CDATA[Mito]]></surname>
<given-names><![CDATA[WT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[IPS Empress crown system: three-year clinical trial results]]></article-title>
<source><![CDATA[J Calif Dent Assoc]]></source>
<year>1998</year>
<volume>26</volume>
<page-range>130-136</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vult]]></surname>
<given-names><![CDATA[von Steyern P]]></given-names>
</name>
<name>
<surname><![CDATA[Carlson]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Nilner]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A 2-year clinical study]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>180-187</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weaver]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
<name>
<surname><![CDATA[Bales]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal adaptation of castable ceramic crowns]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1991</year>
<volume>66</volume>
<page-range>747-753</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kelly]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Denry]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stabilized zirconia as a structural ceramic: an overview]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2008</year>
<volume>24</volume>
<page-range>289-298</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suttor]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bunke]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hoescheler]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hauptmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hertlein]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lava-the system for all-ceramic ZrO2 crown and bridge frameworks]]></article-title>
<source><![CDATA[Int J Comput Dent]]></source>
<year>2001</year>
<volume>3</volume>
<page-range>195-206</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Christel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Meunier]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Heller]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Torre]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Peille]]></surname>
<given-names><![CDATA[CN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical properties and shortterm in-vivo evaluation of yttrium-oxidepartially-stabilized zirconia]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1989</year>
<volume>23</volume>
<page-range>45-61</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guazzato]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Albakry]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ringer]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Swain]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Strength, fracture toughness and microstructure of a selection of allceramic materials Part II Zirconia-based dental ceramics]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2004</year>
<volume>20</volume>
<page-range>449-456</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vult]]></surname>
<given-names><![CDATA[von]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[All-ceramic fixed partial dentures]]></article-title>
<source><![CDATA[Studies on aluminum oxide- and zirconium dioxide-based ceramic systems. Swed Dent J]]></source>
<year>2005</year>
<volume>173</volume>
<page-range>1-69</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sailer]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Fehér]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Filser]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gauckler]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[Lüthy]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hämmerle]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Five-year clinical results of zirconia frameworks for posterior fixed partial dentures]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>383-388</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Filser]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kocher]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Weibel]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Lüthy]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Schärer]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Gauckler]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining]]></article-title>
<source><![CDATA[Int J Comput Dent]]></source>
<year>2001</year>
<volume>2</volume>
<page-range>89-103</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mehl]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hickel]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Current state of development and perspectives of machine-based production methods for dental restorations]]></article-title>
<source><![CDATA[Int J Comp Dent]]></source>
<year>1999</year>
<volume>2</volume>
<page-range>9-35</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pera]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Gilodi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bassi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Carossa]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro marginal adaptation of alumina porcelain ceramic crowns]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1994</year>
<volume>72</volume>
<page-range>585-590</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sulaiman]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Chai]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jameson]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Wozniak]]></surname>
<given-names><![CDATA[WT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>1997</year>
<volume>10</volume>
<page-range>478-484</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A standardized method for determination of crown margin fidelity]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1990</year>
<volume>64</volume>
<page-range>18-24</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Felton]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Kanoy]]></surname>
<given-names><![CDATA[BE]]></given-names>
</name>
<name>
<surname><![CDATA[Bayne]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Wirthman]]></surname>
<given-names><![CDATA[GP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of in vivo crown margin discrepancies on periodontal health]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1991</year>
<volume>65</volume>
<page-range>357-364</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Knoernschild]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2000</year>
<volume>84</volume>
<page-range>492-498</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Windeler]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An investigation of dental luting cement solubility as a function of the marginal gap]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1991</year>
<volume>65</volume>
<page-range>436-442</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valderhaug]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Birkeland]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Periodontal conditions in patients 5 years following insertion of fixed protheses]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>1976</year>
<volume>3</volume>
<page-range>237-243</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valderhaug]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Heloe]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oral hygiene in a group of supervised patients with fixed protheses]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>1977</year>
<volume>48</volume>
<page-range>221-224</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Laosonthorn]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microleakage-full crowns and the dental pulp]]></article-title>
<source><![CDATA[J Endod]]></source>
<year>1992</year>
<volume>18</volume>
<page-range>473-475</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bindl]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mörmann]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal and internal fit of all ceramic CAD/CAM crown-copings on chamfer preparations]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>441-447</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[NP]]></given-names>
</name>
<name>
<surname><![CDATA[Kiel]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Anderhalden]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical and microbiological effects of subgingival restorations with overhanging or clinical perfect margins]]></article-title>
<source><![CDATA[J Clin Periodontol]]></source>
<year>1983</year>
<volume>10</volume>
<page-range>563-578</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Bayne]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Holland]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Sulik]]></surname>
<given-names><![CDATA[WD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Considerations in measurement of marginal fit]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1989</year>
<volume>62</volume>
<page-range>405-408</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wichmann]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Nkenke]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Proeschel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems]]></article-title>
<source><![CDATA[Eur J Oral Sci]]></source>
<year>2005</year>
<volume>113</volume>
<page-range>174-179</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schaerer]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Sato]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Wohlwend]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the marginal fit of three cast ceramic crown systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1988</year>
<volume>59</volume>
<page-range>534-542</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rekow]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Thompson]]></surname>
<given-names><![CDATA[VP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Near-surface damage a persistent problem in crowns obtained by computer-aided design and manufacturing]]></article-title>
<source><![CDATA[Proc Inst Mech Eng H]]></source>
<year>2005</year>
<volume>219</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>233-243</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beschnidt]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Strub]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>1999</year>
<volume>26</volume>
<page-range>582-593</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamaguchi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Cacciatore]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Tueller]]></surname>
<given-names><![CDATA[VM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal distortion of the porcelain-bonded-to-metal complete crown: An SEM study]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1982</year>
<volume>47</volume>
<page-range>146-153</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anusavice]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Carroll]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of incompatibility stress on the fit of metal-ceramic crowns]]></article-title>
<source><![CDATA[J Dent Res]]></source>
<year>1987</year>
<volume>66</volume>
<page-range>1341-1344</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tinschert]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Natt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Mautsch]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Spiekermann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Anusavice]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2001</year>
<volume>26</volume>
<page-range>367-374</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bindl]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mörmann]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fit of all-ceramic posterior fixed partial denture frameworks in vitro]]></article-title>
<source><![CDATA[Int J Periodontics Restorative Dent]]></source>
<year>2007</year>
<volume>27</volume>
<page-range>567-575</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kappe]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Teschner]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Schmitt]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical fit of four unit zirconia posterior fixed dental prostheses]]></article-title>
<source><![CDATA[Eur J Oral Sci]]></source>
<year>2008</year>
<volume>116</volume>
<page-range>579-584</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coli]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Karlsson]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Precision of a CAD/CAM technique for the production of zirconium dioxide copings]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2004</year>
<volume>17</volume>
<page-range>577-580</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[May]]></surname>
<given-names><![CDATA[KB]]></given-names>
</name>
<name>
<surname><![CDATA[Russel]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Razzoog]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[BR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Precision of fit: the Procera AllCeram crown]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1998</year>
<volume>80</volume>
<page-range>394-404</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beuer]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Aggstaller]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gernet]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal and internal fits of fixed dental prostheses zirconia retainers]]></article-title>
<source><![CDATA[Dent Mater]]></source>
<year>2009</year>
<volume>25</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>94-102</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fleming]]></surname>
<given-names><![CDATA[GJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dobinson]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Landini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro investigation of the accuracy of fit of Procera and empress crowns]]></article-title>
<source><![CDATA[Eur J Prosthodont Restor Dent]]></source>
<year>2005</year>
<volume>13</volume>
<page-range>109-114</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grey]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Piddock]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro comparison of conventional crowns and a new all-ceramic system]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>1993</year>
<volume>21</volume>
<page-range>47-51</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hung]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[Hung]]></surname>
<given-names><![CDATA[KS]]></given-names>
</name>
<name>
<surname><![CDATA[Eick]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
<name>
<surname><![CDATA[Chappell]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Marginal fit of porcelain-fused-to-metal and two types of ceramic crown]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1990</year>
<volume>63</volume>
<page-range>26-31</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kokubo]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Ohkubo]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Tsumita]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Miyashita]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vult]]></surname>
<given-names><![CDATA[von Steyern P]]></given-names>
</name>
<name>
<surname><![CDATA[Fukushima]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical marginal and internal gaps of Procera AllCeram crowns]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>526-530</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
