<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-246X</journal-id>
<journal-title><![CDATA[Revista Facultad de Odontología Universidad de Antioquia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Fac Odontol Univ Antioq]]></abbrev-journal-title>
<issn>0121-246X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Antioquia ]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-246X2011000100007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Implantes cortos. Reporte de 30 implantes: Parte I: oseointegración]]></article-title>
<article-title xml:lang="en"><![CDATA[Short implant system. 30-implant report: Part I: osseointegration]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Arismendi]]></surname>
<given-names><![CDATA[Jorge Alberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cabrales]]></surname>
<given-names><![CDATA[Manuel]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Duque]]></surname>
<given-names><![CDATA[Jaiver Andrés]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castañeda]]></surname>
<given-names><![CDATA[Wilmer]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología grupo POPCAD]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[Medellín ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Antioquia Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<volume>22</volume>
<numero>2</numero>
<fpage>198</fpage>
<lpage>204</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-246X2011000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-246X2011000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-246X2011000100007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[INTRODUCCIÓN: este reporte clínico pretende presentar los resultados obtenidos con un sistema de implantes que modifica el protocolo convencional quirúrgico en cuanto a las revoluciones de fresado, no uso de irrigación, recolección del hueso nativo y opciones protésicas como la corona integrada al pilar, la cementación extraoral y la posición universal del pilar. En cuanto a su diseño se destaca el uso de implantes cortos, plataforma reducida, aletas laterales, conexión al pilar por cierre friccional y superficie alterada. MÉTODOS: se colocaron treinta implantes Bicon® de seis milímetros de longitud para restauración de diente único en veintidós pacientes. Se hizo el protocolo quirúrgico de acuerdo con las recomendaciones del fabricante y en dos fases quirúrgicas. Se hizo la cirugía de destape de cada implante y se cementaron todas las restauraciones metal-cerámicas. RESULTADOS: se reporta 100% de oseointegración de los implantes al momento de la cirugía de destape, con ausencia de movilidad o dolor durante la función, ausencia de exudado y normalidad de los tejidos blandos periimplantares; se reporta ausencia de radiolucidez en la evaluación radiográfica. CONCLUSIONES: en este estudio podemos concluir que con el protocolo quirúrgico modificado y el diseño del implante Bicon® (Bicon tm Dental Implants, Boston, MA) se logró el 100% de éxito en la oseointegración de treinta implantes cortos al momento de la cirugía de destape, con superficie alterada y plataforma reducida, colocados para la restauración de diente único en diferentes zonas de la cavidad oral.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[INTRODUCTION: the purpose of this clinical report is to present the collected results with an implant system that modifies the classical protocol regarding drilling speed, use of irrigation, native bone collecting and prosthetic options including crown integrated to the abutment, extraoral cementing of the crown and universal position of abutment screw. Regarding implant design, it&acute;s important to highlight the use of short implants, with reduced platform, lateral wings instead of screw threads, abutment connection by means of friction and modified implant surface. METHODS: 30 Bicon® implants, all six-mm of length, were placed in order to perform single tooth restorations in 22 patients. The surgical protocol was performed according to indications of the manufacturer in two surgical stages. The implants were uncovered and all metal-ceramic crowns were cemented. RESULTS: the percentage of osseointegration success was 100% at the time of uncovering, without pain or mobility during function, no signs of infection and healthy appearance of peri-implant tissues. There were no radiographic changes at the x-ray evaluation. CONCLUSION: considering the limitations of this study, it can be concluded that with the modified surgical protocol and the structural design of the Bicon® Implant (Bicon tmDental Implants, Boston, MA) a 100% osseointegration success was achieved on 30 implants with modified surface and reduced platform, placed in different areas of the oral cavity for single-tooth restoration.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[implantes cortos]]></kwd>
<kwd lng="es"><![CDATA[conexión interna]]></kwd>
<kwd lng="es"><![CDATA[ajuste por fricción]]></kwd>
<kwd lng="es"><![CDATA[oseointegración]]></kwd>
<kwd lng="en"><![CDATA[short implants]]></kwd>
<kwd lng="en"><![CDATA[internal connection]]></kwd>
<kwd lng="en"><![CDATA[frictional adjustment]]></kwd>
<kwd lng="en"><![CDATA[osseointegration]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <font size="2" face="Verdana">      <p align="right"><b>ART&Iacute;CULOS ORIGINALES DERIVADOS DE INVESTIGACI&Oacute;N</b></p>          <p>&nbsp;</p>       <p align="center"><font size="4" face="Verdana"><b>Implantes cortos. Reporte de 30 implantes. Parte I: oseointegraci&oacute;n<sup>1</sup></b></font></p>          <p>&nbsp;</p>           <p align="center"><font size="3" face="Verdana"><b>Short implant system. 30-implant report. Part I: osseointegration</b></font></p>           <p>&nbsp;</p>          <p>&nbsp;</p>           <p><b> Jorge Alberto Arismendi<sup>2</sup>; Manuel Cabrales<sup>3</sup>; Jaiver Andr&eacute;s Duque<sup>4</sup>; Wilmer Casta&ntilde;eda<sup>5</sup></b></p>      <p><sup>1</sup>Trabajo de tesis de grado como requisito parcial para optar al t&iacute;tulo de especialista cl&iacute;nico en Odontolog&iacute;a Integral del Adulto, &eacute;nfasis en Prostodoncia, Facultad de Odontolog&iacute;a, Universidad de Antioquia. Donaci&oacute;n de equipos, implantes y aditamentos prot&eacute;sicos de Bicon Dental Implants<sup>&reg;</sup>    ]]></body>
<body><![CDATA[<br>  <sup>2</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto. Profesor Titular, grupo POPCAD, Facultad de Odontolog&iacute;a, Universidad de Antioquia. Medell&iacute;n, Colombia. <a href="mailto:jorgearismendi@une.net.co">jorgearismendi@une.net.co</a>    <br>     <sup>3</sup> Odont&oacute;logo, especialista en Odontolog&iacute;a Integral del Adulto. Profesor asistente. Facultad de Odontolog&iacute;a, Universidad de Antioquia. Medell&iacute;n, Colombia    <br>  <sup>4</sup> Odont&oacute;logos, residentes Especialidad Cl&iacute;nica en Odontolog&iacute;a Integral del Adulto, &eacute;nfasis en Prostodoncia, Facultad de Odontolog&iacute;a, Universidad de Antioquia</p>      <p>&nbsp;</p>     <p>&nbsp;</p> <hr noshade>      <p><b>RESUMEN</b></p>           <p><b>INTRODUCCI&Oacute;N:</b> este reporte cl&iacute;nico pretende presentar los resultados obtenidos con un sistema de implantes que modifica el protocolo convencional quir&uacute;rgico en cuanto a las revoluciones de fresado, no uso de irrigaci&oacute;n, recolecci&oacute;n del hueso nativo y opciones prot&eacute;sicas como la corona integrada al pilar, la cementaci&oacute;n extraoral y la posici&oacute;n universal del pilar. En cuanto a su dise&ntilde;o se destaca el uso de implantes cortos, plataforma reducida, aletas laterales, conexi&oacute;n al pilar por cierre friccional y superficie alterada.    <br>  <b>M&Eacute;TODOS:</b> se colocaron treinta implantes Bicon<sup>&reg;</sup> de seis mil&iacute;metros de longitud para restauraci&oacute;n de diente &uacute;nico en veintid&oacute;s pacientes. Se hizo el protocolo quir&uacute;rgico de acuerdo con las recomendaciones del fabricante y en dos fases quir&uacute;rgicas. Se hizo la cirug&iacute;a de destape de cada implante y se cementaron todas las restauraciones metal-cer&aacute;micas.    <br>  <b>RESULTADOS:</b> se reporta 100% de oseointegraci&oacute;n de los implantes al momento de la cirug&iacute;a de destape, con ausencia de movilidad o dolor durante la funci&oacute;n, ausencia de exudado y normalidad de los tejidos blandos periimplantares; se reporta ausencia de radiolucidez en la evaluaci&oacute;n radiogr&aacute;fica.    <br>  <b>CONCLUSIONES:</b> en este estudio podemos concluir que con el protocolo quir&uacute;rgico modificado y el dise&ntilde;o del implante Bicon<sup>&reg;</sup> (Bicon<sup>tm</sup> Dental Implants, Boston, MA) se logr&oacute; el 100% de &eacute;xito en la oseointegraci&oacute;n de treinta implantes cortos al momento de la cirug&iacute;a de destape, con superficie alterada y plataforma reducida, colocados para la restauraci&oacute;n de diente &uacute;nico en diferentes zonas de la cavidad oral.</p>      ]]></body>
<body><![CDATA[<p><b>Palabras clave:</b> implantes cortos, conexi&oacute;n interna, ajuste por fricci&oacute;n, oseointegraci&oacute;n.</p>   <hr noshade>           <p><b>ABSTRACT</b></p>           <p><b>INTRODUCTION:</b> the purpose of this clinical report is to present the collected results with an implant system that modifies the classical protocol regarding drilling speed, use of irrigation, native bone collecting and prosthetic options including crown integrated to the abutment, extraoral cementing of the crown and universal position of abutment screw. Regarding implant design, it&acute;s important to highlight the use of short implants, with reduced platform, lateral wings instead of screw threads, abutment connection by means of friction and modified implant surface.    <br>  <b>METHODS:</b> 30 Bicon<sup>&reg;</sup> implants, all six-mm of length, were placed in order to perform single tooth restorations in 22 patients. The surgical protocol was performed according to indications of the manufacturer in two surgical stages. The implants were uncovered and all metal-ceramic crowns were cemented.    <br>  <b>RESULTS:</b> the percentage of osseointegration success was 100% at the time of uncovering, without pain or mobility during function, no signs of infection and healthy appearance of peri-implant tissues. There were no radiographic changes at the x-ray evaluation.</p>  <b>CONCLUSION:</b> considering the limitations of this study, it can be concluded that with the modified surgical protocol and the structural design of the Bicon<sup>&reg;</sup> Implant (Bicon<sup>tm</sup>Dental Implants, Boston, MA) a 100% osseointegration success was achieved on 30 implants with modified surface and reduced platform, placed in different areas of the oral cavity for single-tooth restoration.</p>      <p><b>Key words:</b> short implants, internal connection, frictional adjustment, osseointegration.</p>  <hr noshade>     <p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>INTRODUCCI&Oacute;N </b></font></p>      <p>El proceso de oseointegraci&oacute;n se ha consolidado como un evento predecible que se mantiene a largo plazo, sin ruptura biol&oacute;gica bajo cargas funcionales. Los estudios de seguimiento cl&iacute;nico y radiogr&aacute;fico reportan tasas de &eacute;xito cercanas al 96% en promedio, sin diferencias en cuanto al sistema de implante se refiere.<sup>1-4</sup></p>      ]]></body>
<body><![CDATA[<p>Inicialmente el sistema Br&aring;nemark<sup>&reg;</sup> (Nobel Biocare, G&ouml;teborg, Sweden) propuso un protocolo quir&uacute;rgico de oseointegraci&oacute;n con tiempos de cicatrizaci&oacute;n de cuatro meses para la mand&iacute;bula y seis meses para el maxilar, una fase quir&uacute;rgica en dos etapas e implantes roscados tipo tornillo de superficie lisa. Las tasas de supervivencia para estos implantes a nueve a&ntilde;os eran del 81% para maxilar y 91 para mand&iacute;bula.<sup>5</sup> El implante ITI<sup>&reg;</sup> (Institut Straumann AG, Waldenburg, Switzerland) introdujo al mercado un dise&ntilde;o con superficie modificada y una sola fase quir&uacute;rgica para hacer m&aacute;s eficiente el proceso de cicatrizaci&oacute;n y poder ofrecer tratamientos m&aacute;s cortos basados en la posibilidad de carga inmediata. Este sistema reportaba una tasa de supervivencia del 91,7% a seis a&ntilde;os.<sup>6, 7</sup></p>      <p>Para los implantes Br&aring;nemark<sup>&reg;</sup> y sus similares se report&oacute; p&eacute;rdida &oacute;sea marginal de 1,5 a 2 mm en el primer a&ntilde;o y una tasa de 0,2 mm en los a&ntilde;os siguientes. <sup>8</sup> La p&eacute;rdida &oacute;sea marginal se ha atribuido principalmente a la transmisi&oacute;n de fuerzas desde el pilar a trav&eacute;s de la conexi&oacute;n atornillada y a la contaminaci&oacute;n bacteriana en la interfase implantepilar. <sup>9</sup> Las complicaciones prot&eacute;sicas por fractura o aflojamiento del tornillo aceleran la destrucci&oacute;n &oacute;sea.<sup>10, 11</sup> La conexi&oacute;n sin tornillo prot&eacute;sico podr&iacute;a evitar estos inconvenientes, mejorar la transmisi&oacute;n de fuerzas hacia el hueso y brindar un selle as&eacute;ptico para mantener la salud de los tejidos.<sup>12-15</sup></p>      <p>En los casos de colocaci&oacute;n de implantes en zonas de baja calidad &oacute;sea (hueso tipo IV), con corticales delgadas, baja densidad trabecular y poca resistencia interna, situaci&oacute;n muy com&uacute;n en la zona posterior del maxilar, se reportan altas tasas de fracasos. En una evaluaci&oacute;n a cinco a&ntilde;os de 1.054 implantes tipo Br&aring;nemark<sup>&reg;</sup> (superficie lisa y titanio comercialmente puro), 102 (10% de ellos) colocados en hueso tipo IV, se observ&oacute; fracaso en el 35% para este grupo, mientras que para el resto de implantes, colocados en hueso tipos I, II y III, el fracaso fue del 3%.<sup>16</sup> La recomendaci&oacute;n final que aparece en este trabajo es que se busque la manera de predeterminar la presencia de hueso tipo IV en la evaluaci&oacute;n prequir&uacute;rgica como m&eacute;todo para disminuir la tasa de fracaso en estas localizaciones. Otras posibles recomendaciones fueron: hacer menor fresado en el lecho &oacute;seo, usar implantes de mayor longitud, colocar mayor n&uacute;mero de implantes en la zona y acortar las pr&oacute;tesis con extensi&oacute;n distal libre.<sup>17</sup> Tambi&eacute;n se recomend&oacute; el anclaje bicortical de los implantes y mayor tiempo de cicatrizaci&oacute;n.<sup>18</sup> El sistema de implantes ITI<sup>&reg;</sup> propuso la superficie modificada TPS<sup>&reg;</sup> (Titanium Plasma Spray) para mejorar los resultados de oseointegraci&oacute;n en dichas zonas con una tasa de supervivencia del 95,6%.<sup>19</sup></p>      <p>En 1985 la compa&ntilde;&iacute;a Bicon<sup>&reg;</sup> (Boston, MA) introduce al mercado implantes de 8,0 mm de longitud con caracter&iacute;sticas muy diferentes a los implantes basados en el dise&ntilde;o Br&aring;nemark<sup>&reg;</sup>. Las tasas de supervivencia reportadas en estudios retrospectivos alcanzan el 99,7% para implantes menores a 10 mm de longitud con muestras que superan los 2.000 implantes.<sup>20</sup> Para estudios cl&iacute;nicos con implantes cortos de superficie alterada de 6,0 mm de longitud basados en el dise&ntilde;o Bicon<sup>&reg;</sup> se reporta una tasa de supervivencia del 92,2%.Sup&gt;21</p> El protocolo quir&uacute;rgico hace algunas variaciones con respecto a los dos sistemas descritos anteriormente en cuanto a la posici&oacute;n del implante, las revoluciones de fresado, no uso de irrigaci&oacute;n, recolecci&oacute;n del hueso nativo y opciones prot&eacute;sicas como la corona integrada al pilar, la cementaci&oacute;n extraoral y la posici&oacute;n universal del pilar. En cuanto a su dise&ntilde;o se destaca el uso de plataforma reducida, aletas laterales en reemplazo de las roscas tradicionales, conexi&oacute;n al pilar por cierre friccional y superficie alterada.<sup>22</sup></p>      <p>Este estudio pretende reportar en su primera parte los resultados de oseointegraci&oacute;n de un sistema de implantes cortos de acuerdo con los par&aacute;metros cl&iacute;nicos y radiogr&aacute;ficos convencionales.</p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>MATERIALES Y M&Eacute;TODOS</b></font></p>      <p><b>Dise&ntilde;o del estudio y muestra</b></p>      <p>Este estudio cl&iacute;nico experimental con un solo grupo consta de una muestra de treinta implantes Bicon<sup>&reg;</sup> (Bicon<sup>tm</sup> Dental Implants, Boston, MA) (n = 30) con di&aacute;metro de 4,5 mm (n = 27) y 5,0 mm (n = 3), longitud de seis mil&iacute;metros, geometr&iacute;a c&oacute;nica, cavidad conectora de 3 mm, plataforma reducida, conexi&oacute;n friccional a 1,5o, dise&ntilde;o en aleta no roscado, paso recto entre aletas y superficie modificada (recubierto con hidroxiapatita). Los pacientes para este estudio fueron remitidos de cl&iacute;nicas de pregrado de la Facultad de Odontolog&iacute;a de la Universidad de Antioquia y pacientes particulares con necesidad de restauraci&oacute;n implanto-soportada de diente &uacute;nico en cualquier zona de la boca. Los criterios de exclusi&oacute;n fueron pacientes con requerimiento de rehabilitaci&oacute;n extensa y pacientes con compromiso sist&eacute;mico o enfermedad periodontal activa.</p>      <p>La evaluaci&oacute;n cl&iacute;nica se hizo de acuerdo con tres variables para cada implante: dolor, movilidad y exudado. Las variables, por ser de naturaleza cualitativa, se codificaron como presencia o ausencia. Basados en el consenso de Pisa, se estableci&oacute; el estado de cada implante categoriz&aacute;ndolo seg&uacute;n las condiciones cl&iacute;nicas encontradas:<sup>23</sup></p>      ]]></body>
<body><![CDATA[<p><b>Grupo de &eacute;xito (salud &oacute;ptima):</b> ausencia de dolor, no movilidad, p&eacute;rdida &oacute;sea marginal menor de 2 mm despu&eacute;s de la cirug&iacute;a inicial y ausencia de exudado.</p>      <p><b>Grupo de supervivientes satisfactorios:</b> ausencia de dolor, no movilidad, 2-4 mm de p&eacute;rdida &oacute;sea y sin historia de exudado.</p>      <p><b>Grupo de supervivientes comprometidos:</b> dolor durante funci&oacute;n, sin movilidad, p&eacute;rdida &oacute;sea mayor de 4 mm, profundidad sondable mayor de 7 mm e historia de exudado.</p>      <p><b>Grupo de fracaso:</b> dolor durante la funci&oacute;n, movilidad, perdida &oacute;sea mayor a la mitad de la longitud del implante, historia de exudado o ausencia del implante.</p>      <p>La perdida &oacute;sea marginal no fue tenida en cuenta para cualificar y categorizar los implantes en este reporte porque la maduraci&oacute;n del hueso alrededor de la plataforma en un implante sumergido no es par&aacute;metro significativo sino hasta el momento del destape y la carga prot&eacute;sica. Estos datos se tendr&aacute;n en cuenta en un pr&oacute;ximo reporte.</p>      <p><b>Recolecci&oacute;n de datos</b></p>      <p>Por medio de un muestreo no probabil&iacute;stico por conveniencia se seleccionaron los pacientes con necesidad de restauraci&oacute;n implanto-soportada de diente &uacute;nico. Se revisaron 50 pacientes de la Facultad de Odontolog&iacute;a procedentes de cl&iacute;nicas de pregrado y pacientes externos. De estos, 22 pacientes se incluyeron en el estudio, 6 hombres y 16 mujeres, con promedio de edad de 36 a&ntilde;os (intervalo: 17-65). Se hicieron los procedimientos de primera fase quir&uacute;rgica y, despu&eacute;s de tres meses para mand&iacute;bula y cuatro meses para maxilar, se hicieron las cirug&iacute;as de la fase de destape para moldear el tejido blando con el pilar de cicatrizaci&oacute;n. Para la recolecci&oacute;n de datos se tomaron registros cl&iacute;nicos de dolor y movilidad el d&iacute;a del destape y el d&iacute;a de la cementaci&oacute;n de la restauraci&oacute;n prot&eacute;sica (la restauraci&oacute;n final se cement&oacute; sobre cada implante tres meses despu&eacute;s de la cirug&iacute;a de destape). Para cada implante se registraba la codificaci&oacute;n de cada una de las tres variables. Adem&aacute;s, se tomaron radiograf&iacute;as antes de la colocaci&oacute;n del implante, una segunda radiograf&iacute;a inmediatamente despu&eacute;s de la colocaci&oacute;n del implante y una tercera radiograf&iacute;a cuatro meses despu&eacute;s en la cirug&iacute;a de destape para posterior evaluaci&oacute;n radiogr&aacute;fica. Todas las radiograf&iacute;as fueron estandarizadas en cuanto a angulaci&oacute;n y equipos para lo cual se confeccion&oacute; una f&eacute;rula para cada paciente.</p>      <p><b>An&aacute;lisis cl&iacute;nico.</b> La evaluaci&oacute;n cl&iacute;nica fue registrada en un formato f&iacute;sico en dos momentos, el d&iacute;a de la cirug&iacute;a de destape y el d&iacute;a de la toma de impresi&oacute;n. La integridad de los tejidos periimplantares fue evaluada cualitativamente bajo el concepto de ausencia de s&iacute;ntomas adversos.</p>      <p>Para la cirug&iacute;a de colocaci&oacute;n del implante y el destape se cumplieron secuencialmente los pasos que los protocolos del sistema especifican. Se levant&oacute; un colgajo de base amplia sobre lingual o palatino para garantizar acceso y visibilidad, con una fresa piloto en un contr&aacute;ngulo Bicon<sup>&reg;</sup> (Bicon<sup>tm</sup> Dental Implants, Boston, MA) con relaci&oacute;n 400:1 a 50 RPM. Se perfora hasta la m&aacute;xima profundidad necesaria con la angulaci&oacute;n adecuada para permitir asentar el implante a 3-5 mm por debajo de la cresta &oacute;sea. Las fresas presentan unas marcas indicadoras de profundidad (8, 11, 14, 18 mm) que sirven para guiar el procedimiento de fresado en sentido vertical. Se aumenta el di&aacute;metro del lecho quir&uacute;rgico con una fresa en forma mec&aacute;nica o manual; los di&aacute;metros de las fresas se corresponden con los di&aacute;metros de los implantes. Las caracter&iacute;sticas del procedimiento de fresado para preparar el lecho del implante son:</p>      <p>No se usa refrigeraci&oacute;n por agua (no se recomienda porque diluye la sangre y el hueso aut&oacute;geno retirado del lecho). Dicho hueso se recolecta en un recipiente est&eacute;ril para ser usado despu&eacute;s de ser impactado el implante en defectos &oacute;seos resultantes o simplemente para cubrir lateralmente zonas de la plataforma del implante si quedaran expuestas.</p>  <ul>     ]]></body>
<body><![CDATA[<li>    <p> El fresado no excede las 50 revoluciones por minuto.</p></li>     <li>    <p>Emplea la t&eacute;cnica de fresado a dos manos (una mano gu&iacute;a la fresa mientras la otra aplica presi&oacute;n vertical para profundizar el corte).</p></li>     <li>    <p>El hueso se recolecta dos o tres veces en cada cambio de fresa procurando fresar en un lecho limpio de restos &oacute;seos.</p></li>     <li>    <p>Se deben insertar las fresas 3 a 5 mm m&aacute;s de profundidad que la marca correspondiente al implante seleccionado. Esto garantiza que se pueda impactar y que el implante quede subcrestal. Se verifica la retenci&oacute;n mec&aacute;nica del implante con el insertador. Se hace hemostasia, se limpia la cavidad conectora, se coloca el tap&oacute;n de selle con un insertador roscado similar a una lima y se impacta para generar selle y estabilidad de la conexi&oacute;n.</p></li>     <li>    <p>Una vez asentado el implante con su respectivo tap&oacute;n de selle se cubren los espacios alrededor del implante con el hueso aut&oacute;logo recolectado en la preparaci&oacute;n del lecho, el cual se empaca muy cuidadosamente alrededor del tap&oacute;n de selle y el bisel de la plataforma del implante.</p></li>     ]]></body>
<body><![CDATA[<li>    <p>Finalmente, los tejidos se afrontan mediante suturas y se esperan tres meses en mand&iacute;bula y cuatro meses en maxilar. La cirug&iacute;a de destape se hace una vez se cumplan los tiempos de cicatrizaci&oacute;n estipulados en el protocolo.</p></li>     </ul>      <p><b>An&aacute;lisis de datos</b></p>      <p>Se hizo un an&aacute;lisis univariado para todas las variables cualitativas: dolor, movilidad y exudado.</p>      <p>En la <a href="#t1">tabla 1</a> se presenta la distribuci&oacute;n de los implantes Bicon<sup>&reg;</sup> colocados en este estudio seg&uacute;n genero, ubicaci&oacute;n y zona de la cavidad oral.</p>      <p align="center"><a name="t1"><img src=/img/revistas/rfoua/v22n2/v22n2a07t1.jpg></a> </p>      <p>La <a href="#t2">tabla 2</a> presenta la distribuci&oacute;n de los implantes de acuerdo con la zona del diente que se necesita reemplazar.</p>       <p align="center"><a name="t2"><img src=/img/revistas/rfoua/v22n2/v22n2a07t2.jpg></a> </p>      <p>&nbsp;</p>      ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana"><b>RESULTADOS</b></font></p>      <p>El 100% de los implantes colocados se encuentran satisfactoriamente oseointegrados. Los tejidos blandos y duros adyacentes de cada implante codifican negativamente para presencia de patolog&iacute;a. La variable movilidad es negativa para el 100% de los implantes y, en general, el estado de los implantes en cuanto a oseointegraci&oacute;n se refiere es exitosa, cumpliendo los par&aacute;metros establecidos para el grupo de &eacute;xito (salud &oacute;ptima), as&iacute;: prueba individual de movilidad negativa, ausencia de dolor y ausencia de exudado.</p>      <p>Las variables evaluadas en esta investigaci&oacute;n se discriminan en las <a href="#t3">tablas 3</a> y <a href="#t4">4</a>, seg&uacute;n la codificaci&oacute;n para variables nominales.</p>      <p align="center"><a name="t3"><img src=/img/revistas/rfoua/v22n2/v22n2a07t3.jpg></a> </p>      <p align="center"><a name="t4"><img src=/img/revistas/rfoua/v22n2/v22n2a07t4.jpg></a> </p>      <p>En consecuencia, la ausencia de signos patol&oacute;gicos de los tejidos periimplantares durante las evaluaciones cl&iacute;nicas determinan en este estudio la oseointegraci&oacute;n para el 100% de implantes colocados bajo el protocolo quir&uacute;rgico del sistema Bicon<sup>&reg;</sup> (Boston, MA). Esta informaci&oacute;n se corrobora con la evaluaci&oacute;n radiogr&aacute;fica y la estabilidad lograda en las restauraciones prot&eacute;sicas (<a href="#f1">figura 1</a>).</p>      <p align="center"><a name="f1"><img src=/img/revistas/rfoua/v22n2/v22n2a07f1.jpg></a> </p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>DISCUSI&Oacute;N</b></font></p>      <p>El protocolo quir&uacute;rgico validado por el sistema Br&aring;nemark <sup>&reg;</sup> ha demostrado a trav&eacute;s del tiempo ser fiable al lograr tasas exitosas en cuanto a oseointegraci&oacute;n se refiere. En este protocolo se sugiri&oacute; respetar los tiempos de cicatrizaci&oacute;n de seis y cuatro meses para maxilar y mand&iacute;bula respectivamente.<sup>24</sup> El sistema ITI<sup>&reg;</sup> vari&oacute; el protocolo quir&uacute;rgico convencional de dos fases quir&uacute;rgicas para ofrecer a los pacientes la opci&oacute;n de recibir pr&oacute;tesis inmediata. Para ello se present&oacute; un dise&ntilde;o de implante que garantizara una oseointegraci&oacute;n eficiente y predecible a corto plazo. La superficie alterada y la geometr&iacute;a c&oacute;nica le proporcionaban al implante una estabilidad primaria que aseguraba una retenci&oacute;n mec&aacute;nica para la posterior estabilidad secundaria.<sup>25</sup> El sistema Bicon<sup>&reg;</sup> (Bicon<sup>tm</sup> Dental Implants, Boston, MA) ofrece un protocolo quir&uacute;rgico totalmente distinto y una geometr&iacute;a de implante particular que lo diferencian de los dem&aacute;s sistemas. En este sentido el protocolo quir&uacute;rgico para la colocaci&oacute;n de sus implantes retoma la opci&oacute;n del protocolo Br&aring;nemark de dos fases quir&uacute;rgicas, pero la cirug&iacute;a como tal es completamente distinta; en ella no hay refrigeraci&oacute;n por la baja revoluci&oacute;n del fresado con el objetivo de ser lo menos traum&aacute;tico y recolectar el hueso nativo que servir&aacute; para llenar espacios alrededor de la plataforma reducida. La ubicaci&oacute;n del implante subcrestalmente y la impactaci&oacute;n del pilar prot&eacute;sico permiten funcionar como un solo cuerpo garantizando est&eacute;tica y estabilidad de los tejidos periimplantares. Las particularidades en el dise&ntilde;o del implante son: plataforma reducida que permite aposici&oacute;n &oacute;sea, conservaci&oacute;n del nivel &oacute;seo marginal y estabilidad del tejido blando; superficie alterada con hidroxiapatita para hacer m&aacute;s eficiente el proceso de oseointegraci&oacute;n; inserci&oacute;n del implante por impacto para lograr que las aletas queden atrapadas en el hueso y aumentar la retenci&oacute;n primaria del implante; conexi&oacute;n interna friccional que promueve la salud de los tejidos periimplantares por su selle as&eacute;ptico y la estabilidad del hueso marginal al controlar las fuerzas laterales nocivas; di&aacute;metro amplio que aumenta el &aacute;rea de contacto y favorece la distribuci&oacute;n de fuerzas no axiales; longitudes cortas que favorecen su implantaci&oacute;n en zonas de dif&iacute;cil acceso y problemas en altura &oacute;sea como las zonas posteriores de la mand&iacute;bula y del maxilar.</p>      ]]></body>
<body><![CDATA[<p>Este estudio demuestra que el protocolo quir&uacute;rgico modificado del sistema Bicon<sup>&reg;</sup> logra resultados satisfactorios para la oseointegraci&oacute;n de implantes cortos con superficie alterada y di&aacute;metro amplio. Los resultados del 100% de implantes cortos Bicon<sup>&reg;</sup> oseointegrados categorizados como &eacute;xito (salud &oacute;ptima) sustentan la validez del protocolo quir&uacute;rgico y evidencian los beneficios del dise&ntilde;o del implante cuyas particularidades hacen predecible el proceso de oseointegraci&oacute;n.</p>      <p>La superficie alterada ha demostrado beneficios a corto plazo sobre la superficie lisa, optimizando los tiempos de cicatrizaci&oacute;n y aumentado la predecibilidad del proceso de oseointegraci&oacute;n incluso en zonas de hueso de mala calidad.<sup>26, 27</sup> La superficie alterada (HA) del implante Bicon<sup>&reg;</sup> (Boston, MA) acelera la adsorci&oacute;n de prote&iacute;nas s&eacute;ricas, especialmente la fibronectina, la cual va a promover la retenci&oacute;n del co&aacute;gulo y favorece el reclutamiento y proliferaci&oacute;n de las dem&aacute;s c&eacute;lulas y mol&eacute;culas que promueven la cicatrizaci&oacute;n.<sup>28, 29</sup> El contacto hueso implante (BIC) aumenta gracias a la matriz de hidroxiapatita en la superficie. La energ&iacute;a superficial y la humectaci&oacute;n de la superficie aumentan el &aacute;ngulo de contacto entre superficie implantar y c&eacute;lulas. Todos estos eventos aceleran el proceso de oseointegraci&oacute;n y facilitan el posoperatorio para el paciente.<sup>30</sup></p>      <p>Los resultados de oseointegraci&oacute;n logrados con los treinta implantes cortos Bicon<sup>&reg;</sup> colocados en este estudio, en t&eacute;rminos de estabilidad cl&iacute;nica, normalidad de tejidos blandos periimplantares y ausencia de radiolucidez para el 100% de ellos, son comparables con los resultados logrados en otros reportes con 432 implantes Bicon<sup>&reg;</sup> colocados.<sup>31</sup> Los implantes cortos, acompa&ntilde;ados de otras variables como el aumento en el di&aacute;metro, la superficie alterada, hueso de buena calidad y oclusi&oacute;n estable, tienen resultados predecibles a largo plazo y presentan m&iacute;nimas complicaciones.<sup>32-34</sup></p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>CONCLUSI&Oacute;N</b></font></p>      <p>Bajo las limitaciones de este estudio podemos concluir que con el protocolo quir&uacute;rgico modificado y el dise&ntilde;o del implante Bicon<sup>&reg;</sup> (Bicon<sup>tm</sup> Dental Implants, Boston, MA) se logr&oacute; el 100% de &eacute;xito en cuanto a oseointegraci&oacute;n de treinta implantes cortos con superficie alterada y plataforma reducida al momento de la cirug&iacute;a de destape, colocados en diferentes zonas de la cavidad oral.</p>      <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>REFERENCIAS</b></font></p>      <!-- ref --><p>1. Eckert SE, Choi YG, S&aacute;nchez AR, Koka S. Comparison of dental implant system: quality of clinical evidence and prediction of 5-year survival. Int J Oral Maxillofac Implants 2005; 20(3): 406-415.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0121-246X201100010000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Schnitman PA, W&ouml;hrle PS, Rubenstein JE, Da Silva JS, Wang NH. Ten year results for Br&aring;nemark implants immediately loaded with fixed protheses at implant placement. Int J Oral Maxillofac Implants 1997; 12(4): 495-503.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0121-246X201100010000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3. Lekholm U, Gunne J, Henry P, Higuchi K, Lind&eacute;n U, Bergstr&ouml;m C, van Steenberghe D. Survival of the Br&aring;nemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999; 14(5): 639-645.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0121-246X201100010000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. Schmitt A, Zarb GA. The longitudinal and clinical effectiveness of osseointegrated dental implant for single-tooth replacement. Int J Prosthodont 1993; 6(2): 197-202.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0121-246X201100010000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. Adell R, Lekholm U, Rockler B, Br&aring;nemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10(6): 387-416.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0121-246X201100010000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. Pohler OE, Swiss screw: concept and experimental work. J Oral Implantol 1986; 12(3): 338-349.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0121-246X201100010000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. Assael LA. The nonsubmerged osseointegrated dental implant. Dent Clin North Am 1998; 42(1): 203-221.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0121-246X201100010000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. Albrektsson T. Hard tissue implant interface. Aust Dent J 2008; 53 Supl 1: S34-S38.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0121-246X201100010000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. Proff P, Steinmetz I, Bayerlein T, Dietze S, Fanghanel J, Gedrange T. Bacterial colonization of interior implants threads with and without sealing. Folia Morphol 2006; 65(1): 75-77.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0121-246X201100010000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10. Shepherd NJ. Affordable implant prosthetics using a screwless implant system. J Am Dent Assoc 1998; 129(12): 1732-1738.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0121-246X201100010000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11. Binon PP. The external hexagonal interface and screw-joint stability: a primer on threaded fasteners. Quintessence Dent Technol 2000; 23: 91-105.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0121-246X201100010000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12. Binon PP. Implants and components: entering the new millenium. Int J Oral Maxillofac Implants 2000; 15(1): 76-93.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0121-246X201100010000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13. Mangano C, Bartolucci EG. Single tooth replacement by Morse taper connection implants: a retrospective study of 80 implants. Int J Oral Maxillofac 2001; 16(5): 675-680.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0121-246X201100010000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14. Dibart S. Warbigton M, Su MF, Skobe Z. In vitro evaluation of implant-abutment bacterial seal: the locking taper system. J Oral Maxillofac Implants 2005; 20(5): 732-737.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0121-246X201100010000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15. Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997; 8(4): 290-298.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0121-246X201100010000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16. Jaffin RA, Berman CL. The excessive loss of Branemark fixture in type IV bone: a 5 year analysis. J Periodontol 1991; 62(1): 2-4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0121-246X201100010000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17. Brunski J. Biocompatibility, biofunctionality and biomechanics of dental implants. En: Block MS, Kent JN, Guerra L, Fletcher J. Implants in dentistry. Philadelphia: Saunders; 1997. p. 63-71.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0121-246X201100010000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18. Bahat O. Br&aring;nemark system implants in posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants 2000; 15(5): 646-653.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0121-246X201100010000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19. De Leonardis D. Garg AK. Pecora GE. Osseointegration of rough acid-etched Titanium implants: 5 year follow up of 100 minimatic implants. Int J Oral Maxillofac Implants 1999; 14(13): 384-391.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0121-246X201100010000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20. Gentile MA, Chuang SK, Dodson TB. Survival estimates and risk factor for failure with 6 x 5.7 mm implants. Int J Oral Maxillofac Implants 2005; 20(6): 930-937.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0121-246X201100010000700020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21. Fugazzotto PA. Shorter implants in clinical practice: rationale and treatment results. Int J Oral Maxillofac Implants 2008; 23(3): 487-496.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000111&pid=S0121-246X201100010000700021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22. Leonard G, Coelho P, Polyzois I, Stassen L, Claffey N. A study of the bone healing kinetics of plateau versus screw root design titanium dental implants. Clin Oral Impl Res 2009; 20(3): 232-239.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0121-246X201100010000700022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23. Misch CE, Perel ML, Wang HL, Sammartino G, Galindo- Moreno P, Trisi P et al. Implant success, survival, and failure: the international congress of oral implantologists (ICOI) Pisa, Consensus conference. Implant Dent 2008; 17: 5-15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000113&pid=S0121-246X201100010000700023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>24. Adell R, Erickson B, Lekholm U, Br&aring;nemark PI. A longterm follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990; 5: 347-359.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0121-246X201100010000700024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>25. Buser D, Mericske-Stern R, Bernard JP, Behneke N, Hirt HP, Belser UC et al. Long-term evaluation of non submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implant Res 1997; 8(3): 161-172.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000115&pid=S0121-246X201100010000700025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>26. Arismendi J, Agudelo L, Ospina A. Implantes de superf&iacute;cie lisa o rugosa: una decisi&oacute;n cl&iacute;nica. Rev Int Protes Estomatol 2004; 6(1): 9-15.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0121-246X201100010000700026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>27. Sykaras N, Lacopino AM, Marker VA, Triplett RG, Woody RD. Implant materials, designs and surface topographies; their effect on osseointegration. A literature review. Int J Oral Maxillofac Implants 2000; 15(5): 675-690.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000117&pid=S0121-246X201100010000700027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>28. Davies JE. Mechanisms of Endosseous integration. Int J Prosthodont 1998; 11(5): 391-401.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0121-246X201100010000700028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>29. Kanagaraja S, Wenneberg A, Eriksson, Nygren H. Cellular reactions and bone apposition to titanium surface with different surface roughness and oxide thickness cleaned by oxidation. Biomaterials 2001; 22(13): 1809-1818.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000119&pid=S0121-246X201100010000700029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>30. Abrahamsson I, Zitzmann NU, Berglundh T, Wennerberg A, Lindhe J. Bone and soft tissue integration to titanium implants with different surface topography: an experimental study in the dog. Int J Oral Maxillofac Implants 2001; 16(3): 323-332.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0121-246X201100010000700030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>31. Muftu A, Chapman RJ, Replacing posterior teeth with freestanding implants: four- year prosthodontic results of a prospective study. J Am Dent Assoc 1998; 129: 1097-1102.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000121&pid=S0121-246X201100010000700031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>32. Das Neves FD, Fones D, Bernardes SR. do Prado CJ, Neto AJ. Short Implants-an analysis of longitudinal studies. Int J Oral Maxillofac Implants 2006; 21(1): 86-93.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0121-246X201100010000700032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>33. Tawil G, Younan R. Clinical Evaluation of Short, machinedsurface implants followed for 12 to 92 months. Int J Oral Maxillofac Implants 2003; 18(6): 894-901.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0121-246X201100010000700033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>34. Romeo E, Ghisolfi M, Rozza R, Chiapasco M, Lops D. Short (8-mm) dental implants in the rehabilitation of partial and complete edentulism: a 3-to 14-year longitudinal study. Int J Prosthodont 2006; 19(6): 586-592.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0121-246X201100010000700034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>     <p>&nbsp;</p>      <p><b>RECIBIDO: NOVIEMBRE 11/2010 - ACEPTADO: MARZO 15/2011</b></p>      <p>&nbsp;</p>     <p>&nbsp;</p>      <p><font size="2" face="Verdana"><b>CORRESPONDENCIA</b></font></p>      <p>Jorge Alberto Arismendi    <br> Facultad de Odontolog&iacute;a    ]]></body>
<body><![CDATA[<br> Universidad de Antioquia    <br> Correo electr&oacute;nico:    <br> <a href="mailto:jorgearismendi@une.net.co">jorgearismendi@une.net.co</a></p>      <p>Arismendi JA, Cabrales M, Duque JA, Casta&ntilde;eda WR. Implantes cortos. Reporte de 30 implantes. Parte I: oseointegraci&oacute;n. Rev Fac Odontol Univ Antioq 2011; 22(2): 198-204.</p>       <p>Arismendi JA, Cabrales M, Duque JA. Casta&ntilde;eda WR, Short implant system. 30-implant report. Part I: osseointegration. Rev Fac Odontol Univ Antioq 2011; 22(2): 198-204.</p>   </font>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eckert]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[YG]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Koka]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of dental implant system: quality of clinical evidence and prediction of 5-year survival]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2005</year>
<volume>20</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>406-415</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schnitman]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Wöhrle]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
<name>
<surname><![CDATA[Rubenstein]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Da]]></surname>
<given-names><![CDATA[Silva JS]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[NH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ten year results for Brånemark implants immediately loaded with fixed protheses at implant placement]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1997</year>
<volume>12</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>495-503</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lekholm]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Gunne]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Henry]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Higuchi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Lindén]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Bergström]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[van]]></surname>
<given-names><![CDATA[Steenberghe]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1999</year>
<volume>14</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>639-645</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schmitt]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zarb]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The longitudinal and clinical effectiveness of osseointegrated dental implant for single-tooth replacement]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>1993</year>
<volume>6</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>197-202</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Adell]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Lekholm]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Rockler]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Brånemark]]></surname>
<given-names><![CDATA[PI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A 15-year study of osseointegrated implants in the treatment of the edentulous jaw]]></article-title>
<source><![CDATA[Int J Oral Surg]]></source>
<year>1981</year>
<volume>10</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>387-416</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pohler]]></surname>
<given-names><![CDATA[OE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Swiss screw: concept and experimental work]]></article-title>
<source><![CDATA[J Oral Implantol]]></source>
<year>1986</year>
<volume>12</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>338-349</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Assael]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The nonsubmerged osseointegrated dental implant]]></article-title>
<source><![CDATA[Dent Clin North Am]]></source>
<year>1998</year>
<volume>42</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>203-221</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albrektsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hard tissue implant interface]]></article-title>
<source><![CDATA[Aust Dent J]]></source>
<year>2008</year>
<volume>53</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>S34-S38</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Proff]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Steinmetz]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bayerlein]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Dietze]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fanghanel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gedrange]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial colonization of interior implants threads with and without sealing]]></article-title>
<source><![CDATA[Folia Morphol]]></source>
<year>2006</year>
<volume>65</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>75-77</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shepherd]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Affordable implant prosthetics using a screwless implant system]]></article-title>
<source><![CDATA[J Am Dent Assoc]]></source>
<year>1998</year>
<volume>129</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1732-1738</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Binon]]></surname>
<given-names><![CDATA[PP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The external hexagonal interface and screw-joint stability: a primer on threaded fasteners]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2000</year>
<volume>23</volume>
<page-range>91-105</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Binon]]></surname>
<given-names><![CDATA[PP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implants and components: entering the new millenium]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2000</year>
<volume>15</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>76-93</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mangano]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bartolucci]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Single tooth replacement by Morse taper connection implants: a retrospective study of 80 implants]]></article-title>
<source><![CDATA[Int J Oral Maxillofac]]></source>
<year>2001</year>
<volume>16</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>675-680</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dibart]]></surname>
<given-names><![CDATA[S. Warbigton M]]></given-names>
</name>
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Skobe]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro evaluation of implant-abutment bacterial seal: the locking taper system]]></article-title>
<source><![CDATA[J Oral Maxillofac Implants]]></source>
<year>2005</year>
<volume>20</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>732-737</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1997</year>
<volume>8</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>290-298</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jaffin]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Berman]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The excessive loss of Branemark fixture in type IV bone: a 5 year analysis]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>1991</year>
<volume>62</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>2-4</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brunski]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biocompatibility, biofunctionality and biomechanics of dental implants]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Block]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Kent]]></surname>
<given-names><![CDATA[JN]]></given-names>
</name>
<name>
<surname><![CDATA[Guerra]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Fletcher]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Implants in dentistry]]></source>
<year>1997</year>
<page-range>63-71</page-range><publisher-loc><![CDATA[Philadelphia ]]></publisher-loc>
<publisher-name><![CDATA[Saunders]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bahat]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Brånemark system implants in posterior maxilla: clinical study of 660 implants followed for 5 to 12 years]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2000</year>
<volume>15</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>646-653</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Leonardis]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Osseointegration of rough acid-etched Titanium implants: 5 year follow up of 100 minimatic implants]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1999</year>
<volume>14</volume>
<numero>13</numero>
<issue>13</issue>
<page-range>384-391</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gentile]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Chuang]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Dodson]]></surname>
<given-names><![CDATA[TB.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survival estimates and risk factor for failure with 6 x 5. 7 mm implants]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2005</year>
<volume>20</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>930-937</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fugazzotto]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Shorter implants in clinical practice: rationale and treatment results]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2008</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>487-496</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Leonard]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Coelho]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Polyzois]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Stassen]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Claffey]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A study of the bone healing kinetics of plateau versus screw root design titanium dental implants]]></article-title>
<source><![CDATA[Clin Oral Impl Res]]></source>
<year>2009</year>
<volume>20</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>232-239</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Misch]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Perel]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[HL]]></given-names>
</name>
<name>
<surname><![CDATA[Sammartino]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Galindo-]]></surname>
<given-names><![CDATA[Moreno P]]></given-names>
</name>
<name>
<surname><![CDATA[Trisi]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implant success, survival, and failure: the international congress of oral implantologists (ICOI) Pisa, Consensus conference]]></article-title>
<source><![CDATA[Implant Dent]]></source>
<year>2008</year>
<volume>17</volume>
<page-range>5-15</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Adell]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Erickson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Lekholm]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Brånemark]]></surname>
<given-names><![CDATA[PI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A longterm follow-up study of osseointegrated implants in the treatment of totally edentulous jaws]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1990</year>
<volume>5</volume>
<page-range>347-359</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mericske-Stern]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bernard]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Behneke]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hirt]]></surname>
<given-names><![CDATA[HP]]></given-names>
</name>
<name>
<surname><![CDATA[Belser]]></surname>
<given-names><![CDATA[UC,]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-term evaluation of non submerged ITI implants Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants]]></article-title>
<source><![CDATA[Clin Oral Implant Res]]></source>
<year>1997</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>161-172</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arismendi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Agudelo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ospina]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Implantes de superfície lisa o rugosa: una decisión clínica]]></article-title>
<source><![CDATA[Rev Int Protes Estomatol]]></source>
<year>2004</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>9-15</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sykaras]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Lacopino]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Marker]]></surname>
<given-names><![CDATA[VA]]></given-names>
</name>
<name>
<surname><![CDATA[Triplett]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[Woody]]></surname>
<given-names><![CDATA[RD. Implant materials]]></given-names>
</name>
<name>
<surname><![CDATA[designs]]></surname>
<given-names><![CDATA[and]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A literature review]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2000</year>
<volume>15</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>675-690</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanisms of Endosseous integration]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>1998</year>
<volume>11</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>391-401</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kanagaraja]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wenneberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Eriksson,]]></surname>
<given-names><![CDATA[Nygren]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cellular reactions and bone apposition to titanium surface with different surface roughness and oxide thickness cleaned by oxidation]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2001</year>
<volume>22</volume>
<numero>13</numero>
<issue>13</issue>
<page-range>1809-1818</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abrahamsson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Zitzmann]]></surname>
<given-names><![CDATA[NU]]></given-names>
</name>
<name>
<surname><![CDATA[Berglundh]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Wennerberg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lindhe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bone and soft tissue integration to titanium implants with different surface topography: an experimental study in the dog]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2001</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>323-332</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muftu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Chapman]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Replacing posterior teeth with freestanding implants: four- year prosthodontic results of a prospective study]]></article-title>
<source><![CDATA[J Am Dent Assoc]]></source>
<year>1998</year>
<volume>129</volume>
<page-range>1097-1102</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Das]]></surname>
<given-names><![CDATA[Neves FD]]></given-names>
</name>
<name>
<surname><![CDATA[Fones]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bernardes]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
<name>
<surname><![CDATA[do]]></surname>
<given-names><![CDATA[Prado CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Neto]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Short Implants-an analysis of longitudinal studies]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2006</year>
<volume>21</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>86-93</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tawil]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Younan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical Evaluation of Short, machinedsurface implants followed for 12 to 92 months]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2003</year>
<volume>18</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>894-901</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Romeo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ghisolfi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rozza]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Chiapasco]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lops]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Short (8-mm) dental implants in the rehabilitation of partial and complete edentulism: a 3-to 14-year longitudinal study]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2006</year>
<volume>19</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>586-592</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
