SciELO - Scientific Electronic Library Online

 
vol.25 número55Finite Element Modeling of Direct Transition from Concrete Pavement to Asphalt PavementSimplified Inverter-Based Generation Model for Protection and Short-Term Stability Studies in Electromagnetic Transient Resolution índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


TecnoLógicas

versão impressa ISSN 0123-7799versão On-line ISSN 2256-5337

Resumo

MACIAS, Astrid L.; RODRIGUEZ, Diana C.  e  MOLINA, Francisco J.. Design of Influent Distribution System in Domestic Wastewater Treatment Units. TecnoL. [online]. 2022, vol.25, n.55, e205.  Epub 02-Fev-2023. ISSN 0123-7799.  https://doi.org/10.22430/22565337.2428.

The efficient treatment of domestic wastewater is associated with good operational practices in wastewater treatment plants (WWTP) and the proper design of each treatment unit, which ensures the correct hydraulic performance of each WWTP. For this reason, the objective of this article was to study the design of the multiple influent distribution systems of a high-rate primary sedimentary, a UASB (Upflow Anaerobic Sludge Blanket) reactor, and an up-flow anaerobic filter (FAFA) in the WWTPs of the municipalities of San Carlos and San Roque, and in the township of Santiago, respectively, located in Antioquia-Colombia. For this purpose, the methodology proposed by Hudson in 1981 was used to evaluate the performance of the current design and, subsequently, a pre-dimensioning was carried out to distribute the flow uniformly, to have velocities within the ranges recommended by the literature, and to obtain the total head loss generated by the distribution manifold in each treatment unit evaluated. It was found that the existing design is not efficient and that the new pre-dimensioning ensures homogeneous flow distribution and provides velocities that contribute positively to the treatment process. The study concludes that the smaller the number of orifices and the larger the pipe diameter, the more uniform the flow distribution, and that the total head loss depends on both the velocity head and the head loss coefficient. The diameter of the orifice was the predominant parameter to control the inlet velocity of the treatment units.

Palavras-chave : Treatment plants; anaerobic reactors; primary settler; distribution system; wastewater treatment.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )