<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0121-5256</journal-id>
<journal-title><![CDATA[Revista Med]]></journal-title>
<abbrev-journal-title><![CDATA[rev.fac.med]]></abbrev-journal-title>
<issn>0121-5256</issn>
<publisher>
<publisher-name><![CDATA[Universidad Militar Nueva Granada. Facultad de Medicina]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0121-52562015000200007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[PREDICCIONES DE LA ENTROPÍA PROPORCIONAL EN LA DINÁMICA CARDÍACA]]></article-title>
<article-title xml:lang="en"><![CDATA[PREDICTIONS OF PROPORTIONAL ENTROPY IN CARDIAC DYNAMICS]]></article-title>
<article-title xml:lang="pt"><![CDATA[PREVISÕES DE ENTROPIA PROPORCIONAL NA DINÂMICA CARDÍACA]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[RODRÍGUEZ]]></surname>
<given-names><![CDATA[JAVIER]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[PRIETO]]></surname>
<given-names><![CDATA[SIGNED]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[CORREA]]></surname>
<given-names><![CDATA[CATALINA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[SORACIPA]]></surname>
<given-names><![CDATA[YOLANDA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[MORA]]></surname>
<given-names><![CDATA[JESSICA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[BERNAL]]></surname>
<given-names><![CDATA[PEDRO]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[FORERO]]></surname>
<given-names><![CDATA[MARÍA]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[ACUÑA]]></surname>
<given-names><![CDATA[CAMILO]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Militar Nueva Granada Grupo Insight Centro de Investigaciones Clínica del Country]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>07</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>07</month>
<year>2015</year>
</pub-date>
<volume>23</volume>
<numero>2</numero>
<fpage>60</fpage>
<lpage>70</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0121-52562015000200007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0121-52562015000200007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0121-52562015000200007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Antecedentes: A partir de la teoría de sistemas dinámicos se desarrolló una metodología que permite diferenciar dinámicas cardíacas normales, en distintos niveles de enfermedad y en evolución entre estos estados. Esto se hizo cuantificando en el espacio de fases, mediante la entropía y sus proporciones, la probabilidad de parejas ordenadas de frecuencias cardiacas. Objetivo: Aplicar clínicamente la metodología desarrollada a 400 dinámicas cardíacas para establecer su efectividad comparándola con el diagnóstico clínico convencional. Método: Se tomaron Holters de 400 individuos; 50 diagnosticados como normales y 350 con diferentes patologías. Para cada uno se construyó un atractor en el mapa de retardo y se evaluó, mediante la entropía y sus proporciones, la probabilidad de ocupación de pares ordenados de frecuencias cardíacas durante 18 horas. Se compararon las medidas obtenidas con los valores de normalidad y enfermedad establecidos previamente para obtener el diagnóstico de cada Holter. Las conclusiones del Holter y los antecedentes clínicos sólo fueron desenmascarados luego de haber aplicado la metodología físico-matemática para calcular sensibilidad, especificidad y coeficiente Kappa respecto al Gold-Estándar. Resultados: con las proporciones de la entropía de los atractores se diferenciaron dinámicas cardíacas agudas, crónicas, normales, y evolución normalidad-enfermedad. Se confirmó la aplicabilidad clínica de la metodología predictiva desarrollada para el Holter, que mostró una sensibilidad y especificidad del 100%. La concordancia entre el Gold-Estándar y el diagnóstico físicomatemático fue 1. Conclusiones: La aplicación de la metodología permitió establecer cuantitativamente estados de normalidad y enfermedad de la dinámica cardíaca, evidenciando una auto-organización del atractor dinámico geométrico que constituye un método de ayuda diagnóstica aplicable a la clínica.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Based on dynamic systems theory, a methodology that allows to differentiate normal cardiac dynamics, different levels of abnormality and evolution between these states, was developed. This was done by quantifying the probability of ordered pairs of heart rates in the phase space, through entropy and its proportions. To apply in a clinical setting the developed methodology to 400 cardiac dynamics in order to establish its effectiveness by comparing it with the conventional diagnosis. Holters from 400 individuals were tested for a minimum of 18 hours; 50 with normal diagnosis and 350 with different pathologies. An attractor was built for each one of them in the delay map, and the occupation probability of ordered pairs of heart rates was evaluated through entropy and its proportions. Afterwards, results were compared with values of normality and disease previously established to obtain the diagnosis for each Holter. The findings of Holter and medical history were only revealed after applying the physical-mathematical methodology, in order to calculate sensitivity, specificity and Kappa coefficient regarding to the Gold-Standard. With the entropy proportions of the attractors, acute cardiac dynamics were differentiated from chronic and normal ones, as well as the evolution between normality and disease. A clinical application of the predictive methodology for Holter was developed. Sensitivity and specificity were both 100% and the correlation between the Gold-Standard and the physical-mathematical diagnosis was 1. The application of the methodology allowed establishing quantitatively states of normality and disease of the cardiac dynamic, showing a self-organization of the geometrical dynamic attractor.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Antecedentes: A partir da teoria de sistemas dinâmicos se desarrolho uma metodologia que permite diferenciar dinâmicas cardíacas normais, em distintos niveles de doença e na evolução entre estes estados, o qual foi realizado quantificando no espaço de fases a probabilidade de pares ordenados de frequências cardíacas, através da entropia e as suas proporções. Objetivo: Aplicar clinicamente a metodologia desenvolvida a 400 dinâmicas cardíacas para estabelecer sua eficácia comparada com o diagnóstico clínico convencional. Método: Se tiraram Holters de 400 pessoas, 50 deles foram diagnosticados como normais e 350 têm diferentes patologias. Um atractor no mapa de retardos foi construído para cada um deles e, através da entropia e as suas proporções, a probabilidades de ocupação de pares ordenados de frequências cardíacas durante 18 horas foi avaliada. Além disso, as medidas obtidas foram comparadas com os valores de normalidade e doenças estabelecidas previamente para obter o diagnostico de cada Holter. As conclusões do Holter e os antecedentes clínicos somente foram descobertos logo de aplicar a metodologia físico-matemática para calcular a sensibilidade, especificidade y coeficiente Kappa acerca do Padrão-Ouro (Gold-Standard). Resultados: As dinâmicas cardíacas agudas, crônicas, normais y a evolução da normalidade e as doenças foram diferenciadas pelas proporções da entropia dos atractores. Confirmou-se a aplicabilidade clínica da metodologia preditiva desenvolvida para o Holter, a qual demonstrou uma sensibilidade e especificidade de 100%. O acordo entre o Padrão-Ouro (Gold-Standard) e o diagnóstico físico-matemático foi 1. Conclusões: A aplicabilidade da metodologia permitiu estabelecer quantitativamente estado de normalidade e doenças da dinâmica cardíaca, mostrando uma auto-organização do atrator dinâmico geométrico que constitui um método de ajuda diagnostica aplicável à clínica.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[diagnóstico]]></kwd>
<kwd lng="es"><![CDATA[enfermedades cardiovasculares]]></kwd>
<kwd lng="es"><![CDATA[adulto]]></kwd>
<kwd lng="es"><![CDATA[frecuencia cardíaca]]></kwd>
<kwd lng="es"><![CDATA[dinámicas no Lineales]]></kwd>
<kwd lng="en"><![CDATA[diagnosis]]></kwd>
<kwd lng="en"><![CDATA[cardiovascular diseases]]></kwd>
<kwd lng="en"><![CDATA[adult]]></kwd>
<kwd lng="en"><![CDATA[heart rate]]></kwd>
<kwd lng="en"><![CDATA[nonlinear dynamics]]></kwd>
<kwd lng="pt"><![CDATA[Diagnóstico]]></kwd>
<kwd lng="pt"><![CDATA[doenças cardiovasculares]]></kwd>
<kwd lng="pt"><![CDATA[adultos]]></kwd>
<kwd lng="pt"><![CDATA[frequências cardíacas]]></kwd>
<kwd lng="pt"><![CDATA[dinâmicas não lineares]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="verdana" size="2"><b>ART&Iacute;CULO ORIGINAL</b></font></p>     <p align="center"><font face="verdana" size="4"><b>PREDICCIONES DE LA ENTROP&Iacute;A PROPORCIONAL EN LA DIN&Aacute;MICA CARD&Iacute;ACA</b></font></p>     <p align="center"><font face="verdana" size="3"><b>PREDICTIONS OF PROPORTIONAL ENTROPY IN CARDIAC DYNAMICS</b></font></p>     <p align="center"><font face="verdana" size="3"><b>PREVIS&Otilde;ES DE ENTROPIA PROPORCIONAL NA DIN&Acirc;MICA CARD&Iacute;ACA</b></font></p> <font size="2" face="verdana">     <p align="center">JAVIER RODR&Iacute;GUEZ<b><sup>1*</sup></b>, SIGNED PRIETO<sup><b>2</b></sup>, CATALINA CORREA<b><sup>3</sup></b>, YOLANDA SORACIPA<b><sup>4</sup></b>, JESSICA MORA<b><sup>5</sup></b>, PEDRO BERNAL<b><sup>6</sup></b>, MARÍA FORERO<b><sup>7</sup></b>, CAMILO ACUÑA<b><sup>8</sup></b>.</p>     <p><sup><b><i>1</i></b></sup><i> MD. Director del Grupo Insight. Director de la L&iacute;nea de Profundizaci&oacute;n e Internado Especial F&iacute;sica y Matem&aacute;ticas Aplicadas a la Medicina, Universidad Militar Nueva Granada. Centro de Investigaciones Cl&iacute;nica del Country. Bogot&aacute;, Colombia.     <br>  <sup><b>2</b></sup> Investigadora Grupo Insight - Universidad Militar Nueva Granada. Centro de Investigaciones Cl&iacute;nica del Country. Bogot&aacute;, Colombia.    <br>  <sup><b>3</b></sup> Psic. Investigadora Grupo Insight. Docente l&iacute;nea de Profundizaci&oacute;n e Internado Especial: F&iacute;sica y Matem&aacute;ticas Aplicadas a la Medicina, Universidad Militar Nueva Granada. Centro de Investigaciones Cl&iacute;nica del Country. Bogot&aacute;, Colombia.     <br>  <sup><b>4</b></sup> Lic Fis. Investigadora Grupo Insight - Universidad Militar Nueva Granada. Centro de Investigaciones Cl&iacute;nica del Country. Bogot&aacute;, Colombia.    <br>  <sup><b>5</b></sup> Internado Especial: F&iacute;sica y Matem&aacute;ticas Aplicadas a la Medicina, Universidad Militar Nueva Granada. Bogot&aacute;, Colombia.    ]]></body>
<body><![CDATA[<br>  <sup><b>6</b></sup> Ing. Sistemas. Bogot&aacute;, Colombia.    <br>  <sup><b>7</b></sup> MD. Investigadora Grupo Insight. Bogot&aacute;, Colombia.    <br> 	<sup><b>8</b></sup> F&iacute;s. Universidad de los Andes. Investigador Grupo Insight. Bogot&aacute;, Colombia.</i></p>     <p><i><b><sup><b>*</b></sup>Correspondencia:</b> Javier Rodr&iacute;guez. E-mail: <a href="mailto:grupoinsight2025@yahoo.es">grupoinsight2025@yahoo.es</a>. </i></p>     <p><i><b>Recibido:</b> Enero 7 de 2015 <b>Aceptado:</b> Marzo 31 de 2015</i></p> <hr>     <p><b>Resumen</b></p>     <p><b>Antecedentes: </b>A partir de la teor&iacute;a de sistemas din&aacute;micos se desarroll&oacute; una metodolog&iacute;a que permite diferenciar din&aacute;micas card&iacute;acas normales, en distintos niveles de enfermedad y en evoluci&oacute;n entre estos estados. Esto se hizo cuantificando en el espacio de fases, mediante la entrop&iacute;a y sus proporciones, la probabilidad de parejas ordenadas de frecuencias cardiacas.</p>     <p><b> Objetivo: </b>Aplicar cl&iacute;nicamente la metodolog&iacute;a desarrollada a 400 din&aacute;micas card&iacute;acas para establecer su efectividad compar&aacute;ndola con el diagn&oacute;stico cl&iacute;nico convencional.</p>     <p><b>M&eacute;todo:</b> Se tomaron Holters de 400 individuos; 50 diagnosticados como normales y 350 con diferentes patolog&iacute;as. Para cada uno se construy&oacute; un atractor en el mapa de retardo y se evalu&oacute;, mediante la entrop&iacute;a y sus proporciones, la probabilidad de ocupaci&oacute;n de pares ordenados de frecuencias card&iacute;acas durante 18 horas. Se compararon las medidas obtenidas con los valores de normalidad y enfermedad establecidos previamente para obtener el diagn&oacute;stico de cada Holter. Las conclusiones del Holter y los antecedentes cl&iacute;nicos s&oacute;lo fueron desenmascarados luego de haber aplicado la metodolog&iacute;a f&iacute;sico-matem&aacute;tica para calcular sensibilidad, especificidad y coeficiente Kappa respecto al Gold-Est&aacute;ndar.</p>     <p><b>Resultados:</b> con las proporciones de la entrop&iacute;a de los atractores se diferenciaron din&aacute;micas card&iacute;acas agudas, cr&oacute;nicas, normales, y evoluci&oacute;n normalidad-enfermedad. Se confirm&oacute; la aplicabilidad cl&iacute;nica de la metodolog&iacute;a predictiva desarrollada para el Holter, que mostr&oacute; una sensibilidad y especificidad del 100%. La concordancia entre el Gold-Est&aacute;ndar y el diagn&oacute;stico f&iacute;sicomatem&aacute;tico fue 1.</p>     ]]></body>
<body><![CDATA[<p><b>Conclusiones: </b>La aplicaci&oacute;n de la metodolog&iacute;a permiti&oacute; establecer cuantitativamente estados de normalidad y enfermedad de la din&aacute;mica card&iacute;aca, evidenciando una auto-organizaci&oacute;n del atractor din&aacute;mico geom&eacute;trico que constituye un m&eacute;todo de ayuda diagn&oacute;stica aplicable a la cl&iacute;nica.</p>     <p><b>Palabras Clave: </b>diagn&oacute;stico, enfermedades cardiovasculares, adulto, frecuencia card&iacute;aca, din&aacute;micas no Lineales.</p> <hr>     <p><b>Abstract</b></p>     <p>Based on dynamic systems theory, a methodology that allows to differentiate normal cardiac dynamics, different levels of abnormality and evolution between these states, was developed. This was done by quantifying the probability of ordered pairs of heart rates in the phase space, through entropy and its proportions. To apply in a clinical setting the developed methodology to 400 cardiac dynamics in order to establish its effectiveness by comparing it with the conventional diagnosis. Holters from 400 individuals were tested for a minimum of 18 hours; 50 with normal diagnosis and 350 with different pathologies. An attractor was built for each one of them in the delay map, and the occupation probability of ordered pairs of heart rates was evaluated through entropy and its proportions. Afterwards, results were compared with values of normality and disease previously established to obtain the diagnosis for each Holter. The findings of Holter and medical history were only revealed after applying the physical-mathematical methodology, in order to calculate sensitivity, specificity and Kappa coefficient regarding to the Gold-Standard. With the entropy proportions of the attractors, acute cardiac dynamics were differentiated from chronic and normal ones, as well as the evolution between normality and disease. A clinical application of the predictive methodology for Holter was developed. Sensitivity and specificity were both 100% and the correlation between the Gold-Standard and the physical-mathematical diagnosis was 1. The application of the methodology allowed establishing quantitatively states of normality and disease of the cardiac dynamic, showing a self-organization of the geometrical dynamic attractor.</p>     <p><b>Keywords: </b>diagnosis, cardiovascular diseases, adult, heart rate, nonlinear dynamics.</p> <hr>     <p><b>Resumo</b></p>     <p><b>Antecedentes: </b>A partir da teoria de sistemas din&acirc;micos se desarrolho uma metodologia que permite diferenciar din&acirc;micas card&iacute;acas normais, em distintos niveles de doen&ccedil;a e na evolu&ccedil;&atilde;o entre estes estados, o qual foi realizado quantificando no espa&ccedil;o de fases a probabilidade de pares ordenados de frequ&ecirc;ncias card&iacute;acas, atrav&eacute;s da entropia e as suas propor&ccedil;&otilde;es.</p>     <p><b>Objetivo: </b>Aplicar clinicamente a metodologia desenvolvida a 400 din&acirc;micas card&iacute;acas para estabelecer sua efic&aacute;cia comparada com o diagn&oacute;stico cl&iacute;nico convencional.</p>     <p><b>M&eacute;todo: </b>Se tiraram Holters de 400 pessoas, 50 deles foram diagnosticados como normais e 350 t&ecirc;m diferentes patologias. Um atractor no mapa de retardos foi constru&iacute;do para cada um deles e, atrav&eacute;s da entropia e as suas propor&ccedil;&otilde;es, a probabilidades de ocupa&ccedil;&atilde;o de pares ordenados de frequ&ecirc;ncias card&iacute;acas durante 18 horas foi avaliada. Al&eacute;m disso, as medidas obtidas foram comparadas com os valores de normalidade e doen&ccedil;as estabelecidas previamente para obter o diagnostico de cada Holter. As conclus&otilde;es do Holter e os antecedentes cl&iacute;nicos somente foram descobertos logo de aplicar a metodologia f&iacute;sico-matem&aacute;tica para calcular a sensibilidade, especificidade y coeficiente Kappa acerca do Padr&atilde;o-Ouro (Gold-Standard).</p>     <p><b>Resultados: </b>As din&acirc;micas card&iacute;acas agudas, cr&ocirc;nicas, normais y a evolu&ccedil;&atilde;o da normalidade e as doen&ccedil;as foram diferenciadas pelas propor&ccedil;&otilde;es da entropia dos atractores. Confirmou-se a aplicabilidade cl&iacute;nica da metodologia preditiva desenvolvida para o Holter, a qual demonstrou uma sensibilidade e especificidade de 100%. O acordo entre o Padr&atilde;o-Ouro (Gold-Standard) e o diagn&oacute;stico f&iacute;sico-matem&aacute;tico foi 1.</p>     ]]></body>
<body><![CDATA[<p><b>Conclus&otilde;es: </b>A aplicabilidade da metodologia permitiu estabelecer quantitativamente estado de normalidade e doen&ccedil;as da din&acirc;mica card&iacute;aca, mostrando uma auto-organiza&ccedil;&atilde;o do atrator din&acirc;mico geom&eacute;trico que constitui um m&eacute;todo de ajuda diagnostica aplic&aacute;vel &agrave; cl&iacute;nica.</p>     <p><b>Palavras-chave: </b>Diagn&oacute;stico, doen&ccedil;as cardiovasculares, adultos, frequ&ecirc;ncias card&iacute;acas, din&acirc;micas n&atilde;o lineares.</p> <hr>     <p><b>Introducci&oacute;n</b></p>     <p>La principal causa de muerte en el mundo son las enfermedades cardiovasculares, siendo 30% la tasa de mortalidad por esta causa (1). El Departamento Administrativo Nacional de Estad&iacute;stica DANE report&oacute; para el a&ntilde;o 2009 un total de 43.205 casos de muerte por dos enfermedades card&iacute;acas que se encuentran entre las cinco principales causas de mortalidad en Colombia (2), por lo que es necesario el desarrollo de metodolog&iacute;as efectivas de predicci&oacute;n de la din&aacute;mica card&iacute;aca.</p>     <p>En la teor&iacute;a de los sistemas din&aacute;micos se pueden observar tres diferentes clases de atractores: el punto, el ciclo y el ca&oacute;tico (3): los dos primeros corresponden a din&aacute;micas predecibles y el &uacute;ltimo se relaciona con una din&aacute;mica impredecible. Estos atractores presentan una forma irregular, denomin&aacute;ndose fractales, los cuales a su vez se pueden dividir en tres clases: abstractos (4,5), salvajes (5), y estad&iacute;sticos (6,7). Para caracterizar la irregularidad de los atractores ca&oacute;ticos (8) generalmente se utiliza la dimensi&oacute;n fractal. Las medidas fractales han permitido la cuantificaci&oacute;n y evaluaci&oacute;n de diferentes sistemas morfol&oacute;gicos y fisiol&oacute;gicos (9 - 11).</p>     <p>La din&aacute;mica card&iacute;aca presenta un comportamiento irregular, por lo que teor&iacute;as f&iacute;sicas y matem&aacute;ticas se han aplicado en el desarrollo de diferentes metodolog&iacute;as para la predicci&oacute;n de su comportamiento (12-23), sin embargo, la mayor&iacute;a de los trabajos realizados hasta el momento requieren estudios posteriores para su aplicaci&oacute;n cl&iacute;nica (24, 25). En contraposici&oacute;n, a partir de la teor&iacute;a de los sistemas din&aacute;micos, Rodr&iacute;guez y col., han estudiado diferentes sistemas como la din&aacute;mica card&iacute;aca fetal (26) y la de adultos (27-29), desarrollando una metodolog&iacute;a de aplicaci&oacute;n cl&iacute;nica para el Holter a partir de la evaluaci&oacute;n de la entrop&iacute;a de la probabilidad de ocupaci&oacute;n de parejas ordenadas de frecuencias cardiacas en el espacio de fases. Esta metodolog&iacute;a ha permitido diferenciar din&aacute;micas agudas, cr&oacute;nicas y normales (29), y ha mostrado ser &uacute;til en la predicci&oacute;n de la evoluci&oacute;n de la din&aacute;mica card&iacute;aca en la unidad de cuidados coronarios (30).</p>     <p>La experiencia cl&iacute;nica ha mostrado que el Holter es una de las herramientas m&aacute;s efectivas en el diagn&oacute;stico y valoraci&oacute;n de arritmias card&iacute;acas sintom&aacute;ticas y asintom&aacute;ticas, en la evaluaci&oacute;n del riesgo de varias poblaciones cardiacas y en la valoraci&oacute;n de la respuesta al tratamiento. El Holter es una prueba de electrocardiograf&iacute;a ambulatoria, de tipo no invasivo, que eval&uacute;a 2 o 3 canales electrocardiogr&aacute;ficos durante un per&iacute;odo de 24 a 48 horas, permitiendo determinar cambios din&aacute;micos de los fen&oacute;menos el&eacute;ctricos que son de corta duraci&oacute;n y transitorios (31).</p>     <p> La teor&iacute;a de la probabilidad cuantifica la ocurrencia futura de los posibles eventos de un experimento, para esto se define el espacio muestral que contiene a todos los eventos (32,33). La termodin&aacute;mica y la mec&aacute;nica estad&iacute;stica estudian fen&oacute;menos en los que est&aacute;n involucrados un 23 n&uacute;mero de cuerpos del orden de 10<sup>23</sup> , constituyendo la primera de las tres revoluciones cient&iacute;ficas de la f&iacute;sica moderna, junto con la mec&aacute;nica cu&aacute;ntica y los sistemas din&aacute;micos (34). Para la descripci&oacute;n de estos fen&oacute;menos se utiliza el concepto de entrop&iacute;a, el cual fue enunciado inicialmente por Carnot y ha sido reinterpretado en la teor&iacute;a cin&eacute;tica de los gases, la mec&aacute;nica estad&iacute;stica y la teor&iacute;a de la informaci&oacute;n (35,36).</p>     <p> El prop&oacute;sito de la presente investigaci&oacute;n es la aplicaci&oacute;n de la metodolog&iacute;a desarrollada previamente (29) a Holters con diferentes tipos de patolog&iacute;a, para comprobar la capacidad predictiva de la metodolog&iacute;a respecto al diagn&oacute;stico cl&iacute;nico convencional del Holter.</p>     <p><b>Definiciones </b></p>     ]]></body>
<body><![CDATA[<p><b>Mapa de retardo: </b>Tipo de atractor que representa la relaci&oacute;n entre un punto dado de una serie de tiempo graficado en el eje x, y otro punto en la serie de tiempo graficada en el eje y (37). En este caso la serie de tiempo son las frecuencias cardiacas consecutivas en el tiempo.</p>     <p><b>Par ordenado de frecuencias cardiacas: </b>Pareja de frecuencias cardiacas consecutivas del mapa de retardo representadas como (X, Y), se ubicar&aacute;n en el rango de a cinco correspondiente de acuerdo a sus coordenadas.</p>     <p><b>Probabilidad de pares ordenados consecutivos en rangos de 5: </b>Cociente entre el n&uacute;mero de pares ordenados que ocupen un rango y el total de pares ordenados de todo el examen (33).</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec01.jpg"></p>     <p>Donde: X y Y son m&uacute;ltiplos de 5.</p>     <p>Entrop&iacute;a del atractor: La entrop&iacute;a (S) de la ocupaci&oacute;n de un atractor en el espacio de fases se define como la suma de los productos de las probabilidades de los rangos (X, Y) (ver definici&oacute;n anterior), con sus correspondientes logaritmos:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec02.jpg"></p>     <p>Donde: es la probabilidad para el rango (X, Y), con X y Y siendo m&uacute;ltiplos de 5, k la constante de Boltzmann (34,36) y n es el n&uacute;mero total de frecuencias del trazado.</p>     <p><b>Proporci&oacute;n S/k del atractor</b>: Se obtiene al tomar la ecuaci&oacute;n anterior y dividirla por la constante de Boltzmann (<i>k</i>):</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec03.jpg"></p>     ]]></body>
<body><![CDATA[<p>Ahora, si agrupamos t&eacute;rminos y tomamos los rangos (X,Y) cuya frecuencia de aparici&oacute;n sea de unidades, decenas, centenas y miles, llamamos:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec03a.jpg"></p>     <p>Donde: (a,b) son los rangos con una frecuencia de aparici&oacute;n de unidades con a y b siendo m&uacute;ltiplos de 5.</p>     <p>De igual manera se definen para:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec03b.jpg"></p>     <p>As&iacute; pues la ecuaci&oacute;n 2 tomar&aacute; la forma:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec04.jpg"></p>     <p><b>Proporciones de la entrop&iacute;a:</b> Proporciones entre las partes y la totalidad de la ecuaci&oacute;n 4, as&iacute; pues se definen como:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec05.jpg"></p>     <p><b>Regiones del atractor:</b> Se definieron tres regiones para el atractor (29).</p>     ]]></body>
<body><![CDATA[<p>Regi&oacute;n 1: Comprende todos los rangos de la frecuencia card&iacute;aca comunes a Holter normales.</p>     <p>Regi&oacute;n 2: Comprende la totalidad de los rangos ocupados por Holter normales, excluyendo los de la regi&oacute;n 1.</p>     <p>Regi&oacute;n 3: La regi&oacute;n restante total del mapa de retardo, es decir, los rangos de la frecuencia card&iacute;aca que no son ocupados por los prototipos normales.</p>     <p><b>Materiales y m&eacute;todos</b></p>     <p> Se analizaron 400 Holters evaluados desde los par&aacute;metros convencionales por un cardi&oacute;logo experto, tomados de investigaciones previas realizadas por el Grupo Insight; 350 de &eacute;stos fueron diagnosticados con alguna patolog&iacute;a (<a href="#tab1">Tabla 1</a>), y 50 fueron considerados normales.</p>     <p align="center"><a name= "tab1"><img src="img/revistas/med/v23n2/v23n2a07t01.jpg"></a></center></p>     <p>La informaci&oacute;n cl&iacute;nica y conclusiones registrados cada Holter fueron enmascarados. La &uacute;nica informaci&oacute;n no enmascarada correspondi&oacute; a los valores para cada hora de frecuencias card&iacute;acas m&iacute;nimas y m&aacute;ximas y el n&uacute;mero total de latidos, con base en los cuales se realiz&oacute; una simulaci&oacute;n de la totalidad de la din&aacute;mica para la obtenci&oacute;n del diagn&oacute;stico f&iacute;sico-matem&aacute;tico. Luego se construy&oacute; un atractor en el mapa de retardo de acuerdo con la metodolog&iacute;a desarrollada previamente para Holters de adultos (29), donde se grafic&oacute; la frecuencia de aparici&oacute;n de pares ordenados de frecuencias. Posteriormente se evalu&oacute; para cada examen, en cada una de las regiones (ver definiciones), la probabilidad de ocupaci&oacute;n respecto a la totalidad. Dicha probabilidad se cuantific&oacute; para cada uno de los rangos de a cinco en el espacio de fases (Ecuaci&oacute;n 1), donde cada pareja de frecuencias cardiacas se consider&oacute; como un evento, y luego se evalu&oacute; la entrop&iacute;a de cada atractor (Ecuaci&oacute;n 2).</p>     <p>Por &uacute;ltimo, se calcul&oacute; la relaci&oacute;n S/k (ver definiciones, ecuaci&oacute;n 3) y se agruparon los sumandos que corresponden a probabilidades asociadas a frecuencias de ocupaci&oacute;n de unidades (de 1 a 9), decenas (de 10 a 99), centenas (de 100 a 999) y miles (de 1000 a 9999) (Ecuaci&oacute;n 4). Finalmente se evaluaron las proporciones de la entrop&iacute;a (ver definiciones, ecuaci&oacute;n 5) para cada regi&oacute;n determinada.</p>     <p> Aplicando la metodolog&iacute;a diagn&oacute;stica desarrollada, se evalu&oacute; el criterio para diferenciar anormalidad y normalidad para cada Holter. Para esto se analiz&oacute; el n&uacute;mero de proporciones, en cualquiera de las tres regiones, que se encontrara fuera de los l&iacute;mites de normalidad definidos en trabajos previos (29). Se estableci&oacute; entonces que si el n&uacute;mero es dos o m&aacute;s la din&aacute;mica es anormal, de lo contrario la din&aacute;mica es normal (29).</p>     <p>Para cuantificar la evoluci&oacute;n entre normalidad y anormalidad de cada din&aacute;mica, es decir, cuantificar espec&iacute;ficamente la diferencia de la din&aacute;mica respecto a la normalidad, se realizaron restas entre los valores de las proporciones de la din&aacute;mica espec&iacute;fica y los valores de los extremos de los intervalos de normalidad. As&iacute;, si el valor era mayor a los l&iacute;mites de normalidad se le restaba el l&iacute;mite superior de normalidad, mientras que los valores inferiores al valor m&iacute;nimo de normalidad fueron restados de dicho valor l&iacute;mite. Finalmente, estas restas se sumaron de acuerdo a las frecuencias de aparici&oacute;n asociadas a las proporciones que se evaluaron, as&iacute; pues <b>M</b> agrup&oacute; las restas de las proporciones asociadas a frecuencias de aparici&oacute;n de miles, <b>C</b> a las de centenas, <b>D</b> a las de decenas y <b>U</b> a las de unidades.</p>     ]]></body>
<body><![CDATA[<p>La presente investigaci&oacute;n se encuentra clasificada en la categor&iacute;a de investigaci&oacute;n sin riesgo, seg&uacute;n el art&iacute;culo 11 de la resoluci&oacute;n 008430 de 1993, del Ministerio de Salud, debido a que la metodolog&iacute;a aplicada consiste en hacer c&aacute;lculos f&iacute;sicos sobre resultados de ex&aacute;menes no invasivos de la pr&aacute;ctica cl&iacute;nica que han sido previamente medicamente prescritos, haciendo innecesario el uso de consentimientos informados. Tambi&eacute;n se protegi&oacute; la privacidad, integridad y anonimato de los ex&aacute;menes estudiados.</p>     <p><b>Metodolog&iacute;a Estad&iacute;stica </b></p>     <p>Para el an&aacute;lisis estad&iacute;stico, el diagn&oacute;stico convencional fue desenmascarado y se tom&oacute; como Gold-Est&aacute;ndar para compararlo con la metodolog&iacute;a matem&aacute;tica. Se calcul&oacute; especificidad y sensibilidad a trav&eacute;s de una clasificaci&oacute;n binaria, donde los verdaderos positivos (VP) corresponden al n&uacute;mero de pacientes anormales de acuerdo al Gold- Est&aacute;ndar y que se encuentran dentro de los valores matem&aacute;ticos correspondientes a anormalidad, falsos positivos (FP) aquellos que matem&aacute;ticamente se comportan como estudios anormales y cuyo diagn&oacute;stico cl&iacute;nico es normal, falsos negativos (FN) los que han sido diagnosticados matem&aacute;ticamente como normales pero cuyos valores cl&iacute;nicos se corresponden con pacientes anormales, y finalmente verdaderos negativos (VN) definidos como el n&uacute;mero de registros card&iacute;acos diagnosticados cl&iacute;nicamente como normales y cuyos valores matem&aacute;ticos tambi&eacute;n se corresponden con normalidad.</p>     <p>La concordancia entre los valores f&iacute;sico-matem&aacute;ticos y el diagn&oacute;stico cl&iacute;nico convencional se calcul&oacute; con el coeficiente Kappa a trav&eacute;s de la siguiente f&oacute;rmula:</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec06.jpg"></p>     <p>Donde:</p>     <p> Co: n&uacute;mero de concordancias observadas, es decir, n&uacute;mero de pacientes con el mismo diagn&oacute;stico de acuerdo con la nueva metodolog&iacute;a propuesta y con el Gold-Est&aacute;ndar.</p>     <p> To: totalidad de observaciones, es decir, la totalidad de casos normales y con enfermedad.</p>     <p> Ca: Concordancias atribuibles al azar, que se calculan de acuerdo con la siguiente f&oacute;rmula</p>     <p><img src="img/revistas/med/v23n2/v23n2a07ec07.jpg"></p>     ]]></body>
<body><![CDATA[<p>Donde f<sub>1</sub> es el n&uacute;mero de pacientes que presentan valores matem&aacute;ticos dentro de los l&iacute;mites de normalidad, C<sub>1</sub> es el n&uacute;mero de pacientes diagnosticados cl&iacute;nicamente dentro de la normalidad, f<sub>2</sub> es el n&uacute;mero de pacientes que presentan valores matem&aacute;ticos asociados a anormalidad, C<sub>2</sub> es el n&uacute;mero de pacientes diagnosticados cl&iacute;nicamente con alguna patolog&iacute;a y T<sub>o</sub> es el n&uacute;mero total de casos normales y anormales.</p>     <p><b>Resultados</b></p>     <p> Las parejas ordenadas en rangos de a cinco para las frecuencias de los atractores cardiacos variaron entre &#91;40,40&#93; y &#91;165,165&#93;; entre &#91;55,55&#93; y &#91;165,165&#93; para las din&aacute;micas normales y para las anormales entre &#91;40,40&#93; y &#91;135,135&#93;. Se encontr&oacute; que los valores de probabilidad de las frecuencias de ocupaci&oacute;n de las parejas de la frecuencia card&iacute;aca en el espacio de fases estuvieron entre 0 y 0,152, con frecuencias de ocupaci&oacute;n entre 0 y 8314 respectivamente. Se encontr&oacute; que los valores de la entrop&iacute;a para los Holter anormales variaron entre 3,91x10<sup>-23</sup> y 6,80x10<sup>-23</sup> y, para los normales, entre 6,41x10<sup>-23</sup> y 7,24x10<sup>-23</sup> (datos no mostrados), confirmando los resultados de la metodolog&iacute;a diagn&oacute;stica desarrollada previamente, donde los valores para los casos normales deber&iacute;an ser mayores o iguales a 6,39 x10<sup>-23</sup>. De la misma forma, el m&aacute;ximo valor de entrop&iacute;a para los casos agudos fue de 4,86 x10 , confirmando que las din&aacute;micas agudas tendr&iacute;an un valor menor o igual a 5,07x10<sup>-23</sup> (29).</p>     <p>El valor de las proporciones de la entrop&iacute;a se encontr&oacute; entre 0 y 5,64 (<a href="img/revistas/med/v23n2/v23n2a07t02.jpg" target="_blank">Tabla 2</a>), y para las sumas de las restas de las proporciones que se encontraron fuera de los l&iacute;mites de la normalidad, los valores estuvieron entre 0 y 3,70 (<a href="img/revistas/med/v23n2/v23n2a07t03.jpg" target="_blank">Tabla 3</a>). Se evidenci&oacute; que por lo menos dos de las proporciones evaluadas para los atractores anormales en cualquiera de las regiones no se encuentran contenidas dentro de los l&iacute;mites de normalidad, confirmando el par&aacute;metro diagn&oacute;stico encontrado previamente. Despu&eacute;s de realizar las medidas f&iacute;sico-matem&aacute;ticas y desenmascarar las conclusiones cl&iacute;nicas de los Holter se calcularon las medidas de especificidad y sensibilidad, siendo del 100% cada una, con un coeficiente Kappa de 1, su m&aacute;ximo valor posible.</p>     <p>Al observar las conclusiones cl&iacute;nicas de los Holters se observ&oacute; que varios de ellos correspond&iacute;an a un mismo paciente en fechas diferentes. As&iacute; por ejemplo, los Holters 6, 9 y 26 (<a href="img/revistas/med/v23n2/v23n2a07t03.jpg" target="_blank">Tabla 3</a>), corresponden a un paciente que fue internado en la unidad de cuidados coronarios por presentar infarto agudo de miocardio (IAM). La din&aacute;mica del d&iacute;a en que lo internaron (Holter 6) presenta un valor de miles de 2,50, que es un valor caracter&iacute;stico de enfermedad aguda. Dos d&iacute;as despu&eacute;s (Holter 9) y luego una semana despu&eacute;s (Holter 26), se volvieron a tomar Holters, observando que los valores de miles disminuyeron para el Holter 9, siendo 0,87, y luego siguieron disminuyendo para el Holter 26, siendo de 0,75. Esto mostr&oacute; matem&aacute;ticamente que el paciente evolucionaba hacia la normalidad y que el tratamiento seguido hab&iacute;a sido exitoso (<a href="#tab4">Tabla 4</a>), lo que fue corroborado con la evoluci&oacute;n cl&iacute;nica.</p>     <p align="center"><a name= "tab4"><img src="img/revistas/med/v23n2/v23n2a07t04.jpg"></a></center></p>     <p>Otro caso que tambi&eacute;n se pudo observar fue el de un paciente que ingres&oacute; con enfermedad coronaria severa fue sometido a cateterismo card&iacute;aco y colocaci&oacute;n de Stent, los holters 18, 23 y 3 (<a href="img/revistas/med/v23n2/v23n2a07t03.jpg" target="_blank">Tabla 3</a>) corresponden a la din&aacute;mica del paciente; el primer registro (Holter 18) corresponde a la din&aacute;mica del paciente post operatorio de colocaci&oacute;n del stent y presentaba unos valores de miles de 0,93, al siguiente dia se le realiz&oacute; otro monitoreo (Holter 23) que mostr&oacute; una disminuci&oacute;n en los valores de miles 0,92, mostrando una mejor&iacute;a en el paciente, lo que se corrobor&oacute; con la historia cl&iacute;nica, en la que el paciente no reportaba ning&uacute;n dolor ni s&iacute;ntoma desfavorable, sin embargo en el tercer monitoreo (Holter 3) los valores de miles ascendieron a 1,05, mostrando un evento agudo, lo que se correlaciona con el reporte de IAM del paciente (<a href="#tab5">Tabla 5</a>).</p>     <p align="center"><a name= "tab5"><img src="img/revistas/med/v23n2/v23n2a07t05.jpg"></a></center></p>     <p><b>Discusi&oacute;n</b></p>     <p> Este es el primer trabajo en el que se confirma, en una poblaci&oacute;n de 400 Holters, la aplicaci&oacute;n cl&iacute;nica de la metodolog&iacute;a desarrollada a partir del c&aacute;lculo de las proporciones de la entrop&iacute;a y el an&aacute;lisis de aparici&oacute;n de pares ordenados din&aacute;micos de los atractores ca&oacute;ticos en el espacio de fases, confirmando su capacidad diagn&oacute;stica para establecer diferencias entre normalidad, anormalidad y evoluci&oacute;n entre &eacute;stas. Los resultados obtenidos demuestran la capacidad predictiva y diagn&oacute;stica de la teor&iacute;a desarrollada, as&iacute; como su aplicabilidad cl&iacute;nica a cada caso particular sin necesidad de los par&aacute;metros poblacionales de la epidemiolog&iacute;a. Esta metodolog&iacute;a, al basarse en el orden geom&eacute;trico y matem&aacute;tico del espacio universal de los atractores ca&oacute;ticos, desarrolla predicciones matem&aacute;ticas que no necesitan validaci&oacute;n estad&iacute;stica. El an&aacute;lisis estad&iacute;stico realizado en este art&iacute;culo se hizo como parte de los requisitos de la literatura m&eacute;dica actual.</p>     ]]></body>
<body><![CDATA[<p> La aplicaci&oacute;n de teor&iacute;as matem&aacute;ticas y f&iacute;sicas al registro Holter (12-23), en contraste con el an&aacute;lisis de la variabilidad de la frecuencia card&iacute;aca a partir de los cambios RR, ha revaluado el concepto de variabilidad como par&aacute;metro diagn&oacute;stico y predictor de la din&aacute;mica card&iacute;aca. Se ha mostrado que la din&aacute;mica card&iacute;aca presenta un comportamiento ca&oacute;tico o irregular (38), contrario a la concepci&oacute;n homeost&aacute;tica, cuyo diagn&oacute;stico de normalidad y enfermedad corresponden a regularidad e irregularidad respectivamente. Gold Berger y cols. (12) aplicando la teor&iacute;a de sistemas din&aacute;micos desarrollaron una concepci&oacute;n de salud - enfermedad aplicada a la fisiolog&iacute;a card&iacute;aca, donde la normalidad se encuentra en el rango intermedio entre la extrema irregularidad y la extrema regularidad, que corresponden al comportamiento patol&oacute;gico. Tambi&eacute;n se desarrollaron medidas predictivas de mortalidad con dimensiones fractales de la frecuencia card&iacute;aca en pacientes diagnosticados con infarto agudo de miocardio (IAM) con fracci&oacute;n de eyecci&oacute;n (FE) menor a 35%, encontrando factores predictores de muerte m&aacute;s confiables (13).</p>     <p> La aplicaci&oacute;n de m&eacute;todos de din&aacute;mica no lineal ha mostrado nuevas ideas acerca del comportamiento de la din&aacute;mica de la frecuencia card&iacute;aca, as&iacute; como tambi&eacute;n ha definido diferentes &iacute;ndices para el estudio de dicha din&aacute;mica. Sin embargo, la aplicabilidad de estas metodolog&iacute;as debe ser sometida a la realizaci&oacute;n de m&aacute;s estudios (24) que permitan aclarar qu&eacute; m&eacute;todos deben ser aplicados bajo ciertas condiciones estandarizadas (25). Tambi&eacute;n se ha discutido la capacidad de las t&eacute;cnicas convencionales de an&aacute;lisis no lineal de series de tiempo en el estudio de la din&aacute;mica card&iacute;aca, pues &eacute;stas generalmente carecen de sensibilidad y especificidad suficientes para discriminar una din&aacute;mica ca&oacute;tica del ruido aleatorio (39), as&iacute; como de m&eacute;todos basados en medidas fractales o entr&oacute;picas dado que han mostrado ser indicadores pobres de la no linealidad de la din&aacute;mica card&iacute;aca (40).</p>     <p>Esta metodolog&iacute;a est&aacute; fundamentada en teor&iacute;as f&iacute;sicas y matem&aacute;ticas, (sistemas din&aacute;micos y probabilidad) y en leyes y principios de la f&iacute;sica te&oacute;rica (probabilidad y entrop&iacute;a) lo que permite que la metodolog&iacute;a sea aplicable a cada caso particular en la pr&aacute;ctica cl&iacute;nica diaria como un m&eacute;todo de ayuda diagn&oacute;stica, de prevenci&oacute;n y de evaluaci&oacute;n de intervenciones, pues no requiere para su aplicaci&oacute;n de metodolog&iacute;as epidemiol&oacute;gicas que dependan de poblaciones. El concepto de entrop&iacute;a fue definido originalmente por Carnot (41) en la teor&iacute;a termodin&aacute;mica, luego fue generalizado en la mec&aacute;nica estad&iacute;stica (34,35), posteriormente fue reinterpretado (36-39,41, 42). En este trabajo la entrop&iacute;a es una medida del orden subyacente del atractor geom&eacute;trico que muestra la auto organizaci&oacute;n de las distribuciones de probabilidades, que permite un an&aacute;lisis te&oacute;rico de la totalidad del fen&oacute;meno.</p>     <p>Anal&oacute;gicamente los atractores num&eacute;ricos se pueden observar como ventanas temporales (43) definidos en un espacio finito y acotado que permiten establecer estados geom&eacute;tricos intr&iacute;nsecos que sustentan las diferencias num&eacute;ricas entre normalidad y anormalidad. La evoluci&oacute;n de la din&aacute;mica card&iacute;aca se obtiene con la sucesi&oacute;n de ventanas temporales como se observ&oacute; en los casos en los que diferentes Holters correspond&iacute;an a un mismo paciente pero en diferentes tiempos. En estos casos la metodolog&iacute;a mostr&oacute; la capacidad de evaluaci&oacute;n y de predicci&oacute;n de la evoluci&oacute;n del paciente, evidenciando los cambios en la din&aacute;mica en los valores num&eacute;ricos obtenidos, permitiendo que por ejemplo en el segundo caso (<a href="#tab5">tabla 5</a>) aunque el paciente no presentaba s&iacute;ntomas que mostraran que la intervenci&oacute;n no hab&iacute;a sido exitosa, las medidas matem&aacute;ticas s&iacute; lo evidenciaron notablemente con un aumento en los valores de miles, lo que se corrobor&oacute; cl&iacute;nicamente pues el paciente present&oacute; posteriormente un IAM. Este tipo de resultados en los que se ha predicho matem&aacute;ticamente la evoluci&oacute;n de un paciente tambi&eacute;n se han obtenido en otros trabajos (44), lo que sugiere que las predicciones obtenidas son de gran ayuda a nivel cl&iacute;nico para evaluar la evoluci&oacute;n en la recuperaci&oacute;n de pacientes que han sido intervenidos farmacol&oacute;gica y/o quir&uacute;rgicamente.</p>     <p> La concepci&oacute;n causal-determinista de la f&iacute;sica cl&aacute;sica fue revaluada con la aparici&oacute;n de la mec&aacute;nica estad&iacute;stica, la mec&aacute;nica cu&aacute;ntica y la teor&iacute;a del caos, en las que no necesariamente existe una relaci&oacute;n causal entre los fen&oacute;menos, y no se puede establecer en forma determinista la evoluci&oacute;n de los mismos. Sin embargo, la indeterminaci&oacute;n o aleatoriedad, as&iacute; como la determinaci&oacute;n, son necesarias para la f&iacute;sica (45). En este trabajo se observa la din&aacute;mica card&iacute;aca desde leyes y teor&iacute;as de la f&iacute;sica, pero desde una posici&oacute;n determinista-indeterminista en donde se observa el atractor como un sistema de auto organizaci&oacute;n simult&aacute;nea no equiprobable de los rangos de frecuencias. As&iacute;, habr&aacute; rangos m&aacute;s probables que otros y la probabilidad estar&aacute; "cargada" en lugares particulares del atractor (46). La aplicabilidad de esta concepci&oacute;n en la caracterizaci&oacute;n de una din&aacute;mica considerada ca&oacute;tica sugiere que el orden encontrado puede sustentar un principio general para cualquier sistema din&aacute;mico ca&oacute;tico.</p>     <p><b> Agradecimientos </b></p>     <p>A la Universidad Militar Nueva Granada, especialmente a Vicerrector&iacute;a de Investigaciones, al Fondo de Investigaciones y a la Facultad de Medicina por apoyar nuestros trabajos. Agradecemos especialmente a las Doctoras Jacqueline Blanco, Vicerrectora de Investigaciones, Martha Baham&oacute;n, Vicerrectora Acad&eacute;mica, Esperanza Fajardo, Directora de Investigaciones de la Facultad de Medicina, y a los Doctores Juan Miguel Estrada, Decano de la Facultad de Medicina, Alejandro Castro, Jefe de la Divisi&oacute;n de Investigaci&oacute;n Cient&iacute;fica, y a Henry Acu&ntilde;a, por su apoyo a nuestras investigaciones.</p>     <p><b>Conflictos de inter&eacute;s </b></p>     <p>Los autores declaran no tener de manera directa o indirecta, ning&uacute;n tipo de conflicto de intereses financieros, acad&eacute;micos o laborales que puedan poner en peligro la validez de este estudio.</p>     <p><b>Financiaci&oacute;n </b></p>     ]]></body>
<body><![CDATA[<p>Producto derivado del proyecto MED-1078 financiado por el Fondo de Investigaciones Universidad Militar Nueva Granada.</p>     <p><b>Dedicatoria </b></p>     <p>A nuestros hijos.</p> <HR>     <p><b>Referencias</b></p>     <!-- ref --><p>1. OMS - Centro de prensa. Enfermedades Cardiovasculares. Nota descriptiva. &#91;Internet&#93; marzo de 2013. &#91;acceso abril 13 de 2013&#93;. Disponible en <a href="http://www.who.int/mediacentre/factsheets/fs317/es/index.html"target="_blank">http://www.who.int/mediacentre/factsheets/fs317/es/index.html</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608829&pid=S0121-5256201500020000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Robledo R, Escobar FA. Las enfermedades cr&oacute;nicas no transmisibles en Colombia. Bolet&iacute;n del Observatorio en Salud. 2010;3(4):1-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608830&pid=S0121-5256201500020000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>3. Devaney R. A first course in chaotic dynamical systems theory and experiments. Reading Mass.: Addison- Wesley; 1992.p.1- 48.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608832&pid=S0121-5256201500020000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>4. Mandelbrot B. The fractal geometry of nature. Tusquets Eds S.A. Barcelona; 2000. p. 341-348.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608834&pid=S0121-5256201500020000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>5. Peitgen H, Jurgens H, Saupe D. Chaos and Fractals: New Frontiers of Science. New York: Springer-Verlag; 1992.p.67- 766.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608836&pid=S0121-5256201500020000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>6. Rodr&iacute;guez J. Comportamiento fractal del repertorio T espec&iacute;fico contra el al&eacute;rgeno Poa P9. Rev Fac Med Univ Nac Colomb. 2005;53(2):72-78.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608838&pid=S0121-5256201500020000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>7. Burgos J. Fractal representation of the immune B cell repertoire. Bio Systems. 1996; 39:19 - 24.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608840&pid=S0121-5256201500020000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>8. Peitgen, H. Length area and dimension. Measuring complexity and scalling properties. Chaos and Fractals: New Frontiers of Science. New York: Springer-Verlag; 1992.p.183-228.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608842&pid=S0121-5256201500020000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>9. Bassingthwaighte JB, Liebovitch LS, West BJ. Fractal Physiology. Oxford Univ. Press.N.Y.; 1994.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608844&pid=S0121-5256201500020000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>10. Goldberger A, West BJ. Fractals in physiology and medicine. Yale Journal of Biology. 1987; 60:421-435.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608846&pid=S0121-5256201500020000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>11. West BJ. Fractal Physiology and Chaos Medicine. London. World Scientific Publishing, Co., 1990.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608848&pid=S0121-5256201500020000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>12. Goldberger A, Amaral L, Hausdorff J, Ivanov P, Peng C, Stanley H. Fractal dynamics in physiology: alterations with disease and aging. Proc Natl Acad Sci USA. 2002;99(suppl1): 2466-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608850&pid=S0121-5256201500020000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>13. Huikuri HV, M&auml;kikallio T, Peng CK, Goldberger A, Hintze U, Moller M. Fractal correlation properties of R-R interval dynamics and mortality in patients with depressed left ventricular function after and acute myocardial infarction. Circulation. 2000;101:47-53.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608852&pid=S0121-5256201500020000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>14. Richman JS, Moorman JR. Physiological time-series analysis using approximate entropy and sample entropy. Am J Physiol Heart Circ Physiol 2000;278:H2039-H2049.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608854&pid=S0121-5256201500020000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>15. Peng CK, Havlin S, Stanley HE, Goldberger AL. Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos 1995;5: 82-87.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608856&pid=S0121-5256201500020000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>16. M&auml;kikallio TH, Huikuri HV, Hintze U, Videbaek J, Mitrani RD, Castellanos A, et al. Fractal analysis and time and frequencydomain measures of heart rate variability as predictors of mortality in patients with heart failure. Am J Cardiol. 2001;87(2):178-182.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608858&pid=S0121-5256201500020000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>17. Porta A, Guzzetti S, Montano N, Furlan R, Pagani M, Malliani A, Cerutti S. Entropy, entropy rate and pattern classification as tools to typify complexity in short heart period variability series. IEEE Trans. Biomed Eng. 2001;48:1282-1291.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608860&pid=S0121-5256201500020000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>18. Guzzetti S, Borroni E, Garbelli PE, Ceriani E, Della Bella P, Montano N, et al. Symbolic dynamics of heart rate variability: a probe to investigate cardiac autonomic modulation. Circulation. 2005;112:465-470.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608862&pid=S0121-5256201500020000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>19. Maestri R, Pinna GD, Accardo A, Allegrini P, Balocchi R, D'Addio G, et al. Nonlinear indices of heart rate variability in chronic heart failure patients: redundancy and comparative clinical value. J. Cardiovasc. Electrophysiol. 2007;18:425-433.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608864&pid=S0121-5256201500020000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>20. Costa M, Goldberger AL, Peng CK. Multiscale entropy analysis of biological signals. Phys Rev E 2005;71(Pt 1):021 906.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608866&pid=S0121-5256201500020000700020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>21. Baselli G, Porta A, Pagani M. Coupling arterial windkessel with peripheral vasomotion: modeling the effects on lowfrequenc y osci l lat ions. IEEE Tra ns Biomed. Eng. 2006;53:53-64.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608868&pid=S0121-5256201500020000700021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>22. Khoo MC. Modeling of autonomic control in sleep-disordered breathing. Cardiovasc. Eng. 2008;8:30-41.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608870&pid=S0121-5256201500020000700022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>23. Ivanov PC, Amaral LAN, Goldberger AL, Havlin S, Rosenblum MG, Struzik ZHE, et al. Multifractality in human heartbeat dynamics. Nature. 1999; 399:461-465.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608872&pid=S0121-5256201500020000700023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>24. Perki&ouml;m&auml;ki J, M&auml;kikallio TH, Huikuri HV. Fractal and Complexity Measures of Heart Rate Variability. Clin. Exp. Hypertens. 2005;27(2-3):149-158.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608874&pid=S0121-5256201500020000700024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>25. Voss A, Schulz S, Schroeder R, Baumert M, Caminal P. Methods derived from nonlinear dynamics for analysing heart rate variability. Phil Trans R Soc 2009; 367(1887):277-296.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608876&pid=S0121-5256201500020000700025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>26. Rodr&iacute;guez J. Dynamical systems theory and ZIPF - Mandelbrot law applied to the development of a fetal monitoring diagnostic methodology. XVIII FIGO World Congress of Gynecology And Obstetric. Kuala Lumpur, Malaysia. November 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608878&pid=S0121-5256201500020000700026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>27. Rodr&iacute;guez J, Prieto S, Avil&aacute;n N, Correa C, Bernal P, Ortiz L, et al. Nueva metodolog&iacute;a f&iacute;sica y matem&aacute;tica de evaluaci&oacute;n del Holter Rev Colomb Cardiol 2008; 15:50-54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608880&pid=S0121-5256201500020000700027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>28. Rodr&iacute;guez J, Correa C, Ortiz L, Prieto S, Bernal P, Ayala J. Evaluaci&oacute;n matem&aacute;tica de la din&aacute;mica card&iacute;aca con la teor&iacute;a de la probabilidad. Rev Mex Cardiol. 2009;20 (4):183-189.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608882&pid=S0121-5256201500020000700028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>29. Rodr&iacute;guez J. Entrop&iacute;a proporcional de los sistemas din&aacute;micos cardiacos: predicciones f&iacute;sicas y matem&aacute;ticas de la din&aacute;mica card&iacute;aca de aplicaci&oacute;n cl&iacute;nica. Rev Colomb Cardiol 2010;17:115-129.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608884&pid=S0121-5256201500020000700029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>30. Rodr&iacute;guez J, Prieto S, Bernal P, Izasa D, Salazar G, Correa C, et al. Entrop&iacute;a proporcional aplicada a la evoluci&oacute;n de la din&aacute;mica card&iacute;aca. Predicciones de aplicaci&oacute;n cl&iacute;nica. La emergencia de los enfoques de la complejidad en Am&eacute;rica Latina. Tomo I. Comunidad Editora Latinoamericana. Argentina; 2015.p.247-264.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608886&pid=S0121-5256201500020000700030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>31. Rodr&iacute;guez J, Proportional Entropy of the cardiac dynamics in CCU patients. 7th International Meeting Intensive Cardiac Care. Israel Heart Society, European Society of Cardiology, EBAC: Tel Aviv, Israel, 2011.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608888&pid=S0121-5256201500020000700031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>32. Pineda M, Matiz H, Rozo R. Enfermedad coronaria. Bogot&aacute;: Editorial Kimpres Ltda; 2002.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608890&pid=S0121-5256201500020000700032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>33. Kolmogorov AN. Foundations of the theory of probability. New York: Chelsea Publishing Company; 1950.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608892&pid=S0121-5256201500020000700033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>34. Feynman RP, Leighton RB, Sands M. Probabilidad. F&iacute;sica. Vol. 1. Primera edici&oacute;n M&eacute;xico: Addison-Wesley Iberoamericana, S. A.;1998.p.1-16.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608894&pid=S0121-5256201500020000700034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>35. Matv&eacute;ev A. F&iacute;sica molecular. Primera edici&oacute;n, MIR,Mosc&uacute;; 1987.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608896&pid=S0121-5256201500020000700035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>36. Tolman R. Principles of statistical mechanics. Primera edici&oacute;n. New York: Dover Publications; 1979.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608898&pid=S0121-5256201500020000700036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>37. Machta J. Entropy, information, and computation. Am J Phys 1999;67(12),1074-1077.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608900&pid=S0121-5256201500020000700037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>38. Denton TA, Diamond GA, Helfant RH, Khan S, Karagueuzian H. Fascinating rhythm: A primer on chaos theory and its applicat ion to cardiology. American Hear t Journal 1990:120(6);1419-40&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608902&pid=S0121-5256201500020000700038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>39. Braun C, Kowallik P, Freking A, Hadeler D, Kniffki K, Meesmann M. Demonstration of nonlinear components in heart rate variability of healthy persons Am J Physiol 1998;275:H1577-H1584.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608903&pid=S0121-5256201500020000700039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>40. Wu GQ, Arzeno NM, Shen LL, Tang DK, Zheng DA, Zhao NQ, et al. Chaotic Signatures of Heart Rate Variability and Its Power Spectrum in Health, Aging and Heart Failure. PLoS ONE 2009;4(2):e4323.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608905&pid=S0121-5256201500020000700040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>41. Cheng L, Guang H, Gou W, Chi P. Fractal, entropic and chaotic approaches to complex physiological time series analysis: A critical appraisal. 31st Annual International Conference of the IEEE EMBS Minneapolis, Minnesota, USA. 2009; 3429-3432.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608907&pid=S0121-5256201500020000700041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>42. Feynman RP, Leighton RB, Sands M.. Leyes de la Termodin&aacute;mica. F&iacute;sica. Vol. 1. Primera edici&oacute;n Addison-Wesley Iberoamericana, S.A. M&eacute;xico;1998.p.1-19.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608909&pid=S0121-5256201500020000700042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>43. Bekenstein J. La informaci&oacute;n en el Universo hologr&aacute;fico. Investigaci&oacute;n y ciencia: Octubre 2003;p.36-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608911&pid=S0121-5256201500020000700043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>44. Rodr&iacute;guez J, Prieto S, Dom&iacute;nguez D, Melo M, Mendoza F, Correa C,et al. Mathematical-physical prediction of cardiac dynamics using the proportional entropy of dynamic systems. J. Med. Med. Sci. 2013; 4(8): 370-381.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608913&pid=S0121-5256201500020000700044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p>45. Fern&aacute;ndez-Ra&ntilde;ada A. Introducci&oacute;n. Orden y Caos. Scientific American. 1990. Prensa Cient&iacute;fica S.A.; p. 4 - 8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608915&pid=S0121-5256201500020000700045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>46. Crutchfield JP. Between order and chaos. Nat Phys. 2012;8:17-24.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=3608917&pid=S0121-5256201500020000700046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p> </font>     ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<collab>OMS^dCentro de prensa</collab>
<source><![CDATA[Enfermedades Cardiovasculares. Nota descriptiva]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Robledo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Escobar]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Las enfermedades crónicas no transmisibles en Colombia]]></article-title>
<source><![CDATA[Boletín del Observatorio en Salud]]></source>
<year>2010</year>
<volume>3</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1-9</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devaney]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[A first course in chaotic dynamical systems theory and experiments]]></source>
<year>1992</year>
<page-range>1- 48</page-range><publisher-loc><![CDATA[Reading Mass ]]></publisher-loc>
<publisher-name><![CDATA[Addison- Wesley]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mandelbrot]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<source><![CDATA[The fractal geometry of nature]]></source>
<year>2000</year>
<page-range>341-348</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Tusquets Eds S.A.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peitgen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Jurgens]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Saupe]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Chaos and Fractals: New Frontiers of Science]]></source>
<year>1992</year>
<page-range>67- 766</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Springer-Verlag]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Comportamiento fractal del repertorio T específico contra el alérgeno Poa P9]]></article-title>
<source><![CDATA[Rev Fac Med Univ Nac Colomb]]></source>
<year>2005</year>
<volume>53</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>72-78</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burgos]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractal representation of the immune B cell repertoire]]></article-title>
<source><![CDATA[Bio Systems]]></source>
<year>1996</year>
<volume>39</volume>
<page-range>19 - 24</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peitgen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Length area and dimension. Measuring complexity and scalling properties. Chaos and Fractals: New Frontiers of Science]]></source>
<year>1992</year>
<page-range>183-228</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Springer-Verlag]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bassingthwaighte]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Liebovitch]]></surname>
<given-names><![CDATA[LS]]></given-names>
</name>
<name>
<surname><![CDATA[West]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<source><![CDATA[Fractal Physiology]]></source>
<year>1994</year>
<publisher-loc><![CDATA[N.Y. ]]></publisher-loc>
<publisher-name><![CDATA[Oxford Univ. Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[West]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractals in physiology and medicine]]></article-title>
<source><![CDATA[Yale Journal of Biology]]></source>
<year>1987</year>
<volume>60</volume>
<page-range>421-435</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[West]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<source><![CDATA[Fractal Physiology and Chaos Medicine]]></source>
<year>1990</year>
<publisher-loc><![CDATA[London ]]></publisher-loc>
<publisher-name><![CDATA[World Scientific Publishing, Co.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Amaral]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hausdorff]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ivanov]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Stanley]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractal dynamics in physiology: alterations with disease and aging]]></article-title>
<source><![CDATA[Proc Natl Acad Sci USA]]></source>
<year>2002</year>
<volume>99</volume>
<numero>^ssuppl1</numero>
<issue>^ssuppl1</issue>
<supplement>suppl1</supplement>
<page-range>2466-72</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Huikuri]]></surname>
<given-names><![CDATA[HV]]></given-names>
</name>
<name>
<surname><![CDATA[Mäkikallio]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[CK]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hintze]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Moller]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractal correlation properties of R-R interval dynamics and mortality in patients with depressed left ventricular function after and acute myocardial infarction]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<volume>101</volume>
<page-range>47-53</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Richman]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Moorman]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Physiological time-series analysis using approximate entropy and sample entropy]]></article-title>
<source><![CDATA[Am J Physiol Heart Circ Physiol]]></source>
<year>2000</year>
<volume>278</volume>
<page-range>H2039-H2049</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[CK]]></given-names>
</name>
<name>
<surname><![CDATA[Havlin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Stanley]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series]]></article-title>
<source><![CDATA[Chaos]]></source>
<year>1995</year>
<volume>5</volume>
<page-range>82-87</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mäkikallio]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
<name>
<surname><![CDATA[Huikuri]]></surname>
<given-names><![CDATA[HV]]></given-names>
</name>
<name>
<surname><![CDATA[Hintze]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Videbaek]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mitrani]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Castellanos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractal analysis and time and frequencydomain measures of heart rate variability as predictors of mortality in patients with heart failure]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>2001</year>
<volume>87</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>178-182</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Porta]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Guzzetti]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Montano]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Furlan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pagani]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Malliani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cerutti]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Entropy, entropy rate and pattern classification as tools to typify complexity in short heart period variability series]]></article-title>
<source><![CDATA[IEEE Trans. Biomed Eng.]]></source>
<year>2001</year>
<volume>48</volume>
<page-range>1282-1291</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guzzetti]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Borroni]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Garbelli]]></surname>
<given-names><![CDATA[PE]]></given-names>
</name>
<name>
<surname><![CDATA[Ceriani]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Della Bella]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Montano]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Symbolic dynamics of heart rate variability: a probe to investigate cardiac autonomic modulation]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2005</year>
<volume>112</volume>
<page-range>465-470</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maestri]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pinna]]></surname>
<given-names><![CDATA[GD]]></given-names>
</name>
<name>
<surname><![CDATA[Accardo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Allegrini]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Balocchi]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[D'Addio]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nonlinear indices of heart rate variability in chronic heart failure patients: redundancy and comparative clinical value]]></article-title>
<source><![CDATA[J. Cardiovasc. Electrophysiol.]]></source>
<year>2007</year>
<volume>18</volume>
<page-range>425-433</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Peng]]></surname>
<given-names><![CDATA[CK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multiscale entropy analysis of biological signals]]></article-title>
<source><![CDATA[Phys Rev E]]></source>
<year>2005</year>
<volume>71</volume>
<page-range>021 906</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baselli]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Porta]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pagani]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coupling arterial windkessel with peripheral vasomotion: modeling the effects on lowfrequenc y osci l lat ions]]></article-title>
<source><![CDATA[IEEE Tra ns Biomed. Eng.]]></source>
<year>2006</year>
<volume>53</volume>
<page-range>53-64</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khoo]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modeling of autonomic control in sleep-disordered breathing]]></article-title>
<source><![CDATA[Cardiovasc. Eng.]]></source>
<year>2008</year>
<volume>8</volume>
<page-range>30-41</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ivanov]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Amaral]]></surname>
<given-names><![CDATA[LAN]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Havlin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenblum]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[Struzik]]></surname>
<given-names><![CDATA[ZHE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multifractality in human heartbeat dynamics]]></article-title>
<source><![CDATA[Nature]]></source>
<year>1999</year>
<volume>399</volume>
<page-range>461-465</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Perkiömäki]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mäkikallio]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
<name>
<surname><![CDATA[Huikuri]]></surname>
<given-names><![CDATA[HV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractal and Complexity Measures of Heart Rate Variability]]></article-title>
<source><![CDATA[Clin. Exp. Hypertens.]]></source>
<year>2005</year>
<volume>27</volume>
<numero>2-3</numero>
<issue>2-3</issue>
<page-range>149-158</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Voss]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Schulz]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Schroeder]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Baumert]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Caminal]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Methods derived from nonlinear dynamics for analysing heart rate variability]]></article-title>
<source><![CDATA[Phil Trans R Soc]]></source>
<year>2009</year>
<volume>367</volume>
<numero>1887</numero>
<issue>1887</issue>
<page-range>277-296</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Dynamical systems theory and ZIPF - Mandelbrot law applied to the development of a fetal monitoring diagnostic methodology]]></source>
<year></year>
<conf-name><![CDATA[XVIII FIGO World Congress of Gynecology And Obstetric]]></conf-name>
<conf-date>November 2006</conf-date>
<conf-loc>Kuala Lumpur </conf-loc>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Avilán]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ortiz]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nueva metodología física y matemática de evaluación del Holter]]></article-title>
<source><![CDATA[Rev Colomb Cardiol]]></source>
<year>2008</year>
<volume>15</volume>
<page-range>50-54</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ortiz]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ayala]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluación matemática de la dinámica cardíaca con la teoría de la probabilidad]]></article-title>
<source><![CDATA[Rev Mex Cardiol]]></source>
<year>2009</year>
<volume>20</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>183-189</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Entropía proporcional de los sistemas dinámicos cardiacos: predicciones físicas y matemáticas de la dinámica cardíaca de aplicación clínica]]></article-title>
<source><![CDATA[Rev Colomb Cardiol]]></source>
<year>2010</year>
<volume>17</volume>
<page-range>115-129</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Izasa]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Salazar]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<source><![CDATA[Entropía proporcional aplicada a la evolución de la dinámica cardíaca. Predicciones de aplicación clínica. La emergencia de los enfoques de la complejidad en América Latina. Tomo I. Comunidad Editora Latinoamericana]]></source>
<year>2015</year>
<page-range>247-264</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Proportional Entropy of the cardiac dynamics in CCU patients]]></source>
<year></year>
<conf-name><![CDATA[7th International Meeting Intensive Cardiac Care]]></conf-name>
<conf-date>2011</conf-date>
<conf-loc>Tel Aviv </conf-loc>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pineda]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Matiz]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Rozo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Enfermedad coronaria]]></source>
<year>2002</year>
<publisher-loc><![CDATA[Bogotá ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Kimpres Ltda]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kolmogorov]]></surname>
<given-names><![CDATA[AN]]></given-names>
</name>
</person-group>
<source><![CDATA[Foundations of the theory of probability]]></source>
<year>1950</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Chelsea Publishing Company]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feynman]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Leighton]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Sands]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Probabilidad. Física. Vol. 1]]></source>
<year>1998</year>
<edition>Primera edición</edition>
<page-range>1-16</page-range><publisher-loc><![CDATA[México ]]></publisher-loc>
<publisher-name><![CDATA[Addison-Wesley Iberoamericana, S. A.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matvéev]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Física molecular]]></source>
<year>1987</year>
<edition>Primera edición</edition>
<publisher-loc><![CDATA[Moscú ]]></publisher-loc>
<publisher-name><![CDATA[MIR]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tolman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Principles of statistical mechanics]]></source>
<year>1979</year>
<edition>Primera edición</edition>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Dover Publications]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Machta]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Entropy, information, and computation]]></article-title>
<source><![CDATA[Am J Phys]]></source>
<year>1999</year>
<volume>67</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1074-1077</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Denton]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
<name>
<surname><![CDATA[Diamond]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Helfant]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Karagueuzian]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fascinating rhythm: A primer on chaos theory and its applicat ion to cardiology]]></article-title>
<source><![CDATA[American Hear t Journal]]></source>
<year>1990</year>
<volume>120</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1419-40</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Braun]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kowallik]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Freking]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hadeler]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Kniffki]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Meesmann]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Demonstration of nonlinear components in heart rate variability of healthy persons]]></article-title>
<source><![CDATA[Am J Physiol]]></source>
<year>1998</year>
<volume>275</volume>
<page-range>H1577-H1584</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[GQ]]></given-names>
</name>
<name>
<surname><![CDATA[Arzeno]]></surname>
<given-names><![CDATA[NM]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[LL]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[DK]]></given-names>
</name>
<name>
<surname><![CDATA[Zheng]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[NQ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chaotic Signatures of Heart Rate Variability and Its Power Spectrum in Health, Aging and Heart Failure]]></article-title>
<source><![CDATA[PLoS ONE]]></source>
<year>2009</year>
<volume>4</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>e4323</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Guang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Gou]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Chi]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Fractal, entropic and chaotic approaches to complex physiological time series analysis: A critical appraisal]]></source>
<year></year>
<conf-name><![CDATA[31st Annual International Conference of the IEEE EMBS Minneapolis]]></conf-name>
<conf-date>2009</conf-date>
<conf-loc>Minnesota </conf-loc>
</nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feynman]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Leighton]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Sands]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Leyes de la Termodinámica. Física. Vol. 1]]></source>
<year>1998</year>
<edition>Primera edición</edition>
<page-range>1-19</page-range><publisher-loc><![CDATA[México ]]></publisher-loc>
<publisher-name><![CDATA[Addison-Wesley Iberoamericana, S.A.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bekenstein]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[La información en el Universo holográfico]]></article-title>
<source><![CDATA[Investigación y ciencia]]></source>
<year>Octu</year>
<month>br</month>
<day>e </day>
<page-range>36-43</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Melo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mendoza]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Correa]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mathematical-physical prediction of cardiac dynamics using the proportional entropy of dynamic systems]]></article-title>
<source><![CDATA[J. Med. Med. Sci.]]></source>
<year>2013</year>
<volume>4</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>370-381</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández-Rañada]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Introducción. Orden y Caos. Scientific American]]></source>
<year>1990</year>
<page-range>4 - 8</page-range><publisher-name><![CDATA[Prensa Científica S.A.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Crutchfield]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Between order and chaos]]></article-title>
<source><![CDATA[Nat Phys]]></source>
<year>2012</year>
<volume>8</volume>
<page-range>17-24</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
