SciELO - Scientific Electronic Library Online

 
vol.11 issue1ULTRAVIOLET RADIATION TO CONTROL BACTERIA IN OIL WELL INJECTION WATERSENSITIVITY ANALYSIS OF THE BACKPROJECTION IMAGING METHOD FOR SEISMIC EVENT LOCATION author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


CT&F - Ciencia, Tecnología y Futuro

Print version ISSN 0122-5383On-line version ISSN 2382-4581

Abstract

AUDIVET, Cinthia et al. EVALUATION OF PERFORMANCE AND EARLY DEGRADATION OF A 180.8 KWP ROOFTOP ON A GRID-CONNECTED PHOTOVOLTAIC SYSTEM IN A COLOMBIAN TROPICAL REGION ENVIRONMENT. C.T.F Cienc. Tecnol. Futuro [online]. 2021, vol.11, n.1, pp.11-20.  Epub Sep 28, 2021. ISSN 0122-5383.  https://doi.org/10.29047/01225383.254.

The use of renewable energy such as photovoltaic is growing. According to IRENA, these systems are one of the most dynamic generation technologies. The global photovoltaic market has grown rapidly between 2000 and 2016 at an annual average compound rate of 44%, from 0.8 GW to 291 GW. In Colombia, regions with high solar irradiation levels have been identified as emerging markets. The Government's plan is to increase the share of non-conventional energies in the energy matrix from 2% to 8% - 10%. However, the uncertainties associated with technology and sites specific degradation rates make it difficult to calculate accurate electricity generation efficiencies and predicting future performance and material degradation rates, and thus business models exhibit considerable deviations related to the real electricity generation rates. This work studies the performance and early degradation of a 180.8 kWp rooftop on grid connected photovoltaic system, installed in Barranquilla, Colombia. Two methods were used: i) estimation of solar conversion efficiency, and ii) visual inspection. The first method includes a cross analysis of climatic conditions, irradiance levels, and the generated energy downstream the inverters. The second method consists of periodical visual inspections of installed modules to check: discoloration, delamination, busbar corrosion, cracking of solar cell, glass breakage, anti-reflection coating and solder bond.

Keywords : PV systems performance; PV system early degradation.

        · abstract in Spanish     · text in English     · English ( pdf )