SciELO - Scientific Electronic Library Online

 
vol.19 número43Methodology for assessing the maturity of knowledge management in large companies some ColombianBolted join strength under parallel to grain double shear in guadua angustifolia structures índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Tecnura

versão impressa ISSN 0123-921X

Resumo

CRUZ HERNANDEZ, Ricardo Alfredo; PICO CORTES, Carlos Mauricio  e  PEREZ BUSTOS, Ludwing. Durability and acoustics of concrete with slag of cupola furnace as fine aggregate replacement. Tecnura [online]. 2015, vol.19, n.43, pp.37-45. ISSN 0123-921X.  https://doi.org/10.14483/udistrital.jour.tecnura.2015.1.a02.

In this paper, it was evaluated the performance of concrete with crushed slag of cupola furnace (SCF) as sand replacement in percentages of 0%, 10%, 15% and 20%, subjected to accelerated chemical attacks of carbonation, sulfation and alkali-aggregate reaction (AAR). The sound absorption characteristics of the material were determined through the sound absorption coefficient (α), and the noise reduction coefficient (NRC). Carbonation was evaluated through a closed camera with the 70% concentration of carbon dioxide and conditions of relative humidity between 50% and 70%. The results indicated that the penetration depth of CO2 is lower when greater the percentage of substitution is. To accelerate the attack by sulfates, specimens were immersed in aqueous solution of sodium sulfate anhydrous (Na2SO4) 1N with cycles of wetting and drying. It determined that the impairment presented in concrete paste is directly proportional to the percentage of sand replacement. The acceleration of the AAR in the concrete was carried out by immersing specimens in an aqueous solution of sodium hydroxide (NaOH) for 16 days. The test concluded that the inclusion of SCF is not favorable for AAR. The measurement of sound absorption coefficient was taken by the method of impedance tube, relating minimum and maximum values of stationary wave amplitude. The results showed that SCF with higher sand replacement are favorable for the noise absorption in buildings.

Palavras-chave : Alkali-aggregate reactions; carbonation; slag as fine aggregate; sound absorption coefficient; sulfation.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )